Transcript
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
September 2010
Revision History Version and Date September 2010
Description of Changes Added information for the LSISAS9202-16e host adapter board.
April 2010
Added information for the LSISAS9201-16i., and LSISAS9201-16e host adapter boards.
March 2010
Updated Figure 2, LSISAS9200-8e Board Layout, on page 15, Figure 3, LSISAS9210-8i Board Layout, on page 17, Figure 4, LSISAS9211-8i Board Layout, on page 19, Figure 5, LSISAS9211-4i Board Layout, on page 21, Figure 6, LSISAS9212-4i4e Board Layout, on page 23, and Figure 7, LSISAS9200-16e Board Layout, on page 25.
October 2009
Added information for the LSISAS9212-4i4e and the LSISAS9200-16e host adapter boards.
July 2009
Initial release of this document.
LSI, the LSI logo, MegaRAID, and Fusion-MPT are trademarks or registered trademarks of LSI Corporation or its subsidiaries. All other brand and product names may be trademarks of their respective companies. Windows is a registered trademark of Microsoft Corporation. Linux is the registered trademark of Linus Torvalds in the U.S. and other countries. Solaris is a trademark of Sun Microsystems, Inc. Red Hat and Enterprise Linux are registered trademarks of Red Hat, Inc. SUSE is a registered trademark of Novell, Inc. SPARC is a registered trademark of SPARC International, Inc. LSI Corporation reserves the right to make changes to the product(s) or information disclosed herein at any time without notice. LSI Corporation does not assume any responsibility or liability arising out of the application or use of any product or service described herein, except as expressly agreed to in writing by LSI Corporation; nor does the purchase, lease, or use of a product or service from LSI Corporation convey a license under any patent rights, copyrights, trademark rights, or any other of the intellectual property rights of LSI Corporation or of third parties. This document contains proprietary information of LSI Corporation. The information contained herein is not to be used by or disclosed to third parties without the express written permission of LSI Corporation. Corporate Headquarters Milpitas, CA 800-372-2447 Document Number: DB15-000556-05 Copyright © 2010 LSI Corporation All Rights Reserved
Email
[email protected]
Website www.lsi.com
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
Table of Contents
Table of Contents Chapter 1: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 1.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 1.2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 1.3 PCI Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 1.4 Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Chapter 2: Hardware Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 2.1 Quick Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 2.2 Detailed Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Chapter 3: Host Bus Adapter Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 3.1 Characteristics of the LSI PCIe to SAS HBAs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 3.1.1 LSISAS9200-8e HBA Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 3.1.2 LSISAS9210-8i HBA Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 3.1.3 LSISAS9211-8i HBA Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 3.1.4 LSISAS9211-4i HBA Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 3.1.5 LSISAS9212-4i4e HBA Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 3.1.6 LSISAS9200-16e HBA Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 3.1.7 LSISAS9201-16i HBA Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 3.1.8 LSISAS9201-16e HBA Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 3.1.9 LSISAS9202-16e HBA Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 3.2 Electrical and Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 3.2.1 Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 3.2.2 Thermal and Atmospheric Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 3.2.3 Safety Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
LSI Corporation Confidential | September 2010
Page 3
Table of Contents
Page 4
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
LSI Corporation Confidential | September 2010
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
Chapter 1: Introduction | Overview
Chapter 1 Introduction This chapter describes the LSI PCI Express to 6Gb/s Serial Attached SCSI host bus adapters. 1.1
Overview
The LSI PCI Express (PCIe) to Serial Attached SCSI (SAS) host bus adapters (HBAs) provide four, eight, or sixteen serial ports for connection to SAS and Serial ATA (SATA) devices. Each port is capable of 1.5Gb/s, 3Gb/s, and 6Gb/s link rates for both SAS and SATA. The PCIe transmission and reception data rate is 5Gb/s in each direction, yielding a total bandwidth of 10Gb/s for each full-duplex lane. The LSI PCIe to SAS HBAs use four, eight, or sixteen PCIe phys, which provide possible host-side maximum transmission and reception rates of up to 8GB/s for the LSISAS9202-16e HBA (x16 interface). The design of the LSI HBAs makes it easy to add SAS interfaces to any computer, workstation, or server that has a PCIe bus. The LSISAS9211-4i, LSISAS9210-8i, LSISAS9211-8i, LSISAS9200-8e, LSISAS9212-4i4e, LSISAS9200-16e, LSISAS9201-16e, LSISAS9201-16i, and LSISAS9202-16e HBAs include Flash ROM for storing the BIOS and firmware, and NVSRAM for storing nonvolatile RAID information. The LEDs on the HBAs report a heartbeat. Fusion-MPT™ firmware operates the HBA. The PCIe interface is compliant with the PCI Express Specification, revision 2.0. All PCI software is backward compliant with previous versions of the PCI/PCI-X specifications. The LSI PCIe to SAS HBAs use either a standard PCI bracket or a low-profile, PCI-bracket type. The interface of the LSI HBAs is compatible with the ANSI Serial Attached SCSI Specification, revision 2.0 and the Serial ATA Specification, revision 2.6. The PCIe and SAS functionality of LSI PCIe to SAS HBAs is provided by one of the following LSI controller chips:
The LSISAS2004 controller chip, which integrates four high-performance SAS/SATA phys and connects up to four SAS/SATA devices to a computer system through the PCIe interface.
The LSISAS2008 controller chip, which integrates eight high-performance SAS/SATA phys and connects up to eight SAS/SATA devices to a computer system through the PCIe interface.
The LSISAS2116 controller chip, which integrates sixteen high-performance SAS/SATA phys and connects up to sixteen SAS/SATA devices to a computer system through the PCIe interface.
The controller chip on each HBA connects directly to the PCIe bus and generates timing and protocol in compliance with the PCIe specification. The controller chips connect channels directly to the SAS and SATA devices in the computer system. As described in Chapter 3, Host Bus Adapter Characteristics, the LSI controllers use either a x4, x8, or x16 PCIe connector.
LSI Corporation Confidential | September 2010
Page 5
Chapter 1: Introduction | Features
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
The following table shows which LSI controllers is used for each model of LSI PCIe to SAS HBA. Table 1:
LSI Controllers and Associated LSI PCIe to SAS HBAs
Controller LSISAS2004
LSISAS9211-4i
LSISAS2008
LSISAS9210-8i, LSISAS9211-8i, LSISAS9200-8e, LSISAS9212-4i4e, and LSISAS9202-16e1
LSISAS2116
LSISAS9200-16e, LSISAS9201-16e, and LSISAS9201-16i
1.
1.2
Features
LSI PCIe to SAS HBA Model
The LSISAS9202-16e HBA uses two LSISAS2008 controller chips.
This section lists the features of the LSI PCIe to SAS HBAs:
Supports serial SCSI protocol (SSP), serial ATA tunneling protocol (STP), and serial management protocol (SMP), as defined, in the Serial Attached SCSI (SAS) Specification, version 2.0.
Supports SATA, as defined in the Serial ATA Specification, version 2.6.
Provides configurable drive spin-up sequencing on a per-phy basis.
Simplifies cabling with a point-to-point, serial architecture.
Provides smaller and thinner cables that promote unrestricted airflow.
Provides a serial, point-to-point, enterprise-level storage interface.
Transfers data using SCSI information units.
Provides compatibility with SATA target devices.
Supports narrow ports and wide ports, as described in the following table.
Table 2:
6Gb/s SAS Bandwidths Half Duplex
Page 6
Full Duplex
Narrow Port (1 Lane), 600 MB/s
Narrow Port (1 Lane), 1200 MB/s
Wide Port (2 Lanes), 1200 MB/s
Wide Port (2 Lanes), 2400 MB/s
Wide Port (4 Lanes), 2400 MB/s
Wide Port (4 Lanes), 4800 MB/s
LSI Corporation Confidential | September 2010
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
1.3
PCI Performance
Chapter 1: Introduction | PCI Performance
The LSI PCIe to SAS HBAs support the following features of the PCIe interface.
A single-phy (one lane) link transfer rate up to 5Gb/s in each direction
Link widths of x16, x8, x4, and x1
Automatic downshift. The LSISAS9202-16e HBA automatically downshifts to a x8-link width if plugged into a x16 connector that is wired as a x8 or x12 connector. Other HBA models automatically downshift to a x4-link if plugged into a x8 connector that is wired as a x4 connector.
A scalable interface — — — —
Single-lane aggregate bandwidth of up to 0.5GB/s (500MB/s) Quad-lane aggregate bandwidth of up to 2GB/s (2000MB/s) Eight-lane aggregate bandwidth of up to 4GB/s (4000MB/s) Sixteen-lane aggregate bandwidth of up to 8GB/s (8000MB/s)
Serial, point-to-point interconnections between devices — Reduces the electrical load of the connection — Enables higher transmission and reception frequencies
Lane reversal and polarity inversion
PCIe hot plug
Power management — Supports PCI Power Management 1.2 — Supports active-state power management (ASPM), including the L0, L0s, and L1 states, by placing links in a power-saving mode when there is no link activity
A replay buffer that preserves a copy of the data for retransmission in case a cyclic redundancy check (CRC) error occurs
PCIe advanced error-reporting capabilities
Packetized and layered architecture
High bandwidth per pin with low overhead and low latency
Software compatibility with PCI and PCI-X software — Leverages existing PCI device drivers — Supports the memory, I/O, and configuration address spaces — Supports memory read/write transactions, I/O read/write transactions, and configuration read/write transactions
LSI Corporation Confidential | September 2010
4 KB of PCI configuration address space per device
Posted and nonposted transactions
Quality-of-service (QOS) link configuration and arbitration policies
Traffic Class 0 and one virtual channel
Message-signaled interrupts (both MSI and MSI-X), as well as INTx interrupt signaling for legacy PCI support
End-to-end CRC (ECRC) and advanced error reporting
Page 7
Chapter 1: Introduction | Software
1.4
Software
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
The following table shows all of the major operating systems that the LSI PCIe to SAS HBAs support. Table 3:
Operating System (OS) Drivers OS Support
Versions
Windows®
Server 2003/2008, XP/Vista/Windows 7
Linux®: Red Hat® Enterprise Linux® (RHEL)
4 and 5
Linux: SUSE® Enterprise Server (SLES)
9, 10, and 11
Sun™ SPARC® Solaris™
Solaris 10
Utilities
Flash and BIOS Configuration Utility
The LSI HBAs use the Fusion-MPT architecture for all major operating systems, which allows for thinner drivers for better performance. To obtain a device driver that supports your operating system, contact the LSI Technical Support team or visit the LSI website.
Page 8
LSI Corporation Confidential | September 2010
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
Chapter 2: Hardware Installation | Quick Installation Instructions
Chapter 2 Hardware Installation This chapter provides both quick instructions and detailed instructions on how to install the LSI PCIe to 6Gb/s SAS HBAs. 2.1 Quick Installation Instructions
Use the following quick installation instructions to install your LSI PCIe to SAS HBA if you are comfortable with the abbreviated installation instructions. Section 2.2, Detailed Installation Instructions provides detailed installation instructions. 1. Unpack the HBA and inspect it for damage. 2. Turn off the system and remove the power cord(s). 3. Remove the cover from the system. 4. Insert the HBA in an available PCIe slot. 5. Secure the bracket to the system’s chassis. 6. Connect the serial cable(s) between the HBA and the serial hard disk drive(s). Figure 1 shows the locations of the connectors on your HBA. 7. Replace the cover and the power cord(s), then turn on the system. The installation of your LSI HBA is complete.
LSI Corporation Confidential | September 2010
Page 9
Chapter 2: Hardware Installation | Detailed Installation Instructions
2.2 Detailed Installation Instructions
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
The following are the detailed installation instructions for LSI PCIe to SAS HBAs. 1. Unpack the HBA and inspect it for damage. Unpack the HBA in a static-free environment. Remove the HBA from the antistatic bag and carefully inspect it for damage. If you notice any damage, or if any component is missing, contact LSI or your reseller support representative.
CAUTION
CAUTION: Make a backup of your data before changing your system configuration.
2. Prepare the computer. Turn off the computer and disconnect the power cord from the back of the power supply. Remove the cover from the chassis. WARNING: Be certain to disconnect the computer from the power supply and from any networks before installing the HBA. 3. Insert the HBA in an available PCIe slot. Locate an empty PCIe slot. Remove the blank bracket panel on the back of the computer that aligns with the empty PCIe slot. Save the bracket screw, if applicable. Align the HBA to a PCIe slot. Press down gently but firmly to properly seat the HBA in the slot. The following figure shows how to insert the HBA in a PCIe slot.
Page 10
LSI Corporation Confidential | September 2010
Chapter 2: Hardware Installation | Detailed Installation Instructions
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
HDD Connector
Bracket Screw
Press Here
Serial Signal Cables Mini-SAS x4 (SFF-8087) to SAS x1 Internal Fan-Out Cable
Press Here
SFF-8088 Mini-SAS Cable and Connector
Two mini-SAS x4 Connectors
32-bit Slots (3.3 V) Edge of Host Board
Figure 1:
PCIe x8 Slot 64-bit Slots (3.3 V)
Installing an LSI PCIe to SAS x8 HBA in a PCI Express Slot
NOTE: The shape, size, and locations of components on your HBA and its bracket might vary from this illustration. The LSISAS9202-16e HBA requires a x16 PCIe slot. The LSISAS9211-4i HBA requires a x4 PCIe slot. The LSISAS9211-4i HBA can be up-plugged into a x8 slot or a x16 slot. 4. Secure the bracket to the system’s chassis. Install the bracket screw, if applicable, or engage the system retention mechanism to secure the HBA to the system’s chassis. 5. Connect the serial cable(s) between the HBA and the serial hard disk drive(s) (HDD). Connect the serial cable(s) between the host adapter and the serial hard disk drive(s) (HDD). Figure 1 shows the locations of the connectors on your HBA. 6. Replace the cover and the power cord(s) and power up the system. Replace the system’s cover, reconnect the power cord(s), and reconnect any network cables. Turn on the power. The installation of your LSI PCIe to SAS HBA is complete.
LSI Corporation Confidential | September 2010
Page 11
Chapter 2: Hardware Installation | Detailed Installation Instructions
Page 12
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
LSI Corporation Confidential | September 2010
Chapter 3: Host Bus Adapter Characteristics | Characteristics of the LSI PCIe to SAS HBAs
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
Chapter 3 Host Bus Adapter Characteristics This chapter describes the device-specific characteristics of the LSI PCIe to 6Gb/s SAS HBAs. 3.1 Characteristics of the LSI PCIe to SAS HBAs
The LSI PCIe to SAS HBAs provide one or two 4M x 8-bit Flash ROMs for storing the BIOS and firmware. The following table shows the number and type of x4 external and internal SAS connectors provided on each HBA model and also the number of external LED headers. Table 4:
HBA Connector Summary
HBA Model
Internal Connectors
External Connectors
External LED Headers
LSISAS9200-8ea
—
2 x4 mini SAS
1 - 4pin header
LSISAS9210-8ia.
2 x4 mini SAS
—
1 - 4pin header
LSISAS9211-8ia.
2 x4 mini SAS
—
1 - 4pin header
LSISAS9211-4ia.
1 x4 mini SAS
—
1 - 4pin header
LSISAS9212-4i4ea.
4 x1 mini SAS
1 x4 mini SAS
1 - 4pin header
LSISAS9200-16e
—
4 x4 mini SAS
2 - 4pin headers
LSISAS9201-16i
4 x4 mini SAS
—
2 - 4pin headers
LSISAS9201-16e
—
4 x4 mini SAS
2 - 4pin headers
LSISAS9202-16ea.
—
4 x4 mini SAS HD
—
a.
Low-profile HBA.
The LSISAS9210-8i, LSISAS9211-8i, LSISAS9211-4i, and LSISAS9212-4i4e HBAs may provide up to 32 K x 8-bit NVSRAM for storing the nonvolatile RAID information when a system failure occurs.
LSI Corporation Confidential | September 2010
Page 13
Chapter 3: Host Bus Adapter Characteristics | Characteristics of the LSI PCIe to SAS HBAs
3.1.1 LSISAS9200-8e HBA Characteristics
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
The LSISAS9200-8e HBA has onboard Flash ROM for firmware and BIOS. The LSISAS2008 controller brings 6Gb/s SAS performance to HBA, workstation, and server designs, making it easy to add a SAS interface to any PCIe system. Each of the eight SAS phys on the LSISAS2008 controller is capable of up to 6Gb/s SAS or SATA link rates.
3.1.1.1
LEDs
The LSISAS9200-8e HBA has a 4-pin header for connection of activity LEDs. The 4-pin header connects to two LEDs (see Table 5), which indicate SAS activity on Port 0 and Port 1.
3.1.1.2
Connectors
This section describes the different connectors on the LSISAS9200-8e HBA. See Figure 2 for connector locations. PCIe Connector (J7). The LSISAS9200-8e HBA supports a x8 interface. The PCIe connection is through the edge connector, J7, which provides connections on both the top (J7B) and bottom (J7A) of the board. The signal definitions and pin numbers conform to the PCIe specification. SAS/SATA Connectors (J4 and J5). The LSISAS9200-8e HBA supports SAS/SATA connections through connectors J4 and J5, which are SFF-8088 mini-SAS, external, right-angle connectors. Activity LED Header (J3). The LSISAS9200-8e HBA has a 4-pin, right-angle, 0.1-in. pitch header for driving external activity LEDs. Table 5:
LSISAS9200-8e LED Header Pin
Function
1
3.3 V
2
Port 0
3
Port 1
4
3.3 V
UART Connector (TP2). The UART connector debug port requires a special cable and LSI support to gather detailed IOC status. Table 6:
Page 14
LSISAS9200-8e UART Pinout Pin
Function
1
UART0_TX
2
Gnd
3
UART0_RX
4
3.3 V
LSI Corporation Confidential | September 2010
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
Chapter 3: Host Bus Adapter Characteristics | Characteristics of the LSI PCIe to SAS HBAs
TP2
J3
J4 Port 1 LSISAS2008 J5 Port 0
J7
3_00003-03
Figure 2:
3.1.1.3
Physical Characteristics
LSI Corporation Confidential | September 2010
LSISAS9200-8e Board Layout
J7: PCIe x8-lane board edge connector
J4, J5: SFF-8088 mini-SAS, external, right-angle connectors
J3: 4-pin, right angle, 0.1-in. pitch pin header for driving external activity LED
TP2: UART connection
The LSISAS9200-8e HBA is a 6.6-in. x 2.713-in., low-profile board. PCIe connection is through the edge connector, J7. The component height on the top and bottom of the LSISAS9200-8e HBA follows the PCIe specification. The LSISAS9200-8e supports SAS/SATA connections through two SFF-8088 mini-SAS external connectors, J4 and J5.
Page 15
Chapter 3: Host Bus Adapter Characteristics | Characteristics of the LSI PCIe to SAS HBAs
3.1.2 LSISAS9210-8i HBA Characteristics
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
The LSISAS9210-8i HBA has onboard Flash ROM for firmware and BIOS, and NVSRAM for embedded mirroring. The LSISAS2008 controller brings 6Gb/s SAS performance to HBA, workstation, and server designs, making it easy to add a SAS interface to any PCIe system. Each of the eight SAS phys on the LSISAS2008 controller is capable of up to 6Gb/s SAS or SATA link rates.
3.1.2.1
LEDs
The LSISAS9210-8i HBA has a 4-pin header for connection of activity LEDs. The 4-pin header connects to two LEDs (see Table 7), which indicate SAS activity on Port 0 and Port 1.
3.1.2.2
Connectors
This section describes the different connectors on the LSISAS9210-8i HBA. See Figure 3 for connector locations. PCIe Connector (J6). The LSISAS9210-8i HBA supports a x8 interface. The PCIe connection is through the edge connector, J6, which provides connections on both the top (J6B) and bottom (J6A) of the board. The signal definitions and pin numbers conform to the PCIe specification. SAS/SATA Connectors (J4 and J5). The LSISAS9210-8i HBA supports SAS/SATA connections through connectors J4 and J5, which are SFF-8087 mini-SAS, internal, right-angle connectors. Activity LED Header (J3). The LSISAS9210-8i HBA has a 4-pin, right-angle, 0.1-in. pitch header for driving external activity LEDs. Table 7:
LSISAS9210-8i LED Header Pin
Function
1
3.3 V
2
Port 0
3
Port 1
4
3.3 V
UART Connector (TP1). The UART connector debug port requires a special cable and LSI support to gather detailed IOC status. Table 8:
Page 16
LSISAS9210-8i UART Pinout Pin
Function
1
UART0_TX
2
Gnd
3
UART0_RX
4
3.3 V
LSI Corporation Confidential | September 2010
Chapter 3: Host Bus Adapter Characteristics | Characteristics of the LSI PCIe to SAS HBAs
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
TP1
J3
LSISAS2008
J4
J5 J6
3_00004-03
Figure 3:
3.1.2.3
Physical Characteristics
LSI Corporation Confidential | September 2010
LSISAS9210-8i Board Layout
J6: PCIe x8-lane board edge connector
J4, J5: SFF-8087 mini-SAS, internal, right-angle connectors
J3: 4-pin, right angle, 0.1-in. pitch pin header for driving external activity LEDs
TP1: UART connection
The LSISAS9210-8i HBA is a 6.6-in. x 2.713-in. low-profile board. PCIe connection is through the edge connector, J6. The component height on the top and bottom of the LSISAS9210-8i HBA follows the PCIe specifications. The LSISAS9210-8i HBA supports SAS/SATA connections through two SFF-8087 mini-SAS internal connectors, J4 and J5.
Page 17
Chapter 3: Host Bus Adapter Characteristics | Characteristics of the LSI PCIe to SAS HBAs
3.1.3 LSISAS9211-8i HBA Characteristics
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
The LSISAS9211-8i HBA has onboard Flash ROM for firmware and BIOS, and NVSRAM for embedded mirroring. The LSISAS2008 controller brings 6Gb/s SAS performance to HBA, workstation, and server designs, making it easy to add a SAS interface to any PCIe system. Each of the eight SAS phys on the LSISAS2008 controller is capable of up to 6Gb/s SAS or SATA link rates.
3.1.3.1
LEDs
The LSISAS9211-8i HBA has a 4-pin header for connection of activity LEDs. The 4-pin header connects to two LEDs (see Table 9), which indicate SAS activity on Port 0 and Port 1.
3.1.3.2
Connectors
This section describes the different connectors on the LSISAS9211-8i HBA. See Figure 4 for connector locations. PCIe Connector (J1). The LSISAS9211-8i HBA supports a x8 interface. The PCIe connection is through the edge connector, J1, which provides connections on both the top (J1B) and bottom (J1A) of the board. The signal definitions and pin numbers conform to the PCIe specification. SAS/SATA Connectors (J7 and J8). The LSISAS9211-8i HBA supports SAS connections through connectors J7 and J8, which are SFF-8087 mini-SAS, internal, right-angle connectors. Activity LED Header (J6). The LSISAS9211-8i HBA has a 4-pin, right-angle, 0.1-in. pitch header for driving external activity LEDs. Table 9:
LSISAS9211-8i LED Header Pin
Function
1
3.3 V
2
Port 0
3
Port 1
4
3.3 V
UART Connector (J3). The UART connector debug port requires a special cable and LSI support to gather detailed IOC status. Table 10: LSISAS9211-8i UART Pinout
Page 18
Pin
Function
1
UART0_TX
2
Gnd
3
UART0_RX
4
3.3 V
LSI Corporation Confidential | September 2010
Chapter 3: Host Bus Adapter Characteristics | Characteristics of the LSI PCIe to SAS HBAs
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
J3 J6 J7 LSISAS2008 J8 J1
3_00005-03
Figure 4:
3.1.3.3
Physical Characteristics
LSI Corporation Confidential | September 2010
LSISAS9211-8i Board Layout
J1: PCIe x8-lane board edge connector
J3: UART connection
J7, J8: SFF-8087 mini-SAS, internal, right-angle connector
J6: 4-pin, right angle, 0.1-in. pitch, pin header for driving external activity LED
The LSISAS9211-8i HBA is a 6.6-in. x 2.713-in. low-profile board. PCIe connection is through the edge connector, J1. The component height on the top and bottom of the LSISAS9211-8i board follows the PCIe specifications. The LSISAS9211-8i HBA supports SAS/SATA connections through two SFF-8087 mini-SAS internal connectors, J7 and J8.
Page 19
Chapter 3: Host Bus Adapter Characteristics | Characteristics of the LSI PCIe to SAS HBAs
3.1.4 LSISAS9211-4i HBA Characteristics
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
The LSISAS9211-4i HBA has onboard Flash ROM for firmware and BIOS, and NVSRAM for embedded mirroring. The LSISAS2004 controller brings 6Gb/s SAS performance to HBA, workstation, and server designs, making it easy to add a SAS interface to any PCIe system. Each of the four SAS phys on the LSISAS2004 controller is capable of up to 6Gb/s SAS or SATA link rates.
3.1.4.1
LEDs
The LSISAS9211-4i HBA has a 4-pin header for connection of activity LEDs. The header connects to two LEDs (see Table 11), which indicate SAS activity on port 0 and port 1.
3.1.4.2
Connectors
This section describes the different connectors on the LSISAS9211-4i HBA. See Figure 5 for connector locations. PCIe Connector (J1). The LSISAS9211-4i HBA supports a x4 interface. The PCIe connection is through the edge connector, J1, which provides connections on both the top (J1B) and bottom (J1A) of the board. The signal definitions and pin numbers conform to the PCIe specifications. SAS/SATA Connector (J7). The LSISAS9211-4i supports SAS connections through connector J7, which is an SF8087 mini-SAS, internal, right-angle connector. Activity LED Header (J3). The LSISAS9211-4i HBA has a 4-pin, right-angle, 0.1-in. pitch header for driving external activity LEDs. Table 11: LSISAS9211-4i LED Header Pin
Function
1
3.3 V
2
Port 0
3
Port 0
4
3.3 V
UART Connector (J5). The UART connector debug port requires a special cable and LSI support to gather detailed IOC status. Table 12: LSISAS9211-4i UART Pinout
Page 20
Pin
Function
1
UART0_TX
2
Gnd
3
UART0_RX
4
3.3 V
LSI Corporation Confidential | September 2010
Chapter 3: Host Bus Adapter Characteristics | Characteristics of the LSI PCIe to SAS HBAs
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
J5 J3 J7 LSISAS2004
J1
3_00002-03
Figure 5:
3.1.4.3
Physical Characteristics
LSI Corporation Confidential | September 2010
LSISAS9211-4i Board Layout
J1: PCIe x4-lane board edge connector
J7: SFF-8087 mini-SAS, internal, right-angle connector
J3: 4-pin, right angle, 0.1-in. pitch, pin header for driving external activity LED
J5: UART connection
The LSISAS9211-4i HBA is a 6.6-in. x 2.713-in., low profile board. PCIe connection is through the edge connector, J1. The component height on the top and bottom of the LSISAS9211-4i HBA follows the PCIe specifications. The LSISAS9211-4i HBA supports SAS/SATA connections through one SFF-8087 mini-SAS internal connector, J7.
Page 21
Chapter 3: Host Bus Adapter Characteristics | Characteristics of the LSI PCIe to SAS HBAs
3.1.5 LSISAS9212-4i4e HBA Characteristics
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
The LSISAS9212-4i4e HBA has onboard Flash ROM for firmware and BIOS, and NVSRAM for embedded mirroring. The LSISAS2008 controller brings 6Gb/s SAS performance to HBA, workstation, and server designs, making it easy to add a SAS interface to any PCIe system. Each of the eight SAS phys on the LSISAS2008 controller is capable of up to 6Gb/s SAS or SATA link rates.
3.1.5.1
LEDs
The LSISAS9212-4i4e HBA has a 4-pin header for external connection of activity LEDs. The 4-pin header connects to two LEDs (see Table 13), which indicate SAS activity on Port 0 and Port 1.
3.1.5.2
Connectors
This section describes the different connectors on the LSISAS9212-4i4e HBA. See Figure 6 for connector locations. PCIe Connector (J1). The LSISAS9212-4i4e HBA supports a x8 interface. The PCIe connection is through the edge connector, J1, which provides connections on both the top (J1B) and bottom (J1A) of the board. The signal definitions and pin numbers conform to the PCIe specifications. SAS/SATA Connector (J5, J6, J7, J8, and J12). The LSISAS9212-4i4e HBA supports SAS/SATA connections through connector J12, which is an SFF-8088 mini-SAS, external, right-angle connector, and connectors J5, J6, J7, and J8, which are 7-pin SATA connectors. Activity LED Header (J11). The LSISAS9212-4i4e HBA has a 4-pin, right-angle, 0.1-in. pitch header for driving external activity LEDs. Table 13: LSISAS9212-4i4e LED Header
a.
Pin
Function
1
3.3 V
2
Port 0
3
Port 1a
4
3.3 V
Port 1 consists of the 7-pin SATA connectors on this HBA.
UART Connector (J3). The UART connector debug port requires a special cable and LSI support to gather detailed IOC status. Table 14: LSISAS9212-4i4e UART Pinout
Page 22
Pin
Function
1
UART_TX
2
Gnd
3
UART_RX
4
3.3 V
LSI Corporation Confidential | September 2010
Chapter 3: Host Bus Adapter Characteristics | Characteristics of the LSI PCIe to SAS HBAs
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
J4 J5
J6 LSISAS2008
J7
J8 J11
J12 Port 0
J1
3_00134-03
Figure 6:
3.1.5.3
Physical Characteristics
LSI Corporation Confidential | September 2010
LSISAS9212-4i4e Board Layout
J1: PCIe x4-lane board edge connector
J12: SFF-8088 mini-SAS, external, right-angle connector
J5, J6, J7, J8: 7-pin SATA connectors
J11: 4-pin, right angle, 0.1-in. pitch, pin header for driving external activity LED
J4: UART connection
The LSISAS9212-4i4e HBA is a 6.6-in. x 2.7-in. low profile board. PCIe connection is through the edge connector, J1. The component height on the top and bottom of the LSISAS9212-4i4e HBA follows the PCIe specification. The LSISAS9212-4i4e HBA supports SAS/SATA connections through one SFF-8088 mini-SAS external connector (J12) and four individual x1 internal SATA connectors (J5, J6, J7, and J8).
Page 23
Chapter 3: Host Bus Adapter Characteristics | Characteristics of the LSI PCIe to SAS HBAs
3.1.6 LSISAS9200-16e HBA Characteristics
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
The LSISAS9200-16e HBA has onboard Flash ROM for firmware and BIOS, and onboard DDR2 SDRAM. The LSISAS2116 controller brings 6Gb/s SAS performance to HBA, workstation, and server designs, making it easy to add a SAS interface to any PCIe system. Each of the sixteen SAS phys on the LSISAS2116 connector is capable of up to 6Gb/s SAS or SATA link rates.
3.1.6.1
LEDs
The LSISAS9200-16e HBA has two 4-pin headers for external connection of activity LEDs. The LEDs on header J4 correspond to activity on ports 2 and 3, and header J5 corresponds to activity on Port 0 and Port 1.
3.1.6.2
Connectors
This section describes the different connectors on the LSISAS9200-16e HBA. See Figure 7 for connector locations. PCIe Connector (J10). The LSISAS9200-16e HBA supports a x8 interface. The PCIe connection is through the edge connector, J10, which provides connections on both the top (J10B) and bottom (J10A) of the board. The signal definitions and pin numbers conform to the PCIe specification. SAS/SATA Connector (J6, J7, J8, J9). The LSISAS9200-16e HBA supports SAS connections through four external connectors: J6, J7, J8, and J9, which are SFF-8088 mini-SAS, external, right-angle connectors. Activity LED Headers (J4 and J5). The LSISAS9200-16e HBA has two 4-pin, right-angle, 0.1-in. pitch headers for driving external activity LEDs. Table 15: LSISAS9200-16e LED Header for J4 Pin
Function
1
3.3 V
2
Port 2
3
Port 3
4
3.3 V
Table 16: LSISAS9200-16e LED Header for J5
Page 24
Pin
Function
1
3.3 V
2
Port 0
3
Port 1
4
3.3 V
LSI Corporation Confidential | September 2010
Chapter 3: Host Bus Adapter Characteristics | Characteristics of the LSI PCIe to SAS HBAs
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
UART Connector (J3). The UART connector debug port requires a special cable and LSI support to gather detailed IOC status. Table 17: LSISAS9200-16e UART Pinout Pin
Function
1
UART_TX
2
Gnd
3
UART_RX
4
3.3 V
J3 J4
J5
J6 Port 3 J7 Port 2 J8 Port 1
LSISAS2016
J9 Port 0 J10
3-00133-03
Figure 7:
3.1.6.3
Physical Characteristics
LSI Corporation Confidential | September 2010
LSISAS9200-16e Board Layout
J10: PCIe x8-lane board edge connector
J6, J7, J8, J9: SFF-8088 mini-SAS, external, right-angle connectors
J4 and J5: 4-pin, right angle, 0.1-in. pitch pin header for driving external activity LED
J3: UART connection
The LSISAS9200-16e HBA is 9.0-in. x 4.2-in. PCIe connection is through the edge connector, J10. The component height on the top and bottom of the LSISAS9200-16e HBA follows the PCIe specifications. The SAS/SATA interface is through four SFF-8088 mini-SAS internal connectors, J6, J7, J8, and J9.
Page 25
Chapter 3: Host Bus Adapter Characteristics | Characteristics of the LSI PCIe to SAS HBAs
3.1.7 LSISAS9201-16i HBA Characteristics
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
The LSISAS9201-16i HBA has onboard Flash ROM for firmware and BIOS, and onboard DDR2 SDRAM. The LSISAS2116 controller brings 6Gb/s SAS performance to HBA, workstation, and server designs, making it easy to add a SAS interface to any PCIe system. Each of the sixteen SAS phys on the LSISAS2116 connector is capable of up to 6Gb/s SAS or SATA link rates.
3.1.7.1
LEDs
The LSISAS9201-16i HBA has two 4-pin headers for connection of activity LEDs. The LEDs on header J4 correspond to activity on ports C and D, and header J5 corresponds to activity on Port A and Port B.
3.1.7.2
Connectors
This section describes the different connectors on the LSISAS9201-16i HBA. See Figure 8 for connector locations. PCIe Connector (EC1). The LSISAS9201-16i HBA supports a x8 interface. The PCIe connection is through the edge connector, EC1, which provides connections on both the top (EC1B) and bottom (EC1A) of the board. The signal definitions and pin numbers conform to the PCIe specifications. SAS/SATA Connector (J6, J7, J8, J9). The LSISAS9201-16i HBA supports SAS connections through four external connectors: J6, J7, J8, and J9, which are SFF-8087 mini-SAS, internal, right-angle connectors. Activity LED Headers (J4 and J5). The LSISAS9201-16i HBA has two 4-pin, right-angle, 0.1-in. pitch headers for driving external activity LEDs. Table 18: LSISAS9201-16i LED Header for J4 Pin
Function
1
3.3 V
2
Port C
3
Port D
4
3.3 V
Table 19: LSISAS9201-16i LED Header for J5
Page 26
Pin
Function
1
3.3 V
2
Port A
3
Port B
4
3.3 V
LSI Corporation Confidential | September 2010
Chapter 3: Host Bus Adapter Characteristics | Characteristics of the LSI PCIe to SAS HBAs
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
UART Connector (J1). The UART connector debug port requires a special cable and LSI support to gather detailed IOC status. Table 20: LSISAS9201-16i UART Pinout Pin
Function
1
UART_TX
2
Gnd
3
UART_RX
4
3.3 V
J1 J4
J5
J6
Port A J7 Port B J8 Port C
LSISAS2016
J9 Port D
EC1 3_00201-01
Figure 8:
3.1.7.3
Physical Characteristics
LSI Corporation Confidential | September 2010
LSISAS9201-16i Board Layout
EC1: PCIe x8-lane board edge connector
J6, J7, J8, J9: SFF-8087 mini-SAS, internal, right-angle connectors
J4 and J5: 4-pin, right angle, 0.1-in. pitch pin header for driving external activity LED
J1: UART connection
The LSISAS9201-16i HBA is 6.6-in. x 4.2-in. PCIe connection is through the edge connector, EC1. The component height on the top and bottom of the LSISAS9201-16i board follows the PCIe specifications. The SAS/SATA interface is through four SFF-8087 mini-SAS internal connectors, J6, J7, J8, and J9.
Page 27
Chapter 3: Host Bus Adapter Characteristics | Characteristics of the LSI PCIe to SAS HBAs
3.1.8 LSISAS9201-16e HBA Characteristics
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
The LSISAS9201-16e HBA has onboard Flash ROM for firmware and BIOS, and onboard DDR2 SDRAM. The LSISAS2116 controller brings 6Gb/s SAS performance to HBA, workstation, and server designs, making it easy to add a SAS interface to any PCIe system. Each of the sixteen SAS phys on the LSISAS2116 connector is capable of up to 6Gb/s SAS or SATA link rates.
3.1.8.1
LEDs
The LSISAS9201-16e HBA has two 4-pin headers for external connection of activity LEDs. The LEDs on header J3 correspond to activity on ports C and D, and header J4 corresponds to activity on ports A and B.
3.1.8.2
Connectors
This section describes the different connectors on the LSISAS9201-16e HBA. See Figure 9 for connector locations. PCIe Connector (EC1). The LSISAS9201-16e HBA supports a x8 interface. The PCIe connection is through the edge connector, EC1, which provides connections on both the top (EC1B) and bottom (EC1A) of the board. The signal definitions and pin numbers conform to the PCIe specifications. SAS/SATA Connector (J6, J7, J8, J9). The LSISAS9201-16e HBA supports SAS connections through four external connectors: J6, J7, J8, and J9, which are SFF-8088 mini-SAS, external, right-angle connectors. Activity LED Headers (J3 and J4). The LSISAS9201-16e HBA has two 4-pin, right-angle, 0.1-in. pitch headers for driving external activity LEDs. Table 21: LSISAS9201-16e LED Header for J3 Pin
Function
1
3.3 V
2
Port C
3
Port D
4
3.3 V
Table 22: LSISAS9201-16e LED Header for J4
Page 28
Pin
Function
1
3.3 V
2
Port A
3
Port B
4
3.3 V
LSI Corporation Confidential | September 2010
Chapter 3: Host Bus Adapter Characteristics | Characteristics of the LSI PCIe to SAS HBAs
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
UART Connector (J5). The UART connector debug port requires a special cable and LSI support to gather detailed IOC status. Table 23: LSISAS9201-16e UART Pinout Pin
Function
1
UART_TX
2
Gnd
3
UART_RX
4
3.3 V
J5
J3
J4
J6 Port D J7 Port C J8 Port B
LSISAS2016
J9 Port A EC1
Figure 9:
3.1.8.3
Physical Characteristics
LSI Corporation Confidential | September 2010
3-00205-01
LSISAS9201-16e Board Layout
EC1: PCIe x8-lane board edge connector
J6, J7, J8, J9: SFF-8088 mini-SAS, external, right-angle connectors
J3 and J4: 4-pin, right angle, 0.1-in. pitch, pin header for driving external activity LED
J5: UART connection
The LSISAS9201-16e HBA is 6.6-in. x 4.2-in. PCIe connection is through the edge connector, EC1. The component height on the top and bottom of the LSISAS9200-16e HBA follows the PCIe specification. The SAS/SATA interface is through four SFF-8088 mini-SAS external connectors, J6, J7, J8, and J9.
Page 29
Chapter 3: Host Bus Adapter Characteristics | Characteristics of the LSI PCIe to SAS HBAs
3.1.9 LSISAS9202-16e HBA Characteristics
3.1.9.1
Connectors
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
The LSISAS9202-16e HBA has onboard Flash ROM for firmware and BIOS. The two LSISAS2008 controllers bring 6Gb/s SAS performance to HBA, workstation, and server designs, making it easy to add a SAS interface to any PCIe system. Each of the SAS phys on the two LSISAS2008 connectors is capable of up to 6Gb/s SAS or SATA link rates. This section describes the different connectors on the LSISAS9202-16e HBA. See Figure 10 for connector locations. PCIe Connector (EC1). The LSISAS9202-16e HBA supports a x16 interface. The PCIe connection is through the edge connector, EC1, which provides connections on both the top (EC1B) and bottom (EC1A) of the board. The signal definitions and pin numbers conform to the PCIe specification. SAS/SATA Connector (J3). The LSISAS9202-16e HBA supports SAS connections through four external connectors: J3, ports A, B, C, and D, which are SFF-8644 mini-SAS HD, external, right-angle connectors. The LSISAS9202-16e HBA also supports active cables. UART Connector (J2, J5). The UART connector debug port requires a special cable and LSI support to gather detailed IOC status. Both of the UART headers have the following pinout. Table 24: LSISAS9202-16e UART Pinout
Page 30
Pin
Function
1
UART_TX
2
Gnd
3
UART_RX
4
3.3 V
LSI Corporation Confidential | September 2010
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
Chapter 3: Host Bus Adapter Characteristics | Characteristics of the LSI PCIe to SAS HBAs
J2 J3 Port A
F0 LSISAS2008
J3 Port B J3 Port C
F1 LSISAS2008
J3 Port D EC1
J5
3-00394-00
Figure 10:
3.1.9.2
Physical Characteristics
LSI Corporation Confidential | September 2010
LSISAS9202-16e Board Layout
EC1: PCIe x16-lane board edge connector
J3, Ports A, B, C, D: SFF-8644 mini-SAS HD external connectors
J2, J5: UART connections
The LSISAS9202-16e HBA is 6.6-in. x 2.7-in. PCIe connection is through the edge connector, EC1. The component height on the top and bottom of the LSISAS9202-16e HBA follows the PCIe specification. The SAS/SATA interface is through four SFF-8644 mini-SAS HD external connectors, labeled ports A, B, C, and D of connector J3.
Page 31
Chapter 3: Host Bus Adapter Characteristics | Electrical and Environmental Specifications
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide
3.2 Electrical and Environmental Specifications
The design and implementation of the LSI PCIe to SAS HBAs minimizes electromagnetic emissions, susceptibility to radio frequency energy, and the effects of electrostatic discharge. The board carries the CE mark, C-Tick mark, Canadian Compliance Statement, Korean KCC, Taiwan BSMI, Japan VCCI, and FCC Class B, and it is marked with the FCC Self-Certification logo. The board also meets the requirements of CISPR Class B.
3.2.1
The following table lists the maximum power requirements for the LSI PCIe to SAS HBAs under normal operation.
Electrical Characteristics
Table 25: Maximum Power Requirements HBA Model
PCIe 12.0 V
Power
Operating Range
LSISAS9200-8e
0.74 A
8.84 W
0 °C to 55 °C
LSISAS9210-8i
0.66 A
7.92 W
0 °C to 55 °C
LSISAS9211-8i
0.70 A
8.38 W
0 °C to 55 °C
LSISAS9211-4i
0.57 A
6.86 W
0 °C to 55 °C
LSISAS9212-4i4e
0.67 A
7.2 W
0 °C to 55 °C
LSISAS9200-16e
1.35 A
16.2 W
0 °C to 55 °C
LSISAS9201-16i
1.35 A
16.2 W
0 °C to 55 °C
LSISAS9201-16e
1.35 A
16.2 W
0 °C to 55 °C
LSISAS9202-16ea
1.91 A
24.3 W
0 °C to 55 °C
a.
3.2.2 Thermal and Atmospheric Characteristics
The power requirements data for this HBA assumes 4 active mini-SAS HD cables drawing 1 W each.
The atmospheric characteristics for the LSI PCIe to SAS HBAs are as follows:
Temperature range: 0 °C to 55 °C (dry bulb)
Relative humidity range: 5% to 90% noncondensing
Maximum dew point temperature: 32 °C
The following parameters define the storage and transit environment for the LSI PCIe to SAS HBAs:
3.2.3
Page 32
Safety Characteristics
Temperature range: 45 °C to +105 °C (dry bulb)
Relative humidity range: 5% to 90% noncondensing
All LSI PCIe to SAS HBAs meet or exceed the requirements of UL flammability rating 94V-0. Each bare board is marked with the supplier’s name or trademark, type, and UL flammability rating. Because these boards are installed in a PCIe bus slot, all voltages are below the SELV 42.4-V limit.
LSI Corporation Confidential | September 2010