Preview only show first 10 pages with watermark. For full document please download

Oscilloscope

   EMBED


Share

Transcript

OSCILLOSCOPE Model OX 7104-C ➤ Five complementary tools in one: Oscilloscope, Multimeter, FFT Analyzer, Harmonic Analyzer and Recorder ➤ Sampling rate 1 GS/s in one-shot and 25 GS/s in ETS — memory depth of 2.5k per channel in “oscilloscope” mode ➤ Four independent, 8000-count, TRMS, 50kHz, digital multimeters ➤ Color LCD touch screen ➤ 33 direct command keys and “Windows-like” menus on screen ➤ Multi-interface communication connector: RS-232, Centronics and Ethernet with web server FEATURES ➤ Five complementary tools in one: Oscilloscope, Multimeter, FFT Analyzer, Harmonic Analyzer and Recorder ➤ Sampling rate 1 GS/s in one-shot and 25 GS/s in ETS – memory depth of 2.5k per channel in “oscilloscope” mode ➤ Four isolated measurement channels, 600V Cat III and up to eight curves on screen ➤ Real-time FFT analysis standard and calculation functions on the channels The Model OX 7104-C’s four independent TRMS digital multimeters and optional harmonic analyzer are ideal for industrial maintenance professionals. APPLICATIONS ➤ ➤ ➤ ➤ ➤ ➤ On-site contractor maintenance – industrial or electronic “Internal” plant maintenance Installations and start-up Industrial Process Quality control Research and laboratory – engineers or technicians ➤ Four independent, 8000-count, TRMS, 50kHz, digital multimeters ➤ Color LCD touch screen ➤ 33 direct command keys and “Windows-like” menus on screen ➤ Multi-interface communication connector: RS-232, Centronics and Ethernet with web server Model OX 7104-C includes metallic carrying case, adapter/line charger, NiMH battery pack, 1/10 Probix probe, one BNC Probix adapter, one Probix banana adapter, one set of 4mm banana cords, one crossed Ethernet cord and user manual. 2 www.aemc.com Technical Assistance (800) 343-1391 SPECIFICATIONS MODEL OX 7104-C INTERFACE Screen Specifications Display Mode No of Curves on Screen Front Panel Control Screen Control Languages VERTICAL Bandwidth Channels Input Impedance Maximum Permanent Input Voltage Vertical Sensibility Accuracy Vertical Zoom Probe Factors HORIZONTAL Time Base Speed Accuracy Horizontal Zoom TRIGGERING Mode Source Type Coupling Sensitivity DIGITAL MEMORY Maximum Sampling Speed Vertical Resolution Memory Capacity per Channel User Memory Other Modes XY Mode OTHER FUNCTIONS Autoset FFT Analyzer and Math Functions Cursors Automatic Measurements MULTIMETER AC, DC, AC + DC voltage Resistance Other Measurements RECORDER (option) Acquisition Rate Duration of Recording Acquisition Mode Operation HARMONIC ANALYZER (option) Analysis Span Operation GENERAL SPECIFICATIONS Configurations Memories Ethernet Network Printing (standard) RS-232 or Centronics (options) Communication Power Source Dimensions Weight Color 5 x 7" LCD (115 x 86mm) 320 x 240 – CCFL backlighting Vectors with interpolation Four curves and four references – Split screen and full screen modes (tracing zone 110 x 74) 32 direct shortcuts Touch screen - "Windows-like" menus and graphic commands Five complete languages, menus and on-line help (English, French, German, Spanish, Italian) Bandwidth 100Mhz Four isolated channels 1M ± 0.5% 600V Cat. III – Derating -20dB/decade at 100kHz 16 ranges from 2.5mV to 200V/div ±1.5% x5 maximum 1 / 10 / 100 / 1 000 or scaling to any value – Definition of the measurement unit 35 ranges from 1ns/div to 200s/div ±1.5% x10 maximum Auto, trigger, single, Auto 50% CH1, CH2, CH3, CH4 Front, pulse or delay (20ns/340s), count (2/16384) or TV (525 or 625 lines) AC, DC, HFR, LFR, noise reduction – Hold-off adjustable from 40ns to 1s 0.6 div to 1KHz / 1.5 div to 150MHz 25 GS/s in ETS - 1 GS/s in one-shot (on each channel) 12 bits “TRC” approx. 10kB, “TXT” approx. 20kB 1 MB Envelope mode (Factors from 2 to 64) Between two from the four curves – math functions and cursors Complete autoset at less than 3s, with recognition of channels – Frequency > 30Hz FT, + , - , x , / - Editor of mathematical functions Two or three cursors : V and T simultaneous or Phase Resolution 12 bits, display four digits 18 level or time measurements, phase measurements – Resolution 12 bits, display four digits From 400.0mV to 600.0VRMS or 800.0VDC - Accuracy VDC 0.5 % R+ 5D – bandwidth 50kHz 80.00 to 32.00M - Precision 0.5 % R+ 5D - Rapid 10-ms continuity test Capacities 5.000nF to 50.00mF/Frequency 200.0MHz - Diode test 3.3V Sampling interval from 500µs to 10mn From 25s to 34 days 16h 20mn Conditional on thresholds or windows – Normal or "50-faults" acquisition Timestamped graphic recording, conversion and units of physical quantities, measurement using cursors and search for events, standard file format usable in spreadsheets (.TXT) Even or odd orders up to 31, or first 16 orders Permanent display: total RMS value and harmonic factor – Order selected: % F, phase, freq, VRMS Unlimited - “.CFG” file size approx. 1kB 11 black and white or color drivers : IBM Proprinter, Epson ESC/P, Canon HP PCL, Seiko DPU411, Postscript Image files: “.BMP” 10kB, “.GIF” approx. 5kB (storage in memory transfer by RS-232 or Ethernet) Local via Ethernet 10 MB or RS 232 (option) - Remote via 10 MB Ethernet and web server “Sx-Metro” application software for PC (option) 9.6V/3.8 A/h battery pack - Approx. 4h between charges - Adjustable power-saving switching Multi-voltage 98-254V / 47-63Hz - Fast charge in 2 hours (oscilloscope off) 10.25 x 7.25 x 2" (261 x 185 x 53mm) 4.2 lbs (1.9kg with batteries) Technical Assistance (800) 343-1391 www.aemc.com 3 Recorder Multimeter The Model OX 7104-C manages a great variety of sensors (voltage, current, temperature, 0 to 10V, 4 to 20mA, etc) and displays the signals in their original physical magnitude (scale and unit). Automatic recording of the measure values in memory is performed on all active channels, making possible surveillance of a period lasting from 5 minutes to 24 hours. Oscilloscope Analyzer Actual triggering in the channel occurs after a delay of 35.2µs with respect to the auxiliary source. The result of the harmonic analysis is displayed in bargraph form. ORDERING INFORMATION CATALOG NO. Portable Oscilloscope Model OX 7104-CK (Four x 100MHz, Color – Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.54 Portable Oscilloscope Model OX 7104-CK (Four x 100MHz, Color – Power Kit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.63 Accessories (Optional) Software, Data Retrieval Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.70 Harmonic Analyzer, Firmware – upgrade on CD-ROM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.71 Recorder Function, Firmware – upgrade on CD-ROM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.72 PROBIX PRHX1, 1/10 Probe, 250MHz, 1000V Cat. II (600V Cat. III) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.73 PROBIX PRHX4, BNC Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.74 PROBIX PRHX5, 50Ω Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.75 PROBIX Banana Plug (4mm) Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.76 PROBIX Current Probe, 20mA to 20A, 100kHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.77 PROBIX PRH7, K thermocouple Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.78 Carrying Case, Aluminum with foam cut-outs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.79 Straight Ethernet Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.80 Crossed Ethernet Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.81 RS-232 Adapter/CENTRONICS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.82 RS-232 Cable/9-pin SUB-D cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.83 Set of two color-coded leads (1.5m) (black and red, 4mm straight, 4mm right angle) with color-coded safety alligator clips (black and red). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2124.84 Call the AEMC® Instruments Technical Assistance Hotline for immediate consultation with an applications engineer: (800) 343-1391 Chauvin Arnoux®, Inc. d.b.a AEMC® Instruments • 200 Foxborough Blvd. • Foxborough, MA 02035 USA • (800) 343-1391 • (508) 698-2115 • Fax (508) 698-2118 Visit our website at www.aemc.com 950.BR-OSCILLO 10/05 Printed in the USA