Transcript
Outdoor and Indoor Dome Housings Installation and Operation Instructions for the following models: UNI-ONS7C1 Outdoor Pendant Housing w/ heater & blower, clear lower dome, 24Vac input UNI-ONS7T1 Outdoor Pendant Housing w/ heater & blower, tinted lower dome, 24Vac input UNI-ONS7C1W Outdoor Pendant Housing w/ heater & blower, clear lower dome, and a Wireless antenna cable (antenna mast not included), 24Vac input UNI-ONS7T1W Outdoor Pendant Housing w/ heater & blower, tinted lower dome, and a Wireless antenna cable (antenna mast not included), 24Vac input UNI-INS7C1 Indoor Pendant Housing without heater & blower, clear lower dome, 24Vac input UNI-INS7T1 Indoor Pendant Housing without heater & blower, tinted lower dome, 24Vac input UNI-INS7C3 Indoor Pendant Housing without heater & blower, clear lower dome, 12Vdc input UNI-INS7T3 Indoor Pendant Housing without heater & blower, tinted lower dome, 12Vdc input Note: AC 24V power supply for the camera and the heater/blower is an installer/reseller provided item Please refer to page 2 Electrical Specifications for power consumption details. Indoor models Mounting instructions for: a) SNC-RZ30, please refer to page 3 b) SNC-RZ50, please refer to page 4
Supplied Parts (1) 4-pin Power connector (1) RJ-45 coupling (Outdoor Models only) (2) 1/4-20 hex head screws (2) Spacer (2) Locknut (4) 3x8mm Philips head screws (1) 4-pin Auxiliary connector (Outdoor Models only) (1) Installation/assembly Manual (4) Threaded aluminum standoffs (for use with SNC-RZ50 only) (1) 2ft. Wireless antenna cable (Wireless models only) (1) Pre-installed cable with MMCX to N Connector
2/28/06
-1-
81-IN6582
ELECTRICAL SPECIFICATIONS (OUTDOOR ONLY): UNI-ONS7C1 & UNI-ONS7T1
!
2. Open the housing assembly box. Note there is a small roll of Teflon Tape that will be needed during installation, put it aside. (Picture 2) Teflon Tape
Power 24VAC, Class 2 Only
26 watts at 24 VAC (Heater and Blower) Heater: 25 watts Blower: 1 watt 25 watts at 24 VAC (Camera) Input Connectors (outdoor units): (1) BNC (Analog Video) (2) screw-down connectors (power & alarms) (1) RJ45 (Data)
(INDOOR ONLY - POWERED): UNI-INS7C1 & UNI-INS7T1
!
Power 24VAC, Class 2 Only
Picture 2
3, Open the dome assembly box. Note there is a protection film on the dome. DO NOT REMOVE the film until the product is fully assembled and installed. This film protects the dome from scratches during installation. (Picture 3)
25 watts at 24 VAC (Camera) Input Connectors (outdoor units): (1) BNC (Analog Video) (2) screw-down connectors (power & alarms) (1) RJ45 (Data)
(INDOOR ONLY): UNI-INS7C3 & UNI-INS7T3
!
Power 12Vdc, Class 2 Only
See camera instructions for details. No Input Connectors: (All wiring is to be run directly to the camera. Please follow camera installation instructions.)
GENERAL INSTRUCTIONS:
Picture 3 4. There is a safety lanyard that is attached to the inside of the dome assembly. Take the open end of the lanyard and loop it around the lanyard tab that is located inside the housing top. (Picture 4)
Tools Required: .100" Flat Head Screwdriver Phillips Head Screwdriver
ASSEMBLING THE PRODUCT: 1. Remove the contents of the box onto a table. The larger subassembly box is the housing assembly. The smaller subassembly box is the dome assembly. (Picture 1) Picture 1
Picture 4 5. The safety lanyard is now attached to the housing (Picture 5).
-2-
Picture 5
INSTALLING QUICK RELEASE BRACKETS
Orient the camera onto the quick release bracket as shown in this illustration:
SNC-RZ30 Steps: a) Install the Sony SNCRZ30N pan/tilt onto the quick release bracket using the 1/4-20 bolt and washer provided with the kit (Figure 1).
Use this hole
Figure 2
b) Place the Sony SNCRZ30N pan/tilt and quick release bracket in the housing, sliding the three open screw slots over the screws in the housing. Slide the bracket forward, then tighten the captive screw on the bracket (Figure 3).
Figure 1
Figure 1a
Figure 3
-3-
INSTALLING QUICK RELEASE BRACKETS SNC-RZ50 Steps: a) Attach camera to the quick release plate using (2) 3M Phillips head screws, and (1) ¼ -20 bolt and washer (Figure 1).
Use ¼-20 bolt and washers
Figure 2 Figure 1
b) Remove the (3) screws that are on the outside of the base plate. Then Thread on the (4) 1” aluminum spacers into the thread inserts that are located around the base plate. Re-attach the (3) Phillips head screws to (3) of the spacers (Figure 2).
c) Insert camera assembly into the housing and attach the quick release plate to the top of the 4 aluminum spacers. Slide the camera assembly forward and then tighten down the (3) Phillips head screws and the captive screw that is located on the quick release plate (Figure 3).
Figure 3
-4-
Power Connections (Inside of housing)
Wiring Color Code Control Inputs (Outside of housing)
POWER AND CONTROL LEADS
CONTROL
1
Camera Power (24 VAC)
Red
2
Camera Power (24 VAC)
Orange
1
Alarm 1
Blue
1
Alarm 1
Blue
2
Alarm 2
Violet
2
Alarm 2
Violet
3
Alarm 3
Gray
3
Alarm 3
Gray
4
Common
White
4
Common
White
The unit is set up with (2) individual power inputs. 1. Accessory Power (yellow and green wire) 2. Camera Power (red and orange) If you wish to provide a single power transformer it is recommended that: 1. Be certain that you know the total power consumption of the housing Heater (25 watts) + Blower (1 watt) + camera pan/tilt (25 watts) 2. Check the supplied wiring chart to be sure that you have the proper gauge wire for the distance that you intend to run your power wires. 3. Bring power to the 3 and 4 position of the power connector (yellow and green wire) 4. Jumper from the 1st position to the 3rd position and from the 2nd position to the 4th position of the terminal block. Be careful not to short between the yellow and green wires. (Please see figure below)
CAMERA POWER Plug in power with the provided right angle power plug.
12DC
–
Make all connections to the camera.
WIRING INSTRUCTIONS (INDOOR - NO POWER): UNI-INS7C3 & UNI-INS7T3:
24V AC Wiring Distances The following are the recommended maximum distances for 24 VAC with a 10% voltage drop (10% is generally the maximum allowable voltage drop for AC powered devices).
1. There are no pre-run cables on the indoor models. All wiring should be feed through the top of the housing and connected directly to the camera. 2. For wiring connections, follow the instructions that are included with the camera.
Wire Gauge Total vA consumed
WIRING INSTRUCTIONS (ALL MODELS EXCEPT INDOOR - NO POWER, "C3" or "T3"): RJ45
BNC (Large) Power (Small) Alarms
Wiring Color Code Power Inputs (Outside of housing) POWER 1
Camera Power (24 VAC)
Red
2
Camera Power (24 VAC)
Orange
3
Heater and Blower Power (24 VAC)
Yellow
4
Heater and Blower Power (24 VAC)
Green
5.5 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 AC 180 24V 190 Power Supply 200 Side
20 18 22 250 400 600 120 180 300 89 141 225 90 130 65 70 112 44 56 90 35 47 75 29 40 64 25 34 55 31 31 50 19 28 45 17 Add 2 jumpers for 41 16 single 25 power input 23 37 14 21 34 13 20 32 12 18 30 11 17 28 11 16 26 10 15 25 9 14 23 9 14 22 8
Maximum distance from transformer to load Maximum distance from transformer to load
+
16 14 12 10 960 480 800 1300 358 571 905 1440 225 350 525 830 179 285 452 720 143 228 362 576 119 190 301 480 102 163 258 411 85 140 215 340 79 126 201 320 71 114 181 Green 288 65 103 164 261Yellow Wires from 59 Dome 95 150 240 55 87 139 221 51 81 129 205 47 76 120 192 44 71 113 180 42 67 106 169 39 63 100 160 37 60 95 Orange 151 35 57 90 144 Red
NOTE: The total power consumption for the heater and blower, PLUS the camera you choose, need to be added together.
-5-
In this example, a 60VA AC24V is required.
FOR WIRELESS MODELS: UNI-ONS7C1W, UNI-ONS7T1W
4. Connect one end of the 2 ft cable to the top of the housing. Push down onto the connector and then thread on the connector until it is hand tight. (Picture 4)
1. This product includes an antenna cable, which must be used with the SNCA-CFW1 wireless card and the SNCA-AN1 antenna. After you have installed the SNCA-CFW1 wireless card into the camera (please refer to product manual for details) you can connect the antenna cable to the card. Inside the dome is a cable with a MMCX connector which will plug right into SNCA-CFW1 wireless card. Push the connector straight into the card. (Picture 1)
Picture 4
MMCX
Picture 1 2. On the top of the housing is an N style connector. (Picture 2)
Picture 2
N Connector
5. Connect the other end of the 2 ft cable to the SNCA-AN1 antenna. Follow the instructions that came with the SNCAAN1 on how to mount the antenna. (Picture 5) Please note that antenna mast (no more than 1.25" diameter) is an installer/user provided item. Picture below shows the SNCA-AN1 and its mounting hardware.
3. Inside the box that the housing came in is a 2 ft cable that will be used to connect the housing to the SNCA-AN1 antenna. (Picture 3)
Picture 5
Picture 3
-6-
INSTALLING THE HOUSING ASSEMBLY:
!
REMOVING AND ATTACHING THE DOME ASSEMBLY:
Be sure the bracket is properly and securely mounted to a supporting structure capable of rigidly holding the weight of the entire unit.
1. Attach the dome assembly to the housing top by lining up the arrow on the dome assembly with the left arrow on the housing top. Insert the dome assembly into the housing and then rotate the dome assembly clockwise until the dome assembly’s arrow lines up with the arrow that has the word locked above it. Then tighten the (3) screws on the front of the dome assembly.
NOTE: This unit is designed for operation in an upright position. Installing the product upside down may cause damage to the internal equipment, and will void the warranty. 1. This unit includes a 1½" NPT housing for a standard 1½" NPT pipe. The housing can be used with other brackets designed with 1½" male pipe threads, such as the UNI-WMB1 wall mount brackets. 2. Attach the housing coupling (Figure 3). NOTE: Pipe threads should be clean and rust free. Use the Teflon™ tape included with the housing on the threads.
Add thread sealing tape
Figure 3
3. Mount the housing assembly to the mounting bracket and housing coupling. A safety cable is included with the housing to temporarily hold it while making wiring connections. Loop the safety cable over one of the set screws on the housing coupling and make the appropriate connections using the (2) screw-down connectors supplied. 2. Remove the protective film from the dome. 2. Undo the safety cable and twist the housing onto the housing coupling. Secure all (3) setscrews provided on the housing coupling (Figure 4).
3. Clean the outside of the dome.
Set screws
Figure 4
-7-
Exploded View for Replacement Parts
16
9
8 4 7 6
5
3 2 1
-8-
Replacement Parts List
Part Number
Description
1
RPFD701
LOWER TRIM RING
2
FD7T
TINTED REPLACEMENT CAPSULE
FD7C
CLEAR REPLACEMENT CAPSULE
3
RPFD703
DOME CLAMPING BRACKET
4
RPFD072
24 VAC HEATER
5
RPFD080
(12 VDC) BLOWER (USER IN 24V HOUSINGS)
6
RPFD060
CAMERA BRACKET
7
RPRH707
CONNECTION PCB
8
RPFD040
HOUSING HARDWARE
9
RPFD709
HOUSING TOP
16
RPFD711W
PENDANT MOUNT BRACKET
-9-
IMPORTANT SAFEGUARDS 1
SAFETY PRECAUTIONS
Read Instructions - All the safety and operating instructions should be read before the unit is operated.
2
Retain Instructions - The safety and operating instructions should be retained for future reference.
3
Heed Warnings - All warnings on the unit and in the operating instructions should be adhered to.
4
Follow Instructions - All operating and user instructions should be followed.
5
Electrical Connections - Only a qualified electrician should make electrical connections..
6
Attachments - Do not use attachments not recommended by the product manufacturer as they may cause hazards.
7
Cable Runs - All cable runs must be within permissible distance
8
Mounting - This unit must be properly and securely mounted to a supporting structure capable of sustaining the weight of the unit.
C A UT I ON RISK OF ELECTRIC SHOCK DO NOT OPEN
!
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
The lightning flash with an arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of non-insulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
!
Accordingly: a. The installation should be made by a qualified installer.
The exclamation point within an equilateral triangle is intended to alert the user to presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
UNPACKING
b. The installation should be in compliance with local codes. c. Care should be exercised to select suitable hardware to install the unit, taking into account both the composition of the mounting surface and the weight of the unit.
Unpack carefully. Electronic components can be damaged if improperly handled or dropped. If an item appears to have been damaged in shipment, replace it properly in its carton and notify the shipper. Be sure to save:
Be sure to periodically examine the unit and the supporting structure to make sure that the integrity of the installation is intact. Failure to comply with the foregoing could result in the unit separating from the support structure and falling, with resultant damages or injury to anyone or anything struck by the falling unit.
1
The shipping carton and packaging material. They are the safest material in which to make future shipments of the equipment.
2
These Installation and Operating Instructions.
SERVICE If technical support or service is needed, contact Sony at the following number: TECHNICAL SUPPORT 8:15AM to 7:30PM (Eastern Time) 1-800-883-6817
©2006 Sony Corporation
- 10 -