Temperature Sensors Outdoor Sensor 070e Universal Sensor 071e • UV Resistant Enclosure • Operating Range -50 to 60°C • 73 mm x 114 mm x 38 mm • Silver Plated Zinc Alloy • Strap-on Design • Temperature Well Compatible • Operating Range -50 to 125°C • 9.5 mm OD x 19 mm Indoor Sensor 076e Slab Sensor 079e • Indoor Use Only • Operating Range -50 to 60°C • 73 mm x 73 mm x 21 mm • 316 Stainless Steel Enclosure • Operating Range -50 to 60°C • 5 mm OD x 38 mm Timer The kanmor Timer 032e can be used with kanmor’s Reset Controls 262e, 362e, and 363e. The 032e allows for either 24 hour or 7 day scheduling with either 2 or 4 events each day. With 3 hour temporary overrides or permanent overrides, the 032e is simple to operate based on the user’s needs. Quality Control Solutions for Today’s Hydronic Heating Applications Mixing Reset Controls Integrated System Controls Programmable Thermostats Timer 032e • 24 V (ac) Power Supply and Relay Switching • 24 Hour or 7 Day Programming • 2 or 4 Events per Day • 3 Hour Temporary or Permanent Overrides • Batteryless Backup Mixing Reset Controls Programmable Thermostats With automatic cycles per hour, kanmor Programmable Thermostats balance temperature swings and equipment cycles to increase the comfort of the heating system. Slab sensors and schedules combined with air sensors allow for periods of floor warming and space heating throughout the course of the day. The kanmor Mixing Reset Controls 360e and 361e are an important part of a modern hydronic underfloor heating system. Through outdoor reset, kanmor’s mixing controls provide steadier air temperatures for increased comfort, and they reduce energy consumption due to lower water temperatures. With the use of a boiler sensor, the Mixing Reset Controls increase the system’s service life by protecting the boiler against cold system return temperatures and corrosion caused by flue gas condensation. Programmable Thermostat 510e • 24 V (ac) Power Supply and Relay Switching • One Stage Heat • Auto Cycles per Hour • Two Auxiliary Sensor Inputs • 24 Hour or 7 Day Programmable • Early Start from Setback • Air and/or Slab Temperature Control Mixing Control 360e • Floating Action Mixing • System Pump Contact • Boiler Operation & Protection • Indoor Air Sensor Input • LCD for System Monitoring • Plug-in Wiring Hydronic Underfloor Heating System with a 4-Way Mixing Valve Programmable Thermostat 512e • 24 V (ac) Power Supply and Relay Switching • Two Stage Heat/Heat - Cool • Auto Cycles per Hour • Two Auxiliary Sensor Inputs • 24 Hour or 7 Day Programmable • Early Start from Setback • Air and/or Slab Temperature Control kanmor Control Systems Ltd. 5100 Silver Star Road Vernon, B.C. Canada V1B 3K4 (250) 545-7749 Fax. (250) 545-0650 Web Site: www.kanmor.com © 2003. All rights reserved. Used under license by kanmor Control Systems Ltd. Mixing Control 361e • Variable Speed Injection Mixing • System Pump Contact • Boiler Operation & Protection • Indoor Air Sensor Input • LCD for System Monitoring • Plug-in Wiring Hydronic Underfloor Heating System with a Variable Speed Injection Pump All specifications are subject to change without notice. Printed in Canada. P 188e - 03/03. Integrated System Controls The kanmor Reset Controls 262e, 362e and 363e are able to integrate the underfloor heating system’s water temperatures with the system’s zoning devices three different ways. Outdoor Sensor 070e Timer 032e Reset Control Wiring Center 262e, 362e, 363e The kanmor Reset Controls can be connected to a wiring center to provide an outdoor reset water temperature to multiple zones. The kanmor Timer 032e can be connected to the control to allow for water temperature setback of the system. Boiler Control 262e • Boiler Reset • Two Stage Boiler Operation • DHW Control with Priority • Equal Run-Time Rotation • Remote Display Module 040e Mixing Control 362e • Mixing Reset • Floating Action Mixing • Boiler Protection • Remote Display Module 040e Universal Reset Control 363e Outdoor Sensor 070e Timer 032e RTU 062e, 063e Reset Control • Boiler and Mixing Reset • Floating Action Mixing • DHW Control with Priority • Boiler Protection • Remote Display Module 040e 262e, 362e, 363e Zone Control 369e A single Room Temperature Unit (RTU 062e or 063e) can be connected to the kanmor Reset Controls to provide Indoor Temperature Feedback and room air temperature adjustment. This can be done for a single zone system or for a thermostatic radiator valve zoned system. A kanmor Timer 032e can be connected to the control to allow for air temperature setback of the system. Outdoor Sensor 070e RTUs 062e, 063e Reset Control Zone Control 262e, 362e, 363e 369e The kanmor Zone Control 369e can be connected to the kanmor Reset Controls 262e, 362e and 363e to provide Indoor Temperature Feedback and Zone Synchronization for multiple zones. The Zone Control 369e has an internal timer that allows for the setting of individual zone schedules. • 1 & 2 Stage Heating • Individual Zone Setback • Indoor Temperature Feedback • Zone Synchronization • Cooling Control • Remote Display Module 040e Boiler Control 262e with 2 Mixing Control 362e’s Two Stage Boiler Reset and Two Separate Mixing Reset Zones with Room Temperature Unit Inputs. Room Temperature Units Integrated Zone Control Indoor Temperature Feedback • Fine tunes the supply water temperature based on the heat requirements of the zones. This forces the zones to stay on for longer periods and provides a more uniform flow of heat into the space. Zone Synchronization • The on and off periods for each zone are synchronized and coordinated to provide a relatively consistent load. The consistent load increases the overall efficiency by minimizing short cycling of the heat source. The kanmor Room Temperature Units 062e and 063e provide Indoor Temperature Feedback to either the kanmor Reset Controls 262e, 362e or 363e or the kanmor Zone Control 369e. The large display is backlit for easy reading under any lighting condition. The 062e and 063e allow for zone temperature adjustment, schedule overrides and monitoring of the room temperature. The 063e allows for the connection of up to 3 remote sensors. These sensors can be a combination of 076e Air Sensors and 079e Slab Sensors. Room Temperature Unit 062e Room Temperature Unit 063e • Four Access Levels • Setting Range 2 to 38°C • Monitor Menu for Highest and Lowest Room and Outdoor Temperatures • Four Access Levels • Setting Range 2 to 38°C • Monitor Menu for Highest and Lowest Room and Outdoor Temperatures • Three Remote Sensor Inputs for Air and/or Slab Temperature