Transcript
LCR40 Resources
Page 1 of 2
LCR40 Reseller Resources Title
Atlas LCR - Passive Component Analyser (Model LCR40)
Catalogue copy Handheld LCR analyser providing measurements for inductance, capacitance and resistance. The component type is automatically detected for you, just connect and press "test". The te frequency is automatically selected to provide the best measurement resolution. Test frequencies include DC, 1kHz, 15kHz and 200kHz. Inductance from 1uH to 10uH, minimum resol of 1uH, typical accuracy of ±1.5% between 100uH and 100mH. Capacitance from 1pF to 10,000uF, minimum resolution of 1pF typical accuracy of ±1.5% between 200pF and 500nF. Resistance from 1R to 2MR, typical accuracy of ±1%. Test frequency is displayed with the measurement. Inductor DC resistance also displayed when testing inductors. Supplied with removable gold plated hook probes, battery and user guide. Compatible with standard 2mm test connectors. Not designed for in-circuit use. Key Features
Specification Summary
Automatic component type detection: Inductor, Capacitor or Resistor. Automatic test frequency selection: DC, 1kHz, 15kHz and 200kHz. Inductance from 1uH to 10H. Capacitance from 1pF to 10,000uF. Resistance from 1Ohm to 2MOhm. Inductance measurement also shows DC winding resistance. Test frequency displayed for all measurements. Typical accuracy of 1.5% for inductors and capacitors (see spec table for details). Typical accuracy of 1% for resistors. Test lead complete with gold plated 2mm plugs and sockets. Supplied with removable gold plated hook probes.
Parameters Minimum Typical Maximum range 1R 2MR Resistance resolution 0.3R 0.6R accuracy Typically ±1.0% ±1.2R range 0.5pF 10,000µF Capacitance resolution 0.2pF 0.5pF accuracy Typically ±1.5% ±1.0pF range 1µH 10H Inductance resolution 0.4µH 0.8µH accuracy Typically ±1.5% ±1.6µH Peak test voltage (across O/C) -1.05V +1.05V Peak test current (thru S/C) -3.25mA +3.25mA 1kHz -1.5% ±1% +1.5% Test 14.925kHz -1.5% ±1% +1.5% Frequency Accuracy 200kHz -1.5% ±1% +1.5% Sine Purity Typically -60dB 3rd harmonic Operating temperature range 10°C 40°C Battery type GP23A/MN21 12V Alkaline (supplied) Battery operating Voltage 8.5V 13V
Notes
1,2,6
1,2,5
1,2,4
3
Notes for table above: 1. Within 12 months of factory calibration. 2. Specified at temperatures between 15°C and 30°C. 3. Subject to acceptable LCD visibility. 4. For inductances between 100µH and 100mH. 5. For capacitances between 200pF and 500nF. 6. For resistances between 10Ω and 1MΩ.
Photography
Other Downloads
lcr40_userguide_en.pdf lcr40_datasheet_en.pdf
Dimensions per product 103 x 70 x 20 mm (excluding leads) Dimensions per product 200 x 138 x 30 mm (packaged) Weight per product (nett) Weight per product (packaged inc docs) Bulk order multiple
0.098kg
0.154kg
20, 80
Harmonisation /
http://www.peakelec.co.uk/resources/lcr40.html
24/04/2012
LCR40 Resources
Page 2 of 2
Commodity Code
9030 8999 GB
Fundamental Materials
Plastic, glass and metal.
Country of manufacture
England (UK)
Certification
CE, WEEE, ROHS
Keywords
peakelec, peak electronic design, peak electronics, peak electronic, Peak Atlas, Atlas, LCR40, Atlas LCR, LCR, LCR Bridge, LC Bridge, LC Meter, Passive component tester, Passive component analyser, Passive component analyzer, Passive component meter, inductor meter, inductance meter, inductor tester, capacitor meter, capacitance meter, capacitor tester, resis meter, resistance meter, resistor tester, component tester, component analyser, component analyzer, component identifier.
Suitable Accessories
SMD03M, CRC01M, PTPM, LCRLHP2, ATC55, ATC01, GP23A
Content available for re-use by express written permission only please. © Peak Electronic Design Limited. E&OE.
http://www.peakelec.co.uk/resources/lcr40.html
24/04/2012