2. Local remote controller
G10 2nd
Functions
ON/OFF
HEAT
COOL
:Each unit
:Each group
:Each block
:Each floor
:Collective
:Not available
Operations Display
Description
Item
Controller
2-4. Wireless remote controller [PAR-FL32MA / PAR-FA32MA / PAR-SA9FA / PARSL94B-E]
ON/OFF
ON and OFF operation for a single group
Operation mode switching
Switches between Cool / Dry / Fan / Heat / Auto. Operation modes vary depending on the air conditioner unit. Auto only supported for the City Multi R2 and WR2 series.
Temperature setting
Sets the temperature for a single group Range of temperature setting Cool/Dry : 19°C - 30°C (14°C - 30°C) / 67°F - 87°F (57°F - 87°F) 17°C - 28°C (17°C - 28°C) / 63°F - 83°F (63°F - 83°F) Heat : Auto : 19°C - 28°C (17°C - 28°C) / 67°F - 83°F (63°F - 83°F) ( ) For PEFY/PFFY by setting DipSW 7-1 to ON and limits to NI6H fan speed only. Set to PAR-FL32MA according to its Installation Manual 4 "Model setting".
PAR-FL32MA
PAR-FA32MA (Signal receiving unit)
Fan speed setting
Air flow direction setting
Air flow direction angles (4-angle, Swing) Auto Louver ON/OFF. Air flow direction settings vary depending on the model.
Timer operation
One ON/OFF setting can be set for one day.
Permit / Prohibit local operation
PAR-SA9FA
PAR-SL94B-E
(4-way Cassette signal receiver)
(Wireless remote controller kit for ceiling suspended.)
Models with 4 air flow speed settings: Hi/Mid-1/Mid-2/Low Models with 3 air flow speed settings: Hi/Mid/Low Models with 2 air flow speed settings: Hi/Low Auto setting varies depending on the model.
Individually prohibit operation of each local remote control function (ON/OFF, Change operation mode, Set temperature, Reset filter). If operation is performed when the local remote controller inactivation command is received from the main system controller, a buzzer will ring and an LED will flash.
Indoor unit intake temperature
Measures the intake temperature of the indoor unit when the indoor unit is operating.
Error
When an error occurs on the air conditioner unit, the operation lamp on the signal receiving unit will flash.
It can operate in a group system without requiring address settings. When operating, it displays LED lamps. When errors occur, the error code can be shown by the LED flash count.
Test run
This operates air conditioner units in test run mode.
Ventilation equipment
Up to 16 indoor units can be connected to an interlocked system that has one LOSSNAY.
If an indoor unit with different functionality is operating inside the same group, please note there may be cases when functionality is partially disabled for batch control. Wireless remote controllers can only be used for a single refrigerant system. If you use a system controller to centrally control a group, you will need cross-wiring between indoor units when using a wireless remote controller. Also ensure there is no difference between the group setting of the main system controller and the cross wiring across indoor units when wiring and setting cross wires.
System example
1
Some models will have different display for the air flowdirection and fan speed. Set the air flow direction and fan speed when performing initial setting.
Wireless remote controller kit for ceiling suspended.
4-way Cassette signal receiver Non-polarized 2-wire
Signal receiving unit Wireless remote controller
Wireless remote controller
Wireless remote controller
External dimension PAR-FL32MA 58[2-9/32]
PAR-SA9FA
PAR-FA32MA
19[3/4] 22.5[7/8]
70[2-3/4]
19[ 3/4]
9.9[3/8]
3/ 4]
719
6[ ON/OFF
35.2[1-3/8] 83.5[3-9/32]
COOL
4.6 [3/16]
HEAT
120[4-23/32]
159[6-1/4]
TEMP
256[10- 1/8]
19[3/4]
NOT AVAILABLE
9.2[3/8]
PAR-SL94B-E
57 (2-1/4)
182 (7-3/16)
31 (1-1/4)
99 (3-15/16)
40 (1-5/8)
ON/OFF
4] 3/
AMPM
7-
°C AMPM
6[
CHECK TEST RUN MODEL SELECT
19
4.8[3/16]
Unit:mm[in.]
CONTROLLER