Preview only show first 10 pages with watermark. For full document please download

Pdc Series - Dc Ups Prolink Dc Ups

   EMBED


Share

Transcript

Solar PROLiNK DC UPS PDC Series - DC UPS PROLiNK DC Series is a compact design of DC UPS system which converts AC power to DC power with dynamic voltage regulator; the UPS can ensure stable DC power to connected load as utility. This UPS system is an economic ideal for communication devices such as switch, hub, router and modem.The built-in DC start function enables the UPS to be started up without supply of AC power. To consider that facilitate and can be used under various circumstances, PROLiNK DC series has design with a very compact size for locate and storage. PDC50 • Dual DC Outputs • Microprocessor controlled guarantees high reliability • Compact size for standing and mounting flexibility • Supports solar powered devices and communication applications • Auto restart while AC is recovering • Off-mode charging • Overload protection and short circuit protection Full Specifications MODELS PDC50 Capacity 50W INPUT Nominal Voltage Voltage Range Frenquency 220VAC 160 - 280VAC 50 or 60Hz OUTPUT Nominal Voltage Output Voltage Regulation Transfer Time 12VDC 10V ~ 13.7V 0ms EFFICIENCY AC Mode Battery Mode >75% at Nominal Voltage (Battery Fully Charged) >95% at Full Load BATTERY Battery Type Charging Voltage Charging Current Typical Recharge Time 12V9AH x 1 13.7V ±0.25V 2.8A or 2.3A at Nominal Voltage without Load 4 ~ 6 hours recover to 90% capacity INDICATION AC Mode Green Lighting Battery Mode Yellow Lighting Low Battery Yellow Flashing Fault PROTECTION Full Protection Red Lighting Short Circuit and Overload Protection PHYSICAL Dimension (mm) D x W × H @ Vertically Stand Net Weight (kgs) 228 x 82.5 x 207 3 ENVIRONMENT Humidity Temperature 0 ~ 90% 0°C ~ 40°C All specifications, designs and contents are subjected to changes without prior notice 35 Solar PROLiNK Solar System PCC Series PCC Series is a combination of MPPT technology and DSP controller system, it will convert best voltage to charge battery based on varied temperature. Compared to traditional solar charger controller, it allows your solar panels to operate at their optimum power output voltage, providing higher efficiency up to 97.7% with lower power loss. PCC Series with inverter, solar panel, and external battery packs; it will become a standalone solar power system to generate green power for your home application. PCC Series will convert solar power to charge external batteries, and then provide power to home appliances via inverter. It’s compatible to 4 different battery types, sealed lead acid, vented, gel and NiCd. PCC300 PCC600 • Intelligent Maximum Power Point Tracking technology • Built-in DSP controller with high performance • Automatic battery voltage detection • Three-stage charging optimizes battery performance • Auto load-detection • Multifunction LCD displays detailed information • Reverse polarity protection of solar panel and battery • Overcharge and overload protection • IP 43 protection for outdoor and harsh environment #1 • IP 21 protection #2 • Suitable for battery types of sealed lead acid, vented Gel, and NiCd • Standard RJ45 port or optional RS-485 communication port for remote monitoring PCC3000 Full Specifications MODELS PCC300 PCC600 PCC3000 Capacity 300W 600W 3000W 15 ~ 33V @ 12V 30 ~ 66V @ 24V 60 ~ 132VDC 50V 75V 150VDC INPUT MPPT Range @ Operating Voltage Maximum PV Array Open Circuit Voltage Maximum Current 18A 45A OUTPUT Nominal Battery Voltage 12V Connected Battery Type Maximum Charging Current 24V 48V Sealed Lead Acid, Vented, Gel, MiCd Battery 25A 60A Ripple Voltage <±1V Maximum Efficiency 97.8% Stanby Power Consumption 98% 1W Charging Method 2W Three Stages: Bulk, Absorption & Floating PROTECTIONS Overload Protection >110%: Audiable Alarm INDICATION LCD Panel Yes Yes Yes Overcharge Protection Polarity Reversal Protection @ Solar Cell & Battery LCD Panel indicating Solar Power, Output Power, Battery Voltage, Charging Current, and Fault Conditions LED Display Three indiators: Solar, Charging & Load Status Three indiators: Solar, Battery & Wiring Fault PHYSICAL Dimension (mm) D x W × H Net Weight (kgs) Connector Type of Mechanical Protection 135 x 170 x 57.5 0.92 220 x 170 x 57.5 1.85 Input or Output Terminal Block IP43 180 x 210 x 80 1.28 IP21 ENVIRONMENT Humidity Operating Temperature Storage Temperature Altitude 0~90% Relative Humidity (non-condensing) -20°C to 55°C -40°C to 75°C 0 ~ 3000m #1 Only applicable to Model with 50~300W. #2 Only applicable to Model with 3000W. All specifications, designs and contents are subjected to changes without prior notice. 36 Solar PROLiNK Solar System PSI Hybrid Series PSI Hybride Series is a hybrid inverter which combines solar system, AC utility, and battery power source to supply continuous power. It is suitable for the remote areas where the cost of utility is too high or emergency usage when utility is not stable. The system will supply the load and feed power back to the utility grid when the PV energy output is available. When the PV energy output is not sufficient for connected loads, the inverter will convert to the utility grid at the same time. HYBRID 3K • Daytime or sunny day, works as an On Grid Inverter Night time or rainy day, works as an Off Grid Inverter • Pure sine wave output • Multiple operations: Grid tie, Off grid, and grid-tie with backup • Built-in MPPT solar charger • LCD display panel for comprehensive information • Multiple communication • Green substitution for generators Full Specifications MODELS HYBRID 3K Capacity 3000W INPUT (DC) Maximum DC Voltage 500VDC MPP Voltage Range 250VDC ~ 450VDC DC Nominal Voltage 360VDC Maximum Input Current 13A GRID/ UTILITY INPUT (AC) Nominal AC Voltage/ Range Maximum Input Current 208/ 220/ 230/ 240VAC / 175 ~ 280 VAC 20A GRID OUTPUT (AC) Nominal AC Voltage/ Range AC Grid Frequency Range Nominal Output Current Power Factor BATTERY MODE OUTPUT (AC) Output Voltage 208/ 220/ 230/ 240VAC / 184 ~ 265VAC 47.5 ~ 50.2Hz 13A >0.99 208/220/230/240 VAC Output Frequency 50Hz Output Waveform Pure Sinewave Efficiency (DC to AC) 92% BATTERY & CHARGE Nominal DC Voltage Maximum Charging Current PHYSICAL Dimension (mm) D x W × H Net Weight (kgs) 48VDC 25A 420 x 415 x 170 15.5 INTERFACE Communication Port Intelligent Slot Wireless Connection RS-485/ RS-232 Optional SNMP Card and Modbus Card available Optional Zigbee Card and Wireless device available ENVIRONMENT Humidity Operating Temperature Altitude 0~90% Relative Humidity (non-condensing) -25°C to 60°C 0 ~ 1000m (Power derating 1% every 100m when altitude is over 1000m) All specifications, designs and contents are subjected to changes without prior notice. 37 Solar PROLiNK Solar System PSI On-Grid Series PSI On-Grid Series can operate at their optimum power output voltage even under variety of weather conditions. Amnetz PV inverters also allow a wide input voltage range to generate maximum 96% efficiency. Besides, it also offers user-friendly design and modulated electric design. Bundled with monitoring software, Amnetz PV inverters can monitor and calculate the accurate saving energy. • 1.5KW/2KW/3KW/5KW & 3-phase 10KW on-grid PV inverter • Advanced DSP control technology delivers accurate data • Smart MPPTs to enhance overall efficiency • Modulized design for easy maintenance • Industrial-grade components used for robust operation • Data log up to 15 years • IP 65 protection for outdoor and harsh environment • Comprehensive LCD monitor for easy-reading • Free monitoring software AMNETZ 1500 AMNETZ 2000 AMNETZ 3000 Full Specifications MODELS AMNETZ 1500 Capacity Phase 1500W AMNETZ 2000 AMNETZ 3000 AMNETZ 5000 AMNETZ 10K 5000W 10000W 3 Phase-In 3 Phase-Out 11000W 2000W 3000W 1 Phase-In 1 Phase-Out INPUT (DC) Maximum DC Power 1650W 2200W 3200W 5300W Maximum DC Voltage 450VDC 500VDC 500VDC 500VDC 150 ~ 400VDC 200 ~ 450VDC MPP Voltage Range Nominal DC Voltage Start-up Voltage/ Initial Feeding Voltage Maximum Input Current/ Per String OUTPUT (AC) Nominal AC Voltage 900VDC 320 ~ 800VDC 360VDC 370VDC 600VDC 125/ 150VDC 116/ 150VDC 250/ 250VDC 11A 230VAC 230VAC AC Voltage Range 10A 16A 17A 230VAC 230VAC 3/ N/ PE, 230/ 400VAC 21.7A 14.5A -20% ~ +15% AC Grid Frequency Nominal Output Current 150 ~ 500VDC 50Hz / 60Hz 6.6A 8.7A 13A >0.99 Power Factor EFFICIENCY Maximum Efficiency 96.0% 96.5% 98.0% PROTECTION DC Reverse-Polarity Protection Yes Ground Fault Monitoring Grid Monitoring Yes Yes AC Short Circuit Protection Yes PHYSICAL Dimension (mm) D x W × H Net Weight (kgs) 136.5 x 268.5 x 410 160 x 270 x 450 182 x 308 x 515 171.2 x 503.5 x 653.3 11.5 15 20 40 INTERFACE Intelligent Slot ENVIRONMENT Humidity Operating Temperature Altitude USB Card/ Optional: SNMP, RS-232, AS-400 and GPRS Cards 0 ~ 100% Relative Humidity (Non-condesing) -25 ~ 60°C -25 ~ 55°C -25 ~ 60°C 0 ~ 1000m (Power derating 1% every 100m when altitude is over 1000m) COMPLIANCE Standard CE, VDE 0126-1-1, IEC62109, ENEL Guide 2009, RD 1663, G83/ 1-1, AS3100/ AS4777 All specifications, designs and contents are subjected to changes without prior notice. 38 Solar PROLiNK Solar System PSI Off-Grid Series PSI Off-Grid Series is an off grid PV inverter which consists of three power sources such as PV modules, battery power, and AC power sources. The AC power source could be supply by the generator or utility grid. Offnetz utilizes either sun energy or self-generated AC source to convert stable power for house and commercial applications. It’s perfect choice for long-term power backup request in unstable power area and remote village. OFFNETZ 2000 OFFNETZ 3000 • DSP plus microprocessor redundant controllers. • Pure sine wave output • Isolation design between inverter and battery. • LCD display and recorded up to 15 years • Provides multiple communication ports for remote monitoring with software. • Optional Modbus, SNMP, GPRS communication and AS400 dry contact. • Option: On-Grid Full Specifications MODELS OFFNETZ 2000 OFFNETZ 3000 Capacity 2000W 3000W PV INPUT (DC) Maximum DC Voltage Full Load MPP Voltage Range 500VDC 500VDC 170 ~ 450VDC 250 ~ 450VDC Maximum Input Current AC INPUT Nominal AC Voltage 13A 100/ 110/ 120/ 127VAC 208/ 220/ 230/ 240VAC Acceptable Voltage Range 85 ~ 145VAC 175 ~ 265VAC/ 175 ~ 280VAC Acceptable Frequency Range 57.5 ~ 62.5Hz 47.5 ~ 52.2Hz 31A 20A 100/ 110/ 120/ 127VAC 208/ 220VAC or 230/ 240VAC Maximum Input Current BATTERY MODE OUTPUT (AC) Output Voltage Output Frequency 60Hz Output Waveform THDv <3% @ Linear Load Power Factor Efficiency (DC to AC) Overload Capability BATTERY & CHARGER Nominal DC Voltage Maximum Charging Current 50Hz Pure Sinewave >0.99 90% 92% >110%: 5mins; >150%: 1min, 200%: Immediately 48VDC 25A PHYSICAL Dimension (mm) D x W × H (Without Wheels) Net Weight (kgs) 420 x 415 x 170 15.5 INTERFACE Communication Port Intelligent Slot RS-232/ USB Optional SNMP Card, ModBus Card, GPRS, And AS-400 Card Available ENVIROMENT Humidity Operating Temperature Altitude 0 ~ 90% Relative Humidity (non-condensing) 0 ~ 40°C 0 ~ 1000m (Power derating 1% every 100m when altitude is over 1000m) All specifications, designs and contents are subjected to changes without prior notice. 39 Solar PROLiNK Solar System PSS Series PSS Series is standalone solar power station consists of a solar charge controller, inverter, and a battery pack. This solar power station provides clean power and cheaper operation cost to home and commercial application. To consider that facilitate and can be used under various circumstances, Sonnensys is design for easy installation and limited space requirement. • Easy installation: No technician need • Low cost • Unlimited and clean power source from sun • Expandable based on project need SONNENSYS 850 SONNENSYS 150/ SONNENSYS 15PRO Full Specifications MODELS Capacity 850VA/ 480W INPUT (AC) Voltage Selectable Voltage Range SONNENSYS 1500 SONNENSYS 850 Volt-Amp/ Watt SONNENSYS 1500 PRO 1500VA/ 1050W 120VAC or 230VAC 230VAC For PCs 95 ~ 145VAC or 180 ~ 260VAC 180 ~ 260VAC For Home Appliances 50 ~ 160VAC or 100 ~ 300VAC 100 ~ 300VAC Ferquency Range 50/ 60Hz (Auto-Sensing) OUTPUT (AC) AC Voltage Regulation (Battery Mode) 100 ~ 120VAC ±5% or 200 ~ 2300VAC ±5% 200 ~ 230VAC ±5% Transfer Time 230VAC ±5% 20ms Typical Waveform (Battery Mode) Simulated Sinawave Pure Sinewave 31A SOLAR CHARGER MPPT Range @ Operating Voltage Maximum PV Array Open Circuit Voltage Maximum PV Array Power 20A 15 ~ 33VDC 50VDC 30 ~ 66V 75VDC 300W 600W 18A Maximum Charging Current BATTERY Number & Type of Battery 1 x 12V100AH 2 x 12V100AH Battery Voltage Floating Charge Voltage 12VDC 13.7VDC ±2% 24VDC 27.4VDC ±2% Maximum Charging Current 35A (10A AC Charger + 25A Solar Charger) or 45A (20A AC Charger + 25A Solar Charger) PROTECTION Full Protection Overload & Short Circuit Protection ALARM Low Battery Sounding every secound Overload Sounding every 0.5 secound Battery Replacement Sounding every 2 secound Fault Continuously Sounding PHYSICAL Dimension (mm) D x W x H (Without Wheels) Net Weight (kgs) 53 OPERATING EBVIRONMENT Humidity Temperature 480 x 250 x 450 Operating Storage 480 x 420 x 420 92 94 0 ~ 90% Relative Humidity (Non-condensing) 0 ~ 50°C -15 ~ 70°C All specifications, designs and contents are subjected to changes without prior notice. 40