Preview only show first 10 pages with watermark. For full document please download

Pafm3000 – Fm Broadcast Power Amplifier Alarm

   EMBED


Share

Transcript

PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL Designed for FM radio power amplifiers, this power amplifier alarm control have: General characteristics and features • Frequency range: 87.5-108Mhz, (Others frequency available). • • LCD Support: Yes, 24x2 (20x4, 40x2 or 40x4 optional). Alarms: FWD, RFL, Temperature and VDC. (FWD various modules, IDC Total, IDC various modules (1-4) and Fuse optionals). FWD Monitor Input: 0-0.7V or 0-1.4V. RFL/ROE/SWR Monitor Input: 0-0.7V. FWD Total: 0 to 9999W. (In request you select FWD alarm, 25 to 9999W). RFL Total: 0 to 199W. (In request you select RFL alarm, 1 to 199W). FWD Modules Monitor: Yes, 1 to 4 modules supported. VDC Monitor: Yes, optional. IDC Monitor: Yes, optional. IDC Monitor for RF Modules: Yes, 1 to 4, optional. Relay Support: Yes, 1 to 5, optional. Time Control: Optional. RS232 basic support: Yes, optional. Temperature sensor: Yes. Fuse protection board alarm: Yes. Fuse protection for RF modules: Yes, optional. Supply: 12VDC / 0.5A . Optional 48VDC / 0.1A. Board dimensions: 12.5 x 6.7 cm (4.9" x 2.6") . Operating Temperature: +5°C to 60°C. Non-Operating Temperature: -40° to +70°C. Electromagnetic Susceptibility: Designed to meet EN61000-4-2, -4-3, 4-4, -4-5 Level 3. • • • • • • • • • • • • • • • • • • • Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL FM Power Amplifier Alarm Control Models Document Version: 2.23 1A 1B 2A 2B 3A 3B 4A 4B PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL BOARDS ALARM TABLE GENERAL SPECIFICATIONS MODEL BOARD Supply Board Alarm (VDC) 1A 1B 2A 2B 3A 3B 4A 4B 12V 12V 12V 12V 12V 12V 12V 12V 48V (OPT) 48V (OPT) 48V (OPT) 48V (OPT) 48V (OPT) 48V (OPT) 48V (OPT) 48V (OPT) LCD 24x2 support LCD 40x2 support OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION LCD 20x4 support OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION LCD 40x4 support OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTION LCD Contrast ajust LCD Auto OFF backlight (5 minutes) Universal Front Panel support I2C Expansion support RS232 basic RS232 advanced PAFM3000 protocol Time Control Support FWD ALARM ON/OFF RFL/ROE/SWR ALARM ON/OFF TEMPERATURE ALARN ON/OFF VDC ALARM ON/OFF IDC ALARM ON/OFF FUSE ALARM ON/OFF FWD COUNT ALARM RFL/ROE/SWR COUNT ALARM TEMPERATURE COUNT ALARM VDC ALARM COUNT ALARM IDC ALARM COUNT ALARM Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL STARTED BOARD COUNT RF ON/OFF Led Alarm Led FWD Alarm Led RFL/ROE/SWR Alarm Led FWD Monitor Total Meter 1-9999W 1-9999W 1-9999W 1-9999W 1-9999W 1-9999W 1-9999W 1-9999W 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-0.7V 0.0-0.7V 0.0-0.7V 0.0-0.7V 0.0-0.7V 0.0-0.7V 0.0-0.7V 1-9999W 1-9999W 1-9999W 1-9999W 1-9999W 1-9999W 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V 1-9999W 1-9999W 1-9999W 1-9999W 1-9999W 1-9999W 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V 1-9999W 1-9999W 1-9999W 1-9999W 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V FWD Monitor Total VDC Input FWD Monitor Total TRIMMER ajust FWD Monitor Total Alarm RFL/ROE/SWR Monitor Total Meter RFL/ROE/SWR Total VDC Input RFL/ROE/SWR Monitor Total TRIMMER ajust RFL/ROE/SWR Monitor Total Alarm FWD Monitor Module 1 Meter FWD Monitor Module 1 VDC Input FWD Monitor Module 1 TRIMMER ajust FWD Monitor Module 2 Meter FWD Monitor Module 2 VDC Input FWD Monitor Module 2 TRIMMER ajust FWD Monitor Module 3 Meter FWD Monitor Module 3 VDC Input FWD Monitor Module 3 TRIMMER ajust Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL FWD Monitor Module 4 Meter FWD Monitor Module 4 VDC Input 1-9999W 1-9999W 0.0-0.7V 0.0-1.4V 0.0-0.7V 0.0-1.4V FWD Monitor Module 4 TRIMMER ajust Temp. Sensor Meter 0-99ºC 0-99ºC 0-99ºC 0-99ºC 0-99ºC 0-99ºC 0-99ºC 0-99ºC 60ºC 60ºC 60ºC 60ºC 60ºC 60ºC 60ºC 60ºC Temp. Sensor Alarm Relay Control General Relay Control for Module 1 Relay Control for Module 2 Relay Control for Module 3 Relay Control for Module 4 BOARD SUPPLY CONTROL SUPPORT Fuse protection Module 1 5-30A 5-30A 5-30A 5-30A 5-30A 5-30A 5-30A 5-30A 5-30A Fuse protection Module 1 Alarm Fuse protection Module 2 Fuse protection Module 2 Alarm Fuse protection Module 3 Fuse protection Module 3 Alarm Fuse protection Module 4 5-30A Fuse protection Module 4 Alarm VDC Monitor Total Meter 0.1-50V 0.1-50V 0.1-50V 0.1-50V 0.1-50V 0.1-50V 0.1-50V 0.1-50V 0.1-50V 0.1-50V 0.1-50V 0.1-50V 0.1-50V 0.1-50V VDC Monitor Total Alarm VDC Monitor Module 1 Meter Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL VDC Monitor Module 2 Meter 0.1-50V 0.1-50V 0.1-50V 0.1-50V 0.1-50V 0.1-50V 0.1-50V 0.1-50V 0.1-50V 0.1-50V 0.1-50V 0.1-50V VDC Monitor Module 3 Meter VDC Monitor Module 4 Meter IDC Monitor Total Meter 0.1-120A 0.1-120A 0.1-120A 0.1-120A 0.1-30.0A 0.1-30.0A 0.1-30.0A 0.1-30.0A 0.1-30.0A 0.1-30.0A 0.1-30.0A 0.1-30.0A 0.1-30.0A IDC Monitor Total Alarm IDC Monitor Module 1 Meter IDC Monitor Module 1 TRIMMER ajust IDC Monitor Module 1 Alarm IDC Monitor Module 2 Meter IDC Monitor Module 2 TRIMMER ajust IDC Monitor Module 2 Alarm IDC Monitor Module 3 Meter IDC Monitor Module 3 TRIMMER ajust IDC Monitor Module 3 Alarm IDC Monitor Module 4 Meter 0.1-30.0A IDC Monitor Module 4 TRIMMER ajust IDC Monitor Module 4 Alarm Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL ALARM BOARD - DIAGRAM AND CONNECTIONS (MODEL 1A) Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL ALARM BOARD - DIAGRAM AND CONNECTIONS (MODEL 2A) Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL ALARM BOARD - DIAGRAM AND CONNECTIONS (MODEL 3A) Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL ALARM BOARD - DIAGRAM AND CONNECTIONS (MODEL 4A) Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL ALARM BOARD - DIAGRAM AND CONNECTIONS (MODEL 1B) Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL ALARM BOARD - DIAGRAM AND CONNECTIONS (MODEL 2B) Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL ALARM BOARD - DIAGRAM AND CONNECTIONS (MODEL 3B) Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL ALARM BOARD - DIAGRAM AND CONNECTIONS (MODEL 4B) Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL ALARM BOARDS - CONNECTIONS DETAILS 1 – POWER SUPPLY ALARM BOARD CONNECTOR 1. GND 2. +12V (+48V Optional) 2 – FUSE ALARM BOARD - PCB solder 5A Fuse 3 – POWER SUPPLY JUMPER +48V (Only 1B/2B/3B/4B models) - Jumper for supply power alarm board with board VDC/IDC board sensor. ATTENTION: → Not supply alarm board in point 1 with jumper closed. (+12V or +48V). → Not supply alarm board with jumper closed and +12V in point 1 connected. → This option is only for alarm board with TL783 regulator installed in alarm board (Option). Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL 4 – RELAY CONTROL CONNECTOR - 10-pin header male connector Relay control. PIN FUNCTION PIN FUNCTION 1 +12V – 0.5A Max. current ----→ 2 GND 3 +12V – 0.5A Max. current ----→ 4 GND 5 +12V – 0.5A Max. current ----→ 6 GND 7 +12V – 0.5A Max. current ----→ 8 GND 9 +12V – 0.5A Max. current ----→ 10 GND - For you this option, you need Relay part with +12VDC support in coil and 0.5A max. Current. You can to use 1 to 5 relay for control Transmitter AC supply and amplifiers DC power supply. If you use power supply with ON/OFF logical control, you connect to PIN2, PIN4, PIN6, PIN8 or PIN10. Relay working in normal operation, then alarm board working and alarm is detected, relay is desactivated. 5 – LCD CONNTECTOR - 16-pin header male connector. LCD Led Blacklight. - 24X2, 40X2, 20X4 and 40X4 LCD supported. This feature is depend of software version. Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL 6 – FUSE SOCKET BOARD - VDC/IDC SENSOR (Only 1B/2B/3B/4B models) - Fuses sockets, 30A max. Supported by fuse socket (Only in 1B, 2B, 3B and 4B models) 7 - VDC/IDC SENSOR BOARD CONNECTOR INTERFACE (Only 1B/2B/3B/4B models) - 10-pin header male connector for VDC/IDC sensor board. - Connect to Alarm board in point 11. 8 – I2C INTERFACE CONNECTOR - 4-pin header male connector. PIN FUNCTION PIN FUNCTION 1 GND 2 +5V 3 SDA 4 SCL Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL 9 – RS232 CONNECTOR OR PAFM3000 EXTERNAL CONTROL 1 – GND 2 – RX / PAFM3000-1 3 – TX / PAFM3000-2 Note: This option working only with FM Transmitter 3000 or 3500 series. 10 – UNIVERSAL FRONT PANEL CONNECTOR - 10-pin header male connector. - Connect Universal Front panel in this connector with cable supplied. PIN FUNCTION PIN FUNCTION 1 LED ALARM 2 LED RF ON 3 DOWN BUTTON 4 SELECT/MENU BUTTON 5 UP BUTTON 6 GND 7 +5V 8 SCL 9 SDA 10 NC 11 - VDC/IDC SENSOR BOARD CONNECTOR INTERFACE (Only 1B/2B/3B/4B models) - 10-pin header male connector. - Connect to VDC/IDC SENSOR board in point 7 with cable supplied. Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL 12 – RF MONITOR SENSORS CONNECTOR - 14-pin header male connector for RF monitor coupler sensors in amplifiers boards PIN FUNCTION PIN FUNCTION 1 GND 2 FWD4 RF SENSOR (Only 4A/4B models) 3 GND 4 FWD3 RF SENSOR (Only 3A/3B/4A/4B models) 5 GND 6 FWD2 RF SENSOR (Only 2A/2B/3A/3B/4A/4B models) 7 GND 8 FWD1 RF SENSOR (Only 2A/2B/3A/3B/4A/4B models) 9 GND 10 RFL/ROE/SWR RF SENSOR 11 GND 12 FWDT RF SENSOR 13 GND 14 GND If you have 1B model, connect FWD coupler monitor sensor to 12 point. If you have 1B model, connect RFL/ROE/SWR coupler monitor sensor to 10 point. 13 – TEMPERATURE SENSOR CONNECTOR - DS18B20 - 16-pin header male connector for temperature sensors. PIN FUNCTION PIN FUNCTION 1,4,7,10,13,16 GND 2,5,8,11,14 DQ 3,6,9,12,15 +5V - Connect DS18B20 temperature sensor. For example: pin 1, 2 and 3. Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL UNIVERSAL FRONT PANEL UNIVERSAL FRONT PANEL - CONNECTOR - 10 pin header male connector. Connect with cable supplied to Alarm board. PIN FUNCTION PIN FUNCTION 1 LED ALARM 2 LED RF ON 3 DOWN BUTTON 4 SELECT/MENU BUTTON 5 UP BUTTON 6 GND 7 +5V 8 SCL 9 SDA 10 Not Connected UNIVERSAL FRONT PANEL – BUTTONS AND LEDS Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL EXAMPLE CONNECTIONS – MODEL 1A Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL EXAMPLE CONNECTIONS – MODEL 2A Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL EXAMPLE CONNECTIONS – MODEL 3A Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL EXAMPLE CONNECTIONS – MODEL 4A Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL EXAMPLE CONNECTIONS – MODEL 1B Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL EXAMPLE CONNECTIONS – MODEL 2B Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL EXAMPLE CONNECTIONS – MODEL 3B Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL EXAMPLE CONNECTIONS – MODEL 4B Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL LCD 24x2 Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL LCD 40x2 Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL LCD 20x4 Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL LCD 40x4 Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL LCD SOFTWARE MENU STARTING ALARM BOARD DIGITALION DPAFM3002 TECHNOLOGIES - DIGITALION DPAFM3002 TESTING RF SYSTEM POWER FM AMPLIFIER TECHNOLOGIES - 87.5-108 MHZ ###################### INSTALLED:1000W OK V.4.2.30-050613 MAIN MEASUREMENTS FWD:0000W STATUS: RFL: *** 00W WORKING T:25C V:48.0V I:00.3A *** Notes: - Read FWD, RFL, Temperature, VDC and IDC. - Green led RF ON in Universal Front panel is ON. - Status is WORKING in normal operation. If alarm in FWD, RFL, Temperature, VDC, IDC or Fuse, change to alarm text: STATUS: >> FWD FWD ALARM MODULE 1 ALARM << Notes: - If FWD is greater than the maximum FWD selected and FWD alarm is ON, skip this alarm. - Makes up to 10 retries, if the alarm persists, the alarm is blocked and an error message appears permanent. To remove this warning, you have to reset (OFF and ON) the alarm board. - Red led Alarm in Universal Front panel is ON. - Red led FWD Alarm in Universal Front panel is ON. STATUS: >>>>>> RFL ALARM RFL ALARM <<<<<<< Notes: - If RFL is greater than the maximum RFL selected and RFL alarm is ON, skip this alarm. - Makes up to 10 retries, if the alarm persists, the alarm is blocked and an error message appears permanent. To remove this warning, you have to reset (OFF and ON) the alarm board. - Red led Alarm in Universal Front panel is ON. - Red led RFL Alarm in Universal Front panel is ON. Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL STATUS: TEMPERATURE ALARM >>>>> TEMP. ALARM <<<<<< Notes: - If Temperature is greater than the maximum temperature selected and TEMP alarm is ON , skip this alarm. - Makes up to 10 retries, if the alarm persists, the alarm is blocked and an error message appears permanent. To remove this warning, you have to reset (OFF and ON) the alarm board. - Red led Alarm in Universal Front panel is ON. STATUS: >>>>>> VDC ALARM VDC ALARM <<<<<<< Notes: - If VDC is greater than the maximum VDC selected and VDC alarm is ON, skip this alarm. - Makes up to 1 retries, if the alarm persists, the alarm is blocked and an error message appears permanent. To remove this warning, you have to reset (OFF and ON) the alarm board. - Red led Alarm in Universal Front panel is ON. STATUS: >>>>>> IDC ALARM IDC ALARM <<<<<<< Notes: - If IDC is greater than the maximum IDC selected and IDC alarm is ON, skip this alarm. - Makes up to 1 retries, if the alarm persists, the alarm is blocked and an error message appears permanent. To remove this warning, you have to (OFF and ON) reset the alarm board. - Red led Alarm in Universal Front panel is ON. STATUS: >>>>>> FUSE ALARM FUSE ALARM <<<<< Notes: - If molten FUSE of 1B/2B/3B/4B board and FUSE alarm is ON, skip this alarm. - Makes up to 1 retries, if the alarm persists, the alarm is blocked and an error message appears permanent. To remove this warning, you have to (OFF and ON) reset the alarm board and you revise fuse state in VDC/IDC sensor board alarm. - Red led Alarm in Universal Front panel is ON. Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL MAIN MENU For you enter to Main Menu, you push Menu Button. The Main Menu have this options: - List of Alarms in board life. ############## >> Alarm List MAIN MENU ############### Status - Alarm limiter, you can change FWD, RFL, Temperature, VDC and IDC parameters for alarm limiter. ############## >> Alarm MAIN MENU ############### Limiter - Alarm configuration, you can to activate or not, FWD, RFL, Temperature, VDC, IDC and FUSE alarms. ############## >> Alarm MAIN MENU ############### Configuration - Remote Control for Transmitters 3000 and 3500 series by RS232 or PAFM3000 protocol. ############## >> Remote MAIN MENU ############### MENU ############### Control - Information alarm board, date and software version. ############## > DPAFM3002 MAIN Information - Restore alarm configuration to Factory values. ############## >> Factory by MAIN MENU ############### Default - Exit menu and return MAIN measurements. ############## >> Exit Document Version: 2.23 Menu MAIN MENU ############### PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL ALARM LIST STATUS In this menu option, you can to see alarms in board alarm life. The first parameter is alarms number in current status working and second parameter is acumulative in life board. If for example say FWD Count is 3 <> 023, this say 3 alarms have occurred since the alarm is ON and 23 is the cumulative total for the life of the alarm board. ########## >> FWD Count: ########## >> RFL TEMP VDC >> IDC <> 0 <> <> ALARM 0 ALARM Count: 0 ########## ALARM >> Count: STARTED ########## >> Return ALARM To ########### STATUS ########### STATUS ########### STATUS ########### STATUS ########### STATUS ########### 000 LIST <> STATUS 000 LIST <> ########### 000 LIST 0 STATUS 000 LIST ALARM Count: ########## LIST ALARM Count: ########## >> 0 Count: ########## >> ALARM 000 LIST 000 LIST Menu Notes: - Started Count is the number of ignitions (ON) of the alarm board. - For restart this values to 0 value, you OFF board Alarm, you push Menu button and ON alarm board, hold 5 seconds after reading the startup message. Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL ALARMS LIMITER - This menu option is for change values of alarms limiter in range supported in model. ############ >> FWDMAX: RFLMAX: TEMPMAX: VDCMAX: IDCMAX: ALARMS ALARMS ALARMS ALARMS >> Menu Document Version: 2.23 ############ LIMITER ############ LIMITER ############ LIMITER ############ LIMITER ############ 32.0A ############ Return LIMITER 50.0V ############ >> ALARMS 60C ############ >> ############ 060W ############ >> LIMITER 1100W ############ >> ALARMS To PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL ALARM CONFIGURATION This menu option is for ON or OFF individuals alarms. ######### >> FWD Alarm: ######### >> RFL TEMP >> VDC IDC >> FUSE ALARM ALARM ALARM ALARM ######### ALARM >> To Notes: ########## CONFIGURATION ########## ON CONFIGURATION ########## CONFIGURATION ########## ON Alarm: Return CONFIGURATION ON Alarm: ######### ########## ON Alarm: ######### >> ALARM Alarm: ######### CONFIGURATION ON Alarm: ######### >> ALARM CONFIGURATION ########## ON CONFIGURATION ########## Menu - Alarm menu can to change for differents models, 1A, 2A, 3A, 4A, 1B, 2B, 3B and 4B, and LCD used. - This LCD Menu example explication is for 40x2 LCD. Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL Document Version: 2.23 PAFM3000 – FM BROADCAST POWER AMPLIFIER ALARM CONTROL REVISION REVISION REVISION REVISION 2.2 - 05/2013 2.1 - 08/2012 2 - 10/2011 1 - 07/2011 Digit@lion Technologies reserves the right to make changes without further notice to any products herein. Digit@lion Technologies makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does Digit@lion Technologies assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation consequential or incidental damages. “Typical” parameters can and do vary in different applications. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. Digit@lion Technologies does not convey any license under its patent rights nor the rights of others. Digit@lion Technologies products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of the Digit@lion Technologies product could create a situation where personal injury or death may occur. Should Buyer purchase or use Digit@lion Technologies products for any such unintended or unauthorized application, Buyer shall indemnify and hold Digit@lion Technologies and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that Digit@lion Technologies was negligent regarding the design or manufacture of the part. Digit@lion Technologies and are registered trademarks of Digitalion Technologies. WARRANTY All OEM Aalarm boards have 1 year warranty in Digit@lion Technologies. The warranty not include the bad use of alarm boards. Shipping Cost to our laboratory and back for a repair is not included in the warranty. This product is manufactured by Digitalion Technologies. Made in Spain. For more information of others products you send e-mail to: [email protected] Document Version: 2.23