Transcript
Overview Our 4’ 20W LED T8 lamps replace legacy 4’ (T8/T10/T12) fluorescent lamps resulting in superior flicker-free and “dotless” illumination with 20% less power consumed. These LED lamps offer a greener energy solution with no toxic phosphors or hazardous mercury. No starters or ballasts are required and with up to 50,000 hours operating life, there is little to no maintenance required after installation. A patented 180 dg rotating end cap allows exact beam angle adjustment.This product is UL approved for retrofit installations and meets FCC & CE-EMC code requirements.
ILT8LED-1200CW (20W LED T8 Replacement Lamp)
Specifications ILT8LED-1200CW Length
47.17” (1198mm)
Diameter
1.27” (32.30mm)
Socket
G13 (for T8/T10/T12)
Input Voltage Range
100-277VAC 50/60 Hz
Power Consumption
20W
Ingress Protection
IP45
.
Warning
1
2
These products may represent a possible shock or fire hazard if improperly installed or attached in any way. Products should be installed in accordance with these instructions, any applicable electrical codes and/or the current National Electric Code (NEC).
Risk of fire or electric shock. Retrofit installation requires knowledge of fluorescent lighting fixture wiring. If not qualified, do not attempt installation. Contact a qualified electrician.
Risk of fire or electric shock. These T8 LED lamps are not compatible with luminaires employing shunted bi-pin lamp holders
Note: Imtra T8 lamps are designed to be used with non-shunted Sockets. Shunted lamp holders are common in fluorescent fixtures with Instant-Start ballasts. See photo below. Instant-Start ballasts can be identified by the words “Instant Start” or “I.S.” or the designation “IS” within the lamp marking on the ballast.
Installation & Wiring 1. Disconnect power at source. 2. Remove diffuser lens (if applicable) and fluorescent lamp(s). 3. Open\Remove Wiring Compartment Cover. 4. Disconnect all ballast wires from all lamp sockets and AC power supply wiring. The ballast will be completely bypassed and may be removed if desired.
Fig. 1
5. Confirm type of “tombstone” sockets (see Fig. 1) and remove only the shunted sockets that will be connected to AC voltage.
VS. Non-Shunted
Internally Shunted
6. Connect black (L) and white (N) AC power supply wires to the two terminals on the lamp socket. If the fixture has more than one lamp, connect one socket per lamp in parallel. Leave socket(s) at the opposite end of each lamp disconnected from power. See Fig. 2 below:
If you do not have the correct type of sockets, these may be sourced directly through Imtra or any electrical supply outlet. If you are unsure which socket you need, please contact Imtra. Note: For fluorescent fixtures with starters, the starters must be disconnected from the circuit. Please do not remove the starter(s) from the fixture as this may create an opening through which moisture and water may enter. CAUTION:
Fig. 2
1. Make sure that the electrical power to the fixture is disconnected prior to any installation or retrofit. 2. Read all instructions regarding ballast bypass and non-shunted sockets before beginning retrofit. 3. Caution: Risk of Electric Shock. Do not use where directly exposed to water!
7. Insert the wired sockets back in to their mounting slots, pressing in until fully seated.
4. Not for use with dimmers.
8. Close compartment cover (plate). Install lamps making sure the end labeled “Single-End Input” is inserted into the socket connected to AC voltage. Re-attach the lens diffuser cover plate.
5. Do not use in conjunction with any type of ballast or driver. LED T8 Tubes are designed for 100-277V AC, 50/60Hz input only.
9. Restore power to circuit and switch on fixture to test.
3
4
Scenarios
Limited Warranty
1. Retrofit Installation with One Lamp/Magnetic Ballast/Starter
Imtra warrants our T8 LED Lamps for a period of 3 years from the date of purchase. If a lamp should cease to function normally within this time period, contact Imtra for instructions regarding return of the product. This warranty does not apply to damage resulting from actions of the user such as misuse, improper wiring/installation, operation outside of specification, improper maintenance or repair, unauthorized modification, lightning strike or damage from a power surge. Imtra specifically disclaims any implied warranties, merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Imtra's total liability is limited to repair or replacement of the product.
Starter
X
X N L
X Ballast
If it should become necessary to return a lamp for any reason or beyond the warranty period, please refer to Imtra's standard Return Policy as detailed on Imtra's website (www.imtra.com) or call Imtra customer service at (508) 995-7000.
N L
2. Retrofit Installation with One Lamp/Electronic Ballast
No returns are accepted without a Return Authorization (RA) number. N L
X X
X
X Ballast
N L
3. Retrofit Installation wtih Dual Lamp Connection
N L
X
X
X
X
Ballast
N L
5
6
30 Samuel Barnet Boulevard, New Bedford, MA 02745 (508) 995-7000 www.imtra.com
7
8