Preview only show first 10 pages with watermark. For full document please download

Pa-5125/5250 5375/5500

   EMBED


Share

Transcript

PA-5125/5250 5375/5500 Power Amplifiers Rear View Features • • • • • • • 125W/250w/375w/500w/ 70V or 100V or 25V/4 Ohm power amplifier (PA-5125/PA-5250/PA-5375/PA-5500) Thermal protection by muting input signal (typically 85 deg at heat sink) Momentary short circuit protection Dual speed auto cooling fan Manual reset circuit breaker for AC mains and DC input Balanced input signal with gain control and selectable grounding option AC or DC operation for uninterrupted operation during power failure Description The PA-5500, PA-5375, PA-5250 and PA 5125 are reliable, heavy-duty single-channel power amplifiers designed for demanding sound system applications. All models feature an XLR balanced input, with adjustable input sensitivity from -40 to 0dB. A parallel male XLR connector enables convenient amplifier linking in multiple amplifier installations. Automatic thermal protection circuitry is provided and an "idling" circuit protects against thermal runaway. A two-speed fan helps ensure reliability, switching to high-speed when the amplifier is under heavy load. Front panel LEDs indicate output levels of -40dB, -10dB and clipping, as well as protection circuit activation. A ground-lift switch is provided to isolate signal ground from chassis ground. The outputs are 4 Ω, 70V, or 100V. The units can be powered by 220 - 240VAC or 24VDC, enabling the unit to be used as part of a portable PA system, or connection to a standby power supply for emergency operation. All models are packed in a 3.5" high (2 RU) rack-mount enclosure. Technical Specification PA-5125 PA-5250 PA-5375 PA-5500 125W 250W 375W 500W Output impedance (max load) 80 Ohm 40 Ohm 27 Ohm 24 Ohm 4 Ohm output voltage 22.3 V 31.6 V 38.7 V 44.8 V Rated output (100V, RMS) Frequency response 70 Hz -18KHz @ 1KHz +/-3 dB S/N Ratio >70dB @ 1KHz, 1V THD + D <0.18 % Input signal 1V / 10K Ohm; balanced via XLR female Input gain controls -40 to 0dB Protections Thermal. Short circuit, Overload, Fuse Cut off temperature 75 Deg C Cooling system Auto temperature controlled fan speed Indications -40dB, -10dB, clip, protect, power Power requirement 240V ac or 24VDC Power consumption (240Vac) 290VA(1.3A) 440VA(1.8A) 580VA(2.4A) 720VA(3A) Current consumption (24VDC) 8A 15A 20A 25A 0.2A 0.25A 0.3A 0.32A Standby current (24VDC) Dimensions (W X H X D) Net Weight (kg) 482 x 88 x 335 mm 12 13 16 18 513-12 Sangdaewon-Dong, Joongwon-Gu, Seongnam-Si, Gyeonggi-Do, South Korea Tel: +82-31-733-1060 Fax:+82-31-733-1059 www.kodio.biz Trade Marks ® 2006 #06008391