Transcript
P3 Relay 2 Pole, Change-Over Contacts 3 Pole, Change-Over Contacts 10 A
30V DC1
5A
48V DC1
10 A 250V AC1 Contact Specifications - Single Contacts
8 Pin Relay
Materials : Standard
Silver Alloy with gold flash
Contact Type
Single contact
Nominal switching capacity
250 VAC 10A AC1 2500VA
Electrical Life Expectancy
apprx. 100,000 operations 250VAC , 10A AC1 (1200 cycles/hr )
Max. insrush current
20A
Switching Current Range
20mA to 10A
Switching Power Range
0.3 VA (W) to 2500 VA
Contact Resistance
20m Ω Max.
Specifications 7
11 Pin Relay
Mechanical Life Expectancy
> 2 x 10 operations
Mechanical Switching Frequency
20 Hz
Pull-in-time typical
12 ms at DC / 13 ms at AC
Release Time typical
8 ms at DC / 3 ms at AC
Shock Resistance
AK : > 10g
Vibration Resistance
5g 10…..150 Hz
Di-Electric Strength between coil and contact
2500 VAC
between NO & NC
1500 VAC
between adjacent contacts
2000 VAC
Insulation Resistance between coil and contact
200 M Ω min. @ 500VDC
Pull in Voltage
≤ 0.80 x Un (for AC) ≤ 0.75 x Un (for DC)
Drop Out Voltage
≥ 0.15 x Un (for AC) ≥ 0.10 x Un (for DC)
Nominal Coil Power
2.2 VA (AC)/ 1.3 W (DC)
Mounting Direction
any
Ambient Temperature
-40°C to +85°C
Storage
-40°C to +55°C (for AC relay)
Operating
-40°C to +70°C (for DC relay)
Protection Standard
IP 40
Weight
app. 80 g
8 pin Relay
11 pin Relay