P1-56 Covers

   EMBED


Share

Transcript

VRF _  *   ;  Multi Zone Heat Pump System for Buildings Large Capacity Zoned VRF System DC Inverter Controlled Compressor Long Piping System Design High Efficiency R410A Refrigerant Fujitsu General creates high-quality and environmentally-friendly products that provide a comfortable environment by using the air conditioning technology, innovation and creativity which we developed over 35 years ago. High Reliability High Efficiency V series More Comfort Multiple condensing units on a single S series 8 Tons / Heat recovery refrigerant circuit 8 Tons / Heat recovery 6, 8 Tons / Heat pump provides greater capacity. & Heat pump 6, 8 Tons / Cooling 2001 VRF System 2003 2006 Green Initiatives Fujitsu introduces Inverter technology and the use of R410A refrigerant. Easy Installation Easy Service & Design Versatility Maintenance TABLE OF CONTENTS FEATURES AIRSTAGE History Design Versatility .......................................... 5 Easy Installation ........................................... 6 High Reliability ............................................. 7 Comfort & Convenience ............................... 8 Easy Service & Maintenance ....................... 9 FUJITSU GENERAL’s VRF AIRSTAGE Series has been developed based on our long-term air-conditioning technology know-how and was first provided 10 years ago. We have offered a series of products for large homes to large-scale buildings to meet the various market needs. MODEL LINEUP Indoor and Outdoor Model Table ................. 10 OUTDOOR UNITS Energy Saving Features ............................ 12 Dimensions & Specifications ....................... 13 INDOOR UNITS 60Hz 6 to 24 Tons / Heat pump 100% Inverter driven For USA and Latin America V-II series New 4-face heat exchanger reduces unit size and increases efficiency. 2009 2010 2012 RoHS Compliant Green Advancement Restriction of Hazardous Substances is an EU directive intended to protect the environment by forcing manufacturers to use environmentally friendly materials in all consumer electronics. Use of 100% Inverter driven DC compressors. High Quality Development and Production Environment The Headquarters-JAPAN R&D Center is equipped with a wide range of testing equipment envisioning a variety of operating conditions. This i n c l u d e s a t e s t i n g t o w e r w i t h a 1 9 8 f t . ( 6 0 m ) h e i g h t d i ff e r e n c e f o r buildings.We provide high quality & reliable products that meet the Compact Cassette ....................................... 14 Cassette ......................................................16 Slim Compact Duct ..................................... 18 Duct ............................................................ 20 High Static Pressure Duct ........................... 22 Floor/Ceiling ................................................ 24 Ceiling ......................................................... 26 Compact Wall Mount ................................... 28 Wall Mount .................................................. 30 CONTROLLERS Comparison Table of Controllers .................. 32 Summary of Software, Controllers, Converters & Adapters, Service & Monitoring Tools ...................................... 33 Central Remote Controller ........................... 36 Touch Panel Controller ................................ 38 System Controller ........................................ 40 Control System Diagram .............................. 42 SOFTWARE Airstage Portal ............................................. 43 Service Tool ................................................ 44 Design Simulator ......................................... 46 Building Information Management ............... 48 customers' needs from all over the world through this advanced R&D center and 6 factories based in China and Thailand. OPTIONAL PARTS Auto Louver Grille Kit .................................. 49 Connection Units, Duct Models ................... 50 Cassette, Ceiling ......................................... 51 JAPAN R&D center and 198 ft. (60m) height testing tower Central R&D center for global air conditioner development. Advanced products are developed and next generation technologies are researched. FUJITSU GENERAL CENTRAL AIR-CONDITIONER(WUXI)CO.,LTD (China) VRF Main factory. ISO9001 and ISO14001 certified. This factory has high quality and high reliability system for manufacturing VRF system. APPLICATIONS Medical and Healthcare Facilities ................ 52 Educational and Religious Facilities ............ 53 Multi-Tenant Dwellings ................................. 54 Office Buildings and Retail Spaces .............. 55 Variable Refrigerant Flow System For Small and Large Buildings †(‡     \ XU&  †K     ;   @S?ˆ †SS          > ; †" UZ     _*;  †&      ;           XU  †Z‰Š ‹  [‰Š K  Œ  ; Œ  ;     †(‡       (  +   K    9   \& Q& 4 VRF VRF 9 _  ; World’s longest total pipe length 3,280 ft. max. Overall piping length 3,280 ft. Ž    between outdoor and indoor units +      164 ft. max. 492 ft. max.                 M@S@  ‡ ‹                  unit 196 ft. max. Ž    between indoor and indoor units 49 ft. max. High static pressure Wide operating range”@ &            ;       SX Œ'Q?‹   &                  %                      .32 in.WG as standard V-II series Installation Example K  MŽ  M Z‘@@Z’‰@ZK‘U\K“‰U‘[?’‰X?K‘X@K“ ”X ’“ ’K“ K   @XX Z? 115°F (46°C ) @?U U? Q\ S? Ž   70°F (21°C ) \Q X? Z? @? SX ? 23°F (-5°C ) @U ‰@? ‰U ‰X? 5°F (-15°C ) -4°F (-20°C ) /     9K       ‡     SX Œ'Q?‹  ”@_*Ž ‹;  ):&    Ž   K  ;     Ž    :*K    ”X:           •    \ Q           ‡   Z’‰@ZK“ 5 Easy Installation Easily transported Easily craned into position using lifting belt hooks Easy access Can be transported in a small elevator By adopting an L-Shape front panel that can be removed, the work space for installation and service has been greatly expanded by this design. For multiple installations, work is performed easily and efficiently even in a narrow space. Design of outdoor unit allows for lifting straps to be used Slots in base of the unit allow for easy transportation by forklift. High capacity connection Simple signal line connection Communication wiring can be connected continuously to any component, making installation easier. Up to maximum 11,811 ft / 3,600 m length Various combinations from 6 Tons to 24 Tons with 33 indoor unit models, 9 types, can be selected. A minimum of 50% to a maximum of 130% indoor unit connectable capacity. Connectable indoor unit capacity Ratio up to 130 % Connectable indoor unit number up to 45 Wide variety of indoor units 9 Other wiring method types, 33 models Simple wiring method Note: When total indoor unit capacity is greater than 100%, individual indoor units will operate at a slightly lower capacity when maximum capacity is required. Automatic address setting Automatic address setting is performed at outdoor unit The address of each indoor unit can be automatically set by the touch of a button on the outdoor unit. Addresses are automatically distributed from outdoor unit. Note: In a multiple refrigerant system installation there could be a case where Automatic addressing sequence cannot be initiated. Press the pushbutton switch of outdoor unit. 6 3 7 1 0 2 4 5 6 Manual address setting from indoor unit and remote controller is also possible. VRF High Reliability Life-extending operation Outdoor unit operation rotation The compressor starting order is rotated so that the running time is shared. Rotation Rotation DC D C 2 DC 1 Rotation DC DC 1 DC DC 3 DC 2 DC DC 1 D DC C 3 DC 3 DC DC 2 Note: The inverter compressors start in priority. Rotate operation is alternated by the start / stop timing of the compressors. Oil return design Refrigerant circulation control Individual oil separator and intelligent oil feedback operation logic are adopted. Oil return pipe of oil separator is connected directly to the compressor suction line through capillary and through solenoid valve. Innovative compressor control logic balances refrigerant mass flow rate of each outdoor unit by controlling inverter speed. Oil separator Strainer Load Level Compressor Capillary tube Oil Solenoid valve ON ON OFF ON ON ON DC 1 DC 2 DC 3 DC 1 DC 2 DC 3 Master Slave 1 Slave 2 Master Slave 1 Slave 2 Unbalanced operation condition Balanced operation condition Refrigerant Compressor under operation Adoption of blue fin heat exchanger Liquid back flow protection Blue fin treatment to the outdoor unit’s heat exchanger improves corrosion resistance. By adopting a large sized accumulator, the refrigerant which is not completely vaporized is left inside the accumulator and only a stable supply of gas is fed from the accumulator. Blue fin heat exchanger Cobalt Blue protection Standard chromate protection Aluminium base material Hydrophilic coating Compressor Accumulator From Evaporators Large Sized Accumulator Compressor Additional Accumulator 7 Comfort and Convenience Centralized Control It is possible to manage the operation and comfort of an entire building by using a Fujitsu VRF Control System. Controllers can be selected to meet the number of indoor units and control requirements of the occupants. Touch Panel Controller Central Remote Controller System Controller Quiet operation Low noise mode: Two low noise modes can be selected automatically using quiet priority setting or capacity priority setting, depending on the usage environment and outside temperature load. Quiet priority setting Air conditioning load factor Capacity priority setting Heat load Heat load 100% down Capacity 100% 0 0 Rated noise level Rated noise level Operating sound 0 Alternated automatically 0 time Reset automatically Quiet priority low noise mode time Capacity priority low noise mode Remote monitoring The Web Monitoring system allows you to view system operation at all times over the internet ensuring trouble free operation. Low noise design: Compressor noise has been significantly reduced by shielding the compressor compartment. Compressor compartment Monitoring Side VRF Network System Side Outdoor unit Transmission line Internet or Public Telephone Line USB adaptor (Included) Web Monitoring Tool Non-stop oil recovery operation A comfortable room condition is maintained during oil recovery mode because the product continues to operate without stopping the cooling or heating operation. 8 Indoor unit The operating VRF network system in the building can be monitored in real time over the Internet. VRF Easy Service & Maintenance Designed for easy service and maintenance Inspection and replacement of main parts is easy due to innovative construction and an LED operational display. Easy-to-read 7-segment LED display which explains operational and trouble status Consolidated electrical components make maintenance easy Movable PCB panel that allows for easier maintenance work behind the PCB Split front panel allows for maintenance from top or bottom of the outdoor unit Maintenance of electrical components, valv val va ve and compressor parts from the ves valves, fro front is possible. Error status can be checked easily via the indoor unit wired controller Wired Remote Controller Simple Remote Controller Faulty unit number (Remote controller address) Error code An error code is displayed on a liquid crystal screen. Remote controller address Error code SU MO TU WE TH FR SA Emergency stop function Emergency alarm can be received by indoor or outdoor units, Central Remote Controller or Touch Panel Controller. All units will be stopped when emergency alarm signal is received. Note: In case of received emergency alarm by indoor/outdoor unit: All units connected within same refrigerant system will be stopped. Central Remote Controller/Touch Panel Controller: all units connected within VRF network system with Central Remote Controller/Touch Panel Controller will be stopped. Emergency stop function Touch Panel Controller Emergency stop function Emergency stop function 9 Outdoor units lineup 96,000 BTU (8 Tons) 28.1kW (10HP) 144,000 BTU (12 Tons) 42.2kW (16HP) 168,000 BTU (14 Tons) 49.2kW (18HP) AOUA72RLBV AOUA96RLBV AOUA144RLBVG AOUA168RLBVG AOUA192RLBVG UNIT : AOUA72RLBV UNIT : AOUA96RLBV UNIT : AOUA72RLBV UNIT : AOUA72RLBV UNIT : AOUA72RLBV UNIT : AOUA96RLBV UNIT : AOUA96RLBV UNIT : AOUA96RLBV 72,000 BTU (6 Tons) 21.1kW (8HP) 192,000 BTU (16 Tons) 56.2kW (20HP) Indoor units lineup Capacity range (Btuh) 7,000 9,000 12,000 14,000 AUUA7RLAV AUUA9RLAV AUUA12RLAV AUUA14RLAV ARUL9RLAV ARUL12RLAV ARUL14RLAV ABUA12RLAV ABUA14RLAV ASUA12RLAV ASUA14RLAV Compact Cassette 1 Cassette 2 Slim Compact Duct ARUL7RLAV Duct High Static Pressure Duct Floor / Ceiling Ceiling Compact Wall Mounted ASUA7RLAV ASUA9RLAV Wall Mounted 10 1 Compact Cassette Grille UTG-CCGV sold separately. Must order one with each Compact Cassette. 2 Cassette Grille UTG-LCGV sold separately. Must order one with each Cassette. VRF 216,000 BTU (18 Tons) 63.3kW (24HP) 240,000 BTU (20 Tons) 70.3kW (26HP) 264,000 BTU (22 Tons) 77.3kW (28HP) AOUA216RLBVG AOUA240RLBVG AOUA264RLBVG AOUA288RLBVG UNIT : AOUA72RLBV UNIT : AOUA72RLBV UNIT : AOUA72RLBV UNIT : AOUA72RLBV UNIT : AOUA72RLBV UNIT : AOUA96RLBV UNIT : AOUA72RLBV UNIT : AOUA96RLBV UNIT : AOUA96RLBV UNIT : AOUA96RLBV UNIT : AOUA96RLBV UNIT : AOUA96RLBV 18,000 24,000 30,000 36,000 AUUA18RLAV AUUA24RLAV AUUB18RLAV AUUB24RLAV AUUB30RLAV AUUB36RLAV ARUM24RLAV ARUM30RLAV ARUM36RLAV 288,000 (24 Tons) 84.3kW (30HP) 48,000 60,000 ARUH48RLAV ARUH60RLAV ARUL18RLAV ARUH36RLAV ABUA18RLAV ABUA24RLAV ABUA30RLAV ASUB18RLAV ABUA36RLAV ASUB24RLAV 11 Various Energy Saving Features Energy saving technology increases efficiency Powerful large propeller fan: High performance, low noise Computational Fluid Dynamics designed fan. DC Fan motor: Power consumption has been reduced by using a compact and high performance DC fan motor. 4-face heat exchanger: Heat exchange efficiency is significantly improved by the use of a 4-face heat exchanger that increases effective surface area. Sine-wave DC inverter control: High efficiency operation is achieved by using a sine wave DC inverter control. Subcooled heat exchanger: High heat exchange efficiency is achieved by using an internal projection shape double pipe construction. DC twin rotary compressor: High efficiency is achieved by using a large capacity DC twin rotary compressor, improving refrigerant intake and compression efficiency. In multiple outdoor unit installations, the unique front intake design improves airflow into the Heat Exchanger. Room temperature set point limitation Peak cut operation The minimum and maximum temperature range can be set providing energy savings while considering the comfort of the occupants. To reduce peak demand charges, this function sets a maximum value (maximum average power) for the entire air conditioning system during specified peak periods. Consumption is monitored using a field-installed power meter. During a Peak Cut condition, the heating or cooling delivered to each indoor unit will be adjusted by: shifting indoor set temperature, applying a forced off function to specified units, or by stopping the entire system. °F 86.0 82.0 79.0 75.0 72.0 68.0 64.0 61.0 57.0 54.0 50.0 °C 30.0 28.0 26.0 24.0 22.0 20.0 18.0 16.0 14.0 12.0 10.0 Peak cut Capacity Control device Setting level Heating Cooling Heating set Cooling set temp. range temp. range Original Set temp. limitation Set point limitation setting W Operation setting (System Controller) Time Signal input Off timer Each remote controller is equipped with an OFF timer function that automatically stops operation when a fixed time has elapsed from the start of operation. This prevents wasting energy. (Note: Except simple remote controller) Set Temp. Down Heating Set Temperature Down MAX. -8°F/-4°C Down Down Economy operation Control Temperature Economy operation Economy operation Economy operation can be set by remote controller. The temperature setting is offset automatically over a certain period of time. 12 Set Temp. Economy operation Control Temperature MAX. +4°F/+2°C Cooling Set Temperature Economy operation Up Up VRF A Front side knockout position Outdoor Units ø 1.7 (43.7) 27.2 (690) (Bolt pitch) 3.1 (80) 20.9 (530) (Bolt pitch) 6, 8 Tons (8, 10HP) AOUA72RLBV AOUA96RLBV Power supply cable port 2.9 (73) 2.1 (53) 8-12×17 (Hole) ø 0.9 (22.2) Transmission cable port Dimensions Unit : in (mm) 36.6 (930) 0.4 (10) 3.0 (75) 3.9 (100) 28.8 (732) (Bolt pitch) 3.7 (95) ø 0.9 (22.2) Transmission cable port Pipe port 4.9 (125) 7.0 (179) B Left side knockout position 30.1 (765) ø2.4 (61.3) Power supply cable port ø1.7 (43.7) Power supply cable port ø0.9 (22.2) 66.5 (1690) Transmission cable port 25.7 (652.5) C Bottom side knockout position A 3.1 (80) Pipe port Back view C 3.2 (82) B Top view 1.7 (42) 7.5 (190) Specifications Capacity Range Tons (HP) 6 (8) 8 (10) 12 (16) 14 (18) 16 (20) 18 (24) 20 (26) 22 (28) 24 (30) AHRI Ref. No. - Non-Ducted AHRI Ref. No. - Ducted 5198211 5198214 5198217 5198220 5198223 5198226 5198229 5198232 5198235 5198212 5198215 5198218 5198221 5198224 5198227 5198230 5198233 5198236 AHRI Ref. No. - Mixed 5198213 5198216 5198219 5198222 5198225 5198228 5198231 5198234 5198237 Model Number AOUA72RLBV AOUA96RLBV AOUA144RLBV AOUA168RLBV AOUA192RLBV AOUA216RLBV AOUA240RLBV AOUA264RLBV AOUA288RLBV Outdoor Units AOUA72RLBV AOUA96RLBV AOUA72RLBV AOUA72RLBV AOUA96RLBV AOUA72RLBV AOUA96RLBV AOUA96RLBV AOUA72RLBV AOUA72RLBV AOUA72RLBV AOUA72RLBV AOUA72RLBV AOUA96RLBV AOUA72RLBV AOUA96RLBV AOUA96RLBV AOUA96RLBV AOUA96RLBV AOUA96RLBV 92 12.5 / 12.3 / 12.4 21.7 / 18.2 / 19.9 High Heating 47°F Capacity (kBtuh) EER IEER Capacity (kBtuh) 77 103 (Non-Ducted/Ducted/Mixed) COP 3.76 / 3.64 / 3.70 3.55 / 3.47 / 3.51 Low Heating 17°F Capacity (kBtuh) (Non-Ducted/Ducted/Mixed) COP Cooling (Non-Ducted/Ducted/Mixed) 69 138 160 56 73 2.30 / 2.30 / 2.30 2.50 / 2.40 / 2.45 154 180 118 24 Power Source 274 9.6 / 10.0 / 9.8 18.0 / 15.3 / 16.6 230 258 282 308 3.53 / 3.58 / 3.56 3.21 / 3.21 / 3.21 3.21 / 3.21 / 3.21 160 166 191 200 2.38 / 2.27 / 2.33 2.24 / 2.20 / 2.22 2.31 / 2.20 / 2.26 2.37 / 2.20 / 2.29 29 31 35 42 45 21 x 3 32 3-phase 3 wires, 208-230V, 60Hz MCA (A) Recommended Breaker Size (A) RLA kBtuh Cooling kW Capacity kBtuh Heating kW Height in./ mm. Width Depth Pre-charge Refrigerant Operation Range 252 10.3 / 10.9 / 10.6 19.0 / 16.4 / 17.7 50% to 130% 16 12 Connectable Indoor Units Connection Pipe Diameter 228 11.3 / 11.9 / 11.6 19.6 / 17.2 / 18.4 3.72 / 3.60 / 3.66 128 2.36 / 2.19 / 2.28 2.47 / 2.22 / 2.35 2.53 / 2.30 / 2.42 Indoor Unit Connectable Capacity Dimensions 12.0 / 12.0 / 12.0 20.2 / 17.2 / 18.7 196 3.68 / 3.46 / 3.57 3.60 / 3.54 / 3.57 3.55 / 3.44 / 3.50 107 206 175 11.7 / 11.6 / 11.6 12.4 / 11.0 / 11.7 11.6 / 11.2 / 11.4 11.4 / 11.1 / 11.2 20.8 / 17.8 / 19.3 19.5 / 14.6 / 17.0 19.5 / 17.1 / 18.3 19.6 / 17.3 / 18.4 41 x 2 45 45 x 2 Gas Cooling Heating °F / °C 45 x 3 21 14 x 2 14 + 21 21 + 21 14 x 3 14 +14 + 21 14 +21 + 21 72 96 144 168 192 216 240 264 288 21.1 28.1 42.2 49.2 56.2 63.3 70.3 77.3 84.3 80 108 162 188 216 243 270 296 324 23.4 31.6 47.4 55.1 63.3 71.2 79.1 86.7 94.9 66.5 / 1,690 66.5 / 1,690 66.5 / 1,690 36.6 / 930 36.6 x 2 / 930 x 2 36.6 x 3 / 930 x 3 30.1 / 765 in./ mm. 41 x 3 14 24.69 / 11.20 lb / kg Liquid 41 30.1 / 765 1/2 / 12.70 7/8 / 22.22 5 ~ 115 / -15 ~ 46 30.1 / 765 24.69 + 24.69 / 11.20 +11.20 24.69 + 24.69 + 24.69 / 11.20 + 11.20 + 11.20 3/4 / 19.05 5/8 / 15.88 1-1/8 / 28.58 1-3/8 / 34.92 23 ~ 115 / -5 ~ 46 -4 ~ 70 / -20 ~ 21 Note: Specifications are based on the following conditions: Cooling: Indoor temperature of 80.6°F / 27°C and outdoor temperature of 95°F / 35°C. Heating: Indoor temperature of 68°F / 20°C and outdoor temperature of 45°F / 7°C. Pipe length: 24.6 ft. / 7.5 m., Height difference between outdoor unit and indoor unit: 0 ft. / 0 m. Our outdoor units shall withstand 1,000 hours of salt spray tested per procedure ASTM B117. 13 Compact Cassette Models AUUA7RLAV AUUA9RLAV AUUA12RLAV AUUA14RLAV AUUA18RLAV AUUA24RLAV Compact size panel design that fits a standard ceiling panel 23-5/8 x 23-5/8in (600x600mm) 2-stage turbo fan Quiet quality High efficiency design by 2 stage structure Optimization of wing form (laminar wing type) and wing number (7 blades each) Evenly spread air distribution across the heat exchanger is possible due to the new 2 stage turbo fan which produces two separate airflow streams. Designed using Computational Fluid Dynamics (CFD) simulations. Adoption of laminar wing Quiet + 2-stage Airflow runs smoothly along the laminar wing 2-stage turbo fan 1-stage Laminar wing Heat exchange efficiency = Wind velocity Fast 20%UP Quiet Slow Spin direction No airflow separation Airflow direction Specifications Model name AUUA18RLAV AUUA24RLAV 14,000 18,000 24,000 4.1 5.3 7.0 13,500 15,600 20,000 27,000 3.2 4.0 4.6 5.9 7.9 25 29 35 36 84 324 (550) 353 (600) 400 (680) 418 (710) 606 (1,030) AUUA7RLAV AUUA9RLAV Btu/h 7,500 9,500 12,000 kW 2.2 2.8 3.5 Btu/h 9,500 10,900 kW 2.8 W 25 CFM (m³ / h) 318 (540) Power source Cooling Heating Input power Airflow rate High Med Sound pressure level 265 (450) 265 (450) 312 (530) 347 (590) 341 (580) 489 (830) Low 206 (350) 206 (350) 230 (390) 230 (390) 235 (400) 265 (450) High 34 35 37 38 41 50 30 30 34 34 35 44 25 25 27 27 27 30 Med dB(A) Low in.(mm) Dimensions (H x W x D) lbs.(kg) Weight Connection pipe diameter Liquid (Flare) Gas (Flare) in.(mm) 9-21/32 × 22-7/16 × 22-7/16 (245 × 570 × 570) 33 (15) 38 (17) ø 1/4 (6.35) ø 3/8 (9.52) ø 1/2 (2.70) ø 5/8 (15.88) Drain ø 3/4 (25) (I.D) ; ø 1-1/16 (32) (O.D.) Dimensions (H x W x D) in.(mm) 1-31/32 × 27-9/16 × 27-9/16 (50 × 700 × 700) UTG-CCGV Model name Weight 14 AUUA14RLAV Single phase, 208-230V , 60Hz Capacity Grille(option) AUUA12RLAV lbs.(kg) 6 (2.6) Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 80°F(26.7°C)DB/67°F(19.4°C)WB,and outdoor temperature of 95.0°F(35°C)DB/75°F(23.9°C)WB. Heating : Indoor temperature of 70°F(21.1°C)DB/60°F(15.6°C)WB,and outdoor temperature of 47°F(8.3°C)DB/43°F(6.1°C)WB. Pipe length : 25ft.(7.5 m), Height difference : 0ft.(0 m) (Outdoor unit - Indoor unit). Built-in protective functions may limit capacity or shut off unit if unit is operated outside of unit design operating temperature ranges. VRF Improvement of airflow distribution Condensate Drain Pump (Standard) Max Lift Ceiling panel 27-9/16in (700mm) 1 A B C D 3 High ceiling mode 2 1 Grille cover The compact cassette can be installed up to a height of 9’ 10-1/8” (3.0m) (AUUA12/14/18/24). Easy maintenance of fan and motor The maximum height from floor to ceiling ft.(m) Access and maintenance of the fan and motor can be accomplished by removing the panel. The fan and motor can be easily removed. A : Fan motor C : Bell-mouth Model code 7 9 12 14 18 24 B : 2-stage turbo fan D : Panel 2 Long life filter : standard equipment 3 Adaptation of transparent drainage parts Standard mode High ceiling mode 8’ 10-5/16” (2.7) 8’ 10-5/16” (2.7) 8’ 10-5/16” (2.7) 8’ 10-5/16” (2.7) 8’ 10-5/16” (2.7) 8’ 10-5/16” (2.7) - 9’ 10-1/8” (3.0) 9’ 10-1/8” (3.0) 9’ 10-1/8” (3.0) 9’ 10-1/8” (3.0) During installation, maintenance and operation, the drain pump and kit can be checked easily. Optional parts 22-7/16in 570mm Compact design 22-7/16in 570mm Air Outlet Shutter Plate : UTR-YDZB Insulation Kit for High Humidity : UTZ-KXGC Fresh Air Intake Kit : UTZ-VXAA Worlds first 24,000Btu model in the compact cassette category (Easy installation by taking off ceiling panel of 23-5/8 x 23-5/8in (600 x 600mm) Dimensions IR Receiver is standard for communicating with Optional Wireless Controller. Unit: In (mm) Models: AUUA7 / AUUA9 / AUUA12 / AUUA14 / AUUA18 / AUUA24 20-7/8(530) View A 11-7/32(285) 21-1/4(540) Hanging bolt position 14-9/16(370) œ22-7/16(570): Indoor unit 27-9/16(700) IR reciever œ22-27/32 to 26(580 to 660) Ceiling openings 20-7/8(530) Hanging bolt position 27-9/16(700) A View B Drain hose 5-13/16(146) 11-7/32(285) 7-7/32(183) 1-3/16(30) 10-5/16(262) Gas pipe Liquid pipe 4-27/32(123) Control Box 1-3/16(30) 3/4(19) Ceiling 4-1/2(114) 4-1/2(114) 8-15/32(215) B 1-9/16(40) 15 Cassette Models AUUB18RLAV AUUB24RLAV AUUB30RLAV AUUB36RLAV Powerful, wide airflow and quiet operation High efficiency turbo fan with 3-dimensional blade Quiet quality Optimization of wing form (laminar wing type) and wing number (7 blades each) High efficiency airflow distribution has been achieved by the introduction of a 3 dimensional blade which increases the air passing over the heat exchanger. Designed using Computational Fluid Dynamics (CFD) simulations Adoption of laminar wing Quiet 19-11/16in (500mm) Laminar wing Airflow runs smoothly along the laminar wing 3-dimensional blade Heat exchanger < Motor side > Wind velocity Fast Quiet Quiet Spin direction No airflow separation Slow No airflow separation Airflow direction : Airflow direction : Spin direction Specifications AUUB18RLAV Model name AUUB24RLAV Power source Capacity Cooling Heating Input power Airflow rate High Med Sound pressure level Btu/h 18,000 24,000 30,000 kW 5.3 7.0 8.8 10.6 Btu/h 20,000 27,000 34,000 40,000 kW 5.9 7.9 10.0 11.7 W 39 46 59 80 CFM (m³ / h) 677 (1,150) 753 (1,280) 942 (1,600) 1,059 (1,800) 612 (1,040) 765 (1,300) 765 (1,300) 512 (870) 512 (870) 647 (1,100) 647 (1,100) High 36 38 40 44 30 33 38 38 29 29 33 33 Dimensions (H x W x D) Weight Connection pipe diameter dB(A) in.(mm) 9-11/16 × 33-1/16 × 33-1/16 (246 × 840 × 840) lbs.(kg) 51 (23) Gas (Flare) 11-11/32 × 33-1/16 × 33-1/16 (288 × 840 × 840) 60 (27) Liquid (Flare) ø 3/8 (9.52) in.(mm) ø 5/8 (15.88) ø 3/4 (19.05) Drain ø 3/4 [I.D.] ; ø 1-1/16 [O.D.] Dimensions (H x W x D) in.(mm) 1-31/32 × 37-13/32 × 37-13/32 (50 × 950 × 950) Model name Weight 36,000 553 (940) Low 16 AUUB36RLAV Low Med Grille(option) AUUB30RLAV Single phase, 208-230V , 60Hz UTG-LCGV lbs.(kg) 13 (5.5) Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 80°F(26.7°C)DB/67°F(19.4°C)WB,and outdoor temperature of 95.0°F(35°C)DB/75°F(23.9°C)WB. Heating : Indoor temperature of 70°F(21.1°C)DB/60°F(15.6°C)WB,and outdoor temperature of 47°F(8.3°C)DB/43°F(6.1°C)WB. Pipe length : 25ft.(7.5 m), Height difference : 0ft.(0 m) (Outdoor unit - Indoor unit). Built-in protective functions may limit capacity or shut off unit if unit is operated outside of unit design operating temperature ranges. VRF Improvement of the airflow distribution Condensate Drain Pump (Standard) The louver design distributes air leaving a space between the chassis and the ceiling allowing far and wide air flow distribution. Front part Max Lift Ceiling panel Ceiling 33-1/2in (850mm) Bottom view Rear part Wide airflow discharge reduces temperature irregularity Round louver High ceiling mode This cassette can be installed up to a height of 13’9”. (4.2m) (AUUA36). Hanger position can be adjusted after installation The maximum height from floor to ceiling ft. (m) Model code 18 24 30 36 Detachable Grille corner Standard mode High ceiling mode 9’ 10-1/8” (3.0) 9’ 10-1/8” (3.0) 10’ 6” (3.2) 10’ 6” (3.2) 11’ 6” (3.5) 11’ 6” (3.5) 11’ 9-3/4” (3.6) 13’ 9-3/8” (4.2) Adjustment can be done by taking off the corner part Optional parts IR Receiver Kit : Air Outlet Shutter Plate : Panel Spacer : UTZ-KXGA / UTZ-KXGB UTG-AGYA-W UTZ-VXGA Insulation Kit for High Humidity : Wide Panel : Fresh Air Intake Kit : Unit: In (mm) 37-13/32(950) 9-27/32(250) A 14-3/32(358) 14-3/32(358) 7-9/32(185) 1-7/32(31) 1-7/32(31) Fresh air inlet (cut out) 2-3/4(70) Drain hose View A 33-27/32 to 35-13/16(860 to 910) Ceiling opening 23-29/32(607) 37-13/32(950) œSS‰@@\’QU?“M%    31-11-32(796) Hanging bolt position 27-17/32(699) Hanging bolt position IR reciver (Option) 16-17/32(420) Dimensions UTY-LRHYB1 UTR-YDZC UTG-BGYA-W View B 10-15/16(278) 2-3/8(60) 1-9/16(40) C Gas pipe Wire hole 5-1/2(140) Liquid pipe 1-23/32(44) 13/32(10) Ceiling 5-19/32(142) 5-19/32(142) 7-7/8(200) B Model AUUB18/24 AUUB30/36 C 10-3/32(256) 11-23/32(298) 17 Slim Compact Duct Models (Drain pump internal model) ARUL7RLAV ARUL9RLAV ARUL12RLAV ARUL14RLAV ARUL18RLAV ARUL7RLAV ARUL9RLAV ARUL12RLAV ARUL14RLAV ARUL18RLAV Slim design and wide range of static pressure for flexible installation. Slim design Flexible installation This model has a slim design so it can be installed in narrow ceilings. Slim Compact Duct units can be mounted horizontally or vertically and can deliver up to 0.36” external static pressure providing the power and flexibility to meet the needs of most applications. Drain port Ceiling concealed Height 7-25/32in (198mm) Drain pump built-in Floor concealed Drain pump Specifications ARUL9RLAV ARUL7RLAV Model name ARUL12RLAV Power source Capacity Cooling Heating Input power Airflow rate High Med Static pressure range 9,500 12,000 14,000 2.2 2.8 3.5 4.1 5.3 Btu/h 9,500 10,900 13,500 15,600 20,000 kW 2.8 3.2 4.0 4.6 5.9 W 44 50 54 92 83 324 (550) 353 (600) 353 (600) 471 (800) 553 (940) 288 (490) 324 (550) 300 (510) 418 (710) 494 (840) 258 (440) 283 (480) 265 (450) 359 (610) 441 (750) 0 to 0.36 (0 to 90) 0 to 0.36 (0 to 90) 0 to 0.36 (0 to 90) 0 to 0.36 (0 to 90) 0 to 0.36 (0 to 90) 0.10 (25) 0.10 (25) 0.10 (25) 0.10 (25) 0.10 (25) 28 29 30 34 34 25 26 27 32 32 22 24 24 28 CFM m3/ h High Med dB(A) Low Dimensions (H x W x D) in.(mm) Weight lbs.(kg) Liquid (Flare) Gas (Flare) Drain 18 18,000 7,500 kW in.WG (Pa) Standard static pressure Connection pipe diameter ARUL18RLAV Btu/h Low Sound pressure level ARUL14RLAV Single phase, 208-230V , 60Hz in.(mm) 7-25/32 × 27-9/16 × 24-13/32 (198 × 700 × 620) 40 (18) 42 (19) 28 7-25/32 × 35-7/16 × 24-13/32 (198 × 900 × 620) 51 (23) ø 1/4 (6.35) ø 3/8 (9.52) ø 1/2 (12.70) ø 5/8 (15.88) ø 3/4 [I.D.] ; ø 1-1/16 [O.D.] Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 80°F(26.7°C)DB/67°F(19.4°C)WB,and outdoor temperature of 95.0°F(35°C)DB/75°F(23.9°C)WB. Heating : Indoor temperature of 70°F(21.1°C)DB/60°F(15.6°C)WB,and outdoor temperature of 47°F(8.3°C)DB/43°F(6.1°C)WB. Pipe length : 25ft.(7.5 m), Height difference : 0ft.(0 m) (Outdoor unit - Indoor unit). Built-in protective functions may limit capacity or shut off unit if unit is operated outside of unit design operating temperature ranges. VRF Auto Louver Grille Kit (Option) Condensate Drain Pump (Standard) Simple flat Auto Louver will provide comfortable airflow and blend with any interior. Max Lift 33-1/2in (850mm) Slim Duct Auto Louver Grille Opened louver Drain hose is a standard accessory Closed louver Selectable External Static Pressure The external static pressure can be selected for any value from 0 to 0.36 in.WG. (0 to 90 Pa). Static pressure setting can be changed using the remote controller. Wired Remote Controller Wireles Remote Controller Operation with indoor unit UP and Down auto swing Auto-closing louver Static pressure range See Page 49 for more details. Filter (Accessory) 0.36 in.WG (0 to 90 Pa) ARUL7 / 9 / 12 / 14 / 18 Filter (2pcs.) Air-intake Air intake direction can be selected to match the installation site. Optional parts Bottom side Remote Sensor Unit : UTD-RS100 IR Receiver Unit : UTB-YWC Auto Louver Grille Kit : UTD-GXSA-W (for ARUL7/9/12/14RLAV) UTD-GXSB-W (for ARUL18RLAV) Back side In locations where fan noise may be a concern, do not use bottom inlet without providing an elbow to prevent line of sight to the fan. Dimensions Unit: In (mm) 1-3/16 (30) M V 2 (51) 22-19/32 (574) 2-25/32 (71) 6 (152) 6-27/32 (174) 14-27/32 (377) Models: ARUL7 / ARUL9 / ARUL12 / ARUL14 / ARUL18 Rear view U 25-19/32 T(650) 28-29/32 S(734) N O P Q R S T U V Liquid Refrigerant pipe flare connection Gas Drain hose connection - Drain Hose ARUL7, ARUL9, ARUL12, ARUL14 ø 1/4 (6.35) ø 3/8 (9.52) ø 1/2 (12.70) ø 5/8 (15.88) ARUL18 I.D. 31/32 (25), O.D. 1-1/4 (32) 27-9/16 (700) 35-7/16 (900) - 26-5/32 (664) 34-1/32 (864) - 25-19/32 (650) 33-15/32 (850) - 28-29/32 (734) 36-25/32 (934) 25-19/32 (650) 33-15/32 (850) 3-15/16 (100) x 6 = 23-5/8 (600) 22-19/32 (574) 3-15/16 (100) x 8 = 31-1/2 (800) 30-15/32 (774) 3-15/16 (100) x 6 = 23-5/8 (600) (Drain hose) 1-7/8 (48) 1-7/32 (31) R 26-5/32 Q (664) 27-9/16 P (700) 25-19/32 (650) Front view 1-27/32 (47) 3-1/2 (89) 2-5/32 (55) 3-1/16 (78) 6-13/32 (163) 1-11/16 (43) 4-11/16 (119) 2-5/32 (55) 3-7/32 (82) 3-1/16 (78) 5-15/16 (151) 6-5/8 (168) 7-25/32 (198) Top view 13/32 (10) Drain port 2-23/32 (69) 5-21/32 (144) 10-13/32 (264) 14-7/16 (367) 24-13/32 (620) Side view 19 Duct Models ARUM24RLAV ARUM30RLAV ARUM36RLAV Slim Compact design allows for easy installation in narrow ceiling spaces up to 10-5/8in (270mm). Slim & Compact design Easy maintenance In the case of bottom return air connection, not only does the indoor unit design allow for installation in a narrow ceiling space of up to 10-5/8in (270mm), further space savings have been achieved by mounting the electrical control box internally inside the chassis. Structural improvement is attained by making the bottom panel two pieces, front and rear. The internal fan casing is also manufactured in two pieces, namely upper and lower. The maintenance of the motor and fan can be easily carried out by removing the rear panel and the lower part of the casing while leaving the main chassis 1 installed. 44-11/16in (1,135mm) Control box is now included as part of the main chassis 4 10-5/8in (270mm) 3 2 1.Control box 2.Fan casing 3.Fan 4.Motor Bottom panel: 2 pieces One touch operating and easy to install long life filter (Optional Parts) Specifications Model name ARUM24RLAV Power source Capacity Cooling Heating Input power Airflow rate High Med Static pressure range 24,000 30,000 kW 7.0 8.8 10.6 Btu/h 27,000 34,000 40,000 kW 7.9 10.0 11.7 W 200 200 320 CFM (m³ / h) 706 (1,200) 706 (1,200) 1,012 (1,720) in.WG (Pa) Standard static pressure High Med dB(A) Low Dimensions (H x W x D) in.(mm) Weight lbs.(kg) Connection pipe diameter Gas (Flare) 36,000 647 (1,100) 647 (1,100) 983 (1,670) 589 (1,000) 589 (1,000) 942 (1,600) 0.12 to 0.60 (30 to 150) 0.12 to 0.60 (30 to 150) 0.12 to 0.60 (30 to 150) 0.40 (100) 0.40 (100) 0.40 (100) 40 40 43 38 38 41 36 36 39 10-5/16 × 44-11/16 × 27-9/16 (270 × 1,135 × 700) 93 (42) 95 (43) Liquid (Flare) Drain 20 ARUM36RLAV Btu/h Low Sound pressure level ARUM30RLAV Single phase, 208-230V , 60Hz ø 3/8 (9.52) in.(mm) ø 3/4 (19.05) ø 5/8 (15.88) ø 3/4 [I.D.] ; ø 1-1/16 [O.D.] Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 80°F(26.7°C)DB/67°F(19.4°C)WB,and outdoor temperature of 95.0°F(35°C)DB/75°F(23.9°C)WB. Heating : Indoor temperature of 70°F(21.1°C)DB/60°F(15.6°C)WB,and outdoor temperature of 47°F(8.3°C)DB/43°F(6.1°C)WB. Pipe length : 25ft.(7.5 m), Height difference : 0ft.(0 m) (Outdoor unit - Indoor unit). Built-in protective functions may limit capacity or shut off unit if unit is operated outside of unit design operating temperature ranges. VRF Two-direction drain piping Installation styles Embedded in Ceiling Hanging from Ceiling Duct indoor unit Two-direction drain piping Air-intake Air intake direction can be selected to match the installation site. Optional parts Bottom side Remote Sensor Unit : UTD-RS100 Long Life Filter* : UTD-LF25NA Flange (Square) : UTD-SF045T Back side In locations where fan noise may be a concern, do not use bottom inlet without providing an elbow to prevent line of sight to the fan. Dimensions Flange (Round) : UTD-RF204 IR Receiver Unit : UTB-YWC Drain Pump Unit : UTZ-PX1NBA *Note, Duct models do not include a standard filter. Unit: In (mm) 5-7/16 (138) 10-13/32 (264) 10-13/32 (264) 10-13/32 (264) 3-5/32 (80) 3-5/32 (80) Models: ARUM24 / ARUM30 / ARUM36 1-17/32 (39) 4-Ø1/8 (3.2) (hole) 3-5/32 (80) 4-3/4 (121) M N O P Q Refrigerant pipe flare connection Drain hose connection - ARUM36 Liquid ø 3/8 (9.52) ø 3/8 (9.52) Gas ø 5/8 (15.88) ø 3/4 (19.05) Drain Hose 4-23/32 P4-29/32 (125) x 3 = 14-3/4 (375) (120) 39-31/32 (1015) 3-5/32 (80) Side view (L) 2-7/8 (73) 2-7/32 (107) 11-5/32 (283) 9-7/16 (240) 6-5/8 (168) 8-Ø3/16 (5) (hole) P4-29/32 (125) x 3 = 14-3/4 (375) 27/32 (21.8) 27/32 (21.8) 6-11/32 (173) 6-11/32 (161) 3-5/32 (80) 3-5/32 (80) Bolt pitch 18-25/32 (477) Ø7-7/8 (200) (knock out hole) 11-1/16 (281) 1-1/4 (32) P.C.D. Ø8-27/32 (225) ARUM24, ARUM30 2-19/32 (66) Outlet 1-1/4 (32) Drain port 4-1/2 (114) Bolt pitch 46-11/32 (1177) 10-5/8 (270) 2-1/8 (54) Rear view 2-15/16 (75) P.C.D. Ø8-27/32 (225) Front view 9-7/16 (240) Drain port Ø8-1/16 (205) (hole) 4-Ø1/8 (3.2) (hole) 1-9/16 (40) (Drain hose) 3-5/32 (80) 5-7/16 (138) 3-5/32 (80) 3-7/32 (82) 2-Ø3/16 (5) (hole) 6-11/16 (170) 9-7/16 (240) 1-11/32 (34) 5/8 (16) 10-5/8 (270) 44-11/16 (1135) Top view Side view (R) I.D. 31/32 (25) , O.D. 1-1/4 (32) 7-7/8 (200) 29/32 (23) 21 High Static Pressure Duct Models ARUH36RLAV ARUH48RLAV ARUH60RLAV High Static Pressure Ducted Units combine efficient casing design with non metallic fan wheels and casings to reduce noise levels; units are capable of delivering hot or cold air at static pressures up to 1 in.WG. These units are perfect for conditioning hard-to-reach areas and are able to meet the needs of many different types of applications. Easy installation (Compact size & Lightweight) 32-11/16in (500mm) 41-11/32in (1,050mm) A compact and lightweight chassis has been developed to simplify installation and provide better flexibility for tight installation spaces. 15-3/4in (400mm) 99lb (45kg) Specifications ARUH36RLAV Model name Power source Capacity Cooling Heating Input power Airflow rate 36,000 48,000 kW 10.6 14.1 17.6 Btu/h 40,000 54,000 67,000 kW 11.7 15.8 19.6 W 530 750 810 1,324 (2,250) 1,766 (3,000) 1,972 (3,350) 1,030 (1,750) 1,589 (2,700) 1,678 (2,850) 824 (1,400) 1,354 (2,300) CFM m 3/ h Low Static pressure range in.WG (PA) Standard static pressure High Med dB(A) Low lbs.(kg) Weight Liquid (Flare) Gas (Flare) Drain 22 0.40 to 0.80 (100 to 200) 60,000 1,501 (2,550) 0.40 to 1.00 (100 to 250) 0.40 (100) 43 47 48 37 43 44 32 40 41 in.(mm) Dimensions (H x W x D) Connection pipe diameter ARUH60RLAV Btu/h High Med Sound pressure level ARUH48RLAV Single phase, 208-230V , 60Hz 15-3/4 × 41-11/32 × 19-11/16 (400 × 1,050 × 500) 95 (43) 99 (45) ø 3/8 (9.52) in.(mm) ø 3/4 (19.05) ø 3/4 [I.D.] ; ø 1-1/16 [O.D.] Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 80°F(26.7°C)DB/67°F(19.4°C)WB,and outdoor temperature of 95.0°F(35°C)DB/75°F(23.9°C)WB. Heating : Indoor temperature of 70°F(21.1°C)DB/60°F(15.6°C)WB,and outdoor temperature of 47°F(8.3°C)DB/43°F(6.1°C)WB. Pipe length : 25ft.(7.5 m), Height difference : 0ft.(0 m) (Outdoor unit - Indoor unit). Built-in protective functions may limit capacity or shut off unit if unit is operated outside of unit design operating temperature ranges. VRF High static pressure design Low noise Indoor unit Up To Efficient chassis design has enabled less turbulent air flow. Non-metallic fan wheel and casing reduces fan noise. 1 in.WG (250Pa) Non-metallic fan Heat 8-27/32in exchanger ø225mm (ARUH48/60 ) Casing (Non-metallic) Med. noise level 43dB(A) (ARUH48) Optional parts Long-Life Filter* : UTD-LF60KA IR Receiver Unit : UTB-YWC Remote Sensor Unit: UTD-RS100 *Note, High Static Pressure Duct models do not include a standard filter. Dimensions Unit: In (mm) 3-15/32 (88) Models: ARUH34 / ARUH48 / ARUH54 9/16 (14) 23-1/32 (585) 19-11/16 (500) Drain port (Drain hose) 5-15/32 (139) Front view 14-19/32 (371) 14-1/32 (356) 8-3/16 (208) 4-1/4 (108) 42-17/32 (1080) 39-3/8 (1000) 33-15/16 (862) 1-5/8 (41) 15-3/4 (400) 12-3/4 (324) 6-3/32 (155) 4-27/32 (123) 2-25/32 (71) Rear view 12-Ø1/8 (3) P4-23/32 (120) x 2 = 9-7/16 (240) 11-5/8 (295) 1-3/32 (28) 1-1/32 (26) 4-31/32 (126) P4-23/32 (120) x 5 = 23-5/8 (600) 33-1/2 (851) ARUH36, ARUH48, ARUH60 M N O Refrigerant pipe flare connection Liquid Drain hose connection Drain Hose Gas ø 3/8 (9.52) Side view (L) 41-11/32 (1050) Side view (R) 4-29/32 (125) 3-11/32 (85) Top view ø 3/4 (19.05) I.D. 31/32 (25) , O.D. 1-1/4 (32) 23 Floor / Ceiling Models ABUA12RLAV ABUA14RLAV ABUA18RLAV ABUA24RLAV The slim and lightweight design allows the unit to be suspended from the ceiling or installed on the floor. This type suits many room designs. Flexible installation Example of floor installation Example of ceiling installation Floor console Under ceiling Specifications ABUA12RLAV Model name ABUA14RLAV Power source Capacity Cooling Heating Input power Airflow rate 12,000 14,000 18,000 kW 3.5 4.1 5.3 7.0 Btu/h 13,500 15,600 20,000 27,000 kW 4.0 4.6 5.9 7.9 W 30 42 74 99 388 (660) 459 (780) 589 (1,000) 589 (1,000) CFM (m³ / h) 336 (570) 377 (640) 424 (720) 483 (820) 288 (490) 324 (550) 341 (580) 400 (680) High 36 40 46 47 32 36 39 42 28 34 35 37 dB(A) Low Dimensions (H x W x D) 7-27/32 × 38-31/32 × 25-25/32 (199 × 990 × 655) in.(mm) lbs.(kg) Weight Liquid (Flare) Gas (Flare) Drain 24 24,000 Low Med Connection pipe diameter ABUA24RLAV Btu/h High Med Sound pressure level ABUA18RLAV Single phase, 208-230V , 60Hz in.(mm) 60 (27) 56 (25) ø 1/4 (6.35) ø 3/8 (9.52) ø 1/2 (12.70) ø 5/8 (15.88) ø 3/4 [I.D.] ; ø 1-1/16 [O.D.] Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 80°F(26.7°C)DB/67°F(19.4°C)WB,and outdoor temperature of 95.0°F(35°C)DB/75°F(23.9°C)WB. Heating : Indoor temperature of 70°F(21.1°C)DB/60°F(15.6°C)WB,and outdoor temperature of 47°F(8.3°C)DB/43°F(6.1°C)WB. Pipe length : 25ft.(7.5 m), Height difference : 0ft.(0 m) (Outdoor unit - Indoor unit). Built-in protective functions may limit capacity or shut off unit if unit is operated outside of unit design operating temperature ranges. VRF Double auto swing Super vane A combination of up/down and right/left directional swing allows three-dimensional air direction control. Double Louver Super vane with newly developed special configuration boosts airflow, quickly sending cool air to every corner of the room. RIGHT and LEFT SWING UP and DOWN SWING Auto-closing louver 3 2 1 4 1 5 When operation is stopped, the louvers will automatically close. (This function is available on all non-ducted models.) 2 3 4 Compact design 5 steps selectable Symmetrical, slim and compact design. 4 steps selectable Unit : in (mm) High power DC fan motor 25-25/32 (655) Ž  Œ    Ž  ; 39 (990) 7-27/32 (199) Note: IR Receiver is standard for communicating with Optional Wireless Controller. Unit: In (mm) 35-7/16 (900) 19-11/16 (500) (Drain hose) 7-7/8 (200) 20-7/8 (530) 7 1 3-15/32 (100) 1-3/32 (28) 6-7/8 (175) 3-15/32 5 (100) 1-27/32 (47) 4 7-27/32 (199) 1-1/16 (27) ø 5/8 (15.88) I.D. 31/32 (25), O.D. 1-1/4 (32) Drain Outlet ø 1-25/32 (45) - Use M10 screw bolt 2 2-5/8 (67) 2-15/32 (63) ø 1/2 (12.70) Drain Hose 1-13/16 (46) 2-27/32 (72) 3-27/32 (98) Knock out hole Hole for lifting bolt Gas 3-5/32 (80) Drain hose connection Liquid ø 3/8 (9.52) 6-3/8 (162) Refrigerant pipe flare connection ABUA18, ABUA24 ø 1/4 (6.35) 3-15/32 (100) 2-9/32 (58) 1 5 3-15/32 (100) M N O P QR S ABUA12, ABUA14 1-21/32 (42) 1-27/32 (72) 4-7/8 (124) 1-11/16 (43) 2 25/32 (20) 3-15/32 (100) 7-15/32 (190) 5-23/32 (145) 1/2 (13) 3-15/32 (100) 5 25-25/32 (655) Dimensions Models: ABUA12 / ABUA14 / ABUA18 / ABUA24 6 4-7/8 (124) 29-7/32 (742) 25 Ceiling Models ABUA30RLAV ABUA36RLAV Powerful ceiling-hung indoor units are easy to install and can provide plenty of warm or cold air to a large space. Ceiling-hung units are the perfect solution for large spaces such as classrooms, restaurants, and kitchens. Installation Open Concealed Wall mounted (Field Supplied) General installation pattern which suspends the indoor unit from the ceiling. Installation pattern where part of the indoor unit is embedded into the ceiling. Installation which fixes the indoor unit to the wall by the use of wall brackets (Field supplied). This type of installation can be used when the ceiling space is insufficient. Specifications Power source Capacity Single phase, 208-230V , 60Hz Cooling Heating Input power Airflow rate High Med Sound pressure level Btu/h 30,000 kW 8.8 10.6 Btu/h 34,000 40,000 kW 10.0 11.7 W 66 85 859 (1,630) 995 (1,690) CFM (m3/ h) 806 (1,370) 824 (1,400) 671 (1,140) 689 (1,170) High 42 45 38 38 dB(A) Low in.(mm) Weight lbs.(kg) Liquid (Flare) Gas (Flare) 34 33 Dimensions (H x W x D) Drain 26 36,000 Low Med Connection pipe diameter ABUA36RLAV ABUA30RLAV Model name in.(mm) 9-7/16 × 5ft. 5-11/32 × 27 -9/16 (240 × 1,660 × 700) 104 (47) 106 (48) ø 3/8 (9.52) ø 3/8 (9.52) ø 3/4 (19.05) ø 5/8 (15.88) ø 3/4 [I.D.] ; ø 1-1/16 [O.D.] Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 80°F(26.7°C)DB/67°F(19.4°C)WB,and outdoor temperature of 95.0°F(35°C)DB/75°F(23.9°C)WB. Heating : Indoor temperature of 70°F(21.1°C)DB/60°F(15.6°C)WB,and outdoor temperature of 47°F(8.3°C)DB/43°F(6.1°C)WB. Pipe length : 25ft.(7.5 m), Height difference : 0ft.(0 m) (Outdoor unit - Indoor unit). Built-in protective functions may limit capacity or shut off unit if unit is operated outside of unit design operating temperature ranges. VRF Double auto swing and wide airflow Condensate drain pump (Optional) Auto airflow direction and auto swing Optional drain lift-up mechanism allows flexible installation. Right and left Max Lift 19-11/16in (500mm) Fresh air intake 5 steps selectable Up and down Fresh air 1 Indoor 2 Outdoor 3 4 High power DC fan motor 4 steps selectable Ž  Œ    Ž  ; Quiet, powerful airflow Powerful airflow ensures comfort to every corner of a large room. Long-life filter High Efficiency long-life filter doubles the life of the filter compared to standard filters. -flow e air nc ista gd Lon Optional parts Slim & compact design Dimensions Drain Pump Unit : UTR-DPB24T Flange: UTD-RF204 Height 9-7/16in (240mm) Note: IR Receiver is standard for communicating with Optional Wireless Controller. Unit: In (mm) Models: ABUA30 / ABUA36 65-11/32 (1660) 63 (1600) 3 Drain hose connection Knock out hole Liquid Gas ø 3/4 (19.05) Drain Hose I.D. 31/32 (25), O.D. 1-1/4 (32) Drain Outlet Fresh Air ø 1-31/32 (50) Refrigerant Pipe Hole for lifting bolt ø 3/8 (9.52) ø 5/8 (15.88) - ø 7-7/8 (200) Use M10 screw bolt 5-1/8 (130) 6-1/2 (165) 6 3-7/32 5-5/16 (82) (135) 6-5/16 (160) 4-21/32 (118) 5 6-5/16 (160) 3-25/32 (96) 7-9/16 (192) Refrigerant pipe flare connection 6-5/16 (160) N O P Q R S 3-15/32 (88) 5-29/32 (150) M ABUA36 7-7/8 (200) 6-5/16 (160) 1-5/16 (33) 3-3/4 (95) 5-29/32 (150) ABUA30 1-3/16 (30) 9-7/16 (240) 2-9/16 (65) 5-13/32 (137) 4-17/32 3-15/16 (115) (100) 11-11/16 (300) 27-9/16 (700) 7 (Drain hose) 7-15/16 (202) 2 1 Drain port 4 Drain port 27 Compact Wall Mounted Models ASUA7RLAV ASUA9RLAV ASUA12RLAV ASUA14RLAV Compact and stylish design Filter features High performance filters provide high quality air conditioning Deodorizing effect (Odor reduction rate) Trimethylamine Ammonia Long-life*1 Ion Deodorization Filter (ppm) (ppm) 160 160 With no filter 120 The filter deodorizes by poerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic. With no filter 120 New filter 80 80 New filter 40 40 0 0 0 30 60 120 (min) 0 30 60 120 (min) Apple-catechin Filter* 2 Hydrogen sulfate Fine dust invisible mold spores and harmful microorganisms       ;   ;            ;  ;  extracted from apples. ”@&      ‡S;                 ; *2 Both filters can be mounted on the same unit. (ppm) 160 With no filter 120 80 New filter 40 0 0 30 60 120 (min) High performance filters have been thoroughly tested by the Environmental Sanitary Inspection Center using an advanced Deodorization Test. Specifications ASUA7RLAV Model name Capacity Cooling Heating %    +    High [Z?? >Z?? @X??? kW 2.2 2.8 SZ 4.1 Btu/h >Z?? @?>?? @SZ?? @Z\?? kW 2.8 3.2 4.0 4.6 W 16 16 19 30 288 (490) X>U’Z??“ SS?’Z\?“ 394 (670) CFM (m³ / h) X\Z’UZ?“ X\Z’UZ?“ 283 (480) 288 (490) 218 (370) 218 (370) 247 (420) 247 (420) High SZ 36 39 44 Med 33 33 SZ 37 27 27 31 32 dB(A) Dimensions (H x W x D) in.(mm) Weight lbs.(kg) Liquid (Flare) Gas (Flare) Drain 28 @U??? Btu/h /  Connection pipe diameter ASUA14RLAV /  Med Sound pressure level ASUA12RLAV ASUA9RLAV   X?Q‰XS?_\?Ž ‹   @?‰@S@\£S@‰SSX£Q‰@ZSX’X[Z£[>?£X@Z“ 20 (9) ¤@U’\SZ“ in.(mm) ø 1/2 (12.70) ¤@[SX’@SQ“¥%9¦•¤ZQ’@ZQ“‰¤X@SX’@\[“¥:9¦ ) M              K  M%     Q?’X\[K“9§\[’@>UK“Œ§       >Z?’SZK“9§[Z’XS>K“Œ§ Ž  M%     [?’X@@K“9§\?’@Z\K“Œ§       U[’QSK“9§US’\@K“Œ§ ‹  MXZ ’[Z“Ž   M? ’?“’:    ‰%    “ Built-in protective functions may limit capacity or shut off unit if unit is operated outside of unit design operating temperature ranges. VRF Low noise Auto swing louver Electronic Expansion valves are  ‰      ;     &+  /      ensures that the air direction corresponds to the mode selected. 27dB(A) (ASUA7/9) Indoor unit 1 2   3  Compact size Width Powerful output in a compact design Step   31-1/8 in. (790mm) ‹             ’S‰@X >?  “           Lambda type heat exchanger. 4 Easy maintenance The front panel can be removed for easy access during maintenance. Symmetrical design ;           Open panel High power DC fan motor Ž  Œ    Ž  ; K    Dimensions ) M%**        :   Wireless Controller. Unit: In (mm) Models: ASUA7 / ASUA9 / ASUA12 / ASUA14 Q‰@ZSX’X@Z“ @?‰@S@\’X[Z“ 31-3/32 (790) 21/32 (16.7) 18-1/2 (470) X?‰[Q’ZS?“ @Z@\’X4) XZ‰S@SX’\\?“ 18-1/2 (470) X?‰[Q’ZS?“ +"+[+"+> +"+@X+"+@U M N Refrigerant pipe flare connection O Drain hose connection Liquid ¤@U’\SZ“ Gas ø 1/2 (12.70) Drain Hose %9@[SX’@SQ“ :9ZQ X@SX’@ZQ‰@\[“ 9   M/¨XS‰ZQ’\??“ 29 Wall Mounted Models ASUB18RLAV ASUB24RLAV Stylish, slim and elegant, these popular wall mounted units are perfect for smaller rooms where a clean, aesthetic design is preferred. Variable speed DC fan motors deliver heating or cooling quietly and comfortably. Compact & Slim design Stylish, slim and elegant, these popular wall mounted units are perfect for smaller rooms where a clean, aesthetic design is preferred. Variable speed DC fan motors deliver heating or cooling quietly and comfortably. 39-9/32in. (998mm) DC fan motor Specifications ASUB18RLAV Model name Power source Capacity Cooling Heating Input power Airflow rate High 18,000 kW 5.3 7.0 Btu/h 20,000 24,000 kW 5.9 7.9 W 35 64 494 (840) 647 (1,100) CFM (m³ / h) 453 (770) 536 (910) 406 (690) 430 (730) High 41 48 39 43 Med dB(A) in.(mm) Dimensions (H x W x D) lbs.(kg) Weight Liquid (Flare) Gas (Flare) Drain 30 35 35 Low Connection pipe diameter 24,000 Btu/h Low Med Sound pressure level ASUB24RLAV Single phase, 208-230V , 60Hz 12-19/32 × 39-9/32 × 8-31/32 (320 × 998 × 228) 31 (14) ø 3/8 (9.52) in.(mm) ø 5/8 (15.88) ø 15/32 (12) [I.D.] ; ø 5/8 (16) [O.D.] Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 80°F(26.7°C)DB/67°F(19.4°C)WB,and outdoor temperature of 95.0°F(35°C)DB/75°F(23.9°C)WB. Heating : Indoor temperature of 70°F(21.1°C)DB/60°F(15.6°C)WB,and outdoor temperature of 47°F(8.3°C)DB/43°F(6.1°C)WB. Pipe length : 25ft.(7.5 m), Height difference : 0ft.(0 m) (Outdoor unit - Indoor unit). Built-in protective functions may limit capacity or shut off unit if unit is operated outside of unit design operating temperature ranges. VRF “Vertical airflow” provides powerful floor level heating Air conditioner filter features ft.(m) 7 (2.1) 16 Ion Deodorization Filter (24/30) Organic coating fin used heat exchanger 3 (1) 0 10 (3) 46 20 (6) Outside air conditions: 35.6oF (2o C) 60% Operation contents: Heating Set temperature (Max set temp) 86oF (30oC), Air flow Hi Vertical flap : Downward Horizontal flap : Center o 40 (12) ft.(m) 30 (9) 92 90 88 86 33 32 31 30 Apple-catechin Filter 84 (oF) 29 (oC) Pre Filter Power diffuser (full open) Antibacterial deodorizing pre-filter with special ceramic powder Long-life* Ion Deodorization Filter “Horizontal airflow” does not blow cool air directly atft.(m)the occupants in the room The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic. 7 (2.1) 3 (1) Apple-catechin Filter* 0 10 (3) Power diffuser 20 (6) Outside air conditions: 95oF (35oC) 40% Operation contents: Cooling Set temperature (Min set temp) 64oF (18oC), Air flow Hi Vertical flap : Upward Horizontal flap : Center 30 (9) 40 (12) ft.(m) 58 60 62 64 (oF) 15 16 17 18 (oC) Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples. *The filter can be used for approx. 3 years if it is washed under water to restore its surface action when it is dirty. *Using different filters at both sides. Easy maintenance Note: IR Receiver is standard for communicating with Optional Wireless Controller. Simplification of drain pan cleaning improves maintenance-ability. Dimensions Unit: In (mm) Models: ASUB18 / ASUB24 12-19/32 (320) 39-9/32 (998) ø1-1/4 (32) ø5/8 (16) ø15/32 (12) 1 (25) 20-15/32 (520) 23-7/32 (590) 28-3/8 (721) 8-31/32 (228) ASUB18, ASUB24 20-15/32 (520) M N Refrigerant pipe Liquid flare connection Gas O Drain hose connection Drain Hose ø 3/8 (9.52) ø 5/8 (15.88) I.D. 15/32 (12), O.D. 5/8 (16) Drain house: L=26-3/8 (670) 31 Comparison Table of Controllers Controller Individual control Wired Remote Controller Type Simple Simple *1 Remote Remote Controller Controller Centralized control Wireless Remote Controller Central Remote Controller Touch Panel Controller System Controller (Software) UTY-RNKU UTY-RSKU UTY-RHKU UTY-LNHU UTY-DCGY UTY-DTGY UTY-APGX SU MO TU WE TH FR SA 7 3 6 9 12 15 18 21 Model name Max. controllable remote controller groups Max. controllable indoor units Max. controllable groups 1 1 1 1 100 400 1600 16 16 16 16 100 400 1600 - - - - 16 400 1600 On / Off Air conditioning control function Operating mode setting - Fan speed setting Room temp. setting - Room temp. set point limitation - - Test operation - Up/down air direction flap setting - - Right/left air direction flap setting - - Group setting - - - - RC prohibition - - - - Anti freeze setting - - - - - - Failure - Display Defrosting - Current time - - Day of week - - - - - R.C. prohibition Cooling/heating priority - Address display - Schedule timer Period On/off per day On/off per week Timer - - Economy mode setting - Week - - - Week Year 4 - - - 20 20 72 28 - - - 140 140 504 On/off timer Year - - - - - Sleep timer - - - - - - Program timer - - - - - - 10 10 10 - - Day off Control - - - - Min. unit of timer setting(Minutes) 30 - - 5 Status monitoring system - - - - Electricity charge calculation - - - - Error history *2 *2 Emergency stop - - - - Control via internet - - - - - - E-mail notification for malfunction - - - - - - - *1 "Operation" setting is not available for this model. *2 This function is available only through external input. Controller Type IR Receiver Unit IR Receiver Kit UTB-YWC UTY-LRHYB1 Converter & Adapter Network Converter BACnet® Network Converter Gateway for LonWorks® Signal Amplifier Service & Monitoring External Switch Controller Service Tool Web Monitoring Tool Model name 32 UTY-VGGX UTY-VLGX UTY-ABGX UTY-VSGX UTY-TEKX UTY-ASGX UTY-AMGX VRF    Design Simulator Software which quickly performs model selection and creates material for model estimation in the VRF initial design stage. +                 ª    +              +               + K+99 ’9«“* 89 ’*+“‡   +       ’Œ (‡“ 8 ‰     ; Controller Wired Remote Controller Max. controllable 16 indoor units F UTY-RNKU The room temperature can be controlled by detecting the temperature from the built-in sensor     § ‰ Œ;9 ;& K   @\     " X              Max. controllable Simple Remote Controller 16 indoor units F F UTY-RSKU UTY-RHKU (Without ability to change operation mode) Compact remote controller provides access to basic functions UTY-RSKU " @\                     ;     ‡     UTY-RHKU Without ability to change operation mode Wireless Remote Controller Max. controllable 16 UTY-LNHU F indoor units Simple and sophisticated operations with a choice of 4 daily timers  e +      @\     daily timers 4 Built-in timers Select from 4 different timer programs: : : ‹   Program timer: The program timer operates the ON and OFF timer once    XU   Central Remote Controller UTY-DCGY Central control of small- and medium-sized buildings and tenants. %        @??     Z &&    "  ;  ;    (‡          9   ;  K   [    M(  K  '  * ‹  UTY-LNHU Max. controllable 100 Indoor units Max. controllable 16 groups Easy Installation &     ;      separately.   ‡ ;      K           ‡    33 K   Touch Panel Controller 8 ‡    400      UTY-DTGY / ‰[Z‰ &&   /K9( ;      ;          )       ¬     " U??         X ; ;’% / “      K   [    M( K  '   * ‹  System Controller 8 ‡       4 _*   ;  UTY-APGX 8 ‡    The System Controller’s advanced integrated monitoring & control of VRF network system provides monitoring & control of small to large scale buildings. 400      8 ‡    1,600 "   ‡ U_*   ; @\??           U??                                 ;       K   [    M( K  '  * ‹  ( ;    ’:  “ "§+    IR Receiver Unit IR Receiver Kit 9  ;    Œ * K   IR Receiver Unit IR Receiver Kit Œ * K   UTB-YWC UTY-LRHYB1 Necessary to control all duct type models by Wireless Remote Controller Cassette type indoor unit can be controlled with Wireless Remote Controller K  ª+   8 ‡    Network Converter 16 )   K     UTY-VGGXZ1 &            ;         _*   ;  ‹       ;            34 ’"&Š‰_''«­@“ _* Network Converter for LONWORKS® 8 ‡    8 ‡    4 "   §8 UTY-VLGX 128            _*   ;   /:)W:*¯ ®            ‰§8 &"&Š‰_/'«           _*   ;    §8    /:)W:*¯ ®   " @XQ%         )  K   /:)W:*¯ ® BACnet±Gateway    8 ‡    8 ‡    4 400 _*   ;  UTY-ABGX      ’"&Š‰_/'«“ 8 ‡    1,600      &_*   ;        § 8  ;  (       @\??      §+K  ®            K  +)%+Ž*+(  ®@SZ‰X??U§+K  ®+   K  ’§‰+K“ §+K  ®%‹ (    K   U_*   ; ’@\??    U??     “  ; K  ;§&/ CD-ROM (Software) Software Protection Key "§+    External Switch Controller UTY-TEKX Air conditioner switching can be controlled by connecting other sensor switches %       K ‰¯;      (‡   K         :):*     8        &               K ‰;              ª8    Service Tool    8 ‡8      8 ‡8                400 UTY-ASGX 100 Extensive monitoring and analysis functions for installation and maintenance :      ;                 ;       ‹K " U??    ’  _*   ; “           &       ;         "§   ’ “ Computer not included. "§+    Web Monitoring Tool UTY-AMGX 8 ‡       4 _*   ;  "§+    8    Product features &    ;    ;  ;   ;       (          ;             ”@ *¬              9                 ¬                &            ;   +     ;        8       ¬      ¬ ;%   (‡  1,600 ”@M"     ; ¬ 35 Central Remote Controller Max. controllable 100 Indoor units UTY-DCGY Max. controllable Central control of small and medium-sized buildings. The operation status of all indoor units can be viewed at a glance on a large LCD monitor. 16 groups %         @??     Z &&    "  ;  ;    (‡          9   ;  ‹    [    M( K  '  * ‹  User friendly operation :      ;       %   ;      Function Menu      ;     Registration indoor unit Function button @ @        ;   76°F Operation guidance System overview %          ’8 ‡@\   “ %   ‡   Group : Hallway Group : 3F Group : Division A Group : Division B Group : Division C Group : Tenant B Group : Tenant C Group : 2F Group : Tenant A ( ;     36 _* Functions Diverse control of indoor units %    ’: :  8  &  ( ;    +     “ Weekly timer :Œ;     ;   combinations. QX’XQK“ QX’XQK“    76°F Weekday [>’X\K“ [>’X\K“ [>’X\K“ [>’X\K“ QX’XQK“ QX’XQK“ Weekend Holiday QM?? @XM??  @M?? \M?? >M?? Time Remote controller prohibition (All, On / Off, Automatic clock adjustment : The time setting for all controllers on the ;      ; Mode, Temp, Timer, Filter) : R.C prohibition setting prohibits individual remote control operation from this controller *       upper and lower limitation Error history 64°F 64°F 50°F   X??   +     ;  troubleshooting. 86°F 86°F 86°F Easy Installation &     ;        ;   ‡ ;      K        wall or installed on the wall. Setting pattern 1 +            Indoor unit registration Setting pattern 2 Ceiling ‹ ;  %       start Œ§:« Wall Control panel + Power supply unit Control panel Wall %       finish Specifications UTY-DCGY 8   K  ‹  ‹ ; 9  ’Ž‡Œ‡9“ ’“ Œ  ’“ ‹ ;"  9KZ_ @??‰XU?_Z?‰\?Ž   U‰XSSX‡\‰SQ‡@’@X?‡@\X‡X\“ S‰X>SX‡Z‰Z@\‡@‰@[SX’>>‡@SZ‡S>X“ @?>’S?Q“ @XZ’SZZ“ ‹  / K  ‹ ‹ ;"  K      37 & ‹ K   Max. controllable 400 Indoor units UTY-DTGY Ž ;  ;        [Z &&‰/K9   / ‰[Z‰ &&   ; ( ; ‰     ;     ;    )        ¬     " U??        K   X ; ;’  “       ‹    [    M( K  '  * ‹  Functions 2012 [? [? [Q [\ [\ *  [? [Q [? [? [X +    Easy operation Easy maintenance ( ;‰ ‰   ‰ '  "%  ’'"%“     ;  ) ‰                ( ;‰ ‰     :     ;        ;      ‰  "‰ ‰   ; §             •§             38 _* Up to 400 indoor units can be controlled Group A Group B %           ( ;    +          ‡       ( ;     Function Versatility " U??        8                  ’X?   ;“ ( ;     ’   ‡      “ &         ‡   K_   ‹K      & ‹ K   9        ;"§ %     ‡   Easy installation & ‹ K    ¬         ; )        ¬         %           Automatic clock adjustment &                 ; Specifications 8   ‹ ; 9  ’Ž‡Œ‡9“ ’“ Œ  ’“ %   UTY-DTGY @??‰XU?_Z?\?Ž @?‰@U’X\?“‡>‰@@@\’XU\“‡X‰@Q’ZU“ U@@Q ’X@Z?“ "§X? 39 ; K   Max. controllable Software 4 VRF network systems UTY-APGX Max. controllable 400 ; K        ª   _*   ;  Outdoor units +             ‹K " U_*   ; ’@\??     U??     “        ; K   ‹          +  ( ;      Max. controllable 1,600 Indoor units User friendly views and operation Kª: M&  ;      ;         ( ;              K        ;    Click & Operate the whole building! View options: Site View, Building View, Floor View, List View Click & Operate any specified unit(s)! Alternate between views at the press of a button. Site view List view Batched control of defined groups Building view Batched control of selected units The floor layout drawing can be imported to show the actual building layout. Click & Operate the whole floor! Floor view 40 Click & Operate the unit ! VRF VRF Schedule control Remote centralized control +                            ’ @US    ;“ +           ;     ;    ;  ; K   ;    ;           /+)   K     ¬ _*K     _*(‡       VRF Controller :       8 ‡U_*   ;   Internet or Telephone Line or LAN VRF Explorer K  8     ‹   Error display & E-mail notification (   ;  ;   ‰              ‹  ;9 8    Operating & control record Electricity charge apportionment 9 ;  ;         +                   _*;     ;        ’K        ; S  ; ; “ Prohibition Setting   ; K               ’       “ Multiple language display Energy used by each unit is calculated Energy apportioned by the outdoor unit to each indoor unit is calculated & + & + ‹    [    M( K   '  * ‹  & § & § Security Support ( ;/( ;  &  ;                    Energy saving management Option Optional features for additional energy savings: ‹ K :  :  "  K   ;  %  "  *  :  & K & K Electricity charges by tenant are calculated &       ;;             ;    ; ;              ;  The energy used by each indoor unit and the energy apportioned by the outdoor unit are added together to calculate the total amount of energy used. %     ; Operation Requirements ; K   ( ;    ¬    ‰SX‰  \U‰ Œ    ‹K   Œ «‹‹S   + _*9   &        & + & § & K Electric Bill Electric Bill Electric Bill +    ; Indoor unit total energy used 41 Control System Diagram Building Management Air Conditioning Central Control System Controller (Software) UTY-APGX Air Conditioning Individual Control Wired Remote Controller UTY-RNKU System Outdoor unit USB Adaptor *2 Indoor unit (Field supplied) Internet or Public Telephone Line Simple Remote Controller UTY-RSKU Remote/Monitoring side Touch Panel Controller UTY-DTGY Signal Amplifier UTY-VSGX Simple Remote Controller UTY-RHKU Without master control IR Receiver Unit UTB-YWC Central Remote Controller UTY-DCGY Wireless Remote Controller UTY-LNHU General-purpose Building Control Computer IR Receiver Kit UTY-LRHYB1 Connectable to various sized BMS/BAS*1 BACnet ® Gateway (Software) UTY-ABGX USB Adaptor *2 (Field supplied) or Network Convertor (BMS / LONWORKS® ) UTY-VLGX Card-key External Switch Controller UTY-TEKX For single split (Field supplied) Web Monitoring Tool (Software) UTY-AMGX Service Tool (Software) UTY-ASGX USB Adaptor*2 Internet or Public Telephone Line (VRF system side) (Field supplied) (Monitoring side) *1. BMS/BAS: Building Management System / Building Automation System *2. USB Adaptor is U10 USB Network Interface of Echelon® Corporation. 42 Network Convertor UTY-VGGX USB Adaptor*2 (Field supplied) Transmission line (VRF Network) LONWORKS ® Network Module link Ethernet Remote controller line Signal line(Single split system) USB cable Group Remote Controller line VRF Airstage Portal portal.fujitsugeneral.com What’s on the Portal? Tools for Engineers and Contractors The Airstage Portal provides a single source for all information for Fujitsu Airstage VRF systems. From the Airstage Portal, all registered users have access to: Manuals, Literature, Design Simulator Software, Commissioning Forms, Troubleshooting Guides, Design & Technical Manuals and Online Training. ´+ /  :   ´+  8   ´9   9   Additional features, such as the Airstage Project Manager, are available to Fujitsu Reps, Fujitsu Distributors and Fujitsu Sales Engineers. The Airstage Project Manager supports projects from the design stage through completion and ensures clear and effective communication between all Fujitsu team members. ´&   ' ´%    _  ´¬ ;+^   The Airstage Project Manager applies technology to simplify project management and ensure a successful VRF installation. A central place for project members to coordinate. Who Has Access to the Portal? ´%   +  * ´Engineers ´ *  8 ’*8“ ´K    ´ 9   ´  (  ’(“ Information & Downloads Technical Information Training ´9  + ;  ´*       on-site training classes ´/          Airstage features Warranty & Commissioning ´ K   *  ´‹ (‡  Œ  ;K    ´‹  %    9   Tools for Fujitsu Sales Team Maintain Projects ´" 9    ´&     Submittals & Closeout Documentation ´+   ;   submittals & closeout documents ´K   *    closeout documents are archived for future reference Warranty ´‹   ;  43 &  Software Control and Monitor Up To 100 UTY-ASGX Outdoor units (‡       ;              Control and Monitor Up To :      ;           9          ‰  ‰     ; : _*   ;   ‡   U??         :                                               &   ;           ;           &   _*   ;  K                      K_  ;    create commissioning report. K    ;        "§   *1 (included) K     _*   ;   ‰      "@?"§   400 Indoor units Wiring connection Refrigerant piping Indoor unit USB adapter (included) Transmission line Indoor unit *USB Adapter is U10 USB Network interface of Echelon Corporation. ® Functions @“; / 9 ;               ;  in a list form. X“(¬ 9 ’9  “ 9 ;                      &                             ;         S“(¬ 9 ’/ “ 9 ;                       ;    &                              ;       error occurs. U“:  Ž ; &              ;   & ;    ;        K_  44 (Field supplied) Easy connection using USB adapter VRF Z“( Ž ; m 9 ;         &      ¬  ; ; Z?    ;          \“* 9    :     ;    "       ; ;   ;        [“K   &  9                                +            ‡   K_    Q“)  &   ;+ ; +        _*;      ;         9) Remote Setting            ; @?“; &   &  ;        ;      ; 11) Software Version @U“( 8 ;*  &        ¬   ; Œ           ;              K_  12) Central Release ) M&  ( 8 ;*  ! &      ;          *   :  8    &    /                  ’     temperature limit). @Z“&' %   @S“8 ) Œ  +            9        ’         “                K_  PERSONAL COMPUTER SPECIFICATIONS +&       8  ®Œ   ® :  ;  8  ®Œ   ®«‹‹  ’(   S  “ 8  ®Œ   ® Vista ®Ž ‹§ (  ’(   X  “ 8  ®Œ   ®[‹  ’(   @  “ CPU Intel ® Pentium ®K ®+89+  &89 &8@'Ž  Ž99 10 GB or more of free space 8 ; @'§’_ [“Z@X8§’«‹“   Interface "§   "@?"§)  %        ; Required Software %   (‡ \? [? Q?+  ® Reader® 9.0 or later *¬Ž   K9‰*:8 ‹  / K9‰*:8Œ¯;"@?"§+   ‹      45 Design Simulator Easy Equipment Selection, Complete Selection Output, Reliable Project Management Design Simulator makes it easy to select equipment for complex building air conditioning systems. The software output contains all important design data including: Equipment Schedule, Piping Layout, etc. (all of the documentation needed to estimate a project.) Design Simulator simplifies the design process. To design a system, just select the indoor unit types, designate the groups, and the software will automatically select the outdoor unit and create the piping and wiring diagram. Design Simulator also checks all of the equipment information to ensure proper installation. Step 1 Select the model Choose the model for each system. Step 4 Piping Length / Piping Diagram Piping diagram is created automatically. As piping lengths are entered, system automatically calculates refrigerant charge. Step 2 Select the Indoor Unit Choose the unit types and the conditions and the software will select the correct indoor unit. Indoor unit can also be selected manually. Step 5 Wiring / Controller Diagram Automatically creates the wiring diagram. Simple grouping functions create a custom wiring diagram for the project. Step 3 Select the Outdoor Unit Using the Drag & Drop function, connect the indoor unit to the appropriate outdoor unit. Step 6 Select Converters and Central Control Choose additional devices to meet the needs of the project. Setting Software can be customized for any geographic location. Step 7 Report Output Design Simulator creates a project output with all of the project schedules and schematic drawings. 46 Units (US conventional / Metric) Custom Database Function Output Settings Language Setting VRF Software Requirements Sof tw a re Design Simulator Operating System Microsoft Windows XP / Vista / 7 Hardware System Requirements Display Software CPU: 500 MHz or more Memory: 1 GB (Vista), 512 MB (XP) or more HDD: 1 GB or more 1024 x 768 dots or more Internet Explorer 6.0 or more Acrobat Reader 4.0 or more Microsoft Word 2003/2007 Specifications Item Subject model Preferences Model selection Drawing Output data Report format Update Function VRF V-II Multiple language setting (Choose from 25 different languages) Multiple unit setting Project detail information setting Brand/User name setting User option setting Auto mode selection (Indoor unit/Outdoor unit/Piping/Wiring) Manual mode selection Optional parts selection Controller/Adapter/Convertor selection Auto drawing (Piping diagram/Wiring diagram) Auto product information display Material list display Product detail display (Photo, Specifications, Options) Diagrams display (Piping/Wiring) Additional refrigerant volume (Input piping length) CAD data (2D-DXF, 3D-RFA) Word (rtf) CSV DXF Auto update via internet Download the latest data from the Airstage Portal (portal.fujitsugeneral.com) Note: 1. Specifications are subject to change without notice 2. New models will be added as they are introduced. Output Equipment selections and schedules can be output in standard industry file formats. Auto Update Software updates automatically with the latest product data. Request for update Latest information is transmitted Word format Excel format Auto CAD format 2D Data 3D Data (RevitMep data) Wiring and piping schematic drawings user side(PC) Maintains software integrity Maintains software history FTPserver side (PC) Updates product information 47 Building Information Modeling (BIM) FUJITSU provides the Building Information Modeling (BIM) object models and contents for our VRF system and some products to the architect, designer and contractor using Autodesk® Revit® technology from our Website and Autodesk® Seek Website, etc. BIM Object Models Ensure Proper Design „ Many products available We provide BIM data for indoor units, outdoor units, and accessories. We will continue to create and provide products to support the global market. Object models: VRF “AIRSTAGETM V-II” /8 Rooms Multi “HFI” / Energy Recovery Ventilator Files : Indoor units 75 files / Outdoor units 22 files / Options 15 files „ 3D and 2D product data We provide 3D data that is similar to the product appearance. 2D CAD design operations are supported and 2D display is also provided. The data can also be output in other formats, such as DXF and DWG, which are used by other design CAD. „ Installation limitation The equipment installation limitation range is shown. The distance range from the wall, etc., is automatically displayed to make it easy to provide highly reliable layout designs. „ Installation information Other information, such as symbols showing the airflow direction that are required for installation drawings, is built in and can be automatically reflected in 2D drawings. Installation drawings can be created easily. „ Product specifications & Link information Contains the basic information required for air conditioner design, including unit size, capacity, input power, noise, and airflow rate. „ Data volume Fujitsu Revit® files are small, requiring very little system resources. „ Required software Autodesk® Revit® series software • Autodesk® Revit® Architecture • Autodesk® Revit® MEP • Autodesk® Revit® Structure 48 Data format • RFA Product parameter Power source Input power Capacity Airflow rate Sound pressure level Dimensions Weight Connection pipe diameter Refrigerant Material/Color VRF Auto Louver Grille Kit UTD-GXSA-W, UTD-GXSB-W Operation with indoor unit Opened louver Auto Louver can be controlled by remote controller of indoor unit. Up and Down auto swing  Fixed airflow or auto swing 4 angle settings Closed louver Auto-closing louver When operation of indoor unit is stopped, the louver will automatically close. Dimensions Flexible Control W2 Fitting Flange Auto Louver Grille Grille Duct type H2 H1 W1 D1 D2 Unit: in. Model Name W1 W2 UTD-GXSA-W 26-7/8 25-13/32 H1 H2 D1 D2 Wired Remote Controller Wireles Remote Controller 7-3/32 5-13/16 11/32 3-5/16 UTD-GXSB-W 34-3/4 33-1/4 Specifications UTD-GXSA-W Model name ARUL7/9/12/14RLAV Applicable Indoor Unit Power Supply Fixing of Auto Louver Grille Extension Square Duct Limit Net Dimension inch (H x W x D) (mm) Weight Net Gross lb. (kg) Color Louver Motor Accessories Operation range Cooling Heating UTD-GXSB-W °F (°C) % RH °F (°C) ARUL18RLAV Connecting with Control box of indoor unit Screw ¸xing to Flange or Rectangluar Duct 39-3/8” (Max. duct length between indoor unit and grille) 7-3/32x26-7/8x(3-5/16+11/32) 7-3/32x34-3/4x(3-5/16+11/32) [180x683x(84+9)] [180x883x(84+9)] 4.4 (2.0) 5.6 (2.5) 6.7 (3.0) 7.8 (3.5) White Stepping Motor Fitting Flange, etc. 64 to 90 (18 to 32) 80% or less 50 to 86 (10 to 30) 49 Optional Parts Connection Units Outdoor Unit Branch Kit Liquid Pipe Gas Pipe Separation Tube Header Gas Pipe Gas Pipe Liquid Pipe UTR-CP567X Type Outdoor Unit Branch Kit Separation Tube Header (6 Branch) Header (8 Branch) Liquid Pipe UTR-BP567X / UTR-BP180X / UTR-BP090X Compatibility Multiple Outdoor Units Greater than 193,000 (BTU/h) 96,500 to 193,000 (BTU/h) 96,500 (BTU/h) or less 96,500 to 193,000 (BTU/h) 96,500 (BTU/h) or less 96,500 to 193,000 (BTU/h) 96,500 (BTU/h) or less 6-Branch: UTR-H0906L / UTR-H1806L 8-Branch: UTR-HD908L / UTR-H1808L Model Name UTR-CP567X UTR-BP567X UTR-BP180X UTR-BP090X UTR-H1806L UTR-H0906L UTR-H1808L UTR-H0908L For Duct Models Flange IR Receiver Unit Round Rectangular UTD-RF204 UTD-SF045T Auto Louver Grille Kit Remote Sensor Unit For Slim duct type Accurate temperature is possible sensing room temperature using a remote sensor unit. UTD-GXSA-W (For 7/9/12/14 type) UTD-GXSB-W (For 18 type) Type Flange (Round) Flange (Rectangular) IR Receiver Unit Long-Life Filter Auto Louver Grille Kit Remote Sensor Unit Drain Pump Unit 50 UTB-YWC UTD-RS100 Compatibility Duct Type (ARUM24-36) Duct Type (ARUM24-36) All Duct Type High Static Duct Type (ARUH36-60) Duct Type (ARUM24-36) Slim Compact Duct (ARUL7-14) Slim Compact Duct (ARUL18) All Duct Type Duct Type (ARUM24-36) Long-Life Filter UTD-LF25NA UTD-LF60KA Drain Pump Unit UTZ-PX1NBA Model Name UTD-RF204 UTD-SF045T UTB-YWC UTD-LF60KA UTD-LF25NA UTD-GXSA-W UTD-GXSB-W UTD-RS100 UTZ-PX1NBA VRF For Cassette Models Air Outlet Shutter Plate Wide Panel Closes the air outlet when 2 or 3 directional airflow is required. Fresh Air Intake Kit For Compact Cassette type For Cassette type Indoor unit 37.5” (950 mm) Panel 23.5” (600 mm) 23.5” (600 mm) UTG-AGYA-W UTR-YDZC Panel Spacer UTR-YDZB UTZ-VXAA UTZ-VXGA IR Receiver Kit Insulation Kit For High Humidity Wireless Remote Controller sold separately. Insulation Kit 9.5” (242 mm) Panel spacer UTG-BGYA-W Type Wide Panel Air Outlet Shutter Plate Fresh Air Intake Kit Panel Spacer Insulation Kit for High Humidity IR Receiver Unit UTZ-KXGA / UTZ-KXGB / UTZ-KXGC UTY-LRHYB1 Compatibility Cassette Type (AUUB18-36) Cassette Type (AUUB18-36) Compact Cassette Type (AUUA7-24) Cassette Type (AUUB18-36) Compact Cassette Type (AUUA7-24) Cassette Type (AUUB18-36) Cassette Type (AUUB30-36) Cassette Type (AUUB18-24) Compact Cassette Type (AUUA7-24) Model Name UTG-AGYA-W UTR-YDZC UTR-YDZB UTZ-VXGA UTZ-VXAA UTG-BGYA UTZ-KXGA UTZ-KXGB UTZ-KXGC Cassette Type (AUUB18-36) UTY-LRHYB1 For Ceiling Models Drain Pump Unit Type Drain Pump Unit Compatibility Ceiling Type (ABUA30-36) Model Name UTR-DPB24T UTR-DPB24T 51 Applications There are many applications for Airstage VRF systems including such markets as education, healthcare, hospitality, utilities, office buildings, apartment buildings, condominiums, and restaurants. Note: VRF Heat Pump System does NOT provide simultaneous Heating and Cooling. System operates in either Heating mode OR Cooling mode. Medical and Healthcare Facilities VRF gives each patient individual control of their room temperature. Central control ensures that air conditioning is only delivered to rooms that are occupied. „ INDIVIDUAL CONTROL VRF gives each patient or each room individual control of their room temperature. „ CLEAN AIR VRF systems can use ductless indoor units reducing the time and expense of maintaining a HVAC system and eliminating the risk of duct-borne molds and bacteria. „ CENTRAL CONTROL Powerful central control ensures that heating or cooling is only delivered to rooms that are occupied. This provides enormous savings for facilities with revolving occupancy. „ RELIABLE PERFORMANCE Since each refrigerant circuit has the ability to operate independently, a properly designed VRF system can add a layer of security to a HVAC system. If an individual unit needs to be shut down for repairs, the rest of the system can operate normally. „ HEALTHIER FACILITY VRF systems can be integrated with fresh air systems to ensure that air quality meets the needs of the occupants. VRF provides the most comfortable environment for all occupants. „ INDIVIDUAL COMFORT With VRF, each patient can have their own controller to set the room temperature for their maximum comfort. 52 VRF Educational and Religious Facilities In a school, an investment in VRF is an investment in your community. VRF is more efficient than conventional systems, providing financial savings to the school for many years. Also, a quiet VRF HVAC system (as quiet as19 dB) creates a much better learning environment for students. „ HEALTHIER FACILITY VRF systems can be integrated with fresh air systems to ensure that air quality meets the needs of the teachers and students. „ CENTRAL CONTROL Powerful central control can monitor and control individual schools, or an entire college campus, from a single location. „ ZONING Save energy by only heating or cooling the classrooms that are occupied. Set temperature can be pre-programmed to meet the energy budget for the school district. „ COMFORT VRF helps achieve a healthier, quieter, more comfortable and productive learning environment. 53 Multi-Tenant Dwellings VRF improves the quality of multi-tenant buildings while reducing tenant complaints. High quality VRF systems let owners save on energy costs and reduced maintenance costs. With VRF, each tenant has individual control over the temperature setting for the comfort of their home. „ QUALITY By delivering quiet, efficient heating and cooling, VRF improves the quality of multitenant buildings and reduces tenant complaints. „ ENERGY SAVINGS Efficient VRF systems reduce the total energy costs for buildings over most other options. High quality systems reduce maintenance and service costs. „ INDIVIDUAL BILLING Using the Energy Charge Apportionment feature, landlords can easily bill each tenant for the percentage of total energy the individual tenant consumes. „ INDIVIDUAL COMFORT With VRF, each tenant can have their own controller to set their room temperature for their maximum comfort. „ CONVENIENT CENTRAL CONTROL Landlord can monitor and control all indoor units from a central location. Landlord can even troubleshoot or solve tenant complaints remotely. „ QUIET Indoor units as quiet as 19dB ensures a quiet, comfortable living environment for all tenants. 54 VRF Office Buildings and Retail Spaces VRF provides a comfortable work environment for all employees. Zoning ensures that energy is only used to cool/heat occupied offices. Quiet indoor units and precise temperature control creates the most comfortable and productive work environment. „ QUIET Indoor units (as quiet as 19dB) and outdoor units (less than 64dB) creates a pleasant work environment and reduces noise complaints. „ ZONING Save energy by only heating or cooling occupied offices. No more hot/cold calls since each zone or tenant has individual control of the set temperature. „ CONTROL Powerful controls options can manage and monitor entire building from a single location. „ EASE OF INSTALLATION Can be installed in occupied office spaces with minimal disruption to occupants. Can even be installed without disrupting the existing HVAC system. „ FLEXIBLE As tenants and office configurations change, VRF system configurations can also be modified (within original design constraints) to meet the needs of new tenants. „ COMFORT VRF provides a comfortable work environment for all employees. Quiet indoor units and precise temperature control creates the most comfortable and productive work environment. 55 FUJITSU GENERAL AMERICA, INC. 353 Route 46 West, Fairfield, NJ 07004 airstage.fujitsugeneral.com Variable Refrigerant Flow (VRF) Multi-Split AC and HP AHRI Standard 1230 %:>??@ %:@U??@ K   M?@@??Q>S>U K   M?@@?U>XUZ@?@ Fujitsu General (Thailand) Co., Ltd. %:>??@ K   M?@@??[>X\> %:@U??@ Certified number : 272043 Fujitsu General (  ) Co., Ltd. %:>??@ Certified numberM??\?Q^@@?\@*X8 %:@U??@ K   M??\?>(X?UZU*X8 Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd.                                !      "$%&"'()(*+//%8%&(9       $          :   ;        ;                 Actual products’ colors may be different from the colors shown in this printed material. Internet sales are strictly prohibited and unauthorized. Any HVAC systems purchased on the Internet, from an online retailer or any similar e-tailing website, OR where the original factory serial numbers of the display have been removed, defaced, or replaced in any way WILL NOT BE COVERED BY WARRANTY. Distributed by : Part #7-26-FG6005. Printed 5-2012. Copyright© 2012 Fujitsu General America, Inc. All rights reserved.