Preview only show first 10 pages with watermark. For full document please download

Ozd Modbus Plus G12 - L-com

   EMBED


Share

Transcript

Hirschmann Automation and Control GmbH OZD Modbus Plus G12 Industrial Networking:FiberINTERFACES:Field Bus:Modbus Plus Fiberoptic Repeaters Product description Description Port type and quantity Type Order No. Electrical interface Signal type Bit rate Signal delay time (optional input/output) Input/output signal Length of Modbus cable Connection capability Terminator Galvanic isolation Optical interface Wavelength Launchable optical power in multi-mode fiber (MM) 50/125 Launchable optical power in multi-mode fiber (MM) 62.5/125 Launchable optical power in multi-mode fiber (MM) HCS 200/230 Optical input power Cascadibility More Interfaces Power supply Signaling contact Network size - length of cable Multimode fiber (MM) 50/125 µm Multimode fiber (MM) 62.5/125 µm Multimode fiber HCS (MM) 200/230 µm Power requirements Operating voltage Current consumption Power consumption Redundancy Redundancy functions Displays LED red/green (system) LED green/orange (Port 1) LED green/orange (Port 2,3) Ambient conditions interface converter electrical/optical for Modbus Plus-field bus networks; repeater function; for quartz glass und PCF (HCS) FO; approval for Ex-zone 2 (Class 1, Div. 2) 2 x optical: 4 sockets BFOC 2.5 (STR) 1 x electrical: Sub-D 9-pin, female, pin assignment according to Modbus PlusStandard OZD Modbus Plus G12 943 740-021 Modbus Plus 1 Mbit/s <1 µs Modbus Plus Bus 100 m max. 31 terminal devices external shielding/housing: no; data lines/housing: yes 860 nm -15 dBm -14 dBm -10 dBm min. -25 dBm, max. -3 dBm not limited 5-pin terminal block, screw mounting 5-pin terminal block, screw mounting 2300 m 10 dB link budget at 860 nm; A = 3 dB/km, 3 dB reserve 2300 m 11 dB link budget at 860 nm; A = 3.5 dB/km, 3 dB reserve 1500 m 16 dB link budget at 860 nm; A = 8 dB/km, 3 dB reserve 24 VDC -20% ... 48 VDC +10% non-interchangeable, safety extra-low voltage 120 mA at +24 VDC; 65 mA at + 48 VDC 3.1 W HIPER-Ring (ring structure), redundant 24 V infeed monitoring operating voltage and data traffic differentiated monitoring electrical channel differentiated monitoring optical channels page 1 of 2 Operating temperature Storage/transport temperature Relative humidity Mechanical construction Dimensions (W x H x D) Mounting Weight Protection class Housing material EMC interference immunity EN 61000-4-2 electrostatic discharge (ESD) EN 61000-4-3 electromagnetic field EN 61000-4-4 fast transients (burst) EN 61000-4-5 surge voltage EN 61000-4-6 conducted immunity EMC emitted immunity EN 55022 Approvals Issued approvals Scope of delivery and accessories Scope of delivery Accessories to order separately 0 °C to +60 °C -40 °C to +70 °C <95% (non-condensing) 40 x 111 x 73.5 mm DIN rail or mounting plate 620 g IP 40 die-cast zink contact discharge: 4 kV, air discharge: 8 kV 10 V/m (80 - 1000 MHz) power line 2 kV, data line: 1 kV power line 0.5 kV (line/line, line/earth), data line: 1 kV 10 V (0.15 - 80 MHz) EN 55022 limit class A cUL Class 1, Div.2; C-Tick device, start-up instructions manual, order no. 933 989-901 page 2 of 2