Parameter List For Vfs11 Ver108, 109

   EMBED


Share

Transcript

E6581304② VFS11 Parameter List for CPU version 108/109 Setting Date Customer End user Application Application No/Serial No Inverter’s Type-Form Quantity Inverter’s Serial No Motor’s capacity If user’s setting value is same as shipping value, entry column is blank. -Terminal stand use state Terminal Name Main terminal block PA/+ PB PC/PO R/L1 S/L2 T/L3 U/T1 V/T2 W/T3 E/G Control terminal block FLA FLB FLC RY RC CC VIA VIB PP FM F R RES S1 S2 S3 CC OUT NO P24 Setting of slide switch VIA FM SW1 Use state SOURCE 1 V V / / I / I PLC / SINK E6581304② 1 User parameters Title Function Unit  Operation frequency of operation panel Hz Minimum setting unit Adjustment range Panel/Communica Default setting User setting Reference tion 2 0.1/0.01 - 0.0 3.2 Basic parameters • Four automatic functions or basic parameters Minimum Title Communi cation No. Function Unit setting unit Panel/Commu Adjustment range Default User setting setting Reference nication  - History function - -  0000 Automatic acceleration/ deceleration - -  0001 Automatic torque boost - -  0040 Automatic function setting - - Command mode selection Frequency setting mode selection 1 - - - -  0003  0004 Displays parameters in groups of five in the reverse order to that in which their settings were changed. * (Possible to edit) 0: Disabled (manual) 1: Automatic 2: Automatic (only at acceleration) 0: Disabled 1: Automatic torque boost + auto-tuning 2: Vector control + auto-tuning 3: Energy saving + auto-tuning 0: Disabled 1: Coast stop 2: 3-wire operation 3: External input UP/DOWN setting 4: 4-20 mA current input operation 0: Terminal board 1: Operation panel 0: Built-in potentiometer 1: VIA 2: VIB 3: Operation panel 4: Serial communication 5: UP/DOWN from external contact 6: VIA + VIB (Override) 2 - 4.1.4 0 5.1.1 0 5.2 0 5.3 1 5.4 0 5.4 6.5.1 E6581304② Title Communic ation No.  0005  0006  0007  0008 Minimum Default User setting unit Function Unit Adjustment range Panel/Com setting setting munication 0 Meter selection 0:Output frequency 1:Output current 2:Set frequency 3:DC voltage 4:Output voltage command value 5:Input power 6:Output power 7:Torque 8:Torque current 9:Motor cumulative load factor 10:Inverter cumulative load factor 11:PBR (braking reactor) cumulative load factor 12:Frequency setting value (after PID) 13:VIA/II Input value 14:VIB Input value 15:Fixed output 1 (Output current: 100%) 16:Fixed output 2 (Output current: 50%) 17:Fixed output 3 (Other than the output current: 100%) 18:Serial communication data 19:For adjustments ( set value is displayed.) Meter adjustment 0 Default setting 0: 1: 50Hz default setting 2: 60Hz default setting 3: Default setting (Initialization) 4:Trip record clear 5:Cumulative operation time clear 6:Initialization of type information 7: Save user-defined parameters 8:Call user-defined parameters 9:Cumulative fan operation time record clears Forward/ 0: Forward run 0 reverse run 1: Reverse run selection 2: Forward run (Operation (F/R switching possible) panel) 3: Reverse run (F/R switching possible) 3 Reference 5.5 5.5 5.6 5.7 E6581304② Title Communic ation No.  0009  0010  0011  0012  0013  0014  0409  0015   0016 0600  0017 Function Acceleration time 1 Deceleration time 1 Maximum frequency Upper limit frequency Minimum setting unit Unit Adjustment range Panel/Com munication s 0.1/0.1 0.0-3200 Default User setting setting Reference 10.0 5.1.2 s 0.1/0.1 0.0-3200 10.0 5.1.2 Hz 0.1/0.01 30.0-500.0 80.0 5.8 Hz 0.1/0.01 0.5- 5.9 Lower limit frequency Base frequency 1 Hz 0.1/0.01 0.0- 50.0 (WP) 60.0 (WN, AN) 0.0 Hz 0.1/0.01 25-500.0 5.10 Base frequency voltage 1 V/F control mode selection 1 V 1/0.1 50.0 (WP) 60.0 (WN, AN) *3 − − % % (A) 0.1/0.1 1/1 - - Torque boost 1 Motor electronic-ther mal protection level 1 Electronicthermal protection characteristic selection *2 50-330 (200V class) 50-660 (400/600V class) 0: V/F constant 1: Variable torque 2: Automatic torque boost control 3: Vector control 4: Automatic energy-saving 5: Dynamic automatic energy-saving (for fans and pumps) 6: PM motor control 0.0-30.0 10-100 Set 0 1 2 3 4 5 6 7 OL protect on Standard on motor off off on on VF motor off off OL stall off on off on off on off on *1:Default values vary depending on the capacity. See the table of the last page *2:on:valid、off:invalid *3 : 230 (200V class), 460 (400V class), 575V (600V class) 4 5.9 5.10 6.13.6 2 5.11 *1 100 5.12 5.13 6.19.1 0 5.13 E6581304② Title Communic ation No.  0018  0019  0020  0021  0022  0023  0024  -  - Function Preset-speed operation frequency 1 Preset-speed operation frequency 2 Preset-speed operation frequency 3 Preset-speed operation frequency 4 Preset-speed operation frequency 5 Preset-speed operation frequency 6 Preset-speed operation frequency 7 Extended parameters Automatic edit function Minimum setting unit Unit Adjustment range Panel/Com munication Hz 0.1/0.01 - Default setting User setting Reference 5.14 0.0 Hz 0.1/0.01 - 0.0 Hz 0.1/0.01 - 0.0 Hz 0.1/0.01 - 0.0 Hz 0.1/0.01 - 0.0 Hz 0.1/0.01 - 0.0 Hz 0.1/0.01 - 0.0 - - - - - 4.1.2 - - - - - 4.1.3 5 E6581304② 3 Extended parameters • Input/output parameters Title Communicati on No.  0100  0101  0102  0105  0108  0109  0110  0111  0112  0113  0114  0115  0116  0117 Function Low-speed signal output frequency Speed reach setting frequency Speed reach detection band Priority selection (Both F-CC and R-CC are ON) Always-active function selection 1 Analog/contact input function selection (VIA/VIB terminal) Always-active function selection 2 Input terminal selection 1 (F) Input terminal selection 2 (R) Input terminal selection 3 (RES) Input terminal selection 4 (S1) Input terminal selection 5 (S2) Input terminal selection 6 (S3) Input terminal selection 7 (VIB) Minimum setting unit Unit Adjustment range Panel/Com munication Hz 0.1/0.01 0.0- Default User setting setting Reference 0.0 6.1.1 Hz 0.1/0.01 0.0- 0.0 6.1.3 Hz 0.1/0.01 0.0- 2.5 6.1.2 - - 0: Reverse 1: Slowdown Stop 1 6.2.1 - - 0-65 0 6.3.1 - - 0 6.2.2 - - 0: VIA - analog input VIB - analog input 1: VIA - analog input VIB - contact input (Sink) 2: VIA - analog input VIB - contact input (Source) 3: VIA - contact input (Sink) VIB - contact input (Sink) 4: VIA - contact input(Source) VIB - contact input (Source) 0-65 (ST) 1 6.3.1 - - 0-65 (F) 2 6.3.2 - - 0-65 (R) 3 - - 0-65 (RES) 10 - - 0-65 (SS1) 6 - - 0-65 (SS2) 7 - - 0-65 (SS3) 8 - - 5-17 (SS4) 9 6 E6581304② Title Communicati on No.  0118  0130  0131  0132  0137  0138  0139  0167  0170 Function Input terminal selection 8 (VIA) Output terminal selection 1A (RY-RC) Output terminal selection 2A (OUT-NO) Output terminal selection 3 (FL) Output terminal selection 1B (RY-RC) Output terminal selection 2B (OUT-NO) Output terminal logic selection (RY-RC, OUT-NO) Frequency command agreement detection range Base frequency 2 Minimum setting unit Unit Adjustment range Panel/Com munication 5-17 (AD2) Default User setting setting 5 6.3.2 6.3.3 - - 0-255 (LOW) 4 - - 0-255 (RCH) 6 - - 0-255 (FL) 10 - - 0-255 (always ON) 255 - - 0-255 (always ON) 255 - - Hz 0.1/0.01 0:  and   and  1:  or   and  2:  and   or  3:  or   or  0.0- Hz 0.1/0.01 25.0-500.0  0170 Base frequency Hz 1/0.1 50-330 (200V class) voltage 2 50-660 (400/600V class) 0172 Torque boost 2 % 0.1/0.1 0.0-30.0  Motor % 1/1 10-100  0173 electronic(A) thermal protection level 2 Stall prevention % 1/1 10-199  0185 level 2 (A) 200 (disabled) *1 : Default values vary depending on the capacity. See the table of last page *3 : 230 (200V class), 460 (400V class), 575 (600V class) 7 Reference 0 6.3.3 2.5 6.3.4 50.0 (WP) 60.0 (WN, AN) *3 6.4.1 *1 100 150 E6581304② • Frequency parameters Minimum Communicati Title on Function Unit No. setting unit Adjustment range Panel/Commu 0200 Frequency priority selection - -  0201 % 1/1  0202 Hz 0.1/0.01  0203 % 1/1  0204 VIA input point 1 setting VIA input point 1 frequency VIA input point 2 setting VIA input point 2 frequency Hz 0.1/0.01 0:  (Switchable to  by terminal input) 1:  (Switchable to  at less than 1.0Hz of designated frequency) 0-100 0.0-500.0  0210 VIB input point 1 setting VIB input point 1 frequency VIB input point 2 setting VIB input point 2 frequency % 1/1 Hz 0.1/0.01 % 1/1 Hz 0.1/0.01 0.0-500.0 Hz 0.1/0.01 Hz  0241  0242  0250  0251 6.5.2 100 - Starting frequency setting Operation starting frequency Operation starting frequency hysteresis DC braking starting frequency DC braking current 0 0-100 -  0240 6.5.1 0.0 Frequency setting mode selection 2  0213 0 0.0-500.0  0207  0212 Reference nication   0211 Default User setting setting 0: Built-in potentiometer 1: VIA 2: VIB 3: Operation panel 4: Serial communication 5: UP/DOWN from external contact 6: VIA + VIB (Override) 0-100 50.0 (WP) 60.0 (WN, AN) 1 6.5.1 0 6.5.2 0.0-500.0 0.0 0-100 100 0.5-10.0 50.0 (WP) 60.0 (WN, AN) 0.5 6.6.1 0.1/0.01 0.0- 0.0 6.6.2 Hz 0.1/0.01 0.0- 0.0 6.6.2 Hz 0.1/0.01 0.0- 0.0 6.7.1 %(A) 1/1 0-100 50 8 E6581304② Minimum Communicati Title on Function Unit No.  0252  0254  0256  0260  0261  0262  0264  0265  0266  0267  0268  0269  0270  0271  0272  0273 setting unit Panel/Commu Adjustment range Default User setting setting Reference nication DC braking time Motor shaft fixing control Time limit for lower-limit frequency operation Jog run frequency Jog run stopping pattern Panel jog run operation mode Input from external contacts – UP response time Input from external contacts – UP frequency step width Input from external contacts – DOWN response time Input from external contacts – DOWN frequency step width Initial value of UP/DOWN frequency Saving of changed value of UP/DOWN frequency Jump frequency 1 Jumping width 1 Jump frequency 2 Jumping width 2 s 0.1/0.1 - - s 0.1/0.1 Hz 0.1/0.01 - - - - s 0.0-20.0 0: Disabled 1: Enabled (after DC braking) 0: None 0.1-600.0 −20.0 1.0 6.7.1 0 6.7.2 0.0 6.8 5.0 6.9 0.1/0.1 0: Slowdown stop 1: Coast stop 2: DC braking 0: Disabled 1: Panel jog run operation mode enabled 0.0-10.0 0 0.1 Hz 0.1/0.01 0.0- 0.1 s 0.1/0.1 0.0-10.0 0.1 Hz 0.1/0.01 0.0- 0.1 Hz 0.1/0.01  0.0 − − Hz 0 0.1/0.01 0: Not changed 1: Setting of  changed when power is turned off 0.0- 0.0 Hz 0.1/0.01 0.0-30.0 0.0 Hz 0.1/0.01 0.0- 0.0 Hz 0.1/0.01 0.0-30.0 0.0 9 6.5.2 1 6.10 E6581304② Minimum Communicati Title on Function Unit No.  0274  0275  0287  0288  0289  0290  0291  0292  0293  0294 setting unit Adjustment range Panel/Commu Default User setting setting Reference nication Jump frequency 3 Jumping width 3 Preset-speed operation frequency 8 Hz 0.1/0.01 0.0- 0.0 Hz 0.1/0.01 0.0-30.0 0.0 Hz 0.1 - 0.0 Preset-speed operation frequency 9 Preset-speed operation frequency 10 Preset-speed operation frequency 11 Preset-speed operation frequency 12 Preset-speed operation frequency 13 Preset-speed operation frequency 14 Preset-speed operation frequency 15 (Fire-speed) Hz 0.1 - 0.0 Hz 0.1 - 0.0 Hz 0.1 - 0.0 Hz 0.1 - 0.0 Hz 0.1 - 0.0 Hz 0.1 - 0.0 Hz 0.1 - 0.0 6.10 5.14 6.11.2 • Operation mode parameters Minimum Communicati Title on Function Unit No.  0300  0301  0302 setting unit Adjustment range Panel/Commu Default User setting setting Reference nication PWM carrier frequency Auto-restart control selection kHz 0.1/0.01 - - Regenerative power ride-through control (Deceleration stop) - - 2.0 - 16.0 0: Disabled 1: At auto-restart after momentary stop 2: ST terminal on or off 3: At auto-restart or when turning ST-CC on or off 4: At start-up 0: Disabled 1: Automatic setting 2: Slowdown stop 10 12.0 6.12 0 6.13.1 0 6.13.2 E6581304② Minimum Communicati Title on Function Unit No. setting unit Adjustment range Panel/Commu Default User setting setting Reference nication  0303 Retry selection Times (number of times) Dynamic braking selection Over-voltage limit operation (Slowdown stop mode selection)  0304  0305  0307 Supply voltage correction (limitation of output voltage)  0308  0309  0311 Dynamic braking resistance Dynamic braking resistor capacity Reverse-run prohibition  0312    1/1 - - - - Ohm 0.1/0.1 kW 0: Disabled 1-10 0 6.13.3 0: Dynamic braking disabled 1: Dynamic braking enabled, overload protection enabled 0: Automatic setting 1: Disabled 2: Enabled (Quick deceleration) 3: Enabled (Dynamic quick deceleration) 0: Supply voltage uncorrected, output voltage limited 1: Supply voltage corrected, output voltage limited 2: Supply voltage uncorrected, output voltage unlimited 3: Supply voltage corrected, output voltage unlimited 1.0-1000 0 6.13.4 2 6.13.5 2 (WP, WN) 3 (AN) 6.13.6 *1 6.13.4 *1 6.13.4 0 6.13.7 0 6.12 1 6.12 0 10 6.14 6.14 0.01/0.01 0.01-30.00 - - Random mode - - 0316 Carrier frequency control mode selection - - 0320 0323 Drooping gain Drooping insensitive torque band % % 1/1 1/1 0:Forward/reverse run permitted 1:Reverse run prohibited 2:Forward run prohibited 0:Disabled 1:Automatic setting 0:Carrier frequency not reduced automatically 1:Carrier frequency reduced automatically 2:Carrier frequency not reduced automatically Support for 400V models 3:Carrier frequency reduced automatically Support for 400V models 0-100 0-100 *1 : Default values vary depending on the capacity. See the table of last page. 11 E6581304② Minimum Communicati Title on Function Unit No. setting unit Adjustment range Panel/Commu Default User setting setting nication 0342 Braking mode selection - -  0343 Release frequency Release time Creeping frequency Creeping time PID control waiting time PID control Proportional gain Hz 0.1/0.01 s Hz 0.01/0.01 0.00-2.50 0.1/0.01 -20.0 0.05 3.0 s s 0.01/0.01 0.00-2.50 1/1 0-2400 0.10 0 - 0: Disabled, 1: Enabled 0.01/0.01 0.01-100.0 0 0.30 - 0.01/0.01 0.01-100.0 0.01/0.01 0.00-2.55 0.20 0.00   0344  0345  0346  0359  0360  0362  0363  0366 Reference Integral gain Differential gain 0: Disabled 1: Enabled (forward run) 2: Enabled (reverse run) 3: Enabled (operating direction) -20.0 0 6.15 3.0 6.15 6.16 •Torque boost parameters Minimum Title Communicati on No. Function Unit setting unit Adjustment range Panel/Commu Default User setting setting Reference nication 0: Auto-tuning disabled 1: Initialization of  (reset to 0) 2: Auto-tuning enabled (after execution: 0) 0-150 50 0.1/0.1 0.0-30.0 *1 0.1/0.1 0.1-100.0 *1 1/1 10-90 *1 1/1 100-32000 - 1/1 1-150 1410 (WP) 1710 (WN, AN) 40 - 1/1 1-100 20  0400 Auto-tuning  0401  0402  0415  0416  0417 Slip frequency % gain Motor constant % #1 (primary resistance) Motor rated A current Motor no-load % current min-1 Motor rated speed  0418  0419 Speed control response coefficient Speed control stability coefficient - - 1/1 12 0 6.17 E6581304② • Input/output parameters2 Minimum Title Communicati on No. Function Unit VIA input bias VIA input gain VIB input bias VIB input gain - setting unit Adjustment range Panel/Commu Default User setting setting Reference nication     0470 0471 0472 0473 1/1 1/1 1/1 1/1 0-255 0-255 0-255 0-255 128 148 128 148 6.5.4 • Torque boost parameters2 Minimum Title Communicati on No. Function Unit setting unit Panel/Commu Adjustment range Default User setting setting Reference nication  0480 Exciting % 1/1 100-130 strengthening coefficient 0485 Stall 1/1 10-250  cooperation gain at field weakening zone 1 0492 Stall 1/1 50-150  cooperation gain at field weakening zone 2 Motor 1/1 0-200  0494 adjustment factor Maximum % 1/1 90-110  0495 voltage Adjustment coefficient Waveform kHz 0.1/0.1 0.1-14.0  0496 switching Adjustment coefficient *1 : Default values vary depending on the capacity. See the table of last page. 13 100 6.17 100 100 *1 104 - 0.2 - E6581304② • Acceleration/deceleration time parameters Minimum Title Communicati on No. Function Unit setting unit Adjustment range Panel/Commu Default User setting setting Reference nication  0500  0501  0502  0503  0504  0505  0506  0507  0510  0511  0512  0513 Acceleration time 2 Deceleration time 2 Acceleration/ deceleration 1 pattern Acceleration/ deceleration 2 pattern Acceleration/ deceleration selection (1, 2, 3) s 0.1/0.1 0.0-3200 10.0 s 0.1/0.1 0.0-3200 10.0 - - - - - - Acceleration/ deceleration 1 and 2 switching frequency S-pattern lower-limit adjustment amount S-pattern upper-limit adjustment amount Acceleration time 3 Deceleration time 3 Acceleration/ deceleration 3 pattern Acceleration/ deceleration 2 and 3 switching frequency Hz 0.1/0.01 % 0: Linear 1: S-pattern 1 2: S-pattern 2 6.18 0 0 1: Acceleration/deceleration 1 2: Acceleration/deceleration 2 3: Acceleration/deceleration 3 0.0- 0.0 1/1 0-50 10 % 1/1 0-50 10 s 0.1/0.1 0.0-3200 10.0 s 0.1/0.1 0.0-3200 10.0 - - Hz 0.1/0.01 0: Linear 1: S-pattern 1 2: S-pattern 2 0.0- 14 1 0 0.0 6.18 E6581304② • Protection parameters Minimum Title Communicati on No. Function Unit setting unit Adjustment range Panel/Commu Default User setting setting Reference nication  0601  0602  0603  0604  0605  0607  0608  0609  0610  0611  0612  0613 Stall prevention level 1 Inverter trip retention selection % (A) 1/1 - - Emergency stop selection - - Emergency DC braking time Output phase failure detection mode selection s 0.1/0.1 - - Motor 150%overload time limit Input phase failure detection mode selection Low current detection hysteresis Low current trip/alarm Small current detection current Small current detection time Detection of output short-circuit during start-up s 1/1 - - % 1/1 - - % 10-199, 200 (disabled) 150 6.19.2 0 6.19.3 0 6.19.4 1.0 6.19.4 0 6.19.5 300 6.19.1 0: Disabled, 1: Enabled 1 6.19.6 1-20 10 6.19.7 0 1/1 0: Alarm only 1: Tripping 0-100 0 s 1/1 0-255 0 - - 0: Each time(standard pulse) 1: At start-up (only one time after power is turned on) (standard pulse) 2: Each time (short-time pulse) 3: At start-up (only one time after power is turned on) (short-time pulse) 0 0:Canceled with the power off 1:Still retained with the power off 0:Coast stop 1:Slowdown stop 2:Emergency DC braking 0.0-20.0 0:Disabled 1:At start-up (only one time after power is turned on) 2:At start-up (each time) 3:During operation 4:At start-up + during operation 5:Detection of cutoff on output side 10-2400 15 6.19.8 E6581304② Minimum Title Communicati on No. Function Unit setting unit Adjustment range Panel/Commu Default User setting setting Reference nication  0615  0616  0618  0619  0621  0626  0627  0633  0634 Over-torque trip/alarm selection Over-torque % detection level Over-torque s detection time Over-torque % detection level hysteresis Cumulative 100 operation time Time alarm setting Over-voltage % stall protection level Under-voltage trip/alarm selection Trip at VIA low level input mode Annual average ambient temperature (calculation for life alarms) - 1/1 0.1/0.1 1/1 0.1/0.1 (=10 hours) 1/1 - % 1/1 - - 0: Alarm only 1: Tripping 0 6.19.9 0-250 150 0.0-10.0 0.5 0-100 10 6.19.9 0.0-999.9 610 6.19 .10 100-150 *1 6.13.5 0: Alarm only (detection level below 60%) 1: Tripping (detection level below 60%) 2: Alarm only (detection level below 50%, DC reactor necessary) 0: Disabled, 1-100 0 6.19 .12 0 6.19 .13 3 6.19 .14 1: -10 to +10 degree C 2: 11-20 degree C 3: 21-30 degree C 4: 31-40 degree C 5: 41-50 degree C 6: 51-60 degree C *1 : Default values vary depending on the capacity. See the table of last page. 16 E6581304② • Output parameters Minimum Title Communicati on No. Function Unit setting unit Adjustment range Panel/Commu Default User setting setting Reference nication  0669  0676  0677  0691  0692 Logic output/pulse train output selection (OUT-NO) Pulse train output function selection (OUT-NO) Maximum numbers of pulse train Inclination characteristic of analog output Meter bias - - 0: Logic output 1: Pulse train output 0 6.20.1 - - 0 6.20.1 pps 1/1 0:Output frequency 1:Output current 2:Set frequency 3:DC voltage 4:Output voltage command value 5:Input power 6:Output power 7:Torque 8:Torque current 9:Motor cumulative load factor 10:Inverter cumulative load factor 11:PBR (braking reactor) cumulative load factor 12:Frequency setting value (after PID) 13:VIA/II Input value 14:VIB Input value 15:Fixed output 1 (Output current: 100%) 16:Fixed output 2 (Output current: 50%) 17: Fixed output 3 (Other than the output current: 100%) 500-1600 800 6.20.1 - - 1 6.20.2 % 1/1 0 6.20.2 0: Negative inclination (downward slope) 1: Positive inclination (upward slope) 0−100 17 E6581304② • Operation panel parameters Minimum Title Communicati on No. Function Unit setting unit Adjustment range Panel/Commu Default User setting setting Reference nication  0700  0701  0702 Free unit selection  0705  0706  0707  0708  0710 Inclination characteristic of free unit display Free unit display bias Free step 1 (pressing a panel key once) Free step 2 (panel display) Standard monitor display selection  0719  0721  0730  0733 Prohibition of change of parameter settings Unit selection Canceling of operation command when standby terminal (ST) is turned off Panel stop pattern Prohibition of frequency setting on the operation panel () Panel operation prohibition (RUN/STOP keys) - - - - 0: Permitted 1: Prohibited 0:% 1:A (ampere)/V (volt) Times 0.01/0.01 0.00: Free unit display disabled (display of frequency) 0.01-200.0 0: Negative inclination (downward slope) 1: Positive inclination (upward slope) Hz 0.01/0.01 0.00- Hz 0.01/0.01 0.00: Disabled 0.01- - 1/1 - - - - - - - - - - 0: Disabled 1-255 0:Operation frequency (Hz/free unit) 1:Frequency command (Hz/free unit) 2:Output current (%/A) 3:Inverter rated current (A) 4:Inverter load factor (%) 5:Output power (%) 6:Frequency command after PID control (Hz/free unit) 7:Optional item specified from an external control unit 0:Operation command canceled (cleared) 1:Operation command retained 0: Slowdown stop 1: Coast stop 0: Permitted 1: Prohibited 0: Permitted 1: Prohibited 18 0 6.21.1 0 6.21.2 0.00 6.21.3 1 0.00 0.00 6.21.4 0 6.21.4 0 6.21.5 1 6.21.6 0 6.21.7 0 6.21.1 0 E6581304② Minimum Communicati Title on No. setting unit Adjustment range Default User setting setting Function Unit Prohibition of panel emergency stop operation Prohibition of panel reset operation Prohibition of change of  /  during operation - - 0: Permitted 1: Prohibited 0 - - 0: Permitted 1: Prohibited 0 - - 0: Permitted 1: Prohibited 1 Panel/Commu Reference nication  0734  0735  0736 • 6.21.1 Communication parameters Minimum Title Communicati Function Unit  0800 Communication band speed -  0801 Parity -   0802 0803 s  0805  0806 Inverter number Communication error trip time Communication waiting time Setting of master and slave inverters for communication between inverters (setting of master and slave) on No. setting unit Adjustment range Panel/Commu Default User setting setting Reference nication s - - 0: 1200bps 1: 2400bps 2: 4800bps 3: 9600bps 4: 19200bps 0: NON (No parity) 1: EVEN (Even parity) 2: ODD (Odd parity) 1/1 0-255 1/1 0: (disabled) 1-100 0.01/0.01 0.00-2.00 - 0: Slave inverter (0 Hz command issued in case the master inverter fails) 1: Slave inverter (Operation continued in case the master inverter fails) 2: Slave inverter (Emergency stop tripping in case the master inverter fails) 3: Master inverter (transmission of frequency commands) 4: Master inverter (transmission of output frequency signals) 19 3 1 0 0 0.00 0 6.22 E6581304② Minimum Title Communicati on No. Function Unit setting unit Adjustment range Panel/Commu Default User setting setting Reference nication   0811 0812   0813 0814  0829  0870  0871  0875  0876  0877  0878  0879 0880   0890  0891  0892  0893  0894 Point 1 setting Point 1 frequency Point 2 setting Point 2 frequency % Hz 1/1 0.1/0.01 0-100 0.0-500.0 0 0.0 % Hz 1/1 0.1/0.01 0-100 0.0-500.0 Selection of communication protocol Block write data 1 Block write data 2 - - 0: Toshiba inverter protocol 1: Modbus RTU protocol 100 50.0 (WP) 60.0 (WN, AN) 0 - - - - Block read data 1 Block read data 2 Block read data 3 Block read data 4 Block read data 5 - - - - - - - - - - Free notes Parameter for option 1 Parameter for option 2 Parameter for option 3 Parameter for option 4 Parameter for option 5 - 1/1 1/1 0: No selection 1: Command information 1 2: Command information 2 3: Frequency command 4: Output data on the terminal board 5: Analog output for communications 0: No selection 1: Status information 2: Output frequency 3: Output current 4: Output voltage 5: Alarm information 6: PID feedback value 7: Input terminal board monitor 8: Output terminal board monitor 9: VIA terminal board monitor 10: VIB terminal board monitor 0-65535 0-65535 - 1/1 0-65535 0 - 1/1 0-65535 0 - 1/1 0-65535 0 - 1/1 0-65535 0 20 6.5.2 6.22 0 0 0 0 0 0 0 0 0 6.23 E6581304② • Reservation area parameters Minimum setting Title Communication No. Function Unit unit Panel/Communi Adjustment range Default setting User setting Reference cation  0910  0911  0912 Step-out detection current level (for PM motors) Step-out detection time (for PM motors) Q axis inductance (for PM motors) % (A) 1/1 10-150 100 6.24 s 1/1 0.0: No detection 0.1-25.0 0.0 6.24 mH 0.01/0.01 0.00-650.00 0.00 - 21 E6581304② -Default settings by inverter rating Inverter type VFS11S-2002PL VFS11S-2004PL VFS11S-2007PL VFS11S-2015PL VFS11S-2022PL VFS11-2002PM VFS11-2004PM VFS11-2007PM VFS11-2015PM VFS11-2022PM VFS11-2037PM VFS11-2055PM VFS11-2075PM VFS11-2110PM VFS11-2150PM VFS11-4004PL VFS11-4007PL VFS11-4015PL VFS11-4022PL VFS11-4037PL VFS11-4055PL VFS11-4075PL VFS11-4110PL VFS11-4150PL Torque boost /  (%) 6.0 6.0 6.0 6.0 5.0 6.0 6.0 6.0 6.0 5.0 5.0 4.0 3.0 2.0 2.0 6.0 6.0 6.0 5.0 5.0 4.0 3.0 2.0 2.0  (Ohm) Dynamic braking resistor capacity  (kW) 200.0 200.0 200.0 75.0 75.0 200.0 200.0 200.0 75.0 75.0 40.0 20.0 15.0 10.0 7.5 200.0 200.0 200.0 200.0 160.0 80.0 60.0 40.0 30.0 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.12 0.24 0.44 0.66 0.88 0.12 0.12 0.12 0.12 0.12 0.24 0.44 0.66 0.88 Dynamic braking resistance Motor constant #1 Motor rated (primary current resistance)   (%) (A) 8.3 6.2 5.8 4.3 4.1 8.3 6.2 5.8 4.3 4.1 3.4 3.0 2.5 2.3 2.0 6.2 5.8 4.3 4.1 3.4 2.6 2.3 2.2 1.9 22 1.2 2.0 3.4 6.2 8.9 1.2 2.0 3.4 6.2 8.9 14.8 21.0 28.2 40.6 54.6 1.0 1.7 3.1 4.5 7.4 10.5 14.1 20.3 27.3 Motor no-load current  (%) 70 65 60 55 52 70 65 60 55 52 48 46 43 41 38 65 60 55 52 48 46 43 41 38 Over Motor voltage stall adjustment protection factor level   (%) 90 90 80 70 70 90 90 80 70 70 70 70 70 60 50 90 80 70 70 70 70 70 60 50 134 134 134 134 134 134 134 134 134 134 134 134 134 134 134 140 140 140 140 140 140 140 140 140