PD404
Digital Lighting Systems www.digitallighting.com
4 x 500Watts dimmer pack SPECIFICATIONS Page 1
PROTOCOL
4.6 (117 mm)
Top View
Low Voltage Ports 1.25 (32 mm)
2.4" (61 mm)
1.1” (28mm)
3.2” 1.9" (82 mm) (48 mm)
1.40”" (36 mm)
J3 Data & J1 Data Power Only
1/2” and 3/4” Conduit Knockouts
1.80” (46 mm)
Bottom View
2.4” (61 mm) 3.1” (79 mm) 2
1
3
F4
INT04 T3
L4
F2
F3 L3
L2
L1
F1
Ground
T2
8.5” (216 mm)
INT04 PROTOCOL 4 Dimmers Firing Board
4
T4
T1
HOT NEUTRAL
3
2
11.2” (285 mm)
4
S2-S1 Address selectors
PD404 PROTOCOL 4 x 4 Amps Dimmer Pack
J2
F 012
D BC E
DE
BC
10 VAC Transformer
W3 W4
789A
J3
F 012
3456
S2
3456
LED's
Address selectors
S2
5
789A
J1
1
8
PD404
S1
Control Indicators
1 2 3 4
Output indicators
www.digitallighting.com Digital Lighting Systems, Inc.
6
OPTO-ISOLATORS
S1
7
4.6" (117 mm)
PD404 Front Cover
General Description The PD404 dimmer pack contains four solid-state dimmers rated each for a maximum load of 480 Watts at 120 VAC. Power is fed to the PD404 from One 20 AMPS breaker.. The dimmers are triggered by a separate firing board (INT04). The INT04 is a microprocessor based control board with a nonvolatile memory chip, a communications chip, and a regulated DC power supply. The INT04 also contains, address selectors, LED output monitors and other support circuitry. The microprocessor is driven by powerful distributed intelligence software which handles all control and communications functions. The memory chip holds all of the PD404's pertinent information and settings which include low and high trim levels for each of the four outputs. The PD404 does not rely on any shared data source and functions independently of any other system component and without a central system controller. The PD404 communicates with Protocol system stations and controllers over a single twisted-pair of wires and can be connected anywhere on the system network bus. This adds convenience and versatility by allowing PD404 dimmers to be installed close to their loads and/or service panels.
General Features . Distributed Intelligence. . Modular and Compact Design. . Twisted-pair Balanced Line Communications. . Daisy Chain, T-tap, or Star Data Configurations. . Software Configurable. . Automatic 50/60 Hz Detection. . Dimming Disable Jumper. . Powerful Built-in Diagnostics.
Control & Diagnostics . . . . . . . . . . .
Set Load Intensity Level. Save/Recall Presets. Blink Load. Set Load Max. & Min. Trims. View Max. & Min. Trim Settings View Current Output Levels. View ID and Code Version. Default to Factory settings. Save Settings in memory. Download Configuration File. Check Status.
12302 SW 128 Ct. Bay #105 Miami, FL 33186 Copyright
Physical and Electrical Specifications Enclosure: Weight: Power Feed: Voltage Feed: Output Rating: Output Triacs: Connector: Data Network: Protocol. Data Retention: ESD Protection:
11.5”x4.6”x3.3”/ .090 Aluminum 3 Lbs. (1.35 Kgs.) 1 x 20 Amp. Feeds. 120 VAC, 50/60Hz, Single Phase. 4 x 480 Watts @120 VAC.Fused Max. Rating 25 A-600 VAC 7-position screw terminal block. RS485 Compliant, Proprietary 10 years, no batteries required. 15 KV on data input and output.
Tel: 305-969-8442 Fax: 305-969-8675
2007 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.
PD404-SPECS 07/07
PD404
Digital Lighting Systems www.digitallighting.com
PROTOCOL Components Side INT04
SSR4
SSR2
SSR3
SSR1
H N N 1 2 3 4
Earth Ground
4 x 500Watts dimmer pack SPECIFICATIONS Page 2
1 2 3 4 5 6 7 8 9
3
2 4 1
N
H
5 9 VAC Transformer
9 789A
D BC E
3456
3456
789A
INT04 Control Board
D BC E
F 012
F 012
S2
S1
8
6
SSR's OPTICAL ISOLATORS J3
S1-S2 Address Selectors.
7
LDM
Microprocessor. Nonvolatile Memory. Communications Chip. Quartz Crystal. Power Supply Capacitor. Voltage Regulator. Signal & Power Connector. Output LED Monitors. Jumper for switches only
FUNCTIONAL BLOCK DIAGRAM
RJ45 Female Connectors
Mounting Requirements Surface mount the dimmer pack in a well ventilated area. Allow 2" of side clearance for proper air circulation. Installation clearance shall meet local and/or NEC code requirements. Enclosures may be attached to the wall or other mounting surface by holes in the heat sink flanges. Refer to the drawing on the front side of this sheet for the proper dimensions. Conduit shall be pulled to the top of the dimmer packs.
Wiring Notes K DO NOT EXCEED 480 W per dimmer output. L All wiring (network bus) between the control stations, dimmers, and other system components is low voltage (NEMA Class 2) and may be run with two twisted pair #18 AWG wire. Control network bus may be Carol Cable #C3362 unless otherwise required. Consult the Protocol Hardware Installation manual, appendix E, for maximum wire length. M Multiple PD404s could be fed from 120V/208V three phase service Breaker panel. N PD404 Needs One 20 A. breaker and shall have up to four separately dimmed loads. O Please refer to the PD404 and Protocol system installation manuals for complete wiring information. P CAUTION: DO NOT attempt to parallel outputs to increase capacity. Q INSTALLATION must be performed by a certified Electrician and must conform to local and/or NEC code requirements. R PD404 Does not have any user serviceable parts. S RJPD-6’ - RJ45 Daisy-Chain Network Cable is supplied with each PD404 to connect to other PD Series units. Refer to PROTOCOL installation manual for connecting Pd404 to PS control stations and other PROTOCOL components 2 #12 AWG Typical 1 HOT & 1NEUT. To Distribution Panel
Data
Data
RJ45- Data DB44 RJ45 JACK
Small Protocol Systems
Power
01
To Loads Pre-terminated CAT5 network cables (RJPD-6) are supplied PD404 with each PD404 pack for connecting to other PD dimmer modules and to DB44. 02
9-10V External Power Transformer (For Stations & Control Modules)
To Loads
PD404
DB44
9 VAC Data & Power
DB44 9VAC Power & Data Distribution Panel
A small Protocol system can be built using only one PD404 and one station. The station gets its power from the PD404's transformer by installing jumpers W1 & W2 on the load driver module (LDM). The DB44 and external transformer are not required in small systems. (See the Protocol and the PD404 installation manuals for more details.)
12302 SW 128 Ct. Bay #105 Miami, FL 33186 Copyright
Typical Protocol System Layout
TO AC outlet
RAU-96 (Optional)
2 Twisted-Pair Network Cable
DCI-16 Dry Contact Input Interface (Optional)
Tel: 305-969-8442 Fax: 305-969-8675
2007 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.
DCO-4 Dry Contact Output Interface (Optional)
PD404-SPECS 07/07