Transcript
Defender™ Series Base Instruction Manual
Compliance This product conforms to the EMC directive 2004/108/EC and the Low Voltage Directive 2006/95/EC. The complete declaration of Conformity is available from Ohaus Corporation
Disposal In conformance with the European Directive 2002/96 EC on Waste Electrical and Electronic Equipment (WEEE) this device may not be disposed of in domestic waste. This also applies to countries outside the EU, per their specific requirements. Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and electronic equipment. If you have any questions, please contact the responsible authority or the distributor from which you purchased this device. Should this device be passed on to other parties (for private or professional use), the content of this regulation must also be related. Thank you for your contribution to environmental protection.
ISO 9001 Registration In 1994, Ohaus Corporation, USA, was awarded a certificate of registration to ISO 9001 by Bureau Veritus Quality International (BVQI), confirming that the Ohaus quality management system is compliant with the ISO 9001 standard’s requirements. On May 15, 2003, Ohaus Corporation, USA, was re-registered to the ISO 9001:2000 standard.
EN-1
Defender Series Base
INTRODUCTION This manual covers installation, and maintenance instructions for the Ohaus Defender TM Series Base. Please read this manual completely before installation and operation.
SAFETY PRECAUTIONS For safe and dependable operation of this product, please comply with the following precautions: • Operate the base only under ambient conditions specified in these instructions • Ensure that the load cell cable does not pose an obstruction or tripping hazard • Do not operate the base in hazardous environments or unstable locations • Do not drop loads on the base • Do not lift the base by the top frame; always lift from the bottom frame when moving the base • Service should only be performed by authorized personnel
INSTALLATION Unpacking Unpack and inspect the product to make sure that all components have been included. The package includes the following: • Defender TM Series Base • Weighing Pan • Instruction Manual When purchased as a complete Defender Series Scale, the package will also include: • Indicator • Column Assembly (optional)
ASSEMBLY Weighing Pan Place the weighing pan securely over the rubber load pads on the top frame of the base.
Wiring Connections DxxxHx, DxxxQx, and DxxxRx Bases When connecting the DxxxHx, DxxxQx, or DxxxRx base to an Ohaus indicator equipped with the matching circular connector, push the base connector onto the indicator connector and turn the locking ring clockwise to lock it in place. When connecting the DxxxHx, DxxxQx, or DxxxRx base to an indicator that does not have the matching connector, install the optional load cell cable adapter (P/N 80500736 sold separately) to the indicator using the wiring codes in Table 1. Then attach the load cell cable to the cable adapter. Note: As an alternate wiring method, cut off the connector, strip the wires and attach them to the indicator using the wiring codes in Table 1.
DxxxWx Bases Install the load cell cable to an indicator using the wiring codes in Table 1. Note: When purchased as a Defender Series Scale, the DxxxWx base is already pre-wired to the indicator. TABLE 1. LOAD CELL CONNECTION FUNCTION WIRE COLOR + Excitation Green - Excitation Black + Signal Red - Signal White + Sense Blue - Sense Brown Shield Yellow
EN-2
Defender Series Base
Selecting the Location To ensure accuracy, proper performance and safety, locate and operate the base on a stable, level surface. Avoid locations with rapid temperature changes or excessive dust, air currents, vibrations, electromagnetic fields or heat. Level the base by adjusting the four leveling feet until the bubble in the level indicator is centered. A wrench may be needed to loosen the locking nut above each leveling foot. When the base is level, retighten the locking nuts up against the base to lock each foot into place. Note: Ensure that the base is level each time its location is changed. CORRECT
INCORRECT
MAINTENANCE Cleaning The base components should be kept clean and free of excessive material build up. • A damp cloth with water and a mild detergent may be used to wipe clean the external surfaces – do not use acids, alkalis, strong solvents or abrasive materials. To maintain surface integrity, do not allow food particles or liquids to remain on the surface of the painted or stainless steel base frame. • Remove the pan and use fresh water to clean the base frame surface of any food particles or liquids. Dry the base with a clean cloth or allow to air dry before replacing the pan. Repeat daily for best care.
Troubleshooting Aside from installing components and leveling adjustments, the Defender Series Base does not require any other adjustments as shipped from the factory. Operational difficulties that may be encountered can often be traced to simple causes such as: • Loose or incorrect wiring connections • Obstructions to the base frame • Unstable environments • Incorrect calibration or setup of the indicator If the troubleshooting section does not resolve or describe your problem, contact your authorized Ohaus service agent. For service assistance or technical support in the United States call toll-free 1-800-526-0659 between 8:00 AM and 5:00 PM EST. An Ohaus product service specialist will be available to provide assistance. Outside the USA, please visit our web site, www.ohaus.com to locate the Ohaus office nearest you.
EN-3
Defender Series Base
TECHNICAL DATA Technical Specifications The technical data is valid under the following ambient conditions: Ambient temperature: -10ºC to +40 ºC Relative humidity: 10% to 90% relative humidity, non-condensing Height above sea level: Up to 4,000m Operability is assured at ambient temperature -10ºC to +40 ºC Note: not all models may be available in your area. Check with your local Ohaus representative. TABLE 2.1 SPECIFICATIONS MODEL
D15HR
Capacity
15 kg / 30 lb
Approved Resolution
D60HR
30 kg / 60 lb
60 kg / 150 lb
OIML: 3000e, NTEP: 3000d
Safe Overload Capacity
150% of capacity
Pan Dimensions
305 x 355 mm / 12 x 14 in
Base Construction
Stainless Steel platform with painted steel frame and rubber leveling feet
Repeatability (std. deviation)
1d
Linearity Load Cell Capacity
D30HR
±1d 30 kg
50 kg
100 kg
Load Cell Cable
2 m L x 6-wire
Load Cell Type
350 Ohm, aluminum, single point
Load Cell Excitation
5-15V DC/AC
Load Cell Rated Output
2mV/V
Load Cell Protection
IP67
Net Weight
9 kg / 19.8 lb
Shipping Weight
10.9 kg / 24 lb
TABLE 2.2. SPECIFICATIONS MODEL
D60HL
D100HL
D150HX
Capacity
60 kg / 100 lb
100 kg / 250 lb
150 kg / 300 lb
Approved Resolution
OIML: 3000e, NTEP: 3000d
OIML: 3000e, NTEP: 2500d
Safe Overload Capacity Pan Dimensions
400 x 500 mm / 15.7 x 19.7 in
420 x 550 mm / 16.5 x 21.6 in
Stainless Steel platform with painted steel frame and rubber leveling feet
Repeatability (std. deviation)
1d
Linearity
±1d 100 kg
150 kg
300 kg
Load Cell Cable
2 m L x 6-wire
Load Cell Type
350 Ohm, aluminum, single point
Load Cell Excitation
2mV/V
Load Cell Protection Shipping Weight
500 kg
5-15V DC/AC
Load Cell Rated Output Net Weight
300 kg / 600 lb
OIML: 3000e, NTEP: 3000d
150% of capacity
Base Construction
Load Cell Capacity
D300HX
IP67 19.1 kg / 42.1 lb
24.5 kg
22 kg / 48.5 lb
27.1 kg / 59.7 lb
EN-4
Defender Series Base
TABLE 2.3 SPECIFICATIONS MODEL
D10QR
D15QR
D25QR
D30QR
D50QL
Capacity
10 kg / 25 lb
Approved Resolution
NTEP: 5000d
15 kg / 30 lb
25 kg / 50 lb
30 kg / 60 lb
50 kg / 100 lb
OIML: 3000e
NTEP: 5000d
OIML: 3000e
NTEP: 5000d
Safe Overload Capacity
150% of capacity
Pan Dimensions
305 x 305 mm / 12 x 12 in
Base Construction
457 x 457 mm / 18 x 18 in
Stainless Steel platform with painted steel frame and rubber leveling feet
Repeatability (std. deviation)
1d
Linearity Load Cell Capacity
±1d 30 kg
30 kg
50 kg
50 kg
Load Cell Cable
2.5 m L x 6-wire
Load Cell Type
350 Ohm, aluminum, single point
Load Cell Excitation
100 kg
5-15V DC/AC
Load Cell Rated Output
2mV/V
Load Cell Protection
IP67
Net Weight
12.2 kg / 26.9 lb
27.2 kg / 60 lb
Shipping Weight
14.2 kg / 31.3 lb
29 kg / 64 lb
TABLE 2.4 SPECIFICATIONS MODEL
D60QL
D100QL
D150QL
D250QX
D300QX
Capacity
60 kg / 150 lb
100 kg / 250 lb
150 kg / 300 lb
250 kg / 500 lb
300 kg / 600 lb
OIML: 3000e
NTEP: 5000d
OIML: 3000e
NTEP: 5000d
OIML: 3000e
Approved Resolution Safe Overload Capacity
150% of capacity
Pan Dimensions
457 x 457 mm / 18 x 18 in
Base Construction
Stainless Steel platform with painted steel frame and rubber leveling feet
Repeatability (std. deviation)
1d
Linearity Load Cell Capacity
610 x 610 mm / 24 x 24 in
±1d 100 kg
150 kg
200 kg
Load Cell Cable
2.5 m L x 6-wire
Load Cell Type
350 Ohm, aluminum, single point
Load Cell Excitation
2mV/V
Load Cell Protection Shipping Weight
500 kg
5-15V DC/AC
Load Cell Rated Output Net Weight
500 kg
IP67 27.2 kg / 60 lb
35 kg / 77 lb
29 kg / 64 lb
41 kg / 90 lb
EN-5
Defender Series Base
TABLE 2.5 SPECIFICATIONS MODEL
D10WR
D15WR
D25WR
D30WR
D50WL
Capacity
10 kg / 25 lb
15 kg / 30 lb
25 kg / 50 lb
30 kg / 60 lb
50 kg / 100 lb
Approved Resolution
NTEP: 5000d
OIML: 3000e
NTEP: 5000d
OIML: 3000e
NTEP: 5000d
Safe Overload Capacity
150% of capacity
Pan Dimensions
305 x 305 mm / 12 x 12 in
Base Construction
457 x 457 mm / 18 x 18 in
Stainless Steel platform with stainless steel frame and rubber leveling feet
Repeatability (std. deviation)
1d
Linearity Load Cell Capacity
±1d 30 kg
30 kg
50 kg
50 kg
Load Cell Cable
2.5 m L x 6-wire
Load Cell Type
350 Ohm, stainless steel, single point
Load Cell Excitation
100 kg
5-15V DC/AC
Load Cell Rated Output
2mV/V
Load Cell Protection
IP67
Net Weight
12.2 kg / 26.9 lb
27.2 kg / 60 lb
Shipping Weight
14.2 kg / 31.3 lb
29 kg / 64 lb
TABLE 2.6 SPECIFICATIONS MODEL
D60WL
D100WL
D150WL
D250WX
D300WX
Capacity
60 kg / 150 lb
100 kg / 250 lb
150 kg / 300 lb
250 kg / 500 lb
300 kg / 600 lb
OIML: 3000e
NTEP: 5000d
OIML: 3000e
NTEP: 5000d
OIML: 3000e
Approved Resolution Safe Overload Capacity
150% of capacity
Pan Dimensions
457 x 457 mm / 18 x 18 in
Base Construction
Stainless Steel platform with stainless steel frame and rubber leveling feet
Repeatability (std. deviation)
1d
Linearity Load Cell Capacity
610 x 610 mm / 24 x 24 in
±1d 100 kg
200 kg
200 kg
Load Cell Cable
2.5 m L x 6-wire
Load Cell Type
350 Ohm, stainless steel, single point
Load Cell Excitation
2mV/V
Load Cell Protection Shipping Weight
500 kg
5-15V DC/AC
Load Cell Rated Output Net Weight
500 kg
IP67 27.2 kg / 60 lb
35 kg / 77 lb
29 kg / 64 lb
41 kg / 90 lb
EN-6
Defender Series Base
TABLE 2.7 SPECIFICATIONS MODEL Capacity Approved Resolution
D5RS
D6RS
D10RS
D15RS
D25RR
D30RR
5 kg / 10 lb
6 kg / 15 lb
10 kg / 25 lb
15 kg / 30 lb
25 kg / 50 lb
30 kg / 60 lb
NTEP: 5000d
OIML: 3000e
NTEP: 5000d
OIML: 3000e
NTEP: 5000d
OIML: 3000e
Safe Overload Capacity
150% of capacity
Pan Dimensions
240 x 300 mm / 9.4 x 11.8 in
Base Construction
300 x 400 mm / 11.8 x 15.7 in
Stainless Steel platform with painted steel frame and rubber leveling feet
Repeatability (std. deviation)
1d
Linearity
±1d
Load Cell Capacity
11 kg
22 kg
Load Cell Cable
50 kg
1 m L x 6-wire
Load Cell Type
2 m L x 6-wire
350 Ohm, aluminum, single point
Load Cell Excitation
5-15V DC/AC
Load Cell Rated Output
2mV/V
Load Cell Protection
IP65
Net Weight
5.9 kg / 13 lb
9.9 kg / 22 lb
Shipping Weight
8.1 kg / 18 lb
12 kg / 26.5 lb
TABLE 2.8 SPECIFICATIONS MODEL
D50RR
D50RL
D50RX
D60RR
D60RL
D60RX
Capacity
50 kg / 100 lb
50 kg / 100 lb
50 kg / 100 lb
60 kg / 150 lb
60 kg / 150 lb
60 kg / 150 lb
Approved Resolution
NTEP: 5000d
NTEP: 5000d
NTEP: 5000d
OIML: 3000e
OIML: 3000e
OIML: 3000e
400 x 500 mm 15.7 x 19.7 in
500 x 650 mm 19.7 x 25.6 in
Safe Overload Capacity Pan Dimensions
150% of capacity 300 x 400 mm 400 x 500 mm 11.8 x 15.7 in 15.7 x 19.7 in
500 x 650 mm 19.7 x 25.6 in
300 x 400 mm 11.8 x 15.7 in
Base Construction
Stainless Steel platform with painted steel frame and rubber leveling feet
Repeatability (std. deviation)
1d
Linearity
±1d
Load Cell Capacity Load Cell Cable
100 kg 2 m L x 6-wire
2.5 m L x 6-wire
Load Cell Type
2 m L x 6-wire
2.5 m L x 6-wire
350 Ohm, aluminum, single point
Load Cell Excitation
5-15V DC/AC
Load Cell Rated Output
2mV/V
Load Cell Protection
IP65
Net Weight
9.9 kg / 22 lb
19.4kg / 43lb
22.3 kg / 49 lb
9.9 kg / 22 lb
19.4 kg / 43 lb
22.3 kg / 49 lb
Shipping Weight
12 kg / 26.5 lb
22.3kg / 49lb
27.8 kg / 61 lb
12 kg / 26.5 lb
22.3 kg / 49 lb
27.8 kg / 61 lb
EN-7
Defender Series Base
TABLE 2.9 SPECIFICATIONS MODEL
D100RL
D100RX
D100RV
D150RL
D150RX
Capacity
100 kg / 250 lb
100 kg / 250 lb
100 kg / 250 lb
150 kg / 300 lb
150 kg / 300 lb
NTEP: 5000d
NTEP: 5000d
NTEP: 5000d
OIML: 3000e
OIML: 3000e
400 x 500 mm 15.7 x 19.7 in
500 x 650 mm 19.7 x 25.6 in
600 x 800 mm 23.6 x 31.5 in
400 x 500 mm 15.7 x 19.7 in
500 x 650 mm 19.7 x 25.6 in
Approved Resolution Safe Overload Capacity Pan Dimensions
150% of capacity
Base Construction
Stainless Steel platform with painted steel frame and rubber leveling feet
Repeatability (std. deviation)
1d
Linearity
±1d
Load Cell Capacity
250 kg
Load Cell Cable
2.5 m L x 6-wire
Load Cell Type
350 Ohm, aluminum, single point
Load Cell Excitation
5-15V DC/AC
Load Cell Rated Output
2mV/V
Load Cell Protection
IP65
Net Weight
19.4 kg / 43 lb
22.3 kg / 49 lb
36.8 kg / 81 lb
19.4 kg / 43 lb
22.3 kg / 49 lb
Shipping Weight
22.3 kg / 49 lb
27.8 kg / 61 lb
63.2 kg / 139 lb
22.3 kg / 49 lb
27.8 kg / 61 lb
TABLE 2.10 SPECIFICATIONS MODEL
D150RV
D250RX
D250RV
D300RX
D300RV
Capacity
150 kg / 300 lb
250 kg / 500 lb
250 kg / 500 lb
300 kg / 600 lb
300 kg / 600 lb
OIML: 3000e
NTEP: 5000d
NTEP: 5000d
OIML: 3000e
OIML: 3000e
600 x 800 mm 23.6 x 31.5 in
500 x 650 mm 19.7 x 25.6 in
600 x 800 mm 23.6 x 31.5 in
500 x 650 mm 19.7 x 25.6 in
600 x 800 mm 23.6 x 31.5 in
Approved Resolution Safe Overload Capacity Pan Dimensions
150% of capacity
Base Construction
Stainless Steel platform with painted steel frame and rubber leveling feet
Repeatability (std. deviation)
1d
Linearity Load Cell Capacity
±1d 250 kg
500 kg
Load Cell Cable
2.5 m L x 6-wire
Load Cell Type
350 Ohm, aluminum, single point
Load Cell Excitation
5-15V DC/AC
Load Cell Rated Output
2mV/V
Load Cell Protection
IP65
Net Weight
36.8 kg / 81 lb
22.3 kg / 49 lb
36.8 kg / 81 lb
22.3 kg / 49 lb
36.8 kg / 81 lb
Shipping Weight
63.2 kg / 139 lb
27.8 kg / 61 lb
63.2 kg / 139 lb
27.8 kg / 61 lb
63.2 kg / 139 lb
EN-8
Defender Series Base
Drawings
Figure 1. Defender Base Dimension Drawing.
A
TABLE 3. DIMENSIONS B C Height of Pan to Pan Width Surface of Table* 305 mm 95 mm
50 mm
E Depth Including Level Indicator 385 mm
105 mm
60 mm
530 mm
420 mm
125 mm
70 mm
580 mm
305 mm
305 mm
95 mm
52 mm
335 mm
DxxxQL, DxxxWL
457 mm
457 mm
115 mm
70 mm
487 mm
DxxxQX, DxxxWX
610 mm
610 mm
137 mm
90 mm
640 mm
DxxxRS
300 mm
240 mm
80 mm
44 mm
330 mm
DxxxRR
400 mm
300 mm
86 mm
50 mm
430 mm
DxxRL
500 mm
400 mm
86 mm
48 mm
530 mm
DxxxRX
650 mm
500 mm
110 mm
73 mm
695 mm
DxxxRV 800 mm 600 mm 120 mm *For leveling purposes, the feet may be extended up to an additional 15 mm.
83 mm
840 mm
Base
Pan Depth
DxxxHR
355 mm
DxxxHL
500 mm
400 mm
DxxxHX
550 mm
DxxQR, DxxxWR
D Height of Pan
EN-9
Defender Series Base
Accessories TABLE 4. ACCESSORIES Description
Part Number
Base Mount Kit, painted steel
80500722
Column Kit, 35 cm painted steel
80500723
Column Kit, 68 cm painted steel
80500724
Column Kit, 35 cm stainless steel
80500725
Column Kit, 68 cm stainless steel
80500726
Load Cell Cable Adapter Kit
80500736
LIMITED WARRANTY Ohaus products are warranted against defects in materials and workmanship from the date of delivery through the duration of the warranty period. During the warranty period Ohaus will repair, or, at its option, replace any component(s) that proves to be defective at no charge, provided that the product is returned, freight prepaid, to Ohaus. This warranty does not apply if the product has been damaged by accident or misuse, exposed to radioactive or corrosive materials, has foreign material penetrating to the inside of the product, or as a result of service or modification by other than Ohaus. In lieu of a properly returned warranty registration card, the warranty period shall begin on the date of shipment to the authorized dealer. No other express or implied warranty is given by Ohaus Corporation. Ohaus Corporation shall not be liable for any consequential damages. As warranty legislation differs from state to state and country to country, please contact Ohaus or your local Ohaus dealer for further details.
Ohaus Corporation 19A Chapin Road P.O. Box 2033 Pine Brook, NJ 07058-2033, USA Tel: (973) 377-9000 Fax: (973) 944-7177 With offices worldwide. www.ohaus.com
*80251421* P/N 80251421 B © Ohaus Corporation 2008, all rights reserved. Printed in China