Panamax Miw-mob For Installation With Miw Power Products.

   EMBED


Share

Transcript

Panamax MIW-MOB for installation with MIW POWER products. Bracket can be rotated for use new construction. Metal Outlet Boxes: Although specially designed for use with Max In-Wall products, the metal outlet boxes can also be used for standard receptacles and switches. Expansion clamp is used for retrofit. One box works in both new and retrofit construction projects. Features dual-size conduit knockouts (1/2” & 3/4”). 1/2 or 3/4 inch conduit knockout Installation Instructions when used with Panamax's MAX®IN-WALL™ (MIW) products. STEP 1: Select the mounting locations. The first box should be close to the head-end source equipment and the second box should be close to the display device. In the case of a plasma TV, it may be possible to position the outlet box behind the TV’s mounting location and hidden from view in the finished installation. In-wall conduit or power cable In-wall signal cables Second box Processor Breaker Panel First box Plasma TV, DLP, etc. Source equipment MIW POWER with Signal Line Protection Module MIW POWER with Signal Line Protection Module www.panamax.com INS0760 Rev. B 10/04 STEP 2: IMPORTANT - the conduit/cable entry must be on the opposite side of the box from the circuit board components or receptacle to provide the space required by code. Determine which way the MIW unit will be oriented when installed in the box then remove the box knockout opposite of where the circuit board components or receptacle will be. Example: If circuit board components are in up position, the conduit/cable entry must be from the bottom. STEP 3: Install the appropriate listed conduit/ armored cable coupler into the knockout hole before mounting the outlet box. STEP 4B: Circuit board components 4b. Retrofit (remodel/old construction) with MIW products – Using the included template as a guide, cut holes in the wall (one at each location identified in Step 1). Run the flexible conduit, AC power lines and signal-wires (not included) through one of the openings and route them through the walls to the location of the other box. MIW unit faceplate Conduit/cable entry Bracket can be rotated for use new construction. STEP 4A: Expansion clamp is used for retrofit. 1/2 or 3/4 inch conduit knockout New Construction - The expansion clamps are not used for new construction; remove them and reposition the brackets as shown above. Nail or screw the boxes to the wall studs, run conduit between the 2 locations and attach it to the boxes. Install the outlet box into one side of the hole, leaving the other side open for the signal-line side of the MIW unit. Tighten the expansion clamp screws until the box is held firmly in place. Be careful not to over-tighten the expansion clamps. Template for use with MIW POWER products 4 in. 3 3/4 in. 3 3/4 in. - Leave enough signal-line cable at each end to reach the source equipment and display device. Expansion clamp Template for use with standard switches and receptacles. 2 1/4 in. Be sure to: - Leave enough AC cabling at each end to connect to the MIW units. Three inches of wire should be able to extend beyond the opening of the outlet box. AC Power Side Signal Line Side STEP 4c Expansion clamp www.panamax.com INS0760 Rev. B 10/04