Preview only show first 10 pages with watermark. For full document please download

Ovp-100mb-hipoe-box

   EMBED


Share

Transcript

Overvoltage protections of ethernet devices with PoE up to 90W OVP-100MB-HIPOE-BOX BOX BOX + DIN35-LOCK* ▪ Industrial design ▪ Two-stage protection up to 10kA ▪ Compatible with PoE acc. to EEE 802.3af / at ▪ Transmitted power up to 90W ▪ PE terminal galvanically isolated ▪ Working temperature from – 40°C to +70°C BOX + PATCH-BOX-8W52 ORDERING NAME CODE NOTES OVP-100MB-HIPOE-BOX* 4-449-104 Ethernet + PoE A and B DIN35-LOCK 4-500-019 DIN35 holder PATCH-BOX-8W52 500-111 19" patch Accessories: * holder DIN35-LOCK for mounting to DIN35 is included OVP-100MB-HIPOE-BOX - protections for IP devices with PoE / PoE+ / PoE++ 10/100Mbps ethernet 10/100Mbps ethernet OVP-100MB-HIPOE-BOX PoE/PoE+/High PoE PoE/PoE+/High PoE Protected side max.10m Description and technical parameters OVP-100MB-HIPOE-BOX are high performance overvoltage protections designed for protection of LAN devices against surge peaks with amplitude up to 10kA. Protections are compatible with PoE according to standards IEEE 802.3af or PoE+ IEEE802.3at up to the maximum output power 90W and voltage 58VDC. Grounding PE terminal is galvanically isolated from signal terminals. Overvoltage protection Parameter Value Protected pairs 4 Unit Note Max. operating voltage Nominal operating current 8.4 / 58 V data / PoE 0,7 A each pair Max. operating current 1 A each pair C2 nominal discharge current In(8/20) 1 kA C2 voltage protection level Up 45.2 / 90.4 V data/PoE C2 voltage protection level Up 620 V pairs to PE C2 max. discharge current (8/20) 10 kA 1-8/PE Transmitted power Max. 90 W Transmission speed Max. 100 Mbps Operational range –40...+80 °C non condensing Storage range –40...+80 °C non condensing Mechanical Dimensions - w / h / l Page 3. Parameters Connection RJ45 / RJ45 input / output PE connection Stranded wire 1.5 mm2 Transmission Environment Tested in accordance with IEC61643:21-2000 The producer retains the right to change any technical parameters without previous announcement. www.metel.eu 1/3 www.metel.eu Installation manual REV:201502 OVP-100MB-HIPOE-BOX Overvoltage protections of ethernet devices with PoE up to 90W Installation and Setting 1. Mount the protection to surface. 2. Ground the yellow-green wire to the closest earth bar with maximum earth resistance 10Ω. Earthing should be done in accordance to the national standards. 3. Connect UTP Cat5e cables according to the pictures below. Connect the unprotected side towards the expected source of overvoltage. OVP-100MB-HIPOE-BOX Grounding max. 10 Ω PROTECTED SIDE Unprotected side UTPcat5e Ethernet + PoE SURGE ARRESTER – ETHERNET OVP-100MB-HIPOE-BOX Protected side max.10m UTPcat5e Ethernet + PoE CODE:4-449-104 PATCH-BOX-8W52 It is possible to screw up to 8 overvoltage protections OVP-100MB...to 19" patch panel PATCH-BOX-8W52. For proper functionality follow these rules: 1. Cut the yellow-green earthing wires from the overvoltage protections that are to be screwed to the patch panel. 2. Reliable earthing of the protections is ensured by: · screwing of overvoltage protections to the patch panel using screws M3x5 from accessories, · connecting of patch panel with earthing point with max. earth resistance 10Ω. The connection must be realized using a wire of min. cross-section 2.5 mm2. Other recommendations: · protected wires should not cross the unprotected, · min. recommended distance between protected and unprotected wiring is 10 cm, · do not use lightning conductor for earthing. PROTECTED SIDE PROTECTED SIDE PROTECTED SIDE Protected side Grounding max. 10 Ω www.metel.eu PROTECTED SIDE Holes for screwing overvoltage protection 2/3 Grounding max. 10 Ω www.metel.eu Installation manual REV:201502 OVP-100MB-HIPOE-BOX Overvoltage protections of ethernet devices with PoE up to 90W Dimensions of OVP-100MB-HIPOE-BOX Dimension PATCH-BOX-8W52 www.metel.eu 3/3 www.metel.eu