Preview only show first 10 pages with watermark. For full document please download

Overloads Datasheet

   EMBED


Share

Transcript

Overload Relays Specifications GT12 GT32 GT63 GT95 Electrical characteristics of power circuit 12AF 32AF GT125 GT32S GT63S GT63L GT95S GT95L 10 Screw clamp 3 Up to 690V 690V 6kV 0.1~12A IP 20 -5 ~ +40 10 Screw clamp 3 Up to 690V 690V 6kV 0.1~32A IP 20 -5 ~ +40 10 Screw clamp 3 Up to 690V 690V 6kV 4~65A IP 20 -5 ~ +40 10 Lug 3 Up to 690V 690V 6kV 4~65A IP 20 -5 ~ +40 10 Screw clamp 3 Up to 690V 690V 6kV 7~95A IP 20 -5 ~ +40 10 Lug 3 Up to 690V 690V 6kV 7~95A IP 20 -5 ~ +40 ● ● ● ● GC-9, 12 ● ● ● ● GC-18, 25, 32 Type Relay type Differential type (Phase failure protection) Tripping class(IEC 60947-4-1) Terminal type Number of poles Rated operational voltage (Ue) Rated insulation voltage (Ui) Rated impulse voltage (Uimp) Setting range Degree of protection (IEC 60 529) Temperature compensation (°C) Functions Trip indicating Stop Test Manual/Automatic Reset Applied contactors Note) Detail setting range and connection cable 63AF 95AF ● ● ● ● ● ● ● ● GC-35, 40, 50, 63 ● ● ● ● ● ● ● ● GC-65, 75, 85, 95 is rated current. 12AF 32AF 63AF 95AF Class 12AF 32AF ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 63AF ● ● ● ● ● ● ● ● ● ● ● ● ● 95AF ● ● ● ● ● ● ● ● ● ● ● ● ● Current Wire Setting Size Type range(A) mm2 AWG 0.1~0.16 0.16~0.25 0.25~0.4 0.4~0.63 0.63~1 1 18 1~1.6 1.6~2.5 2.5~4 4~6 5~8 6~9 65/75°C 1~1.5 18 ~16 7~10 Cu-wire 9~13 1.5~2.5 16~14 only 12~18 2.5 14~12 16~22 2.5~4 12~10 18~25 22~32 4~6 10 24~36 4~10 10~8 28~40 6~10 10~8 34~50 10 8 45~65 10~16 8~6 54~75 16~25 6~4 63~85 70~95 25~35 4~3 Max. number of conductors Short circuit "r " - 1kA 2 3kA 5kA B-2-2 MIDI-cat2008.indd 2 11/21/08 10:14:52 AM Charactoristics Class 10A Overload Relays Characteristics class 10A differential 3 heater type for direct mounting beneath contactors with connection by screw clamp terminals GT12S GT32S Corresponding Contactors Type GC9S GC12S GC18S GC25S GC32S Relay Setting Range A 0.1~0.16 0.16~0.25 0.25~0.4 0.4~0.63 0.63~1 1~1.6 1.6~2.5 2.5~4 4~6 5~8 6~9 7~10 9~13 0.1~0.16 0.16~0.25 0.25~0.4 0.4~0.63 0.63~1 1~1.6 1.6~2.5 2.5~4 4~6 5~8 6~9 7~10 9~13 12~18 16~22 18~25 22~32 Relay Types Weight Differential 3 Heaters kg GT12S0.16A GT12S0.25A GT12S0.4A GT12S0.63A GT12S1A GT12S1.6A GT12S2.5A 0.1 GT12S4A GT12S6A GT12S8A GT12S9A GT12S10A GT12S13A GT32S0.16A GT32S0.25A GT32S0.4A GT32S0.63A GT32S1A GT32S1.6A GT32S2.5A GT32S4A GT32S6A 0.17 GT32S8A GT32S9A GT32S10A GT32S13A GT32S18A GT32S22A GT32S25A GT32S32A Accessories Separate mounting adapters and remote reset unit : see pages B-2-7 to B-2-8 Mounting Direct mounting on to a contactor with screw clamp terminals B-2-3 MIDI-cat2008.indd 3 9/19/08 7:57:51 PM Charactoristics Class 20A Overload Relays Characteristics class 10A differential 3 heater type for direct mounting beneath contactors with connection by lug terminals GT63L GT95L Corresponding Contactors Type GC35L GC40L GC50L GC63L GC65L GC75L GC85L GC95L Relay Setting Range A 4~6 5~8 6~9 7~10 9~13 12~18 16~22 18~25 24~36 28~40 34~50 45~65 7~10 9~13 12~ 18 16~22 18~25 24~36 28~40 34~50 45~65 54~75 63~85 70~95 Relay Type Differential 3 Heaters GT63L6A GT63L8A GT63L9A GT63L10A GT63L13A GT63L18A GT63L22A GT63L25A GT63L36A GT63L40A GT63L50A GT63L65A GT95L10A GT95L13A GT95L18A GT95L22A GT95L25A GT95L36A GT95L40A GT95L50A GT95L65A GT95L75A GT95L85A GT95L95A Accessories Separate mounting adapters and remote reset unit : see pages B-2-7 to B-2-8 Mounting Direct mounting on to a contactor with lug terminals B-2-5 Weight Kg 0.33 0.50 Overload Relays Characteristics class 10A differential 3 heater type for direct mounting beneath contactors with connection by screw clamp terminals GT63S GT95S Corresponding Contactors Type GC35S GC40S GC50S GC63S GC65S GC75S GC85S GC95S Relay Setting Range A 4~6 5~8 6~9 7~10 9~13 12~18 16~22 18~25 24~36 28~40 34~50 45~65 7~10 9~13 12~18 16~22 18~25 24~36 28~40 34~50 45~65 54~75 63~85 70~95 Relay Types Differential 3 Heaters GT63S6A GT63S8A GT63S9A GT63S10A GT63S13A GT63S18A GT63S22A GT63S25A GT63S36A GT63S40A GT63S50A GT63S65A GT95S10A GT95S13A GT95S18A GT95S22A GT95S25A GT95S36A GT95S40A GT9550A GT9565A GT95S75A GT95S85A GT95S95A Weight kg 0.31 0.48 Accessories Separate mounting adapters and remote reset unit : see pages B-2-7 to B-2-8 Mounting Direct mounting on to a contactor with screw clamp terminals B-2-4 MIDI-cat2008.indd 4 9/19/08 7:57:52 PM Tripping Charactoristics Overload Relays Tripping characteristics Cold starting GT32 60 40 30 Minute 20 10 8 6 5 4 3 Tripping Time 2 60 40 30 20 Second 10 8 6 5 4 GT32 3 2 1 0.8 0.6 0.5 0.4 0.3 1 2 3 4 5 Multiple of current setting 6 7 8 9 10 15 x In[A] B-2-9 MIDI-cat2008.indd 9 9/19/08 7:57:54 PM Overload Relays Tripping characteristics Hot starting GT32 60 40 30 Minute 20 10 8 6 5 4 3 Tripping Time 2 60 40 30 20 Second 10 8 6 5 4 3 2 GT32 1 0.8 0.6 0.5 0.4 0.3 1 2 3 4 5 Multiple of current setting 6 7 8 9 10 15 x In[A] B-2-10 MIDI-cat2008.indd 10 9/19/08 7:57:54 PM Overload Relays Tripping characteristics Cold starting GT63 60 40 30 Minute 20 10 8 6 5 4 3 Tripping Time 2 60 40 30 20 Second 10 8 6 5 4 GT63 3 2 1 0.8 0.6 0.5 0.4 0.3 1 2 3 4 5 Multiple of current setting 6 7 8 9 10 15 x In[A] B-2-11 MIDI-cat2008.indd 11 9/19/08 7:57:54 PM Overload Relays Tripping characteristics Hot starting GT63 60 40 30 Minute 20 10 8 6 5 4 3 Tripping Time 2 60 40 30 20 Second 10 8 6 5 4 3 GT63 2 1 0.8 0.6 0.5 0.4 0.3 1 2 3 4 5 Multiple of current setting 6 7 8 9 10 15 x In[A] B-2-12 MIDI-cat2008.indd 12 9/19/08 7:57:55 PM Overload Relays Tripping characteristics Cold starting GT95 60 40 30 Minute 20 10 8 6 5 4 3 Tripping Time 2 60 40 30 20 Second 10 8 6 5 4 GT95 3 2 1 0.8 0.6 0.5 0.4 0.3 1 2 3 4 5 Multiple of current setting 6 7 8 9 10 15 x In[A] B-2-13 MIDI-cat2008.indd 13 9/19/08 7:57:55 PM Overload Relays Tripping characteristics Hot starting GT95 60 40 30 Minute 20 10 8 6 5 4 3 Tripping Time 2 60 40 30 20 Second 10 8 6 5 4 3 GT95 2 1 0.8 0.6 0.5 0.4 0.3 1 2 3 4 5 Multiple of current setting 6 7 8 9 10 15 x In[A] B-2-14 MIDI-cat2008.indd 14 9/19/08 7:57:55 PM Overload Relays (Screw Type) Overall Dimensions Overload relays GT-12S Overload relays 3.7 [mm] 86.3 66 74.6 17.5 GT-32S M3.5 (Aux terminal) M4 (Main terminal) 95-NC-96 97-NO-98 Aux terminal 2T1 11.8 4T2 6T3 14.3 45 Main terminal 3.7 32.6 0.167kg 70.5 96.3 57.5 80.6 17.5 GT-63S M6 (Main terminal) 95-NC-96 2T1 97-NO-98 4T2 14 6T3 Aux terminal 18 Main terminal 80.5 5.3 M3.5 (Aux terminal) 55 3.7 31 0.303kg 106.3 64.8 17.5 GT-95S 97.2 B-4-15 95-NC-96 MIDI-cat2008.indd 15 M3.5 (Aux terminal) 97-NO-98 Aux terminal 10/1/08 10:21:50 AM 3.7 96.3 57.5 17.5 GT-63S 80.6 Overload Relays (Lug Type) Overall Dimensions 97-NO-98 95-NC-96 2T1 M6 (Main terminal) 4T2 6T3 14 Aux terminal 18 55 31 Main terminal 80.5 5.3 M3.5 (Aux terminal) Overload relays 3.7 0.303kg 106.3 [mm] 64.8 97.2 17.5 GT-95S 95-NC-96 97-NO-98 M3.5 (Aux terminal) 4T2 6T3 17 22.5 42 Main terminal 6 M8 (Main terminal) Aux terminal 2T1 0.474kg 90.5 70 3.7 [mm] 96.3 57.5 81.1 17.5 GT-63L 95-NC-96 M3.5 (Aux terminal) Aux terminal 2T1 4T2 9.5 6T3 18 Main terminal 2 M6 (Main terminal) 97-NO-98 55 31 0.326kg 80.5 3.7 106.3 64.8 95.4 17.5 GT-95L 95-NC-96 M3.5 (Aux terminal) Aux terminal 4T2 6T3 22.5 12.4 70 2 2T1 Main terminal 97-NO-98 42 Main terminal 90.5 0.491kg B-4-16 MIDI-cat2008.indd 16 9/19/08 8:02:16 PM OVERLOAD RELAY NUMBERING SYSTEM GT 32 S 6A Overload Relay Frame Size 12 32 63 95 Terminal Type S Screw L Lug (for contactors with lug type terminals) Setting Range Frame Size 32 0.1-0.16 63 95 4-6 7-10 0.16-0.25 5-8 9-13 0.25-0.4 6-9 12-18 0.63-1 7-10 16-22 1-1.6 12-18 24-36 1.6-2.5 16-22 28-40 2.5-4 18-25 34-50 4-6 24-36 45-65 5-8 28-40 54-75 6-9 34-50 63-85 7-10 45-65 70-95 9-13 12-18 16-22 18-25 22-32 MIDI-cat2008.indd 17 Ordering Notes: llll GTllll GTllll GTllll GTllll GTllll GTllll GTllll GTllll GTllll GTllll GTllll GTllll GTllll GTllll GTllll GTllll GT 9/19/08 7:57:44 PM