Outdoor Housing PIH-510 H/L/G & 510 H/L/G IP
MERIT LILIN ENT. CO., LTD http://www.meritlilin.com
66-510CSE
INSTRUCTION MANUAL
IMPORTANT SAFEGUARDS 1. Read Instructions All the safety and operating instructions should be read before the unit is operated. 2. Retain Instructions The safety and operating instructions should be retained for future reference. 3. Head Warnings All warnings on the unit and in the operating instructions should be adhered to. 4. Follow Instructions All operating and user instructions should be followed. 5. Electrical Connections Only a qualified electrician should make electrical connections. 6. Attachments Do not use attachments not recommended by the product manufacturer as they may cause hazards. 7. Cable Runs All cable runs must be within permissible distance. 8. Mounting This unit must be properly and securely mounted to a supporting structure capable of sustaining the weight of the unit.
SAFETY PRECAUTIONS
CAUTION RISK OF ELECTRIC SHOCK
CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT OPEN COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the unit.
UNPACKING Unpack carefully. Electronic components can be damaged if improperly handled or dropped. If an item appears to have been damaged in shipment, replace it properly in its carton and notify the shipper. Be sure to save: 1. The shipping carton and packaging material. They are the safest material in which to make future shipments of the equipment. 2. This Installation and Operating Instruction.
SERVICE If the unit ever needs repair service, the customer should contact our dealer or branch for authorization to return and shipping instructions.
INSTALLATION Step 1
Separate The Housing and PSU Box
Untighten the screws from PSU box
Step 2
Untighten and pull out Separate the housing the bolt from the hinge and PSU box
Untighten the screws from PSU box and open it. (Swan Neck)
Install Power Supply Unit
When use 24Vac power source:
Tighten 2 screws to fix the PSU
Put the PSU into the box
When use 90~260Vac power source:
Put PSU into the box
Put the clamp on PSU
1
Tighten 2 screws to fix the PSU
Step 3
Install the Power Box 8 10
45
70
50.8 70
Drill 4 holes on desired locations
Step 4
Tighten 4 screws to fix the power box (These four screws are not supplied. User must prepare their own screws.)
50.8
Drill holes on the intended positions of of the wall. (Goose Neck)
Connection
Outdoor Housing Connection RS-485 Alarm In
Alarm Output
GND NO NC COM 6 5 4 3 2 1
GND TXDOTXDO+ TXDITXDI+
DC12V Input
VideoOutput
Fan&Heater FastDome Wiring Wiring
ACOutput
ACInput
1. Connect AC / DC cables:
Untighten the left knob, put the AC power cable through the hole and tighten the knob
Connect the AC power cable to AC Input jack
Connect the AC power cable(below) to AC Output jack
2
Connect the DC power cable(above) to DC Input jack
2. Connect Video cable:
Connect the video cable to output jack
Untighten the middle knob, put the video cable through the hole and tighten the knob
3. Connect Alarm, telemetry control (RS-485) and Video cables:
Untighten the right knob, put the Alarm and RS-485 cables through the hole and tighten the knob
Connect the telemetry control (RS-485) to RS-485 Input (TXDI+,TXDI-)
Connect the Alarm input cable to Alarm Input (Alarm 1 & GND)
CAUTION * For better waterproofing, please use one cable with one knob only. (Recommended) * When using two cables with one knob, please fill the seam between cables with waterproof glu to make it waterproof.
Cable diameter for the knob : 5~12mm 3
Outdoor Housing for IP Series Connection RS-485
Alarm In Alarm Output GND NO NC COM 6 5 4 3 2 1
GND TXDOTXDO+ TXDITXDI+
RJ-45 DC12V Input VideoOutput
Fan&Heater Wiring
FastDomeWiring
ACOutput
ACInput
1. Connect AC / DC cables:
Untighten the left knob, put the AC power cable through the hole and tighten the knob
Connect the AC power cable to AC Input jack
Connect the AC power cable(below) to AC Output jack
Connect the DC power cable(above) to DC Input jack
2. Connect RJ-45 and Video cables:
Untighten the middle knob, put the video and RJ-45 cables through the hole and tighten the knob
Connect the video cable to output jack
4
Connect the network cable to RJ-45 jack
3. Connect Alarm, RS-485, cables:
Untighten the right knob, put the Alarm and RS-485 cables through the hole and tighten the knob
Connect the telemetry control (RS-485) to RS-485 Input (TXDI+,TXDI-)
Connect the Alarm input cable to Alarm Input (Alarm 1 & GND)
CAUTION * For better waterproofing, please use one cable with one knob only. (Recommended) * When using two cables with one knob, please fill the seam between cables with waterproof glu to make it waterproof.
Cable diameter for the knob : 5~12mm
Step 5
Attach the Base to Housing
Turn the dome cover anti-clockwise
Separate the dome cover from camera
5
Untighten the 3 screws from base
Turn the camera body anti-clockwise
Separate the camera body and base
Unplug the connection cable
Attach the base to housing
Connect the housing cable
Tighten 3 screws to fix base
Step 6
Camera Setting Setting Fast Dome ID Setting Alarm Mode Setting Camera Function Setting Fan Power Refer to FastDome operation manual for camera setting
Step 7
Attach Camera Body and Base
Reconnect the connection cable
Attach camera body to base
Turn camera body clockwise to high position
6
Tighten the three screws to fix the camera body
Step 8
Install The Dome Cover and Housing Cover
Attach the dome cover to camera
Step 9
Turn the dome cover clockwise to tight position
Attach the cover to housing
Tighten the 3 screws to fix the cover
Attach PSU and Bracket
Attach the housing back to PSU box
Insert the bolt into the hinge and tighten
Step 10 Connection Between Housing and FastDome
Connect the fan & heater cable to pin jack
Connect the Fast Dome cable to connection jack
7
Step 11
Install the Power Box, Bracket and Housing
Pendant
Attach the bracket and housing to the box
Tighten the 4 screws to fix the bracket
Wall Mounting
Attach the bracket and housing to the box
Tighten the 4 screws to fix the bracket
Swan Neck
Tighten the screws of PSU box to fix the cover.
8
STRUCTURAL DRAWING Wall Mounting
Pendant 274
70
70
204
477.5
367.2 312.5
270 270
405
Swan Neck 500
225
320 650
270 200
685
Unit: MM 9
WIRING DIAGRAM Outdoor Housing
Connect to Heater and Fan
DC12V OUT
SWITCH POWER AC90~260V
or
SWITCH POWER AC24V
TXDI+ TXDITXDO+ TXDOGND
Connect to FastDome LINE NEUTRAL
DC12V IN
ALARM IN
GND AC-OUT GND
ALARM OUT
NEUTRAL
1 2 3 4 5 6 COM NC NO GND
LINE
NEUTRAL
GND
LINE
AC-IN AC24V
AC-IN 24Vac
VIDEO OUT
TO NEXT FastDome
TO Keyboard
Outdoor Housing for IP Series
Connect to Heater and Fan
DC12V OUT
SWITCH POWER AC24V
Connect to FastDome LINE NEUTRAL
TXDI+ TXDITXDO+ TXDOGND ALARM IN
GND AC-OUT GND
ALARM OUT
NEUTRAL
1 2 3 4 5 6 COM NC NO GND
LINE
LINE
NEUTRAL
or
GND
SWITCH POWER AC90~260V
DC12V IN
TO IP AC-IN AC24V
AC-IN 24Vac
10
VIDEO OUT
TO TO NEXT FastDome Keyboard
SPECIFICATION Outdoor Housing Model No. Type
PIH-510 L PIH-510 G PIH-510 H Pendant Wall Mounting Swan Neck Brocket Aluminum Top Flame Resistant ABS Construction Internal Fixing Steel Housing Polycarbonate Input Voltage DC12V Connection Current Consumption 700mA (Fan + Heater) PCB RS-485 RS-485 In (2 inputs) RS-485 Out (2 outputs) Alarm Alarm-In (6 inputs) Alarm-Out (3 outputs) On +15 C OFF +25 C Heater Activation Fan Activation On +35 C OFF +25 C 270mm( f ) x 297.5mm(H) Dimension Weight 5Kg 4.8Kg 10Kg
Outdoor Housing for IP Series PIH-510 G PIH-510 L PIH-510 H Pendant Wall Mounting Swan Neck Brocket Aluminum Top Flame Resistant ABS Construction Internal Fixing Steel Housing Polycarbonate Input Voltage DC12V Current Consumption 700mA (Fan + Heater) Connection RS-485 RS-485 In (2 inputs) RS-485 Out (2 outputs) PCB RJ-45 One RJ-45 for Ethernet (10 Base-T) Alarm Alarm-In (6 inputs) Alarm-Out (3 outputs) On +15 C OFF +25 C Heater Activation Fan Activation On +35 C OFF +25 C 270mm( f ) x 297.5mm(H) Dimension Weight 10Kg 5Kg 4.8Kg Model No. Type
11
66-510CSE-5
Outdoor Housing PIH-510 H/L//G & 510 H/L/G IP
MERIT LILIN ENT. CO., LTD http://www.meritlilin.com
66-510CSE
INSTRUCTION MANUAL