Preview only show first 10 pages with watermark. For full document please download

Pdf, Updated 05/14/2010

   EMBED


Share

Transcript

ESX Server 3 Configuration Guide Update 2 and later for ESX Server 3.5 and VirtualCenter 2.5 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions of this document, see http://www.vmware.com/support/pubs. EN-000031-04 ESX Server 3 Configuration Guide You can find the most up-to-date technical documentation on the VMware Web site at: http://www.vmware.com/support/ The VMware Web site also provides the latest product updates. If you have comments about this documentation, submit your feedback to: [email protected]  Copyright © 2007–2010 VMware, Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. VMware products are covered by one or more patents listed at http://www.vmware.com/go/patents. VMware is a registered trademark or trademark of VMware, Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies. VMware, Inc. 3401 Hillview Ave. Palo Alto, CA 94304 www.vmware.com 2 VMware, Inc. Contents About This Book 9 1 Introduction 13 Networking 14 Storage 14 Security 15 Appendixes 15 Networking 2 Networking 19 Networking Concepts Overview 20 Virtual Switches 21 Port Groups 24 Enabling Network Services 24 Viewing Networking Information in the VI Client 25 Virtual Network Configuration for Virtual Machines 27 VMkernel Networking Configuration 30 TCP/IP Stack at the VMkernel Level 30 Implications and Guidelines for Configuration 31 Service Console Configuration 34 Basic Service Console Configuration Tasks 34 Using DHCP for the Service Console 39 3 Advanced Networking 41 Virtual Switch Properties and Policies 42 Virtual Switch Properties 42 Virtual Switch Policies 50 Port Group Configuration 58 DNS and Routing 61 VMware, Inc. 3 ESX Server 3 Configuration Guide TCP Segmentation Offload and Jumbo Frames 62 Enabling TSO 62 Enabling Jumbo Frames 64 NetQueue and Networking Performance 65 Setting Up MAC Addresses 67 MAC Addresses Generation 67 Setting MAC Addresses 68 Using MAC Addresses 69 Networking Best Practices and Tips 69 Networking Best Practices 69 Networking Tips 70 4 Networking Scenarios and Troubleshooting 73 Networking Configuration for Software iSCSI Storage 73 Configuring Networking on Blade Servers 78 Troubleshooting 81 Troubleshooting Service Console Networking 81 Troubleshooting Network Adapter Configuration 82 Troubleshooting Physical Switch Configuration 82 Troubleshooting Port Group Configuration 83 Storage 5 Introduction to Storage 87 Storage Overview 88 Types of Physical Storage 88 Local Storage 89 Networked Storage 90 Supported Storage Adapters 91 Datastores 91 VMFS Datastores 92 NFS Datastore 95 How Virtual Machines Access Storage 95 Comparing Types of Storage 97 Viewing Storage Information in the VMware Infrastructure Client Displaying Datastores 98 Viewing Storage Adapters 99 Understanding Storage Device Naming in the Display 100 Configuring and Managing Storage 101 4 97 VMware, Inc. Contents 6 Configuring Storage 103 Local Storage 104 Adding Local Storage 104 Fibre Channel Storage 107 Adding Fibre Channel Storage 108 iSCSI Storage 110 iSCSI Initiators 110 Naming Requirements 111 Discovery Methods 112 iSCSI Security 112 Configuring Hardware iSCSI Initiators and Storage 113 Configuring Software iSCSI Initiators and Storage 121 Performing a Rescan 126 Network Attached Storage 127 How Virtual Machines Use NFS 127 NFS Volumes and Virtual Machine Delegate Users 129 Configuring ESX Server 3 to Access NFS Volumes 129 Creating an NFS‐Based Datastore 129 Creating a Diagnostic Partition 130 7 Managing Storage 133 Managing Datastores 133 Editing VMFS Datastores 134 Upgrading Datastores 135 Changing the Names of Datastores 136 Adding Extents to Datastores 136 Managing Multiple Paths 137 Multipathing with Local Storage and Fibre Channel SANs 138 Multipathing with iSCSI SAN 140 Viewing the Current Multipathing Status 141 Setting Multipathing Policies for LUNs 143 Disabling Paths 144 The vmkfstools Commands 144 8 Raw Device Mapping 145 About Raw Device Mapping 145 Benefits of Raw Device Mapping 147 Limitations of Raw Device Mapping 149 VMware, Inc. 5 ESX Server 3 Configuration Guide Raw Device Mapping Characteristics 150 Virtual Compatibility Mode Compared to Physical Compatibility Mode 151 Dynamic Name Resolution 152 Raw Device Mapping with Virtual Machine Clusters 154 Comparing Raw Device Mapping to Other Means of SCSI Device Access 154 Managing Mapped LUNs 155 VMware Infrastructure Client 155 The vmkfstools Utility 158 File System Operations 159 Security 9 Security for ESX Server 3 Systems 163 ESX Server 3 Architecture and Security Features 164 Security and the Virtualization Layer 164 Security and Virtual Machines 165 Security and the Service Console 167 Security and the Virtual Networking Layer 169 Security Resources and Information 175 10 Securing an ESX Server 3 Configuration 177 Securing the Network with Firewalls 177 Firewalls for Configurations with a VirtualCenter Server 179 Firewalls for Configurations Without a VirtualCenter Server 182 TCP and UDP Ports for Management Access 183 Connecting to VirtualCenter Server Through a Firewall 185 Connecting to the Virtual Machine Console Through a Firewall 186 Connecting ESX Server 3 Hosts Through Firewalls 188 Opening Firewall Ports for Supported Services and Management Agents Securing Virtual Machines with VLANs 195 Security Considerations for vSwitches and VLANs 198 Virtual Switch Protection and VLANs 200 Securing Virtual Switch Ports 202 Securing iSCSI Storage 204 Securing iSCSI Devices Through Authentication 205 Protecting an iSCSI SAN 208 6 188 VMware, Inc. Contents 11 Authentication and User Management 211 Securing ESX Server 3 Through Authentication and Permissions 211 About Users, Groups, Permissions, and Roles 213 Working with Users and Groups on ESX Server 3 Hosts 219 Encryption and Security Certificates for ESX Server 3 225 Adding Certificates and Modifying ESX Server 3 Web Proxy Settings 227 Regenerating Certificates 231 Replacing Self‐Signed Certificates with CA‐Signed Certificates 231 Virtual Machine Delegates for NFS Storage 232 12 Service Console Security 235 General Security Recommendations 236 Logging On to the Service Console 237 Service Console Firewall Configuration 237 Changing the Service Console Security Level 238 Opening and Closing Ports in the Service Console Firewall 240 Password Restrictions 241 Password Aging 242 Password Complexity 244 Changing the Password Plug‐In 248 Cipher Strength 249 setuid and setgid Applications 250 Default setuid Applications 251 Default setgid Applications 252 SSH Security 253 Security Patches and Security Vulnerability Scanning Software 254 13 Security Deployments and Recommendations 257 Security Approaches for Common ESX Server 3 Deployments 257 Single Customer Deployment 257 Multiple Customer Restricted Deployment 259 Multiple Customer Open Deployment 261 Virtual Machine Recommendations 263 Installing Antivirus Software 263 Disabling Copy and Paste Operations Between the Guest Operating System and  Remote Console 263 Removing Unnecessary Hardware Devices 265 Limiting Guest Operating System Writes to Host Memory 267 Configuring Logging Levels for the Guest Operating System 270 VMware, Inc. 7 ESX Server 3 Configuration Guide Appendixes A ESX Server 3 Technical Support Commands 277 Other Commands 282 B Using vmkfstools 283 vmkfstools Command Syntax 283 vmkfstools Options 284 ‐v Suboption 285 File System Options 285 Virtual Disk Options 288 Managing SCSI Reservations of LUNs 294 Index 297 8 VMware, Inc. About This Book This book, the ESX Server 3 Configuration Guide, provides information on how to  configure networking for ESX Server 3, including how to create virtual switches and  ports and how to set up networking for virtual machines, VMotion, IP storage, and the  service console. It also discusses configuring file system and various types of storage  such as iSCSI, Fibre Channel, and so forth. To help you protect your ESX Server 3  installation, the guide provides a discussion of security features built into ESX Server 3  and the measures you can take to safeguard it from attack. In addition, it includes a list  of ESX Server 3 technical support commands along with their VI Client equivalents and  a description of the vmkfstools utility. The ESX Server 3 Configuration Guide covers ESX Server 3.5. To read about ESX Server 3i  version 3.5, see http://www.vmware.com/support/pubs/vi_pubs.html. For ease of discussion, this book uses the following product naming conventions:  For topics specific to ESX Server 3.5, this book uses the term “ESX Server 3.”   For topics specific to ESX Server 3i version 3.5, this book uses the term  “ESX Server 3i.”   For topics common to both products, this book uses the term “ESX Server.”  When the identification of a specific release is important to a discussion, this book  refers to the product by its full, versioned name.  When a discussion applies to all versions of ESX Server for VMware® Infrastructure 3,  this book uses the term “ESX Server 3.x.” VMware, Inc. 9 ESX Server 3 Configuration Guide Intended Audience This book is intended for anyone who wants to install, upgrade, or use ESX Server 3.  The information in this book is written for experienced Windows or Linux system  administrators who are familiar with virtual machine technology and datacenter  operations. Document Feedback VMware welcomes your suggestions for improving our documentation. If you have  comments, send your feedback to:  [email protected] VMware Infrastructure Documentation The VMware Infrastructure documentation consists of the combined VMware  VirtualCenter and ESX Server documentation set.  Abbreviations Used in Figures The figures in this book use the abbreviations listed in Table 1. Table 1. Abbreviations 10 Abbreviation Description database  VirtualCenter database datastore  Storage for the managed host dsk#  Storage disk for the managed host hostn  VirtualCenter managed hosts SAN Storage area network type datastore shared between managed hosts tmplt  Template user#  User with access permissions VC  VirtualCenter VM#  Virtual machines on a managed host VM Virtual machine VI Client VMware Infrastructure Client server VirtualCenter Server VMware, Inc. About This Book Technical Support and Education Resources The following sections describe the technical support resources available to you. To  access the current versions of this book and other books, go to: http://www.vmware.com/support/pubs. Online and Telephone Support Use online support to submit technical support requests, view your product and  contract information, and register your products. Go to: http://www.vmware.com/support Customers with appropriate support contracts should use telephone support for the  fastest response on priority 1 issues. Go to: http://www.vmware.com/support/phone_support.html Support Offerings Find out how VMware support offerings can help meet your business needs. Go to: http://www.vmware.com/support/services VMware Professional Services VMware Education Services courses offer extensive hands‐on labs, case study  examples, and course materials designed to be used as on‐the‐job reference tools.  Courses are available onsite, in the classroom, and live online. For onsite pilot  programs and implementation best practices, VMware Consulting Services provides  offerings to help you assess, plan, build, and manage your virtual environment. To  access information about education classes, certification programs, and consulting  services, go to http://www.vmware.com/services.  VMware, Inc. 11 ESX Server 3 Configuration Guide 12 VMware, Inc. 1 Introduction 1 The ESX Server 3 Configuration Guide describes the tasks you need to complete to  configure ESX Server 3 host networking, storage, and security. In addition, it provides  overviews, recommendations, and conceptual discussions to help you understand  these tasks and how to deploy an ESX Server 3 host to meet your needs. Before you use  the information in the ESX Server 3 Configuration Guide, read the Introduction to Virtual  Infrastructure for an overview of system architecture and the physical and virtual  devices that make up a VMware Infrastructure system. This introduction summarizes the contents of this guide so that you can find the  information you need. This guide discusses these subjects:   ESX Server 3 network configurations  ESX Server 3 storage configurations   ESX Server 3 security features  ESX Server 3 command reference  The vmkfstools command VMware, Inc. 13 ESX Server 3 Configuration Guide Networking The ESX Server 3 networking chapters provide you with a conceptual understanding  of physical and virtual network concepts, a description of the basic tasks you need to  complete to configure your ESX Server 3 host’s network connections, and a discussion  of advanced networking topics and tasks. The networking section contains the  following chapters:  Networking – Introduces you to network concepts and guides you through the  most common tasks you need to complete when setting up the network for the  ESX Server 3 host.   Advanced Networking – Discusses advanced networking tasks such as setting up  MAC addresses, editing virtual switches and ports, and DNS routing. In addition,  it provides tips on making your network configuration more efficient.  Networking Scenarios and Troubleshooting – Describes common networking  configuration and troubleshooting scenarios. Storage The ESX Server 3 storage chapters provide you with a basic understanding of storage,  a description of the basic tasks you perform to configure and manage your ESX Server 3  host’s storage, and a discussion of how to set up raw device mapping (RDM). The  storage section contains the following chapters: 14  Introduction to Storage – Introduces you to the types of storage you can configure  for the ESX Server 3 host.   Configuring Storage – Explains how to configure local SCSI storage, Fibre Channel  storage, and iSCSI storage. It also addresses virtual machine file system (VMFS)  storage and network‐attached storage.  Managing Storage – Explains how to manage existing datastores and the file  systems that comprise datastores.  Raw Device Mapping – Discusses raw device mapping, how to configure this type  of storage, and how to manage raw device mappings by setting up multipathing,  failover, and so forth. VMware, Inc. Chapter 1 Introduction Security The ESX Server 3 security chapters discuss safeguards that VMware has built into  ESX Server 3 and measures you can take to protect your ESX Server 3 host from  security threats. These measures include using firewalls, taking advantage of the  security features of virtual switches, and setting up user authentication and  permissions. The security section contains the following chapters:  Security for ESX Server 3 Systems – Introduces you to the ESX Server 3 features  that help you ensure a secure environment for your data and gives you an  overview of system design as it relates to security.  Securing an ESX Server 3 Configuration – Explains how to configure firewall ports  for ESX Server 3 hosts and VMware VirtualCenter, how to use virtual switches and  VLANs to ensure network isolation for virtual machines, and how to secure iSCSI  storage.  Authentication and User Management – Discusses how to set up users, groups,  permissions, and roles to control access to ESX Server 3 hosts and VirtualCenter. It  also discusses encryption and delegate users.  Service Console Security – Discusses the security features built into the service  console and shows you how to configure these features.  Security Deployments and Recommendations – Provides some sample  deployments to give you an idea of the issues you need to consider when you set  up your own ESX Server 3 deployment. This chapter also tells you about actions  you can take to further secure virtual machines. Appendixes The ESX Server 3 Configuration Guide includes appendixes that provide specialized  information you might find useful when configuring an ESX Server 3 host.  ESX Server 3 Technical Support Commands – Discusses the ESX Server 3  configuration commands that you can issue through a command‐line shell such as  secure shell (SSH). Although these commands are available for your use, do not  consider them to be an API that you can build scripts on. These commands are  subject to change and VMware does not support applications and scripts that rely  on ESX Server 3 configuration commands. This appendix provides you with  VMware Infrastructure Client equivalents for these commands.  Using vmkfstools – Discusses the vmkfstools utility, which you can use to  perform management and migration tasks for iSCSI disks. VMware, Inc. 15 ESX Server 3 Configuration Guide 16 VMware, Inc. Networking VMware, Inc. 17 ESX Server 3 Configuration Guide 18 VMware, Inc. 2 Networking 2 This chapter guides you through the basic concepts of networking in the ESX Server 3  environment and how to set up and configure a network in a virtual infrastructure  environment. Use the VMware Infrastructure (VI) Client to add networking based on three categories  that reflect the three types of network services:  Virtual machines  VMkernel  Service console This chapter discusses the following topics:  “Networking Concepts Overview” on page 20  “Enabling Network Services” on page 24  “Viewing Networking Information in the VI Client” on page 25  “Virtual Network Configuration for Virtual Machines” on page 27  “VMkernel Networking Configuration” on page 30  “Service Console Configuration” on page 34 VMware, Inc. 19 ESX Server 3 Configuration Guide Networking Concepts Overview A few concepts are essential to a thorough understanding of virtual networking. If you  are new to ESX Server 3, VMware recommends that you read this section. A physical network is a network of physical machines that are connected so that they can  send data to and receive data from each other. VMware ESX Server 3 runs on a physical  machine. A virtual network is a network of virtual machines running on a single physical machine  that are connected logically to each other so that they can send data to and receive data  from each other. Virtual machines can be connected to the virtual networks that you  create in the procedure to add a network. Each virtual network is serviced by a single  virtual switch. A virtual network can be connected to a physical network by associating  one or more physical Ethernet adapters, also referred to as uplink adapters, with the  virtual network’s virtual switch. If no uplink adapters are associated with the virtual  switch, all traffic on the virtual network is confined within the physical host machine.  If one or more uplink adapters are associated with the virtual switch, virtual machines  connected to that virtual network can also access the physical networks connected to  the uplink adapters. A physical Ethernet switch manages network traffic between machines on the physical  network. A switch has multiple ports, each of which can be connected to a single other  machine or another switch on the network. Each port can be configured to behave in  certain ways depending on the needs of the machine connected to it. The switch learns  which hosts are connected to which of its ports and uses that information to forward  traffic to the correct physical machines. Switches are the core of a physical network.  Multiple switches can be connected together to form larger networks. A virtual switch, vSwitch, works much like a physical Ethernet switch. It detects which  virtual machines are logically connected to each of its virtual ports and uses that  information to forward traffic to the correct virtual machines. A vSwitch can be  connected to physical switches by using physical Ethernet adapters, also referred to as  uplink adapters, to join virtual networks with physical networks. This type of  connection is similar to connecting physical switches together to create a larger  network. Even though a vSwitch works much like a physical switch, it does not have  some of the advanced functionality of a physical switch. See “Virtual Switches” on  page 21. A port group specifies port configuration options such as bandwidth limitations and  VLAN tagging policies for each member port. Network services connect to vSwitches  through port groups. Port groups define how a connection is made through the vSwitch  to the network. In typical use, one or more port groups is associated with a single  vSwitch. See “Port Groups” on page 24. 20 VMware, Inc. Chapter 2 Networking NIC teaming occurs when multiple uplink adapters are associated with a single vSwitch  to form a team. A team can either share the load of traffic between physical and virtual  networks among some or all of its members, or provide passive failover in the event of  a hardware failure or a network outage. VLANs enable a single physical LAN segment to be further segmented so that groups  of ports are isolated from one another as if they were on physically different segments.  The standard is 802.1Q. The VMkernel TCP/IP networking stack supports iSCSI, NFS, and VMotion. Virtual  machines run their own systems’ TCP/IP stacks, and connect to the VMkernel at the  Ethernet level through virtual switches. Two new features in ESX Server 3, iSCSI and  NFS, are referred to as IP storage in this chapter. IP storage refers to any form of storage  that uses TCP/IP network communication as its foundation. iSCSI can be used as a  virtual machine datastore, and NFS can be used as a virtual machine datastore and for  direct mounting of .ISO files, which are presented as CD‐ROMs to virtual machines. NOTE   The networking chapters discuss how to set up networking for iSCSI and NFS.  To configure the storage portion of iSCSI and NFS, see the storage chapters. TCP Segmentation Offload, TSO, allows a TCP/IP stack to emit very large frames (up  to 64KB) even though the maximum transmission unit (MTU) of the interface is smaller.  The network adapter then separates the large frame into MTU‐sized frames and  prepends an adjusted copy of the initial TCP/IP headers. See “TCP Segmentation  Offload and Jumbo Frames” on page 62. Migration with VMotion enables a virtual machine that is powered on to be transferred  from one ESX Server 3 host to another without shutting down the virtual machine. The  optional VMotion feature requires its own license key. Virtual Switches VMware Infrastructure lets you use the Virtual Infrastructure (VI) Client or direct SDK  APIs to create abstracted network devices called virtual switches (vSwitches). A  vSwitch can route traffic internally between virtual machines and link to external  networks. NOTE   You can create a maximum of 127 vSwitches on a single host. Use virtual switches to combine the bandwidth of multiple network adapters and  balance communications traffic among them. They can also be configured to handle  physical NIC failover. VMware, Inc. 21 ESX Server 3 Configuration Guide A vSwitch models a physical Ethernet switch. The default number of logical ports for a  vSwitch is 56. However, a vSwitch can be created with up to 1016 ports in ESX Server 3.  You can connect one network adapter of a virtual machine to each port. Each uplink  adapter associated with a vSwitch uses one port. Each logical port on the vSwitch is a  member of a single port group. Each vSwitch can also have one or more port groups  assigned to it. See “Port Groups” on page 24. Before you can configure virtual machines to access a network, you must perform the  following tasks: 1 Create a vSwitch, and configure it to connect to the physical adapters on the host  for the required physical network. 2 Create a virtual machine port group connected to that vSwitch, and give it a name  that will be referenced by the virtual machine configuration. When two or more virtual machines are connected to the same vSwitch, network traffic  between them is routed locally. If an uplink adapter is attached to the vSwitch, each  virtual machine can access the external network that the adapter is connected to, as  shown in Figure 2‐1. Figure 2-1. Virtual Switch Connections 22 VMware, Inc. Chapter 2 Networking In the VI Client, the details for the selected vSwitch are presented as an interactive  diagram as shown in Figure 2‐2. The most important information for each vSwitch is  always visible. Figure 2-2. Virtual Switch Interactive Diagram info icon Click the info icon to selectively reveal secondary and tertiary information. VMware, Inc. 23 ESX Server 3 Configuration Guide A pop‐up window displays detailed properties, as shown in Figure 2‐3. Figure 2-3. Virtual Switch Detailed Properties Port Groups Port groups aggregate multiple ports under a common configuration and provide a  stable anchor point for virtual machines connecting to labeled networks. Each port  group is identified by a network label, which is unique to the current host. NOTE   You can create a maximum of 512 port groups on a single host. A VLAN ID, which restricts port group traffic to a logical Ethernet segment within the  physical network, is optional. NOTE   For a port group to reach port groups located on other VLANs, set the VLAN ID  to 4095. Enabling Network Services You need to enable two types of network services in ESX Server 3: 24  Connecting virtual machines to the physical network  Connecting VMkernel services (such as NFS, iSCSI, or VMotion) to the physical  network VMware, Inc. Chapter 2 Networking Networking for the service console, which runs management services for ESX Server 3,  is set up by default during installation. A service console port is required for  ESX Server 3 to connect to any network or remote services, including the VI Client.  Additional service console ports might be necessary for certain services, such as iSCSI  storage. For information on configuring service console ports, see “Service Console  Configuration” on page 34. Viewing Networking Information in the VI Client The VI Client displays general networking information and information specific to  network adapters. To view general networking information in the VI Client 1 Log in to the VI Client and select the server from the inventory panel.  The hardware configuration page for this server appears. 2 Click the Configuration tab and click Networking.  The networking panel displays the following information, as shown in Figure 2‐4:  Virtual switches  Adapter information for each adapter   Link status   Apparent speed and duplex Service console and VMkernel TCP/IP services IP address   Service console Virtual device name   VMware, Inc. Virtual machines  Power status  Connection status Port group  Network label – common to all three port configuration types  Number of configured virtual machines   VLAN ID, if any – common to all three port configuration types  25 ESX Server 3 Configuration Guide Figure 2-4. General Networking Information port group IP address virtual machine network properties pop-up menu vSwitch network adapter To view network adapter information in the VI Client 1 Log in to the VI Client and select the server from the inventory panel.  The hardware configuration page for this server appears. 2 Click the Configuration tab, and click Network Adapters. The network adapters panel displays the following information: 26  Device – Name of the network adapter  Speed – Actual speed and duplex of the network adapter  Configured – Configured speed and duplex of the network adapter  vSwitch – vSwitch that the network adapter is associated with  Observed IP ranges – IP addresses that the network adapter has access to  Wake on LAN supported – Network adapter ability to support Wake on LAN VMware, Inc. Chapter 2 Networking Virtual Network Configuration for Virtual Machines The VI Client Add Network wizard guides you through the tasks to create a virtual  network to which virtual machines can connect. These tasks include:  Setting the connection type for a virtual machine  Adding the virtual network to a new or an existing vSwitch  Configuring the connection settings for the network label and the VLAN ID For information on configuring network connections for an individual virtual machine,  see the Basic System Administration Guide. When you set up virtual machine networks, consider whether you want to migrate the  virtual machines in the network between ESX Server 3 hosts. If so, be sure that both  hosts are in the same broadcast domain—that is, the same Layer 2 subnet.  ESX Server 3 doesn’t support virtual machine migration between hosts in different  broadcast domains because the migrated virtual machine might require systems and  resources that it would no longer have access to by virtue of being moved to a separate  network. Even if your network configuration is set up as a high‐availability  environment, or includes intelligent switches that can resolve the virtual machine’s  needs across different networks, you might experience lag times as the Address  Resolution Protocol (ARP) table updates and resumes network traffic for the virtual  machines. Virtual machines reach physical networks through uplink adapters. A vSwitch can  transfer data to external networks only when one or more network adapters are  attached to it. When two or more adapters are attached to a single vSwitch, they are  transparently teamed. VMware, Inc. 27 ESX Server 3 Configuration Guide To create or add a virtual network for a virtual machine 1 Log in to the VI Client and select the server from the inventory panel.  The hardware configuration page for this server appears. 2 Click the Configuration tab and click Networking.  Virtual switches appear in an overview that includes a details layout. 3 On the right side of the page, click Add Networking. NOTE   You use the Add Network wizard is to add new ports and port groups. 4 Accept the default connection type, Virtual Machines. Virtual Machines lets you add a labeled network to handle virtual machine  network traffic. 5 Click Next. 6 Select Create a virtual switch. You can create a new vSwitch with or without Ethernet adapters. If you create a vSwitch without physical network adapters, all traffic on that  vSwitch is confined to that vSwitch. No other hosts on the physical network or  virtual machines on other vSwitches can send or receive traffic over this vSwitch.  You might create a vSwitch without physical network adapters if you want a group  of virtual machines to be able to communicate with each other, but not with other  hosts or with virtual machines outside the group. Changes appear in the Preview pane. 7 28 Click Next. VMware, Inc. Chapter 2 Networking 8 In the Port Group Properties group, enter a network label that identifies the port  group that you are creating. Use network labels to identify migration‐compatible connections common to two  or more hosts. 9 If you are using a VLAN, in the VLAN ID field, enter a number between 1 and  4094.  If you are unsure what to enter, leave this field blank or ask your network  administrator. If you enter 0 or leave the field blank, the port group can see only untagged  (non‐VLAN) traffic. If you enter 4095, the port group can see traffic on any VLAN  while leaving the VLAN tags intact. 10 Click Next. 11 After you determine that the vSwitch is configured correctly, click Finish. NOTE   To enable failover (NIC teaming), bind two or more adapters to the same  switch. If one uplink adapter is not operational, network traffic is routed to another  adapter attached to the switch. NIC teaming requires both Ethernet devices to be  on the same Ethernet broadcast domain. VMware, Inc. 29 ESX Server 3 Configuration Guide VMkernel Networking Configuration Moving a virtual machine from one host to another is called migration. Migrating a  virtual machine that is powered on is called VMotion. Migration with VMotion,  designed to be used between highly compatible systems, lets you migrate virtual  machines with no downtime. Your VMkernel networking stack must be set up properly  to accommodate VMotion. IP Storage refers to any form of storage that uses TCP/IP network communication as its  foundation, which includes iSCSI and NFS for ESX Server 3. Because both of these  storage types are network based, both types can use the same VMkernel interface and  port group. The network services that the VMkernel (iSCSI, NFS, and VMotion) provides use a  TCP/IP stack in the VMkernel. This TCP/IP stack is completely separate from the  TCP/IP stack used in the service console. Each of these TCP/IP stacks accesses various  networks by attaching to one or more port groups on one or more vSwitches. TCP/IP Stack at the VMkernel Level The VMware VMkernel TCP/IP networking stack has been extended to handle iSCSI,  NFS, and VMotion in the following ways:  iSCSI as a virtual machine datastore  iSCSI for the direct mounting of .ISO files, which are presented as CD‐ROMs to  virtual machines  NFS as a virtual machine datastore  NFS for the direct mounting of .ISO files, which are presented as CD‐ROMs to  virtual machines  Migration with VMotion NOTE   ESX Server 3 supports only NFS version 3 over TCP/IP. 30 VMware, Inc. Chapter 2 Networking Implications and Guidelines for Configuration Refer to the following guidelines when you configure VMkernel networking:  The IP address that you assign to the service console during installation must be  different from the IP address that you assign to the VMkernel’s TCP/IP stack from  the Configuration > Networking tab of the VMware Infrastructure Client.  Unlike other VMkernel services, iSCSI has a service console component, so  networks that are used to reach iSCSI targets must be accessible to both service  console and VMkernel TCP/IP stacks.  Before you configure a software iSCSI for the ESX Server 3 host, open a firewall  port by enabling the iSCSI software client service. See “Opening Firewall Ports for  Supported Services and Management Agents” on page 188. To set up the VMkernel 1 Log in to the VMware VI Client and select the server from the inventory panel.  The hardware configuration page for this server appears. 2 Click the Configuration tab and click Networking.  3 Click Add Networking. 4 Select VMkernel and click Next. Selecting VMotion and IP Storage lets you connect the VMkernel, which runs  services for VMotion and IP storage (NFS or iSCSI), to the physical network. The Network Access page appears. 5 Select the vSwitch to use, or select Create a virtual switch to create a new vSwitch. VMware, Inc. 31 ESX Server 3 Configuration Guide 6 Select the check boxes for the network adapters your vSwitch will use. Your choices appear in the Preview pane. Select adapters for each vSwitch so that virtual machines or other services that  connect through the adapter can reach the correct Ethernet segment. If no adapters  appear under Create a new virtual switch, all the network adapters in the system  are being used by existing vSwitches. You can either create a new vSwitch without  a network adapter, or select a network adapter that an existing vSwitch uses. For information on moving network adapters between vSwitches, see “To add  uplink adapters” on page 45. 32 7 Click Next. 8 In the Port Group Properties area, select or enter a network label and a VLAN ID.  Network Label — A name that identifies the port group that you are creating.  This is the label that you specify when configuring a virtual adapter to be  attached to this port group, when configuring VMkernel services, such as  VMotion and IP storage.  VLAN ID — Identifies the VLAN that the port group’s network traffic will  use. VMware, Inc. Chapter 2 Networking 9 Select Use this port group for VMotion to enable this port group to advertise itself  to another ESX Server as the network connection where VMotion traffic should be  sent. You can enable this property for only one VMotion and IP storage port group for  each ESX Server 3 host. If this property is not enabled for any port group,  migration with VMotion to this host is not possible. 10 In the IP Settings group, click Edit to set the VMkernel Default Gateway for  VMkernel services, such as VMotion, NAS, and iSCSI. NOTE   Set a default gateway for the port that you created. VirtualCenter 2 behaves  differently from VirtualCenter 1.x. You must use a valid IP address to configure the  VMkernel IP stack, not a dummy address. On the DNS Configuration tab, the name of the host is entered into the name field  by default. The DNS server addresses that were specified during installation are  also preselected, as is the domain. On the Routing tab, the service console and the VMkernel each need their own  gateway information. A gateway is needed if connectivity to machines not on the  same IP subnet as the service console or VMkernel. Static IP settings is the default. VMware, Inc. 33 ESX Server 3 Configuration Guide 11 Click OK, then click Next. 12 Use the Back button to make any changes. 13 Review your changes on the Ready to Complete page and click Finish. Service Console Configuration The service console and the VMkernel use virtual Ethernet adapters to connect to a  vSwitch and to reach networks that the vSwitch services. Basic Service Console Configuration Tasks Two common service console configuration changes are: changing NICs and changing  the settings for an existing NIC that is in use. When only one service console connection is present, changing the service console  configuration is not allowed. For a new connection, change the network settings to use  an additional NIC. After you verify that the new connection is functioning properly,  remove the old connection. You are switching over to the new NIC. NOTE   You can create a maximum of 16 service console ports in ESX Server 3. To configure service console networking 1 Log in to the VI Client and select the server from the inventory panel.  The hardware configuration page for this server appears. 34 2 Click the Configuration tab, and click Networking.  3 Click Add Networking. VMware, Inc. Chapter 2 Networking 4 Select Service Console on the Connection Types page, and click Next. 5 Select the vSwitch to use for network access, or select Create a new vSwitch and  click Next. If no adapters appear in the Create a new virtual switch group, all the network  adapters in the system are being used by existing vSwitches. For information on  moving network adapters between vSwitches, see “To add uplink adapters” on  page 45. VMware, Inc. 35 ESX Server 3 Configuration Guide 6 In the Port Group Properties group, select or enter the Network Label and  VLAN ID. Newer ports and port groups appear at the top of the vSwitch diagram. 7 Enter the IP Address and Subnet Mask, or select Obtain IP setting automatically  for the IP address and subnet mask. 8 Click Edit to set the Service Console Default Gateway. See “To set the default gateway” on page 37. 9 Click Next. 10 Check the information and click Finish. To configure service console ports 1 Log in to the VI Client and select the server from the inventory panel.  The hardware configuration page for this server appears. 36 2 Click the Configuration tab, and click Networking.  3 On the right side of the page, find the vSwitch to edit and click Properties for that  vSwitch.  VMware, Inc. Chapter 2 Networking 4 In the vSwitch Properties dialog box, click the Ports tab. 5 Select Service Console, and click Edit. A warning dialog box appears to explain that modifying your service console  connection might disconnect all management agents. 6 To continue with the service console configuration, click Continue modifying this  connection. 7 Edit port properties, IP settings, and effective policies as necessary. 8 Click OK. Only one default gateway can be configured per TCP/IP stack. To set the default gateway 1 Log into the VMware VI Client and select the server from the inventory panel.  The hardware configuration page for this server appears. 2 Click the Configuration tab, and click DNS and Routing. The DNS and Routing panel appears. 3 Click Properties. On the DNS Configuration tab, the name of the host is entered into the name field  by default. The DNS server addresses and the domain previously selected during  installation are also preselected. On the Routing tab, the service console and the VMkernel are often not connected  to the same network, and each needs its own gateway information. A gateway is  needed for connectivity to machines not on the same IP subnet as the service  console or VMkernel interfaces. NOTE   All NAS and iSCSI servers need to be either reachable by the default  gateway, or on the same broadcast domain as the associated vSwitches. For the service console, the gateway device is needed only when two or more  network adapters are using the same subnet. The gateway device determines  which network adapter will be used for the default route. VMware, Inc. 37 ESX Server 3 Configuration Guide 4 Click the Routing tab. 5 Set the VMkernel default gateway. CAUTION   There is a risk of misconfiguration, which can cause the UI to lose  connectivity to the host, in which case the host will have to be reconfigured from  command line at the service console. Be sure that your network settings are correct  before saving your changes. 6 Click OK. To display service console information 1 Click the info icon to display service console information.  info icon 2 38 Click the X to close the information pop‐up window. VMware, Inc. Chapter 2 Networking Using DHCP for the Service Console In most cases, use static IP addresses for the service console. You can also set up the  service console to use dynamic addressing, DHCP, if your DNS server can map the  service console’s host name to the dynamically generated IP address. If your DNS server cannot map the host’s name to its DHCP‐generated IP address,  determine the service console’s numeric IP address and use that numeric address when  accessing the host. The numeric IP address might change as DHCP leases expire or when the system is  rebooted. For this reason, VMware does not recommend using DHCP for the service  console unless your DNS server can handle the host name translation. VMware, Inc. 39 ESX Server 3 Configuration Guide 40 VMware, Inc. 3 Advanced Networking 3 This chapter guides you through advanced networking topics in an ESX Server 3  environment, and reviews how to set up and change advanced networking  configuration options. This chapter discusses the following topics:  “Virtual Switch Properties and Policies” on page 42  “Port Group Configuration” on page 58  “DNS and Routing” on page 61  “TCP Segmentation Offload and Jumbo Frames” on page 62  “NetQueue and Networking Performance” on page 65  “Setting Up MAC Addresses” on page 67  “Networking Best Practices and Tips” on page 69 VMware, Inc. 41 ESX Server 3 Configuration Guide Virtual Switch Properties and Policies This section guides you through configuring virtual switch properties and networking  policies set at the virtual switch level. Virtual Switch Properties Virtual switch settings control vSwitch‐wide defaults for ports, which can be  overridden by port group settings for each vSwitch. Editing Virtual Switch Properties Editing vSwitch properties consists of:  Configuring ports  Configuring the uplink network adapters To edit the number of ports for a vSwitch 1 Log in to the VI Client, and select the server from the inventory panel.  The hardware configuration page for this server appears. 2 42 Click the Configuration tab, and click Networking.  VMware, Inc. Chapter 3 Advanced Networking 3 On the right side of the page, find the vSwitch to edit.  4 Click Properties for that vSwitch.  5 Click the Ports tab. 6 Select the vSwitch item in the Configuration list, and click Edit. 7 Click the General tab to set the number of ports. 8 Choose the number of ports you want to use from the drop‐down menu. 9 Click OK. To configure the uplink network adapter by changing its speed 1 Log in to the VI Client and select the server from the inventory panel.  The hardware configuration page for this server appears. 2 Click the Configuration tab, and click Networking.  3 Select a vSwitch and click Properties. VMware, Inc. 43 ESX Server 3 Configuration Guide 4 Click the Network Adapters tab.  5 To change the configured speed and duplex value of a network adapter, select the  network adapter and click Edit. The Status dialog box appears. The default is Autonegotiate, which is usually the  correct choice. 44 VMware, Inc. Chapter 3 Advanced Networking 6 To select the connection speed manually, select the speed/duplex from the  drop‐down menu.  Choose the connection speed manually if the NIC and a physical switch might fail  to negotiate the proper connection speed. Symptoms of mismatched speed and  duplex include low bandwidth or no link connectivity at all. The adapter and the physical switch port it is connected to must be set to the same  value, that is, auto and auto or ND and ND where ND is some speed and duplex,  but not auto and ND. 7 Click OK. To add uplink adapters 1 Log in to the VI Client, and select the server from the inventory panel.  The hardware configuration page for this server appears. 2 Click the Configuration tab and click Networking.  3 Select a vSwitch and click Properties. 4 In the Properties dialog box, click the Network Adapters tab.  VMware, Inc. 45 ESX Server 3 Configuration Guide 5 Click Add to launch the Add Adapter wizard. You can associate multiple adapters to a single vSwitch to provide NIC teaming.  Such a team can share traffic and provide failover. CAUTION   Misconfiguration can result in the loss of the VI Client ability to connect  to the host. 6 46 Select one or more adapters from the list and click Next. VMware, Inc. Chapter 3 Advanced Networking 7 To order the NICs, select a NIC and click Move Up and Move Down to move it up  or down into the appropriate category (Active or Standby).  Active Adapters — Adapters that the vSwitch uses.  Standby Adapters — Adapters that become active if one or more of the active  adapters fails. 8 Click Next. 9 Review the information on the Adapter Summary page, click Back to change any  entries, and click Finish. The list of network adapters reappears, showing the adapters that the vSwitch now  claims. 10 Click Close to exit the vSwitch Properties dialog box. The Networking section in the Configuration tab shows the network adapters in  their designated order and categories. VMware, Inc. 47 ESX Server 3 Configuration Guide Cisco Discovery Protocol Cisco Discovery Protocol (CDP) allows ESX Server 3 administrators to determine  which Cisco switch port is connected to a given vSwitch. When CDP is enabled for a  particular vSwitch, you can view properties of the Cisco switch (such as device ID,  software version, and timeout) from the VI Client. You can use the service console command‐line interface to enable CDP. To enable CDP 1 Log in directly to your ESX Server 3 hostʹs console. 2 Use the esxcfg-vswitch -b  command to view the current CDP  mode for the vSwitch. If CDP is disabled, the mode will be shown as down. 3 Use the esxcfg-vswitch -B  command to change the CDP  mode. The available CDP modes are:  down – CDP is disabled.  listen — ESX Server 3 detects and displays information about the associated  Cisco switch port, but information about the vSwitch is not available to the  Cisco switch administrator.  advertise – ESX Server 3 makes information about the vSwitch available to the  Cisco switch administrator, but does not detect and display information about  the Cisco switch  both – ESX Server 3 detects and displays information about the associated  Cisco switch and makes information about the vSwitch available to the Cisco  switch administrator. To view Cisco switch information from the VI Client 1 Set the CDP mode for the vSwitch to either both or listen. 2 Log in to the VI Client, and select the server from the inventory panel.  The hardware configuration page for this server appears. 48 VMware, Inc. Chapter 3 Advanced Networking 3 VMware, Inc. Click the Configuration tab, and click Networking. 49 ESX Server 3 Configuration Guide 4 Click the info icon to the right of the vSwitch. NOTE   Because the CDP advertisements of Cisco equipment typically occur once a  minute, a noticeable delay might occur between enabling CDP on ESX Server 3 and the  availability of CDP data from the VI client. Virtual Switch Policies You can apply a set of vSwitch‐wide policies by selecting the vSwitch at the top of the  Ports tab and clicking Edit.  To override any of these settings for a port group, select that port group and click Edit.  Any changes to the vSwitch‐wide configuration are applied to any of the port groups  on that vSwitch, except for the configuration options that are overridden by the port  group. 50 VMware, Inc. Chapter 3 Advanced Networking The vSwitch policies consist of:  Layer 2 Security policy  Traffic Shaping policy  Load Balancing and Failover policy Layer 2 Security Policy Layer 2 is the data link layer. The three elements of the Layer 2 Security policy are  promiscuous mode, MAC address changes, and forged transmits. In nonpromiscuous mode, a guest adapter listens to traffic only on its own MAC  address. In promiscuous mode, it can listen to all the packets. By default, guest adapters  are set to non‐promiscuous mode.  For further information on security, see “Securing Virtual Switch Ports” on page 202.  To edit the Layer 2 Security policy 1 Log into the VMware VI Client and select the server from the inventory panel.  The hardware configuration page for this server appears. 2 Click the Configuration tab, and click Networking.  3 Click Properties for the vSwitch whose Layer 2 Security policy you want to edit. 4 In the Properties dialog box for the vSwitch, click the Ports tab. 5 Select the vSwitch item and click Edit. 6 In the Properties dialog box for the vSwitch, click the Security tab. VMware, Inc. 51 ESX Server 3 Configuration Guide By default, Promiscuous Mode is set to Reject, MAC Address Changes, and  Forced Transmits are set to Accept. The policy here applies to all virtual adapters on the vSwitch except where the port  group for the virtual adapter specifies a policy exception. 7 In the Policy Exceptions pane, select whether to reject or accept the Layer2 Security  policy exceptions:   Promiscuous Mode  Reject — Placing a guest adapter in promiscuous mode has no effect on  which frames are received by the adapter.  Accept — Placing a guest adapter in promiscuous mode causes it to  detect all frames passed on the vSwitch that are allowed under the VLAN  policy for the port group that the adapter is connected to. MAC Address Changes  Reject — If you set the MAC Address Changes to Reject and the guest  operating system changes the MAC address of the adapter to anything  other than what is in the .vmx configuration file, all inbound frames are  dropped. If the Guest OS changes the MAC address back to match the MAC  address in the .vmx configuration file, inbound frames are passed again.   8 52 Accept — Changing the MAC address from the Guest OS has the  intended effect: frames to the new MAC address are received. Forged Transmits  Reject — Any outbound frame with a source MAC address that is  different from the one currently set on the adapter are dropped.   Accept — No filtering is performed and all outbound frames are passed. Click OK. VMware, Inc. Chapter 3 Advanced Networking Traffic Shaping Policy ESX Server 3 shapes traffic by establishing parameters for three outbound traffic  characteristics: average bandwidth, burst size, and peak bandwidth. You can set values  for these characteristics through the VI Client, establishing a traffic shaping policy for  each port group.   Average Bandwidth establishes the number of bits per second to allow across the  vSwitch averaged over time—the allowed average load.  Burst Size establishes the maximum number of bytes to allow in a burst. If a burst  exceeds the burst size parameter, excess packets are queued for later transmission.  If the queue is full, the packets are dropped. When you specify values for these two  characteristics, you indicate what you expect the vSwitch to handle during normal  operation.  Peak Bandwidth is the maximum bandwidth the vSwitch can absorb without  dropping packets. If traffic exceeds the peak bandwidth that you establish, excess  packets are queued for later transmission after traffic on the connection returns to  the average and enough spare cycles are available to handle the queued packets. If  the queue is full, the packets are dropped. Even if you have spare bandwidth  because the connection has been idle, the peak bandwidth parameter limits  transmission to no more than peak until traffic returns to the allowed average load.  To edit the Traffic Shaping policy 1 Log in to the VI Client and select the server from the inventory panel.  The hardware configuration page for this server appears. 2 Click the Configuration tab, and click Networking.  3 Select a vSwitch and click Properties. 4 In the vSwitch Properties dialog box, click the Ports tab. 5 Select the vSwitch and click Edit. VMware, Inc. 53 ESX Server 3 Configuration Guide 6 Click the Traffic Shaping tab. When traffic shaping is disabled, the tunable features are dimmed. You can  selectively override all traffic‐shaping features at the port group level if traffic  shaping is enabled. This policy is applied to each individual virtual adapter attached to the port group,  not to the vSwitch as a whole. Status — If you enable the policy exception in the Status field, you are setting  limits on the amount of networking bandwidth allocation for each virtual adapter  associated with this particular port group. If you disable the policy, services have  a free, clear connection to the physical network by default. The remaining fields define network traffic parameters: 54  Average Bandwidth is a value measured over a particular period of time.  Peak Bandwidth is a value that is the maximum bandwidth allowed and that  can never be smaller than average bandwidth. This parameter limits the  maximum bandwidth during a burst.  Burst Size is a value that specifies how large a burst can be in kilobytes (KB).  This parameter controls the amount of data that can be sent in one burst.  VMware, Inc. Chapter 3 Advanced Networking Load Balancing and Failover Policy Load Balancing and Failover policies allow you to determine how network traffic is  distributed between adapters and how to re‐route traffic in the event of an adapter  failure by configuring the following parameters:  Load Balancing policy determines how outgoing traffic is distributed among the  network adapters assigned to a vSwitch. NOTE   Incoming traffic is controlled by the Load Balancing policy on the physical  switch.  Failover Detection: Link Status and Beacon Probing  Network Adapter Order (Active or Standby) To edit the failover and load balancing policy 1 Log in to the VI Client and select the server from the inventory panel.  The hardware configuration page for this server appears. 2 Click the Configuration tab, and click Networking.  3 Select a vSwitch and click Edit. 4 In the vSwitch Properties dialog box, click the Ports tab. 5 To edit the Failover and Load Balancing values for the vSwitch, select the vSwitch  item and click Properties. VMware, Inc. 55 ESX Server 3 Configuration Guide 6 Click the NIC Teaming tab. You can override the failover order at the port group level. By default, new  adapters are active for all policies. New adapters carry traffic for the vSwitch and  its port group unless you specify otherwise. 7 In the Policy Exceptions group:  56 Load Balancing — Specify how to choose an uplink.  Route based on the originating port ID — Choose an uplink based on the  virtual port where the traffic entered the virtual switch.  Route based on ip hash — Choose an uplink based on a hash of the  source and destination IP addresses of each packet. For non‐IP packets,  whatever is at those offsets is used to compute the hash. VMware, Inc. Chapter 3 Advanced Networking  Route based on source MAC hash — Choose an uplink based on a hash  of the source Ethernet.  Use explicit failover order — Always use the highest order uplink from  the list of Active adapters which passes failover detection criteria. NOTE   IP‐based teaming requires that the physical switch be configured with  etherchannel. For all other options, etherchannel should be disabled.   Network Failover Detection — Specify the method to use for failover  detection.  Link Status only – Relies solely on the link status that the network  adapter provides. This option detects failures, such as cable pulls and  physical switch power failures, but not configuration errors, such as a  physical switch port being blocked by spanning tree or that is  misconfigured to the wrong VLAN or cable pulls on the other side of a  physical switch.  Beacon Probing – Sends out and listens for beacon probes on all NICs in  the team and uses this information, in addition to link status, to  determine link failure. This detects many of the failures previously  mentioned that are not detected by link status alone. Notify Switches — Select Yes or No to notify switches in the case of failover. If you select Yes, whenever a virtual NIC is connected to the vSwitch or  whenever that virtual NIC’s traffic would be routed over a different physical  NIC in the team because of a failover event, a notification is sent out over the  network to update the lookup tables on physical switches. In almost all cases,  this process is desirable for the lowest latency of failover occurrences and  migrations with VMotion. NOTE   Do not use this option when the virtual machines using the port group  are using Microsoft Network Load Balancing in unicast mode. No such issue  exists with NLB running in multicast mode.  Failback — Select Yes or No to disable or enable failback. This option determines how a physical adapter is returned to active duty after  recovering from a failure. If failback is set to Yes (default), the adapter is  returned to active duty immediately upon recovery, displacing the standby  adapter that took over its slot, if any. If failback is set to No, a failed adapter is  left inactive even after recovery until another currently active adapter fails,  requiring its replacement. VMware, Inc. 57 ESX Server 3 Configuration Guide  Failover Order — Specify how to distribute the work load for adapters. If you  want to use some adapters but reserve others for emergencies in case the  adapters in use fail, set this condition by using the drop‐down menu to place  them into the two groups:  Active Adapters — Continue to use the adapter when the network  adapter connectivity is up and active.  Standby Adapters — Use this adapter if one of the active adapter’s  connectivity is down.  Unused Adapters — Not to be used. Port Group Configuration You can change the following port group configurations:  Port group properties  Labelled network policies To edit port group properties 1 Log into the VMware VI Client, and select the server from the inventory panel.  The hardware configuration page for this server appears. 2 Click the Configuration tab, and click Networking.  3 On the right side of the window, click Properties for a network.  4 Click the Ports tab. 5 Select the port group and click Edit. 6 In the Properties dialog box for the port group, click the General tab to change: 7 58  Network Label — Identifies the port group that you are creating. Specify this  label when you configure a virtual adapter to be attached to this port group,  either when you configure virtual machines or when you configure VMkernel  services, such as VMotion and IP storage.  VLAN ID — Identifies the VLAN that the port group’s network traffic will  use. Click OK. VMware, Inc. Chapter 3 Advanced Networking To override labeled network policies 1 To override any network policies for a particular labeled network, select the  network, click Edit, and click the Security tab. 2 Select the check box for the labeled network policy to override. For information on these settings, see “Layer 2 Security Policy” on page 51. 3 Click the Traffic Shaping tab. 4 Select the check box next to Status and select Enabled or Disabled. For information on the Status settings, see “Traffic Shaping Policy” on page 53. VMware, Inc. 59 ESX Server 3 Configuration Guide 5 Click the NIC Teaming tab. 6 Select the associated check box to override the load balancing or failover order  policies. For information on these settings, see “Load Balancing and Failover Policy” on  page 55. 7 60 Click OK. VMware, Inc. Chapter 3 Advanced Networking DNS and Routing Configure DNS and routing through the VI Client. To change the DNS and routing configuration 1 Log in to the VI Client and select the server from the inventory panel.  The hardware configuration page for this server appears. 2 Click the Configuration tab, and click DNS and Routing. 3 On the right of the window, click Properties. 4 In the DNS Configuration tab, enter values for the Name and Domain fields. 5 Choose to obtain the DNS server address automatically or use a DNS server  address. NOTE   DHCP is supported only if the DHCP server is accessible to the service  console. In other words, the service console must have a virtual interface (vswif)  configured and attached to the network where the DHCP server resides. 6 VMware, Inc. Specify the domains in which to look for hosts. 61 ESX Server 3 Configuration Guide 7 On the Routing tab, change default gateway information as needed. Select a gateway device only if you have configured the service console to connect  to more than one subnet. 8 Click OK. TCP Segmentation Offload and Jumbo Frames TCP Segmentation Offload (TSO) and Jumbo Frame support are added to the TCP/IP  stack in ESX Server 3 version 3.5. Jumbo Frames must be enabled at the server level  using the command‐line interface to configure the MTU size for each vSwitch. TSO is  enabled on the VMkernel interface by default, but must be enabled at the virtual  machine level. Enabling TSO TSO support through the Enhanced vmxnet network adapter is available for virtual  machines running the following guest operating systems: 62  Microsoft Windows 2003 Enterprise Edition with Service Pack 2 (32‐bit and 64‐bit)  Red Hat Enterprise Linux 4 (64‐bit) VMware, Inc. Chapter 3 Advanced Networking  Red Hat Enterprise Linux 5 (32‐bit and 64‐bit)  SuSE Linux Enterprise Server 10 (32‐bit and 64‐bit) To enable TSO at the virtual machine level, you must replace the existing vmxnet or  Flexible virtual network adapters with Enhanced vmxnet virtual network adapters.  This may result in a change in the MAC address of the virtual network adapter. To enable TSO support for a virtual machine 1 Log in to the VI Client and select the virtual machine from the inventory panel.  The hardware configuration page for this server appears. 2 Click the Summary tab, and click Edit Settings. 3 Select the network adapter from the Hardware list. 4 Record the network settings and MAC address that the network adapter is using. 5 Click Remove to remove the network adapter from the virtual machine. 6 Click Add. 7 Select Ethernet Adapter and click Next. 8 In the Adapter Type group, select Enhanced vmxnet. 9 Select the network setting and MAC address that the old network adapter was  using and click Next. 10 Click Finish. 11 Click OK. 12 If the virtual machine is not set to upgrade VMware Tools at each power‐on, you  must upgrade VMware Tools manually. See the Basic System Administration Guide. TSO is enabled by default on a VMkernel interface. If TSO gets disabled for a particular  VMkernel interface, the only way to enable TSO is to delete that VMkernel interface and  re‐create it with TSO enabled. To check that TSO is enabled on a VMkernel interface 1 Log in directly to your ESX Server 3 hostʹs console. 2 Use the esxcfg-vmknic -l command to display a list of VMkernel interfaces.  Each TSO‐enabled VMkernel interface should appear on the list with TSO MSS set  to 40960. VMware, Inc. 63 ESX Server 3 Configuration Guide If TSO is not enabled for a particular VMkernel interface, the only way to enable TSO is  to delete that VMkernel interface and re‐create that VMkernel interface. See “VMkernel  Networking Configuration” on page 30. Enabling Jumbo Frames Jumbo Frames allow ESX Server 3 to send larger frames out onto the physical network.  The network must support Jumbo Frames end‐to‐end for Jumbo Frames to be effective.  Jumbo Frames up to 9kB (9000 Bytes) are supported. iSCSI with Jumbo Frames is not  supported. Jumbo Frames must be enabled for each vSwitch or VMkernel interface through the  command‐line interface on your ESX Server 3 host. Before enabling Jumbo Frames,  check with your hardware vendor to ensure your physical network adapter supports  Jumbo Frames. To create a Jumbo Frames-enabled vSwitch 1 Log in directly to your ESX Server 3 hostʹs console. 2 Use the esxcfg-vswitch -m  command to set the MTU size  for the vSwitch. This command sets the MTU for all uplinks on that vSwitch. The MTU size should  be set to the largest MTU size among all the virtual network adapters connected to  the vSwitch. 3 Use the esxcfg-vswitch -l command to display a list of vSwitches on the host,  and check that the configuration of the vSwitch is correct. To enable Jumbo Frame support on a virtual machine 1 Log in to the VI Client and select the virtual machine from the inventory panel.  The hardware configuration page for this server appears. 64 2 Click the Summary tab, and click Edit Settings. 3 Select the network adapter from the Hardware list. 4 Record the network settings and MAC address that the network adapter is using. 5 Click Remove to remove the network adapter from the virtual machine. 6 Click Add. 7 Select Ethernet Adapter and click Next. 8 In the Adapter Type group, select Enhanced vmxnet. VMware, Inc. Chapter 3 Advanced Networking 9 Select the network setting and MAC address that the old network adapter was  using and click Next. 10 Click Finish. 11 Select the new network adapter from the Hardware list. 12 Under MAC Address, select Manual, and enter the MAC address that the old  network adapter was using. 13 Click OK. 14 Check that the Enhanced vmxnet adapter is connected to a vSwitch with Jumbo  Frames enabled. 15 Inside the guest operating system, configure the network adapter to allow Jumbo  Frames. See your guest operating system’s documentation for details. 16 Configure all physical switches and any physical or virtual machines to which this  virtual machine connects to support Jumbo Frames. Additionally, the procedure for enabling a VMkernel interface is incomplete. Please use  the following procedure. To create a Jumbo Frames-enabled VMkernel interface 1 Log in directly to your ESX Server 3 host’s console 2 Use the esxcfg-vmknic -a -i -n -m  command to create a VMkernel connection with Jumbo Frame  support. 3 Use the esxcfg-vmknic -l command to display a list of VMkernel interfaces, and  check that the configuration of the Jumbo Frame‐enabled interface is correct. 4 Check that the VMkernel interface is connected to a vSwitch with Jumbo Frames  enabled. 5 Configure all physical switches and any physical or virtual machines to which this  VMkernel interface connects to support Jumbo Frames. NetQueue and Networking Performance NetQueue in ESX Server 3 takes advantage of the capability of some network adapters  to deliver network traffic to the system in multiple receive queues that can be processed  separately. This allows processing to be scaled to multiple CPUs, improving  receive‐size networking performance. VMware, Inc. 65 ESX Server 3 Configuration Guide To enable NetQueue on an ESX Server 3 host 1 Log in to the VI Client and select the server from the inventory panel.  The hardware configuration page for this server appears. 2 Click the Configuration tab, and click Advanced Settings. 3 Select VMkernel. 4 Select VMkernel.Boot.netNetQueueEnable and click OK. 5 Log in directly to your ESX Server 3 hostʹs console to configure your NIC driver to  use NetQueue. 6  If you are using the s2io NIC driver, use the esxcfg-module -s "intr_type=2 rx_ring_num=8" s2io command to set the appropriate  parameters on the s2io module.  If you are using the ixgbe NIC driver, use the esxcfg-module -s “InterruptType=2 MQ=1 VMDQ=16” ixgbe command to set the appropriate  parameters on the ixgbe module.  For third party drivers, contact the third party vendor for appropriate  configurations. Reboot the ESX Server 3 host. To disable NetQueue options on an ESX Server 3 host 1 Log in to the VI Client and select the server from the inventory panel.  The hardware configuration page for this server appears. 2 Click the Configuration tab, and click Advanced Settings. 3 Deselect VMkernel.Boot.netNetQueueEnable and click OK. 4 Log in directly to your ESX Server 3 host’s console. 5 Use the esxcfg-module -s "" [module name] command. For example, if you are using the s2io NIC driver, use esxcfg-module -s "" s2io 6 66 Reboot the ESX Server 3 host. VMware, Inc. Chapter 3 Advanced Networking Setting Up MAC Addresses MAC addresses are generated for virtual network adapters that the service console, the  VMkernel and virtual machines use. In most cases, these MAC addresses are  appropriate. However, you might need to set a MAC address for a virtual network  adapter, as in the following cases:  Virtual network adapters on different physical servers share the same subnet and  are assigned the same MAC address, causing a conflict.   To ensure that a virtual network adapter always has the same MAC address. The following sections describe how MAC addresses are generated and how you can  set the MAC address for a virtual network adapter. MAC Addresses Generation Each virtual network adapter in a virtual machine is assigned its own unique MAC  address. A MAC address is a six‐byte number. Each network adapter manufacturer is  assigned a unique three‐byte prefix called an OUI (Organizationally Unique Identifier)  that it can use to generate unique MAC addresses.  VMware has the following OUIs:  One for generated MAC addresses.  One for manually set MAC addresses.  One that was previously used for legacy virtual machines, but is no longer used  with ESX Server 3. The first three bytes of the MAC address that is generated for each virtual network  adapter are comprised of the OUI. This MAC address‐generation algorithm produces  the other three bytes. The algorithm guarantees unique MAC addresses within a  machine and attempts to provide unique MAC addresses across machines. The network adapters for each virtual machine on the same subnet should have unique  MAC addresses. Otherwise, they can behave unpredictably. The algorithm puts a limit  on the number of running and suspended virtual machines at any one time on any  given server. It also does not handle all cases when virtual machines on distinct  physical machines share a subnet. The VMware Universally Unique Identifier (UUID) generates MAC addresses that are  checked for any conflicts. The generated MAC addresses are created by using three  parts: the VMware OUI, the SMBIOS UUID for the physical ESX Server 3 machine, and  a hash based on the name of the entity that the MAC address is being generated for. VMware, Inc. 67 ESX Server 3 Configuration Guide After the MAC address is generated, it does not change unless the virtual machine is  moved to a different location, for example, to a different path on the same server. The  MAC address in the configuration file of the virtual machine is saved. All MAC  addresses that have been assigned to network adapters of running and suspended  virtual machines on a given physical powered‐off virtual machine is not checked  against those of running or suspended virtual machines. It is possible but unlikely that  when a virtual machine is powered on again, it can acquire a different MAC address.  This acquisition is due to a conflict with a virtual machine that was powered on when  this virtual machine was powered off. Setting MAC Addresses To circumvent the limit of 256 virtual network adapters per physical machine and  possible MAC address conflicts between virtual machines, system administrators can  manually assign MAC addresses. VMware uses this OUI for manually generated  addresses: 00:50:56.  The MAC address range is 00:50:56:00:00:00-00:50:56:3F:FF:FF You can set the addresses by adding the following line to a virtual machine‘s  configuration file: ethernet .address = 00:50:56:XX:YY:ZZ where  refers to the number of the Ethernet adapter, XX is a valid  hexadecimal number between 00 and 3F, and YY and ZZ are valid hexadecimal numbers  between 00 and FF. The value for XX must not be greater than 3F to avoid conflict with  MAC addresses that are generated by the VMware Workstation and VMware GSX  Server products. The maximum value for a manually generated MAC address is ethernet.address = 00:50:56:3F:FF:FF You must also set the option in a virtual machine’s configuration file: ethernet.addressType="static" Because VMware ESX Server 3 virtual machines do not support arbitrary MAC  addresses, the above format must be used. As long as you choose a unique value for  XX:YY:ZZ among your hard‐coded addresses, conflicts between the automatically  assigned MAC addresses and the manually assigned ones should never occur. 68 VMware, Inc. Chapter 3 Advanced Networking Using MAC Addresses You can change a powered‐down virtual machineʹs virtual NICs to use statically  assigned MAC addresses using the VI Client. To set up a MAC address 1 Log in to the VI Client and select the virtual machine from the inventory panel. 2 Click the Summary tab, and click Edit Settings. 3 Select the network adapter from the Hardware list. 4 In the MAC Address group, select Manual. 5 Enter the desired static MAC address, and click OK. Networking Best Practices and Tips This section provides information about:  Networking best practices  Networking tips Networking Best Practices Consider these best practices for configuring your network:  Separate network services from one another to achieve greater security or better  performance. To have a particular set of virtual machines function at the highest performance  levels, put them on a separate physical NIC. This separation allows for a portion of  the total networking workload to be more evenly shared across multiple CPUs.  The isolated virtual machines can then better serve traffic from a Web client, for  instance. VMware, Inc. 69 ESX Server 3 Configuration Guide  You can satisfy the following recommendations either by using VLANs to segment  a single physical network, or by using separate physical networks (the latter is  preferable).  Keeping the service console on its own network is an important part of  securing the ESX Server 3 system. Consider the service console network  connectivity in the same light as any remote access device in a server, because  compromise of the service console gives an attacker full control of all virtual  machines running on the system.  Keeping the VMotion connection on a separate network devoted to VMotion  is important because when migration with VMotion occurs, the contents of the  guest operating system’s memory are transmitted over the network. Mounting NFS Volumes In ESX Server 3, the model of how ESX Server 3 accesses NFS storage of ISO images that  are used as virtual CD‐ROMs for virtual machines is different from the model used in  ESX Server 2.x. ESX Server 3 has support for VMkernel‐based NFS mounts. The new model is to mount  your NFS volume with the ISO images through the VMkernel NFS functionality. All  NFS volumes mounted in this way appear as datastores in the VI Client. The virtual  machine configuration editor allows you to browse the service console file system for  ISO images to be used as virtual CD‐ROM devices. Networking Tips Consider the following networking tips: 70  To physically separate network services and to dedicate a particular set of NICs to  a specific network service, create a vSwitch for each service. If this is not possible,  separate them from each other on a single vSwitch by attaching them to port  groups with different VLAN IDs. In either case, confirm with your network  administrator that the networks or VLANs you choose are isolated in the rest of  your environment, that is, no routers connect them.  You can add and remove NICs from the vSwitch without affecting the virtual  machines or the network service that is running behind that vSwitch. If you  remove all of the running hardware, the virtual machines can still communicate  amongst themselves. Moreover, if you leave one NIC intact, all of the virtual  machines can still connect with the physical network. VMware, Inc. Chapter 3 Advanced Networking  To separate virtual machines into groups, use port groups with different sets of  active adapters in their teaming policy. These can use separate adapters as long as  all adapters are up but still fall back to sharing in the event of a network or  hardware failure.  To protect your most sensitive virtual machines, deploy firewalls in virtual  machines that route between virtual networks with uplinks to physical networks  and pure virtual networks with no uplinks. VMware, Inc. 71 ESX Server 3 Configuration Guide 72 VMware, Inc. 4 Networking Scenarios and Troubleshooting 4 This chapter describes common networking configuration and troubleshooting  scenarios. This chapter discusses the following topics:  “Networking Configuration for Software iSCSI Storage” on page 73  “Configuring Networking on Blade Servers” on page 78  “Troubleshooting” on page 81 Networking Configuration for Software iSCSI Storage The storage you configure for an ESX Server 3 host might include one or more storage  area networks (SANs) that use iSCSI storage, which is a means of accessing SCSI  devices and exchanging data records by using TCP/IP protocol over a network port  rather than through a direct connection to a SCSI device. In iSCSI transactions, blocks  of raw SCSI data are encapsulated in iSCSI records and transmitted to the requesting  device or user. NOTE   Software‐initiated iSCSI is not available over 10GigE network adapters in  ESX Server 3.5. Before you can configure iSCSI storage, you must create a VMkernel port to handle  iSCSI networking and a service console connection to the iSCSI network. VMware, Inc. 73 ESX Server 3 Configuration Guide To create a VMkernel port for software iSCSI 1 Log in to the VI Client and select the server from the inventory panel.  The hardware configuration page for this server appears. 2 Click the Configuration tab, and click Networking.  3 Click Add Networking. 4 Select VMkernel and click Next. The Network Access page appears. On this page you connect the physical network  to the VMkernel, which runs services for iSCSI storage. 5 Select the vSwitch to use or click Create a virtual switch. 6 Select the check boxes for the network adapters that your vSwitch will use. Your choices appear in the Preview pane. Select adapters for each vSwitch so that virtual machines or other services that  connect through the adapter can reach the correct Ethernet segment. If no adapters  appear in the Create a virtual switch group, all of the network adapters in the  system are being used by existing vSwitches.  74 VMware, Inc. Chapter 4 Networking Scenarios and Troubleshooting For information on moving network adapters between vSwitches, see “To add  uplink adapters” on page 45. NOTE   Do not use iSCSI on 100MB network adapters. 7 Click Next. 8 In the Port Group Properties group, select or enter a network label and, optionally,  a VLAN ID. Network Label. A name that identifies the port group that you are creating. When  you configure iSCSI storage, specify this label when you configure a virtual  adapter to be attached to this port group. VLAN ID. Identifies the VLAN that the port group’s network traffic will use.  VLAN IDs are not required. If you are not sure whether or not you need them, ask  your network administrator. VMware, Inc. 75 ESX Server 3 Configuration Guide 9 In the IP Settings group, click Edit to set the VMkernel Default Gateway for  iSCSI. On the Routing tab, the service console and the VMkernel each need their own  gateway information. NOTE   Set a default gateway for the port that you created. You must use a valid  static IP address to configure the VMkernel stack. 10 Click OK. 11 Click Next. 12 Click Back to make any changes. 13 Review your changes on the Ready to Complete page and click Finish. After you create a VMkernel port for iSCSI, you must create a service console  connection on the same vSwitch as the VMkernel port. To configure a service console connection for software iSCSI storage 1 Log in to the VI Client and select the server from the inventory panel.  The hardware configuration page for this server appears. 2 76 Click the Configuration tab and click Networking.  VMware, Inc. Chapter 4 Networking Scenarios and Troubleshooting 3 On the right side of the page, click Properties for the vSwitch associated with the  VMkernel port you have created. 4 On the Ports tab, click Add. 5 As a connection type, select Service Console and click Next. 6 In the Port Group Properties group, enter a network label that identifies the port  group that you are creating. Newer ports and port groups appear at the top of the vSwitch diagram. 7 Enter the IP Address and Subnet Mask, or select the DHCP option Obtain IP  setting automatically for the IP address and subnet mask. Note that this must be  a different IP than the one chosen for the VMkernel. 8 Click Edit to set the Service Console Default Gateway. See “To set the default gateway” on page 37. 9 Click Next. 10 After you determine that the vSwitch is configured correctly, click Finish. After you create a VMkernel port and service console connection, you can enable and  configure software iSCSI storage. For information on configuring iSCSI adapters and  storage, see “iSCSI Storage” on page 110. VMware, Inc. 77 ESX Server 3 Configuration Guide Configuring Networking on Blade Servers Because blade servers might have a limited number of network adapters, you might  need to use VLANs to separate traffic for the service console, VMotion, IP storage, and  various groups of virtual machines.  VMware best practices recommend that the service  console and VMotion have their own networks for security reasons.  If you dedicate  physical adapters to separate vSwitches for this purpose, you might need to relinquish  redundant (teamed) connections or stop isolating the various networking clients, or  both.  VLANs allow you to achieve network segmentation without having to use  multiple physical adapters. For the network blade of a blade server to support an ESX Server 3 port group with  VLAN tagged traffic, you must configure the blade to support 802.1Q and configure the  port as a tagged port. The method for configuring a port as a tagged port differs from server to server. The  following list describes how to configure a tagged port on three of the most commonly  used blade servers: HP Blade Set the port’s VLAN Tagging to enabled. Dell PowerEdge Set the port to Tagged. IBM eServer Blade Center Select Tag in the port’s configuration. To configure a virtual machine port group with VLAN on a blade server 1 Log in to the VI Client and select the server from the inventory panel.  The hardware configuration page for this server appears. 2 Click the Configuration tab, and click Networking.  3 On the right side of the page, click Properties for vSwitch associated with the  service console. 4 On the Ports tab, click Add. 5 Select Virtual Machines for the connection type (default). 6 Click Next. 7 In the Port Group Properties group, enter a network label that identifies the port  group that you are creating. Use network labels to identify migration‐compatible connections common to two  or more hosts. 78 VMware, Inc. Chapter 4 Networking Scenarios and Troubleshooting 8 In the VLAN ID field, enter a number between 1 and 4094.  If you are unsure what to enter, leave this blank or ask your network administrator. 9 Click Next. 10 After you determine that the vSwitch is configured correctly, click Finish. To configure a VMkernel port with VLAN on a blade server 1 Log in to the VI Client and select the server from the inventory panel.  The hardware configuration page for this server appears. 2 Click the Configuration tab, and click Networking.  3 On the right side of the page, click Properties for the vSwitch associated with the  service console. 4 On the Ports tab, click Add. 5 Select VMkernel and click Next. This option lets you connect the physical network to the VMkernel, which runs  services for VMotion and IP storage (NFS or iSCSI). 6 In the Port Group Properties group, select or enter a network label and a  VLAN ID. Network Label. A name that identifies the port group that you are creating. This  is the label that you specify when configuring a virtual adapter to be attached to  this port group, when configuring VMkernel services, such as VMotion and IP  storage. VLAN ID. Identifies the VLAN that the port group’s network traffic will use. VMware, Inc. 79 ESX Server 3 Configuration Guide 7 Select Use this port group for VMotion to enable this port group to advertise itself  to another ESX Server 3 as the network connection where VMotion traffic should  be sent. You can enable this property for only one VMotion and IP storage port group for  each ESX Server 3 host. If this property is not enabled for any port group,  migration with VMotion to this host is not possible. 8 In the IP Settings group, click Edit to set the VMkernel Default Gateway for  VMkernel services, such as VMotion, NAS, and iSCSI. NOTE   Set a default gateway for the port that you created. VirtualCenter 2 behaves  differently than VirtualCenter 1.x. You must use a valid IP address to configure the  VMkernel IP stack, not a dummy address. Under the DNS Configuration tab, the name of the host is entered into the name  field by default. The DNS server addresses and the domain that were specified  during installation are also preselected. On the Routing tab, the service console and the VMkernel each need their own  gateway information. A gateway is needed if connectivity to machines not on the  same IP subnet as the service console or VMkernel. Static IP settings is the default. 9 80 Click OK. VMware, Inc. Chapter 4 Networking Scenarios and Troubleshooting 10 Click Next. 11 Click Back to make any changes. 12 Review your changes on the Ready to Complete page and click Finish. Troubleshooting This section guides you through troubleshooting common networking issues. Troubleshooting Service Console Networking If certain parts of the service console’s networking are misconfigured, you cannot access  your ESX Server 3 host with the VI Client. If this happens, you can reconfigure  networking by connecting directly to the service console and using the following  service console commands:  esxcfg-vswif -l  Provides a list of the service console’s current network interfaces. Check that vswif0 is present and that the current IP address and Netmask are  correct.  esxcfg-vswitch -l  Provides a list of current virtual switch configurations. Check that the uplink adapter configured for the service console is connected to the  appropriate physical network.  exscfg-nics -l  Provides a list of current network adapters. Check that the uplink adapter configured for the service console is up and that the  speed and duplex are both correct.  esxcfg-nics -s   Changes the speed of a network adapter.  esxcfg-nics -d Changes the duplex of a network adapter.  esxcfg-vswif -i vswifX  Changes the service console’s IP address. VMware, Inc. 81 ESX Server 3 Configuration Guide  esxcfg-vswif -n vswifX  Changes the service console’s netmask.  esxcfg-vswitch -U   Removes the uplink for the service console  esxcfg-vswitch -L   Changes the uplink for the service console. If you encounter long waits when using esxcfg-* commands, the DNS might be  misconfigured. The esxcfg-* commands require that DNS be configured so that  localhost name resolution works properly. This requires that the /etc/hosts file  contain an entry for the configured IP address and the 127.0.0.1 localhost address. Troubleshooting Network Adapter Configuration Adding a new network adapter, in certain cases, can cause loss of service console  connectivity and manageability by using the VI Client because of network adapters  getting renamed. If this happens, you must use the service console to rename the affected network  adapters. To rename network adapters by using the service console 1 Log in directly to your ESX Server 3 hostʹs console. 2 Use the esxcfg-nics -l command to see which names were assigned to your  network adapters. 3 Use the esxcfg-vswitch -l command to see which vSwitches, if any, are now  associated with device names no longer shown by esxcfg‐nics. 4 Use the esxcfg-vswitch -U  command to  remove any network adapters that were renamed. 5 Use the esxcfg-vswitch -L  command to re‐add  the network adapters, giving them the correct names. Troubleshooting Physical Switch Configuration In some cases, you might lose vSwitch connectivity when a failover or failback event  occurs. This causes the MAC addresses that virtual machines associated with that  vSwitch use to appear on a different switch port than they previously did. To avoid this problem, put your physical switch in portfast or portfast trunk mode. 82 VMware, Inc. Chapter 4 Networking Scenarios and Troubleshooting Troubleshooting Port Group Configuration Changing the name of a port group when virtual machines are already connected to  that port group causes invalid network configuration for the virtual machines  configured to connect to that port group. The connection from virtual network adapters to port groups is made by name, and the  name is what is stored in the virtual machine configuration. Changing the name of a  port group does not cause a mass reconfiguration of all the virtual machines connected  to that port group. Virtual machines that are already powered on continue to function  until they are powered off because their connections to the network are already  established. Avoid renaming networks after they are in use. After you rename a port group, you  must reconfigure each associated virtual machine by using the service console to reflect  the new port group name. VMware, Inc. 83 ESX Server 3 Configuration Guide 84 VMware, Inc. Storage VMware, Inc. 85 ESX Server 3 Configuration Guide 86 VMware, Inc. 5 Introduction to Storage 5 The Storage section contains overview information about available storage options for  ESX Server 3 and explains how to configure you ESX Server 3 system so that it can use  and manage different types of storage.  For information on specific activities that a storage administrator might need to  perform on storage arrays, see the Fibre Channel SAN Configuration Guide and the  iSCSI SAN Configuration Guide. This chapter discusses the following topics:  “Storage Overview” on page 88  “Types of Physical Storage” on page 88  “Supported Storage Adapters” on page 91  “Datastores” on page 91  “Comparing Types of Storage” on page 97  “Viewing Storage Information in the VMware Infrastructure Client” on page 97  “Configuring and Managing Storage” on page 101 VMware, Inc. 87 ESX Server 3 Configuration Guide Storage Overview An ESX Server 3 virtual machine uses a virtual hard disk to store its operating system,  program files, and other data associated with its activities. A virtual disk is a large  physical file, or a set of files, that can be copied, moved, archived, and backed up as  easily as any other file. To store virtual disk files and manipulate the files, ESX Server 3  requires dedicated storage space. ESX Server 3 uses storage space on a variety of physical storage devices, including your  host’s internal and external storage devices, or networked storage devices. The storage  device is a physical disk or disk array dedicated to the specific tasks of storing and  protecting data. ESX Server 3 can discover storage devices that it has access to and format them as  datastores. The datastore is a special logical container, analogous to a file system on a  logical volume, where ESX Server 3 places virtual disk files and other files that  encapsulate essential components of a virtual machine. Deployed on different devices,  the datastores hide specifics of each storage product and provide a uniform model for  storing virtual machine files.  Using the VI Client, you can set up datastores in advance on any storage device that  your ESX Server 3 discovers.  To learn how to access and configure your storage devices, as well as how to create and  manage datastores, see the following chapters:  Chapter 6, “Configuring Storage,” on page 103  Chapter 7, “Managing Storage,” on page 133 After you create the datastores, you can use them to store virtual machine files. For  information on creating virtual machines, see Basic System Administration. Types of Physical Storage The ESX Server 3 storage management process starts with a storage space that your  storage administrator preallocates on different storage devices.  ESX Server 3 supports the following types of storage devices: 88  Local – Stores virtual machine files on internal or external storage devices or arrays  attached to your ESX Server 3 host through a direct connection.   Networked – Stores virtual machine files on external shared storage devices or  arrays located outside of your ESX Server 3 host. The host communicates with the  networked devices through a high‐speed network. VMware, Inc. Chapter 5 Introduction to Storage Local Storage Local storage devices can be internal hard disks located inside your ESX Server 3 host,  or external storage systems, located outside and connected to the host directly.  Local storage devices do not require a storage network to communicate with your  ESX Server 3. All you need is a cable connected to the storage device and, when  required, a compatible HBA in your ESX Server 3 host.  Generally, you can connect multiple ESX Server 3 hosts to a single local storage system.  The actual number of hosts you connect varies depending on the type of storage device  and topology you use. Many local storage systems support redundant connection paths to ensure fault  tolerance. See “Managing Multiple Paths” on page 137. When multiple ESX Server 3 hosts connect to the local storage unit, they access storage  LUNs in the unshared mode. The unshared mode does not permit several ESX Server 3  hosts to access the same VMFS datastore concurrently. However, a few SAS storage  systems offer shared access to multiple ESX Server 3i hosts. This type of access permits  multiple ESX Server 3i hosts to access the same VMFS datastore on a LUN. See “Sharing  a VMFS Volume Across ESX Server 3 Systems” on page 94. ESX Server 3 supports a variety of internal or external local storage devices, including  SCSI, IDE, SATA, and SAS storage systems. No matter which type of storage you use,  ESX Server 3 hides a physical storage layer from virtual machines.  When you set up your local storage, keep in mind the following:  You cannot use IDE/ATA drives to store virtual machines.   Use local SATA storage, internal and external, in unshared mode only. SATA  storage does not support sharing the same LUNs and, therefore, the same VMFS  datastore across multiple ESX Server 3 hosts.  When you use SATA storage, ensure that your SATA drives are connected through  supported dual SATA/SAS controllers.   Some SAS storage systems can offer shared access to the same LUNs (and,  therefore, the same VMFS datastores) to multiple ESX Server 3 hosts. For information on supported local storage devices, see the I/O Compatibility Guide at  www.vmware.com/support/pubs/vi_pubs.html. VMware, Inc. 89 ESX Server 3 Configuration Guide Networked Storage Networked storage devices are external storage devices, or arrays, that your  ESX Server 3 host uses to store virtual machine files remotely. The ESX Server 3 host  accesses these devices over a high‐speed storage network.  ESX Server 3 supports the following networked storage technologies:  Fibre Channel (FC) – Stores virtual machine files remotely on an FC storage area  network (SAN). FC SAN is a specialized high‐speed network that connects your  ESX Server 3 hosts to high‐performance storage devices. The network uses  Fibre Channel protocol to transport SCSI traffic from virtual machines to the  FC SAN devices.  To connect to the FC SAN, your ESX Server 3 host should be equipped with  Fibre Channel host bus adapters (HBAs) and, unless you use Fibre Channel direct  connect storage, with Fibre Channel switches that help route storage traffic.   Internet SCSI (iSCSI) – Stores virtual machine files on remote iSCSI storage  devices. iSCSI packages SCSI storage traffic into the TCP/IP protocol so that it can  travel through standard TCP/IP networks instead of the specialized FC network.  With iSCSI connection, your ESX Server 3 host serves as the initiator that  communicates with a target, located in remote iSCSI storage systems. ESX Server 3 offers the following types of iSCSI connection:   Hardware Initiated iSCSI – Your ESX Server 3 host connects to storage  through a third‐party iSCSI HBA.  Software Initiated iSCSI – Your ESX Server 3 uses a software‐based iSCSI  initiator in the VMkernel to connect to storage. With this type of iSCSI  connection, your host needs only a standard network adapter for network  connectivity. Network‐Attached Storage (NAS) – Stores virtual machine files on remote file  servers accessed over standard TCP/IP network. The NFS client built into  ESX Server 3 uses the Network File System (NFS) protocol version 3 to  communicate with the NAS/NFS servers. For network connectivity, the  ESX Server 3 host requires a standard network adapter.  See the Storage/SAN Compatibility Guide at www.vmware.com/pdf/vi3_san_guide.pdf. 90 VMware, Inc. Chapter 5 Introduction to Storage Supported Storage Adapters Depending on the type of storage available to you, your ESX Server 3 system might  need adapters that provide connectivity to a specific storage device or network.  ESX Server 3 supports different classes of adapters, including SCSI, iSCSI, RAID,  Fibre Channel, and Ethernet. ESX Server 3 accesses the adapters directly through  device drivers in the VMkernel. For details on the types of adapters that ESX Server 3 supports, see the I/O Compatibility  Guide at www.vmware.com/support/pubs/vi_pubs.html. Datastores You use the VI Client to access different types of storage devices that your ESX Server 3  host discovers and to deploy datastores on them. Datastores are special logical  containers, analogous to file systems, that hide specifics of each storage device and  provide a uniform model for storing virtual machine files.  Datastores can also be used for storing ISO images, virtual machine templates, and  floppy images. See Basic System Administration at www.vmware.com/support/pubs/. Depending on the type of storage you use, ESX Server 3 datastores can have the  following file system formats:  Virtual Machine File System (VMFS) – Special high‐performance file system  optimized for storing ESX Server 3 virtual machines. ESX Server 3 can deploy  VMFS on any SCSI‐based local or networked storage device, including  Fibre Channel and iSCSI SAN equipment.  As an alternative to using the VMFS datastore, your virtual machine can have  direct access to raw devices and use a mapping file (RDM) as a proxy. For more  information on RDMs, see “Raw Device Mapping” on page 145.  Network File System (NFS) – File system on a NAS storage device. ESX Server 3  supports NFS version 3 over TCP/IP. ESX Server 3 can access a designated NFS  volume located on an NFS server. ESX Server 3 mounts the NFS volume and uses  it for its storage needs. If you use service console to access your ESX Server 3 host, you can see the VMFS and  NFS datastores as separate subdirectories in the /vmfs/volumes directory. For  information on using the service console commands and utilities, see “Using  vmkfstools” on page 283. VMware, Inc. 91 ESX Server 3 Configuration Guide VMFS Datastores When your ESX Server 3 host accesses SCSI‐based storage devices such as SCSI, iSCSI,  or FC SAN, the storage space is presented to your ESX Server 3 as a LUN. A LUN is a  logical volume that represents storage space on a single physical disk or on a number  of disks aggregated in a disk array. A single LUN can be created from the entire space  on the storage disk or array, or from a part of the space, called a partition. The LUN that  uses disk space on more than one physical disk or partition still presents itself as a  single logical volume to your ESX Server 3. ESX Server 3 can format LUNs as VMFS datastores. VMFS datastores primarily serve  as repositories for virtual machines. You can store multiple virtual machines on the  same VMFS volume. Each virtual machine, encapsulated in a set of files, occupies a  separate single directory. For the operating system inside the virtual machine, VMFS  preserves the internal file system semantics, which ensures correct application behavior  and data integrity for applications running in virtual machines. In addition, you can use the VMFS datastores to store other files, such as virtual  machine templates and ISO images. VMFS supports the following file and block sizes enabling your virtual machines to run  even the most data intensive applications, including databases, ERP, and CRM in  virtual machines:   Maximum virtual disk size: 2TB with 8MB block size  Maximum file size: 2TB with 8MB block size  Block size: 1MB (default), 2MB, 4MB, and 8MB Creating and Increasing VMFS Datastores You use the VI Client to set up a VMFS datastore in advance on any SCSI‐based storage  device that your ESX Server 3 discovers. ESX Server 3 lets you have up to 256 VMFS  datastores per system with the minimum volume size 1.2GB. NOTE   Always have only one VMFS datastore for each LUN. For information on creating VMFS datastores on the SCSI‐based storage devices, see the  following sections: 92  “Adding Local Storage” on page 104  “Adding Fibre Channel Storage” on page 108  “Adding iSCSI Storage Accessible Through Hardware Initiators” on page 119  “Adding iSCSI Storage Accessible Through Hardware Initiators” on page 119 VMware, Inc. Chapter 5 Introduction to Storage After you create the VMFS datastore, you can edit its properties. See “Editing VMFS  Datastores” on page 134. If your VMFS datastore requires more space, you can dynamically increase the VMFS  volume, up to 64TB, by adding an extent. An extent is a LUN on a physical storage  device that can be dynamically added to any existing VMFS datastore. The datastore  can stretch over multiple extents, yet appear as a single volume. NOTE   You cannot reformat a VMFS volume that a remote ESX Server 3 host is using.  If you attempt to do so, you receive a warning to this effect that specifies the name of  the volume in use and the MAC address of a host NIC that is using it. This warning also  appears in the VMkernel and vmkwarning log files.  Considerations when Creating VMFS Datastores Plan how to set up storage for your ESX Server 3 systems before you format storage  devices with a VMFS datastore.  You might want fewer, larger VMFS volumes for the following reasons:  More flexibility to create virtual machines without asking the storage  administrator for more space.   More flexibility for resizing virtual disks, doing snapshots, and so on.   Fewer VMFS datastores to manage. You might want more, smaller VMFS volumes for the following reasons:  Less wasted storage space.   Different applications might need different RAID characteristics.  More flexibility, as the multipathing policy and disk shares are set per LUN.   Use of Microsoft Cluster Service requires that each cluster disk resource is in its  own LUN.   Better performance. You might decide to configure some of your servers to use fewer, larger VMFS volumes  and other servers to use more, smaller VMFS volumes.  VMware, Inc. 93 ESX Server 3 Configuration Guide Sharing a VMFS Volume Across ESX Server 3 Systems As a cluster file system, VMFS lets multiple ESX Server 3 hosts access the same VMFS  datastore concurrently. You can connect up to 32 hosts to a single VMFS volume.  Figure 5-1. Sharing a VMFS Volume Across ESX Server 3 Hosts ESX Server A ESX Server B ESX Server C VM1 VM2 VM3 VMFS volume disk1 disk2 virtual disk files disk3 To ensure that the same virtual machine is not accessed by multiple servers at the same  time, VMFS provides on‐disk locking. Sharing the same VMFS volume across multiple ESX Server 3 hosts gives you the  following advantages:  You can use VMware Distributed Resource Scheduling and VMware High  Availability.  You can distribute virtual machines across different physical servers. That means  you run a mix of virtual machines on each server so that not all experience high  demand in the same area at the same time.  If a server fails, you can restart virtual machines on another physical server. In case  of a failure, the on‐disk lock for each virtual machine is released. For more information on VMware DRS and VMware HA, see the Resource  Management Guide at www.vmware.com/support/pubs/. 94 VMware, Inc. Chapter 5 Introduction to Storage  You can use VMotion to perform live migration of running virtual machines from  one physical server to another. For more information on VMotion, see Basic System Administration at  www.vmware.com/support/pubs/.  You can use VMware Consolidated Backup, which lets a proxy server, called VCB  proxy, back up a snapshot of a virtual machine while the virtual machine is  powered on and is reading and writing to its storage. For more information on Consolidated Backup, see the Virtual Machine Backup  Guide at www.vmware.com/support/pubs/. NFS Datastore ESX Server 3 can access a designated NFS volume located on a NAS server, mount this  volume, and use it for its storage needs. You can use NFS volumes to store and boot  virtual machines in the same way you use VMFS datastores.  ESX Server 3 supports the following shared storage capabilities on NFS volumes:  Use VMotion.  Use VMware DRS and VMware HA.   Mount ISO images, which are presented as CD‐ROMs to virtual machines.  Create virtual machine snapshots. See Basic System Administration at  www.vmware.com/support/pubs/. How Virtual Machines Access Storage When a virtual machine communicates with its virtual disk stored on a datastore, it  issues SCSI commands. Because datastores can exist on various types of physical  storage, these commands are encapsulated into other forms, depending on the protocol  that the ESX Server 3 system uses to connect to a storage device. ESX Server 3 supports  Fibre Channel (FC), Internet SCSI (iSCSI), and NFS protocols.Regardless of the type of  storage device your ESX Server 3 uses, the virtual disk always appears to the virtual  machine as a mounted SCSI device. The virtual disk hides a physical storage layer from  the virtual machine’s operating system. This allows you to run even operating systems  that are not certified for specific storage equipment, such as SAN, inside the virtual  machine. VMware, Inc. 95 ESX Server 3 Configuration Guide Figure 5‐2 depicts five virtual machines using different types of storage to illustrate the  differences between each type. Figure 5-2. Virtual Machines Accessing Different Types of Storage ESX Server requires TCP/IP connectivity virtual machine virtual machine virtual machine local ethernet virtual machine virtual machine software initiator SCSI fibre channel HBA VMFS SAN iSCSI hardware initiator ethernet NIC LAN ethernet NIC LAN LAN Key physical disk datastore virtual disk VMFS fibre array VMFS iSCSI array NFS NAS appliance NOTE   This diagram is for conceptual purposes only. It is not a recommended  configuration. 96 VMware, Inc. Chapter 5 Introduction to Storage Comparing Types of Storage Table 5‐1 compares networked storage technologies ESX Server 3 supports. Table 5-1. Networked Storage that ESX Server 3 Supports Technology Protocols Transfers Interface Fibre Channel FC/SCSI Block access of  data/LUN FC HBA iSCSI IP/SCSI Block access of  data/LUN  iSCSI HBA (hardware‐initiated  iSCSI)  NIC (software‐initiated iSCSI) NAS IP/NFS File (no direct LUN  access) NIC Table 5‐2 compares the ESX Server 3 features that different types of storage support. Table 5-2. ESX Server 3 Features Supported by Storage RDM VM Cluster VMware HA and DRS VCB VMFS No No No Yes Yes VMFS Yes Yes Yes Yes Yes Yes VMFS Yes No Yes Yes Yes Yes NFS No No Yes Yes Storage Type Boot VM VMotion Datastore SCSI Yes No Fibre  Channel Yes iSCSI NAS over  NFS Viewing Storage Information in the VMware Infrastructure Client The VI Client displays detailed information on available datastores, storage devices  that the datastores use, and configured adapters. For more information, see these  sections:  “Displaying Datastores” on page 98  “Viewing Storage Adapters” on page 99  “Understanding Storage Device Naming in the Display” on page 100 VMware, Inc. 97 ESX Server 3 Configuration Guide Displaying Datastores Datastores are added to the VI Client in the following ways:   Discovered when a host is added to the inventory. When you add a host to the  inventory, the VI Client displays any datastores available to the host.   Created on an available storage device. You can use the Add Storage option to  create and configure a new datastore. See “Configuring Storage” on page 103. You can view a list of available datastores and analyze their properties. To display datastores, on the host Configuration tab, click Storage.  For each datastore, the Storage section shows summary information, including:  Target storage device where the datastore is located. See “Understanding Storage  Device Naming in the Display” on page 100.  Type of file system the datastore uses. See “Datastores” on page 91.  Total capacity, including the used and available space.  To view additional details about the specific datastore, select the datastore from the list.  The Details pane shows the following information: 98  Location of the datastore.  Individual extents that the datastore spans and their capacity (VMFS datastores).  Paths used to access the storage device (VMFS datastores). VMware, Inc. Chapter 5 Introduction to Storage In Figure 5‐3, the symm‐07 datastore is selected from the list of available datastores. The  Details pane provides information about the selected datastore. Figure 5-3. Datastore Information configured datastores datastore details You can refresh and remove any of the existing datastores, and change the properties  of a VMFS datastore. When you edit or reconfigure a VMFS datastore, you can change  its label, add extents, upgrade it, or modify paths for storage devices. See “Managing  Storage” on page 133. Viewing Storage Adapters The VI Client displays any storage adapters available to your system.  To display storage adapters, on the host Configuration tab, click Storage Adapters. You can view the following information about the storage adapters:  Existing storage adapters.  Type of storage adapter, such as Fibre Channel SCSI or iSCSI.  Details for each adapter, such as the storage device it connects to and target ID. To view configuration properties for a specific adapter, select the adapter from the  Storage Adapters list.  VMware, Inc. 99 ESX Server 3 Configuration Guide In Figure 5‐4, the iSCSI hardware vmhba0 adapter is selected. The Details pane  provides information about the number of LUNs the adapter connects to and the paths  it uses. To change the path’s configuration, select this path from the list, right‐click the path,  and click Manage Paths to open the Manage Paths dialog box. See “Managing Multiple  Paths” on page 137. Figure 5-4. Storage Adapter Information Understanding Storage Device Naming in the Display In the VI Client, the name of a storage device is displayed as a sequence of three or four  numbers, separated by colons, such as vmhba1:1:3:1. The name has the following  meaning: ::: The abbreviation vmhba refers to different physical HBAs on the ESX Server 3 system.  It can also refer to the virtual iSCSI initiator that ESX Server 3 implements by using the  VMkernel network stack. The fourth number indicates a partition on a disk that a VMFS  datastore occupies.  The vmhba1:1:3:1 example refers to the first partition on SCSI LUN3, SCSI target 1,  which is accessed through HBA 1. 100 VMware, Inc. Chapter 5 Introduction to Storage Although the third and the fourth numbers never change, the first two numbers can  change. For example, after rebooting the ESX Server 3 system, vmhba1:1:3:1 can  change to vmhba3:2:3:1, however, the name still refers to the same physical device.  The first and the second numbers can change for the following reasons:  The first number, the HBA, changes when an outage on the Fibre Channel or iSCSI  network occurs. In this case, the ESX Server 3 system must use a different HBA to  access the storage device.   The second number, the SCSI target, changes if any modifications occur in the  mappings of the Fibre Channel or iSCSI targets visible to the ESX Server 3 host. Configuring and Managing Storage The Configuring Storage and Managing Storage chapters of this guide discuss most of  the concepts and outline tasks you need to perform when working with storage.  For detailed information on configuring SANs, see the Fibre Channel SAN Configuration  Guide or iSCSI SAN Configuration Guide. For more information about specific storage configuration tasks, see the following:  Local storage configuration: “To create a datastore on a local SCSI disk” on page 105  Fibre Channel SAN storage configuration: “To create a datastore on a Fibre Channel device” on page 108   VMware, Inc. Hardware‐initiated iSCSI storage configuration:  “To view the hardware iSCSI initiator properties” on page 113  “To set up the iSCSI name, alias, and IP address for the hardware initiator” on  page 115  “To set up target discovery addresses using dynamic discovery” on page 116  “To set up CHAP parameters for the hardware initiator” on page 118  “To create a datastore on a hardware iSCSI device” on page 119 Software‐initiated iSCSI storage configuration:  “To view the software iSCSI initiator properties” on page 121  “To enable the software iSCSI initiator” on page 124  “To set up target discovery addresses for the software initiator” on page 124 101 ESX Server 3 Configuration Guide   “To set up CHAP parameters for the software initiator” on page 124  “To create a datastore on an iSCSI device accessed through software initiators”  on page 125 NAS storage configuration: “To mount an NFS volume” on page 129   102 Storage management:  “To upgrade the VMFS‐2 to VMFS‐3” on page 135  “To edit the name of the datastore” on page 136  “To add one or more extents to the datastore” on page 136  “To remove a datastore” on page 134 Path managing:  “To set the multipathing policy” on page 143  “To set the preferred path” on page 144  “To disable a path” on page 144 VMware, Inc. 6 Configuring Storage 6 This chapter contains information about configuring local SCSI storage devices,  Fibre Channel SAN storage, iSCSI storage, and NAS storage. NOTE   For additional information about configuring SANs, see the Fibre Channel  SAN Configuration Guide and iSCSI SAN Configuration Guide. This chapter discusses the following topics:  “Local Storage” on page 104  “Fibre Channel Storage” on page 107  “iSCSI Storage” on page 110  “Performing a Rescan” on page 126  “Network Attached Storage” on page 127  “Creating a Diagnostic Partition” on page 130 VMware, Inc. 103 ESX Server 3 Configuration Guide Local Storage Local storage uses a SCSI‐based device such as your ESX Server 3 host’s hard disk or  any external dedicated storage system connected directly to your ESX Server 3 host.  Figure 6‐1 depicts a virtual machine using local SCSI storage. Figure 6-1. Local Storage ESX Server virtual machine local ethernet SCSI VMFS In this example of local storage topology, the ESX Server 3 host uses a single connection  to plug into a disk. On that disk, you can create a VMFS datastore, which you use to  store virtual machine disk files.  Although this storage configuration is possible, it is not a recommended topology.  Using single connections between storage arrays and ESX Server 3 hosts creates single  points of failure (SPOF) that can cause interruptions when a connection becomes  unreliable or fails. To ensure fault tolerance, some DAS systems support redundant  connection paths. See “Managing Multiple Paths” on page 137. Adding Local Storage As soon as you load storage adapter drivers, ESX Server 3 detects available SCSI  storage devices. Before you create a new datastore on a SCSI device, you might need to  perform a rescan. See “Performing a Rescan” on page 126. When you create a datastore on a SCSI storage device, the Add Storage wizard guides  you through the configuration steps.  104 VMware, Inc. Chapter 6 Configuring Storage To create a datastore on a local SCSI disk 1 Log in to the VI Client and select the server from the inventory panel.  2 Click the Configuration tab and click Storage in the Hardware panel.  3 Click Add Storage.  4 Select the Disk/LUN storage type and click Next. 5 Select the SCSI device to use for your datastore and click Next. The Current Disk Layout page opens. If the disk you are formatting is blank, the  Current Disk Layout page automatically presents the entire disk space to you for  storage configuration. 6 If the disk is not blank, review the current disk layout in the top panel of the  Current Disk Layout page and select a configuration option from the bottom panel:  Use the entire device — Select this option to dedicate the entire disk or LUN  to a single VMFS datastore. VMware recommends that you select this option. WARNING   If you select this option, any file systems or data previously stored on this  device will be destroyed. VMware, Inc. 105 ESX Server 3 Configuration Guide  Use free space — Select this option to deploy a VMFS datastore in the  remaining free space of the disk. 7 Click Next.  8 In the Disk/LUN–Properties page, enter a datastore name and click Next. The Disk/LUN–Formatting page appears.  9 If needed, adjust the file system and capacity values.  By default, the entire free space available on the storage device is offered to you. 10 Click Next. 11 In the Ready to Complete page, review the datastore configuration information  and click Finish.  This process creates a datastore on the local SCSI disk on your ESX Server 3 host.  106 VMware, Inc. Chapter 6 Configuring Storage Fibre Channel Storage ESX Server 3 supports Fibre Channel adapters, which allow an ESX Server 3 system to  be connected to a SAN and see the disk arrays on the SAN.  Figure 6‐2 depicts virtual machines using Fibre Channel storage. Figure 6-2. Fibre Channel Storage ESX Server virtual machine fibre channel HBA SAN VMFS fibre array In this configuration, an ESX Server 3 system connects to SAN fabric, which consists of  Fibre Channel switches and storage arrays, using a Fibre Channel adapter. LUNs from  a storage array become available to your ESX Server 3 system. You can access the LUNs  and create a datastore that you use for your ESX Server 3 storage needs. The datastore  uses the VMFS format. For additional information:  See “Adding Fibre Channel Storage” on page 108.  About configuring SANs, see the Fibre Channel SAN Configuration Guide. VMware, Inc. 107 ESX Server 3 Configuration Guide  About supported SAN storage devices for ESX Server 3, see the Storage/SAN  Compatibility Guide.   About multipathing for Fibre Channel HBAs and how to manage paths, see  “Managing Multiple Paths” on page 137. Adding Fibre Channel Storage Before you create a new datastore on a Fibre Channel device, rescan a Fibre Channel  adapter to discover any newly added LUNs. See “Performing a Rescan” on page 126. When you create a datastore on a Fibre Channel storage device, the Add Storage wizard  guides you through the configuration.  To create a datastore on a Fibre Channel device 1 Log in to the VI Client, and select a server from the inventory panel.  2 Click the Configuration tab and click Storage in the Hardware panel.  3 Click Add Storage.  4 Select the Disk/LUN storage type and click Next. 5 Select the Fibre Channel device to use for your datastore, and click Next. The Current Disk Layout page opens. If the disk you are formatting is blank, the  Current Disk Layout page automatically presents the entire disk space to you for  storage configuration. 6 If the disk is not blank, review the current disk layout in the top panel of the  Current Disk Layout page and select a configuration option from the bottom panel:  Use the entire device — Select this option to dedicate the entire disk or LUN  to a single VMFS datastore. VMware recommends that you select this option. WARNING   If you select this option, any file systems or data previously stored on this  device will be destroyed. 108 VMware, Inc. Chapter 6 Configuring Storage  Use free space — Select this option to deploy a VMFS datastore in the  remaining free space of the disk. 7 Click Next.  8 In the Disk/LUN–Properties page, enter a datastore name and click Next. The Disk/LUN–Formatting page appears. 9 If needed, adjust the file system values and capacity you use for the datastore.  By default, the entire free space available on the storage device is offered to you. 10 Click Next. 11 In the Ready to Complete page, review the datastore configuration information  and click Finish.  This process creates the datastore on a Fibre Channel disk for the ESX Server 3  host.  12 Click Refresh.  For advanced configuration, such as using multipathing, masking, and zoning, see the  Fibre Channel SAN Configuration Guide.  VMware, Inc. 109 ESX Server 3 Configuration Guide iSCSI Storage ESX Server 3 supports iSCSI technology that allows your ESX Server 3 system to use an  IP network while accessing remote storage. With iSCSI, SCSI storage commands that  your virtual machine issues to its virtual disk are converted into TCP/IP protocol  packets and transmitted to a remote device, or target, that stores the virtual disk. From  the point of view of the virtual machine, the device appears as a locally attached SCSI  drive. iSCSI Initiators To access remote targets, your ESX Server 3 host uses iSCSI initiators. Initiators  transport SCSI requests and responses between the ESX Server 3 system and the target  storage device on the IP network. ESX Server 3 supports hardware‐based and software‐based iSCSI initiators:  110  Hardware iSCSI initiator – A third‐party host bus adapter (HBA) with iSCSI over  TCP/IP capability. This specialized iSCSI adapter is responsible for all iSCSI  processing and management.   Software iSCSI initiator – A code built into VMkernel that lets your ESX Server 3  system connect to the iSCSI storage device through standard network adapters.  The software initiator handles the iSCSI processing while communicating with the  network adapter through the network stack. With the software initiator, you can  use the iSCSI technology without purchasing specialized hardware. VMware, Inc. Chapter 6 Configuring Storage Figure 6‐3 depicts two virtual machines that use different types of iSCSI initiators.  Figure 6-3. iSCSI Storage ESX Server virtual machine virtual machine software initiator iSCSI hardware initiator ethernet NIC LAN LAN VMFS iSCSI array In the first example of iSCSI storage configuration, the ESX Server 3 system uses the  hardware iSCSI adapter. This specialized iSCSI adapter sends iSCSI packets to a disk  over a LAN.  In the second example, the ESX Server 3 system is configured with the software iSCSI  initiator. Using the software initiator, the ESX Server 3 system connects to a LAN  through an existing NIC card.  Naming Requirements Because SANs can become large and complex, all iSCSI initiators and targets that use  the network have unique and permanent iSCSI names and are assigned addresses for  access. The iSCSI name provides a correct identification of a particular iSCSI device, an  initiator or a target, regardless of its physical location.  VMware, Inc. 111 ESX Server 3 Configuration Guide When you configure your iSCSI initiators, make sure they have properly formatted  names. The initiators can use one of the following formats:  IQN (iSCSI qualified name) – Can be up to 255 characters long and has the  following format: iqn..: where  represents the year and month your domain name was  registered,  is the official domain name, reversed, and   is any name you want to use, for example, the name of your  server.  An example might be iqn.1998-01.com.mycompany:myserver.   EUI (extended unique identifier) – Represents the eui. prefix followed by the  16‐character name. The name includes 24 bits for company name assigned by the  IEEE and 40 bits for a unique ID such as a serial number. For example, eui.0123456789ABCDEF. Discovery Methods To determine which storage resource on the network is available for access, the  ESX Server 3 system uses these discovery methods:  Dynamic discovery – Also known as Send Targets discovery. Each time the  initiator contacts a specified iSCSI server, it sends the Send Targets request to the  server. The server responds by providing a list of available targets to the initiator.  Static Discovery – The initiator does not need to perform any discovery. The  initiator in advance knows all targets it will be contacting and uses their IP  addresses and domain names to communicate with them. The static discovery method is available only when the iSCSI storage is accessed  through hardware initiators. iSCSI Security Because iSCSI technology uses the IP networks to connect to remote targets, it is  necessary to ensure security of the connection. The IP protocol itself doesn’t protect the  data it transports, and it doesn’t have the capability to verify the legitimacy of initiators  that access targets on the network. You need to take specific measures to guarantee  security across IP networks.  112 VMware, Inc. Chapter 6 Configuring Storage ESX Server 3 supports the Challenge Handshake Authentication Protocol (CHAP) that  your iSCSI initiators can use for authentication purposes. After your initiator  establishes the initial connection with the target, CHAP verifies the identity of the  initiator and checks a CHAP secret that your initiator and the target share. This can be  repeated periodically during the iSCSI session.  When you configure iSCSI initiators for your ESX Server 3 system, check whether the  iSCSI storage supports CHAP and if it does, make sure to enable it for your initiators.  See “Securing iSCSI Storage” on page 204. Configuring Hardware iSCSI Initiators and Storage When your ESX Server 3 communicates with the iSCSI storage through hardware  initiators, it uses a specialized third‐party adapter that can access iSCSI storage over  TCP/IP. This iSCSI adapter handles all iSCSI processing and management for your  ESX Server 3 system. Install and configure the hardware iSCSI adapter before you set up the datastore that  resides on an iSCSI storage device.  Installing and Viewing Hardware iSCSI Initiators For information on which adapters are supported, see the I/O Compatibility Guide on the  VMware Web site at www.vmware.com.  Before you begin configuring the hardware iSCSI initiator, make sure that the iSCSI  HBA is successfully installed and appears on the list of adapters available for  configuration. If the initiator is installed, you can view its properties. To view the hardware iSCSI initiator properties 1 Log in to the VI Client, and select a server from the inventory panel.  2 Click the Configuration tab and click Storage Adapters in the Hardware panel.  The hardware iSCSI initiator appears in the list of storage adapters. VMware, Inc. 113 ESX Server 3 Configuration Guide 3 Select the initiator to configure.  The details for the initiator appear, including the model, IP address, iSCSI name,  discovery methods, iSCSI alias, and any discovered targets. 4 Click Properties.  The iSCSI Initiator Properties dialog box opens. The General tab displays  additional characteristics of the initiator. You can now configure your hardware initiator or change its default characteristics. Configuring Hardware iSCSI Initiators While you configure the hardware iSCSI initiator, set up your initiator’s iSCSI name, IP  address, and discovery addresses. In addition, VMware recommends that you set up  CHAP parameters.  After you configure your hardware iSCSI initiator, perform a rescan, so that all LUNs  that the initiator can access appear on the list of storage devices. See “Performing a  Rescan” on page 126. 114 VMware, Inc. Chapter 6 Configuring Storage Setting Up Naming Parameters When you configure your hardware iSCSI initiators, make sure their names and IP  addresses are formatted properly.  See “Naming Requirements” on page 111. To set up the iSCSI name, alias, and IP address for the hardware initiator 1 In the iSCSI Initiator Properties dialog box, click Configure.  2 To change the default iSCSI name for your initiator, enter the new iSCSI name.  You can use the default name that the vendor supplied. If you change the default  name, make sure the new name you enter is properly formatted. Otherwise, some  storage devices may not recognize the hardware iSCSI initiator. 3 Enter the iSCSI alias.  The alias is a name that you use to identify the hardware iSCSI initiator. 4 Enter all of the required values in the Hardware Initiator Properties group.  5 Click OK to save your changes. 6 Reboot the server for the changes to take effect. Setting up Discovery Addresses for Hardware Initiators Set up target discovery addresses so that the hardware initiator can determine which  storage resource on the network is available for access. You can do this with either  dynamic discovery or static discovery. See “Discovery Methods” on page 112. With dynamic discovery, a particular iSCSI server supplies a list of targets to your  ESX Server 3 host. VMware, Inc. 115 ESX Server 3 Configuration Guide To set up target discovery addresses using dynamic discovery 1 In the iSCSI Initiator Properties dialog box, click the Dynamic Discovery tab. 2 To add a new iSCSI server that your ESX Server 3 host can use for a dynamic  discovery session, click Add.  3 In the Add Send Targets Server dialog box, enter the IP address of the iSCSI server  and click OK. After your ESX Server 3 host establishes the dynamic discovery session with this  server, the server responds by providing a list of targets available to your  ESX Server 3 host. The names and IP addresses of these targets appear on the Static  Discovery tab. 4 To change the IP address of the iSCSI server or remove the server, select the IP  address and click Edit or Remove.  With hardware initiators, in addition to the dynamic discovery method, you can also  use static discovery, where you manually enter the IP addresses and the iSCSI names of  the targets to be contacted. 116 VMware, Inc. Chapter 6 Configuring Storage To set up target discovery address by using static discovery 1 In the iSCSI Initiator Properties dialog box, click the Static Discovery tab. If you previously used the dynamic discovery method, the tab displays any targets  that the iSCSI server supplies to your ESX Server 3 host.  2 To add a target, click Add and enter the target’s IP address and fully qualified  name. 3 To change or delete a specific target, select the target and click Edit or Remove.  NOTE   If you remove a target added by dynamic discovery, the target might be  returned to the list the next time a rescan happens, the HBA is reset, or the system  is rebooted. VMware, Inc. 117 ESX Server 3 Configuration Guide Setting up CHAP Parameters for Hardware Initiators When you configure your hardware iSCSI initiator, verify whether CHAP is enabled on  the iSCSI storage. If it is enabled, enable it for your initiator, making sure that the CHAP  authentication credentials match your iSCSI storage. See “iSCSI Security” on page 112. To set up CHAP parameters for the hardware initiator 1 In the iSCSI Initiator Properties dialog box, click the CHAP Authentication tab.  The tab displays the default CHAP parameters, if any.  118 2 To make any changes to the existing CHAP parameters, click Configure.  3 To keep CHAP enabled, select Use the following CHAP credentials. 4 Either enter a new CHAP name, or select Use initiator name. VMware, Inc. Chapter 6 Configuring Storage 5 If needed, specify the CHAP secret.  All new targets will use the CHAP secret to authenticate the initiator.  6 Click OK to save changes.  NOTE   If you disable CHAP, existing sessions remain until you reboot your  ESX Server 3 host or the storage system forces a logout. After this, you can no  longer connect to targets that require CHAP.  Adding iSCSI Storage Accessible Through Hardware Initiators When you create a datastore on an iSCSI storage device accessible through a hardware  initiator, the Add Storage wizard guides you through the configuration. To create a datastore on a hardware iSCSI device 1 Log in to the VI Client and select a server from the inventory panel.  2 Click the Configuration tab, and click Storage in the Hardware panel. 3 Click Add Storage.  4 Select the Disk/LUN storage type and click Next.  5 Select the iSCSI device you want to use for your datastore, and click Next. The Current Disk Layout page opens. If the disk you are formatting is blank, the  Current Disk Layout page automatically presents the entire disk space to you for  storage configuration. 6 If the disk is not blank, review the current disk layout in the top panel of the  Current Disk Layout page and select a configuration option from the bottom panel:  Use the entire device — Select this option to dedicate the entire disk or LUN  to a single VMFS datastore. VMware recommends that you select this option. WARNING   If you select this option, any file systems or data previously stored on this  device will be destroyed. VMware, Inc. 119 ESX Server 3 Configuration Guide  Use free space — Select this option to deploy a VMFS datastore in the  remaining free space of the disk. 7 Click Next.  8 In the Disk/LUN–Properties page, enter a datastore name and click Next . 9 If needed, adjust the file system values and capacity you use for the datastore. By  default, the entire free space available on the storage device is offered to you. 10 Click Next. 11 Review the datastore information, and click Finish. This creates the datastore on the hardware‐initiated iSCSI device. 12 120 Click Refresh.  VMware, Inc. Chapter 6 Configuring Storage Configuring Software iSCSI Initiators and Storage With the software‐based iSCSI implementation, you can use a standard network  adapter to connect your ESX Server 3 system to a remote iSCSI target on the IP network.  The ESX Server 3 software iSCSI initiator built into VMkernel facilitates this connection  communicating with the network adapter through the network stack.  Before you configure datastores that use software initiators to access the iSCSI storage,  enable network connectivity, then and configure the software iSCSI initiator. Setting Up the iSCSI Storage Accessible Through Software Initiators Perform the following tasks when you prepare and set up datastores that use software  initiators to access the iSCSI storage device. 1 Create a VMkernel port to handle iSCSI networking.  See “VMkernel Networking Configuration” on page 30 and “Networking  Configuration for Software iSCSI Storage” on page 73. 2 Configure a service console connection for software iSCSI.  See “Opening Firewall Ports for Supported Services and Management Agents” on  page 188. 3 Configure the software iSCSI initiator.  See “Configuring Software iSCSI Initiators” on page 123. 4 Rescan for new iSCSI LUNs.  See “Performing a Rescan” on page 126. 5 Set up the datastore.  See “Adding iSCSI Storage Accessible Through Software Initiators” on page 125. Viewing Software iSCSI Initiators The software iSCSI adapter that your ESX Server 3 system uses to access an iSCSI  storage device appears on the list of available adapters. You can use the VI Client to  review its properties. To view the software iSCSI initiator properties 1 Log in to the VI Client, and select a server from the inventory panel.  2 Click the Configuration tab, and click Storage Adapters in the Hardware panel.  The list of available storage adapters appears.  VMware, Inc. 121 ESX Server 3 Configuration Guide 3 Under iSCSI Software Adapter, choose the available software initiator.  If the initiator is enabled, the Details panel displays the initiator’s model, IP  address, iSCSI name, discovery methods, iSCSI alias, and any discovered targets. 122 VMware, Inc. Chapter 6 Configuring Storage 4 Click Properties.  The iSCSI Initiator Properties dialog box opens. The General tab displays  additional characteristics of the software initiator. You can now configure your software initiator or change its default characteristics. Configuring Software iSCSI Initiators When you configure the software iSCSI initiator, you enable your initiator and set up  its target addresses. VMware also recommends that you set up the CHAP parameters.  After you configure your software iSCSI initiator, perform a rescan, so that all LUNs  that the initiator has access to appear on the list of storage devices available to your  ESX Server 3 system. See “Performing a Rescan” on page 126. Enabling Software iSCSI Initiators Enable your software iSCSI initiator so that ESX Server 3 can use it. VMware, Inc. 123 ESX Server 3 Configuration Guide To enable the software iSCSI initiator 1 In the iSCSI Initiator Properties dialog box, click Configure.  2 To enable the initiator, select Enabled. 3 To change the default iSCSI name for your initiator, enter the new name.  Make sure the name you enter is properly formatted. Otherwise, some storage  devices might not recognize the software iSCSI initiator. See “Naming  Requirements” on page 111. 4 Click OK to save your changes. Setting Up Discovery Addresses for Software Initiators Set up target discovery addresses so that the software initiator can determine which  storage resource on the network is available for access. NOTE   With software initiators, only the dynamic discovery method is available. See “Discovery Methods” on page 112. To set up target discovery addresses for the software initiator 1 In the iSCSI Initiator Properties dialog box, click the Dynamic Discovery tab. 2 To add a new iSCSI target that your ESX Server 3 host can use for a dynamic  discovery session, click Add.  3 Enter the Send Targets server IP address and click OK.  4 To change or delete the Send Targets server, select the server and click Edit or  Remove.  Setting Up CHAP Parameters for Software Initiators When you configure your software iSCSI initiator, verify whether CHAP is enabled on  the iSCSI storage. If it is enabled, enable it for the initiator, making sure that the CHAP  authentication credentials match your iSCSI storage. See “iSCSI Security” on page 112. To set up CHAP parameters for the software initiator 124 1 In the iSCSI Initiator Properties dialog box, click the CHAP Authentication tab.  2 To specify CHAP parameters, click Configure. 3 To keep CHAP enabled, select Use the following CHAP credentials. VMware, Inc. Chapter 6 Configuring Storage 4 Enter a CHAP name, or select Use initiator name. 5 If needed, specify the CHAP secret.  All new targets will use the CHAP secret to authenticate the initiator.  6 Click OK to save changes. NOTE   If you disable CHAP, existing sessions remain until you reboot your  ESX Server 3 host or the storage system forces a logout. After this, you can no  longer connect to targets that require CHAP.  Adding iSCSI Storage Accessible Through Software Initiators When you create a datastore on an iSCSI storage device accessible through software  initiators, the Add Storage wizard guides you through the configuration. To create a datastore on an iSCSI device accessed through software initiators 1 Log in to the VI Client, and select a server from the inventory panel.  2 Click the Configuration tab and click Storage in the Hardware panel.  3 Click Add Storage.  4 Select the Disk/LUN storage type and click Next. 5 Select the iSCSI device to use for your datastore, and click Next. The Current Disk Layout page opens. If the disk you are formatting is blank, the  Current Disk Layout page automatically presents the entire disk space to you for  storage configuration. 6 If the disk is not blank, review the current disk layout in the top panel of the  Current Disk Layout page and select a configuration option from the bottom panel:  Use the entire device — Select this option to dedicate the entire disk or LUN  to a single VMFS datastore. VMware recommends that you select this option. WARNING   If you select this option, any file systems or data previously stored on this  device will be destroyed. VMware, Inc. 125 ESX Server 3 Configuration Guide  Use free space — Select this option to deploy a VMFS datastore in the  remaining free space of the disk. 7 Click Next.  8 In the Disk/LUN–Properties page, enter a datastore name and click Next. 9 If needed, adjust the file system values and capacity you use for the datastore. By  default, the entire free space available on the storage device is offered to you. 10 Click Next. 11 Review the datastore information, and click Finish. This process creates the datastore on the software iSCSI storage device. 12 Click Refresh.  Performing a Rescan Perform a rescan if any of the following events occur: 126  When you make changes to storage disks or LUNs available to your ESX Server 3  system.  When you make changes to storage adapters. VMware, Inc. Chapter 6 Configuring Storage  When you create a new datastore or remove an existing one.  When you reconfigure an existing datastore, for example, when you add a new  extent. NOTE   After you mask all paths to a LUN, rescan all adapters with paths to the LUN in  order to update the configuration. To perform a rescan 1 In the VI Client, select a host, and click the Configuration tab.  2 Choose Storage Adapters in the Hardware panel and click Rescan above the  Storage Adapters panel.  NOTE   You can also right‐click an individual adapter and click Rescan to rescan  just that adapter.  3 To discover new disks or LUNs, select Scan for New Storage Devices.  If new LUNs are discovered, they appear in the disk/LUN list.  4 To discover new datastores or update a datastore after its configuration has been  changed, select Scan for New VMFS Volumes.  If new datastores or VMFS volumes are discovered, they appear in the datastore  list.  Network Attached Storage This section contains information about network attached storage (NAS). ESX Server 3 supports using NAS through the NFS protocol.  How Virtual Machines Use NFS The NFS protocol that ESX Server 3 supports enables communication between an NFS  client and NFS server. The client issues requests for information from the server, which  replies with the result.  The NFS client built into ESX Server 3 lets you access the NFS server and use NFS  volumes for storage. ESX Server 3 supports NFS Version 3 over TCP only.  You use the VI Client to configure NFS volumes as datastores. Configured NFS  datastores appear in the VI Client and you can use them to store virtual disk files in the  same way you use VMFS‐based datastores.  VMware, Inc. 127 ESX Server 3 Configuration Guide The virtual disks that you create on NFS‐based datastores use a disk format dictated by  the NFS server, typically a thin‐disk format that requires on‐demand space allocation.   If the virtual machine runs out of space while writing to this disk, the VI Client notifies  you that more space is  needed. You have the following options:  Free up additional space on the volume, so that the virtual machine continues  writing to the disk.   Terminate the virtual machine session. Terminating the session shuts down the  virtual machine. Figure 6‐4 depicts a virtual machine using the NFS volume to store its files.  Figure 6-4. NFS Storage ESX Server virtual machine ethernet NIC LAN NFS NAS appliance In this configuration, ESX Server 3 connects to the NFS server, which stores the virtual  disk files.  WARNING   When ESX Server 3 accesses a virtual machine disk file on an NFS‐based  datastore, a special .lck-XXX lock file is generated in the same directory where the disk  file resides to prevent other ESX Server 3 hosts from accessing this virtual disk file. Do  not remove the .lck-XXX lock file, because without it, the running virtual machine  cannot access its virtual disk file.  128 VMware, Inc. Chapter 6 Configuring Storage NFS Volumes and Virtual Machine Delegate Users If you are planning to create, configure, or administer virtual machines on an  NFS‐based datastore, assign NFS access privileges to a special user, known as the  delegate user. By default, the delegate user for the ESX Server 3 host is root. However, having root  as the delegate user might not work for all NFS volumes. In some cases, to protect NFS  volumes from unauthorized access, NFS administrators export the volumes with the  root squash option turned on. When root squash is on, the NFS server treats access  by the root user as access by any unprivileged user and might refuse the ESX Server 3  host access to virtual machine files stored on the NFS volume.  You can change the delegate user to a different identity through experimental  ESX Server 3 functionality. This identity must match the owner of the directory on the  NFS server, or the ESX Server 3 host cannot perform file level operations.  See “Virtual Machine Delegates for NFS Storage” on page 232. CAUTION   Changing the delegate user for an ESX Server 3 host is experimental and,  currently, VMware provides limited support for this feature. Configuring ESX Server 3 to Access NFS Volumes NFS requires network connectivity to access data stored on remote servers. Before  configuring NFS, you must first configure networking for VMotion and IP storage.  For information on configuring a network, see “VMkernel Networking Configuration”  on page 30. Creating an NFS-Based Datastore When you create a datastore on an NFS volume, the Add Storage wizard guides you  through the configuration steps.  To mount an NFS volume 1 Log in to the VI Client, and select a server from the inventory panel.  2 Click the Configuration tab, and click Storage in the Hardware panel.  3 Click Add Storage. 4 Select Network File System as the storage type and click Next. 5 Enter the server name, the mount point folder name, and the datastore name.  VMware, Inc. 129 ESX Server 3 Configuration Guide 6 Click Next. 7 In the Network File System Summary page, review the configuration options and  click Finish.  Creating a Diagnostic Partition To run successfully, your ESX Server 3 needs to have a diagnostic partition, or a dump  partition, to store core dumps for debugging and technical support. You can create the  diagnostic partition on a local disk, or on a private or shared SAN LUN. A diagnostic partition cannot be located on an iSCSI LUN accessed through a software  initiator. Each ESX Server 3 host must have a diagnostic partition of 100MB. If multiple  ESX Server 3 hosts share a SAN, configure a diagnostic partition with 100MB for each  host. NOTE   If you selected Recommended Partitioning when you installed ESX Server 3,  the installer automatically created a diagnostic partition for your host. The Diagnostic  option doesnʹt appear on the Select Storage Type page. If you selected Advanced  Partitioning and chose not to specify the diagnostic partition during installation,  configure it now. For information on ESX Server 3 partitioning, see the Installation  Guide. To create a diagnostic partition 130 1 Log in to the VI Client, and select a server from the inventory panel.  2 Click the Configuration tab, and click Storage in the Hardware panel.  VMware, Inc. Chapter 6 Configuring Storage 3 Click Add Storage. The Select Storage Type page appears. 4 Select Diagnostic and click Next. If you don’t see Diagnostic as an option, ESX Server 3 host already has a diagnostic  partition. You can query and scan your host’s diagnostic partition by using the  esxcfg-dumppart service console command. See “ESX Server 3 Technical  Support Commands” on page 277. 5 Specify the type of the diagnostic partition:  Private Local – Creates the diagnostic partition on a local disk. This partition  stores fault information only for your ESX Server 3 host.  Private SAN Storage – Creates the diagnostic partition on a non‐shared SAN  LUN. This partition stores fault information only for your ESX Server 3 host.  Shared SAN Storage – Creates the diagnostic partition on a shared SAN LUN.  This partition is accessed by multiple hosts and may store fault information  for more than one host. Click Next.  VMware, Inc. 131 ESX Server 3 Configuration Guide 132 6 Select the device to use for your diagnostic partition and click Next. 7 Review the partition configuration information and click Finish. VMware, Inc. 7 Managing Storage 7 This chapter contains information about managing existing datastores and file systems  that comprise datastores. The chapter discusses the following topics:  “Managing Datastores” on page 133  “Editing VMFS Datastores” on page 134  “Managing Multiple Paths” on page 137  “The vmkfstools Commands” on page 144 Managing Datastores An ESX Server 3 system uses datastores to store all files associated with its virtual  machines. The datastore is a logical storage unit, which can use disk space on one  physical device, one disk partition, or span several physical devices. The datastore can  exist on different types of physical devices, including SCSI, iSCSI, Fibre Channel SAN,  or NFS.  NOTE   As an alternative to using the datastore, your virtual machine can directly access  raw devices by using a mapping file (RDM) as a proxy. See “Raw Device Mapping  Characteristics” on page 150. For more information on datastores, see “Datastores” on page 91. VMware, Inc. 133 ESX Server 3 Configuration Guide Datastores are added to the VI Client in one of the following ways:   Discovered when a host is added to the inventory. When you add a host to the  inventory, the VI Client displays any datastores that the host can recognize.   Created on an available storage device. You can use the Add Storage command to  create and configure a new datastore.  After you create the datastores, you can use them to store virtual machine files. When  needed, you can modify the datastores. For example, you can add extents to your  datastore, rename, or remove it.  You can remove a datastore that you don’t use.  CAUTION   Removing a datastore from the ESX Server 3 system breaks the connection  between the system and the storage device that holds the datastore and stops all  functions of that storage device.  You cannot remove a datastore if it holds virtual disks of a currently running virtual  machine.  To remove a datastore 1 Log in to the VI Client and select a server from the inventory panel.  2 Click the Configuration tab and click Storage.  3 Select the datastore to remove and click Remove.  4 Confirm that you want to remove the datastore. 5 Perform a rescan on all servers that see the datastore. Editing VMFS Datastores Datastores that use the VMFS format are deployed on SCSI‐based storage devices.  After you create a VMFS‐based datastore, you can modify it by renaming or expanding  it. If you have any VMFS‐2 datastores, you can upgrade them to VMFS‐3 format. 134 VMware, Inc. Chapter 7 Managing Storage Upgrading Datastores ESX Server 3 includes VMFS version 3 (VMFS‐3). If your datastore was formatted with  VMFS‐2, you can read files stored on VMFS‐2, but you cannot use them. To use the files,  upgrade VMFS‐2 to VMFS‐3.  When you upgrade VMFS‐2 to VMFS‐3, the ESX Server 3 file‐locking mechanism  ensures that no remote ESX Server 3 or local process is accessing the VMFS volume  being converted. ESX Server 3 preserves all files on the datastore.  As a precaution, before you use the upgrade option, consider the following:  Commit or discard any changes to virtual disks in the VMFS‐2 volume you plan to  upgrade.  Back up the VMFS‐2 volume you want to upgrade.  Be sure that no powered‐on virtual machines are using this VMFS‐2 volume.  Be sure that no other ESX Server host is accessing this VMFS‐2 volume. CAUTION   The VMFS‐2 to VMFS‐3 conversion is a one‐way process. After you convert  the VMFS‐based datastore to VMFS‐3, you cannot revert it back to VMFS‐2. To be able to upgrade the VMFS‐2 file system, its file block size should not exceed 8MB. To upgrade the VMFS-2 to VMFS-3 1 Log in to the VI Client and select a server from the inventory panel.  2 Click the Configuration tab and click Storage.  3 Select the datastore that uses the VMFS‐2 format. 4 Click Upgrade to VMFS‐3. 5 Perform a rescan on all hosts that see the datastore. VMware, Inc. 135 ESX Server 3 Configuration Guide Changing the Names of Datastores You can change the name of an existing VMFS‐based datastore. To edit the name of the datastore 1 Log in to the VI Client and select a server from the inventory panel.  2 Click the Configuration tab and click Storage.  3 Select the datastore whose name you want to edit and click Properties.  4 In the General panel, click Change. 5 Enter the new datastore name and click OK. Adding Extents to Datastores You can expand a datastore that uses the VMFS format by attaching a hard‐disk  partition as an extent. The datastore can span 32 physical storage extents.  You can dynamically add the new extents to the datastore when you need to create new  virtual machines on this datastore, or when the virtual machines running on this  datastore require more space. To add one or more extents to the datastore 1 Log in to the VI Client and select a server from the inventory panel. 2 Click the Configuration tab and click Storage.  3 Select the datastore to expand and click Properties.  4 In the Extents panel, click Add Extent.  5 Select the disk to add as the new extent and click Next.  6 Review the current layout of the disk you are using for the extent to make sure the  disk doesn’t contain any important information. CAUTION   If a disk or partition you add was formatted previously, it will be  reformatted and lose the file systems and any data it contains. 7 Set the capacity for the extent.  By default, the entire free space available on the storage device is offered to you.  8 136 Click Next.  VMware, Inc. Chapter 7 Managing Storage 9 Review the proposed extent layout and the new configuration of your datastore,  and click Finish. 10 Perform a rescan on all servers that see the datastore. Managing Multiple Paths To maintain a constant connection between the ESX Server 3 host and its direct attached  or networked storage, ESX Server 3 supports multipathing. Multipathing is a technique  that lets you use more than one physical element on a path responsible for transferring  data between the ESX Server 3 host and the external storage device. In case of a failure  of any element on the path, an HBA, switch, storage processor (SP), or cable,  ESX Server 3 can use a redundant path. The process of detecting a failed path and  switching to another path is called path failover. This use of failover paths helps ensure  uninterrupted traffic between the ESX Server 3 system and storage devices. To support  multipathing, ESX Server 3 does not require specific failover drivers. NOTE   A virtual machine fails in an unpredictable way if all paths to the storage device  where you stored your virtual machine disks become unavailable. By default, the ESX Server 3 host uses only one path, called the active path, to  communicate with a particular storage device at any given time. When selecting the active path, ESX Server 3 follows these multipathing policies:  Most Recently Used — As its active path, the ESX Server 3 host selects the path it  used most recently. If this path becomes unavailable, the host switches to an  alternative path and continues to use the new path as the active path.  The Most Recently Used policy is required for active/passive storage arrays, in  which one storage processor remains passive waiting for the other to fail.  Fixed — The ESX Server 3 host always uses the designated preferred path to the  storage device as the active path. If the ESX Server 3 host cannot access the storage  through the preferred path, it tries the alternative path, which then becomes the  active path. The host automatically reverts back to the preferred path as soon as it  is available.  VMware recommends the Fixed policy for active/active storage arrays, in which all  storage processors can pass the storage traffic and all paths can be active at all  times, unless a path fails. Most iSCSI storage systems are active/active. NOTE   VMware recommends that you do not manually change Most Recently  Used to Fixed. The system automatically sets this policy for those arrays that  require it.  VMware, Inc. 137 ESX Server 3 Configuration Guide  Round Robin – The ESX Server 3 host uses an automatic path selection rotating  through all available paths. In addition to path failover, round robin supports load  balancing across the paths.  In this release, round robin load balancing is experimental and not supported for  production use. See the Round‐Robin Load Balancing white paper. Multipathing with Local Storage and Fibre Channel SANs In a simplest multipathing local storage topology, you can use one ESX Server 3 host,  which has two HBAs. The ESX Server 3 host connects to a dual‐port local storage  system through two cables. Using this configuration, you can ensure fault tolerance if  one of the connection elements between the ESX Server 3 host and local storage system  fails.  To support path switching with FC SAN, the ESX Server 3 host typically has two or  more HBAs available, from which the storage array can be reached using one or more  switches. Alternatively, the setup could include one HBA and two storage processors  so that the HBA can use a different path to reach the disk array. In Figure 7‐1, multiple paths connect each server with the storage device. For example,  if HBA1 or the link between HBA1 and the switch fails, HBA2 takes over and provides  the connection between the server and the switch. The process of one HBA taking over  for another is called HBA failover. 138 VMware, Inc. Chapter 7 Managing Storage Figure 7-1. Fibre Channel Multipathing ESX Server HBA2 ESX Server HBA1 HBA3 HBA4 switch switch SP1 SP2 storage array Similarly, if SP1 or the link between SP1 and the switch breaks, SP2 takes over and  provides the connection between the switch and the storage device. This process is  called SP failover. VMware ESX Server 3 supports HBA and SP failover with its  multipathing capability.  See the Fibre Channel SAN Configuration Guide. VMware, Inc. 139 ESX Server 3 Configuration Guide Multipathing with iSCSI SAN With iSCSI storage, ESX Server 3 takes advantage of the multipathing support built into  the IP network, which allows the network to perform routing, as Figure 7‐2 shows.  Through Dynamic Discovery, iSCSI initiators obtain a list of target addresses that the  initiators can use as multiple paths to iSCSI LUNs for failover purposes. Figure 7-2. iSCSI Multipathing ESX Server HBA2 ESX Server software initiator HBA1 IP network SP SP iSCSI storage In addition, with the software‐initiated iSCSI, you can use NIC teaming, so that  multipathing is performed through the networking layer in the VMkernel. See  “Networking” on page 17. See the iSCSI SAN Configuration Guide. 140 VMware, Inc. Chapter 7 Managing Storage Viewing the Current Multipathing Status Use the VI Client to view the current multipathing state.  To view the current multipathing state 1 Log in to the VI Client and select a server from the inventory panel.  2 Click the Configuration tab and click Storage in the Hardware panel.  3 From the list of configured datastores, select the datastore whose paths you want  to view or configure.  The Details panel shows the total number of paths being used to access the  datastore and whether any of them are broken or disabled. 4 Click Properties. The Volume Properties dialog box for the selected datastore opens. VMware, Inc. 141 ESX Server 3 Configuration Guide The Extent Device panel includes information on the multipathing policy that the  ESX Server 3 host uses to access the datastore and on the status of each path. The  following path information can appear: 5  Active – The path is working and is the current path being used for  transferring data.   Disabled – The path is disabled and no data can be transferred.   Standby – The path is working but is not currently being used for transferring  data.  Broken – The software cannot connect to the disk through this path. Click Manage Paths to open the Manage Paths dialog box. If you are using the Fixed path policy, you can see which path is the preferred path.  The preferred path is marked with an asterisk (*) in the fourth column. You can use the Manage Paths dialog box to enable or disable your paths, set  multipathing policy, and specify the preferred path.  142 VMware, Inc. Chapter 7 Managing Storage Setting Multipathing Policies for LUNs Use the Manage Paths dialog box to set multipathing policy and specify the preferred  path for the Fixed policy. If you are managing paths for RDMs, see “To manage paths”  on page 158. The Manage Paths dialog box shows the list of different paths to the disk, with the  multipathing policy for the disk and the connection status for each path. It also shows  the preferred path to the disk.  To set the multipathing policy 1 In the Policy panel, click Change.  2 Select one of the following options: 3  Fixed  Most Recently Used  Round Robin (Experimental) Click OK and click Close to save your settings and return to the Configuration  page. NOTE   VMware recommends Most Recently Used for active/passive storage  devices.  If you set the path policy to Fixed, specify the preferred path that the host should  use when it is available.  VMware, Inc. 143 ESX Server 3 Configuration Guide To set the preferred path 1 In the Paths panel, select the path to make the preferred path, and click Change. 2 In the Preference pane, click Preferred.  If Preferred does not appear as an option, make sure that the Path Policy is Fixed.  3 Click OK twice to save your settings and exit the dialog boxes. Disabling Paths To temporarily disable paths for maintenance or any other reasons, use the VI Client.  To disable a path 1 In the Paths panel, select the path to disable and click Change. 2 Select Disabled to disable the path. 3 Click OK twice to save your settings and exit the dialog boxes. The vmkfstools Commands In addition to using VI Client, you can use the vmkfstools program to manage  physical storage devices and to create and manipulate VMFS datastores and volumes  on your ESX Server 3 host.  For a list of supported vmkfstools commands, see “Using vmkfstools” on page 283. 144 VMware, Inc. 8 Raw Device Mapping 8 Raw device mapping (RDM) provides a mechanism for a virtual machine to have direct  access to a LUN on the physical storage subsystem (Fibre Channel or iSCSI only). This  chapter contains information about RDMs.  This chapter discusses the following topics:  “About Raw Device Mapping” on page 145  “Raw Device Mapping Characteristics” on page 150  “Managing Mapped LUNs” on page 155 About Raw Device Mapping RDM is a mapping file in a separate VMFS volume that acts as a proxy for a raw  physical device, a SCSI device used directly by a virtual machine. The RDM contains  metadata used to manage and redirect disk accesses to the physical device. The file  gives you some of the advantages of direct access to a physical device while keeping  some advantages of a virtual disk in the VMFS file system. As a result, it merges VMFS  manageability with raw device access. RDMs can be described in terms such as “Mapping a raw device into a datastore,”  “mapping a system LUN”, or “mapping a disk file to a physical disk volume.” All these  terms refer to RDMs.  VMware, Inc. 145 ESX Server 3 Configuration Guide Figure 8-1. Raw Device Mapping Virtual machine reads, writes opens VMFS volume mapping file address resolution mapped device Although VMware recommends that you use VMFS datastores for most virtual disk  storage, on certain occasions, you might need to use raw LUNs, or logical disks located  in a SAN.  For example, you need to use raw LUNs with RDMs in the following situations:  When SAN snapshot or other layered applications are run in the virtual machine.  The RDM better enables scalable backup offloading systems by using features  inherent to the SAN.  In any MSCS clustering scenario that spans physical hosts — virtual‐to‐virtual  clusters as well as physical‐to‐virtual clusters. In this case, cluster data and quorum  disks should be configured as RDMs rather than as files on a shared VMFS. Think of an RDM as a symbolic link from a VMFS volume to a raw LUN (see  Figure 8‐1). The mapping makes LUNs appear as files in a VMFS volume. The RDM,  not the raw LUN, is referenced in the virtual machine configuration. The RDM contains  a reference to the raw LUN.  Using RDMs, you can: 146  Use VMotion to migrate virtual machines using raw LUNs.  Add raw LUNs to virtual machines using the VI Client.  Use file system features such as distributed file locking, permissions, and naming. VMware, Inc. Chapter 8 Raw Device Mapping Two compatibility modes are available for RDMs:  Virtual compatibility mode allows an RDM to act exactly like a virtual disk file,  including the use of snapshots.   Physical compatibility mode allows direct access of the SCSI device, for those  applications that need lower level control. Benefits of Raw Device Mapping An RDM provides a number of benefits, but it should not be used in every situation. In  general, virtual disk files are preferable to RDMs for manageability. However, when  you need raw devices, you must use the RDM. The following list highlights the benefits  of the RDM:  User‐Friendly Persistent Names – Provides a user‐friendly name for a mapped  device. When you use an RDM, you do not need to refer to the device by its device  name. You refer to it by the name of the mapping file, for example: /vmfs/volumes/myVolume/myVMDirectory/myRawDisk.vmdk  Dynamic Name Resolution – Stores unique identification information for each  mapped device. The VMFS file system associates each RDM with its current SCSI  device, regardless of changes in the physical configuration of the server because of  adapter hardware changes, path changes, device relocation, and so on.  Distributed File Locking – Makes it possible to use VMFS distributed locking for  raw SCSI devices. Distributed locking on an RDM makes it safe to use a shared raw  LUN without losing data when two virtual machines on different servers try to  access the same LUN.  File Permissions – Makes file permissions possible. The permissions of the  mapping file are enforced at file‐open time to protect the mapped volume.   File System Operations – Makes it possible to use file system utilities to work with  a mapped volume, using the mapping file as a proxy. Most operations that are  valid for an ordinary file can be applied to the mapping file and are redirected to  operate on the mapped device.  Snapshots – Makes it possible to use virtual machine snapshots on a mapped  volume.  NOTE   Snapshots are not available when the RDM is used in physical compatibility  mode. VMware, Inc. 147 ESX Server 3 Configuration Guide  VMotion – Lets you migrate a virtual machine with VMotion. The mapping file  acts as a proxy to allow VirtualCenter to migrate the virtual machine by using the  same mechanism that exists for migrating virtual disk files. See Figure 8‐2. Figure 8-2. VMotion of a Virtual Machine Using Raw Device Mapping Server 1 Server 2 VMotion VM1 VM2 VMFS volume mapping file address resolution mapped device  SAN Management Agents – Makes it possible to run some SAN management  agents inside a virtual machine. Similarly, any software that needs to access a  device by using hardware‐specific SCSI commands can be run in a virtual  machine. This kind of software is called SCSI target‐based software. NOTE   When you use SAN management agents, select a physical compatibility  mode for the RDM. 148 VMware, Inc. Chapter 8 Raw Device Mapping  N‐Port ID Virtualization (NPIV) – Makes it possible to use the NPIV technology  that allows a single Fibre Channel HBA port to register with the Fibre Channel  fabric using several worldwide port names (WWPNs). This ability makes the HBA  port appear as multiple virtual ports, each having its own ID and virtual port  name. Virtual machines can then claim each of these virtual ports and use them for  all RDM traffic. NOTE   NPIV can be used only for virtual machines with RDM disks. See the Fibre Channel SAN Configuration Guide. VMware works with vendors of storage management software to ensure that their  software functions correctly in environments that include ESX Server 3. Some  applications of this kind are:  SAN management software  Storage resource management (SRM) software  Snapshot software  Replication software Such software uses a physical compatibility mode for RDMs, so that the software can  access SCSI devices directly.  Various management products are best run centrally (not on the ESX Server 3 machine),  while others run well on the service console or on the virtual machines. VMware does  not certify these applications or provide a compatibility matrix. To find out whether a  SAN management application is supported in an ESX Server 3 environment, contact  the SAN management software provider. Limitations of Raw Device Mapping When you plan to use an RDM, consider the following:  Not Available for Block Devices or Certain RAID Devices – RDM (in the current  implementation) uses a SCSI serial number to identify the mapped device. Because  block devices and some direct‐attach RAID devices do not export serial numbers,  they cannot be used with RDMs.  Available with VMFS‐2 and VMFS‐3 Volumes Only – RDM requires the VMFS‐2  or VMFS‐3 format. In ESX Server 3, the VMFS‐2 file system is read‐only. Upgrade  it to VMFS‐3 to use the files that VMFS‐2 stores. VMware, Inc. 149 ESX Server 3 Configuration Guide  No Snapshots in Physical Compatibility Mode – If you are using an RDM in  physical compatibility mode, you cannot use a snapshot with the disk. Physical  compatibility mode allows the virtual machine to manage its own snapshot or  mirroring operations.  Snapshots are available, however, in virtual mode. See “Virtual Compatibility  Mode Compared to Physical Compatibility Mode” on page 151.  No Partition Mapping – RDM requires the mapped device to be a whole LUN.  Mapping to a partition is not supported. Raw Device Mapping Characteristics An RDM is a special mapping file in a VMFS volume that manages metadata for its  mapped device. The mapping file is presented to the management software as an  ordinary disk file, available for the usual file‐system operations. To the virtual machine,  the storage virtualization layer presents the mapped device as a virtual SCSI device. Key contents of the metadata in the mapping file include the location of the mapped  device (name resolution) and the locking state of the mapped device. Figure 8-3. Mapping File Metadata virtual machine 1 virtual machine 2 virtualization virtualization virtual disk file disk data sectors mapping file location, permissions, locking, etc. disk data sectors mapped device VMFS volume 150 VMware, Inc. Chapter 8 Raw Device Mapping Virtual Compatibility Mode Compared to Physical Compatibility Mode Virtual mode for an RDM specifies full virtualization of the mapped device. It appears  to the guest operating system exactly the same as a virtual disk file in a VMFS volume.  The real hardware characteristics are hidden. Virtual mode allows customers using raw  disks to realize the benefits of VMFS such as advanced file locking for data protection  and snapshots for streamlining development processes. Virtual mode is also more  portable across storage hardware than physical mode, presenting the same behavior as  a virtual disk file. Physical mode for the RDM specifies minimal SCSI virtualization of the mapped  device, allowing the greatest flexibility for SAN management software. In physical  mode, the VMkernel passes all SCSI commands to the device, with one exception: the  REPORT LUNs command is virtualized, so that the VMkernel can isolate the LUN for  the owning virtual machine. Otherwise, all physical characteristics of the underlying  hardware are exposed. Physical mode is useful to run SAN management agents or  other SCSI target based software in the virtual machine. Physical mode also allows  virtual‐to‐physical clustering for cost‐effective high availability. VMware, Inc. 151 ESX Server 3 Configuration Guide Figure 8-4. Virtual And Physical Compatibility Modes virtual machine 1 virtualization virtual mode VMFS mapping file mapped device VMFS volume virtual machine 1 virtualization physical mode VMFS mapping file mapped device VMFS volume Dynamic Name Resolution RDM lets you give a permanent name to a device by referring to the name of the  mapping file in the /vmfs subtree. The example in Figure 8‐5 shows three LUNs. LUN 1 is accessed by its device name,  which is relative to the first visible LUN. LUN 2 is a mapped device, managed by an  RDM on LUN 3. The RDM is accessed by its path name in the /vmfs subtree, which is  fixed. 152 VMware, Inc. Chapter 8 Raw Device Mapping Figure 8-5. Example of Name Resolution server virtual machine 1 scsi0:0.name = vmhba0:0:1:0:mydiskdir /mydiskname.vmdk HBA 1 LUN 3 m hb a1 :0 :1 :0 ) (/vmfs/volumes/myVolume /myVMDirectory/mymapfile) (v (vmhba0:0:1:0) HBA 0 virtual machine 2 scsi0:0.name= mymapfile mapping file LUN 1 VMFS vmhba0:0:3:0 LUN 2 vmhba0:0:1:0 mapped device vmhba0:0:2:0 VMFS uniquely identifies all mapped LUNs, and the identification is stored in its  internal data structures. Any change in the SCSI path, such as a Fibre Channel switch  failure or the addition of a new host bus adapter, can change the vmhba device name,  because the name includes the path designation (initiator, target, LUN). Dynamic name  resolution compensates for these changes by adjusting the data structures to retarget  LUNs to their new device names. VMware, Inc. 153 ESX Server 3 Configuration Guide Raw Device Mapping with Virtual Machine Clusters Use an RDM with virtual machine clusters that need to access the same raw LUN for  failover scenarios. The setup is similar to that of a virtual machine cluster that accesses  the same virtual disk file, but an RDM replaces the virtual disk file. Figure 8-6. Access from Clustered Virtual Machines Server 3 Server 4 VM3 VM4 “shared” access address mapping file mapped device resolutiion VMFS volume See the Resource Management Guide. Comparing Raw Device Mapping to Other Means of SCSI Device Access To help you choose among several available access modes for SCSI devices, Table 8‐1  provides a quick comparison of features available with the different modes.  Table 8-1. Features Available with Virtual Disks and Raw Device Mappings 154 ESX Server 3 Features Virtual Disk File Virtual Mode RDM Physical Mode RDM SCSI Commands Passed Through No No VirtualCenter Support Yes Yes Yes Snapshots Yes Yes No Distributed Locking Yes Yes Yes Yes REPORT LUNs is not  passed through VMware, Inc. Chapter 8 Raw Device Mapping Table 8-1. Features Available with Virtual Disks and Raw Device Mappings (Continued) ESX Server 3 Features Virtual Disk File Virtual Mode RDM Physical Mode RDM Clustering Cluster‐in‐a‐box  only Cluster‐in‐a‐box and  cluster‐across‐boxes N+1 (physical to  virtual clustering  only) SCSI Target-Based Software No No Yes VMware recommends that you use virtual disk files for the cluster‐in‐a‐box type of  clustering. If you plan to reconfigure your cluster‐in‐a‐box clusters as cluster‐across‐boxes  clusters, use virtual mode RDMs for the cluster‐in‐a‐box clusters. See the Resource  Management Guide. Managing Mapped LUNs The tools available to manage mapped LUNs and their RDMs include the VI Client, the  vmkfstools utility, and ordinary file system utilities used in the service console. VMware Infrastructure Client Using the VI Client, you can map a SAN LUN to a datastore and manage paths to your  mapped LUN.  Creating Virtual Machines with RDMs When you give your virtual machine direct access to a raw SAN LUN, you create a  mapping file (RDM) that resides on a VMFS datastore and points to the LUN. Although  the mapping file has the same.vmdk extension as a regular virtual disk file, the RDM  file contains only mapping information. The actual virtual disk data is stored directly  on the LUN.  You can create the RDM as an initial disk for a new virtual machine or add it to an  existing virtual machine. When creating the RDM, you specify the LUN to be mapped  and the datastore on which to put the RDM. VMware, Inc. 155 ESX Server 3 Configuration Guide To create a virtual machine with an RDM 1 Follow all steps required to create a custom virtual machine. See Basic System Administration. 2 In the Select a Disk page, select Raw Device Mapping, and click Next. 3 From the list of SAN disks or LUNs, select a raw LUN for your virtual machine to  access directly. For more information on configuring SAN storage, see the Fibre Channel SAN  Configuration Guide or the iSCSI SAN Configuration Guide. 4 Select a datastore for the RDM mapping file.  You can place the RDM file on the same datastore where your virtual machine  configuration file resides, or select a different datastore. NOTE   To use VMotion for virtual machines with enabled NPIV, make sure that the  RDM files of the virtual machines are located on the same datastore. You cannot  perform Storage VMotion, or VMotion between datastores, when NPIV is enabled.  5 Select a compatibility mode:  Physical compatibility mode allows the guest operating system to access the  hardware directly. Physical compatibility is useful if you are using SAN‐aware  applications on the virtual machine. However, a virtual machine with the  physical compatibility RDM cannot be cloned, made into a template, or  migrated if the migration involves copying the disk.  Virtual compatibility mode allows the RDM to behave as if it were a virtual  disk, so you can use such features as snapshotting, cloning, and so on. 6 Select a virtual device node. 7 If you select Independent mode, choose one of the following:  Persistent – Changes are immediately and permanently written to the disk.  Nonpersistent – Changes to the disk are discarded when you power off or  revert to the snapshot. 8 Click Next. 9 In the Ready to Complete New Virtual Machine page, review your selections. 10 Click Finish to complete your virtual machine. You can also add an RDM to an existing virtual machine. 156 VMware, Inc. Chapter 8 Raw Device Mapping To add an RDM to a virtual machine 1 From the VI Client, click Inventory in the navigation bar, and expand the  inventory as needed. 2 Select the virtual machine from the inventory panel. 3 On the Summary tab, click Edit Settings.  4 Click Add. The Add Hardware Wizard opens. 5 Choose Hard Disk as the type of device to add, and click Next. 6 Select Raw Device Mapping, and click Next. 7 Go to Step 3 of the preceding procedure. VMware, Inc. 157 ESX Server 3 Configuration Guide Managing Paths for a Mapped Raw LUN Use the Manage Paths dialog box to manage paths for your mapping files and mapped  raw LUNs.  To manage paths 1 Log in as administrator or as the owner of the virtual machine to which the  mapped disk belongs. 2 Select the virtual machine from the inventory panel. 3 On the Summary tab click the Edit Settings link.  The Virtual Machine Properties dialog box opens. 4 On the Hardware tab, select Hard Disk, then click Manage Paths. 5 Use the Manage Paths dialog box to enable or disable your paths, set multipathing  policy, and specify the preferred path.  Follow these procedures:  “To set the multipathing policy” on page 143  “To set the preferred path” on page 144  “To disable a path” on page 144 The vmkfstools Utility The vmkfstools command‐line utility can be used in the service console to perform  many of the same operations available through the VI Client. Typical operations  applicable to RDMs are the commands to create a mapping file, to query mapping  information such as the name and identification of the mapped device, and to import  or export a virtual disk.  See “Using vmkfstools” on page 283. 158 VMware, Inc. Chapter 8 Raw Device Mapping File System Operations Most common file system operations done in the service console can be applied to  RDMs.  Table 8-2. Commands Used in Service Console Command Description ls -l Shows the file name and permissions of the mapping file, while showing the  length of the mapped device. du Shows the space used by the mapped device, rather than the mapping file. mv Renames the mapping file, but does not affect the mapped device. cp Copies the contents of a mapped device. You cannot use it to copy a virtual disk  file to a mapped device. Instead, use the vmkfstools command. dd Copies data into or out of a mapped device. However, VMware recommends that  you use vmkfstools import and export commands to copy data. VMware, Inc. 159 ESX Server 3 Configuration Guide 160 VMware, Inc. Security VMware, Inc. 161 ESX Server 3 Configuration Guide 162 VMware, Inc. 9 Security for ESX Server 3 Systems 9 ESX Server is developed with a focus on strong security. This section provides you with  an overview of how VMware ensures security in the ESX Server environment,  addressing system architecture from a security standpoint and giving you a list of  additional security resources. This chapter contains the following sections:  “ESX Server 3 Architecture and Security Features” on page 164  “Security Resources and Information” on page 175 VMware, Inc. 163 ESX Server 3 Configuration Guide ESX Server 3 Architecture and Security Features From a security perspective, VMware ESX Server 3 consists of four major components:  the virtualization layer, the virtual machines, the service console, and the virtual  networking layer. Figure 9‐1 provides an overview of these components. Figure 9-1. ESX Server 3 Architecture virtual machine VMware Virtualization Layer (VMkernel) CPU memory virtual machine virtual machine virtual machine service console ESX Server Virtual Networking Layer hardware network adapter storage Each of these components and this overall architecture are designed to ensure security  of the ESX Server 3 system as a whole.  Security and the Virtualization Layer The virtualization layer, or VMkernel, is a kernel designed by VMware to run virtual  machines. It controls the hardware that ESX Server hosts use and schedules the  allocation of hardware resources among the virtual machines. Because the VMkernel is  fully dedicated to supporting virtual machines and is not used for other purposes, the  interface to the VMkernel is strictly limited to the API required to manage virtual  machines.  164 VMware, Inc. Chapter 9 Security for ESX Server 3 Systems Security and Virtual Machines Virtual machines are the containers in which applications and guest operating systems  run. All VMware virtual machines are isolated from one another. Virtual machines are  designed to contain all users within the guest OS, regardless of the privileges they have.  Even Administrators are isolated from other virtual machines in the same way that they  are isolated from other physical machines. This isolation enables multiple virtual machines to run securely while sharing  hardware and ensures their ability to access hardware and their uninterrupted  performance. For example, if a guest operating system running in a virtual machine  crashes, other virtual machines on the same ESX Server host continue to run. The guest  operating system crash has no effect on:  The ability of users to access the other virtual machines  The ability of the operational virtual machines to access the resources they need  The performance of the other virtual machines Each virtual machine is isolated from other virtual machines running on the same  hardware. While virtual machines share physical resources such as CPU, memory, and  I/O devices, a guest operating system on an individual virtual machine cannot detect  any device other than the virtual devices made available to it, as shown in Figure 9‐2. Figure 9-2. Virtual Machine Isolation Virtual Machine app app app app app Operating System Virtual Machine Resources CPU memory disk network and video cards SCSI controller mouse CD/DVD keyboard Because the VMkernel mediates the physical resources and all physical hardware  access takes place through the VMkernel, virtual machines cannot circumvent this level  of isolation. VMware, Inc. 165 ESX Server 3 Configuration Guide Just as a physical machine can communicate with other machines in a network only  through a network card, a virtual machine can communicate with other virtual  machines running in the same ESX Server host only through a virtual switch. Further,  a virtual machine communicates with the physical network, including virtual machines  on other ESX Server hosts, only through a physical network adapter, as shown in  Figure 9‐3.  Figure 9-3. Virtual Networking Through Virtual Switches ESX Server Virtual Machine virtual network adapter Virtual Machine virtual network adapter VMkernel Virtual Networking Layer Virtual Switch links virtual machines together Hardware Network Adapter links virtual machines to the physical network Physical Network In considering virtual machine isolation in a network context, you can apply these  rules:  If a virtual machine does not share a virtual switch with any other virtual machine,  it is completely isolated from virtual networks within the host.   If no physical network adapter is configured for a virtual machine, the virtual  machine is completely isolated from any physical networks.   If you use the same safeguards (firewalls, antivirus software, and so forth) to  protect a virtual machine from the network as you would for a physical machine,  the virtual machine is as secure as the physical machine would be.  You can further protect virtual machines by setting up resource reservations and limits  on the ESX Server host. For example, through the detailed resource controls available  in ESX Server, you can configure a virtual machine so that it always receives at least ten  percent of the ESX Server host’s CPU resources, but never more than twenty percent.  166 VMware, Inc. Chapter 9 Security for ESX Server 3 Systems Resource reservations and limits protect virtual machines from performance  degradation if another virtual machine tries to consume too many resources on shared  hardware. For example, if one of the virtual machines on an ESX Server host is  incapacitated by a denial‐of‐service (DoS) or distributed denial‐of‐service (DDoS)  attack, a resource limit on that machine prevents the attack from taking up so many  hardware resources that the other virtual machines are also affected. Similarly, a  resource reservation on each of the virtual machines ensures that, in the event of high  resource demands by the virtual machine targeted by the DoS attack, all the other  virtual machines still have enough resources to operate.  By default, ESX Server imposes a form of resource reservation by applying a  distribution algorithm that divides the available host resources equally among the  virtual machines while keeping a certain percentage of resources for use by other  system components such as the service console. This default behavior provides a  degree of natural protection from DoS and DDoS attacks. You set specific resource  reservations and limits on an individual basis to customize the default behavior so that  the distribution isn’t equal across the virtual machine configuration. For a discussion of  how to manage resource allocation for virtual machines, see the Resource Management  Guide.  Security and the Service Console The ESX Server 3 service console is a limited distribution of Linux based on Red Hat  Enterprise Linux 3, Update 8 (RHEL 3 U8). The service console provides an execution  environment to monitor and administer the entire ESX Server 3 host.  If the service console is compromised in certain ways, the virtual machines it interacts  with might also be compromised. To minimize the risk of an attack through the service  console, VMware protects the service console with a firewall. For information about  this firewall, see “Service Console Firewall Configuration” on page 237. In addition to implementing the service console firewall, the following are some of the  other ways VMware mitigates risks to the service console:  ESX Server 3 runs only services essential to managing its functions, and the  distribution is limited to the features required to run ESX Server 3.   By default, ESX Server 3 is installed with a high‐security setting, which means that  all outbound ports are closed and the only inbound ports that are open are those  required for interactions with clients such as the VMware Virtual Infrastructure  Client. VMware recommends that you keep this security setting unless the service  console is connected to a trusted network. VMware, Inc. 167 ESX Server 3 Configuration Guide  By default, all ports not specifically required for management access to the service  console are closed. You must specifically open ports if you need additional  services.  All communications from clients are encrypted through SSL by default. The SSL  connection uses 256‐bit AES block encryption and 1024‐bit RSA key encryption.  The Tomcat Web service, used internally by ESX Server 3 to support access to the  service console by Web clients like Virtual Infrastructure Web Access, has been  modified to run only those functions required for administration and monitoring  by a Web client. As a result, ESX Server 3 is not vulnerable to the Tomcat security  issues reported in broader usage.   VMware monitors all security alerts that could affect service console security and,  if needed, issues a security patch, as it would for any other security vulnerability  that could affect ESX Server 3 hosts. VMware provides security patches for RHEL  3 U6 and later as they become available.  Insecure services such as FTP and Telnet are not installed and the ports for these  services are closed by default. Because more secure services such as SSH and SFTP  are easily available, always avoid using these insecure services in favor of their  safer alternatives. If you must use insecure services and have implemented  sufficient protection for the service console, you must explicitly open ports to  support them.   The number of applications that use a setuid or setgid flag is minimized, and  you can disable any setuid or setgid application that is optional to ESX Server 3  operation. For information on required and optional setuid and setgid  applications, see “setuid and setgid Applications” on page 250. For details on these security measures and other service console security  recommendations, see “Service Console Security” on page 235. Although you can install and run certain types of programs designed for RHEL 3 U6 in  the service console, this usage can have serious security consequences and is not  supported unless VMware explicitly states that it is. If a security vulnerability is  discovered in a supported configuration, VMware proactively notifies all customers  with valid support and subscription contracts and provides all necessary patches.  NOTE   Some security advisories issued by Red Hat do not apply to the ESX Server 3  environment. VMware does not provide notification or patches in these instances. To learn more about VMware’s policies on security patches for supported programs, as  well as its policies on unsupported software, see “Security Resources and Information”  on page 175. 168 VMware, Inc. Chapter 9 Security for ESX Server 3 Systems Security and the Virtual Networking Layer The virtual networking layer consists of the virtual network devices through which  virtual machines and the service console interface with the rest of the network.  ESX Server relies on the virtual networking layer to support communications between  virtual machines and their users. In addition, ESX Server hosts use the virtual  networking layer to communicate with iSCSI SANs, NAS storage, and so forth. The  virtual networking layer includes virtual network adapters and the virtual switches.  The methods you use to secure a virtual machine network depend on which guest  operating system is installed, whether the virtual machines operate in a trusted  environment, and a variety of other factors. Virtual switches provide a substantial  degree of protection when used with other common security practices, such as  installing firewalls. ESX Server also supports IEEE 802.1q VLANs, which you can use  to further protect the virtual machine network, service console, or storage  configuration. VLANs let you segment a physical network so that two machines on the  same physical network cannot send packets to or receive packets from each other  unless they are on the same VLAN.  You can get a sense of how to use virtual switches to implement security tools like  DMZs and configure virtual machines on different networks within the same  ESX Server host by reviewing the following examples. NOTE   For a specific discussion of how virtual switches and VLANs help safeguard the  virtual machine network and a discussion of other security recommendations for  virtual machine networks, see “Securing Virtual Machines with VLANs” on page 195.  VMware, Inc. 169 ESX Server 3 Configuration Guide Example: Creating a Network DMZ On a Single ESX Server Host One example of how to use ESX Server isolation and virtual networking features to  configure a secure environment is the creation of a network demilitarized zone (DMZ)  on a single ESX Server host, as shown in Figure 9‐4. Figure 9-4. DMZ Configured On a Single ESX Server Host ESX Server Virtual Machine 1 Virtual Machine 2 Virtual Machine 3 Virtual Machine 4 firewall server web server application server firewall server virtual switch 1 hardware network adapter 1 External Network virtual switch 2 virtual switch 3 hardware network adapter 2 Internal Network This configuration includes four virtual machines configured to create a virtual DMZ  on Virtual Switch 2. Virtual Machine 1 and Virtual Machine 4 run firewalls and are  connected to virtual adapters through virtual switches. Both of these virtual machines  are multihomed. Of the remaining two virtual machines, Virtual Machine 2 runs a Web  server and Virtual Machine 3 runs as an application server. Both of these virtual  machines are single homed. The Web server and application server occupy the DMZ between the two firewalls. The  conduit between these elements is Virtual Switch 2, which connects the firewalls with  the servers. This switch has no direct connection with any elements outside the DMZ  and is isolated from external traffic by the two firewalls. From an operational viewpoint, external traffic from the Internet enters Virtual  Machine 1 through Hardware Network Adapter 1 (routed by Virtual Switch 1) and is  verified by the firewall installed on this machine. If the firewall authorizes the traffic, it  is routed to the virtual switch in the DMZ, Virtual Switch 2. Because the Web server and  application server are also connected to this switch, they can serve external requests.  170 VMware, Inc. Chapter 9 Security for ESX Server 3 Systems Virtual Switch 2 is also connected to Virtual Machine 4. This virtual machine provides  a firewall between the DMZ and the internal corporate network. This firewall filters  packets from the Web server and application server. If a packet is verified, it is routed  to Hardware Network Adapter 2 through Virtual Switch 3. Hardware Network  Adapter 2 is connected to the internal corporate network. When creating a DMZ on a single ESX Server, you can use fairly lightweight firewalls.  Although a virtual machine in this configuration cannot exert direct control over  another virtual machine or access its memory, all the virtual machines are still  connected through a virtual network, and this network could be used for virus  propagation or targeted for other types of attacks. The virtual machines in the DMZ as  secure as separate physical machines connected to the same network. VMware, Inc. 171 ESX Server 3 Configuration Guide Example: Creating Multiple Networks Within a Single ESX Server Host The ESX Server system is designed so that you can connect some groups of virtual  machines to the internal network, others to the external network, and still others to  both—all on the same ESX Server host. This capability is an outgrowth of basic virtual  machine isolation coupled with a well‐planned use of virtual networking features, as  shown in Figure 9‐5. Figure 9-5. External Networks, Internal Networks, and a DMZ Configured On a Single ESX Server Host ESX Server External Network Internal Network DMZ VM2 internal user VM3 VM6 internal user firewall server VM4 VM7 internal user Web server VM1 VM5 VM8 FTP server internal user firewall server physical network adapters External Network 1 172 Internal Network 2 External Network 2 Internal Network 1 VMware, Inc. Chapter 9 Security for ESX Server 3 Systems Here, the system administrator configured an ESX Server host into three distinct virtual  machine zones, each serving a unique function:  FTP server – Virtual Machine 1 is configured with FTP software and acts as a  holding area for data sent to and from outside resources such as forms and  collateral localized by a vendor.  This virtual machine is associated with an external network only. It has its own  virtual switch and physical network adapter that connect it to External Network 1.  This network is dedicated to servers that the company uses to receive data from  outside sources. For example, the company uses External Network 1 to receive FTP  traffic from vendors and allow vendors access to data stored on externally  available servers though FTP. In addition to servicing Virtual Machine 1, External  Network 1 services FTP servers configured on different ESX Server hosts  throughout the site. Because Virtual Machine 1 doesn’t share a virtual switch or physical network  adapter with any virtual machines in the host, the other resident virtual machines  cannot transmit packets to or receive packets from the Virtual Machine 1 network.  This restriction prevents sniffing attacks, which require sending network traffic to  the victim. More importantly, an attacker cannot use the natural vulnerability of  FTP to access any of the host’s other virtual machines.  Internal virtual machines – Virtual Machines 2 through 5 are reserved for internal  use. These virtual machines process and store company‐private data such as  medical records, legal settlements, and fraud investigations. As a result, the system  administrators must ensure the highest level of protection for these virtual  machines. These virtual machines connect to Internal Network 2 through their own virtual  switch and network adapter. Internal Network 2 is reserved for internal use by  personnel such as claims processors, in‐house lawyers, or adjustors. Virtual Machines 2 through 5 can communicate with one another through the  virtual switch and with internal virtual machines elsewhere on Internal Network  2 through the physical network adapter. They cannot communicate with  externally‐facing machines. As with the FTP server, these virtual machines cannot  send packets to or receive packets from the other virtual machines’ networks.  Similarly, the host’s other virtual machines cannot send packets to or receive  packets from Virtual Machines 2 through 5.  VMware, Inc. 173 ESX Server 3 Configuration Guide  DMZ – Virtual Machines 6 through 8 are configured as a DMZ that the marketing  group uses to publish the company’s external Web site.  This group of virtual machines is associated with External Network 2 and Internal  Network 1. The company uses External Network 2 to support the Web servers that  use the marketing and financial department to host the corporate Web site and  other Web facilities that it hosts to outside users. Internal Network 1 is the conduit  that the marketing department uses to publish web pages to the corporate Web  site, post downloads, and maintain services like user forums. Because these networks are separate from External Network 1 and Internal  Network 2 and the virtual machines have no shared points of contact (switches or  adapters), there is no risk of attack to or from the FTP server or the internal virtual  machine group.  For an example of how to configure a DMZ with virtual machines, see “Example:  Creating a Network DMZ On a Single ESX Server Host” on page 170. By capitalizing on virtual machine isolation, correctly configuring virtual switches, and  maintaining network separation, the system administrator can house all three virtual  machine zones in the same ESX Server host and be confident that there will be no data  or resource breaches.  The company enforces isolation among the virtual machine groups by using multiple  internal and external networks and making sure that the virtual switches and physical  network adapters for each group are completely separate from those of other groups.  Because none of the virtual switches straddle virtual machine zones, the system  administrator succeeds in eliminating the risk of packet leakage from one zone to  another. A virtual switch, by design, cannot leak packets directly to another virtual  switch. The only way for packets to travel from one virtual switch to another is if:  The virtual switches are connected to the same physical LAN.  The virtual switches connect to a common virtual machine, which could then be  used to transmit packets. Neither of these conditions occur in the sample configuration. If system administrators  want to verify that no common virtual switch paths exist, they can check for possible  shared points of contact by reviewing the network switch layout in the VI Client or  VI Web Access. For information on the virtual switch layout, see “Virtual Switches” on  page 21. 174 VMware, Inc. Chapter 9 Security for ESX Server 3 Systems To safeguard the virtual machines’ resources, the system administrator lowers the risk  of DoS and DDoS attacks by configuring a resource reservation and limit for each  virtual machine. The system administrator further protects the ESX Server host and  virtual machines by installing software firewalls at the front and back ends of the DMZ,  ensuring that the ESX Server host is behind a physical firewall, and configuring the  service console and networked storage resources so that each has its own virtual  switch.  Security Resources and Information You can find additional information on security topics through the following resources. Table 9-1. VMware Security Resources on the Web Topic Resource VMware security policy, up‐to‐date  security alerts, security downloads,  and focus discussions of security  topics  www.vmware.com/security/ Corporate security response policy http://www.vmware.com/support/policies/ security_response.html  communities.vmware.com/community/vmtn/general/ security VMware is committed to helping you maintain a secure  environment. To reassure you that any security issues  will be corrected in a timely fashion, the VMware  Security Response Policy states our commitment to  resolve possible vulnerabilities in our products. Third‐party software support policy http://www.vmware.com/support/policies  VMware supports a variety of storage systems,  software agents such as backup agents, system  management agents, and so forth. You can find lists of  agents, tools, and other software that supports  ESX Server 3 by searching  http://www.vmware.com/vmtn/resources for  ESX Server 3 compatibility guides.  The industry offers more products and configurations  than VMware can test. If VMware does not list a  product or configuration in a compatibility guide,  Technical Support will attempt to help you with any  problems, but cannot guarantee that the product or  configuration can be used. Always evaluate any  security risks for unsupported products or  configurations carefully. VMware, Inc. 175 ESX Server 3 Configuration Guide 176 VMware, Inc. 10 Securing an ESX Server 3 Configuration 10 This chapter describes measures you can take to promote a secure environment for  your ESX Server 3 hosts, virtual machines, and iSCSI SANs. The discussion focuses on  network configuration planning from a security perspective and the steps you can take  to protect the components in your configuration from attack. This chapter discusses the following topics:  “Securing the Network with Firewalls” on page 177  “Securing Virtual Machines with VLANs” on page 195  “Securing iSCSI Storage” on page 204 Securing the Network with Firewalls Security administrators use firewalls to safeguard the network or selected components  in the network from intrusion. Firewalls control access to devices within their perimeter  by closing all communication pathways except for those that the administrator  explicitly or implicitly designates as authorized, thus preventing unauthorized use of  the devices. The pathways, or ports, that administrators open in the firewall allow  traffic between devices on different sides of the firewall. VMware, Inc. 177 ESX Server 3 Configuration Guide In a virtual machine environment, you can plan your layout for firewalls between:  Physical machines such as VirtualCenter Management Server hosts and  ESX Server 3 hosts.  One virtual machine and another—for example, between a virtual machine acting  as an external Web server and a virtual machine connected to your company’s  internal network.   A physical machine and a virtual machine such as when you place a firewall  between a physical network adapter card and a virtual machine. How you use firewalls in an ESX Server 3 configuration is based on how you plan to  use the network and how secure any given component needs to be. For example, if you  create a virtual network where each virtual machine is dedicated to running a different  benchmark test suite for the same department, the risk of unwanted access from one  virtual machine to the next is minimal. Hence, you have little need to set up the  configuration so that firewalls are present between the virtual machines. However, to  prevent interruption of a test run from an outside host, you might set up the  configuration so that a firewall is present at the entry point of the virtual network to  protect the entire set of virtual machines. This section shows firewall placement for configurations with and without  VirtualCenter. It also provides information on the firewall ports required for  ESX Server 3 systems.  “Firewalls for Configurations with a VirtualCenter Server” on page 179  “Firewalls for Configurations Without a VirtualCenter Server” on page 182  “TCP and UDP Ports for Management Access” on page 183  “Connecting to VirtualCenter Server Through a Firewall” on page 185  “Connecting to the Virtual Machine Console Through a Firewall” on page 186  “Connecting ESX Server 3 Hosts Through Firewalls” on page 188  “Opening Firewall Ports for Supported Services and Management Agents” on  page 188 For information on the service console firewall, see “Service Console Firewall  Configuration” on page 237. To configure the firewall and port settings during  installation, see the Setup Guide.  178 VMware, Inc. Chapter 10 Securing an ESX Server 3 Configuration Firewalls for Configurations with a VirtualCenter Server If you use a VirtualCenter Server, you can install firewalls at any of the locations shown  in Figure 10‐1. NOTE   Depending on your configuration, you might not need all the firewalls in the  illustration, or you might need firewalls in locations not shown. Figure 10-1. Sample Virtual Infrastructure Network Configuration and Traffic Flow VI Client third-party network management tool VI Web Access Port 902 Port 443 firewall License Server VirtualCenter Server VirtualCenter Ports 443, 902, and 903 Port 27010 Port 27000 firewall Port 902 Ports 443, 902, and 903 Ports 902, 20502250, 8000, and 8042-8045 firewall ESX Server 3i ESX Server 3 storage VMware, Inc. 179 ESX Server 3 Configuration Guide Networks configured with a VirtualCenter Server can receive communications through  several types of clients: the VI Client, VI Web Access, or third‐party network  management clients that use the SDK to interface with the host. During normal  operation, VirtualCenter listens for data from its managed hosts and clients on  designated ports. VirtualCenter also assumes that its managed hosts listen for data  from VirtualCenter on designated ports. If a firewall is present between any of these  elements, you must ensure that the firewall has open ports to support data transfer.  If you access ESX Server 3 hosts through a VirtualCenter Server, you typically protect  the VirtualCenter Server by using a firewall. This firewall provides basic protection for  your network. Whether this firewall lies between the clients and the VirtualCenter  Server or the VirtualCenter Server and the clients are behind the firewall depends on  your deployment. The main point is to ensure that a firewall is present at what you  consider to be an entry point for the system as a whole.  You might also include firewalls at a variety of other access points in the network,  depending on how you plan to use the network and how secure the various devices  need to be. Select the locations for your firewalls based on the security risks that you’ve  identified for your network configuration. The following is a list of firewall locations  common to ESX Server 3 implementations. Many of the firewall locations in the list and  Figure 10‐1 are optional.   Between your Web browser and VI Web Access HTTP and HTTPS proxy server.   Between the VI Client, VI Web Access Client, or a third‐party  network‐management client and the VirtualCenter Server.   If your users access virtual machines through the VI Client, between the VI Client  and the ESX Server 3 host. This connection is in addition to the connection between  the VI Client and the VirtualCenter Server, and it requires a different port.   If your users access virtual machines through a Web browser, between the Web  browser and the ESX Server 3 host. This connection is in addition to the connection  between the VI Web Access Client and VirtualCenter Server, and it requires  different ports.   Between the license server and either the VirtualCenter Server or the ESX Server 3  host. Typically, in configurations that include a VirtualCenter Server, the license  server runs on the same physical machine as does the VirtualCenter Server. In this  case, the license server connects to the ESX Server 3 network through a firewall,  running in parallel with the VirtualCenter Server but using different ports.  In some configurations, you might use an external license server—for example, if  your company wants to control all licenses through a single, dedicated appliance.  Here, you would connect the license server to the VirtualCenter Server through a  firewall between these two servers.  180 VMware, Inc. Chapter 10 Securing an ESX Server 3 Configuration Regardless of how you set up the license‐server connection, the ports you use for  license traffic are the same. For information on licensing, see the Setup Guide.   Between the VirtualCenter Server and the ESX Server 3 hosts.  Between the ESX Server 3 hosts in your network. Although traffic between  ESX Server 3 hosts is usually considered trusted, you can add firewalls between  your ESX Server 3 hosts if you are concerned about security breaches from  machine to machine. If you add firewalls between ESX Server 3 hosts and plan to migrate virtual  machines between the servers, perform cloning, or use VMotion, you must also  open ports in any firewall that divides the source host from the target hosts so that  the source and targets can communicate.   Between the ESX Server 3 hosts and network storage such as NFS or iSCSI storage.  These ports are not specific to VMware, and you configure them according to the  specifications for your network. For information on the ports to open for these communications paths, see “TCP and  UDP Ports for Management Access” on page 183. VMware, Inc. 181 ESX Server 3 Configuration Guide Firewalls for Configurations Without a VirtualCenter Server If you connect clients directly to your ESX Server 3 network instead of using a  VirtualCenter Server, your firewall configuration is somewhat simpler. You might  install firewalls at any of the locations shown in Figure 10‐2. NOTE   Depending on your configuration, you might not need all the firewalls in the  Figure 10‐2, or you might need firewalls in locations not shown. Figure 10-2. Firewall Configuration for ESX Server 3 Networks that a Client Manages Directly VI Web Access VI Client third-party network management tool Port 902 standard http/ Port 903 https ports firewall Port 902 Port 903 Port 443 firewall Ports 902, 20502250, 8000, and 8042-8045 firewall ESX Server 1 ESX Server 2 storage 182 VMware, Inc. Chapter 10 Securing an ESX Server 3 Configuration Networks configured without a VirtualCenter Server receive communications through  the same types of clients as they do if a VirtualCenter Server were present: VI Client,  VI Web Access Clients, or third‐party network management clients. For the most part,  the firewall needs are the same, but there are several key differences:  Just as you would for configurations that include a VirtualCenter Server, be sure a  firewall is present to protect your ESX Server 3 layer or, depending on your  configuration, your clients and ESX Server 3 layer. This firewall provides basic  protection for your network. The firewall ports you use are the same as those you  use if a VirtualCenter Server is in place.  Licensing in this type of configuration is part of the ESX Server 3 package that you  install on each of the ESX Server 3 hosts. Because licensing is resident to the server,  you do not need to install a separate license server. This eliminates the need for a  firewall between the license server and the ESX Server 3 network. NOTE   In some situations, you might want to centralize your licenses. You can  choose to maintain a separate license server or house the license server on one of  the ESX Server 3 hosts in your network. With either of these approaches, you  connect the license server to the ESX Server 3 network through a firewall by using  the ports normally reserved for virtual machine licensing, much as you do if a  VirtualCenter Server is present. Configurations that use a license server other than  the one automatically installed on the ESX Server 3 host require additional setup.  For information on licensing, see the Setup Guide. TCP and UDP Ports for Management Access This section lists predetermined TCP and UDP ports used for management access to  your VirtualCenter Server, ESX Server 3 hosts, and other network components. To  manage network components from outside a firewall, you might need to reconfigure  the firewall to allow access on the appropriate ports.  NOTE   The ports listed in Table 10‐1 are connected through the service console interface  unless otherwise indicated. VMware, Inc. 183 ESX Server 3 Configuration Guide Table 10-1. TCP and UDP Ports Port Purpose Traffic Type 80 HTTP access. Incoming TCP The default non‐secure TCP Web port typically used in  conjunction with port 443 as a front end for access to  ESX Server 3 networks from the Web, Port 80 redirects traffic to  an HTTPS landing page (port 443) from which you launch the  virtual machine console. Use port 80 for connection to VI Web Access from the Web. WS‐Management uses port 80. 427 443 The CIM client uses the Service Location Protocol, version 2  (SLPv2) to find CIM servers. Incoming and  outgoing UDP HTTPS access. Incoming TCP The default SSL Web port. Use Port 443 for the following:  Connection to VI Web Access from the Web.  VI Web Access and third‐party network management  client connections to the VirtualCenter Server.  Direct VI Web Access and third‐party network  management clients access to ESX Server 3 hosts.  VI Client access to the VirtualCenter Server.  Direct VI Client access to ESX Server 3 hosts.   WS‐Management.  VMware Update Manager.  VMware Converter. 902 Authentication traffic for the ESX Server 3. Use Port 902 for  ESX Server 3 host access to other ESX Server 3 hosts for  migration and provisioning. Incoming TCP,  outgoing UDP 903 Remote console traffic that user access to virtual machines  generates on a specific ESX Server 3 host. Incoming TCP Use Port 903 for the following: 2049  VI Client access to virtual machine consoles.  VI Web Access Client access to virtual machine consoles. Transactions from your NFS storage devices. This port is used on the VMkernel interface rather than the  service console interface. Incoming and  outgoing TCP 2050–2250 Traffic between ESX Server 3 hosts for VMware High  Availability (HA) and EMC Autostart Manager.  Outgoing TCP,  incoming and  outgoing UDP 3260 Transactions from your iSCSI storage devices. Outgoing TCP This port is used on the VMkernel interface and the service  console interface. 184 VMware, Inc. Chapter 10 Securing an ESX Server 3 Configuration Table 10-1. TCP and UDP Ports (Continued) Port Purpose Traffic Type 5900‐5906 RFB protocol which is used by management tools such as VNC. Incoming and  outgoing TCP 5988 CIM XML transactions over HTTPS. (SEE UPDATE) Incoming and  outgoing TCP 5989 CIM XML transactions over HTTP. (SEE UPDATE) Incoming and  outgoing TCP 8000 Incoming requests from VMotion. Incoming and  outgoing TCP This port is used on the VMkernel interface rather than the  service console interface. 8042–8045 Traffic between ESX Server 3 hosts for HA and EMC Autostart  Manager. Outgoing TCP,  incoming and  outgoing UDP 27000 License transactions from ESX Server 3 to the license server  (lmgrd.exe) Incoming and  outgoing TCP 27010 License transactions from ESX Server 3 to the license server  (vmwarelm.exe). Incoming and  outgoing TCP In addition to the TCP and UDP ports just discussed, you can configure other ports  depending on your needs:  You can use VI Client to open ports for installed management agents and  supported services such as SSH, NFS, and so forth. For information on configuring  additional ports for these services, see “Opening Firewall Ports for Supported  Services and Management Agents” on page 188.  You can open ports in the service console firewall for other services and agents  required for your network by running command‐line scripts. See “Service Console  Firewall Configuration” on page 237. Connecting to VirtualCenter Server Through a Firewall As shown in Table 10‐1, the port that VirtualCenter Server uses to listen for data  transfer from its clients is 443. If you have a firewall between your VirtualCenter Server  and its clients, you must configure a connection through which the VirtualCenter  Server can receive data from the clients.  To enable the VirtualCenter Server to receive data from a Client, open port 443. Contact  the firewall system administrator for additional information on configuring ports in a  firewall. VMware, Inc. 185 ESX Server 3 Configuration Guide If you are using the VI Client and do not want to use port 443 as the port for the  VI Client‐to‐VirtualCenter Server communication, you can switch to another port by  changing the VirtualCenter settings in the VI Client. To learn how to change these  settings, see the Basic System Administration Guide. Connecting to the Virtual Machine Console Through a Firewall Whether you connect your client to ESX Server 3 hosts through a VirtualCenter Server  or use a direct connection to the ESX Server 3 host, certain ports are required for user  and administrator communication with virtual machine consoles. These ports support  different client functions, interface with different layers on ESX Server 3, and use  different authentication protocols. They are:  Port 902 – The VirtualCenter Server uses this port to send data to the VirtualCenter  managed hosts. Port 902 is the port that the VirtualCenter Server assumes is  available when sending data to the ESX Server 3 host. VMware doesn’t support  configuring a different port for this connection. Port 902 connects the VirtualCenter Server to the ESX Server 3 host through the  VMware Authorization Daemon (vmware-authd). This daemon then multiplexes  port 902 data to the appropriate recipient for processing.  Port 443 – The VI Client, VI Web Access Client, and SDK use this port to send data  to the VirtualCenter managed hosts. Also, the VI Client, VI Web Access Client, and  SDK, when connected directly to an ESX Server 3 host, use this port to support any  management functions related to the server and its virtual machines. Port 443 is the  port that clients assume is available when sending data to the ESX Server 3 host.  VMware does not support configuring a different port for these connections.  Port 443 connects clients to the ESX Server 3 host through the Tomcat Web service  or the SDK. The vmware-hostd multiplexes port 443 data to the appropriate  recipient for processing.  Port 903 – The VI Client and VI Web Access use this port to provide a connection  for guest operating system mouse‐keyboard‐screen (MKS) activities on virtual  machines. It is through this port that users interact with the guest operating  systems and applications of the virtual machine. Port 903 is the port that the  VI Client and VI Web Access assume is available when interacting with virtual  machines. VMware does not support configuring a different port for this function.  Port 903 connects the VI Client to a specified virtual machine configured on the  ESX Server 3 host.  186 VMware, Inc. Chapter 10 Securing an ESX Server 3 Configuration Figure 10‐3 shows the relationships between VI Client functions, ports, and  ESX Server 3 processes. The VI Web Access Client uses the same basic mapping for its  interactions with the ESX Server 3 host. Figure 10-3. Port Usage for VI Client Communications with ESX Server 3 VI Client virtual machine management functions virtual machine console firewall Port 443 Port 903 ESX Server service console VMkernel vmware-hostd virtual machine vmware-authd vmkauthd If you have a firewall between your VirtualCenter Server and VirtualCenter managed  host, open Ports 443 and 903 in the firewall to allow data transfer to:   ESX Server 3 hosts from the VirtualCenter Server.  ESX Server 3 hosts directly from the VI Client and VI Web Access.  For additional information on configuring the ports, see the firewall system  administrator. VMware, Inc. 187 ESX Server 3 Configuration Guide Connecting ESX Server 3 Hosts Through Firewalls If you have a firewall between two ESX Server 3 hosts and you want to allow  transactions between the hosts or use VirtualCenter to perform any source or target  activities, such as VMware High Availability (HA) traffic, migration, cloning, or  VMotion, you must configure a connection through which the managed hosts can  receive data. To do so, you open ports in the following ranges:  443 (server‐to‐server migration and provisioning traffic)  2050–2250 (for HA traffic)  8000 (for VMotion)  8042–8045 (for HA traffic) For additional information on configuring the ports, see the firewall system  administrator. For more detailed information on the directionality and protocol for  these ports, see “TCP and UDP Ports for Management Access” on page 183. Opening Firewall Ports for Supported Services and Management Agents Use VI Client to configure the service console firewall to accept commonly supported  services and installed management agents. When you configure the ESX Server 3 host  security profile in VirtualCenter, you add or remove these services or agents,  automatically opening or closing predetermined ports in the firewall to allow  communication with the service or agent. The following is a list of the services and  agents you can add or remove: 188  NIS client  NFS client (insecure service)  SMB client (insecure service)  FTP client (insecure service)  SSH client   Telnet client (insecure service)  NTP client  iSCSI software client  SSH server   Telnet server (insecure service) VMware, Inc. Chapter 10 Securing an ESX Server 3 Configuration  FTP server (insecure service)  NFS server (insecure service)  CIM HTTP server (insecure service)  CIM HTTPS server  SNMP server  Syslog client  Other supported management agents you install NOTE   This list can change, so you might find that the VI Client provides services and  agents not mentioned in the list. Also, not all services on the list are installed by default.  You might need to perform additional tasks to configure and enable these services. If you are installing a device, service, or agent not on this list, open ports in the service  console firewall from a command line. See “Service Console Firewall Configuration” on  page 237. VMware, Inc. 189 ESX Server 3 Configuration Guide To allow access to ESX Server 3 for a service or management agent 1 Log in to the VI Client and select the server from the inventory panel. 2 Click the Configuration tab and click Security Profile.  The VI Client displays a list of currently active incoming and outgoing connections  with the corresponding firewall ports. 190 VMware, Inc. Chapter 10 Securing an ESX Server 3 Configuration 3 Click Properties to open the Firewall Properties dialog box.  The Firewall Properties dialog box lists all the services and management agents  you can configure for the host. 4 Select the services and agents to enable.  The Incoming Ports and Outgoing Ports columns indicate the port or ports that  the VI Client opens for the service, the Protocol column indicates the protocol the  service uses, and the Daemon column indicates the status of daemons associated  with the service. 5 Click OK. Automating Service Behavior Based on Firewall Settings ESX Server 3 can automate whether or not services start based on the status of firewall  ports. Such automation helps ensure that services start if the environment is configured  to enable their function. For example, starting a network service only if some ports are  open can help avoid the situation where services are started, but are unable to complete  the communications required to complete their intended purpose. For example, having accurate information about the current time is a requirement for  some protocols, such as Kerberos. The NTP service is a way of getting accurate time  information, but this service only works when required ports are opened in the firewall.  Therefore, the service cannot achieve its goal if all ports are closed. The NTP services  VMware, Inc. 191 ESX Server 3 Configuration Guide provide an option to configure the conditions when the service starts or stops. This  configuration includes options that account for whether firewall ports are opened, and  then start or stop the NTP service based on those conditions. Several possible  configuration options exist, all of which are also applicable to the SSH server. NOTE   The settings described in this section only apply to service settings configured  through the VI Client or applications created with the VMware Infrastructure SDK.  Configurations made through other means, such as the esxcfg‐firewall utility or  configuration files in /etc/init.d/ are not affected by these settings. 192  Start automatically if any ports are open, and stop when all ports are closed – The  default setting for these services that VMware recommends. If any port is open, the  client attempts to contact the network resources pertinent to the service in  question. If some ports are open, but the port for a particular service is closed, the  attempt fails, but there is little drawback to such a case, and if and when the  applicable outgoing port is opened, the service begins completing its tasks.  Start and stop with host – The service starts shortly after the host starts and closes  shortly before the host shuts down. Much like Start automatically if any ports are  open, and stop when all ports are closed, this option means that the service  regularly attempts to complete its tasks, such as contacting the specified NTP  server, in the case of NTP. If the port was closed, but is subsequently opened, the  client begins completing its tasks shortly thereafter.  Start and stop manually – The host preserves the user‐determined service settings,  regardless of whether ports are open or not. When a user starts the NTP service,  that service is kept running as long as the host is powered on. If the service is  started and the host is powered off, the service is stopped as part of the shut‐down  process, but as soon as the host is powered on, the service is started again,  preserving the user‐determined state. VMware, Inc. Chapter 10 Securing an ESX Server 3 Configuration To configure how service startup relates to firewall configuration 1 Log in to the VI Client and select the server from the inventory panel. 2 Click the Configuration tab and click Security Profile.  The VI Client displays a list of currently active incoming and outgoing connections  with the corresponding firewall ports. VMware, Inc. 193 ESX Server 3 Configuration Guide 3 Click Properties. The Firewall Properties dialog box lists all the services and management agents  you can configure for the host. 4 Select the service to configure, and click Options. The Startup Policy determines when the service starts. This dialog box also  provides information about the current state of the service and provides an  interface for manually starting, stopping, or restarting the service. 194 5 Select an option from the Startup Policy choices. 6 Click OK. VMware, Inc. Chapter 10 Securing an ESX Server 3 Configuration Securing Virtual Machines with VLANs The network can be one of the most vulnerable parts of any system. Just as the physical  network requires protection, so does your virtual machine network. If your virtual  machine network is connected to a physical network, it can be subject to breaches to the  same degree that a network made up of physical machines would be. Even if the virtual  machine network is isolated from any physical network, virtual machines in the  network can be subject to attacks from other virtual machines in the network. The  requirements for securing virtual machines are often the same as those for physical  machines.  Virtual machines are isolated from each other. One virtual machine cannot read or  write another virtual machine’s memory, access its data, use its applications, and so  forth. However, within the network, any virtual machine or group of virtual machines  can still be the target of unauthorized access from other virtual machines and might  require further protection by external means. You can add this level of security by:   Adding firewall protection to your virtual network by installing and configuring  software firewalls on some or all of its virtual machines. For efficiency, you can set up private virtual machine Ethernet networks, or virtual  networks. With virtual networks, you install a software firewall on a virtual  machine at the head of the virtual network. This serves as a protective buffer  between the physical network adapter and the remaining virtual machines in the  virtual network.  Installing a software firewall on virtual machines at the head of virtual networks  is a good security practice. However, because software firewalls can slow  performance, balance your security needs against performance before you decide  to install software firewalls on virtual machines elsewhere in the virtual network.  See “Networking Concepts Overview” on page 20.  Keeping different virtual machine zones within a host on different network  segments. If you isolate virtual machine zones on their own network segments,  you minimize the risks of data leakage from one virtual machine zone to the next.  Segmentation prevents various threats, including Address Resolution Protocol  (ARP) spoofing, in which an attacker manipulates the ARP table to remap MAC  and IP addresses, thereby gaining access to network traffic to and from a host.  Attackers use ARP spoofing to generate denials of service, hijack the target system,  and otherwise disrupt the virtual network. VMware, Inc. 195 ESX Server 3 Configuration Guide Planning segmentation carefully lowers the chances of packet transmissions  between virtual machine zones, thus preventing sniffing attacks, which require  sending network traffic to the victim. Also, an attacker cannot use an insecure  service in one virtual machine zone to access other virtual machine zones in the  host. You can implement segmentation by using either of two approaches, each of  which has different benefits.  Use separate physical network adapters for virtual machine zones to ensure  that the zones are isolated. Maintaining separate physical network adapters  for virtual machine zones is probably the most secure method and is less  prone to misconfiguration after the initial segment creation.  Set up virtual local area networks (VLANs) to help safeguard your network.  Because VLANs provide almost all of the security benefits inherent in  implementing physically separate networks without the hardware overhead,  they offer a viable solution that can save you the cost of deploying and  maintaining additional devices, cabling, and so forth. VLANs are an IEEE standard networking scheme with specific tagging methods that  allow routing of packets to only those ports that are part of the VLAN. When properly  configured, VLANs provide a dependable means for you to protect a set of virtual  machines from accidental or malicious intrusions.  VLANs let you segment a physical network so that two machines in the network are  unable to transmit packets back and forth unless they are part of the same VLAN. For  example, accounting records and transactions are among a company’s most sensitive  internal information. In a company whose sales, shipping, and accounting employees  all use virtual machines in the same physical network, you might protect the virtual  machines for the accounting department by setting up VLANs as shown in Figure 10‐4. 196 VMware, Inc. Chapter 10 Securing an ESX Server 3 Configuration Figure 10-4. Sample VLAN Layout Host 1 vSwitch VM0 VM1 VM2 VM3 VM4 VM5 Broadcast Domain A VM8 VLAN B VLAN A Router Host 2 vSwitch vSwitch Switch 1 VM6 VM7 Broadcast Domain B Host 3 vSwitch VM9 Switch 2 VM10 VM11 Host 4 Multiple VLANs on the same virtual switch vSwitch VM12 VLAN B VM13 VLAN A VM14 VLAN B Broadcast Domains A and B In this configuration, all employees in the accounting department use virtual machines  in VLAN A and the employees in sales use virtual machines in VLAN B.  The router forwards packets containing accounting data to the switches. These packets  are tagged for distribution to VLAN A only. Therefore, the data is confined to Broadcast  Domain A, and cannot be routed to Broadcast Domain B unless the router is configured  to do so.  This VLAN configuration prevents the sales force from intercepting packets destined  for the accounting department. It also prevents the accounting department from  receiving packets intended for the sales group. The virtual machines serviced by a  single virtual switch can be in different VLANs. VMware, Inc. 197 ESX Server 3 Configuration Guide Security Considerations for vSwitches and VLANs ESX Server 3 features a complete IEEE 802.1q‐compliant VLAN implementation. The  way you set up VLANs to secure parts of a network depends on factors such as the  guest operating system you install, the way your network equipment is configured, and  so forth. While VMware cannot make specific recommendations on how to set up  VLANs, consider the following factors when using a VLAN deployment as part of your  security enforcement policy:  Treat VLANs as part of a broader security implementation – VLANs are an  effective means of controlling where and how widely data is transmitted within  the network. If an attacker gains access to the network, the attack is likely to be  limited to the VLAN that served as the entry point, lessening the risk to the  network as a whole.  VLANs provide protection only in that they control how data is routed and  contained after it passes through the switches and enters the network. You can use  VLANs to help secure Layer 2 of your network architecture—the data link layer.  However, configuring VLANs doesn’t protect the physical layer of your network  model or any of the other layers. Even if you create VLANs, provide additional  protection by securing your hardware (routers, hubs, and so forth) and encrypting  data transmissions. VLANs are not a substitute for firewalls in your virtual machine configurations.  Most network configurations that include VLANs also include software firewalls.  If you include VLANs in your virtual network, be sure that any firewalls you install  are VLAN‐aware.  Be sure your VLANs are properly configured – Equipment misconfiguration and  network hardware, firmware, or software defects can make a VLAN susceptible to  VLAN‐hopping attacks. VLAN hopping occurs when an attacker with authorized  access to one VLAN creates packets that trick physical switches into transmitting  the packets to another VLAN that the attacker is not authorized to access.  Vulnerability to this type of attack usually results from a switch being  misconfigured for native VLAN operation, in which the switch can receive and  transmit untagged packets.  To help prevent VLAN hopping, keep your equipment up to date by installing  hardware and firmware updates as they become available. Also, follow your  vendor’s best practice guidelines when you configure your equipment. VMware virtual switches do not support the concept of a native VLAN. All data  passed on these switches is appropriately tagged. However, because other  switches in the network might be configured for native VLAN operation, VLANs  configured with virtual switches can still be vulnerable to VLAN hopping.  198 VMware, Inc. Chapter 10 Securing an ESX Server 3 Configuration If you plan to use VLANs to enforce network security, VMware recommends that  you disable the native VLAN feature for all switches unless you have a compelling  need to operate some of your VLANs in native mode. If you need to use native  VLAN, pay attention to your switch vendor’s configuration guidelines for this  feature.  Create a separate VLAN or virtual switch for communication between  management tools and the service console – Whether you use a management  client or the command line, all configuration tasks for ESX Server 3 are performed  through the service console, including configuring storage, controlling aspects of  virtual machine behavior, and setting up virtual switches or virtual networks.  Because the service console is the point of control for ESX Server 3, safeguarding it  from misuse is crucial.  VMware ESX Server 3 management clients use authentication and encryption to  prevent unauthorized access to the service console, other services might not offer  the same protection. If attackers gain access to the service console, they are free to  reconfigure many attributes of the ESX Server 3 host. For example, they can change  the entire virtual switch configuration, change authorization methods, and so  forth. Network connectivity for the service console is established through virtual  switches. To provide better protection for this critical ESX Server 3 component,  VMware recommends that you isolate the service console by using one of the  following methods:  Create a separate VLAN for management tool communication with the  service console.   Configure network access for management tool connections with the service  console through a single virtual switch and one or more uplink ports. Both methods prevent anyone without access to the service console VLAN or  virtual switch from seeing traffic to and from the service console. They also prevent  attackers from sending any packets to the service console. As an alternative, you  can choose to configure the service console on a separate physical network  segment instead. Physical segmentation provides a degree of additional security  because it is less prone to later misconfiguration In addition to setting up a separate VLAN or virtual switch for management tool  communication with the service console, you should set up separate a VLAN or  virtual switch for VMotion and for network attached storage.  VMware, Inc. 199 ESX Server 3 Configuration Guide If your configuration includes an iSCSI SAN configured directly through the host  rather than through a hardware adapter, you should create a separate virtual  switch that provides shared network connectivity for the service console and for  iSCSI. This second network connection for the service console is in addition to the  primary service console network connection that you use for management tool  communications. The second service console network connection supports iSCSI  activities only, and you should not use it for any management activities or  management tool communications. Virtual Switch Protection and VLANs VMware virtual switches provide safeguards against certain threats to VLAN security.  Because of the way that virtual switches are designed, they protect VLANs against a  variety of attacks, many of which involve VLAN hopping. Having this protection does  not guarantee that your virtual machine configuration is invulnerable to other types of  attacks. For example, virtual switches do not protect the physical network against these  attacks, just the virtual network.  The following list gives you an idea of some attacks that virtual switches and VLANs  can protect against.   MAC flooding – Floods a switch with packets that contain MAC addresses tagged  as having come from different sources. Many switches use a content‐addressable  memory (CAM) table to learn and store the source address for each packet. When  the table is full, the switch can enter a fully open state in which every incoming  packet is broadcast on all ports, letting the attacker see all of the switch’s traffic.  This state might result in packet leakage across VLANs. While VMware virtual switches store a MAC address table, they don’t get the MAC  addresses from observable traffic and are not vulnerable to this type of attack.  802.1q and ISL tagging attacks – Force a switch to redirect frames from one VLAN  to another by tricking the switch into acting as a trunk and broadcasting the traffic  to other VLANs. VMware virtual switches don’t perform the dynamic trunking required for this  type of attack and, therefore, are not vulnerable. 200 VMware, Inc. Chapter 10 Securing an ESX Server 3 Configuration  Double‐encapsulation attacks – Occur when an attacker creates a  double‐encapsulated packet in which the VLAN identifier in the inner tag is  different from the VLAN identifier in the outer tag. For backward compatibility,  native VLANs strip the outer tag from transmitted packets unless configured to do  otherwise. When a native VLAN switch strips the outer tag, only the inner tag is  left, and that inner tag routes the packet to a different VLAN than the one  identified in the now‐missing outer tag. VMware virtual switches drop any double‐encapsulated frames that a virtual  machine attempts to send on a port configured for a specific VLAN. Therefore,  they are not vulnerable to this type of attack.  Multicast brute‐force attacks – Involve sending large numbers of multicast frames  to a known VLAN almost simultaneously in hopes of overloading the switch so  that it mistakenly allows some of the frames to broadcast to other VLANs. VMware virtual switches do not allow frames to leave their correct broadcast  domain (VLAN) and are not vulnerable to this type of attack.  Spanning‐tree attacks – Target Spanning‐Tree Protocol (STP), which is used to  control bridging between parts of the LAN. The attacker sends Bridge Protocol  Data Unit (BPDU) packets that attempt to change the network topology,  establishing themselves as the root bridge. As the root bridge, the attacker can sniff  the contents of transmitted frames. VMware virtual switches don’t support STP and are not vulnerable to this type of  attack.  Random frame attacks – Involve sending large numbers of packets in which the  source and destination addresses stay the same, but in which fields are randomly  changed in length, type, or content. The goal of this attack is to force packets to be  mistakenly rerouted to a different VLAN. VMware virtual switches are not vulnerable to this type of attack. Because new security threats develop over time, do not consider this an exhaustive list  of attacks. Regularly check VMware security resources on the Web  (http://www.vmware.com/support/security.html) to learn about security, recent  security alerts, and VMware security tactics. VMware, Inc. 201 ESX Server 3 Configuration Guide Securing Virtual Switch Ports As with physical network adapters, a virtual network adapter can send frames that  appear to be from a different machine or impersonate another machine so that it can  receive network frames intended for that machine. Also, like physical network  adapters, a virtual network adapter can be configured so that it receives frames targeted  for other machines. When you create a virtual switch for your network, you add port groups to impose a  policy configuration for the virtual machines, storage systems, and so forth attached to  the switch. You create virtual ports through the VI Client. As part of adding a port or port group to a virtual switch, the VI Client configures a  security profile for the port. You can use this security profile to ensure that ESX Server 3  prevents the guest operating systems for its virtual machines from impersonating other  machines on the network. This security feature is implemented so that the guest  operating system responsible for the impersonation does not detect that the  impersonation was prevented.  The security profile determines how strongly you enforce protection against  impersonation and interception attacks on virtual machines. To correctly use the  settings in the security profile, you need to understand the basics of how virtual  network adapters control transmissions and how attacks are staged at this level. Each virtual network adapter has its own MAC address assigned when the adapter is  created. This address is called the initial MAC address. Although the initial MAC  address can be reconfigured from outside the guest operating system, it cannot be  changed by the guest operating system. In addition, each adapter has an effective MAC  address that filters out incoming network traffic with a destination MAC address  different from the effective MAC address. The guest operating system is responsible for  setting the effective MAC address and typically matches the effective MAC address to  the initial MAC address. When sending packets, an operating system typically places its own network adapterʹs  effective MAC address in the source MAC address field of the Ethernet frame. It also  places the MAC address for the receiving network adapter in the destination MAC  address field. The receiving adapter accepts packets only when the destination MAC  address in the packet matches its own effective MAC address.  202 VMware, Inc. Chapter 10 Securing an ESX Server 3 Configuration Upon creation, a network adapter’s effective MAC address and initial MAC address are  the same. The virtual machine’s operating system can alter the effective MAC address  to another value at any time. If an operating system changes the effective MAC address,  its network adapter then receives network traffic destined for the new MAC address.  The operating system can send frames with an impersonated source MAC address at  any time. Thus, an operating system can stage malicious attacks on the devices in a  network by impersonating a network adapter that the receiving network authorizes. You can use virtual switch security profiles on ESX Server 3 hosts to protect against this  type of attack by setting the following options:  MAC address changes – By default, this option is set to Accept, meaning that the  ESX Server 3 host accepts requests to change the effective MAC address to other  than the initial MAC address. The MAC Address Changes option setting affects  traffic that a virtual machine receives. To protect against MAC impersonation, you can set this option to Reject. If you do,  the ESX Server 3 host does not honor requests to change the effective MAC address  to anything other than the initial MAC address. Instead, the port that the virtual  adapter used to send the request is disabled. As a result, the virtual adapter does  not receive any more frames until it changes the effective MAC address to match  the initial MAC address. The guest operating system does not detect that the MAC  address change was not honored. NOTE   In some situations, you might have a legitimate need for more than one  adapter to have the same MAC address on a network—for example, if you are  using Microsoft Network Load Balancing in unicast mode. When Microsoft  Network Load Balancing is used in the standard multicast mode, adapters do not  share MAC addresses.  Forged transmissions – By default, this option is set to Accept, meaning the  ESX Server 3 host does not compare source and effective MAC addresses. The  Forged Trasmits option setting affects traffic transmitted from a virtual machine. To protect against MAC impersonation, you can set this option to Reject. If you do,  the ESX Server 3 host compares the source MAC address being transmitted by the  operating system with the effective MAC address for its adapter to see if they  match. If the addresses don’t match, ESX Server 3 drops the packet. The guest operating system does not detect that its virtual network adapter cannot  send packets by using the impersonated MAC address. The ESX Server 3 host  intercepts any packets with impersonated addresses before they are delivered, and  the guest operating system might assume that the packets are dropped.  VMware, Inc. 203 ESX Server 3 Configuration Guide  Promiscuous mode operation – By default, this option is set to Reject, meaning  that the virtual network adapter cannot operate in promiscuous mode.  Promiscuous mode eliminates any reception filtering that the virtual network  adapter would perform, so that the guest operating system receives all traffic  observed on the wire. Although promiscuous mode can be useful for tracking network activity, it is an  insecure mode of operation because any adapter in promiscuous mode has access  to the packets regardless of whether some of the packets should be received only  by a particular network adapter. This means that an administrator or root user  within a virtual machine can potentially view traffic destined for other guest or  host operating systems.  NOTE   In some situations, you might have a legitimate need to configure a virtual  switch to operate in promiscuous mode—for example, if you are running network  intrusion detection software or a packet sniffer. To change any of these default settings for a port, modify the security profile by editing  virtual switch settings in the VI Client. For information on editing these settings, see  “Virtual Switch Policies” on page 50. Securing iSCSI Storage The storage you configure for an ESX Server 3 host might include one or more storage  area networks (SANs) that use iSCSI. iSCSI is a means of accessing SCSI devices and  exchanging data records by using TCP/IP protocol over a network port rather than  through a direct connection to a SCSI device. In iSCSI transactions, blocks of raw SCSI  data are encapsulated in iSCSI records and transmitted to the requesting device or user.  iSCSI SANs let you make efficient use of existing Ethernet infrastructures to provide  ESX Server 3 hosts access to storage resources that they can dynamically share. iSCSI  SANs provide an economical storage solution for environments that rely on a common  storage pool to serve numerous users. As with any networked system, your iSCSI SANs  can be subject to security breaches. When you configure iSCSI on an ESX Server 3 host,  you can take several measures to minimize security risks. NOTE   The requirements and procedures for securing an iSCSI SAN are similar for the  hardware iSCSI adapters you can use with ESX Server 3 hosts and for iSCSI configured  directly through the ESX Server 3 host. For information on configuring iSCSI adapters  and storage, see “iSCSI Storage” on page 110. 204 VMware, Inc. Chapter 10 Securing an ESX Server 3 Configuration Securing iSCSI Devices Through Authentication One means of securing iSCSI devices from unwanted intrusion is to require that the  ESX Server 3 host, or initiator, be authenticated by the iSCSI device, or target, whenever  the host attempts to access data on the target LUN. The goal of authentication is to  prove that the initiator has the right to access a target, a right granted when you  configure authentication.  You have two choices when you set up authentication for iSCSI SANs on the  ESX Server 3 host:  Challenge Handshake Authentication Protocol (CHAP) – You can configure the  iSCSI SAN to use CHAP authentication. In CHAP authentication, when the  initiator contacts an iSCSI target, the target sends a predefined ID value and a  random value, or key, to the initiator. The initiator then creates a one‐way hash  value that it sends to the target. The hash contains three elements: a predefined ID  value, the random value that the target sends, and a private value, or CHAP secret,  that the initiator and target share. When the target receives the hash from the  initiator, it creates its own hash value by using the same elements and compares it  to the initiator’s hash. If the results match, the target authenticates the initiator. ESX Server 3 supports one‐way CHAP authentication for iSCSI. It does not  support bi‐directional CHAP. In one‐way CHAP authentication, the target  authenticates the initiator, but the initiator does not authenticate the target. The  initiator has only one set of credentials, and all of the iSCSI targets use them. ESX Server 3 supports CHAP authentication at the HBA level only. It does not  support per‐target CHAP authentication for each, which enables you to configure  different credentials for each target to achieve greater target refinement.  Disabled – You can configure the iSCSI SAN to use no authentication.  Communications between the initiator and target are still authenticated in a  rudimentary way because the iSCSI target devices are typically set up to  communicate with specific initiators only.  Choosing not to enforce more stringent authentication can make sense if your  iSCSI storage is housed in one location and you create a dedicated network or  VLAN to service all your iSCSI devices. The iSCSI configuration is secure because  it is isolated from any unwanted access, much as a Fibre Channel SAN would be.  As a basic rule, disable authentication only if you are willing to risk an attack to the  iSCSI SAN or cope with problems that result from human error.  ESX Server 3 does not support Kerberos, Secure Remote Protocol (SRP), or public‐key  authentication methods for iSCSI. Additionally, it does not support IPsec  authentication and encryption.  VMware, Inc. 205 ESX Server 3 Configuration Guide Use the VI Client to determine whether authentication is currently being performed  and to configure the authentication method. To check the authentication method 1 Log in to the VI Client and select the server from the inventory panel.  2 Click the Configuration tab and click Storage Adapters.  3 Select the iSCSI adapter to check and click Properties to open the iSCSI Initiator  Properties dialog box.  4 Click CHAP Authentication.  If CHAP Name shows a name—often the iSCSI initiator name, the iSCSI SAN is  using CHAP authentication. NOTE   If CHAP Name shows Not Specified, the iSCSI SAN is not using CHAP  authentication. 5 206 Click Close. VMware, Inc. Chapter 10 Securing an ESX Server 3 Configuration To configure iSCSI for CHAP authentication 1 Log in to the VI Client and select the server from the inventory panel. 2 Click the Configuration tab and click Storage Adapters.  3 Select the iSCSI adapter and click Properties to open the iSCSI Initiator Properties  dialog box.  4 Click CHAP Authentication > Configure to open the CHAP Authentication  dialog box.  5 Click Use the following CHAP credentials.  6 Perform one of the following actions: 7  To set the CHAP name to the iSCSI adapter name, select Use initiator name.  To set the CHAP name to anything other than the iSCSI adapter name,  deselect Use initiator name and enter a name of up to 255 alphanumeric  characters in the CHAP Name field. Enter a CHAP secret to be used as part of authentication.  The secret you enter is a text string.  The VI Client doesn’t impose a minimum or maximum length for the CHAP secret  you enter. However, some iSCSI storage devices require that the secret exceed a  minimum number of characters or have limitations on the character types you can  use. To determine the requirements, check the manufacturer’s documentation. 8 VMware, Inc. Click OK. 207 ESX Server 3 Configuration Guide To disable iSCSI authentication 1 Log in to the VI Client and select the server from the inventory panel. 2 Click the Configuration tab and click Storage Adapters.  3 Select the iSCSI adapter and click Properties to open the iSCSI Initiator Properties  dialog box.  4 Click CHAP Authentication > Configure to open the CHAP Authentication  dialog box.  5 Select Disable CHAP authentication. 6 Click OK. Protecting an iSCSI SAN When you plan your iSCSI configuration, take measures to improve the overall security  of the iSCSI SAN. Your iSCSI configuration is only as secure as your IP network, so by  enforcing good security standards when you set up your network, you help safeguard  your iSCSI storage.  The following are some specific suggestions:  Protect transmitted data – A primary security risk in iSCSI SANs is that an attacker  might sniff transmitted storage data.  VMware recommends that you take additional measures to prevent attackers from  easily seeing iSCSI data. Neither the hardware iSCSI adapter nor the ESX Server 3  host iSCSI initiator encrypts the data they transmit to and from the targets, making  the data more vulnerable to sniffing attacks.  Allowing your virtual machines to share virtual switches and VLANs with your  iSCSI configuration potentially exposes iSCSI traffic to misuse by a virtual machine  attacker. To help ensure that intruders can’t listen to iSCSI transmissions, make  sure that none of your virtual machines can see the iSCSI storage network.  If you use a hardware iSCSI adapter, you can accomplish this by making sure that  the iSCSI adapter and ESX Server 3 physical network adapter are not inadvertently  connected outside the host by virtue of sharing a switch or some other means. If  you configure iSCSI directly through the ESX Server 3 host, you can accomplish  this by configuring iSCSI storage through a different virtual switch than the one  used by your virtual machines, as shown in Figure 10‐5. 208 VMware, Inc. Chapter 10 Securing an ESX Server 3 Configuration Figure 10-5. iSCSI Storage on a Separate Virtual Switch If you configure iSCSI directly through the host rather than through a hardware  adapter, you must create two network connections for the service console within  the virtual network setup. You configure the first service console network  connection on its own virtual switch and use it exclusively for management tool  connectivity (vSwitch0 in the figure). You configure the second service console  network connection so that it shares the virtual switch you use for iSCSI  connectivity (vSwitch2 in the figure). The second service console network  connection supports iSCSI activities only. Do not use it for any management  activities or management tool communications. To enforce a degree of separation  between the iSCSI and service console on the shared virtual switch, configure them  on different VLANs. NOTE   Do not configure the default gateway for the service console on the virtual  switch you use for iSCSI connectivity. Configure it on the virtual switch you use for  management tool connectivity instead. In addition to protecting the iSCSI SAN by giving it a dedicated virtual switch,  consider configuring your iSCSI SAN on its own VLAN. Placing your iSCSI  configuration on a separate VLAN ensures that no devices other than the iSCSI  adapter have visibility into transmissions within the iSCSI SAN.  VMware, Inc. 209 ESX Server 3 Configuration Guide  Secure iSCSI ports – When you run iSCSI devices, the ESX Server 3 host doesn’t  open any ports that listen for network connections. This measure reduces the  chances that an intruder can break into the ESX Server 3 host through spare ports  and gain control over the host. Therefore, running iSCSI doesn’t present any  additional security risks at the ESX Server 3 host end of the connection.  Any iSCSI target device that you run must have one or more open TCP ports used  to listen for iSCSI connections. If any security vulnerabilities exist in the iSCSI  device software, your data can be at risk through no fault of ESX Server 3. To lower  this risk, install all security patches that your storage equipment manufacturer  provides and limit the devices connected to the iSCSI network. 210 VMware, Inc. 11 Authentication and User Management 11 This chapter explains how ESX Server 3 handles user authentication and shows you  how to set up user and group permissions. In addition, it discusses encryption for  connections to the VI Client, SDK, and VI Web Access, as well as how to configure a  delegate user name for transactions with NFS storage. This chapter discusses the following topics:  “Securing ESX Server 3 Through Authentication and Permissions” on page 211  “Encryption and Security Certificates for ESX Server 3” on page 225  “Virtual Machine Delegates for NFS Storage” on page 232 Securing ESX Server 3 Through Authentication and Permissions ESX Server 3 uses the Pluggable Authentication Modules (PAM) structure for  authentication when users access the ESX Server 3 host using the VI Client, VI Web  Access, or the service console. The PAM configuration for VMware services is located  in /etc/pam.d/vmware-authd, which stores paths to authentication modules. The default installation of ESX Server 3 uses /etc/passwd authentication, just as Linux  does, but you can configure ESX Server 3 to use another distributed authentication  mechanism. If you plan to use a third‐party authentication tool instead of the  ESX Server 3 default implementation, see the vendor documentation for instructions.  As part of setting up third‐party authentication, you might need to update the  /etc/pam.d/vmware-authd file with new module information. VMware, Inc. 211 ESX Server 3 Configuration Guide Every time a VI Client or VirtualCenter user connects to an ESX Server 3 host, the  xinetd process connects with the VMware Host Agent (vmware-hostd) process. The  vmware-hostd process receives the user name and password from the client and  forwards them to the PAM module to perform the authentication.  Figure 11‐1 shows a basic example of how ESX Server 3 authenticates transactions from  the VI Client.  Figure 11-1. Authentication for VI Client Communications with ESX Server 3 VI Client management functions console user name/password authentication ticket-based authentication ESX Server SW service console VMkernel vmware-hostd virtual machine vmkauthd ESX Server authentication transactions with VI Web Access and third‐party network  management clients are similarly direct interactions with the vmware-hostd process. To make sure that authentication works efficiently for your site, you might need to  perform basic tasks such as setting up users, groups, permissions, and roles,  configuring user attributes, adding your own certificates, determining whether you  want to use SSL, and so forth.  212 VMware, Inc. Chapter 11 Authentication and User Management About Users, Groups, Permissions, and Roles Access to an ESX Server host and its resources is granted when a known user with  appropriate permissions logs in to the host with a password that matches the password  stored for that user. VirtualCenter uses a similar approach when determining whether  to grant access to a user. VirtualCenter and ESX Server hosts determine the level of  access for the user based on the permissions assigned to the user. For example, one user  might have permissions that allows them to create virtual machines on the host and  another user might have permissions that allow them to power on virtual machines but  not create them.  The combination of user name, password, and permissions is the mechanism by which  VirtualCenter and ESX Server 3 hosts authenticate a user for access and authorize the  user to perform activities. To support this mechanism, the VirtualCenter and  ESX Server hosts maintain lists of authorized users, their passwords, and the  permissions assigned to each user. VirtualCenter and ESX Server hosts deny access  under the following circumstances:  A user not in the user list attempts to log in.  A user enters the wrong password.   A user is in the list but was not assigned permissions.  A user who successfully logged in attempts operations that they do not have  permission to perform. As part of managing ESX Server hosts and VirtualCenter, you need to develop user and  permission models, which are basic plans for how to handle particular types of users  and how to design your permissions. In developing your user and permission models,  be aware that:  ESX Server 3 and VirtualCenter use sets of privileges, or roles, to control which  operations individual users or groups can perform. ESX Server 3 and  VirtualCenter provide you with a set of pre‐established roles, but you can also  create new ones.  You can manage users more easily by assigning them to groups. If you create  groups, you can apply a role to the group, and this role is inherited by all the users  in the group. VMware, Inc. 213 ESX Server 3 Configuration Guide Understanding Users A user is an individual authorized to log in to either an ESX Server 3 host or to  VirtualCenter. ESX Server 3 users fall into two categories: those who can access the  ESX Server 3 host through VirtualCenter and those who can access the ESX Server 3  host by directly logging in to the host from the VI Client, VI Web Access, a third‐party  client, or a command shell. These two categories draw users from different sources.  Authorized VirtualCenter – Are included in the Windows domain list that  VirtualCenter references or are local Windows users on the VirtualCenter host.  You cannot use VirtualCenter to manually create, remove, or otherwise change  users. To manipulate the user list or change user passwords, you must do so  through the tools you use to manage your Windows domain. Any changes you make to the Windows domain are reflected in VirtualCenter.  However, because you cannot directly manage users in VirtualCenter, the user  interface doesn’t provide a user list for you to review. The only time you work with  user and group lists is when you select users and groups during role assignment.  You notice these changes only when you select users to configure permissions.  Direct‐access users – Authorized to work directly on an ESX Server 3 host are  added to the internal user list by default when ESX Server 3 is installed or by a  system administrator after installation.  If you log in to the host as an administrator, you can perform a variety of  management activities for these users, such as changing passwords, group  memberships, permissions, and so forth. You can also add and remove users.  The user list that VirtualCenter maintains is completely separate from the user list that  the ESX Server 3 host maintains. Even if the lists a host and VirtualCenter maintain  appear to have common users (for instance, a user called devuser), treat these users as  separate users who happen to have the same name. The attributes of devuser in  VirtualCenter, including permissions, passwords, and so forth are separate from the  attributes of devuser on the ESX Server 3 host. If you log in to VirtualCenter as devuser,  you might have permission to view and delete files from a datastore, whereas if you log  in to an ESX Server 3 host as devuser, you might not. Because of the confusion that duplicate naming can cause, VMware recommends that  you check the VirtualCenter user list before you create ESX Server 3 host users so that  you can avoid duplicating names. To check for VirtualCenter users, review the  Windows domain list. 214 VMware, Inc. Chapter 11 Authentication and User Management Understanding Groups You can more efficiently manage some user attributes by creating groups. A group is a  set of users that you want to manage through a common set of rules and permissions.  When you assign permissions to a group, all users in the group inherit them, and you  do not have to work with the user profiles individually. Therefore, using groups can  significantly reduce the time it takes to set up your permissions model and improve  future scalability.  As an administrator, decide how to structure groups to achieve your security and usage  goals. For example, three part‐time sales team members work different days, and you  want them to share a single virtual machine but not use the virtual machines belonging  to sales managers. In this case, you might create a group called SalesShare that includes  the three sales people: Mary, John, and Tom. You might then give the SalesShare group  permission to interact with only one object, Virtual Machine A. Mary, John, and Tom  inherit these permissions and are able to power up Virtual Machine A, start console  sessions on Virtual Machine A, and so forth. They cannot perform these actions on the  sales managers’ virtual machines: Virtual Machines B, C, and D. The group lists in VirtualCenter and an ESX Server 3 host are drawn from the same  sources as their respective user lists. If you are working through VirtualCenter, the  group list is called from the Windows domain. If you are logged in to an ESX Server 3  host directly, the group list is called from a table that the host maintains. All the  recommendations for how you treat group lists are the same as those for user lists. Understanding Permissions For ESX Server 3 and VirtualCenter, permissions are defined as access roles that consist  of a user and the user’s assigned role for an object such as a virtual machine or  ESX Server 3 host. Permissions grant users the right to perform specific activities and  manage specific objects on an ESX Server 3 host or, if users are working from  VirtualCenter, all VirtualCenter‐managed objects. For example, to configure memory  for an ESX Server 3 host, you must have a permission that grants host configuration  privileges. VMware, Inc. 215 ESX Server 3 Configuration Guide Most VirtualCenter and ESX Server 3 users have limited ability to manipulate the  objects associated with the host. However, users in the Administrator role have full  access rights and permissions on all virtual objects such as datastores, hosts, virtual  machines, and resource pools. By default, the Administrator role is granted to the root  user; if VirtualCenter manages the host, vpxuser is also an Administrator user.  Administrator users have the following permissions:  root – The root user can perform a complete range of control activities on the  specific ESX Server 3 host that they are logged in to, including manipulating  permissions, creating groups and users, working with events, and so forth. A root  user logged in to one ESX Server 3 host cannot control the activities of any other  host in the broader ESX Server 3 deployment. For security reasons, you might not want to use the root user in the Administrator  role. In this case, you can change permissions after installation so that the root user  no longer has administrative privileges or you can delete the root user’s access  permissions altogether through the VI Client as described in the “Managing Users,  Groups, Permissions, and Roles” chapter of Basic System Administration. If you do  so, you must first create another permission at the root level that has a different  user assigned to the Administrator role.  Assigning the Administrator role to a different user helps you maintain security  through traceability. The VI Client logs all actions that the Administrator role user  initiates as events, providing you with an audit trail. You can use this feature to  improve accountability among the various users who act as administrators for the  host. If all the administrators log in to the host as the root user, you cannot tell  which administrator performed an action. If, instead, you create multiple  permissions at the root level—each associated with a different user or user  group—you can track the actions of each administrator or administrative group. After you create an alternative Administrator user, you can safely delete the root  user’s permissions or change its role to limit its privileges. If you delete or change  the root user’s permissions, you must use the new user you created as the host  authentication point when you bring the host under VirtualCenter management.  See “Understanding Roles” on page 218. NOTE   Configuration commands that you run through the command‐line interface  (esxcfg commands) do not perform an access check. Therefore, even if you limit  the root user’s privileges, this does not affect what that user can do using the  command line interface commands. 216 VMware, Inc. Chapter 11 Authentication and User Management  vpxuser – This user is VirtualCenter acting as an entity with Administrator rights  on the ESX Server 3 host, allowing it to manage activities for that host. vpxuser is  created at the time that an ESX Server 3 host is attached to VirtualCenter. It is not  present on the ESX Server 3 host unless the host is being managed through  VirtualCenter. When an ESX Server 3 host is managed through VirtualCenter, VirtualCenter has  Administrator privileges on the host. For example, VirtualCenter can move virtual  machines to and from hosts and perform configuration changes needed to support  virtual machines.  The VirtualCenter administrator, through vpxuser, can perform most of the same  tasks on the host as the root user and also schedule tasks, work with templates, and  so forth. However, you cannot perform certain activities as a VirtualCenter  administrator. These activities, which include directly creating, deleting, or editing  users and groups for ESX Server 3 hosts, can be performed only by a user with  Administrator permissions directly on each ESX Server 3 host.  CAUTION   Do not change vpxuser in any way and do not change its permissions.  If you do so, you might experience problems in working with the ESX Server host  through VirtualCenter. If you are acting in the Administrator role on an ESX Server 3i host, you can grant  permissions to individual users and groups on that host If you are acting in the  Administrator role in VirtualCenter, you can grant permissions to any user or group  included in the Windows domain list that VirtualCenter references. VirtualCenter registers any selected Windows domain user or group through the  process of assigning permissions. By default, all users who are members of the local  Windows Administrators group on the VirtualCenter Server are granted the same  access rights as any user assigned to the Administrator role. Users who are members of  the Administrators group can log in as individuals and have full access. For security reasons, consider removing the Windows Administrators group from the  Administrator role. You can change permissions after installation so the Windows  Administrators group does not have administrative privileges. Alternately you can use  VI Client to delete the Windows Administrators group access permissions. If you delete  Windows Administrators access permissions, you must first create another permission  at the root level that has a different user assigned to the Administrator role. VMware, Inc. 217 ESX Server 3 Configuration Guide The method you use to configure permissions directly on an ESX Server 3i host is  identical to the method you use to configure permissions in VirtualCenter. Also, the list  of privileges is the same for ESX Server 3i and VirtualCenter.  For information on configuring permissions and to read about the privileges you can  assign, see Basic System Administration. Understanding Roles VirtualCenter and ESX Server grant access to objects only to users who are assigned  permissions for the object. When you assign a user or group permissions for the object,  you do so by pairing the user or group with a role. A role is a predefined set of  privileges.  ESX Server hosts provide three default roles, and you cannot change the privileges  associated with these roles. Each subsequent default role includes the privileges of the  previous role. For example, the Administrator role inherits the privileges of the Read  Only role. Roles you create yourself do not inherit privileges from any of the default  roles. The default roles are:  No Access – Users assigned this role for an object cannot view or change the object  in any way. For example, a user who has a No Access role for a particular virtual  machine cannot see the virtual machine in the VI Client inventory when they log  in to the ESX Server host. With a No Access role for a particular object, a user can  select the VI Client tabs associated with the no‐access object, but the tab displays  no content. For example, if the user does not have access to any virtual machines,  they can select the Virtual Machines tab but will not see a virtual machine listing  on the tab or any status information—the table is blank. The No Access role is the default assigned to any user or group you create on an  ESX Server 3 host. You can elevate or lower a newly created user’s or group’s role  on an object‐by‐object basis. The root user and vpxuser are the only users not assigned the No Access role by  default. Instead, they are assigned the Administrator role.  You can delete the root user’s permissions altogether or change its role to No  Access as long as you first create a replacement permission at the root level with  the Administrator role and associate this role with a different user. If you delete or  change the root user’s permissions, you must use the new user you created as the  host authentication point when you bring the host under VirtualCenter  management. 218 VMware, Inc. Chapter 11 Authentication and User Management  Read Only – Users assigned this role for an object are allowed to view the state of  the object and details about the object.  With this role, a user can view virtual machine, host, and resource pool attributes.  The user cannot view the remote console for a host. All actions through the menus  and toolbars are disallowed.   Administrator – Users assigned this role for an object are allowed to view and  perform all actions on the object. This role also includes all permissions inherent in  the Read Only role. You can create custom roles by using the role‐editing facilities in the VI Client to create  privilege sets that match your user needs. If you use the VI Client connected to  VirtualCenter to manage your ESX Server 3 hosts, you have additional roles to choose  from in VirtualCenter. Also, the roles you create directly on an ESX Server 3 host are not  accessible within VirtualCenter. You can work with these roles, only if you log in to the  host directly from the VI Client.  If you manage ESX Server 3 hosts through VirtualCenter, maintaining custom roles in  the host and VirtualCenter can result in confusion and misuse. In this type of  configuration, VMware recommends that you maintain custom roles only in  VirtualCenter. For information on creating, altering, and deleting roles as well as a  discussion of additional roles available in VirtualCenter, see Basic System  Administration. Working with Users and Groups on ESX Server 3 Hosts If you are directly connected to an ESX Server 3 host through the VI Client, you can  create, edit, and delete users and groups. These users and groups are visible in the  VI Client whenever you log in to the ESX Server 3 host, but are not available if you log  in to VirtualCenter. Viewing and Exporting Users and Group Information You work with users and groups through the Users & Groups tab in the VI Client. This  tab displays a Users table or Groups table depending on whether you click Users or  Groups. You can also create roles and set permissions through a direct connection to the  ESX Server 3 host. Because these tasks are more widely performed in VirtualCenter, see  Basic System Administration for information on working with permissions and roles. VMware, Inc. 219 ESX Server 3 Configuration Guide Figure 11‐2 shows the Users table. The Groups table is similar. Figure 11-2. Users Table You can sort the lists according to column, show and hide columns, and export the list  in formats you can use when preparing reports or publishing user or group lists on  the Web. To view and sort ESX Server 3 users or groups 1 Log in to the VI Client through the ESX Server 3 host. 2 Select the server from the inventory panel.  3 Click the Users & Groups tab and click Users or Groups.  4 Perform any of these actions as appropriate:  To sort the table by any of the columns, click the column heading.  To show or hide columns, right‐click any of the column headings and select or  deselect the name of the column to hide.  To export data in the ESX Server 3 Users or Groups table 220 1 Log in to the VI Client through the ESX Server 3 host. 2 Select the server from the inventory panel.  3 Click the Users & Groups tab and click Users or Groups.  VMware, Inc. Chapter 11 Authentication and User Management 4 Determine how to sort the table, and hide or show columns according to the  information you want to see in the exported file.  5 Right‐click anywhere in the user table and click Export to open the Save As dialog  box. 6 Select a path, enter a filename, and select the file type.  7 Click OK. Working with the Users Table You can add users to the Users table for an ESX Server 3 host, remove users, and change  various user attributes such as password and group memberships. When you perform  these activities, you are altering the internal user list the ESX Server 3 host maintains. To add a user to the ESX Server 3 Users table 1 Log in to the VI Client through the ESX Server 3 host. 2 Select the server from the inventory panel.  3 Click the Users & Groups tab and click Users.  VMware, Inc. 221 ESX Server 3 Configuration Guide 4 Right‐click anywhere in the Users table and click Add to open the Add New User  dialog box. 5 Enter a login, a user name, a numeric user ID (UID), and a password.  Specifying the user name and UID are optional. If you don’t specify the UID, the  VI Client assigns the next available UID. The password should meet the length and complexity requirements outlined in  “Password Restrictions” on page 241. However, the ESX Server 3 host checks for  password compliance only if you have switched to the pam_passwdqc.so plug‐in  for authentication. The password settings in the default authentication plug‐in,  pam_cracklib.so, are not enforced. 6 If you want the user to be able to access the ESX Server 3 host through a command  shell, select Grant shell access to this user. In general, do not grant shell access to ESX Server 3 host users unless you  determine that they have a justifiable need to access the host through a shell rather  than through the VI Client. Users that access the host only through the VI Client  do not need shell access. 222 VMware, Inc. Chapter 11 Authentication and User Management 7 For each existing group you want the user to be part of, enter the group name and  click Add. If you type a nonexistent group name, the VI Client warns you and does not add  the group to the Group membership list.  8 Click OK. The login and user name you entered now appear in the Users table. To modify the settings for a user 1 Log in to the VI Client through the ESX Server 3 host. 2 Select the server from the inventory panel.  3 Click the Users & Groups tab and click Users.  4 Right‐click the user to modify and click Edit to open the Edit User dialog box. 5 To change the user ID, enter a numeric user UID in the UID field. The VI Client assigns the UID when you first create the user. In most cases, this  assignment does not need to be changed.  6 Enter a new user name. 7 To change the user’s password, select Change Password and enter the new  password. The password should meet the length and complexity requirements outlined in  “Password Restrictions” on page 241. However, the ESX Server 3 host checks for  password compliance only if you switched to the pam_passwdqc.so plug‐in for  authentication. The password settings in the default authentication plugin,  pam_cracklib.so, are not enforced. 8 To change the user’s ability to access the ESX Server 3 host through a command  shell, select or deselect Grant shell access to this user. 9 To add the user to another group, enter the group name and click Add. If you type a nonexistent group name, the VI Client warns you and does not add  the group to the Group membership list.  10 To remove the user from a group, select the group name from the list and click  Remove.  11 Click OK. VMware, Inc. 223 ESX Server 3 Configuration Guide To remove a user from the ESX Server 3 Users table 1 Log on to the VI Client through the ESX Server 3 host. 2 Select the server from the inventory panel.  3 Click the Users & Groups tab and click Users.  4 Right‐click the user to remove and click Remove. CAUTION   Do not remove the root user. Working with the Groups Table You can add groups to the Groups table for an ESX Server 3 host, remove groups, and  add or remove group members. When you perform these activities, you are altering the  internal group list that the ESX Server 3 host maintains. To add a group to the ESX Server 3 Groups table 1 Log in to the VI Client through the ESX Server 3 host. 2 Select the server from the inventory panel.  3 Click the Users & Groups tab and click Groups.  4 Right‐click anywhere in the Groups table and click Add to open the Create New  Group dialog box. 5 Enter a group name and numeric group ID (GID) in the Group ID field. Specifying the GID is optional. If you don’t specify a GID, the VI Client assigns the  next available group ID.  6 For each user that you want as a group member, enter the user name and click Add. If you type a nonexistent user name, the VI Client warns you and does not add the  user to the Users in this group list.  7 Click OK. The group ID and group name you entered now appear in the Groups table. To add or remove users from a group 224 1 Log in to the VI Client through the ESX Server 3 host. 2 Select the server from the inventory panel.  3 Click the Users & Groups tab and click Groups.  VMware, Inc. Chapter 11 Authentication and User Management 4 Right‐click the group to modify and click Edit to open the Edit Group dialog box. 5 To add a user to the group, enter the user name and click Add. If you type a nonexistent user name, the VI Client warns you and does not add the  user to the Users in this group list.  6 To remove a user from the group, select the user name from the list and click  Remove.  7 Click OK. To remove a group from the ESX Server 3 Groups table 1 Log in to the VI Client through the ESX Server 3 host. 2 Select the server from the inventory panel.  3 Click the Users & Groups tab and click Groups.  4 Right‐click the group you want to remove and click Remove. CAUTION   Do not remove the root user. Encryption and Security Certificates for ESX Server 3 ESX Server supports SSL v3 and TLS v1, generally referred to here as SSL. SSL helps  secure communications. If SSL is enabled data is private, so it can not be read, and it is  protected, so it cannot be modified in transit without detection. All network traffic is  encrypted as long as the following conditions are true:  You did not change the Web proxy service to allow unencrypted traffic for the port.  Your service console firewall is configured for medium or high security. For  information on configuring the service console firewall, see “Service Console  Firewall Configuration” on page 237. (SEE UPDATE) SSL is not enabled by default, so network traffic is not encrypted unless  you take action. SSL does protect the initial connection between VI Clients and  VirtualCenter, but subsequent communications are not encrypted. To fully enable the  security provided by certificates in ESX Server 3, you must enable certificate checking  and install new certificates. VMware, Inc. 225 ESX Server 3 Configuration Guide To enable certificate checking 1 Log in to a VirtualCenter server using the VI Client. 2 Click Administration > Virtual Center Management Server Configuration. The Virtual Center Management Server Configuration dialog appears. 3 Click SSL Settings in the left pane and enable the Check host certificates  checkbox.  4 Click OK. (SEE UPDATE) To receive the full benefit of certificate checking, install new certificates.  The initial certificates are created by ESX Server and stored on the host. The certificates  used to secure your VirtualCenter and VI Web Access sessions are not signed by a  trusted certificate authority and, therefore, do not provide the authentication security  you might need in a production environment. For example, self‐signed certificates are  vulnerable to man‐in‐the‐middle attacks. If you intend to use encrypted remote  connections externally, consider purchasing a certificate from a trusted certificate  authority or use your own security certificate for your SSL connections. If the  self‐signed certificate is used, clients receive a warning about the certificate. To address this issue, install a certificate that is signed by a recognized certificate  authority. The default location for your certificate is /etc/vmware/ssl/ on the ESX Server 3 host.  The certificate consists of two files: the certificate itself (rui.crt) and the private‐key  file (rui.key).  226 VMware, Inc. Chapter 11 Authentication and User Management Adding Certificates and Modifying ESX Server 3 Web Proxy Settings When you add certificates for ESX Server 3, think about encryption and user security,  be aware of the following:  (SEE UPDATE) Avoid setting up certificates by using pass phrases. ESX Server 3 does  not handle pass phrases, also known as encrypted keys. If you set up a pass phrase,  ESX Server 3 processes cannot start correctly.  You can configure the Web proxy so that it searches for certificates in a location  other than the default location. This capability proves useful for companies that  prefer to centralize their certificates on a single machine so that multiple hosts can  use the certificates.  CAUTION   Certificates stored in a location other the ESX Server 3 host are unusable  if the host loses network connectivity. If certificate checking is enabled, you cannot  establish secure connections with guests.  To support encryption for user names, passwords, and packets, SSL is enabled by  default for VI Web Access and VMware Infrastructure SDK connections. To  configure these connections so that they don’t encrypt transmissions, disable SSL  for your VI Web Access connection or VMware Infrastructure SDK connection by  switching the connection from HTTPS to HTTP, as described in “To change  security settings for a Web proxy service” on page 228. Consider disabling SSL  only if you created a fully trusted environment for these clients, where firewalls are  in place and transmissions to and from the host are fully isolated. Disabling SSL  can improve performance, because you avoid the overhead required to perform  encryption.   To protect against misuse of ESX Server 3 services such as the internal Web server  that hosts VI Web Access, most internal ESX Server 3 services are accessible only  through port 443, the port used for HTTPS transmission. Port 443 acts as a reverse  proxy for ESX Server 3. You can see a list of services on ESX Server 3 through an  HTTP welcome page, but you can’t directly access these services without proper  authorization. You can change this configuration so that individual services are  directly accessible through HTTP connections. VMware recommends that you not  make this change unless you are using ESX Server 3 in a fully trusted environment.  When you upgrade VirtualCenter and VI Web Access, the certificate remains in  place. If you remove VirtualCenter and VI Web Access, the certificate directory is  not removed from the service console. (SEE UPDATE) VMware, Inc. 227 ESX Server 3 Configuration Guide To configure the Web proxy to search for certificates in nondefault locations 1 Log in to the service console as the root user. 2 Change directories to /etc/vmware/hostd/. 3 Use a text editor to open the proxy.xml file and find the following XML segment: /etc/vmware/ssl/rui.key /etc/vmware/ssl/rui.crt 4 Replace /etc/vmware/ssl/rui.key with the absolute path to the private key file  that you received from your trusted certificate authority.  This path can be on the ESX Server 3 host or on a centralized machine on which  you store certificates and keys for your company. NOTE   Leave the  and  XML tags in place. 5 Replace /etc/vmware/ssl/rui.crt with the absolute path to the certificate file  that you received from your trusted certificate authority.  CAUTION   Do not delete the original rui.key and rui.crt files. The ESX Server  host uses these files. 6 Save your changes and close the file. 7 Enter the following command to restart the vmware-hostd process: service mgmt-vmware restart To change security settings for a Web proxy service 228 1 Log in to the service console as the root user. 2 Change directories to /etc/vmware/hostd/. VMware, Inc. Chapter 11 Authentication and User Management 3 Use a text editor to open the proxy.xml file. Contents of the file typically appears  as follows: <_length>6 <_type>vim.ProxyService.EndpointSpec[] <_type>vim.ProxyService.NamedPipeServiceSpec httpsWithRedirect /var/run/vmware/proxy-webserver / <_type>vim.ProxyService.NamedPipeServiceSpec httpsWithRedirect /var/run/vmware/proxy-sdk /sdk <_type>vim.ProxyService.LocalServiceSpec httpsWithRedirect 8080 /ui <_type>vim.ProxyService.NamedPipeServiceSpec httpsOnly /var/run/vmware/proxy-vpxa /vpxa <_type>vim.ProxyService.NamedPipeServiceSpec httpsWithRedirect /var/run/vmware/proxy-mob /mob <_type>vim.ProxyService.LocalServiceSpec httpAndHttps 8889 /wsman VMware, Inc. 229 ESX Server 3 Configuration Guide 4 Change the security settings as required. For example, you might want to modify  entries for services that use HTTPS to add the option of HTTP access.  e id is an ID number for the server ID XML tag. ID numbers must be unique  within the HTTP area.  _type is the name of the service you are moving, for example /sdk or /mob.  accessmode is the forms of communication the service permits. Acceptable  values include:  httpOnly – The service is accessible only over plain‐text HTTP  connections.  httpsOnly – The service is accessible only over HTTPS connections.   httpsWithRedirect – The service is accessible only over HTTPS  connections. Requests over HTTP will be redirected to the appropriate  HTTPS URL.  httpAndHttps – The service is accessible both over HTTP and HTTPS  connections.  port is the port number assigned to the service. You can assign a different port  number to the service.  namespace is the namespace for the server that provides this service. 5 Save your changes and close the file. 6 Enter the following command to restart the vmware-hostd process: service mgmt-vmware restart Example: Setting Up VI Web Access to Communicate Through an Insecure Port VI Web Access normally communicates with an ESX Server 3 host through a secure  port (HTTPS, 443). If you are in a fully trusted environment, you might decide that you  can almost permit an insecure port (for example, HTTP, 80). To do so, change the  accessMode attribute for the webserver in proxy.xml file, as described in “To change  security settings for a Web proxy service” on page 228. The result is as follows. The  accessMode is changed from httpsWithRedirect to httpAndHttps. <_type>vim.ProxyService.LocalServiceSpec httpAndHttps 8080 /ui 230 VMware, Inc. Chapter 11 Authentication and User Management Regenerating Certificates The ESX Server 3 host generates certificates when you first start the host after  installation. Thereafter, whenever you restart the vmware-hostd process, the  mgmt-vmware script searches for existing certificate files (rui.crt and rui.key) and,  if it cannot find them, generates new certificate files.  Under certain circumstances, you might need to force the ESX Server 3 host to generate  new certificates. You typically need to generate new certificates only if:  You change the host name.  You accidentally delete the certificates. To generate new certificates for the ESX Server 3 host 1 Change directories to /etc/vmware/ssl. 2 Create backups of any existing certificates by executing the following commands: mv rui.crt orig.rui.crt mv rui.key orig.rui.key NOTE   If you are regenerating certificates because you accidentally deleted your  certificates, you do not need to complete the backup step. 3 Enter the following command to restart the vmware-hostd process: service mgmt-vmware restart 4 Confirm that the ESX Server 3 host generated new certificates by executing the  following command comparing the time stamps of the new certificate files with  orig.rui.crt and orig.rui.key: ls -la Replacing Self-Signed Certificates with CA-Signed Certificates The ESX Server 3 host uses automatically generated self‐signed certificates that are  created as part of the installation process. These certificates make it possible to begin  using the server, but self‐signed certificates are vulnerable to a man‐in‐the‐middle  attack. To provide increased security, purchase a certificate from a trusted certificate  authority and use that certificate as a replacement for the automatically generated  certificate. VMware, Inc. 231 ESX Server 3 Configuration Guide To replace the existing certificate with a CA-signed certificate 1 Change directories to /etc/vmware/ssl. 2 Backup any existing certificates by renaming them using the following commands: mv rui.crt orig.rui.crt mv rui.key orig.rui.key 3 Copy the new certificate and key to the current location. Rename the certificate and  key to rui.crt and rui.key. Virtual Machine Delegates for NFS Storage To perform most activities on virtual machines, an ESX Server 3 needs access to virtual  machine files. For instance, to power on and off virtual machines, ESX Server 3 must be  able to create, manipulate, and delete files on the volume that is storing the virtual disk  files. To create, configure, or administer virtual machines on an NFS datastore, you can do so  using the delegate user. The delegate userʹs identity is used by the ESX Server 3i for all  I/O requests issued to the underlying file system. The delegate user is experimental and  is not officially supported. By default, the delegate user for the ESX Server 3 host is the user root. However,  having the user root as the delegate user might not work for all NFS datastores. NFS  administrators might export volumes with root squashing enabled. The root squash  feature maps the user root to a user with no significant privileges on the NFS server,  limiting the root userʹs abilities. This feature is commonly used to prevent  unauthorized access to files on an NFS volume. If the NFS volume was exported with  root squash enabled, the NFS server might refuse access to the ESX Server 3 host. To  ensure that you can create and manage virtual machines from your host, the NFS  administrator must turn off the root squash feature or add the ESX Server 3 host’s  physical network adapter to the list of trusted servers. If the NFS administrator is unwilling to take either of these actions, you can change the  delegate user to a different identity through experimental ESX Server 3 functionality.  This identity must match the owner of the directory on the NFS server, or the  ESX Server 3 host cannot perform file‐level operations. To set up a different identity for  the delegate user, acquire the following information: 232  User name of the directory owner  User ID (UID) of the directory owner  Group ID (GID) of the directory owner VMware, Inc. Chapter 11 Authentication and User Management Use this information to change the delegate user setting for the ESX Server 3 host so  that it matches the owner of the directory, enabling NFS datastore to recognize the  ESX Server 3 host correctly. The delegate user is configured globally, and the same  identity is used to access every volume. Setting up the delegate user on an ESX Server 3 host requires that you complete these  activities:  From the Users & Groups tab for a VI Client running directly on the ESX Server 3  host, either:  Edit the user named vimuser to add the correct UID and GID. vimuser is an  ESX Server 3 host user provided to you as a convenience for setting up  delegate users. By default, vimuser has a UID of 12 and a GID of 20.  Add a completely new user to the ESX Server 3 host with the delegate user  name, UID, and GID.  You must perform one of these steps regardless of whether you manage the host  through a direct connection or through the VirtualCenter Server. Also, make sure  that the delegate user (vimuser or a delegate user you create) is identical across all  ESX Server 3 hosts that use the NFS datastore. For information on adding users,  see “Working with the Users Table” on page 221.  Configure a virtual machine delegate as part of the security profile for the host, as  described in the procedure that follows. You configure the security profile through  VirtualCenter or through a VI Client running directly on the ESX Server 3 host. WARNING   Changing the delegate user for an ESX Server 3 host is experimental and,  currently, VMware does not support this implementation. Use of this function can result  in unexpected behavior. To change the virtual machine delegate 1 Log in to the VI Client through the ESX Server 3 host. 2 Select the server from the inventory panel.  The hardware configuration page for this server appears with the Summary tab  displayed. 3 Click Enter Maintenance Mode. 4 Click the Configuration tab and click Security Profile. 5 Click Virtual Machine Delegate > Edit to open the Virtual Machine Delegate  dialog box.  VMware, Inc. 233 ESX Server 3 Configuration Guide 6 Enter the user name for the delegate user. 7 Click OK. 8 Reboot the ESX Server 3 host.  After you reboot the host, the delegate user setting is visible in VirtualCenter and in the  VI Client running directly on the ESX Server 3 host. 234 VMware, Inc. 12 Service Console Security 12 This chapter makes basic security recommendations for using the service console and  explains some of the service console’s built‐in security features. The service console is a  management interface to ESX Server 3 and, as such, its security is critical. To protect the  service console against unauthorized intrusion and misuse, VMware imposes  constraints on several service console parameters, settings, and activities.  These constraints are designed to raise the security level for ESX Server 3. You can  loosen the constraints to meet your particular configuration needs, but if you do so,  make sure you are working in a trusted environment and have taken enough other  security measures to protect the network as a whole and the devices connected to the  ESX Server 3 host. This chapter discusses the following topics:  “General Security Recommendations” on page 236  “Service Console Firewall Configuration” on page 237  “Password Restrictions” on page 241  “Cipher Strength” on page 249  “setuid and setgid Applications” on page 250  “SSH Security” on page 253  “Security Patches and Security Vulnerability Scanning Software” on page 254 VMware, Inc. 235 ESX Server 3 Configuration Guide General Security Recommendations Consider the following recommendations when evaluating service console security  and administering the service console:  Limit user access.  To improve security, restrict user access to the service console and enforce access  security policies like setting up password restrictions—for example, character  length, password aging limits, and using a grub password for booting the host.  The service console has privileged access to certain parts of ESX Server 3.  Therefore, only trusted users should be provided login access. By default, root  access is limited by not allowing secure shell (SSH) login as the root user, and you  should strongly consider keeping this default. ESX Server 3 system administrators  should be required to log in as regular users and then use the sudo command to  perform specific tasks that require root privileges.  Also, try to run as few processes on the service console as possible. Ideally, strive  to run only the essential processes, services, and agents such as virus checkers,  virtual machine backups, and so forth.  Use VI Client to administer your ESX Server 3 hosts.  Whenever possible, use VI Client, VI Web Access, or a third‐party network  management tool to administer your ESX Server 3 hosts instead of working though  the command‐line interface as the root user. Using VI Client lets you limit the  accounts with access to the service console, safely delegate responsibilities, and set  up roles that prevent administrators and users from using capabilities they don’t  need.   Use only VMware sources to upgrade ESX Server 3 components that you run on the  service console.  The service console runs a variety of third‐party packages, such as the Tomcat Web  service, to support management interfaces or tasks that you need to perform.  VMware does not support upgrading these packages from anything other than a  VMware source. If you use a download or patch from another source, you might  compromise service console security or functions. Regularly check third‐party  vendor sites and the VMware knowledge base for security alerts. 236 VMware, Inc. Chapter 12 Service Console Security Logging On to the Service Console Although you perform most ESX Server 3 configuration activities through the  VI Client, you use the service console command‐line interface when you configure  certain security features. Using the command‐line interface requires that you log in  to the host. If you have direct access to the ESX Server 3 host, you can log in to the  physical console on that machine. To do so, press Alt+F2 to open the login page. For  remote connections, use SSH or another remote console connection to start a session on  the host. Whether you access the service console locally or through a remote connection such as  SSH, you must log in using a user name and password recognized by the ESX Server 3  host. For information on user names and passwords for ESX Server 3 hosts, see  “Working with Users and Groups on ESX Server 3 Hosts” on page 219. If you are logging onto the host to perform activities that require root privileges, you  should log in to the service console as a recognized user and acquire root privileges  through the su command or, preferably, the sudo command. The sudo command  enhances security because it grants root privileges only for select activities in contrast  to the su command, which grants root privileges for all activities. Using sudo also  provides superior accountability because all sudo activities are logged, whereas if you  use su, ESX Server 3 only logs the fact that the user switched to root by way of su. In addition to ESX‐specific commands, you can use the service console command‐line  interface to execute many Linux and Unix commands. For detailed usage notes on  service console commands, use the man  command to check for man  pages. Service Console Firewall Configuration ESX Server 3 includes a firewall between the service console and the network. To  ensure the integrity of the service console, VMware has reduced the number of firewall  ports that are open by default. At installation time, the service console firewall is  configured to block all incoming and outgoing traffic except for traffic on ports 902, 80,  443, and 22, which are used for basic communication with ESX Server 3. This setting  enforces a high level of security for the ESX Server 3 host.  NOTE   The firewall also allows Internet Control Message Protocol (ICMP) pings and  communication with DHCP and DNS (UDP only) clients. VMware, Inc. 237 ESX Server 3 Configuration Guide In trusted environments, you might decide that a lower security level is acceptable. If  so, you can set the firewall for either medium or low security:  Medium security – All incoming traffic is blocked except on the default ports (902,  433, 80, and 22) and any ports you specifically open. Outgoing traffic is not  blocked.  Low security – There are no blocks on either incoming or outgoing traffic. This  setting is equivalent to removing the firewall. Because the ports open by default are strictly limited, you might need to open  additional ports after installation. For a list of commonly used ports that you might  need to open, see “TCP and UDP Ports for Management Access” on page 183.  As you add the supported services and management agents required to operate  ESX Server 3 effectively, you open other ports in the service console firewall. You add  services and management agents through VirtualCenter as described in “Opening  Firewall Ports for Supported Services and Management Agents” on page 188. In addition to the ports you open for these services and agents, you might need to open  other ports when you configure certain devices, services, or agents such as storage  devices, backup agents, and management agents. For example, if you are using Veritas  NetBackup™ 4.5 as a backup agent, open ports 13720, 13724, 13782, and 13783, which  NetBackup uses for client‐media transactions, database backups, user backups or  restores, and so forth. To determine which ports to open, see vendor specifications for  the device, service, or agent. Changing the Service Console Security Level Altering the security level for the service console is a two‐part process: determining the  service console firewall security level and resetting the service console firewall setting.  To prevent unnecessary steps, always check the firewall setting before you change it. Each time you lower your security setting or open additional ports, you increase the  risk of intrusion in your network. Balance your access needs against how tightly you  want to control the security of the network. To determine the service console firewall security level 1 Log in to the service console and acquire root privileges. 2 Execute the following two commands to determine whether incoming and  outgoing traffic is blocked or allowed: esxcfg-firewall -q incoming esxcfg-firewall -q outgoing 238 VMware, Inc. Chapter 12 Service Console Security 3 Interpret the results as follows: Table 12-1. Service Console Security Levels Command Line Response Security Level Incoming ports blocked by default. High Outgoing ports blocked by default. Incoming ports blocked by default. Medium Outgoing ports not blocked by default. Incoming ports not blocked by default. Low Outgoing ports not blocked by default. To set the service console firewall security level 1 Log in to the service console and acquire root privileges. 2 Execute one of the following commands as applicable:  To set the service console firewall to medium security: esxcfg-firewall --allowOutgoing --blockIncoming  To set the virtual firewall to low security: esxcfg-firewall --allowIncoming --allowOutgoing CAUTION   Using the preceding command disables all firewall protection.  To return the service console firewall to high security: esxcfg-firewall --blockIncoming --blockOutgoing 3 Execute the following command to restart the vmware-hostd process: service mgmt-vmware restart Changing the service console firewall security level does not affect existing  connections. For example, if the firewall is set to low security and a backup is running  on a port you didn’t explicitly open, raising the firewall setting to high does not  terminate the backup. Rather, because the firewall is configured to pass packets for  previously established connections, the backup completes, releases the connection, and  no further connections are accepted for the port. VMware, Inc. 239 ESX Server 3 Configuration Guide Opening and Closing Ports in the Service Console Firewall You can open service console firewall ports when you install third‐party devices,  services, and agents. Before you open ports to support the item you are installing, see  vendor specifications to determine the necessary ports.  If you close a port, active sessions of the service associated with the port are not  automatically disconnected when you close the port. For example, if a backup is  executing and you close the port for the backup agent, the backup continues until it  completes and the agent releases the connection. Perform the following procedures only if you are opening or closing ports for services  or agents not specifically configurable through the VI Client. For information on  configuring additional ports in VirtualCenter, see “Opening Firewall Ports for  Supported Services and Management Agents” on page 188. CAUTION   VMware supports opening and closing firewall ports only through the  VI Client or the esxcfg-firewall command, as described below. Using any other  methods or scripts to open and close firewall ports can lead to unexpected behavior. To open a specific port in the service console firewall 1 Log in to the service console and acquire root privileges. 2 Execute the following command: esxcfg-firewall --openPort ,tcp|udp,in|out, where:  port_number is the vendor‐specified port number.  tcp|udp is the protocol. Select tcp for TCP traffic or udp for UDP traffic.  in|out is the traffic direction. Select in to open the port for inbound traffic or  out to open it for outbound traffic.  port_name is a descriptive name. The name does not need to be unique, but it  should be meaningful to help identify the service or agent using the port. For example:  esxcfg-firewall --openPort 6380,tcp,in,Navisphere 3 Execute the following command to restart the vmware-hostd process: service mgmt-vmware restart 240 VMware, Inc. Chapter 12 Service Console Security To close a specific port in the service console firewall 1 Log in to the service console and acquire root privileges. 2 Execute the following command: esxcfg-firewall -closePort ,tcp|udp,in|out, The port_name argument is optional for -closePort. For example:  esxcfg-firewall --closePort 6380,tcp,in 3 Execute the following command to restart the vmware-hostd process: service mgmt-vmware restart You can use the -closePort option to close only those ports that you opened with the  -openPort option. If you used a different method to open the port, use an equivalent  method to close it. For example, you can close the SSH port (22) only by disabling the  SSH Server incoming connection and SSH Client outgoing connection in the VI Client.  For information on opening and closing ports through the VI Client, see “Opening  Firewall Ports for Supported Services and Management Agents” on page 188. Password Restrictions The ease with which an attacker can log in to an ESX Server 3 host depends on their  ability to find a legitimate user name and password combination. A malicious user can  obtain a password in a number of ways. For example, an attacker can sniff insecure  network traffic, such as Telnet or FTP transmissions, for successful login attempts.  Another common method is to crack the password by running a password generator.  Passwords generators are useful for mounting various kinds of password attacks,  including brute force attacks, in which the generator tries every character combination  up to a certain password length, and dictionary attacks, in which the generator tries real  words and simple mutations of real words.  Implementing restrictions that govern the length, character sets, and duration of  passwords can make attacks that a password generator initiates far more difficult. The  longer and more complex the password, the harder it is for an attacker to discover. The  more often users have to change passwords, the more difficult it is to find a password  that works repeatably.  NOTE   Always consider the human factor when you decide how to implement  password restrictions. If you make passwords too hard to remember or enforce  frequent password changes, your users might be inclined to write down their  passwords, thus eliminating any benefit.  VMware, Inc. 241 ESX Server 3 Configuration Guide To help protect your password database from misuse, password shadowing is enabled  for ESX Server 3 so that password hashes are hidden from access. Also, ESX Server 3  uses MD5 password hashes, which provide stronger password security and let you set  minimum length requirements to more than eight characters. ESX Server 3 provides password controls on two levels to help you enforce password  policies for your users and limit the risk of password cracking:  Password aging – These controls govern how long a user password can be active  before the user is required to change it. They help ensure that passwords change  often enough so that if an attacker obtains a password through sniffing or social  engineering, they cannot keep accessing ESX Server 3 indefinitely.  Password complexity – These controls ensure that the users select passwords that  are hard for password generators to determine.  Password Aging To ensure that passwords don’t stay active for long periods, ESX Server 3 imposes the  following password aging restrictions for user logins by default:  Maximum days – (SEE UPDATE) The number of days that a user can keep a  password before it needs to be changed. The default setting for ESX Server 3 is 90  days. By default, the root account and other service accounts are exempt from the  90 day expiration.  Minimum days – The minimum number of days between password changes. The  default setting is 0, meaning that the users can change their passwords any time.  Warning time – The number of days in advance of password expiration that  ESX Server 3 observes when issuing a password change reminder. The default  setting is seven days. Warnings are only displayed when logging directly onto the  service console or when using SSH. You can tighten or loosen any of these settings by executing the esxcfg-auth  command options. To override the default password aging settings for an individual  user, use the chage command.  242 VMware, Inc. Chapter 12 Service Console Security To change default password aging restrictions for ESX Server 3 1 Log in to the service console and acquire root privileges. 2 Execute one or more of the following commands as applicable.  To change the maximum number of days a user can keep a password: esxcfg-auth --passmaxdays= where  is the maximum number of days before password  expiration.  To change the minimum number of days between password changes: esxcfg-auth --passmindays= where  is the minimum number of days between  password changes.  To change the warning time before a password change: esxcfg-auth --passwarnage= where  is the number of days of advanced warning a user  receives before a password change is due. To override default password aging restrictions for individual users or groups 1 Log in to the service console and acquire root privileges. 2 Execute one or more of the following commands as applicable:  To specify a new maximum days value: chage -M  To specify a new minimum days value: chage -m  To specify a new warning time value: chage -W To learn about other chage options, use the man chage command. VMware, Inc. 243 ESX Server 3 Configuration Guide Password Complexity By default, ESX Server 3 uses the pam_cracklib.so plug‐in to set the rules that users  must observe when creating passwords and to check password strength during the  creation process.  The pam_cracklib.so plug‐in lets you determine the basic standards that all  passwords must meet. By default, ESX Server 3 imposes no restrictions on the root  password. However, when nonroot users attempt to change their passwords, the  passwords they choose must meet the basic standards that pam_cracklib.so sets. In  addition, nonroot users can make only a certain number of password change attempts  before pam_cracklib.so begins issuing messages and eventually closes the password  change page. The ESX Server 3 defaults for pam_cracklib.so password standards  and retry restrictions are as follows:  Minimum length – The pam_cracklib.so minimum length parameter for  ESX Server 3 systems is set to nine. This means that the user must enter at least  eight characters if they use only one character class (lowercase, uppercase, digit, or  other).  The password length algorithm allows shorter passwords if the user enters a mix  of character classes. To calculate the actual character length a user needs to enter to  form a valid password for a given minimum length setting, apply the password  length algorithm as follows: M – CC = E where:  244  M is the minimum length parameter.  CC is the number of character classes the user includes in the password.  E is the number of characters the user must enter. VMware, Inc. Chapter 12 Service Console Security Table 12‐2 shows how the algorithm works, assuming the user enters at least one  lowercase character as part of the password. The pam_cracklib.so plug‐in does  not allow passwords of fewer than six characters. Thus, while the mathematically  accurate character requirement for a four character‐class password is five  characters, the effective requirement is six. Table 12-2. Password Complexity Algorithm Results Character Types in the Password Attempt # of Characters for a Valid Password Lowercase Characters 8 yes 7 yes Uppercase Characters Digits yes yes yes yes 6 yes yes yes yes yes yes 5  yes Other Characters yes yes yes yes yes yes yes Retries – The pam_cracklib.so retries parameter for ESX Server 3 systems is set  to three. If the user does not enter a strong enough password in three attempts,  pam_cracklib.so closes the password change dialog box. The user must open a  new password change session to try again. The pam_cracklib.so plug‐in checks all password change attempts to ensure that  passwords meet the following strength criteria:  The new password must not be a palindrome—a password where the characters  mirror each other around a central letter, as in radar or civic.  The new password must not be the reverse of the old password.  The new password must not be a rotation—a version of the old password in which  one or more characters have been rotated to the front or back of the password  string.  The new password must differ from the old password by more than a change of  case.  The new password must differ from the old password by more than a few  characters. VMware, Inc. 245 ESX Server 3 Configuration Guide  The new password must not have been used in the past. The pam_cracklib.so  plug‐in applies this criterion only if you have configured a password reuse rule. By default, ESX Server 3 does not enforce any password reuse rules, so ordinarily  the pam_cracklib.so plug‐in never rejects a password change attempt on these  grounds. However, you can configure a reuse rule to ensure that your users do not  alternate between a few passwords. If you configure a reuse rule, old passwords are stored in a file that the  pam_cracklib.so plug‐in references during each password change attempt. The  reuse rules determine the number of old passwords that ESX Server 3 retains.  When a user creates enough passwords to reach the value specified in the reuse  rule, old passwords are removed from the file in age order. To learn how to  configure a reuse rule, see “To configure a password reuse rule” on page 246.  The new password must be long enough and complex enough. You configure these  requirements by changing the pam_cracklib.so complexity parameters with the  esxcfg-auth command, which lets you set the number of retries, the minimum  password length, and a variety of character credits. Character credits let the user  enter shorter passwords if they include more character types in the password. To  learn how to configure password length and complexity, see “To change default  password complexity for the pam_cracklib.so plug‐in” on page 247. For more information on the pam_cracklib.so plug‐in, see your Linux  documentation.  NOTE   The pam_cracklib.so plug‐in used in Linux provides more parameters than  the parameters supported for ESX Server 3. You cannot specify these additional  parameters in esxcfg-auth. To configure a password reuse rule 1 Log in to the service console and acquire root privileges. 2 Change directories by entering cd /etc/pam.d/ at the command prompt. 3 Use a text editor to open the system-auth file. 4 Locate the line that starts with: password 5 sufficient /lib/security/$ISA/pam_unix.so Add the following parameters to the end of the line: remember=X where X is the number of old passwords to store for each user. Use a space as the  delimiter between remember=X and the preceding parameter. 246 VMware, Inc. Chapter 12 Service Console Security 6 Save your changes and close the file. 7 Change directories to /etc/security/ and issue the following command to make  a zero (0) length file with opasswd as the filename: touch opasswd 8 Enter the following commands: chmod 0600 opasswd chown root:root /etc/security/opasswd To change default password complexity for the pam_cracklib.so plug-in 1 Log in to the service console and acquire root privileges. 2 Enter the following command: esxcfg-auth --usecrack= where:  retries is the number of retries the user is allowed before ESX Server 3 locks  them out of password change mode.  minimum_length is the minimum number of characters a user must enter to  make the password acceptable. This number is the total length before any  length credits are applied.  One length credit is always applied so, in effect, the password length is one  character less than the minimum_length parameter you specify. Because the  pam_cracklib.so plug‐in does not accept passwords of fewer than six  characters, calculate the minimum_length parameter so that users cannot  drop the password length below six as a result of subtracting the length  credits. VMware, Inc.  (SEE UPDATE) lc_credit is the number by which the minimum_length  parameter is reduced if the user includes at least one lowercase character in  the password.  uc_credit is the number by which the minimum_length parameter is  reduced if the user includes at least one uppercase character.   d_credit is the number by which the minimum_length parameter is reduced  if the user includes at least one digit.   oc_credit is the number by which the minimum_length parameter is  reduced if the user includes at least one special character, such as an  underscore or dash.  247 ESX Server 3 Configuration Guide Enter character credit parameters as a positive number or as zero (0) if you do not want  the plug‐in to give the user credit for including this character class. Character credits  are additive. The more different types of characters the user enters, the fewer characters  are required to form a valid password. For example, you issue the following command: esxcfg-auth --usecrack=3 11 1 1 1 2 With this setting in effect, a user creating a password that contains lowercase characters  and one underscore needs eight characters to create a valid password. If the user  decides to include all types of characters (lowercase alphabetical, uppercase  alphabetical, numeric, and special), they would need only six characters. Changing the Password Plug-In The pam_cracklib.so plug‐in provides sufficient password strength enforcement for  most environments. However, if the pam_cracklib.so plug‐in is not stringent enough  for your needs, you can use the pam_passwdqc.so plug‐in instead. You change the  plug‐in through the esxcfg-auth command. The pam_passwdqc.so plug‐in tests for the same password characteristics as the  pam_cracklib.so plug‐in. However, it provides a greater number of options for  fine‐tuning password strength and performs password strength tests for all users,  including the root user. The pam_passwdqc.so plug‐in is also somewhat more difficult  to use than the pam_cracklib.so plug‐in. For more information on this plug‐in, see  your Linux documentation. NOTE   The pam_passwdqc.so plug‐in used in Linux provides more parameters than  the parameters supported for ESX Server 3. You cannot specify these additional  parameters in esxcfg-auth. To switch to the pam_passwdqc.so plug-in 1 Log in to the service console and acquire root privileges. 2 Enter the following command: esxcfg-auth --usepamqc= where: 248  N0 is the number of characters required for a password that uses characters  from only one character class.   N1 is the number of characters required for a password that uses characters  from two character classes. VMware, Inc. Chapter 12 Service Console Security  N2 is used for passphrases. ESX Server 3 requires three words for a  passphrase.   N3 is the number of characters required for a password that uses characters  from three character classes.  N4 is the number of characters required for a password that uses characters  from all four character classes.  match is the number of characters allowed in a string that is reused from the  old password. If the pam_passwdqc.so plug‐in finds a reused string of this  length or longer, it disqualifies the string from the strength test and uses only  the remaining characters.  Setting any of these options to -1 directs the pam_passwdqc.so plug‐in to ignore  the requirement. Setting any of these options to disabled directs the  pam_passwdqc.so plug‐in to disqualify passwords with the associated  characteristic. The values used must be in descending order except for -1 and  disabled. For example, you issue the following command: esxcfg-auth --usepamqc=disabled 18 -1 12 8 With this setting in effect, a user creating a password would never be able to set  passwords that contain only one character class. The user needs to use at least 18  characters for a password with a two‐character class, 12 characters for a  three‐character class password, and eight characters for four‐character class  passwords. Attempts to create passphrases are ignored. Cipher Strength Transmitting data over insecure connections presents a security risk because malicious  users might be able to scan data as it travels through the network. As a safeguard,  network components commonly encrypt the data so that it can’t be easily read. To  encrypt data, the sending component, such as a gateway or redirector, applies  algorithms, or ciphers, to alter the data before transmitting it. The receiving component  uses a key to decrypt the data, returning it to its original form.  Several different ciphers are currently in use, and the level of security that each  provides is different. One measure of a cipher’s ability to protect data is its cipher  strength—the number of bits in the encryption key. The larger the number, the more  secure the cipher. VMware, Inc. 249 ESX Server 3 Configuration Guide To ensure the protection of the data transmitted to and from external network  connections, ESX Server 3 uses one of the strongest block ciphers available—256‐bit  AES block encryption. ESX Server 3 also uses 1024‐bit RSA for key exchange. These  encryption algorithms are the default for the following connections:  VI Client connections to the VirtualCenter Server and to the ESX Server 3 host  through the service console.  VI Web Access connections to the ESX Server 3 host through the service console. NOTE   Because VI Web Access cipher usage is determined by the Web browser you  are using, this management tool might use other ciphers.  SDK connections to the VirtualCenter Server and to the ESX Server 3.  Service console connections to virtual machines through the VMkernel.  SSH connections to the ESX Server 3 host through the service console. For more  information, see “SSH Security” on page 253. setuid and setgid Applications setuid is a flag that allows an application to temporarily change the permissions of the  user running the application by setting the effective user ID to the program owner’s  user ID. setgid is a flag that allows an application to temporarily change the  permissions of the group running the application by setting the effective group ID to  the program owner’s group ID.  During ESX Server 3 installation, several applications that include the setuid and  setgid flags are installed by default. These applications are initiated by or through the  service console. Some of them provide facilities required for correct operation of the  ESX Server 3 host. Others are optional, but they can make maintaining and  troubleshooting the ESX Server 3 host and the network easier.  250 VMware, Inc. Chapter 12 Service Console Security Default setuid Applications Table 12‐3 lists the default setuid applications and indicates whether the application  is required or optional. Table 12-3. Default setuid Applications Application crontab Purpose and Path Required or Optional Lets individual users add cron jobs. Optional Path: /usr/bin/crontab  pam_timestamp_check Supports password authentication. Required Path: /sbin/pam_timestamp_check passwd Supports password authentication. Required Path: /usr/bin/passwd  ping Sends and listens for control packets on the  network interface. Useful for debugging  networks. Optional Path: /bin/ping  pwdb_chkpwd Supports password authentication. Required Path: /sbin/pwdb_chkpwd ssh-keysign Performs host‐based authentication for SSH. Path: /usr/libexec/openssh/ssh-keysign Required if you  use host‐based  authentication. Otherwise  optional. su Lets a general user become the root user by  changing users. Required Path: /bin/su  sudo Lets a general user act as the root user only for  specific operations. Optional Path: /usr/bin/sudo  unix_chkpwd Supports password authentication. Required Path: /sbin/unix_chkpwd  vmkload_app Performs tasks required to run virtual  machines. This application is installed in two  locations: one for standard use and one for  debugging.  Required in both  paths Path for standard use:  /usr/lib/vmware/bin/vmkload_app  Path for debugging:  /usr/lib/vmware/bin-debug/vmkload_app VMware, Inc. 251 ESX Server 3 Configuration Guide Table 12-3. Default setuid Applications (Continued) Application Purpose and Path vmware-authd Authenticates users for use of services specific  to VMware. Required or Optional Required Path: /usr/sbin/vmware-authd  vmware-vmx Performs tasks required to run virtual  machines. This application is installed in two  locations: one for standard use and one for  debugging.  Required in both  paths Path for standard use:  /usr/lib/vmware/bin/vmware-vmx  Path for debugging:  /usr/lib/vmware/bin-debug/vmware-vmk Disabling any of the required applications results in problems with ESX Server 3  authentication and virtual machine operation, but you can disable any optional  application. To disable an optional setuid application 1 Log in to the service console and acquire root privileges. 2 Execute the following command: chmod a-s Default setgid Applications Two applications that include the setgid flag are installed by default. Table 12‐4 lists  the default setgid applications and indicates whether the application is required or  optional. Table 12-4. Default setgid Applications Application Purpose and Path wall Alerts all terminals that an action is about to  occur. This application is called by shutdown  and other commands. Required or Optional Optional Path: /usr/bin/wall  lockfile Performs locking for the Dell OM management  agent. Path: /usr/bin/lockfile 252 Required for  Dell OM but  optional  otherwise VMware, Inc. Chapter 12 Service Console Security Disabling a required application results in problems with ESX Server 3 authentication  and virtual machine operation, but you can disable any optional application. To disable an optional setgid application 1 Log in to the service console and acquire root privileges. 2 Execute the following command: chmod a-g SSH Security SSH is a commonly used UNIX and Linux command shell that lets you remotely log in  to the service console and perform certain management and configuration tasks for  ESX Server 3. SSH is used for secure logins and data transfers because it offers stronger  protection than other command shells. In this ESX Server 3 release, the SSH  configuration is enhanced to provide a higher security level. Key features of this  enhancement include:  Version 1 SSH protocol disabled – VMware no longer supports Version 1 SSH  protocol and uses Version 2 protocol exclusively. Version 2 eliminates certain  security issues present in Version 1 and provides you with a safer communications  interface to the service console.   Improved cipher strength – SSH now supports only 256‐bit and 128‐bit AES  ciphers for your connections.  Limits on remote logins as root – You can no longer remotely log in as root.  Instead, you log in as an identifiable user and either use the sudo command to  execute specific operations that require root privileges or enter the su command to  become the root user.  NOTE   The sudo command provides security benefits in that it limits root activities  and helps you check for possible misuse of root privileges by generating an audit  trail of any root activities that the user performs.  These settings are designed to provide solid protection for the data you transmit to the  service console through SSH. If this configuration is too rigid for your needs, you can  lower security parameters. To change the default SSH configuration 1 Log in to the service console and acquire root privileges. 2 Change directories by entering cd /etc/ssh at the command prompt. VMware, Inc. 253 ESX Server 3 Configuration Guide 3 Use a text editor to perform any or all of following actions, as appropriate.  To allow remote root login, change the setting to yes in the following line in  the sshd_config file:  PermitRootLogin no  To revert to the default SSH protocol (Version 1 and 2), comment out the  following line in the sshd_config file:  Protocol 2  To revert to the 3DES cipher and other ciphers, comment out the following line  in the sshd_config file:  Ciphers aes256-cbc,aes128-cbc  To disable Secure FTP (SFTP) on SSH, comment out the following line in the  sshd_config file:  Subsystem ftp /usr/libexec/openssh/sftp-server 4 Save your changes and close the file. 5 Execute the following command to restart the SSHD service: service sshd restart Security Patches and Security Vulnerability Scanning Software If a fix for a particular LINUX‐supported software package that VMware provides as a  service console component becomes available—for example, a service, facility, or  protocol—VMware provides an RPM Package Manager (RPM) package that you use to  update the software package on ESX Server 3. Although these fixes might be available  from other sources, always use RPMs that VMware generates instead of using  third‐party RPMs. When providing patches for a software package, the VMware policy is to backport the  fix to a version of the software known to be stable. This approach reduces the chance of  introducing new problems and instability in the software. Because the patch is added  to an existing version of the software, the version number of the software stays the  same, but a patch number is added as a suffix. 254 VMware, Inc. Chapter 12 Service Console Security Certain security scanners such as Nessus check the version number but not the patch  suffix as they search for security holes. As a result, these scanners can falsely report that  software is down‐level and doesn’t include the most recent security patches even  though it does. This problem is common to the industry and not specific to VMware. NOTE   Some security scanners can handle this situation correctly, but they typically lag  by a version or more. For example, the version of Nessus released after a Red Hat patch  often doesn’t report these false positives. The following is an example of how this problem occurs: 1 You initially install ESX Server 3 with OpenSSL version 0.9.7a (where 0.9.7a is the  original version with no patches). 2 OpenSSL releases a patch that fixes a security hole in version 0.9.7. This version is  called 0.9.7x. 3 VMware backports the OpenSSL 0.9.7x fix to the original version, updates the  patch number, and creates an RPM. The OpenSSL version in the RPM is 0.9.7a‐1,  indicating that the original version (0.9.7a) now contains patch 1. 4 You install the RPM. 5 The security scanner fails to note the ‐1 suffix and erroneously reports that security  for OpenSSL isn’t up‐to‐date. If your scanner reports that security for a package is down‐level, perform the following  checks:  Look at the patch suffix to determine whether you need to get an update.  Read the VMware RPM documentation for information on the patch contents.  Use the following command to look for Common Vulnerabilities and Exposures  (CVE) number from the security alert in the RPM change log: rpm- q --changelog openssl | grep If the CVE number is there, the specified package addresses that vulnerability. VMware, Inc. 255 ESX Server 3 Configuration Guide 256 VMware, Inc. 13 Security Deployments and Recommendations 13 The chapter focuses on giving you a better idea of how to secure your ESX Server 3 in  particular environments by presenting a series of ESX Server 3 deployment scenarios  that you can consider as you plan some of the security features of your own  deployment. It also makes some basic security recommendations you can consider  when creating and configuring virtual machines. This chapter covers the following topics:  “Security Approaches for Common ESX Server 3 Deployments” on page 257  “Virtual Machine Recommendations” on page 263 Security Approaches for Common ESX Server 3 Deployments The complexity of ESX Server 3 deployments can vary significantly depending on the  size of your company, the way that data and resources need to be shared with the  outside world, whether there are multiple datacenters or just one, and so forth.  Inherent in the following deployments are policies for user access, resource sharing,  and security level. By comparing the deployments, you can get a sense of the issues you  face in planning security for your own ESX Server 3 deployment. Single Customer Deployment In this deployment, the ESX Server 3 hosts are owned and maintained within a single  corporation and single datacenter. No ESX Server 3 resources are shared with outside  users. One site administrator maintains the ESX Server 3 hosts, and these hosts run a  number of virtual machines. VMware, Inc. 257 ESX Server 3 Configuration Guide The deployment does not allow customer administrators, and the site administrator is  solely responsible for maintaining the various virtual machines. The corporation staffs  a set of system administrators who do not have accounts on the ESX Server 3 host and  cannot access any of the ESX Server 3 tools such as VirtualCenter or command line  shells for the host. These system administrators have access to virtual machines  through the virtual machine console so that they can load software and perform other  maintenance tasks inside the virtual machines. Table 13‐1 shows how you might handle sharing for the components you use and  configure for the ESX Server 3 host. Table 13-1. Sharing for Components in a Single Customer Deployment Function Configuration Comments Service console shares the  same physical network as  the virtual machines? No  Isolate the service console by configuring it on  its own physical network.  Service console shares the  same VLAN as the virtual  machines? No  Isolate the service console by configuring it on  its own VLAN. No virtual machine or other  system facility such as VMotion should use  this VLAN.  Virtual machines share the  same physical network? Yes Configure your virtual machines on the same  physical network. Network adapter sharing? Partial Isolate the service console by configuring it on  its own virtual switch and virtual network  adapter. No virtual machine or other system  facility should use this switch or adapter.  However, you can configure your virtual  machines on the same virtual switch and  network adapter. 258 VMFS sharing? Yes All .vmdk files should reside in the same  VMFS partition. Security level High Open ports for needed services like FTP on an  individual basis. See “Service Console  Firewall Configuration” on page 237 for  information on security levels. Virtual machine memory  overcommitment? Yes Configure the total memory for the virtual  machines as greater than the total physical  memory. VMware, Inc. Chapter 13 Security Deployments and Recommendations Table 13‐2 shows how you might set up user accounts for the ESX Server 3 host. Table 13-2. User Account Setup in a Single Customer Deployment User Category Total Number of Accounts Site administrators 1  Customer administrators 0  System administrators 0 Business users 0 Table 13‐3 shows the level of access for each user. Table 13-3. User Access in a Single Customer Deployment Access Level Site Administrator System Administrator Root access? Yes  No  Service console access through SSH? Yes  No  VirtualCenter and VI Web Access? Yes No  Virtual machine creation and modification? Yes No  Virtual machine access through the console? Yes Yes Multiple Customer Restricted Deployment In this deployment, the ESX Server 3 hosts are in the same datacenter and are used to  serve applications for multiple customers. The site administrator maintains the  ESX Server 3 hosts, and these hosts run a number of virtual machines dedicated to the  customers. Virtual machines that belong to the various customers can be on the same  ESX Server 3 host, but the site administrator restricts resource sharing to prevent rogue  interaction.  While there is only one site administrator, several customer administrators maintain  the virtual machines assigned to their customers. This deployment also includes  customer system administrators who do not have ESX Server 3 accounts but have  access to the virtual machines through the virtual machine console so that they can load  software and perform other maintenance tasks inside the virtual machines. VMware, Inc. 259 ESX Server 3 Configuration Guide Table 13‐4 shows how you might handle sharing for the components you use and  configure for the ESX Server 3 host. Table 13-4. Sharing for Components in a Multiple Customer Restricted Deployment Function Configuration Comments Service console shares the  same physical network as  the virtual machines? No  Isolate the service console by configuring it on  its own physical network.  Service console shares the  same VLAN as the virtual  machines? No  Isolate the service console by configuring it on  its own VLAN. No virtual machine or other  system facility such as VMotion should use this  VLAN.  Virtual machines share  the same physical  network? Partial  Put the virtual machines for each customer on a  different physical network. All physical  networks are independent of each other. Network adapter  sharing? Partial Isolate the service console by configuring it on  its own virtual switch and virtual network  adapter. No virtual machine or other system  facility should use this switch or adapter.  You configure virtual machines for one  customer so that they all share the same virtual  switch and network adapter. However, they do  not share the switch and adapter with any other  customers. 260 VMFS sharing? No Each customer has their own VMFS partition  and their virtual machine .vmdk files reside  exclusively on that partition. The partition can  span multiple LUNs. Security level High Open ports for services like FTP as needed. Virtual machine memory  overcommitment? Yes Configure the total memory for the virtual  machines as greater than the total physical  memory. VMware, Inc. Chapter 13 Security Deployments and Recommendations Table 13‐5 shows how you might set up user accounts for the ESX Server 3 host. Table 13-5. User Account Setup in a Multiple Customer Restricted Deployment User Category Total Number of Accounts Site administrators 1  Customer administrators 10  System administrators 0 Business users 0 Table 13‐6 shows the level of access for each user. Table 13-6. User Access in a Multiple Customer Restricted Deployment Access Level Site Administrator Customer Administrator System Administrator Root access? Yes  No  No  Service console access through SSH? Yes  Yes  No  VirtualCenter and VI Web Access? Yes Yes No  Virtual machine creation and  modification? Yes Yes No  Virtual machine access through the  console? Yes Yes Yes  Multiple Customer Open Deployment In this deployment, the ESX Server 3 hosts are in the same datacenter and are used to  serve applications for multiple customers. The site administrator maintains the  ESX Server 3 hosts, and these hosts run a number of virtual machines dedicated to the  customers. Virtual machines that belong to the various customers can be on the same  ESX Server 3 host, but there are fewer restrictions on resource sharing.  While there is only one site administrator, several customer administrators maintain  the virtual machines assigned to their customers. The deployment also includes  customer system administrators who do not have ESX Server 3 accounts but have  access to the virtual machines through the virtual machine console so that they can load  software and perform other maintenance tasks inside the virtual machines. Lastly, a  group of business users who do not have accounts can use virtual machines to run their  applications. VMware, Inc. 261 ESX Server 3 Configuration Guide Table 13‐7 shows how you might handle sharing for the components you use and  configure for the ESX Server 3 host. Table 13-7. Sharing for Components in a Multiple Customer Open Deployment Function Configuration Comments Service console shares the  same physical network as the  virtual machines? No  Isolate the service console by configuring it  on its own physical network.  Service console shares the  same VLAN as the virtual  machines? No  Isolate the service console by configuring it  on its own VLAN. No virtual machine or  other system facility such as VMotion  should use this VLAN.  Virtual machines share the  same physical network? Yes Configure your virtual machines on the  same physical network. Network adapter sharing? Partial Isolate the service console by configuring it  on its own virtual switch and virtual  network adapter. No virtual machine or  other system facility should use this switch  or adapter.  You configure all virtual machines on the  same virtual switch and network adapter. VMFS sharing? Yes Virtual machines can share VMFS partitions  and their virtual machine .vmdk files can  reside on shared partitions. Virtual  machines do not share .vmdk files. Security level High Open ports for services like FTP as needed. Virtual machine memory  overcommitment? Yes Configure the total memory for the virtual  machines as greater than the total physical  memory. Table 13‐8 shows how you might set up user accounts for the ESX Server 3 host. Table 13-8. User Account Setup in a Multiple Customer Open Deployment 262 User Category Total Number of Accounts Site administrators 1  Customer administrators 10  System administrators 0 Business users 0 VMware, Inc. Chapter 13 Security Deployments and Recommendations Table 13‐9 shows the level of access for each user. Table 13-9. User Access in a Multiple Customer Open Deployment Access Level Site Administrator Customer Administrator System Administrator Business User Root access? Yes  No  No  No  Service console access  through SSH? Yes  Yes  No  No  VirtualCenter and VI  Web Access? Yes Yes No  No  Virtual machine  creation and  modification? Yes Yes No  No  Virtual machine access  through the console? Yes Yes Yes  Yes  Virtual Machine Recommendations Consider the following safety precautions when evaluating virtual machine security  and administering virtual machines. Installing Antivirus Software Because each virtual machine hosts a standard operating system, you should consider  protecting it from viruses by installing antivirus software. Depending on how you are  using the virtual machine, you might also want to install a software firewall. NOTE   Software firewalls and antivirus software can be virtualization‐intensive. If you  are confident that your virtual machines are in a fully trusted environment, you can  balance the need for these two security measures against virtual machine performance. Disabling Copy and Paste Operations Between the Guest Operating System and Remote Console When VMware Tools runs on a virtual machine, you can copy and paste between the  guest operating system and remote console. As soon as the console window gains  focus, non‐privileged users and processes running in the virtual machine can access the  clipboard for the virtual machine console. If a user copies sensitive information to the  clipboard before using the console, the user—perhaps unknowingly—exposes  sensitive data to the virtual machine.  VMware, Inc. 263 ESX Server 3 Configuration Guide To prevent this problem, consider disabling copy and paste operations for the guest  operating system. To disable copy and paste operations between the guest operating system and remote console 1 Log on to the VI Client and select the virtual machine from the inventory panel.  The configuration page for this virtual machine appears with the Summary tab  displayed. 2 Click Edit Settings. 3 Click Options > Advanced > Configuration Parameters to open the Configuration  Parameters dialog box.  4 Click the Add button. 5 Type the following values in the Name field Value column. Table 13-10. Configuration Parameter Settings 264 Name Field Value Field isolation.tools.copy.disable true isolation.tools.paste.disable true isolation.tools.setGUIOptions.enable false VMware, Inc. Chapter 13 Security Deployments and Recommendations The result appears as follows. NOTE   These options override any settings made in the guest operating system’s  VMware Tools control panel. 6 Click OK to close the Configuration Parameters dialog box and then click OK  again to close the Virtual Machine Properties dialog box.  Removing Unnecessary Hardware Devices Nonprivileged users and processes within virtual machines can connect or disconnect  hardware devices, such as network adapters and CD‐ROM drives. Attackers can use  this capability to breach virtual machine security in several ways. For example, by  default, an attacker with access to a virtual machine can:  Connect a disconnected CD‐ROM drive and access sensitive information on the  media left in the drive.   Disconnect a network adapter to isolate the virtual machine from its network,  resulting in a denial of service.  VMware, Inc. 265 ESX Server 3 Configuration Guide As a general security precaution, use commands on the VI Client Configuration tab to  remove any unneeded or unused hardware devices. While this measure tightens  virtual machine security, it isn’t a good solution in situations where you might need to  bring a currently unused device back into service at a later time.  If you don’t want to permanently remove a device, you can prevent a virtual machine  user or process from connecting or disconnecting the device from within the guest  operating system.  To prevent a virtual machine user or process from disconnecting devices 1 Log on to the VI Client and select the virtual machine from the inventory panel.  The configuration page for this virtual machine appears with the Summary tab  displayed. 2 Click Edit Settings. The Virtual Machine Properties dialog box appears. 3 266 Click Options > General and make a record of the path displayed in the Virtual  Machine Configuration File field. VMware, Inc. Chapter 13 Security Deployments and Recommendations 4 Log on to the service console and acquire root privileges. 5 Change directories to access the virtual machine configuration file whose path you  recorded in Step 3.  Virtual machine configuration files are located in the  /vmfs/volumes/ directory, where  is the name of the  storage device on which the virtual machine files reside. For example, if the virtual  machine configuration file you obtained from the Virtual Machine Properties  dialog box is [vol1]vm-finance/vm-finance.vmx, you change directories as  follows: cd /vmfs/volumes/vol1/vm-finance/ 6 Use nano or another text editor to add the following line to the .vmx file. .allowGuestConnectionControl = "false" Where  is the name of the device you want to protect, for example,  ethernet1. NOTE   By default, Ethernet 0 is configured to disallow device disconnection. The  only reason you might need to change this is if a prior administrator set the  .allowGuestConnectionControl to true. 7 Save your changes and close the file. 8 Return to the VI Client and power off and power on the virtual machine. To do so,  right‐click the virtual machine in the inventory panel and click Power Off followed  by Power On. Limiting Guest Operating System Writes to Host Memory The guest operating system processes send informational messages to the ESX Server 3  host through VMware Tools. These messages, known as setinfo messages, typically  contain name‐value pairs that define virtual machine characteristics or identifiers that  the host stores—for example, ipaddress=10.17.87.224. If the amount of data the host stored as a result of these messages was unlimited, an  unrestricted data flow would provide an opportunity for an attacker to stage a DOS  attack by writing software that mimics VMware Tools and filling the host’s memory  with arbitrary configuration data, thus consuming space needed by the virtual  machines. VMware, Inc. 267 ESX Server 3 Configuration Guide To prevent this problem, the configuration file containing these name‐value pairs is  limited to a size of one megabyte. One megabyte should be sufficient for most cases, but  this value can be changed, as required. You might increase this value if large amounts  of custom information are being stored in the configuration file.  To modify the GuestInfo memory limit, set the tools.setInfo.sizeLimit attribute of  the.vmx file. The default limit is one megabyte, and this is applied, even if the  sizeLimit attribute does not exist. To modify guest operating system variable memory limit 1 Log on to the VI Client and select the virtual machine from the inventory panel.  The configuration page for this virtual machine appears with the Summary tab  displayed. 2 Click Edit Settings. 3 Click Options > Advanced > Configuration Parameters to open the Configuration  Parameters dialog box. 4 If the size limit attribute is not present, click Add Row and type the following:  Name field – tools.setInfo.sizeLimit  Value field –  If the size limit attribute exists, modify it to reflect the desired limits. 268 VMware, Inc. Chapter 13 Security Deployments and Recommendations A configuration that limits the GuestInfo size to 1048576 bytes (one MB) would  appear as follows: 5 Click OK to close the Configuration Parameters dialog box, and then click OK  again to close the Virtual Machine Properties dialog box. You may also elect to entirely prevent guests from writing any name‐value pairs to the  configuration file. This is appropriate when guest operating systems must be prevented  from modifying configuration settings. To prevent the guest operating system processes from sending configuration messages to the host 1 Log on to the VI Client and select the virtual machine from the inventory panel.  The configuration page for this virtual machine appears with the Summary tab  displayed. 2 Click Edit Settings. 3 Click Options > Advanced > Configuration Parameters to open the Configuration  Parameters dialog box.  VMware, Inc. 269 ESX Server 3 Configuration Guide 4 Click the Add button and type the following:  Name field – isolation.tools.setinfo.disable  Value field – true The result appears as follows. 5 Click OK to close the Configuration Parameters dialog box and then click OK  again to close the Virtual Machine Properties dialog box.  Configuring Logging Levels for the Guest Operating System Virtual machines can write troubleshooting information into a virtual machine log file  stored on the VMFS volume. Virtual machine users and processes can abuse logging  either on purpose or inadvertently so that large amounts of data flood the log file. Over  time, the log file can consume enough file system space to cause a denial of service.  To prevent this problem, consider modifying logging settings for virtual machine guest  operating systems. These settings can limit the total size and number of log files.  Normally a new log file is created each time a host is rebooted, so the file can grow to  be quite large, but you can ensure new log file creation happens more frequently by  limiting the maximum size of the log files. If you want to restrict the total size of logging  270 VMware, Inc. Chapter 13 Security Deployments and Recommendations data, VMware recommends saving 10 log files, each one limited to 100KB. These values  are small enough that the log files should not consume an undue amount of disk space  on the host, yet the extent of data stored is large enough that it should capture sufficient  information to debug most problems that might occur.  Each time an entry is written to the log, the size of the log is checked, and if it is over  the limit, the next entry is written to a new log. If there are already the maximum  number of log files, when a new one is created, the oldest one is deleted. A denial of  service attack that avoids these limits could be attempted by writing an enormous log  entry, but each log entry is limited in size to 4 KB, so no log files are ever more than 4  KB larger than the configured limit. To limit log file numbers and sizes 1 Log on to the VI Client and select the virtual machine from the inventory panel.  The configuration page for this virtual machine appears with the Summary tab  displayed. 2 Click Edit Settings. The Virtual Machine Properties dialog box appears. VMware, Inc. 271 ESX Server 3 Configuration Guide 3 Click Options > General and make a record of the path displayed in the Virtual  Machine Configuration File field. 4 Log on to the service console and acquire root privileges. 5 Change directories to access the virtual machine configuration file whose path you  recorded in Step 3.  Virtual machine configuration files are located in the  /vmfs/volumes/ directory, where  is the name of the  storage device on which the virtual machine files reside. For example, if the virtual  machine configuration file you obtained from the Virtual Machine Properties  dialog box is [vol1]vm-finance/vm-finance.vmx, you change directories as  follows: cd /vmfs/volumes/vol1/vm-finance/ 272 VMware, Inc. Chapter 13 Security Deployments and Recommendations 6 To limit the log size, use nano or another text editor to add or edit the following  line to the .vmx file. log.rotateSize= Where  is the maximum file size in bytes. For example, to limit  the size to around 100 KB, you could enter 100000. 7 To keep a limited number of log files, use nano or another text editor to add or edit  the following line to the .vmx file. log.keepOld= Where  is the number of files the server will keep.  For example, to keep 10 log files and then begin deleting the oldest ones as new  ones are created, you could enter 10. It is also possible to stop logging altogether. In making this decision, be aware that you  might not be able to gather adequate logs to allow troubleshooting. Further, VMware  does not offer technical support for virtual machine problems if logging has been  disabled. To disable logging for the guest operating system 1 Log on to the VI Client and select the virtual machine from the inventory panel.  The configuration page for this virtual machine appears with the Summary tab  displayed. 2 Click Edit Settings. 3 Click Options > Advanced > General.  VMware, Inc. 273 ESX Server 3 Configuration Guide 4 Deselect the Enable logging check box. The result appears as follows. 5 274 Click OK to close the Virtual Machine Properties dialog box.  VMware, Inc. Appendixes VMware, Inc. 275 ESX Server 3 Configuration Guide 276 VMware, Inc. A ESX Server 3 Technical Support Commands A This appendix lists the service console commands used to configure ESX Server 3. Most  of these commands are reserved for Technical Support use and are included for your  reference only. In a few cases, however, these commands provide the only means of  performing a configuration task for the ESX Server 3 host. Also, if you lose your  connection to the host, executing certain of these commands through the command‐line  interface may be your only recourse—for example, if networking becomes  nonfunctional and VI Client access is therefore unavailable.  NOTE   If you use the commands in this appendix, you must execute the service mgmt-vmware restart command to restart the vmware-hostd process and alert the  VI Client and other management tools that the configuration has changed. In general,  avoid executing the commands in this appendix if the host is currently under the  VI Client or VirtualCenter Server management.  The VI Client graphical user interface provides the preferred means of performing the  configuration tasks described in this appendix. You can use this appendix to learn  which VI Client commands to use in place of the service console commands. This  appendix provides a summary of the actions you take in VI Client but doesn’t give  complete instructions. For details on using commands and performing configuration  tasks through VI Client, see the online help. You can find additional information on a number of ESX Server 3 commands by  logging on to the service console and using the man   command to display man pages. VMware, Inc. 277 ESX Server 3 Configuration Guide Table A‐1 lists the Technical Support commands provided for ESX Server 3,  summarizes the purpose of each command, and provides a VI Client alternative. You  can perform most of the VI Client actions listed in the table only after you have selected  an ESX Server 3 host from the inventory panel and clicked the Configuration tab. These  actions are preliminary to any procedure discussed below unless otherwise stated. Table A-1. ESX Server 3 Technical Support Commands Service Console Command esxcfg-advcfg Command Purpose and VI Client Procedure Configures advanced options for ESX Server 3.  To configure advanced options in VI Client, click Advanced Settings.  When the Advanced Settings dialog box opens, use the list on the left  to select the device type or activity you want to work with and then  enter the appropriate settings. esxcfg-auth Configures authentication. You can use this command to switch  between the pam_cracklib.so and pam_passwdqc.so plugins for  password change rule enforcement. You also use this command to reset  options for these two plugins. For more information, see “Password  Complexity” on page 244. There is no means of configuring these functions in VI Client. esxcfg-boot Configures bootstrap settings. This command is used for the bootstrap  process and is intended for VMware Technical Support use only. You  should not issue this command unless instructed to do so by a VMware  Technical Support representative. There is no means of configuring these functions in VI Client. esxcfg-dumppart Configures a diagnostic partition or searches for existing diagnostic  partitions. When you install ESX Server 3, a diagnostic partition is created to store  debugging information in the event of a system fault. You don’t need to  create this partition manually unless you determine that there is no  diagnostic partition for the host. You can perform the following management activities for diagnostic  partitions in VI Client: 278  Determine whether there is a diagnostic partition — Click  Storage>Add and check the first page of the Add Storage Wizard  to see whether it includes the Diagnostic option. If Diagnostic is  not one of the options, ESX Server 3 already has a diagnostic  partition.   Configure a diagnostic partition — Click  Storage>Add>Diagnostic and step through the wizard.  VMware, Inc. Appendix A ESX Server 3 Technical Support Commands Table A-1. ESX Server 3 Technical Support Commands (Continued) Service Console Command esxcfg-firewall Command Purpose and VI Client Procedure Configures the service console firewall ports. To configure firewall ports for supported services and agents in  VI Client, you select the Internet services that will be allowed to access  the ESX Server 3 host. Click Security Profile>Firewall>Properties and  use the Firewall Properties dialog box to add services. For details on  adding supported services and configuring firewalls, see “Opening  Firewall Ports for Supported Services and Management Agents” on  page 188. You cannot configure unsupported services through the VI Client. For  these services, use the esxcfg-firewall command as described in  “Service Console Firewall Configuration” on page 237. esxcfg-info Prints information about the state of the service console, VMkernel,  various subsystems in the virtual network, and storage resource  hardware. VI Client doesn’t provide a method for printing this information, but  you can obtain much of it through different tabs and functions in the  user interface. For example, you can check the status of your virtual  machines by reviewing the information on the Virtual Machines tab. esxcfg-init Performs internal initialization routines. This command is used for the  bootstrap process you should not use it under any circumstances. Using  this command can cause problems for your ESX Server 3 host. There is no VI Client equivalent for this command. esxcfg-linuxnet Converts vswif to eth when booting ESX Server 3 into  service‐console‐only mode rather than into ESX mode. This command  is used for the bootstrap process and is intended for VMware Technical  Support use only. You should not issue this command unless instructed  to do so by a VMware Technical Support representative. There is no VI Client equivalent for this command. esxcfg-module Sets driver parameters and modifies which drivers are loaded during  startup. This command is used for the bootstrap process and is  intended for VMware Technical Support use only. You should not issue  this command unless instructed to do so by a VMware Technical  Support representative. There is no VI Client equivalent for this command. esxcfg-mpath Configures multipath settings for your Fibre Channel or iSCSI disks. To configure multipath settings for your storage in VI Client, click  Storage. Select a datastore or mapped LUN and click Properties. When  the Properties dialog box opens, select the desired extent if necessary.  Then, click Extent Device>Manage Paths and use the Manage Path  dialog box to configure the paths. VMware, Inc. 279 ESX Server 3 Configuration Guide Table A-1. ESX Server 3 Technical Support Commands (Continued) Service Console Command esxcfg-nas Command Purpose and VI Client Procedure Manages NAS mounts. You use this command to add, delete, list, and  change the attributes of NAS devices. To view NAS devices in VI Client, click Storage and scroll through the  storage list. You can also perform the following activities from the  Storage view:   Display the attributes of a NAS device – Click the device and  review the information under Details.   Add a NAS device – Click Add Storage.  Delete a NAS device – Click Remove.  Change the attributes of a NAS device – Click the device and click  Details>Properties. For complete instructions on how to create and configure NAS  datastores, see “Configuring ESX Server 3 to Access NFS Volumes” on  page 129. esxcfg-nics Prints a list of physical network adapters along with information on the  driver, PCI device, and link state of each NIC. You can also use this  command to control a physical network adapter’s speed and  duplexing. To view information on the physical network adapters for the host in  VI Client, click Network Adapters.  To change the speed and duplexing for a physical network adapter in  the VI Client, click Networking>Properties for any of the virtual  switches associated with the physical network adapter. In the  Properties dialog box, click Network Adapters>Edit and select the  speed and duplex combination. For complete instructions on how to  change the speed and duplexing, see “To configure the uplink network  adapter by changing its speed” on page 43. esxcfg-resgrp Restores resource group settings and lets you perform basic resource  group management.  Select a resource pool from the inventory panel and click Edit Settings  on the Summary tab to change the resource group settings. esxcfg-route Sets or retrieves the default VMkernel gateway route and adds,  removes, or lists static routes. To view the default VMkernel gateway route in VI Client, click DNS  and Routing. To change the default routing, click Properties and  update the information in both tabs of the DNS and Routing  Configuration dialog box. 280 VMware, Inc. Appendix A ESX Server 3 Technical Support Commands Table A-1. ESX Server 3 Technical Support Commands (Continued) Service Console Command esxcfg-swiscsi Command Purpose and VI Client Procedure Configures your software iSCSI software adapter. To configure your software iSCSI system in VI Client, click Storage  Adapters, select the iSCSI adapter you want to configure, and click  Properties. Use the iSCSI Initiator Properties dialog box to configure  the adapter. For complete instructions on how to create and configure iSCSI  datastores, see “iSCSI Storage” on page 110. esxcfg-upgrade Upgrades ESX Server from ESX Server 2.x to ESX Server 3. This  command is not for general use. You complete the following three tasks when upgrading from 2.x to 3.x.  Some of these can be performed in VI Client:  Upgrade the host — You upgrade the binaries, converting from  ESX Server 2.x to ESX Server 3. You cannot perform this step from  VI Client. For information on performing this upgrade, see the  Installation and Upgrade Guide.  Upgrade the file system — To upgrade VMFS‐2 to VMFS‐3,  suspend or power off your virtual machines and then click  Inventory>Host>Enter Maintenance Mode. Click Storage, select a  storage device, and click Upgrade to VMFS‐3. You must perform  this step for each storage device you want to upgrade.  Upgrade the virtual machines — To upgrade a virtual machine  from VMS‐2 to VMS‐3, right‐click the virtual machine in the  inventory panel and choose Upgrade Virtual Machine.  esxcfg-vmhbadevs Prints a map of VMkernel storage devices to service console devices.  There is no VI Client equivalent for this command. esxcfg-vmknic Creates and updates VMkernel TCP/IP settings for VMotion, NAS, and  iSCSI. To set up VMotion, NFS, or iSCSI network connections in VI Client,  click Networking>Add Networking. Select VMkernel and step  through the Add Network Wizard. Define the IP address subnet mask  and VMkernel default gateway in the Connection Settings step.  To review your settings, click the blue icon to the left of the VMotion,  iSCSI, or NFS port. To edit any of these settings, click Properties for the  switch. Select the port from the list on the switch Properties dialog box  and click Edit to open the port Properties dialog box and change the  settings for the port. For complete instructions on how to create and update VMotion, NFS,  or iSCSI network connections, see “VMkernel Networking  Configuration” on page 30. VMware, Inc. 281 ESX Server 3 Configuration Guide Table A-1. ESX Server 3 Technical Support Commands (Continued) Service Console Command esxcfg-vswif Command Purpose and VI Client Procedure Creates and updates service console network settings. This command is  used if you cannot manage the ESX Server 3 host through the VI Client  because of network configuration issues. For more information, see  “Troubleshooting Service Console Networking” on page 81. To set up connections for the service console in VI Client, click  Networking>Add Networking. Select Service Console and step  through the Add Network Wizard. Define the IP address subnet mask  and the service console default gateway in the Connection Settings  step.  To review your settings, click the blue icon to the left of the service  console port. To edit any of these settings, click Properties for the  switch. Select the service console port from the list on the switch  Properties dialog box. Click Edit to open the port Properties dialog box  and change the settings for the port. For complete instructions on how to create and update the service  console connection, see “Service Console Configuration” on page 34. esxcfg-vswitch Creates and updates virtual machine network settings. To set up connections for a virtual machine in VI Client, click  Networking>Add Networking. Select Virtual Machine and step  through the Add Network Wizard.  To review your settings, click the speech bubble icon to the left of the  virtual machine port group. To edit any of these settings, click  Properties for the switch. Select the virtual machine port from the list  on the switch Properties dialog box, then click Edit to open the port  Properties dialog box and change the settings for the port. For complete instructions on how to create and update virtual  machines, see “Virtual Network Configuration for Virtual Machines”  on page 27. Other Commands To support certain internal operations, ESX Server 3 installations include a subset of  standard Linux configuration commands, for example, network and storage  configuration commands. Using these commands to perform configuration tasks can  result in serious configuration conflicts and render some ESX Server 3 functions  unusable. Always work through the VI Client when configuring ESX Server 3 unless  otherwise instructed in VMware Infrastructure documentation or by VMware  Technical Support. 282 VMware, Inc. B Using vmkfstools B You use the vmkfstools utility to create and manipulate virtual disks, file systems,  logical volumes, and physical storage devices on the VMware ESX Server hosts. Using  vmkfstools, you can create and manage virtual machine file system (VMFS) on a  physical partition of a disk. You can also use the command to manipulate files, such as  virtual disk files, stored on VMFS‐2, VMFS‐3, and NFS. You can perform most vmkfstools operations using the VI Client. For information on  using the VI Client to work with storage, see “Configuring Storage” on page 103.  This appendix covers the following sections:  “vmkfstools Command Syntax” on page 283  “vmkfstools Options” on page 284 vmkfstools Command Syntax Generally, you don’t need to log in as the root user to run the vmkfstools commands.  However, some commands, such as the file system commands, might require the root  user login. Use the following arguments with the vmkfstools command:   are one or more command line options and associated arguments you  use to specify the activity for vmkfstools to perform — for example, choosing the  disk format when creating a new virtual disk.  After entering the option, specify a file or VMFS file system on which to perform  the operation by entering a relative or absolute file path name in the /vmfs  hierarchy. VMware, Inc. 283 ESX Server 3 Configuration Guide   specifies disk partitions. This argument uses a vmhbaA:T:L:P  format, where A, T, L, and P are integers representing adapter, target, LUN, and  partition number respectively. The partition digit must be greater than zero (0) and  should correspond to a valid VMFS partition of type fb.   For example, vmhba0:2:3:1 refers to the first partition on LUN 3, target 2, HBA 0.   specifies devices or logical volumes. This argument uses a path name in  the ESX Server 3 device file system. The path name begins with /vmfs/devices,  which is the mount point of the device file system.  Use the following formats when you specify different types of devices:   /vmfs/devices/disks for local or SAN‐based disks.  /vmfs/devices/lvm for ESX Server 3 logical volumes.  /vmfs/devices/generic for generic SCSI devices, such as tape drives.  specifies a VMFS file system or file. This argument is an absolute or relative  path that names a directory symbolic link, a raw device mapping, or a file under  /vmfs.   To specify a VMFS file system, use this format: /vmfs/volumes/ or /vmfs/volumes/   To specify a VMFS file, use this format: /vmfs/volumes//[dir]/myDisk.vmdk You do not need to enter the entire path if the current working directory is the  parent directory of myDisk.vmdk. For example, /vmfs/volumes/datastore1/rh9.vmdk vmkfstools Options This section includes a list of all options used with the vmkfstools command. Some of  the tasks in this section include options suggested for advanced users only.  The long and short (single letter) forms of options are equivalent. For example, the  following commands are identical: vmkfstools --createfs vmfs3 --blocksize 2m vmhba1:3:0:1 vmkfstools -C vmfs3 -b 2m vmhba1:3:0:1 284 VMware, Inc. Appendix B Using vmkfstools -v Suboption The -v suboption indicates the verbosity level of the command output. The format for  this suboption is as follows: -v --verbose You specify the  value as an integer from 1 through 10.  You can specify the -v suboption with any vmkfstools option. If the output of the  option isn’t suitable for use with the -v suboption, vmkfstools ignores -v.  NOTE   Because you can include the -v suboption in any vmkfstools command line,  -v is not included as a suboption in the option descriptions. File System Options File system options allow you to create a VMFS file system. These options do not apply  to NFS. You can perform many of these tasks through the VI Client.  Creating a VMFS File System -C --createfs vmfs3 -b --blocksize kK|mM -S --setfsname This option creates a VMFS‐3 file system on the specified SCSI partition, such as  vmhba1:0:0:1. The partition becomes the file systemʹs head partition. VMFS‐2 file systems are read‐only on any ESX Server 3 host. You cannot create or  modify VMFS‐2 file systems but you can read files stored on VMFS‐2 file systems.  VMFS‐3 file systems are not accessible from ESX 2.x hosts. CAUTION   You can have only one VMFS volume for a LUN. You can specify the following suboptions with the -C option:  -b --blocksize – Define the block size for the VMFS‐3 file system. The default  block size is 1MB. The  value you specify must be a multiple of  128kb, with a minimum value of 128kb. When you enter a size, indicate the unit  type by adding a suffix of m or M. The unit type is not case sensitive —  vmkfstools interprets m or M to mean megabytes and k or K to mean kilobytes.  VMware, Inc. 285 ESX Server 3 Configuration Guide  -S --setfsname – Define the volume label of a VMFS volume for the VMFS‐3 file  system you are creating. Use this suboption only in conjunction with the -C option.  The label you specify can be up to 128 characters long and cannot contain any  leading or trailing blank spaces. After you define a volume label, you can use it whenever you specify the VMFS  volume for the vmkfstools command. The volume label appears in listings  generated for the Linux ls -l command and as a symbolic link to the VMFS  volume under the /vmfs/volumes directory. To change the VMFS volume label, use the Linux ln -sf command. Use the  following as an example: ln -sf /vmfs/volumes/ /vmfs/volumes/  is the new volume label to use for the  VMFS. Example for Creating a VMFS File System vmkfstools -C vmfs3 -b 1m -S my_vmfs /vmfs/devices/disks/vmhba1:3:0:1 This example illustrates creating a new VMFS‐3 file system named my_vmfs on the first  partition of target 3, LUN 0 of vmhba adapter 1. The file block size is 1MB. Extending an Existing VMFS-3 Volume -Z --extendfs This option adds another extent to a previously created VMFS volume  . You must specify the full path name, for example  /vmfs/devices/disks/vmhba0:1:2:1, not just the short name vmhba0:1:2:1. Each  time you use this option, you extend a VMFS‐3 volume with a new extent so that the  volume spans multiple partitions. At most, a logical VMFS‐3 volume can have 32  physical extents.  CAUTION   When you run this option, you lose all data that previously existed on the  SCSI device you specified in . Example for Extending a VMFS-3 Volume vmkfstools -Z /vmfs/devices/disks/vmhba0:1:2:1 /vmfs/devices/disks/vmhba1:3:0:1 This example extends the logical file system by allowing it to span to a new partition.  The extended file system spans two partitions—vmhba1:3:0:1 and vmhba0:1:2:1. In  this example, vmhba1:3:0:1 is the name of the head partition. 286 VMware, Inc. Appendix B Using vmkfstools Listing Attributes of a VMFS Volume -P --queryfs -h --human-readable When you use this option on any file or directory that resides on a VMFS volume, the  option lists the attributes of the specified volume. The listed attributes include the  VMFS version number (VMFS‐2 or VMFS‐3), the number of extents comprising the  specified VMFS volume, the volume label if any, the UUID, and a listing of the device  names where each extent resides. NOTE   If any device backing VMFS file system goes offline, the number of extents and  available space change accordingly.  You can specify the -h suboption with the -P option. If you do so, vmkfstools lists the  capacity of the volume in a more readable form, for example, 5k, 12.1M, or 2.1G. Upgrading a VMFS-2 to VMFS-3 You can upgrade a VMFS‐2 file system to VMFS‐3.  CAUTION   The VMFS‐2 to VMFS‐3 conversion is a one‐way process. After you have  converted a VMFS‐2 volume to VMFS‐3, you cannot revert it back to a VMFS‐2 volume. You can upgrade a VMFS‐2 file system only if its file block size does not exceed 8 MB. When upgrading the file system, use the following options:  -T --tovmfs3 -x --upgradetype [zeroedthick|eagerzeroedthick|thin]  This option converts a VMFS‐2 file system VMFS‐3 preserving all files on the file  system. Before conversion, unload the vmfs2 and vmfs3 drivers and load the  auxiliary file system driver, fsaux, with a module option  fsauxFunction=upgrade. You must specify the upgrade type using the -x --upgradetype suboption as one  of the following: VMware, Inc.  -x zeroedthick (default) – Retains the properties of VMFS‐2 thick files. With  the zeroedthick file format, disk space is allocated to the files for future use  and the unused data blocks are not zeroed out.  -x eagerzeroedthick – Zeroes out unused data blocks in thick files during  conversion. If you use this suboption, the upgrade process might take much  longer than with the other options. 287 ESX Server 3 Configuration Guide  -x thin – Converts the VMFS‐2 thick files into thin‐provisioned VMFS‐3 files.  As opposed to thick file format, the thin‐provisioned format doesnʹt allow  files to have extra space allocated for their future use, but instead provides the  space on demand. During this conversion, unused blocks of the thick files are  discarded.  During conversion, the ESX Server 3 file‐locking mechanism ensures that no other  local process accesses the VMFS volume that is being converted, although you  need to make sure that no remote ESX Server host is accessing this volume. The  conversion might take several minutes and returns to the command prompt when  complete.  After conversion, unload the fsaux driver and load vmfs3 and vmfs2 drivers to  resume normal operations.  -u --upgradefinish  This option completes the upgrade.  Virtual Disk Options Virtual disk options allow you to set up, migrate, and manage virtual disks stored in  VMFS‐2, VMFS‐3, and NFS file systems. You can also perform most of these tasks  through the VI Client. Supported Disk Formats When you create or clone a virtual disk, you can use the -d --diskformat suboption  to specify the format for the disk. Choose from the following formats: 288  zeroedthick (default) – Space required for the virtual disk is allocated during  creation. Any data remaining on the physical device is not erased during creation,  but is zeroed out on demand at a later time on first write from the virtual machine.  The virtual machine does not read stale data from disk.  eagerzeroedthick – Space required for the virtual disk is allocated at creation  time. In contrast to zeroedthick format, the data remaining on the physical  device is zeroed out during creation. It might take much longer to create disks in  this format than to create other types of disks.  thick – Space required for the virtual disk is allocated during creation. This type  of formatting doesn’t zero out any old data that might be present on this allocated  space. A non‐root user is not allowed to create this format.  VMware, Inc. Appendix B Using vmkfstools  thin – Thin‐provisioned virtual disk. Unlike with the thick format, space  required for the virtual disk is not allocated during creation, but is supplied,  zeroed out, on demand at a later time.  rdm – Virtual compatibility mode raw disk mapping.  rdmp – Physical compatibility mode (pass‐through) raw disk mapping.  raw – Raw device.  2gbsparse – A sparse disk with 2GB maximum extent size. You can use disks in  this format with other VMware products, however, you cannot power on sparse  disk on an ESX Server host unless you first reimport the disk with vmkfstools in  a compatible format, such as thick or thin.  monosparse – A monolithic sparse disk. You can use disks in this format with  other VMware products.  monoflat – A monolithic flat disk. You can use disks in this format with other  VMware products. NOTE   The only disk formats you can use for NFS are thin, thick, zerodthick and  2gbsparse.  Thick, zeroedthick and thin usually mean the same because the NFS server and not  the ESX Server host decides the allocation policy. The default allocation policy on most  NFS servers is thin. Creating a Virtual Disk -c --createvirtualdisk [kK|mM|gG] -a --adaptertype [buslogic|lsilogic] -d --diskformat [thin|zeroedthick|eagerzeroedthick] This option creates a virtual disk at the specified path on a VMFS volume. Specify the  size of the virtual disk. When you enter the value for , you can indicate the unit  type by adding a suffix of k (kilobytes), m (megabytes), or g (gigabytes). The unit type  is not case sensitive—vmkfstools interprets either k or K to mean kilobytes. If you  don’t specify a unit type, vmkfstools defaults to bytes. You can specify the following suboptions with the -c option.   -a specifies the device driver that is used to communicate with the virtual disks.  You can choose between BusLogic and LSI Logic SCSI drivers.   -d specifies disk formats. For detailed description of the disk formats, see  “Supported Disk Formats” on page 288. VMware, Inc. 289 ESX Server 3 Configuration Guide Example for Creating a Virtual Disk vmkfstools -c 2048m /vmfs/volumes/myVMFS/rh6.2.vmdk This example illustrates creating a two‐gigabyte virtual disk file named rh6.2.vmdk on  the VMFS file system named myVMFS. This file represents an empty virtual disk that  virtual machines can access. Initializing a Virtual Disk -w --writezeros This option cleans the virtual disk by writing zeros over all its data. Depending on the  size of your virtual disk and the I/O bandwidth to the device hosting the virtual disk,  completing this command might take a long time. CAUTION   When you use this command, you lose any existing data on the virtual disk.  Inflating a Thin Virtual Disk -j --inflatedisk This option converts a thin virtual disk to eagerzeroedthick, preserving all existing  data. The option allocates and zeroes out any blocks that are not already allocated. See “Supported Disk Formats” on page 288. Deleting a Virtual Disk -U --deletevirtualdisk This option deletes files associated with the virtual disk listed at the specified path on  the VMFS volume.  Renaming a Virtual Disk -E --renamevirtualdisk This option renames a file associated with the virtual disk listed in the path  specification portion of the command line. You must specify the original file name or  file path  and the new file name or file path . Cloning a Virtual or Raw Disk -i --importfile -d --diskformat [rdm:|rdmp:| raw:|thin|2gbsparse|monosparse|monoflat] 290 VMware, Inc. Appendix B Using vmkfstools This option creates a copy of a virtual disk or raw disk you specify.  You can use the -d suboption for the -i option. This suboption specifies the disk format  for the copy you create. See “Supported Disk Formats” on page 288. A non‐root user is  not allowed to clone a virtual disk or a raw disk.  NOTE   To clone the ESX Server 3 Redo logs while preserving their hierarchy, use the cp  command. Example for Cloning a Virtual Disk vmkfstools -i /vmfs/volumes/templates/gold-master.vmdk /vmfs/volumes/myVMFS/myOS.vmdk This example illustrates cloning the contents of a master virtual disk from the  templates repository to a virtual disk file named myOS.vmdk on the myVMFS file  system. You can configure a virtual machine to use this virtual disk by adding lines to  the virtual machine configuration file, as in the following example: scsi0:0.present = TRUE scsi0:0.fileName = /vmfs/volumes/myVMFS/myOS.vmdk Migrating VMware Workstation and VMware GSX Server Virtual Machines You cannot use a VI Client to migrate virtual machines created with VMware  Workstation or VMware GSX Server into your ESX Server 3 system. However, you can  use the vmkfstools -i command to import the virtual disk into your ESX Server 3  system and then attach this disk to a new virtual machine you create in ESX Server 3.  You must import the virtual disk first because you cannot power on disks exported in  2gbsparse format on an ESX Server host.  To migrate VMware Workstation and GSX Server virtual machines 1 Import a Workstation or GSX Server disk into your /vmfs/volumes/myVMFS/  directory or any subdirectory. 2 In the VI Client, create a new virtual machine using the Custom configuration  option. 3 When you configure a disk, select Use an existing virtual disk and attach the  Workstation or GSX Server disk you imported. VMware, Inc. 291 ESX Server 3 Configuration Guide Extending a Virtual Disk -X --extendvirtualdisk [kK|mM|gG] This option extends the size of a disk allocated to a virtual machine after the virtual  machine has been created. You must power off the virtual machine that uses this disk  file before you enter this command. You might have to update the file system on the  disk so the guest operating system can recognize and use the new size of the disk and  take advantage of the extra space. You specify the newSize parameter in kilobytes, megabytes, or gigabytes by adding a  k (kilobytes), m (megabytes), or g (gigabytes) suffix. The unit type is not case  sensitive—vmkfstools interprets either k or K to mean kilobytes. If you don’t specify a  unit type, vmkfstools defaults to kilobytes. The newSize parameter defines the entire new size, not just the increment you add to  the disk.  For example, to extend a 4g virtual disk by 1g, enter: vmkfstools -X 5g .dsk NOTE   Do not extend the base disk of a virtual machine that has snapshots associated  with it. If you do, you can no longer commit the snapshot or revert the base disk to its  original size. Migrating a VMFS-2 Virtual Disk to VMFS-3 -M --migratevirtualdisk This option converts the specified virtual disk file from ESX Server 2 format to  ESX Server 3 format.  Creating a Virtual Compatibility Mode Raw Device Mapping -r --createrdm This option creates a Raw Device Mapping (RDM) file on a VMFS‐3 volume and maps  a raw disk to this file. After this mapping is established, you can access the raw disk as  you would a normal VMFS virtual disk. The file length of the mapping is the same as  the size of the raw disk it points to.  When specifying the  parameter, enter 0 for the partition to indicate that the  entire raw disk is used. Use the following format: /vmfs/devices/disks/vmhbaA:T:L:0 See “vmkfstools Command Syntax” on page 283 for more information.  292 VMware, Inc. Appendix B Using vmkfstools For more details on configuring and using RDMs, see “Raw Device Mapping” on  page 145. NOTE   All VMFS‐3 file‐locking mechanisms apply to RDMs. Example for Creating a Virtual Compatibility Mode RDM vmkfstools -r /vmfs/devices/disks/vmhba1:3:0:0 my_rdm.vmdk Creates an RDM file named my_rdm.vmdk and maps the vmhba1:3:0:0 raw disk to  that file. You can configure a virtual machine to use the my_rdm.vmdk mapping file by  adding the following lines to the virtual machine configuration file: scsi0:0.present = TRUE scsi0:0.fileName = /vmfs/volumes/myVMFS/my_rdm.vmdk Creating a Physical Compatibility Mode Raw Device Mapping -z --createrdmpassthru This option lets you map a pass‐through raw device to a file on a VMFS volume. This  mapping lets a virtual machine bypass ESX Server 3 SCSI command filtering when  accessing its virtual disk.This type of mapping is useful when the virtual machine  needs to send proprietary SCSI commands, for example, when SAN‐aware software  runs on the virtual machine.  After you establish this type of mapping, you can use it to access the raw disk just as  you would any other VMFS virtual disk.  When specifying the  parameter, enter 0 for the partition indicating that the  entire raw device is used. Use the following format: /vmfs/devices/disks/vmhbaA:T:L:0 See “vmkfstools Command Syntax” on page 283. Listing Attributes of an RDM -q --queryrdm This option lets you list the attributes of a raw disk mapping.  This option prints the vmhba name of the raw disk RDM. The option also prints other  identification information, like the disk ID, for the raw disk.  VMware, Inc. 293 ESX Server 3 Configuration Guide Displaying Virtual Disk Geometry -g --geometry This option gets information about the geometry of a virtual disk. The output is in the form: Geometry information C/H/S, where C represents the  number of cylinders, H represents the number of heads, and S represents the number of  sectors. NOTE   When you import VMware Workstation virtual disks to an ESX Server 3 host,  you might see a disk geometry mismatch error message. A disk geometry mismatch  might also be the cause of problems loading a guest operating system or running a  newly‐created virtual machine. Managing SCSI Reservations of LUNs The -L option allows you to perform administrative task for physical storage devices.  You can perform most of these tasks through the VI Client. -L --lock [reserve|release|lunreset|targetreset|busreset] This option lets you reserve a SCSI LUN for exclusive use by an ESX Server 3 host,  release a reservation so that other hosts can access the LUN, and reset a reservation,  forcing all reservations from the target to be released. CAUTION   Using the -L option can interrupt the operations of other servers on a SAN.  Use the -L option only when troubleshooting clustering setups.  Unless specifically advised by VMware, never use this option on a LUN hosting a VMFS  volume. You can specify the -L option in several ways: 294  -L reserve – Reserves the specified LUN. After the reservation, only the server  that reserved that LUN can access it. If other servers attempt to access that LUN, a  reservation error results.   -L release – Releases the reservation on the specified LUN. Other servers can  access the LUN again.  -L lunreset – Resets the specified LUN by clearing any reservation on the LUN  and making the LUN available to all servers again. The reset does not affect any of  the other LUNs on the device. If another LUN on the device is reserved, it remains  reserved. VMware, Inc. Appendix B Using vmkfstools  -L targetreset – Resets the entire target. The reset clears any reservations on all  the LUNs associated with that target and makes the LUNs available to all servers  again.   -L busreset – Resets all accessible targets on the bus. The reset clears any  reservation on all the LUNs accessible through the bus and makes them available  to all servers again.  When entering the  parameter, use the following format: /vmfs/devices/disks/vmhbaA:T:L:P See “vmkfstools Command Syntax” on page 283. VMware, Inc. 295 ESX Server 3 Configuration Guide 296 VMware, Inc. Index Symbols C * next to path 142 canonical paths 141 certificates certificate file 225 configuring ESX Server searches 228 disabling SSL for VI Web Access and SDK 227 key file 225 location 225 certification 175 changing password aging for ESX Server 243 password aging for users and groups 243 proxy services for ESX Server 228 service console password plugin 248 SSH configuration 253 checking authentication for iSCSI adapters 206 CIM and firewall ports 188 closing ports in the service console firewall 240 command reference for ESX Server 277 compatibility modes physical 151 virtual 151 configuring delegate user 233 ESX Server certificate searches 228 Fibre Channel storage 108 A accessing storage 95 adding Fibre Channel storage 108 groups to ESX Server hosts 224 iSCSI hardware-initiated storage 119 iSCSI software-initiated storage 125 local SCSI storage 104 NFS storage 129 users to ESX Server hosts 221 users to groups 224 Administrator role 218 asterisk next to path 142 authenticating groups 215 users 214 authentication daemon 211 B Blade servers and virtual networking 78 configuring a virtual machine port group 78 configuring a VMkernel port 79 VMware, Inc. 297 ESX Server 3 Configuration Guide hardware-initiated iSCSI storage 119 local SCSI storage 104 multipathing for Fibre Channel storage 143 password complexity 247 password reuse rules 246 RDM 155 software-initiated iSCSI storage 125 current multipathing state 141 D DAS firewall port for ESX Server 183 datastores adding extents 136 and file systems 91 configuring on NFS volumes 129 creating on Fibre Channel devices 108 creating on hardware-initiated iSCSI storage 119 creating on SCSI disk 104 creating on software-initiated iSCSI storage 125 managing 133 renaming 136 rescanning 126 viewing in VI Client 97 delegate user 232, 233 deployments for security 257 determining the firewall security level for the service console 238 DHCP 39 disabling authentication for iSCSI adapters 208 cut and paste for guest operating systems 264 298 limiting variable information size for guest operating systems 268 logging for guest operating systems 269, 273 SSL for VI Web Access and SDK 227 DNS 61 dynamic discovery 112 E encryption and enabling and disabling SSL 225 for user name, passwords, and packets 225 ESX Server adding groups 224 adding users 221 architecture and security features 164 authentication 211 authentication for iSCSI storage 205 changing proxy services 228 cipher strength for connections 249 command reference 277 delegate user 232 deployments and security 257 host to host firewall ports 188 password restrictions 241 security overview 164 users 211 virtual switch security 198 VLAN security 198 ESX Server host passwords aging 242 changing the plugin 248 complexity 244 configuring password complexity 247 VMware, Inc. Index configuring password reuse rules 246 new password criteria 244 esxcfg commands 277 EUI identifier 111 exporting ESX Server host users and groups 220 extents 136 F failover 55 failover paths status 142 Fibre Channel storage adding 108 overview 107 file systems managing 133 NFS 91 upgrading 135 VMFS 91 firewall ports and encryption 225 backup agents 237 CIM 188 configured with a VirtualCenter Server 179 configured without a VirtualCenter Server 182 determining the firewall security level for the service console 238 for connecting the virtual machine console 186 for management access 183 FTP 188 host to host 188 iSCSI software client 188 license server and VirtualCenter Server 179 VMware, Inc. management 188 NFS 188 NIS 188 opening and closing for the service console 240 opening with the VI Client 188 overview 177 SDK and the virtual machine console 186 security level 237 service console 237 setting the security level for the service console firewall 239 SMB 188 SNMP 188 SSH 188 supported services 188 VI Client and the virtual machine console 186 VI Client and VirtualCenter Server 179 VI Client direct connection 182 VI Web Access and the virtual machine console 186 VI Web Access and VirtualCenter Server 179 VI Web Access direct connection 182 Fixed path policy 137 FTP and firewall ports 188 G groups adding to ESX Server hosts 224 authentication 215 exporting a group list 220 Groups table for ESX Server hosts 219 modifying on ESX Server hosts 224 299 ESX Server 3 Configuration Guide removing from ESX Server hosts 225 viewing group lists 220 guest operating systems disabling cut and paste 264 disabling logging 269, 273 limiting variable information size 268 security recommendations 263 H HTTP and HTTPS firewall port 183 I IQN identifier 111 iSCSI authenticating 205 CHAP 205 checking authentication 206 configuring CHAP authentication 207 disabling authentication 208 firewall port for ESX Server 183 networking 73 protecting transmitted data 208 QLogic iSCSI adapters 204 security 204 software client and firewall ports 188 iSCSI hardware-initiated storage adding 119 overview 113 iSCSI HBA alias 115 CHAP authentication 118 CHAP parameters 115 dynamic discovery 115 static discovery 115 300 iSCSI networking creating a service console connection 76 creating a VMkernel port 74 iSCSI securing ports 208 iSCSI software-initiated storage adding 125 overview 121 iSCSI storage discovery methods 112 EUI identifier 111 hardware-initiated 110 initiators 110 IQN identifier 111 name formats 111 security 112 software-initiated 110 isolation virtual machine 165 virtual networking layer 169 virtual switches 169 VLANs 169 L Layer 2 security 51 license server firewall ports for 183 firewall ports with VirtualCenter Server 179 load balancing 55 local SCSI storage adding 104 overview 104 M MAC address configuring 68 generating 67 Manage Paths wizard 144 VMware, Inc. Index management access firewall ports 183 modifying groups on ESX Server hosts 224 users on ESX Server hosts 223 Most Recently Used path policy 137 multipathing active paths 142 canonical paths 141 dead paths 142 disabled paths 142 failover 143 managing 143 standby paths 142 multipathing policy setting 143 multipathing state 141 N NAS firewall port for ESX Server 183 mounting 70 Nessus 254 networking best practices 69 networks security 195 NFS delegate users 232 firewall ports 188 NFS storage adding 129 overview 127 NIC teaming definition 20 NIS and firewall ports 188 No Access role 218 VMware, Inc. O opening ports in the service console firewall 240 P pam_cracklib.so plugin 244 pam_passwdqc.so plugin 248 password restrictions aging 242 complexity 244 for the ESX Server host 241 minimum length 244 path failure 137 path policies Fixed 137 Most Recently Used 137 Round Robin 138 paths preferred 142, 144 permissions and privileges 215 overview 215 root user 215 VirtualCenter administrator 215 vpxuser 215 port group configuring 58 definition 20 using 24 preferred path 142, 144 preventing malicious device disconnection 266 privileges and permissions 215 proxy services and encryption 225 changing 228 301 ESX Server 3 Configuration Guide 302 R S raw device mapping see RDM 145 RDM advantages 147 and virtual disk files 154 and vmkfstools 158 creating 155 dynamic name resolution 152 overview 145 physical compatibility mode 151 virtual compatibility mode 151 with clustering 154 Read Only role 218 removing groups from ESX Server hosts 225 users from ESX Server hosts 224 users from groups 224 resource guarantees and security 165 resource limits and security 165 roles Administrator 218 and permissions 218 default 218 No Access 218 Read Only 218 root login delegate user 232 permissions 215 SSH 253 Round Robin path policy 138 routing 61 RPMs 254 SCSI vmkfstools 283 SDK and firewall ports for connecting to the virtual machine console 186 security CHAP authentication 205 cipher strength 249 delegate user 232 direct access users 214 encryption 225 ESX Server architecture 164 example, DMZ in a single ESX Server host 170, 172 forged transmissions 202 groups 215 iSCSI storage 204 MAC address changes 202 overview of users, groups, permissions, and roles 213 PAM authentication 211 password restrictions for the ESX Server host 241 patches 254 permissions 215 promiscuous mode 202 recommendations for virtual machines 263 roles 218 scanning software 254 security certificates 225 service console firewall security level 237 service console security measures 167 setgid applications 250 setuid applications 250 SSH connections 253 user authentication 211 VMware, Inc. Index user management 211 virtual machines 165 virtual network 195 virtual networking layer 169 VirtualCenter users 214 virtualization layer 164 VLAN hopping 198 VLANs 195 VMkernel 164 VMware policy 175 vmware-authd 211 service console direct connections 237 logging on 237 password restrictions 241 recommendations for securing 236 remote connections 237 securing with VLANs and virtual switches 198 security 167 setgid applications 250 setuid applications 250 SSH connections 253 service console networking configuration 34 troubleshooting 81 setgid applications 250 setting security level for the service console firewall 239 setting up CHAP authentication for iSCSI adapters 207 setuid applications 250 single point of failure 104 SMB and firewall ports 188 SNMP and firewall ports 188 SPOF 104 VMware, Inc. SSH changing configuration 253 firewall ports 188 security settings 253 static discovery 112 storage access for virtual machines 95 adapters 91 configuration tasks 101 Fibre Channel 107 iSCSI 110 local SCSI 104 NFS 127 SAN 107 securing with VLANs and virtual switches 198 types 88 viewing in VI Client 97 storage adapters Fibre Channel 107 iSCSI HBA 115 rescanning 126 viewing in VI Client 99 T TCP ports 183 third-party software support policy 175 Tomcat Web service 167 traffic shaping 53 U UDP ports 183 users adding to ESX Server hosts 221 authentication 214 direct access users 214 exporting a user list 220 from Windows domain 214 modifying on ESX Server hosts 223 303 ESX Server 3 Configuration Guide removing from ESX Server hosts 224 Users table for ESX Server hosts 219 viewing user list 220 VirtualCenter users 214 V VI Client firewall ports for connecting to the virtual machine console 186 firewall ports for direct connection 182 firewall ports with VirtualCenter Server 179 VI Web Access and ESX Server services 225 disabling SSL 227 firewall ports for connecting to the virtual machine console 186 firewall ports for direct connection 182 firewall ports with VirtualCenter Server 179 viewing ESX Server host users and groups 220 virtual machine networking 27 virtual machines configuring a delegate user 233 delegate user 232 disabling copy and paste 264 disabling logging 269, 273 isolation example 170, 172 limiting variable information size 268 preventing device disconnection 266 resource reservations and limits 165 304 security 165 security recommendations 263 virtual networking layer and security 169 virtual switches 802.1Q and ISL tagging attacks 200 and iSCSI 208 double-encapsulated attacks 200 forged transmissions 202 MAC address changes 202 MAC flooding 200 multicast brute-force attacks 200 promiscuous mode 202 random frame attacks 200 scenarios for deployment 257 security 200 spanning tree attacks 200 VirtualCenter Server firewall ports 179 permissions 215 virtualization layer and security 164 VLAN definition 20 VLANs and iSCSI 208 Layer 2 security 198 scenarios for deployment 257 security 195 VLAN hopping 198 VMFS sharing 257 vmkfstools 283 VMkernel configuring 30 definition 20 security 164 VMware, Inc. Index vmkfstools file system options 285 overview 283 syntax 283 virtual disk options 288 VMotion definition 20 firewall port 183 networking configuration 30 securing with VLANs and virtual switches 198 vSwitch definition 20 policies 50 using 21 VMware, Inc. 305 ESX Server 3 Configuration Guide 306 VMware, Inc. Updates for the ESX Server 3 Configuration Guide Last Updated: May 14, 2010 This document provides updates to the Update 2 release of the ESX Server 3  Configuration Guide for ESX Server 3.5 and VirtualCenter 2.5. Updated descriptions,  procedures, and graphics are organized by page number so that you can easily locate  the areas of the guide that have changes. If the change spans multiple sequential pages,  this document provides the starting page number only. The following are the updates to the ESX Server 3 Configuration Guide:  Updates for the Table of TCP and UPD Ports for Management Access on Page 185  Update for Description of SSL Behavior on Page 225  Update for Types of Certificates to Install for Certificate Checking on Page 226  Update for Using Third‐Party Applications to Upload Certificates on Page 227  Update for Certificates Supported for Encryption Over an SSL Connection on  Page 227  Updates to the Password Aging Section on Page 242  Updates for the To change default password complexity for the pam_cracklib.so  plug‐in Procedure on Page 247 Updates for the Table of TCP and UPD Ports for Management Access on Page 185 The information in Table 10‐1 for ports 5988 and 5989 is incorrect. Port 5988 is no longer  required for CIM traffic and should be closed, so information related to Port 5988  should be deleted from the table.  Port 5989 is open for CIM traffic on HTTPS instead of HTTP. The following row replaces  the information given for port 5989.  5989 VMware, Inc. CIM XML transactions over HTTPS.  Incoming and  outgoing TCP Update–1 Updates for the ESX Server 3 Configuration Guide Update for Description of SSL Behavior on Page 225 The Encryption and Security Certificates for ESX Server 3 section incorrectly describes  SSL behavior for ESX Server 3 and states that SSL is not enabled by default. The  corrected paragraph should appear as follows: SSL certificates are used to encrypt network traffic, but the certificate used for  encryption is not verified by default. Therefore, the connection between the VI Client  and VirtualCenter is vulnerable to a possible man‐in‐the‐middle attack. To prevent  such an attack and to fully enable the security provided by certificates in ESX Server 3,  you must enable certificate checking and install new certificates. Update for Types of Certificates to Install for Certificate Checking on Page 226 The paragraph after the To enable certificate checking procedure, describes how to  receive the full benefits of certificate checking, but does not specify what type of  certificates to install. The following information should be included: To receive the full benefit of certificate checking, install new certificates that are signed  by a valid internal or public CA. Update for Using Third-Party Applications to Upload Certificates on Page 227 The Adding Certificates and Modifying ESX Server 3 Web Proxy Settings section states  incorrectly that you should avoid setting up certificates by using pass phrases. The  section should state the following: Do not set up certificates by using pass phrases. ESX Server 3 does not support pass  phrases, also known as encrypted keys. If you set up a pass phrase, ESX Server 3  processes cannot start correctly. Update for Certificates Supported for Encryption Over an SSL Connection on Page 227 The Adding Certificates and Modifying ESX Server 3 Web Proxy Settings section omits  a note about what type of certificate is supported by ESX Server for encrypting session  information sent over an SSL connection. The section should include the following  information: ESX Server supports only X.509 certificates to encrypt session information sent over  SSL connections between server and client components. Update–2 VMware, Inc. Updates for the ESX Server 3 Configuration Guide Updates to the Password Aging Section on Page 242 The Password Aging section incorrectly states that the maximum number of days that  a user can retain a password is 90 days. The corrected list item should appear as follows: Maximum days – The number of days that a user can retain a password. By default,  passwords are set to never expire. Updates for the To change default password complexity for the pam_cracklib.so plug-in Procedure on Page 247 In the To change default password complexity for the pam_cracklib.so plug‐in  procedure, the information about credits and the example for  esxcfg-auth --usecrack command are incorrect. The content should be as follows:   represents lowercase letters   represents uppercase letters   represents digits   represents special characters, such as underscore or dash Credits add to a passwordʹs complexity score. A userʹs password must meet or exceed  the minimum score, which you define using the  parameter. NOTE   The pam_cracklib.so plug‐in does not accept passwords that are less than six  characters, regardless of credits used and regardless of the value you assign to  . In other words, if  is 5, users must still enter  no fewer than six characters. To determine whether or not a password is acceptable, the pam_cracklib.so plug‐in  uses several rules to calculate the password score.  Each character in the password, regardless of the type, counts as one against  .  Nonzero values in the credit parameters affect password complexity differently  depending on whether negative or positive values are used.  For positive values, add one credit for the character class, up to the maximum  number of credits specified by the credit parameter. For example, if  is 1, add one credit for using a lowercase letter  in the password. In this case, one is the maximum number of credits allowed  for lowercase letters, regardless of how many are used. VMware, Inc. Update–3 Updates for the ESX Server 3 Configuration Guide  For negative values, do not add credit for the character class, but mandate that  the character class is used a minimum number of times. The minimum  number is specified by the credit parameter. For example, if  is ‐1, passwords must contain at least one  uppercase character. In this case, no extra credit is given for using uppercase  letters, regardless of how many are used.  Character classes with a value of zero count toward the total length of the  password, but do not receive extra credit, nor are they required. You can set all  character classes to zero to enforce password length without considering  complexity. For example, the passwords xyzpqets and Xyzpq3#s would each have a password  score of eight. The plug‐in then compares the total score, or effective length, of the password to the  value of . Example of esxcfg-auth --usecrack Command esxcfg-auth --usecrack=3 9 1 -1 -1 1  Users are allowed three attempts to enter their password before they are locked  out.  The password score must be 9.  Up to one credit is given for using lowercase letters.  At least one uppercase letter is required. No extra credit is given for this character  class.  At least one digit is required. No extra credit is given for this character class.  Up to one credit is given for using special characters. Using these sample values, the password candidate xyzpqe# would fail. While the  password score is 9, (x + y + z + p +q + e + #) + (lc_credit + oc_credit) = 9, it does not  contain the required uppercase letter and digit. The password candidate Xyzpq3# would be accepted. The password score for this  example is also 9, (X + y + z + p +q + 3 + #) + (lc_credit + oc_credit) = 9, but this password  includes the required uppercase letter and digit. The uppercase letter and digit do not  add extra credit. Update–4 VMware, Inc.