Preview only show first 10 pages with watermark. For full document please download

Outback Power Energycell Gh Data Sheet

   EMBED


Share

Transcript

EnergyCell GH Front Terminal Battery VRLA Battery for Grid/Hybrid Renewable Energy Storage • EnerSys SBS EON Technology for Higher Energy Density • Front Terminal Access for Ease of Installation and Maintenance • UL-Recognized Component • Designed for Grid/Hybrid and AC-Coupled Renewable Energy Storage Applications • Up to 4-Year Full Replacement Warranty • 18-Month Shelf Life @ 25°C • Wide Operating Temperature Range OutBack’s new EnergyCell Valve Regulated Lead Acid (VRLA) 200GH batteries are designed to support critical power applications in Grid/Hybrid systems where renewable sources normally augment grid power, but the power-conversion system switches to off-grid operation during emergencies or outages. EnerSys SBS EON technology incorporates TPPL AGM (Thin Plate Pure Lead Advanced Glass Mat) which allows for greater shelf life, extended float service life in optimal operating conditions, higher energy density, and superior discharge and charge performance. The EnergyCell GH battery series is designed for Grid/Hybrid and AC-coupled storage applications; for deep-cycle applications OutBack EnergyCell RE batteries are recommended. The EnergyCell GH also features front terminal access with threaded copper inserts, which decreases maintenance and increases safety. EON Technology is a trademark of EnerSys. www.outbackpower.com EnergyCell GH Front Terminal Battery Specifications EnergyCell 200GH EnergyCell 220GH 6 6 12 VDC 12 VDC Cells Per Unit Voltage Per Unit Operating Temperature Range (with temperature compensation) -40 to 122°F (-40 to 50°C) Optimal Operating Temp Range 68°F (20°C) Float Charging Voltage 13.62 VDC / unit average at 77°F (25°C) Equalization and Cycle Service Charging Limits 14.4 VDC / unit average at 77°F (25°C) Battery can be stored up to 18 months at 77°F (25°C) before a freshening charge is required. Batteries stored at temperatures greater than 77°F (25°C) will require recharge sooner than batteries stored at lower temperatures. Self Discharge Temp Compensation Factor (Charging) ±4mV per degree C per cell (2V) Terminal Threaded copper alloy insert terminal to accept ¼”-20 UNC bolt Terminal Hardware Initial Torque Weight M6 = 80 in-lbs (9.0 Nm) Float Life (Float @ 55ºC using recommended FV for 20ºC) Dimensions* (H x D x W) 120 116 lbs (53 kg) 132 lbs (60 kg) 11.1 x 22.1 x 4.9” (28.2 x 56.1 x 12.4 cm) 12.4 x 22.1 x 4.9” (31.5 x 56.1 x 12.4 cm) 110 Nominal Capacity (%) 100 * Batteries to be installed with 0.5 in (12.7 mm) spacing minimum and free air ventilation 90 80 d FV for 20ºC) 70 Ampere Hour Capacity to 1.75 Volts Per Cell at 77°F (25°C) 60 50 120 0 3 0 1 2 3 3 5 6 5 13 14 15 16 17 8 EnergyCell 220GH 133.5 12 176.4 198 166.2 20 191 214 173.2 24 189.6 216 159 1782.17 100 200 220 168.8 188.8 148.5 8 9 10 11 12 13 14 15 16 17 2.17 2.16 2.15 2.14 2.13 96 2.15 91 2.14 87 2.13 100 2.12 96 2.11 91 +40°C 87 2.10 0 83 2.12 79 2.11 74 +40°C 2.10 0 +30°C 6 +25°C 12 +20°C 16 24 +10°C 30 36 100 2.16 70 42 48 Approx. State of Charge (%) Open Circuit Voltages per Cell 12 EnergyCell 200GH 6 Months 83 +30°C +25°C 12 16 +20°C 24 Months +10°C 30 36 79 120 110 100 90 4280 70 60 50 74 70 48 Approx. State of Charge (%) 11 0ºC) Discharge in Hours 154.8 7 Calculated Life (years @ 20ºC) 4 EnergyCell 220GH Open Circuit Voltages per Cell 1 EnergyCell 200GH 20 10 Nominal Capacity (%) 40 Discharge in Hours 30 Float Life (Float @ 55ºC using recommended FV for 20ºC) 40 30 20 10 0 0 1 2 3 3 5 6 7 8 9 10 11 12 13 14 15 16 17 Calculated Life (years @ 20ºC) Cycle Life vs Depth of Discharge Campare Float Charge (EnergyCell GH) EnergyCell GH Float Charge 1000 Open Circuit Voltages per Cell vs Depth of Discharge at Charge (EnergyCell GH) Number of Cycles 10000 Available From: EnergyCell GH Float Charge 100 0 10 20 30 40 50 60 70 80 90 100 110 120 Depth of Discharge 60 70 80 90 100 110 120 www.outbackpower.com Asia Office: Suite 1903, Tower 1, China Hong Kong City 10000 33 Canton Road, Kowloon Hong Kong 1000 Phone: +852 2736 8663 Fax: +852 2199 7988 Number of Cycles European Office: Hansastrasse 8 D-91126 Schwabach, Germany Phone: +49 9122 79889 0 Fax: +49 9122 79889 21 2.16 2.15 2.14 2.13 2.12 2.11 +40°C YOUR Khd<WKtZDISTRIBUTOR 2.10 SOLIGENT 0 800-967-6917 www.soligent.net h of Discharge Corporate Office: 17825 59th Ave. NE, Suite B Arlington, WA 98223 USA Phone: +1 360 435 6030 Fax: +1 360 435 6019 2.17 100 0 10 20 LatinCycle American Office: Life vs Depth of Discharge Campare Float Charge (EnergyCell GH) 15105 Cedar Bluff Pl. Wellington, FL 33414 USA Phone: +1 561 792 9651 Fax: +1 561 792 7157 30 40 50 60 70 Depth of Discharge 80 90 +30°C 6 EnergyCell GH Float Charge 100 120 6/13 110