Preview only show first 10 pages with watermark. For full document please download

Owner`s Manual Window Air Conditioner

   EMBED


Share

Transcript

Owner’s Manual Window Air Conditioner G17-10ESCWAC G17-12ESCWAC Write the model and serial numbers below for your records: Model # Serial # Date Purchased Please read the entire manual carefully to ensure proper operation of the product. To find an electronic version of this manual, please visit www.greeproducts.com Phone: 1-866-658-0466 Email: [email protected] TABLE OF CONTENTS PAGE IMPORTANT SAFETY INFORMATION.................................................................................................. 3-4 INSTALLATION INSTRUCTIONS......................................................................................................... 5-10 OPERATING INSTRUCTIONS........................................................................................................... 11-14 CLEANING & MAINTENANCE ......................................................................................................... 15-16 BEFORE YOU CALL......................................................................................................................... 17-19 WARRANTY.......................................................................................................................................... 20 NOTICE: Pictures within this manual are for reference only. Please refer to the actual product for the appearance. 2 SAFETY INFORMATION SYMBOL INDICATES A HAZARDOUS SITUATION WHICH IF NOT AVOIDED COULD RESULT IN SERIOUS INJURY OR DEATH. Please read and understand this entire manual before attempting to assemble, operate or install your window air conditioner unit. Use this air conditioner only as instructed in this manual. While this manual covers a wide variety of troubleshooting, the instructions are not meant to cover every situation that may occur. Caution and common sense are to be practiced when installing, operating or maintaining your air conditioner. We recommend 2 people to unpack and install. WARNING • Use caution when unpacking and installing. Fins may be sharp and could harm you. • Do not stop the unit by pulling out the power plug. This may cause electric shock or fire. • Replace immediately any part that has become frayed or damaged. Do not use a cord that shows damage or cracks along the length or at the connector. A damaged power cord should be replaced with a new cord obtained from the manufacturer. Please contact Customer Service for replacement options. • Do not modify power cord length or share an outlet with another appliance. This may cause electric shock or fire. • Always use a dedicated power circuit. The voltage on the outlet should match the voltage rating on the rating plate. • The power cord is equipped with a 3-prong grounding plug which can only be used with
a standard 3-prong wall outlet to minimize
the possibility of electric shock hazard. Where a 2-prong outlet is encountered, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet. • Do not use the outlet if it is loose or damaged. It may cause electric shock. • Do not open the unit during operation. It may cause electric shock. 
 • Keep away from heating appliances, flammable gas, or combustibles such as gasoline, benzene, thinner, etc. 
 • Ventilate room before operating air conditioner if there is a gas leak from another appliance. • Never use an extension cord, surge protector, or multi-outlet adapter with this unit. • Plug in power cord properly. Always unplug your air conditioner by pulling on the power plug. Grip plug firmly and unplug to remove. 
 • Do not disassemble or modify the unit. 
 • Do not operate with wet hands. • Do not clean with water that may run inside the units electrical parts. This may cause failure of the machine or electric shock. 
 • Do not place obstacles around air-inlets or inside of air-outlet. 
 • Switch off the unit and unplug the unit before cleaning. 
 • To prevent injury, when the air filter needs to be removed, do not touch the metal parts of the unit. 
 • Only clean outside of the unit, use only a mild detergent.
 • The filter(s) should be checked once a month, or every 250 hours, to see if cleaning is necessary. Always insert the filters securely. • Do not place heavy objects on the power cord. Ensure that the power cord is not compressed. • Turn off the main power switch when not using the unit for a long period of time. • All air conditioners contain refrigerants which, under federal law, must be removed prior to disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do. • These R410A air conditioning systems require contractors and technicians to use tools, equipment and safety standards approved for use with this refrigerant. 3 SAFETY INFORMATION Electrical Information The power cord with this air conditioner contains a current detection device designed to reduce the risk of fire. Please refer to the section “operation of current device” for details. In the event that the power cord is damaged, it cannot be repaired. It must be replaced with a power cord from the product manufacturer. • The power cord is equipped with a 3-Prong Grounding Plug which Do not under any circumstances cut, remove, or bypass the grounding prong Power Cord with 3-Prong Grounding Plug and Current Detection Device. can only be used with
a standard 3-prong wall outlet to minimize
the possibility of electric shock hazard. Where a 2-prong outlet is encountered, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet. 
 • Do not use a power cord that shows damage or cracks along the length or at the connector. A damaged power cord should be replaced with a new cord obtained from the manufacturer. Please contact Customer Service for replacement options. 
 • Do not modify power cord length or share an outlet with another appliance. This may cause electric shock or fire. 
 • Always use a dedicated power circuit. The voltage on the outlet should match the voltage rating on the rating plate. 
 • Do not use the outlet if it is loose or damaged. It may cause electric shock. 
 • Never use an extension cord, surge protector, or multi-outlet adapter with this unit. Operation of Current Device The power cord contains a current device that senses damage to the power cord. To test your power cord, do the following: 1. Plug in the Air Conditioner. 2. The power cord has TWO buttons on the 3-Prong Grounding Plug. Press the TEST button. You will notice a click as the RESET button pops out. 3. Press the RESET button, and you will hear a click as the button engages. 4. The power cord is now supplying electricity to the unit. (On some products this is also indicated by a light on the 3-Prong Grounding Plug). NOTE: • Do not use the power cord to turn the unit on or off. • Always make sure the RESET button is pushed in for correct operation. • The power cord must be replaced if it fails to reset when either the TEST button is pushed, or it cannot be reset. Please contact Customer Service. • If the power cord is damaged, then it cannot be repaired. It MUST be replaced with a new power cord.  Please contact Customer Service. NOTE: If you turn off the air conditioner, wait at least three MINUTES before turning it back on. This prevents the unit from blowing a fuse or tripping a circuit breaker. 4 INSTALLATION INSTRUCTIONS Before You Begin CAUTION When handling the unit be careful to avoid cuts from any sharp metal edges and the aluminum fins on the front / rear coils. IMPORTANT: Save these instructions for future reference. Product failure due to any improper installation is not covered under the One Year Limited Warranty. IMPORTANT: You MUST use the parts provided for installation as well as proper installation procedures as described in this manual when installing this unit. • • • • • • WARNING Observe all electrical governing codes and ordinances. 
 Do not use damaged or non-standard power cords. 
 Use caution during installation and maintenance. Use proper operation to prevent electric shock, casualty and other accidents. Proper installation is the responsibility of the installer. If not installed properly the warranty is void. 
 All parts described must be used with no substitutions. Selection of Installation Location Installing the unit in the following places can be dangerous and may cause malfunction: 1. Areas with strong heat sources, vapors, flammable or explosive gas, sulfated gas or volatile objects spread in the air. 2. Near high-frequency devices such as welding machines, medical equipment, etc. Requirements for Electric Connection 
 • Follow the Electric Safety Information when installing the unit. 
 • According to your local safety regulations, use a qualified power circuit. 
 • Do not plug into an outlet if it is loose or damaged. It may cause electric shock. 
 • P  lease make sure the power supply complies with the requirement of air conditioner. Unstable power supply or wrong wiring may lead to electric shock, hazard or malfunction. Note: Electricity requirements are 115V (60 Hz). • Do not connect to the power outlet before finishing installation. 
 • Please make sure the outlet is always grounded effectively, otherwise it may cause electric shock. The grounding resistance should comply with national electric safety regulations. 5 INSTALLATION INSTRUCTIONS Where to Install the Unit • Ensure there is no obstruction near the air-inlet or air-outlet. 
 • Select a window where the condensation water can be dispersed easily out the back of the unit and won’t affect others. 
 • The window should be able to withstand the weight of the unit. 
 • Select a window where noise and outflow air emitted by unit will not affect others. 
 • Select a window out of reach of children and animals. 
 NOTE: • The description for installation is for the standard vertical double hung window. • If you need to install the air conditioner in a narrow window, you may not need to use the Flexible Screen sub-assembly. Please refer to requirement of window size for details. • All parts must be secured to firm wood, masonry, or metal. • The electrical outlet must be within reach of the power cord. • Refer to the dimensions in the illustration. cm W: 61 cm – 101.6 (24” – 40”) ”) min H: 45.8 cm (18.06 STORM WINDOW A storm window frame will not allow the air conditioner to tilt toward the outside, and it will prevent the unit from properly draining. To adjust for this, attach a piece of wood (not included) to the window sill. Wood Piece: Width: 5.1 cm (2”) Length: Long enough to fit inside the window frame Thickness: To determine the thickness, place a piece of wood on the window sill to make it 1.3 cm (1/2”) higher than the top of the storm window frame or vinyl frame. Attach securely with nails or screws (not included). 6 5.1 cm (2”) 1.3 cm (1/2”) Storm window Frame piece of wood INSTALLATION INSTRUCTIONS Parts and Tools Needed Upper Guide Rail Location* Air-Outlet Frame Control Panel Fan Direction Adjusting Rod Air-Inlet Panel Power Cord Power Plug *Upper guide rail may be attached on some units Parts List Window Unit Flathead screwdriver Flexible Screen (2) Window Sill And Sash Seal (With Adhesive) (2) Upper Guide Rail Foam Top Gasket (Without Adhesive) Top Mounting Rail Seal Strip Flexible Screen Panel Seal (2) Foam Insulation (2) AAA Batteries Remote Control 7 Fixed Bracket for Window (1) Type A Screws (4) Type B Screws (6) Frame Locking Bracket (2) INSTALLATION INSTRUCTIONS Upper Guide Rail 1 Top Mounting Rail Seal Strip Upper Guide Rail* 2 Note: For safety, all four screws must be SECURELY fastened. Remove backing from seal strip To install the Upper Guide Rail, peel off the back side of the Top Mounting Rail Seal Strip and align it on the bottom edge of the upper guide rail. Press the Top Mounting Rail Seal Strip onto the Guide Rail to fully seal. 3 Use 4 Type A Screws to attach the Upper Guide Rail onto the outer case of the air conditioner unit. *Upper guide rail may be attached on some units 4 Flexible Screen Seal Flexible Screen A Left Left Frame Right Right Upper Guide Rail B Before installing the Flexible Screens, place one Flexible Screen Seal on the left side of the LEFT screen and right side of the RIGHT screen as shown. Frame To install the Flexible Screens, ensure that the sides marked LEFT and RIGHT are installed into the left and right side of the unit. Lower Guide Rail A) Hold Frame with one hand while extending Flexible Screen with other hand. Slide edge of Flexible Screen into track on side of unit. B) Slide the upper and lower ends of the Flexible Screen Frame into the Upper and Lower Guide Rails. NOTICE: This picture is for reference only. Please refer to the actual product for the appearance. 8 INSTALLATION INSTRUCTIONS NOTE: Top Rail and sliding panels at each side are offset to provide the proper pitch to the rear of .8 cm (5/16”). This is necessary for proper condensed water utilization and drainage. If you are not using the side panels for any reason, this pitch to the rear must be maintained. 5 6 Front View Window Sill & Sash Seal (With Adhesive) Horizontal or inclined about 3° To install the Window Sill & Sash Seal, cut the seal to fit the length of the window. Peel off the backing, and attach to window sash and window sill. Side View BACK Note: To install the air conditioner onto the window sill, it is recommended to use 2 PEOPLE. 7 Window Frame FRONT Lower Guide Rail Place the air conditioner on the sill with the Lower Guide Rail against the back edge. Center the unit, and close the window securely behind the Upper Guide Rail. The unit should be slightly tilted to the outside. Use a level: about 1/3 bubble will show correct slant. Screws Window Sash Window Sill Left Upper Guide Rail 8 Vinyl Window Right Frame Locking Brackets (2) Note: In order to prevent the window sill from splitting drive the pilot holes before inserting the screws. Wooden Window Extend the left and right Flexible Screens to the window sashes. Attach 3 Type B Screws in holes in the upper panel. Install the Frame Locking Brackets between the bottom of the Flexible Screen and the window sill, attach with 2 Type B Screws. To install the fixed bracket, attach the bracket to the window side sash with one Type B Screw. This prevents broken glass or damage to the windows. NOTICE: This picture is for reference only. Please refer to the actual product for the appearance. 9 INSTALLATION INSTRUCTIONS 9 10 Width Foam Top Gasket (Without Adhesive) Insert the Foam Top Gasket between the glass and the window to prevent air from getting into the room. If the strip does not properly fit to your window, obtain appropriate material at a local store to provide a proper seal. Width After finishing installation, measure the width between the outer case of the air conditioner and the window frame (see Figure 10, length). Note: Be sure to measure each screen, as the length could be different on each side. 11 12 Width Locate the Foam Insulation from the packaging. Cut the insulation into a rectangular shape to match the width as measured in figure 10. Remove adhesive from back of Foam Insulation. Stick the installation evenly on the flexible screen. Cover the flexible screen completely. NOTICE: This picture is for reference only. Please refer to the actual product for the appearance. 10 OPERATING INSTRUCTIONS Features of Your Window Air Conditioner i-Feel LCD Remote Control The remote acts as a separate thermostat for enhanced comfort. The mini thermostat in the remote control can sense its surrounding temperature and transmit the signal back to the unit. The unit will cool the room until the desired temperature is met at the location of the remote. Maximum transmission distance of remote from unit is 8 m (26 ft).  rogrammable Digital Thermostat P For precise comfort control. Select the exact desired temperature for maximum comfort.  4 Hour Programmable Clock Timer 2 While in OFF mode enables user to set a specific time for the unit to turn on. When in ON mode, enables user to set a specific time for unit to turn off.  Speed Fan & Auto Fan 3 Allows more settings for maximum comfort. Auto fan automatically sets the fan speed based on the current room temperature and thermostat setting Evaporative Dehumidifier (Dry Mode) Reduces and evaporates unwanted moisture without extra cooling. Sleep Mode Automatically increases the set temperature 2° after the first hour and another 2° after the second hour. This feature limits compressor usage and conserves energy. Energy Saver Mode Automatically shuts off both compressor and fan when desired temperature is reached, to conserve energy. Loss of Power Protection with Auto Restart Remembers all settings when power is interrupted. As soon as power is restored, the A/C will operate in the mode, temperature and settings prior to power loss. Gold Shield Anti-corrosion coating prevents condenser fin corrosion. NOTE: The default temperature reading on the display is degree Fahrenheit (°F). To change the display to degree Celsius (°C), press the Mode and Temp Decrease buttons together and hold for 3 seconds when the remote is turned off. Repeat the process to change back to degree Fahrenheit (°F). This cool-only air conditioner was not designed for freezing outdoor conditions. Do not use in freezing outdoor conditions. 11 OPERATING INSTRUCTIONS Function & Control Display 7 Light indicates the unit is in the temperature or delay Time Set Mode Temp/Time Set 6 Cooling indicator SE indicatorfan Fan indicator Dry indicator 5 4 1 Filter Check Timer POWER Cool Energy Saver Fan Only Dry Mode Auto High Med Low Fan Speed Auto speed indicator High speed indicator Medium speed indicator Low speed indicator 3 2 REF# 1 BUTTON FUNCTION Power Turns air conditioner On and Off. 2 Mode Press this button to select a mode from the following options: AUTO - COOL - ENERGY SAVER - FAN - DRY 3 Fan Speed  4 Timer 5 Filter Check 6 ▲ ▼ Press this button to select desired fan speed: AUTO - LOW - MED - HIGH Timer can be set in 0.5 hour increments, below 10 hours. Timer can be set in 1 hour increments, above 10 hours. Range is 0.5 to 24 hours. ON: Timer can be set when unit is OFF. When timer reaches ON, the unit will turn on. OFF: Timer can be set when unit is ON. When timer reaches OFF, the unit will turn off. This light will appear when unit has operated for 250 hours. Clean filter per Maintenance section. After filter is cleaned, press Filter Check button to clear. COOL or ES Mode: Use to set temperature. Pressing (▲) or (▼) button once will increase or decrease set temperature by 1°F. TIMER Mode: Use to increase/decrease time increments by 0.5 hours. DESCRIPTION FUNCTION Auto Fan Mode In this mode, fan speed will automatically adjust to provide optimum comfort with the set temperature. Cannot be used when in FAN only mode. Cool Mode Energy Saver Mode Fan Only Mode Dry Mode Display Air conditioner operates under COOL mode. Cooling indicator will be on. Press Fan Speed button to adjust the fan speed. Air conditioner operates under ES mode. ES indicator will be on. Press Fan Speed button to adjust the Fan speed. Fan Speed button to adjust the Fan speed. Air Conditioner does not cool in this mode. Unit runs in low fan speed for dehumidification. DRY Mode indicator will be on. Fan speed cannot be adjusted. Shows the room temperature or time remaining on the Delay Timer. Shows the room Temperature while setting the temperature in COOL, DRY*or ENERGY SAVER modes. 12 OPERATING INSTRUCTIONS Remote Control Operation NOTICE: •  The distance between remote and receiving window should be no more than 8 m (26 ft.), and there should be no obstacles between them. • When not using the remote control for extended periods of time, please take out the batteries. DESCRIPTION ON/OFF Button Mode Button -/+ Fan Button FUNCTION Turns air conditioner On and Off. Turning on the unit with remote controller, the unit will operate in ENERGY SAVER mode. Press the button to select a mode from the following options: AUTO - COOL - ENERGY SAVER - FAN - DRY Press (+) or (-) button to increase or decrease set temperature by 1ºF. Hold (+) or (-) button for 2 seconds to quickly adjust the temperature. In AUTO Mode, set temperature is not adjustable. This button is used for setting Fan Speed in the sequence that goes from AUTO — LOW — MED— HIGH Sleep Button Press this button to operate in SLEEP mode. Press it again to cancel. This function is available in COOL, DRY and ENERGY SAVER mode to maintain the most comfortable temperature. Timer Button Press this button to initiate AUTO-ON/AUTO-OFF timer Press this button twice to cancel auto-timer i-Feel Button i-Feel function will activate after pressing this button. This will work with the rooms ambient temperature, sending the remote programmed thermostat temperature to the unit every 10 minutes If power is lost this function will need to be reset. Speed Lock Feature This shows Fan Speed in the sequence that goes from AUTO — LOW — MED— HIGH Press (+) or (-) button to LOCK or UNLOCK the keyboard. 13 OPERATING INSTRUCTIONS Air Flow Adjustment Adjust the air frame left or right to direct the air flow according to the user’s preference. Air outlet frame Adjust the air frame up or down to direct the air flow according to the user’s preference. NOTICE: This picture is for reference only. Please refer to the actual product for the appearance. 14 CLEANING AND MAINTENANCE WARNING • Turn off the air conditioner and disconnect the power cord from outlet before cleaning the air conditioner to avoid electric shock. • Do NOT wash the air conditioner with water to avoid electric shock. • Do NOT use harsh cleansers to clean the air conditioner. • To prevent injury, when the air filter needs to be removed, do not touch the metal parts of the unit. Cleaning the Filter • To open the panel, pull the grooves at both sides of the panel to open the panel to the angle shown in Fig. 1. • Remove and clean the filter by using a duster or a damp clean cloth. If the filter is dirty, you can use warm water with mild soap, lay to dry. Do not use hairdryer or other any other drying device. • Once filter is completely dry, re-install the filter, and then close the panel cover tightly as shown in Fig. 2 Front Panel Fig. 1 • Do not operate the air conditioner when the filter is not installed. Maintenance • Check the filter once every month or approximately 250hrs of use, to see if cleaning is necessary. If there is a lot of dust in the operation environment, then clean more frequently. Front Panel Fig. 2 • D  o not touch the metal fins in the air conditioner when removing the filter. • To clean panel surface, wipe with a soft dry cloth. • Check the coils on the outdoor side of unit periodically to ensure they are not clogged with dirt or debris. NOTICE: Filter This picture is for reference only. Please refer to the actual product for the appearance. 15 CLEANING AND MAINTENANCE Remote Control Battery Replacement AAA Battery Signal Sender Reinstall Remove Battery Cover Replacement of Batteries in Remote Control 1. Press the back side of remote control marked with OPEN, as shown in the figure, and then push out the BATTERY COVER of battery box along the arrow direction. 2. Replace two (AAA 1.5V) dry batteries, and make sure the position of “+” polar and “-” polar are correct. 3. Reinstall the BATTERY COVER of battery box. 16 BEFORE YOU CALL WARNING If the below errors occur, please turn off the air conditioner and disconnect the power cord from the outlet immediately. Please contact Customer Service at once. • Power cord is overheating or damaged. • Abnormal sound during operation. • Burning smell. • Power cord test or reset button often bounces automatically. • Water leakage at front of unit. Do not attempt to repair or refit the air conditioner. Operating the air conditioner under these conditions can cause further malfunctioning, electric shock, or a fire hazard. NORMAL SOUNDS The below describe normal sounds, you may hear while operating your air conditioner. These are not malfunctions of the unit. Contact Customer Service with any malfunction questions. High Pitched Sounds: The high efficiency compressor may make a high pitched noise during the cooling mode. Vibrating Sounds: If the unit isn’t installed properly or if the wall or window construction is poor, the unit may vibrate and make noise. Gurgling or Hissing Sounds: You may hear these sounds when the refrigerant is passing through the evaporator. Pinging or Droplet Sounds: When droplets of water hit the condenser during normal operation it may cause pinging or droplet sounds. 17 BEFORE YOU CALL Malfunction Code If any of the following Malfunction Codes appear, please call Customer Service. MALFUNCTION CODE SOLUTION F1 F2 F4 FJ EP Please contact Customer Service. F0 H3 E2 E8 JF IF THESE SOLUTIONS FAIL, PLEASE CALL 1-866-658-0466 FOR GREE CUSTOMER SERVICE 18 BEFORE YOU CALL : PROBLEM SOLUTION Wall plug is not properly connected. Push plug firmly into the wall socket. Air conditioner will not operate Plug current device is tripped. Press RESET button (located on the power cord plug). House fuse is blown and/or tripped. Check circuit breaker/replace fuse. Room temperature is below 60 ºF (16 ºC). Cooling may not occur if room temperature is below 60 ºF (16 ºC). Make sure nothing is obstructing the unit; furniture, curtains, blinds. Air from unit does not feel cold enough Check for open furnace registers or cool air returns. Make sure filter is clean. (see Maintenance section) RESET unit. Adjust temperature to lower setting. Compressor shut off due to changing modes. Wait 5 minutes, compressor will turn back on when unit is set on COOL mode. Room is not cooling- ice forming on back of unit On models with touch pad controls set the unit at High FAN mode or High COOL mode and adjust the thermostat to a higher temperature. Air restricted due to dirty air filter. Remove filter(s) and clean. Temperature is set too high. Turn temperature setting down. Room is not cooling- no ice on back of unit Air louvers are not adjusted properly. Check and adjust louvers to direct air flow. Air ventilation is blocked/ hindered. Remove any object blocking air flow/ (drapes, blinds, furniture etc.). Other doors and/or windows open allowing cool air to escape room. Air conditioner rapidly turns on and off Unusual noise when unit is cooling Air restricted due to dirty air filter. Remove filter and clean. See “Normal Sounds” Sections Window vibrations: improper installation. Refer to Installation Instructions. Water dripping inside when unit is cooling Improper installation. Refer to installation instructions. Water dripping outside when unit is cooling Unit is removing a large quantity of moisture from the room. This occurrence is normal in excessively humid, hot weather. Remote sensing deactivating (some models) Remote control is outside of range of the unit. Place remote within 8 m (26 ft.) of the unit. Remote control signal is obstructed- remove any item blocking front of unit. Low batteries. Replace batteries on remote control. IF THESE SOLUTIONS FAIL, PLEASE CALL 1-866-658-0466 FOR GREE CUSTOMER SERVICE 19 WARRANTY STATEMENT One Year Limited Warranty In order to make your Warranty Claim: Please call 1-866-658-0466 or email us at [email protected] This product is warranted for a period of 1 year after date of purchase. Customer must possess this Warranty Statement along with a copy of the original receipt of purchase, serial number and date of purchase. Warranty only covers new products purchased from authorized dealers or retailers. It does not include used, salvaged, refurbished products or unauthorized Internet sales. THIS WARRANTY DOES NOT COVER: Commercial use. Damage done to the unit while in possession of the consumer; not caused by a defect. Damage caused by improper installation, delivery, maintenance and failing to follow the proper instructions provided by the manual. Damage caused by modifications to the product or unreasonable use. Damage caused by replacement of house fuses or resetting circuit breakers. Damage caused by repairs or alterations. Damage caused after delivery. Labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of either defective parts, or replacement parts, or new units. Exclusion of Implied Warranties: GREE is not responsible for any consequential or incidental damages. GREE’s liability will not exceed the retail value of the Air Conditioner unit. This warranty does not cover, and is not intended to exclude any liability on the part of GREE, whether under this warranty or implied by law for any indirect or consequential damages for breach of warranty. Some states may not allow the exclusion or limitation so this limitation may not apply to you. For your own records, please attach a copy of your sales receipt to this manual. Also, please fill in the below: Retailer: Model #: Purchase Location: Purchase Date: Serial Number: Register your product at: www.greeproducts.com 20 Gree Customer Service Hours: 9am–5pm CST Monday–Friday Phone: 1-866-658-0466 Email: [email protected] Website: www.greeproducts.com M011817-1012ECWAC 21