Panomera® S4 Commissioning
English
40 30
005029 / 1.0.3 / 2015-04-30
Information about Copyright, Trademarks, Design Patents © 2015 Dallmeier electronic The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design. We reserve the right to make technical modifications. The manufacturer accepts no liability for damage to property or pecuniary damages arising due to minor defects of the product or documentation, e.g. print or spelling errors, and for those not caused by intention or gross negligence of the manufacturer. Dallmeier electronic GmbH & Co.KG Cranachweg 1 93051 Regensburg Germany Tel.: +49 (0) 941 87 00-0 Fax: +49 (0) 941 87 00-180 www.dallmeier.com
[email protected]
All trademarks identified by ® are registered trademarks of Dallmeier electronic. All trademarks identified by *) are trademarks or registered trademarks of the following owners: JavaScript of Oracle Corporation (and/or its affiliates) headquartered in Redwood Shores, California, USA; Microsoft, ActiveX, DirectX, Internet Explorer, Windows and Windows Vista of Microsoft Corporation headquartered in Redmond, Washington, USA; NVIDIA und GeForce of NVIDIA Corporation headquartered in Santa Clara, California, USA; Third-party trademarks are named for information purposes only. Dallmeier electronic respects the intellectual property of third parties and always attempts to ensure the complete identification of third-party trademarks and indication of the respective holder of rights. In case that protected rights are not indicated separately, this circumstance is no reason to assume that the respective trademark is unprotected.
Panomera® S4
Table of Contents 1 Introduction 4 Validity4 Documents4 Typographical Conventions 5 2 Safety Instructions
6
3 General Notes 9 Scope of Delivery 9 Transportation and Packaging 9 Warranty9 Approvals/Certifications 9 Appropriate Use 10 Limits of the System 11 4 Requirements 12 General12 Voltage Supply 12 Maintenance13 5 Connectors
14
6 Installation
16
7 Connection and Login 18 System Requirements 18 Login19 Configuration Steps 20 8 Technical Specifications
21
9 Connection Assignment Power Supply Socket Network Socket
22 22 22
10 Dimensions
23
www.dallmeier.com
3
IntroductionPanomera® S4
1 Introduction Validity This document applies to the following device: • • • •
Panomera® S4 40/11 Baseline Panomera® S4 30/22 Baseline Panomera® S4 40/12 Topline Panomera® S4 30/24 Topline
Pictures in this document may differ from the actual device.
Documents Data Sheet The document “Data sheet” contains detailed technical specifications and features of the device. The target audience is trained system integrators. Installation Requirements The document „Installation Requirements“ contains the most important steps on the installation and calibration of a Panomera® Multifocal Sensor System. The target audience is trained system integrators. Commissioning The document “Commissioning” (this document) contains detailed descriptions on the installation, connection and commissioning of the device as well as safety instructions and general notes. The target audience is trained system integrators. Quick Guide The document “Quick Guide” contains the most important steps on the configuration of a Panomera® Multifocal Sensor System in connection with the software applications mentioned bilow. The target audience is trained system integrators. Observe the documentations on the Dallmeier software applications PService, SMAVIA Recording Server and SMAVIA Viewing Client.
4www.dallmeier.com
Panomera® S4
Introduction
Typographical Conventions This document may contain various warning words and symbols that indicate potential sources of danger: Danger DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. Warning WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. Caution CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. Notice NOTICE indicates practices for preventing property damage, incorrect configurations or faulty operations. For reasons of clarity and readability, various text formatting elements and types of emphasis are used in this documentation: Instructions are indicated by arrows: ¼¼Carry out instructions one after the other in the sequence described. Expressions in bold/italics generally indicate a control element on the unit (switches or labels) or on its user interface (buttons, menu items). Paragraphs in italics provide information on basic principles, special features and efficient procedure as well as general recommendations.
www.dallmeier.com
5
Safety InstructionsPanomera® S4
2 Safety Instructions Only use the unit if it is technically in proper working condition and for the intended purpose while keeping safety and potential dangers in mind.
Qualified Personnel
The installation, mounting, connection, commissioning and configuration of the unit may only be carried out by qualified personnel. This also applies to the maintenance, testing and repair, whereat the regulations of the DIN VDE 0701 series of standards (repair, modification and inspection of electrical appliances) must be followed.
Regulations
The use of video and audio surveillance systems is, in general, strictly regulated. Inform yourself about the currently valid laws and regulations regarding data, worker and environmental protection before using the unit and ensure compliance with them.
System Components
Only use internal components that have been tested and approved by Dallmeier. Inappropriate internal components may cause malfunctions, damages and data loss and may result in the loss of warranty.
Modifications
Do not make any modifications to the hardware or software that have not been tested and approved by Dallmeier. Inappropriate modifications may cause malfunctions, damages and data loss and may result in the loss of warranty.
Documentation
Read the documents included in the delivery carefully and thoroughly. Always observe the contained instructions, notes and warnings.
Condensation Water
If the unit is brought from a cold to a warm environment, resulting condensation water may cause malfunctions and damages. In this case, wait (up to 8 hours) until the unit has reached room temperature before commissioning.
6www.dallmeier.com
Panomera® S4
Safety Instructions
Earthing & Equipotential Bonding
For the safety of persons (protection against dangerous contact voltages) and devices (protection against overvoltages) and the immunity of information and communication technology equipment to electromagnetic interferences (EMI), all protective measures, which are specified by the currently valid DIN, VDE and ISO standards and which provide for a standard-compliant earthing and a correct equipotential bonding of electrical and electronic devices, are mandatory and must be fulfilled by all means.
Lightning Storms
To avoid damage to the unit by electrical surge during lightning storms, unplug the unit from the mains power supply (pull out the power plug). This is also recommended, when the unit has been unused for a long period of time.
Operating Conditions
Unfavourable operating conditions may shorten the life of the unit and may cause malfunctions, damages and data loss and may result in the loss of warranty. Observe the specifications given in the technical data, the operating condition requirements and the maintenance instructions.
Shocks
Shocks may cause malfunctions and damages. The unit may not be moved while in operation.
Foreign Bodies
If objects or liquids get into the unit, immediately disconnect it from the power supply (pull out the power plug). Contact the sales partner responsible for your area.
Burnt Smell
If you notice burnt smell or a formation of smoke coming from the unit, immediately disconnect it from the power supply (pull out the power plug). Contact the sales partner responsible for your area.
Opening
The housing of the unit may only be opened by qualified personnel for commissioning, inspection, maintenance and repair.
www.dallmeier.com
7
Safety InstructionsPanomera® S4
Disposal
Do not dispose waste electrical and electronic equipment into the household trash. Disconnect the unit from the power supply. Remove all connected devices. Return the unit to your respective sales partner.
8www.dallmeier.com
Panomera® S4
General Notes
3 General Notes Scope of Delivery The standard scope of delivery includes all cables that are necessary for a proper installation. However, it has to be considered that the scope of delivery may differ depending on the ordered equipment, the device variant or the country of destination.
Transportation and Packaging Store the original packaging for transportation at a later date. Dallmeier is not responsible for any damage resulting from unprofessional/improper transportation. The goods should only be shipped in their original packaging. If the original packaging is no longer available, ensure that the packaging used sufficiently protects the unit against damage, moisture, heat and cold.
Warranty The terms and conditions valid at the time the contract was signed shall apply.
Approvals/Certifications The following approvals/certifications were valid at the time of this document’s compilation: CE, FCC, ACA, DIN EN 50130-4 compliant Visit www.dallmeier.com for possible updates.
www.dallmeier.com
9
General NotesPanomera® S4
Appropriate Use The patented Panomera® Multifocal Sensor System is a totally novel camera technology particularly developed for the extensive video surveillance of largescale areas. With Panomera®, enormously broad ranges as well as areas with great distances are displayed in a completely new resolution quality – in real time and at high frame rates. With Panomera®, a huge area can be surveilled from a single location – and the resolution can be almost scaled without limits depending on the customer’s needs (e.g. by combining multiple Panomera® Multifocal Sensor Systems). The innovative lens and sensor concept of the Panomera® offers a unique overall view while, at the same time, capturing the finest of details even for long distances. The result is a significant reduction of infrastructural demands: In places where, in the past, several HD or megapixel cameras would have had been required, now, one Panomera® Multifocal Sensor System alone is sufficient. Panomera® far exceeds the conventional Full HD 1080p standard and megapixel resolution. As a Multifocal Sensor System especially scaled for each customer requirement, all areas of the entire surveillance scene are simultaneously displayed at maximum detail resolution. Regardless of which part of the surveilled area an operator concentrates on and no matter when, with Panomera® all events are entirely covered at all times. Therefore, an incident can always be re-constructed to be used as evidence in court, no matter where it took place and even at a later point in time, and individuals involved can be identified. Panomera® provides for a full overall view with minimum wear and almost no maintenance.
10www.dallmeier.com
Panomera® S4
General Notes
Limits of the System After installation, alignment and focusing of the device it is required to calibrate the module transitions. Please note that • a Panomera® Multifocal Sensor System is designed for a specific installation height and angle. Deviations can lead to faulty module transitions. • the recalibration of the module transitions is always required when the distance to the fixed scene objects (e.g. change of installation height and camera tilt) is changed. • prior to the calibration of the module transitions each camera module must be optimally focused. • the automatic calibration of the module transitions is not possible for lowcontrast scenes. In this case, place an object with sufficient contrast in the corresponding module area and restart the calibration. • areas with clearly differentiable scene content (clearly recognizable spatial structures, objects and textures) are preferred for the automatic calibration of the module transitions. • due to physical and optical properties, not all edge transitions can be corrected, since objects with different distances to the background do always have a different parallax offset. • due to diurnal and seasonal changes in humidity and temperature and thus the resulting component movements or material stresses (e.g. of poles and brackets) image changes may occur mainly in more distant scene areas (e.g. changes of image section and edge transitions).
www.dallmeier.com
11
RequirementsPanomera® S4
4 Requirements General The device is designed for indoor and outdoor operation. Unfavourable local conditions may shorten the life of the product and may cause malfunctions or damages. ¼¼Do not install/operate the device in places • • • • • • • •
with a large amount of dust and dirt, with steam or oil vapours, with direct sunlight, with strong heat emissions, with improper ambient temperatures, near sources with strong radiation (e.g. radio transmitters, magnetic fields), with corrosive surroundings (e.g. gases, salt water), with insufficient air ventilation (e.g. closed cabinet).
Environmental Conditions Suitable installation sites
Indoor/Outdoor
Operating temperature
−40 °C to +50 °C (minimum start-up temperature: −30 °C) Heater (activation): +15 °C ±3 °C Heater (deactivation): +22 °C ±3 °C
Relative humidity
0% – 90% RH, non-condensing
IP rating
IP66
Voltage Supply The device can be operated via Power over Ethernet (PoE+). ¼¼Ensure that the existing network supports the PoE standard IEEE 802.3at.
12www.dallmeier.com
Panomera® S4
Requirements
Maintenance The housing of the unit may only be opened by qualified personnel for commissioning, inspection, maintenance and repair.
Cleaning
If it is necessary to clean the device, observe the following notes: Notice Damage to the surface of the device ¼¼Clean the weather-proof housing (outside) with a soft, dry and antistatic cloth. Do not use detergents. ¼¼Clean the front glass of the weather-proof housing with water and some dishwashing agent using a soft, non-linting cloth or sponge. Avoid excessive rubbing..
www.dallmeier.com
13
ConnectorsPanomera® S4
5 Connectors The required connection cables are included in the scope of delivery (depending on the model).
❶
❷
❸ Fig. 1
❶ Power supply ❷ Pressure compensation element ❸ Network (cooper or fibre-optic) and PoE+ (depending on the model)
14www.dallmeier.com
Connectors
Panomera® S4
Electrical Data Voltage supply
Camera: 48 V DC or 24 V AC (50/60 Hz) or PoE+ (IEEE 802.3at) Heater: 24 V AC (50/60 Hz)
Power consumption
Camera: Max. 25.5 W Heater: Max. 20 W
Connections
M16 BULGIN circular plug-in connector Buccaneer PX0412/06P incl. adapter cable (length 5 m, UV resistant) with circular plug-in connector PX0410/06S on 4 single strands
Network Connections (depending on the model) Copper cabling
M16 BULGIN circular plug-in connector Buccaneer PX0412/10S incl. adapter cable (length 5 m, UV resistant) with circular plugin connector PX0410/10P on RJ45 plug, 100BASE-TX PoE+ (100 Mbps), 1000BASE-T PoE+ (1000 Mbps)
Fibre-optic cabling
www.dallmeier.com
SFP module (mini-GBIC) for 1000BASE-SX (MMF, 850 nm, 550 m) or 1000BASE-LX/LH (SMF, 1310 nm, 10 km)
15
InstallationPanomera® S4
6 Installation The installation and connection of the unit may only be carried out by qualified personnel.
❶
❷
Fig. 2
The housing is designed for the installation with two M6 screws (❶ and ❷) on a suitable bracket. A wall mount bracket with the following dimensions is offered optionally (item number 004389)
44 6
128 86 42
10
10 206 227
70 90
10 [mm]
Fig. 3
16www.dallmeier.com
Installation
Panomera® S4
Mechanical Data Construction material
Aluminium
Dimensions
See technical drawings
Finish
Powder coating, white
Weight
Max. 5.3 kg (w/o sun shield) Max. 5.8 kg (w/ sun shield)
Warning Falling device Danger of death or serious injury ¼¼Observe the manufacturer’s instructions about the maximum adequate carrying capacity of the supporting structure. ¼¼Use screws suitable for the wall material. ¼¼Use the correct type of anchor for your wall type: • Plastic screw anchors for solid wall material (concrete/brick) • Toggle bolt style anchors for drywall/hollow wall type (plaster)
www.dallmeier.com
17
Connection and LoginPanomera® S4
7 Connection and Login The configuration of a Panomera® Multifocal Sensor System is carried out with a PC via the local area network (LAN). The client PC must meet the following minimum system requirements for configuration and video display with SMAVIA Viewing Client.
System Requirements To configure the device with live video display, the PC must meet the following minimum system requirements: System Requirements Operating system (OS)
Microsoft*) Windows*) 7/8 Professional (64 Bit)
Processor (CPU)
3.6 GHz Quad-Core
Memory (RAM)
16 GB DDR3
Graphics Board
NVIDIA*) GeForce*) GTX 750
CUDA version CUDA cores PureVideo version Architecture
5.0 512 VP6 Maxwell
Network
1000 Mbps
Web browser
Microsoft Internet Explorer*) (latest version)
Software
JavaScript*) activated Microsoft ActiveX*) activated Dallmeier Live Video ActiveX (latest version)
Note that • the latest version of the Dallmeier Live Video ActiveX can automatically be downloaded from the internet after the connection to the device (Microsoft Internet Explorer and internet connection required).
18www.dallmeier.com
Panomera® S4
Connection and Login
• the latest version of the Dallmeier Live Video ActiveX can always be downloaded directly from the device without internet („Service“ > „Downloads“). Always install the latest version of the Dallmeier Live Video ActiveX after the connection to your Panomera® Multifocal Sensor System in order to benefit from the optimum performance of the system.
Login The factory default IP address of the Panomera® master module (overview module) is 192.168.2.31. ¼¼Ensure that the PC/web browser can establish a connection to the Panomera® Multifocal Sensor System via Ethernet. ¼¼Start the web browser. ¼¼Enter the IP address of the Panomera® Multifocal Sensor System (master module) into the address bar of the web browser. ¼¼Confirm the input. The connection to the Panomera® master module is established. The factory default administrator password of all Panomera® modules is 3. Notice Risk of misuse by unauthorized users! ¼¼Change the factory default admin password as soon as possible.
www.dallmeier.com
19
Connection and LoginPanomera® S4
Configuration Steps The configuration of a Panomera® Multifocal Sensor System in connection with systems for the recording (SMAVIA Recording Server) and evaluation (SMAVIA Viewing Client) is carried out in several steps: • Step 1: Network settings (PService) • Step 2: Focussing of the camera modules (Panomera® WebConfig) • Step 3: Automatic calibration (PService) • Step 4: Recording configuration (SMAVIA Recording Server) • Step 5: Displaying configuration (SMAVIA Viewing Client) ¼¼Observe the detailled descriptions in the documentation Quick Guide Panomera® Configuration.
20www.dallmeier.com
Technical Specifications
Panomera® S4
8 Technical Specifications The following basic technical specifications were valid at the time of this document’s compilation. Detailed specifications and possible updates can be found in the current product data sheet on www.dallmeier.com. Electrical Data Voltage supply
Camera: 48 V DC or 24 V AC (50/60 Hz) or PoE+ (IEEE 802.3at) Heater: 24 V AC (50/60 Hz)
Power consumption
Camera: Max. 25.5 W Heater: Max. 20 W
Connections
M16 BULGIN circular plug-in connector Buccaneer PX0412/06P incl. adapter cable (length 5 m, UV resistant) with circular plug-in connector PX0410/06S on 4 single strands
Network Connections (depending on the model) Copper cabling
M16 BULGIN circular plug-in connector Buccaneer PX0412/10S incl. adapter cable (length 5 m, UV resistant) with circular plugin connector PX0410/10P on RJ45 plug, 100BASE-TX PoE+ (100 Mbps), 1000BASE-T PoE+ (1000 Mbps)
Fibre-optic cabling
SFP module (mini-GBIC) for 1000BASE-SX (MMF, 850 nm, 550 m) or 1000BASE-LX/LH (SMF, 1310 nm, 10 km)
Mechanical Data Construction material
Aluminium
Dimensions
See technical drawings
Finish
Powder coating, white
Weight
Max. 5.3 kg (w/o sun shield) Max. 5.8 kg (w/ sun shield)
www.dallmeier.com
21
Connection AssignmentPanomera® S4
9 Connection Assignment Power Supply Socket ❻
❶
❺
❷
❹
❸ Abb. 4
Pin 1 2 3 4 5 6
Assignment 24 V AC / +48 V DC 24 V AC / −48 V DC 24 V AC -24 V AC --
Function Power camera Power camera Power heater None Power heater None
Color red black brown -orange --
Network Socket
❸
❷
❹ ❺
❶ ❽ ❿ ❼ ❻
❾ Abb. 5
Pin 1 2 3 4 5
Assignment D1 + D1 − D2 + D2 − D3 +
Color (TIA-568B) white/orange orange white/green green blue
Pin 6 7 8 9 10
Assignment D3 − D4 + D4 − Shield Shield
Color (TIA-568B) white/blue white/brown brown
22www.dallmeier.com
Dimensions
Panomera® S4
10 Dimensions
175 mm
141 mm
168 mm
153 mm
493 mm
Fig. 6
www.dallmeier.com
23