Preview only show first 10 pages with watermark. For full document please download

Owners Manual For Ohaus

   EMBED


Share

Transcript

Defender™ Series Base Instruction Manual Compliance This product conforms to the EMC directive 2004/108/EC and the Low Voltage Directive 2006/95/EC. The complete declaration of Conformity is available from Ohaus Corporation Disposal In conformance with the European Directive 2002/96 EC on Waste Electrical and Electronic Equipment (WEEE) this device may not be disposed of in domestic waste. This also applies to countries outside the EU, per their specific requirements. Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and electronic equipment. If you have any questions, please contact the responsible authority or the distributor from which you purchased this device. Should this device be passed on to other parties (for private or professional use), the content of this regulation must also be related. Thank you for your contribution to environmental protection. ISO 9001 Registration In 1994, Ohaus Corporation, USA, was awarded a certificate of registration to ISO 9001 by Bureau Veritus Quality International (BVQI), confirming that the Ohaus quality management system is compliant with the ISO 9001 standard’s requirements. On May 15, 2003, Ohaus Corporation, USA, was re-registered to the ISO 9001:2000 standard. EN-1 Defender Series Base INTRODUCTION This manual covers installation, and maintenance instructions for the Ohaus Defender TM Series Base. Please read this manual completely before installation and operation. SAFETY PRECAUTIONS For safe and dependable operation of this product, please comply with the following precautions: • Operate the base only under ambient conditions specified in these instructions • Ensure that the load cell cable does not pose an obstruction or tripping hazard • Do not operate the base in hazardous environments or unstable locations • Do not drop loads on the base • Do not lift the base by the top frame; always lift from the bottom frame when moving the base • Service should only be performed by authorized personnel INSTALLATION Unpacking Unpack and inspect the product to make sure that all components have been included. The package includes the following: • Defender TM Series Base • Weighing Pan • Instruction Manual When purchased as a complete Defender Series Scale, the package will also include: • Indicator • Column Assembly (optional) ASSEMBLY Weighing Pan Place the weighing pan securely over the rubber load pads on the top frame of the base. Wiring Connections DxxxHx, DxxxQx, and DxxxRx Bases When connecting the DxxxHx, DxxxQx, or DxxxRx base to an Ohaus indicator equipped with the matching circular connector, push the base connector onto the indicator connector and turn the locking ring clockwise to lock it in place. When connecting the DxxxHx, DxxxQx, or DxxxRx base to an indicator that does not have the matching connector, install the optional load cell cable adapter (P/N 80500736 sold separately) to the indicator using the wiring codes in Table 1. Then attach the load cell cable to the cable adapter. Note: As an alternate wiring method, cut off the connector, strip the wires and attach them to the indicator using the wiring codes in Table 1. DxxxWx Bases Install the load cell cable to an indicator using the wiring codes in Table 1. Note: When purchased as a Defender Series Scale, the DxxxWx base is already pre-wired to the indicator. TABLE 1. LOAD CELL CONNECTION FUNCTION WIRE COLOR + Excitation Green - Excitation Black + Signal Red - Signal White + Sense Blue - Sense Brown Shield Yellow EN-2 Defender Series Base Selecting the Location To ensure accuracy, proper performance and safety, locate and operate the base on a stable, level surface. Avoid locations with rapid temperature changes or excessive dust, air currents, vibrations, electromagnetic fields or heat. Level the base by adjusting the four leveling feet until the bubble in the level indicator is centered. A wrench may be needed to loosen the locking nut above each leveling foot. When the base is level, retighten the locking nuts up against the base to lock each foot into place. Note: Ensure that the base is level each time its location is changed. CORRECT INCORRECT MAINTENANCE Cleaning The base components should be kept clean and free of excessive material build up. • A damp cloth with water and a mild detergent may be used to wipe clean the external surfaces – do not use acids, alkalis, strong solvents or abrasive materials. To maintain surface integrity, do not allow food particles or liquids to remain on the surface of the painted or stainless steel base frame. • Remove the pan and use fresh water to clean the base frame surface of any food particles or liquids. Dry the base with a clean cloth or allow to air dry before replacing the pan. Repeat daily for best care. Troubleshooting Aside from installing components and leveling adjustments, the Defender Series Base does not require any other adjustments as shipped from the factory. Operational difficulties that may be encountered can often be traced to simple causes such as: • Loose or incorrect wiring connections • Obstructions to the base frame • Unstable environments • Incorrect calibration or setup of the indicator If the troubleshooting section does not resolve or describe your problem, contact your authorized Ohaus service agent. For service assistance or technical support in the United States call toll-free 1-800-526-0659 between 8:00 AM and 5:00 PM EST. An Ohaus product service specialist will be available to provide assistance. Outside the USA, please visit our web site, www.ohaus.com to locate the Ohaus office nearest you. EN-3 Defender Series Base TECHNICAL DATA Technical Specifications The technical data is valid under the following ambient conditions: Ambient temperature: -10ºC to +40 ºC Relative humidity: 10% to 90% relative humidity, non-condensing Height above sea level: Up to 4,000m Operability is assured at ambient temperature -10ºC to +40 ºC Note: not all models may be available in your area. Check with your local Ohaus representative. TABLE 2.1 SPECIFICATIONS MODEL D15HR Capacity 15 kg / 30 lb Approved Resolution D60HR 30 kg / 60 lb 60 kg / 150 lb OIML: 3000e, NTEP: 3000d Safe Overload Capacity 150% of capacity Pan Dimensions 305 x 355 mm / 12 x 14 in Base Construction Stainless Steel platform with painted steel frame and rubber leveling feet Repeatability (std. deviation) 1d Linearity Load Cell Capacity D30HR ±1d 30 kg 50 kg 100 kg Load Cell Cable 2 m L x 6-wire Load Cell Type 350 Ohm, aluminum, single point Load Cell Excitation 5-15V DC/AC Load Cell Rated Output 2mV/V Load Cell Protection IP67 Net Weight 9 kg / 19.8 lb Shipping Weight 10.9 kg / 24 lb TABLE 2.2. SPECIFICATIONS MODEL D60HL D100HL D150HX Capacity 60 kg / 100 lb 100 kg / 250 lb 150 kg / 300 lb Approved Resolution OIML: 3000e, NTEP: 3000d OIML: 3000e, NTEP: 2500d Safe Overload Capacity Pan Dimensions 400 x 500 mm / 15.7 x 19.7 in 420 x 550 mm / 16.5 x 21.6 in Stainless Steel platform with painted steel frame and rubber leveling feet Repeatability (std. deviation) 1d Linearity ±1d 100 kg 150 kg 300 kg Load Cell Cable 2 m L x 6-wire Load Cell Type 350 Ohm, aluminum, single point Load Cell Excitation 2mV/V Load Cell Protection Shipping Weight 500 kg 5-15V DC/AC Load Cell Rated Output Net Weight 300 kg / 600 lb OIML: 3000e, NTEP: 3000d 150% of capacity Base Construction Load Cell Capacity D300HX IP67 19.1 kg / 42.1 lb 24.5 kg 22 kg / 48.5 lb 27.1 kg / 59.7 lb EN-4 Defender Series Base TABLE 2.3 SPECIFICATIONS MODEL D10QR D15QR D25QR D30QR D50QL Capacity 10 kg / 25 lb Approved Resolution NTEP: 5000d 15 kg / 30 lb 25 kg / 50 lb 30 kg / 60 lb 50 kg / 100 lb OIML: 3000e NTEP: 5000d OIML: 3000e NTEP: 5000d Safe Overload Capacity 150% of capacity Pan Dimensions 305 x 305 mm / 12 x 12 in Base Construction 457 x 457 mm / 18 x 18 in Stainless Steel platform with painted steel frame and rubber leveling feet Repeatability (std. deviation) 1d Linearity Load Cell Capacity ±1d 30 kg 30 kg 50 kg 50 kg Load Cell Cable 2.5 m L x 6-wire Load Cell Type 350 Ohm, aluminum, single point Load Cell Excitation 100 kg 5-15V DC/AC Load Cell Rated Output 2mV/V Load Cell Protection IP67 Net Weight 12.2 kg / 26.9 lb 27.2 kg / 60 lb Shipping Weight 14.2 kg / 31.3 lb 29 kg / 64 lb TABLE 2.4 SPECIFICATIONS MODEL D60QL D100QL D150QL D250QX D300QX Capacity 60 kg / 150 lb 100 kg / 250 lb 150 kg / 300 lb 250 kg / 500 lb 300 kg / 600 lb OIML: 3000e NTEP: 5000d OIML: 3000e NTEP: 5000d OIML: 3000e Approved Resolution Safe Overload Capacity 150% of capacity Pan Dimensions 457 x 457 mm / 18 x 18 in Base Construction Stainless Steel platform with painted steel frame and rubber leveling feet Repeatability (std. deviation) 1d Linearity Load Cell Capacity 610 x 610 mm / 24 x 24 in ±1d 100 kg 150 kg 200 kg Load Cell Cable 2.5 m L x 6-wire Load Cell Type 350 Ohm, aluminum, single point Load Cell Excitation 2mV/V Load Cell Protection Shipping Weight 500 kg 5-15V DC/AC Load Cell Rated Output Net Weight 500 kg IP67 27.2 kg / 60 lb 35 kg / 77 lb 29 kg / 64 lb 41 kg / 90 lb EN-5 Defender Series Base TABLE 2.5 SPECIFICATIONS MODEL D10WR D15WR D25WR D30WR D50WL Capacity 10 kg / 25 lb 15 kg / 30 lb 25 kg / 50 lb 30 kg / 60 lb 50 kg / 100 lb Approved Resolution NTEP: 5000d OIML: 3000e NTEP: 5000d OIML: 3000e NTEP: 5000d Safe Overload Capacity 150% of capacity Pan Dimensions 305 x 305 mm / 12 x 12 in Base Construction 457 x 457 mm / 18 x 18 in Stainless Steel platform with stainless steel frame and rubber leveling feet Repeatability (std. deviation) 1d Linearity Load Cell Capacity ±1d 30 kg 30 kg 50 kg 50 kg Load Cell Cable 2.5 m L x 6-wire Load Cell Type 350 Ohm, stainless steel, single point Load Cell Excitation 100 kg 5-15V DC/AC Load Cell Rated Output 2mV/V Load Cell Protection IP67 Net Weight 12.2 kg / 26.9 lb 27.2 kg / 60 lb Shipping Weight 14.2 kg / 31.3 lb 29 kg / 64 lb TABLE 2.6 SPECIFICATIONS MODEL D60WL D100WL D150WL D250WX D300WX Capacity 60 kg / 150 lb 100 kg / 250 lb 150 kg / 300 lb 250 kg / 500 lb 300 kg / 600 lb OIML: 3000e NTEP: 5000d OIML: 3000e NTEP: 5000d OIML: 3000e Approved Resolution Safe Overload Capacity 150% of capacity Pan Dimensions 457 x 457 mm / 18 x 18 in Base Construction Stainless Steel platform with stainless steel frame and rubber leveling feet Repeatability (std. deviation) 1d Linearity Load Cell Capacity 610 x 610 mm / 24 x 24 in ±1d 100 kg 200 kg 200 kg Load Cell Cable 2.5 m L x 6-wire Load Cell Type 350 Ohm, stainless steel, single point Load Cell Excitation 2mV/V Load Cell Protection Shipping Weight 500 kg 5-15V DC/AC Load Cell Rated Output Net Weight 500 kg IP67 27.2 kg / 60 lb 35 kg / 77 lb 29 kg / 64 lb 41 kg / 90 lb EN-6 Defender Series Base TABLE 2.7 SPECIFICATIONS MODEL Capacity Approved Resolution D5RS D6RS D10RS D15RS D25RR D30RR 5 kg / 10 lb 6 kg / 15 lb 10 kg / 25 lb 15 kg / 30 lb 25 kg / 50 lb 30 kg / 60 lb NTEP: 5000d OIML: 3000e NTEP: 5000d OIML: 3000e NTEP: 5000d OIML: 3000e Safe Overload Capacity 150% of capacity Pan Dimensions 240 x 300 mm / 9.4 x 11.8 in Base Construction 300 x 400 mm / 11.8 x 15.7 in Stainless Steel platform with painted steel frame and rubber leveling feet Repeatability (std. deviation) 1d Linearity ±1d Load Cell Capacity 11 kg 22 kg Load Cell Cable 50 kg 1 m L x 6-wire Load Cell Type 2 m L x 6-wire 350 Ohm, aluminum, single point Load Cell Excitation 5-15V DC/AC Load Cell Rated Output 2mV/V Load Cell Protection IP65 Net Weight 5.9 kg / 13 lb 9.9 kg / 22 lb Shipping Weight 8.1 kg / 18 lb 12 kg / 26.5 lb TABLE 2.8 SPECIFICATIONS MODEL D50RR D50RL D50RX D60RR D60RL D60RX Capacity 50 kg / 100 lb 50 kg / 100 lb 50 kg / 100 lb 60 kg / 150 lb 60 kg / 150 lb 60 kg / 150 lb Approved Resolution NTEP: 5000d NTEP: 5000d NTEP: 5000d OIML: 3000e OIML: 3000e OIML: 3000e 400 x 500 mm 15.7 x 19.7 in 500 x 650 mm 19.7 x 25.6 in Safe Overload Capacity Pan Dimensions 150% of capacity 300 x 400 mm 400 x 500 mm 11.8 x 15.7 in 15.7 x 19.7 in 500 x 650 mm 19.7 x 25.6 in 300 x 400 mm 11.8 x 15.7 in Base Construction Stainless Steel platform with painted steel frame and rubber leveling feet Repeatability (std. deviation) 1d Linearity ±1d Load Cell Capacity Load Cell Cable 100 kg 2 m L x 6-wire 2.5 m L x 6-wire Load Cell Type 2 m L x 6-wire 2.5 m L x 6-wire 350 Ohm, aluminum, single point Load Cell Excitation 5-15V DC/AC Load Cell Rated Output 2mV/V Load Cell Protection IP65 Net Weight 9.9 kg / 22 lb 19.4kg / 43lb 22.3 kg / 49 lb 9.9 kg / 22 lb 19.4 kg / 43 lb 22.3 kg / 49 lb Shipping Weight 12 kg / 26.5 lb 22.3kg / 49lb 27.8 kg / 61 lb 12 kg / 26.5 lb 22.3 kg / 49 lb 27.8 kg / 61 lb EN-7 Defender Series Base TABLE 2.9 SPECIFICATIONS MODEL D100RL D100RX D100RV D150RL D150RX Capacity 100 kg / 250 lb 100 kg / 250 lb 100 kg / 250 lb 150 kg / 300 lb 150 kg / 300 lb NTEP: 5000d NTEP: 5000d NTEP: 5000d OIML: 3000e OIML: 3000e 400 x 500 mm 15.7 x 19.7 in 500 x 650 mm 19.7 x 25.6 in 600 x 800 mm 23.6 x 31.5 in 400 x 500 mm 15.7 x 19.7 in 500 x 650 mm 19.7 x 25.6 in Approved Resolution Safe Overload Capacity Pan Dimensions 150% of capacity Base Construction Stainless Steel platform with painted steel frame and rubber leveling feet Repeatability (std. deviation) 1d Linearity ±1d Load Cell Capacity 250 kg Load Cell Cable 2.5 m L x 6-wire Load Cell Type 350 Ohm, aluminum, single point Load Cell Excitation 5-15V DC/AC Load Cell Rated Output 2mV/V Load Cell Protection IP65 Net Weight 19.4 kg / 43 lb 22.3 kg / 49 lb 36.8 kg / 81 lb 19.4 kg / 43 lb 22.3 kg / 49 lb Shipping Weight 22.3 kg / 49 lb 27.8 kg / 61 lb 63.2 kg / 139 lb 22.3 kg / 49 lb 27.8 kg / 61 lb TABLE 2.10 SPECIFICATIONS MODEL D150RV D250RX D250RV D300RX D300RV Capacity 150 kg / 300 lb 250 kg / 500 lb 250 kg / 500 lb 300 kg / 600 lb 300 kg / 600 lb OIML: 3000e NTEP: 5000d NTEP: 5000d OIML: 3000e OIML: 3000e 600 x 800 mm 23.6 x 31.5 in 500 x 650 mm 19.7 x 25.6 in 600 x 800 mm 23.6 x 31.5 in 500 x 650 mm 19.7 x 25.6 in 600 x 800 mm 23.6 x 31.5 in Approved Resolution Safe Overload Capacity Pan Dimensions 150% of capacity Base Construction Stainless Steel platform with painted steel frame and rubber leveling feet Repeatability (std. deviation) 1d Linearity Load Cell Capacity ±1d 250 kg 500 kg Load Cell Cable 2.5 m L x 6-wire Load Cell Type 350 Ohm, aluminum, single point Load Cell Excitation 5-15V DC/AC Load Cell Rated Output 2mV/V Load Cell Protection IP65 Net Weight 36.8 kg / 81 lb 22.3 kg / 49 lb 36.8 kg / 81 lb 22.3 kg / 49 lb 36.8 kg / 81 lb Shipping Weight 63.2 kg / 139 lb 27.8 kg / 61 lb 63.2 kg / 139 lb 27.8 kg / 61 lb 63.2 kg / 139 lb EN-8 Defender Series Base Drawings Figure 1. Defender Base Dimension Drawing. A TABLE 3. DIMENSIONS B C Height of Pan to Pan Width Surface of Table* 305 mm 95 mm 50 mm E Depth Including Level Indicator 385 mm 105 mm 60 mm 530 mm 420 mm 125 mm 70 mm 580 mm 305 mm 305 mm 95 mm 52 mm 335 mm DxxxQL, DxxxWL 457 mm 457 mm 115 mm 70 mm 487 mm DxxxQX, DxxxWX 610 mm 610 mm 137 mm 90 mm 640 mm DxxxRS 300 mm 240 mm 80 mm 44 mm 330 mm DxxxRR 400 mm 300 mm 86 mm 50 mm 430 mm DxxRL 500 mm 400 mm 86 mm 48 mm 530 mm DxxxRX 650 mm 500 mm 110 mm 73 mm 695 mm DxxxRV 800 mm 600 mm 120 mm *For leveling purposes, the feet may be extended up to an additional 15 mm. 83 mm 840 mm Base Pan Depth DxxxHR 355 mm DxxxHL 500 mm 400 mm DxxxHX 550 mm DxxQR, DxxxWR D Height of Pan EN-9 Defender Series Base Accessories TABLE 4. ACCESSORIES Description Part Number Base Mount Kit, painted steel 80500722 Column Kit, 35 cm painted steel 80500723 Column Kit, 68 cm painted steel 80500724 Column Kit, 35 cm stainless steel 80500725 Column Kit, 68 cm stainless steel 80500726 Load Cell Cable Adapter Kit 80500736 LIMITED WARRANTY Ohaus products are warranted against defects in materials and workmanship from the date of delivery through the duration of the warranty period. During the warranty period Ohaus will repair, or, at its option, replace any component(s) that proves to be defective at no charge, provided that the product is returned, freight prepaid, to Ohaus. This warranty does not apply if the product has been damaged by accident or misuse, exposed to radioactive or corrosive materials, has foreign material penetrating to the inside of the product, or as a result of service or modification by other than Ohaus. In lieu of a properly returned warranty registration card, the warranty period shall begin on the date of shipment to the authorized dealer. No other express or implied warranty is given by Ohaus Corporation. Ohaus Corporation shall not be liable for any consequential damages. As warranty legislation differs from state to state and country to country, please contact Ohaus or your local Ohaus dealer for further details. Ohaus Corporation 19A Chapin Road P.O. Box 2033 Pine Brook, NJ 07058-2033, USA Tel: (973) 377-9000 Fax: (973) 944-7177 With offices worldwide. www.ohaus.com *80251421* P/N 80251421 B © Ohaus Corporation 2008, all rights reserved. Printed in China