Preview only show first 10 pages with watermark. For full document please download

Pd404/pd404-s Spec. Sheets

   EMBED


Share

Transcript

PD404 Digital Lighting Systems www.digitallighting.com 4 x 500Watts dimmer pack SPECIFICATIONS Page 1 PROTOCOL 4.6 (117 mm) Top View Low Voltage Ports 1.25 (32 mm) 2.4" (61 mm) 1.1” (28mm) 3.2” 1.9" (82 mm) (48 mm) 1.40”" (36 mm) J3 Data & J1 Data Power Only 1/2” and 3/4” Conduit Knockouts 1.80” (46 mm) Bottom View 2.4” (61 mm) 3.1” (79 mm) 2 1 3 F4 INT04 T3 L4 F2 F3 L3 L2 L1 F1 Ground T2 8.5” (216 mm) INT04 PROTOCOL 4 Dimmers Firing Board 4 T4 T1 HOT NEUTRAL 3 2 11.2” (285 mm) 4 S2-S1 Address selectors PD404 PROTOCOL 4 x 4 Amps Dimmer Pack J2 F 012 D BC E DE BC 10 VAC Transformer W3 W4 789A J3 F 012 3456 S2 3456 LED's Address selectors S2 5 789A J1 1 8 PD404 S1 Control Indicators 1 2 3 4 Output indicators www.digitallighting.com Digital Lighting Systems, Inc. 6 OPTO-ISOLATORS S1 7 4.6" (117 mm) PD404 Front Cover General Description The PD404 dimmer pack contains four solid-state dimmers rated each for a maximum load of 480 Watts at 120 VAC. Power is fed to the PD404 from One 20 AMPS breaker.. The dimmers are triggered by a separate firing board (INT04). The INT04 is a microprocessor based control board with a nonvolatile memory chip, a communications chip, and a regulated DC power supply. The INT04 also contains, address selectors, LED output monitors and other support circuitry. The microprocessor is driven by powerful distributed intelligence software which handles all control and communications functions. The memory chip holds all of the PD404's pertinent information and settings which include low and high trim levels for each of the four outputs. The PD404 does not rely on any shared data source and functions independently of any other system component and without a central system controller. The PD404 communicates with Protocol system stations and controllers over a single twisted-pair of wires and can be connected anywhere on the system network bus. This adds convenience and versatility by allowing PD404 dimmers to be installed close to their loads and/or service panels. General Features . Distributed Intelligence. . Modular and Compact Design. . Twisted-pair Balanced Line Communications. . Daisy Chain, T-tap, or Star Data Configurations. . Software Configurable. . Automatic 50/60 Hz Detection. . Dimming Disable Jumper. . Powerful Built-in Diagnostics. Control & Diagnostics . . . . . . . . . . . Set Load Intensity Level. Save/Recall Presets. Blink Load. Set Load Max. & Min. Trims. View Max. & Min. Trim Settings View Current Output Levels. View ID and Code Version. Default to Factory settings. Save Settings in memory. Download Configuration File. Check Status. 12302 SW 128 Ct. Bay #105 Miami, FL 33186 Copyright Physical and Electrical Specifications Enclosure: Weight: Power Feed: Voltage Feed: Output Rating: Output Triacs: Connector: Data Network: Protocol. Data Retention: ESD Protection: 11.5”x4.6”x3.3”/ .090 Aluminum 3 Lbs. (1.35 Kgs.) 1 x 20 Amp. Feeds. 120 VAC, 50/60Hz, Single Phase. 4 x 480 Watts @120 VAC.Fused Max. Rating 25 A-600 VAC 7-position screw terminal block. RS485 Compliant, Proprietary 10 years, no batteries required. 15 KV on data input and output. Tel: 305-969-8442 Fax: 305-969-8675 2007 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A. PD404-SPECS 07/07 PD404 Digital Lighting Systems www.digitallighting.com PROTOCOL Components Side INT04 SSR4 SSR2 SSR3 SSR1 H N N 1 2 3 4 Earth Ground 4 x 500Watts dimmer pack SPECIFICATIONS Page 2 1 2 3 4 5 6 7 8 9 3 2 4 1 N H 5 9 VAC Transformer 9 789A D BC E 3456 3456 789A INT04 Control Board D BC E F 012 F 012 S2 S1 8 6 SSR's OPTICAL ISOLATORS J3 S1-S2 Address Selectors. 7 LDM Microprocessor. Nonvolatile Memory. Communications Chip. Quartz Crystal. Power Supply Capacitor. Voltage Regulator. Signal & Power Connector. Output LED Monitors. Jumper for switches only FUNCTIONAL BLOCK DIAGRAM RJ45 Female Connectors Mounting Requirements Surface mount the dimmer pack in a well ventilated area. Allow 2" of side clearance for proper air circulation. Installation clearance shall meet local and/or NEC code requirements. Enclosures may be attached to the wall or other mounting surface by holes in the heat sink flanges. Refer to the drawing on the front side of this sheet for the proper dimensions. Conduit shall be pulled to the top of the dimmer packs. Wiring Notes K DO NOT EXCEED 480 W per dimmer output. L All wiring (network bus) between the control stations, dimmers, and other system components is low voltage (NEMA Class 2) and may be run with two twisted pair #18 AWG wire. Control network bus may be Carol Cable #C3362 unless otherwise required. Consult the Protocol Hardware Installation manual, appendix E, for maximum wire length. M Multiple PD404s could be fed from 120V/208V three phase service Breaker panel. N PD404 Needs One 20 A. breaker and shall have up to four separately dimmed loads. O Please refer to the PD404 and Protocol system installation manuals for complete wiring information. P CAUTION: DO NOT attempt to parallel outputs to increase capacity. Q INSTALLATION must be performed by a certified Electrician and must conform to local and/or NEC code requirements. R PD404 Does not have any user serviceable parts. S RJPD-6’ - RJ45 Daisy-Chain Network Cable is supplied with each PD404 to connect to other PD Series units. Refer to PROTOCOL installation manual for connecting Pd404 to PS control stations and other PROTOCOL components 2 #12 AWG Typical 1 HOT & 1NEUT. To Distribution Panel Data Data RJ45- Data DB44 RJ45 JACK Small Protocol Systems Power 01 To Loads Pre-terminated CAT5 network cables (RJPD-6) are supplied PD404 with each PD404 pack for connecting to other PD dimmer modules and to DB44. 02 9-10V External Power Transformer (For Stations & Control Modules) To Loads PD404 DB44 9 VAC Data & Power DB44 9VAC Power & Data Distribution Panel A small Protocol system can be built using only one PD404 and one station. The station gets its power from the PD404's transformer by installing jumpers W1 & W2 on the load driver module (LDM). The DB44 and external transformer are not required in small systems. (See the Protocol and the PD404 installation manuals for more details.) 12302 SW 128 Ct. Bay #105 Miami, FL 33186 Copyright Typical Protocol System Layout TO AC outlet RAU-96 (Optional) 2 Twisted-Pair Network Cable DCI-16 Dry Contact Input Interface (Optional) Tel: 305-969-8442 Fax: 305-969-8675 2007 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A. DCO-4 Dry Contact Output Interface (Optional) PD404-SPECS 07/07