Preview only show first 10 pages with watermark. For full document please download

Packaged Air Conditioning Unit

   EMBED


Share

Transcript

.................................................................................................. P125 Packaged Air Conditioning Unit .................................................................................................. .................................................................................................. Packaged Air Conditioning Unit .................................................................................................. Introduction The Reznor Platform 125 series is a new range of packaged Air Conditioning units, providing cooling and heating. They have been developed utilising the proven engineering expertise gained by Reznor, with over 125 years experience of manufacturing HVAC equipment. In order to maintain comfort conditions within a building along with air quality and humidity, a HVAC system must be able to deal with all climatic variables. Reznor’s range of rooftop units comprising models YDSA, YDHA & YDMA have been developed with these factors in mind. Energy Saving Features & Benefits • Free cooling 0-100%, using fresh air to reduce energy consumption by the compressors. • Digital scroll compressor with 10% to 100% capacity control to reduce running costs and provide accurate temperature control • Variable air volume (standard) plug fan technology on all models reduces fan power for demand control ventilation • Optional high efficiency integrated energy recovery (thermal) wheel available on all models • Heat pump option - renewable energy • 10-100% gas modulation for close temperature control and reduced heating costs Technical Features & Benefits Model Range P125 units are for external use and are available in three variants: • Sound blankets for low noise impact • Plug and play controls, compatible with a range of BMS protocols including Modbus, and BACnet • EC Supply air fan provides high efficiency operation and optimum performance - High ESP capability 10 model sizes are available for YDMA and YDHA. 6 models available for YDSA • Pre charged unit - factory tested under controlled conditions Applications • R410A environmentally friendly refrigerant • Power exhaust option • Supply fan control strategy > Constant duct pressure > Constant building pressure > Constant air volume • Reheat pump option - superior part load performance • • • YDMA with 70-100% fresh air YDHA with 30-70% fresh air YDSA with 0-30% fresh air • Cinemas • Factories • Retail outlets and grocery stores • Sports facilities and halls • Warehouses • Workshops • Manufacturing • Public houses and restaurants .................................................................................................. Packaged Air Conditioning Unit .................................................................................................. Make-up-air (Up To 100% Fresh Air) Combination of Make-upair and Recirculation Return Air (Up To 30% Fresh Air) The units are designed to handle both the make-up-air and space comfort load requirements. The units are designed to provide comfort Air Conditioning to single or multi-zone spaces. These applications are typically controlled by a room thermostat. (Mix of Fresh Air & Return Air) The units are designed to condition 100% fresh air in all climates. Ideal for supplying heating / cooling and make-up-air to large areas or to individual applications where the air extraction rates are significant. Units are sized to introduce slightly more outside air volume into the space than the extracted air volume. This make-up-air can provide a slight positive pressure to uniformly distribute the air throughout the building and eliminate air infiltration. Ideal for supplying 30-70% conditioned outside air volumes with mechanical cooling and heating, with the balance being recirculated air. Designed to handle space loads, these units can provide between 0 - 30% outside air volumes. 100% free cooling facility standard on all models within the YDHA range. 100% free cooling facility standard on all models within the YDSA range. YDMA - Make-up-air YDHA - Combination of make-upair and Recirculation YDSA - Recirculation .................................................................................................. Packaged Air Conditioning Unit .................................................................................................. Cooling High efficiency DX system with digital scroll compressors translates into lower operation costs especially if the unit is introducing fresh air during the warm summer months. Other features include: • • • • • • • • 10% to 100% capacity control High EER ECM condenser fans Compressor acoustice jacket Corrosion proof, double sloped drain pan Sound blankets Frost stat, high & low pressure switch Anti-cycle programs Energy Recovery Energy recovery systems thermal wheel recover exhaust air energy and reintroduce it into the conditioned space. When this option is used greater energy savings can be achieved. • • • • • • • • • Integrated power & controls High efficiency enthalpy wheel, up to 76% efficiency Superior sensible & latent performance Minimal cross contamination (<5%) Slide out servicing Optional electric pre-heat (wheel frost protection) Standard filtration Exhaust damper (gravity operated) Ability to handle unbalanced air volumes Dehumidification - YDMA & YDHA The Reznor reheat delivers dehumidified air at the desired temperature. This independent system produces overall year round energy savings and great part-load performance during mild spring & autumn conditions. • • • • Approximately 8 to 10°C minimum temperature rise Modulated capacity High & low refrigerant pressure switches Low ambient operation .................................................................................................. Packaged Air Conditioning Unit .................................................................................................. Heating (option only) When it comes to gas heating efficiency & reliability, Reznor leads the World. The Platform 125 range can be fitted with either gas or electric heating sections as well as offering other benefits: • • • Anti-cycle program Slide-out service and inspection Gas heating > High efficiency condensing gas heater > 10-100% modulating capacity control > 409 grade stainless steel heat exchangers • Electric heating > Thyristor electric heating (0-100% modulation) > 2 or 4 stage control Supply Fan The supply fan is the heart of the system and the one component in a package unit that impacts all other mechanical functions. Platform 125 units exhibit state of the art fan technology and system design. The fan module features: • • • • • • • Construction Designed to provide excellent longevity and continued serviceability whilst withstanding the rigours of outdoor weather conditions. The double skinned sandwich panel construction provides very high thermal efficiency and excellent acoustic performance. • • • • Pre-painted galvanised, 20 gauge, G90 double skin foam panel construction Safe bottom lifting with lifting lugs/holes provided Hinged doors with slam shut auto locking to all compartments Full width doors provide easy access to components • • Direct drive plug fan ECM fan motors Slide out servicing Phase loss protection Fan control options > Duct pressure control > Building pressure control > Adjustable constant volume Direct air volume measurement via microprocessor dispaly Weatherproof hood with bird screen or washable filter Various intake damper configurations Various EU filter grades available .................................................................................................. Packaged Air Conditioning Unit .................................................................................................. Options Heat (Gas) • Natural Gas • Propane (LPG) • 409 grade stainless steel heat exchanger • 2 or 4* stage burner • 5:1 or 10:1* gas modulating burner • High low gas pressure switches Energy Recovery • Total enthalpy thermal wheel 0.35 m3/s to 3.76 m3/s (model dependent) • Electric pre-heat (10, 20 or 30kW) DX Cooling & Reheat Options • Epoxy coated coils available for both Evaporator & Condenser coils • Main DX system hot gas bypass • Low ambient DX system operation • ECM speed control condenser fan • Independent reheat circuit * Twin heat modules only Other Heating Options • 20 to 120kW (model dependent) • Electric heating 20 - 120kW • SCR Thyristor modulation • LPHW heater & Valve control • HR from Supermarket Refrigeration circuit Damper Controls • External 0-10v DC input signal • User adjustable 2 position control • 4 position control from 2 external contacts • Economizor package with CO2 control • Free Cooling 0 - 100% economiser package. Supply Fan • Backward curved direct drive fan • Backward curved plenum fan with ECM • High low volume fan control • Duct static pressure control • Building static pressure control • Constant supply volume • Adjustable constant speed volume control (winter / summer) • High efficiency F7 filters Curbs • 400mm or 915mm high • Double skin, sandwich panel construction using galvanised steel Intake & Damper Options • Fresh air hood with bird screen • Fresh air hood with filters • 100mm disposable pleated filters (G4) • 100MM disposable pleated filters (F7) • Spare set of filters Control Options • Space temperature control with thermostat • Make-up air control sequence • Single zone variable air volume control • Duct static pressure control (VVT) • Remote exhaust fan start / stop • Space mounted CO2 sensor • • • • • • • • • • • Return air humidity sensor Smoke detector Main unit dirty filter pressure switch Thermal wheel dirty filter switch Phase loss / low voltage monitor LON DDC communication Bacnet modbus DDC communication Wall mounted remote monitoring display Hand held Convenience outlet Firestat Misc Options • 5 year additional warranty (compressor, gas or electric heating module) • 10 year additional warranty on gas available on the gas heater module • 2 years all parts warranty Exhaust Fan • 0 to 4.72 m3/s • High low fan speed control • Building static pressure control • Supply fan tracking • Adjustable constant volume control Optional Dehumidifcation Operation Model YDMA dedicated reheat system, provides stable and predictable year round performance. The independent circuit design allows superior part load efficiency without the hassle of low ambient control. The digital capacity control reliably maintains a stable 21° - 23°C discharge air temperature during the spring, summer and autumn months from the pre-cool DX coil and primary DX coils. The independent reheat circuit then applies reheat back into the airstream as needed. The table below shows actual unit performance during autumn and summer conditions. Reheat Performance Entering Air Conditions dP °C Hot summer day 28 / 20 17 31% Rainy autumn day 15 / 15 15 off Note: dry bulb and wet bulb temperatures show dewpoint. dP °C Reheat Pump COP 100% 22 / 15 11 20.4 100% 22 / 16 12 21.1 Reheat Capacity dB / wB Leaving Unit dB / wB DX Capacity .................................................................................................. Packaged Air Conditioning Unit .................................................................................................. Airflow and Damper Options AIR & DAMPER OPTION CODE Model AR1 YDMA ü AR4 YDHA YDSA Outside Air ü ü Option AR1 100% horizontal air opening, with no dampers or flanges AR7 AR8 AR25 AR2D AR2G AR2H AR2J AR2M AR2Y ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü Option AR4 Open bottom return air with 30% motorized outside air damper and small intake hood Outside Air Return Air Outside Air Option AR25 100% outside & return air openings with modulating (0-10v) OA & RA dampers plus spring return Option AR2D Outside Air 100% outside & exhaust air openings, motorized OA damper, spring return. Connection for power exhaust (power exhaust & damper must be ordered separately) 100% outside & return air openings with modulating (0-10v) OA & RA dampers, spring return and gravity relief exhaust damper Outside Air Exhaust & Return Air Outside Air Option AR2Y Outside Air 2-position OA damper with gravity damper exhaust Exhaust Air Exhaust Air Option AR2G Option AR8 100% outside air, horizontal opening with 2-position motorized OA damper, spring return Return Air Return Air Outside Air Outside Air Option AR7 100% vertical air opening No dampers or flanges ü Option AR2H 100% outside & return air openings with modulating (0-10v) OA & RA dampers, spring return plus conenction for power exhaust (power exhaust & damper must be ordered separately) Exhaust & Return Air Option AR2L 100% outside & exhaust air openings, motorized OA damper, spring return. Connection for energy recovery module Exhaust Air Outside Air Option AR2M 100% outside & return / exhaust air openings, motorized OA & RA dampers, spring return. Connection for energy recovery module Exhaust & Return Air .................................................................................................. Packaged Air Conditioning Unit .................................................................................................. YDMA TECHNICAL DATA Model Nominal capacity Nominal airflow Minimum Maximum 060 090 120 150 180 210 240 300 360 kW 17.6 26.4 35.2 44.0 52.8 61.5 70.3 87.9 105.5 m3/h m3/h 1100 2550 1650 2850 2200 5100 2750 5950 3400 7450 3850 8900 4400 9350 5800 12750 6650 15300 Compressor quantity Reheat capacity (Dehum) kW Gas heat size Non-condensing Condensing kW Electric heat size kW EER* 1 1 2 2 2 2 2 2 2 10 10 10 or 15 10 or 15 10 or 15 10 or 15 10 or 15 15 or 21 15 or 21 22 - 88 44 - 88 22 - 88 44 - 88 29 - 117 44 - 176 29 - 117 44 - 176 29 - 147 44 - 176 29 - 147 44 - 176 44 - 205 44 - 176 59 - 234 66 - 176 59 - 234 66 - 176 30 30, 60 3.85 3.54 3.85 3.71 30, 60, 90 4.05 30 / 60 / 90 / 120 3.55 Power 3.7 4.05 3.64 380-400v/3Ph/50Hz Note : Recommended Fuse size & Noise details are available on request. * At Eurovent conditions YDHA TECHNICAL DATA Model Nominal capacity Nominal airflow Minimum Maximum 060 090 120 150 180 210 240 300 360 kW 17.6 26.4 35.2 44.0 52.8 61.5 70.3 87.9 105.5 m3/h m3/h 1274 2854 2192 3823 2548 6031 3188 6031 3823 9344 4460 9344 5097 9344 6371 14781 7645 15885 Compressor quantity Reheat capacity (Dehum) kW Gas heat size Non-condensing Condensing kW Electric heat size kW EER* 1 1 2 2 2 2 2 2 2 10 10 10 or 15 10 or 15 10 or 15 10 or 15 10 or 15 15 or 21 15 or 21 22 - 88 44 - 88 22 - 88 44 - 88 29 - 117 44 - 176 29 - 117 44 - 176 29 - 147 44 - 176 29 - 147 44 - 176 44 - 205 44 - 176 59 - 234 66 - 176 59 - 234 66 - 176 3.33 3.52 3.52 30 30 / 60 / 90 3.47 3.52 3.73 Power 30 / 60 / 90 / 120 3.49 3.79 3.42 380-400v/3Ph/50Hz Note : Recommended Fuse size & Noise details are available on request. * At Eurovent conditions YDSA TECHNICAL DATA Model Nominal cooling capacity Nominal airflow Minimum Maximum 120 150 180 210 240 300 kW 35.2 44.0 52.8 61.5 70.3 87.9 m3/h m3/h 5946 8495 7433 9344 8919 12742 10406 14866 11893 16989 14866 19623 3.45 3.47 3.51 3.50 3.61 3.60 2 2 2 2 2 2 29 - 117 44 - 108 29 - 117 44 - 108 29 - 117 44 - 108 29 - 117 44 - 108 44 - 117 44 - 108 59 - 117 88 - 108 EER Compressor quantity Gas heat size Non-condensing Condensing kW Electric heat size kW Power Note : Recommended Fuse size & Noise details are available on request. 30 / 60 / 90 / 120 30 / 60 / 90 / 120 380-400v/3Ph/50Hz .................................................................................................. Packaged Air Conditioning Unit .................................................................................................. YDMA A D C M R L N O B D YDMA DIMENSIONS Model 060 090 120 150 180 210 240 300 360 A mm 2101 2101 2101 2101 2285 2285 2285 2569 2569 B mm 1347 1347 1601 1601 1689 1689 1689 2133 2133 C mm 3241 3241 3241 3241 3343 3343 3343 4105 4105 D mm 3264 3264 3264 3264 3366 3366 3366 4173 4173 L mm 594 594 594 594 1260 1260 1260 1514 1514 M mm 356 356 356 356 140 140 140 192 192 N mm 150 150 150 150 149 149 149 150 150 O mm 505 505 505 505 651 651 651 778 778 R mm 824 824 824 824 1024 1024 1024 1255 1255 .................................................................................................. Packaged Air Conditioning Unit .................................................................................................. YDHA A D C M R L N O B D YDHA DIMENSIONS Model 060 090 120 150 180 210 240 300 360 A mm 2101 2101 2101 2101 2285 2285 2285 2569 2569 B mm 1347 1601 1601 1601 1689 1689 1689 2133 2133 C mm 3241 3241 3241 3241 3343 3343 3343 4105 4105 D mm 3264 3264 3264 3264 3366 3366 3366 4173 4173 L mm 594 594 594 594 1260 1260 1260 1514 1514 M mm 356 356 356 356 140 140 140 192 192 N mm 150 150 150 150 149 149 149 150 150 O mm 505* 505* 505* 505* 651 651 651 778* 778* R mm 824 824 824 824 1024 1024 1024 1255 1255 Note : Unit weights available on request. * Except for option AR7 .................................................................................................. Packaged Air Conditioning Unit .................................................................................................. YDSA A D C M R L N B O D YDSA DIMENSIONS Model 120 150 180 210 240 300 A mm 2285 2285 2569 2569 2285 2569 B mm 1689 1689 2133 2133 1689 2133 C mm 3343 3343 4105 4105 3343 4105 D mm 3366 3366 4173 4173 3366 4173 L mm 1260 1260 1514 1514 1260 1514 M mm 140 140 192 192 140 192 N mm 149 149 150 150 149 150 O mm 651* 651* 778* 778* 651 778* R mm 1024 1024 1255 1255 1024 1255 * Except for option AR7 Document reference number: GB/REZ/037/1013 EN 2016-03 Nortek Global HVAC Belgium nv J&M Sabbestraat 130/A000 B-8930 Menen Belgium Tel. +32 (0)56 52 95 11 Fax. +32 (0)56 52 95 33 [email protected] www.reznor.eu Company Standards and Services: All products are tested and approved to CE standards. We are assessed to EN ISO 9001 Quality Assurance. We offer a service to our customers; including budget schemes, on site technical support and a comprehensive after-sales package. We reserve the right to change specifications without prior notice. Errors and omissions excepted.