Transcript
VERY IMPORTANT Do not install and use your portable air conditioner unit before carefully reading this instruction guide. Please retain this manual brochure for product warranty and future reference
PA-91/PA-120 INSTRUCTION FOR USE
CAUTION 1." DO NOT BLOCK VENTILATION "! Please make sure the inlet and outlet ventilation is not blocked at all times. 2. Operate this unit on a horizontal surface to avoid water leakage. 3. Do not operate this unit in an explosive or corrosive atmosphere. 4. Operate this unit in an ambient of 32or less. 5. The unit should not be operated in heating function an indoor ambient temperature above 7℃or lower23℃. Clean air filter periodically to enjoy the most efficient cooling. 7. When the unit is shut off, please wait at least 3.5 minutes before restarting this is to prevent the compressor from being damaged. 8. This unit needs at least 7 Amps of electricity to have its compressor operational. To avoid the household electricity block out, please do not use any extension cord for this unit. 9. This unit is for indoor cooling, heating and dehumidifying. 10. When boot-strap, the fan will operate but the compressor will start up after the cooling alarm flashes for three minutes ●
MOBILE AIR CONDITIONER
In heating function, the heating alarm will flash for 3.5 minutes
before the compressor and fan start up.
11. When the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid hazard. 12、The batteries must be removed from the appliance before it is scrapped and that
CONGRATULATIONS ON YOUR SELECTION OF A QUALITY PORTABLE AIR CONDITIONER
they are disposed of safely. 13. The air-conditioner can be connected only to a supply with system impedance no
PORTABLE AIR CONDITIONER
more than 0.219Ω.In case necessary, please consult your supply authority for system
Your Air Conditioner has been designed and manufactured to the
impedance information.
highest standards of modern engineering.
14.The devices should be installed at minimum distant of 50CM from the wall or other obstacle. 15.This appliance is not intended for use by persons (including children) with
Its many features not only include remote control Operation that lets you control all functions with easy and convenience.
reduced physical, sensory or mental capabilities, or lack of experience and
- Moves easily from room to room on easy glide castors
knowledge, unless they have been given supervision or instruction concerning use
- No installation required-just plug into any household
of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
power outlet - Refrigerated air system design cools instantly whenever you want it - Dehumidified filtered air cycle for improved breathing conditions due to powerful dehumidification process -If remote control function is not required, your one touch electronic pad provides easy to identify manual operation -24 hour programmable timer that can be used with either the air conditioning or dehumidification setting -Unique sleep control function -220~240 Volt 50Hz operation -1.6 meter cord with plug
UNPACKING INSTRUCTIONS 1. Place the unit in the correct upright position before unpacking.
7. Cool inlet
2. Cut the two packing straps.
8. Cool Air filter
3. Slide the carton in an upwards motion and it will release from the base.
9. Hot inlet
4. Grip the carry handles located on either side of the unit and carefully lift until it slides
10. Hot air filter
out of the foam base.
11. Drain pipe
5. Disconnect the tie-in inside the exhaust tube and take out the exhaust tube 6. Install the exhaust tube on the unit before operating the unit.
CONTENTS 1 / Air control unit 2 / 1-remote control unit
NAME OF THE PARTS 1. Control panel 2. Remote receiver 3. Adjustable air vent 4. Joint tube 5. Exhaust tube 6. Up drain pipe
CONTROL PANEL & DESCRIPTION OF FUNCTION
1.POWER KEY
Press to turn unit "ON" or "OFF".
2. FUNCTION
Press this key to select refrigeration, heat or dehumidification. or cooling.
3. TEMPERATURE REGULATION KEY (UP) During cooling function:This key raises the preset temperature by 1℃ each time it is pressed to a maximum of 30℃。 During heating function:This key raises the preset temperature by 1℃ each time it is
7. PROGRAMMABLE TIMER Programmable timer ON/OFF key. TIMER-ON: The timer-on is used to turn on the unit automatically after the set time is over. 1. Press the "TIMER" key at stand-by status to set the time desired. 2. Once the set hour has come to an end, the unit will turn on automatically. 3. Press the "POWER" key before time out, the setting time will be canceled and the unit will turn on. TIMER-OFF: The timer-off is used to turn off the unit automatically after the setting time is over.
pressed to a maximum of 25℃
4. TEMPERATURE REGULATION KEY (DOWN) During cooling function:This key lowers the preset temperature by 1℃each time it is pressed to a minimum of 17℃ .
1). Press the "TIMER" key at stand-by status to set the time desired. 2). Once the set hour has come to an end, the unit will turn off automatically. 3). Press the "POWER" key before the time out, the setting time will be canceled and the unit will turn off.
During heating function:This key lowers the preset temperature by 1℃ each time it is pressed to a minimum of 15℃.
5. L.E.D. DISPLAY
8.SLEEP CONTROL FUNCTION When setting the "sleep comfort" mode please ensure that you then set the number of hours required and press the timer button till those hours are indicated on the L.E.D
Indicates the temperature or the time setting. After any time set the display will return to the
display. After setting the hours the L.E.D. display will automatically return to the current
preset temperature automatically.
pre-set temperature. To increase this setting "up" press button indicating and for each
6. SPEED
Press to select either LOW, MEDIUM, HIGH or AUTO fan speed. If "AUTO" is selected(During cooling function),”HIGH” or "MEDIUM" or “LOW" will be selected automatically according to the difference between setting temperature and room temperature.
press, the temperature will be increased by 2℃. Likewise to set for a lower temperature press button indicating and for each press the temperature will be decreased by 2℃ During the course of this cycle, to ensure maximum sleep comfort. the micro-processor memory will raise the pre-set temperature 1℃ each half hour to a maximum of 4℃over two hours and then maintain that temperature for the balance of the time set.
Note: In heating function and dehumidifying function, the wind-speed setting is inefficacy because the unit has setted high-speed(heating) and low-speed(dehumidifying).
The portable air conditioner is fitted with a 3 minute compressor delay protection circuit which simply means that the compressor requires 3.5 minutes to start. From either being switched on, or when changing from “dehumidify” to any air conditioning cycle chosen.
9.
ALARM When the water tank is full,"E4" will be displayed on the display panel. To resume
NOTICE
operation, please remove the rubber cap of the drain hose to drain out the water firstly.
This unit can evaporate the condensation and flow out through
After finishing draining the water out, please restart the unit and then the unit can
the exhaust hose automatically.
operate normally.
1. When the unit is in the cooling or heating function, it does not need to install the drain hose. Please make sure that the rubber cap is locked on drain hose, when the unit is running.
REMOTE CONTROL FUNCTION
2. When operating heating function, in order to improve the heating effect or prevent low temperature(lower than 17℃), water full phenomenon will happen . And then we suggest to pull out the “②”rubber cap.
3. When operating dehumidifying function。
1. POWER
Stop/Start switch
“①” rubber cap on drain hose should be pulled out and install a proper drain hose.
2. FUNC
Function “MODE” selector
● Please remove the air exhaust hose, connect a drain hose to the drain hole and lead
3. TIMER
Hourly programming
4. AUTO
Automatic fan speed
5. HI
High fan speed
6. MID
Medium fan speed
7. LOW
Low fan speed
8. SLEEP
Night operation selector
9. TEMP.
Temperature selector
the water to the outside in order to let the dehumidifying capacity more strong.
MAINTENANCE PLEASE DISCONNECT THE POWER CORD BEFORE CLEANING.
AIR FILTER The air filter located on the left hand side of the unit can be removed,
To remove the air filter, please follows the arrow direction and push the filter lightly, and then take out the filter for cleaning.
simply by pulling the frame in an upward motion.
CONDENSER/EVAPORATOR Use a brush attachment with a vacuum cleaner.
CABINET Wipe with a damp cloth and polish with a soft cloth.
POWER SUPPLY (1) Confirm the correct power. (2) Insert the plug into the outlet firmly. In case of dangerous leak, prevent the AC cord from scarring. (3) Don’t pull power wire by force because it will cause damage to power wire.
PLACE FOR USE (1) Because the machine expels hot air, please don’t operate in a narrow place.
(2) In case of dangerous leak, don’t work the machine in a humid place. (3) Don’t place the machine in a sunlit corner otherwise the colors soon fade out of the machine.
HELPFUL HINTS The unit is fitted with a special thermal cut off device. Please ensure the unit is not placed against objects which will obstruct air intake e.g. furniture or curtains as this will affect it's
How to enjoy heating function?
performance dramatically. Do not place the unit in direct sunlight, as this may cause the unit to overheat and turn off.
EXHAUST TUBE INSTALL 1. Circumrotate the wind pipe according to the direction as the arrowhead ① indicates and then the wind pipe can be took out from the unit. 2. Circumrotate the wind pipe according to the direction as the arrowhead ② indicates and then make it connect with the unit.
When operating heating function: 1. Disassemble the subassembly of outlet and the subassembly of exhaust pipe as arrow direction Fig.01 and then exchange the two subassemblies to install. The finished illustration is as Fig.03.
SPECIFICATION
NOTICE ABOUT RECYCLING
MODEL
PA-91
PA-120
POWER SOURCE
220~240V/50Hz AC
220~240V/50Hz AC
COOLING
1100W
1480W
HEATING
950W
1300W
COOLING CAPACITY
2600W
3500W
HEATING CAPACITY
3000W
3500W
MOISTURE REMOVED
50liters /day
60liters /day
AMBIENT
30°C RH80%
30°C RH80%
REFRIGERANT
R410A
R410A
DIMENSION(MM)
330Wx486Dx740H
330Wx486Dx740H
RATING POWER(EN60035)
(CE) N 842/2006: R134A is a kind of fluorinated greenhouse gases covered by the Kyoto Protocol. Its total global warming potential (GWP) is 1300
Your product is designed and manufactured with high quality materials and components which can be recycled and reused. This symbol means that electrical and electronic equipment, at their end-of-life, should be disposed of separately from your household waste. Please dispose of this equipment at your local community waste collection/ recycling centre. In the European Union there are separate collection systems for used electrical and electronic products. Please help us to conserve the environment we live in!
DECLARATION OF CONFORMITY This product complies with the requirements of the directives EMC-Directive: 2004 / 108 / EC Low Voltage Directive: 2006 / 95 / EC declare that the PA-91 and PA-120 are in compliance with the following norms: EN 55014-1:2006 EN 55014-2/Α1:2001 EN 61000-3-2:2006 EN 61000-3-3/A2 :2005 EN 61000-3-11:2000 EN 61000-6-3:2007 EN 60335-2-40/A1 :2004 EN 60335-1/A2 :2006 EN 50366/A1 :2006
EXCLUSIVE IMPORTER IN GREECE: Amiridis – Savvidis S.A. 33, Vas. Olgas avenue P.O. 54641, Thessaloniki, Greece Tel: +30 2310 850107, +30 2310 850108, Fax: +30 2310 867835 45, Akti Posidonos street P.O. 18344, Moschato, Athens, Greece Tel: +30 210 9402064, Fax: +30 210 9402137
[email protected]