3G/HD/SD/ASI/Routing Switcher
MFR-5000
3G/HD/SD/ASI/AES/Routing Switcher The MFR-5000 Series is a group of multi-format routing switchers supporting 3G-SDI, HD-SDI, SD-SDI, ASI and AES. Inside the 8 U case a matrix of up to 128 inputs/128 outputs can be configured. It offers expansive flexibility at the core of your system, such as tally connections with peripheral devices (video switchers and multi viewers) and automatic source name tracking. MFR-5000 Systems Specifications ● Video formats
3G HD: 1080/60p, 1080/59.94p, 1080/50p HD: 1080/60i, 1080/59.94i, 1080/50i, 1080/30p, 1080/30PsF, 1080/29.97p, 1080/29.97PsF, 1080/23.98p, 1080/23.98Psf, 1080/25p, 1080/25PsF, 1080/24PsF, 1080/24p, 720/60p, 720/59.94p, 720/50p SD: 525/60, 625/50 Min. 64 × 64 - Max. 128 × 128 + 4 monitoring outputs (Can be expanded in increments of 16 channels) Compliant with the following (75Ω, BNC) · SMPTE424M (3 Gbps) · SMPTE292M (1.5 Gbps) · SMPTE259M (270 Mbps) · DVB-ASI 3G/HD-SDI: 100 m (5C-FB or equivalent) SD-SDI: 200 m (5C-2V or equivalent) Compliant with the following (75Ω, BNC) (Auto reclocking) · SMPTE424M (3Gbps) · SMPTE292M (1.5 Gbps) · SMPTE259M (270 Mbps) · DVB-ASI 3G/HD/SD-SDI, DVB-ASI: 75Ω BNC × 4 (Auto reclocking not supported) AES/EBU · BNC × 16 (Stereo × 16) · Sampling Frequency: 32 kHz, 44.1 kHz, 48 kHz, 96 kHz AES/EBU (Only synchronized audio) · BNC × 8 (Stereo × 8) · Sampling Frequency: 48 kHz Embedded audio · BNC × 2 (Stereo × 8) · Sampling Frequency: 48 kHz Analog audio · 25-pin D-sub (female) (Stereo × 4) balanced or unbalanced · Output impedance: less than 100Ω · Sampling Frequency: 48 kHz
● Input × Output ● Video Inputs MFR-16SDI
● Cable Equalization ● Video Outputs MFR-16SDO
● Monitoring Outputs ● Audio Inputs MFR-16ADI ● Audio Outputs MFR-16ADAO
● Reference Inputs ● Interfaces ◆MFR-LAN:
◆PC-LAN: ◆ARCNET ◆SERIAL ◆ALARM ● Temperature / Humidity ● Power ● Consumption
● Dimensions / Weight ● Accessories ● Options
BB: NTSC: 0.429 Vp-p/PAL: 0.45 Vp-p or Tri-level Sync: ±0.3 Vp-p 75Ω, BNC × 2, Loop through (Terminate with 75Ω terminator, when unused)
Remote Control Unit Specifications ● Model Name ● Buttons/Colors
MFR-16RU 16 buttons (1 color only: green) user assignable
MFR-16RUD 16 buttons (1 color only: green) user assignable
3G/HD/SD/ASI/AES Routing Switcher
MFR-5000
10/100/1000 Base-T, RJ-45 × 2 (for connecting the RU/GPI unit. Up to 128 units can be connected) (The second LAN port is used in the redundant CPU configuration) 10/100 Base-TX, RJ-45 × 2 (for PC operation) (The second LAN port is used in the redundant CPU configuration) 10Mbps 75Ω or Loop through, BNC × 2 (Terminate with 75Ω terminator, when unused) (for video switcher HANABI series) RS-232C/RS-422 (Internal switch), 9-pin D-sub (male) × 1 9-pin D-sub (female) × 1 (Input: Reset /Output: Power, Fan Alarm) 0ºC - 40ºC / 30% - 85% (no condensation) 100 V AC - 240 V AC ±10%, 50/60Hz × 2 128 × 128, Dual CPU/Redundant Power Unit (Maximum Configuration): 390 VA at 100 V AC, 462 VA at 240 V AC 480 (W) × 354 (H) × 402.7 (D) mm; EIA 8 RU / Approx. 50 kg (Full option) Operation manual, AC cord, Rack mount bracket, AC cord retaining clip MFR-16RU: Remote Control Unit (16 buttons) MFR-16RUD: Remote Control Unit (16 buttons, LCD display) MFR-40RU: Remote Control Unit (40 buttons) MFR-18RU: Remote Control Unit (18 buttons, LCD display) MFR-39RU: Remote Control Unit (LCD 39 buttons, 10 buttons, menu display) MFR-GPI: GPI unit MFR-TALM: Tally manager MFR-CPU: Redundant CPU Card MFR-PS: Redundant Power Supply Unit MFR-16SDI: Digital Video Input Card MFR-16SDO: Digital Video Output Card MFR-16ADI: Digital Audio Input Card with Processing Function MFR-16ADAO: Digital Audio Output Card with Processing Function MFR-16AAI: Analog Audio Input Card MFR-16AESI: Digital Audio Input Card MFR-16AESO: Digital Audio Output Card
MFR-5000
MFR-GPI Specifications MFR-40RU 40 buttons (3-color: red/green/orange) user assignable
● Name Display
None
None
● Menu Display
None
● Rotary selector ● Number of Connections ● Interfaces ◆MFR-LAN: ◆SERVICE: ● Power ●Consumption ◆when AC 100V ◆when AC 240V ● Dimensions ● Weight ● Accessories
None Max. 128 units
Available None (Max. 16 characters × 2 lines) None None
None
MFR-18RU 18 buttons (3-color: red/green/orange) user assignable
MFR-39RU 39 buttons (LCD buttons, 7-color) user assignable 10 buttons (3-color: red/green/orange) user assignable Available (Displayed above Available (Displayed in each each button) button) LCD display × 18 LCD display × 39 (Max. 7 characters × 2 lines) (Max. 7 characters × 2 lines) Available None (Max. 23 characters × 2 lines) Available Available
10/100 Base-TX RJ-45 × 1 (for connection to MU; network hub required for connecting to multiple MUs) None RS-232C 9-pin D-sub (male) × 1 (for maintenance) None +12 VDC Pin-connector × 1 +12 VDC Pin-connector × 2 (redundant power supply as standard)
● Interfaces ◆GPI IN/TALLY OUT ◆Expand I/F
● Power ● Consumption ● Dimensions ● Weight ● Accessories
MFR-TALM Specifications ● Interfaces ◆MFR-LAN ◆PC-LAN ◆SERIAL ◆GPI IN/OUT
7VA 10VA 7VA 11VA 15VA 11VA 430 × 44 × 34 mm 430 × 44 × 42 mm 430 × 44 × 34 mm 1 kg 1 kg 2 kg AC adapter × 1, AC adapter connection kit × 1, rack mount bracket, LAN cable
12VA 18VA 430 × 44 × 42 mm 2 kg
17VA 22VA 430 × 88 × 44 mm 3 kg
37-pin D-sub (female) × 4 128 input/output (I/O composition is optional) RS-232C/422: 9-pin D-sub (male) × 4 See the Remote Control Unit Specifications. 17 VA (when 100 V AC), 22 VA (when 240 V AC) 430 (W) × 44 (H) × 110 (D) mm 2 kg See the Remote Control Unit Specifications.
◆REF IN ● Power ● Consumption ● Dimensions ● Weight ● Accessories
10/100/1000 Base-T RJ-45 × 1 (For connecting to the main unit) 10/100 Base-TX RJ-45 × 1 (For connecting a PC or external device) RS-422: 9-pin D-sub (male) × 4 37-pin D-sub (female) × 1 (GPI connector for external control) BB or Tri-level Sync, BNC × 1 See the Remote Control Unit Specifications. 17 VA (when 100 V AC), 20 VA (when 240 V AC) 212 (W) × 44 (H) × 161 (D) mm 2 kg See the Remote Control Unit Specifications.
FOR-A COMPANY LIMITED
URL: http://www.for-a.com/
Head Office: 3-8-1 Ebisu, Shibuya-ku, Tokyo 150-0013, Japan Tel : +81 (0)3-3446-3936 FOR-A Corporation of America: 11155 Knott Ave., Suite G&H, Cypress, CA 90630, U.S.A. Tel: +1-714-894-3311 FOR-A Corporation of America East Coast Office: 2 Executive Drive, Suite 670, Fort Lee Executive Park, Fort Lee NJ 07024, U.S.A. Tel: +1-201-944-1120 FOR-A Corporation of America Distribution & Service Center: 2400 N.E. Waldo Road, Gainesville, FL 32609, U.S.A. Tel: +1-352-371-1505 FOR-A Corporation of America Miami Office: 5200 Blue Lagoon Drive, Suite 760, Miami, FL 33126, U.S.A. Tel: +1-305-931-1700 FOR-A Corporation of Canada: 346A Queen Street West, Toronto, Ontario M5V 2A2, CANADA Tel: +1-416-977-0343 FOR-A UK Limited: Unit C71, Barwell Business Park, Leatherhead Road, Chessington Surrey, KT9 2NY, UK Tel: +44 (0)20-8391-7979 FOR-A Italia S.r.l.: Via Volturno, 37, 20047, Brugherio MB, Italy Tel: +39-039-881-086/103 FOR-A Corporation of Korea: 1007, 57-5,Yangsan-ro,Yeongdeungpo-gu, Seoul 150-103, Korea Tel: +82 (0)2-2637-0761 FOR-A China Limited: 708B Huateng Building, No. 302, 3 District, Jinsong, Chaoyang, Beijing 100021, China Tel: +86 (0)10-8721-6023 FOR-A Middle East-Africa Office: Jebel Ali Free Zone, LOB-16, Office 619, P.O. Box 261914, Dubai, U.A.E. Tel: +971 4 887 6712
Fax : +81 (0)3-3446-1470 Fax: +1-714-894-5399 Fax: +1-201-944-1132 Fax: +1-352-378-5320 Fax: +1-305-264-7890 Fax: +1-416-977-0657 Fax: +44 (0)20-8391-7978 Fax: +39-039-878-140 Fax: +82 (0)2-2637-0760 Fax: +86 (0)10-8721-6033 Fax: +971 4 887 6713
ISO 9001 and 14001 certified (Sakura R&D) © 2013 FOR-A Company Ltd. FOR-A is a registered trademark of FOR-A Company Ltd. Design and specifications subject to change without notice. Printed in Japan. 1301FJ2C
3G/HD/SD/ASI/Routing Switcher
MFR-5000
3G/HD/SD/ASI/AES/Routing Switcher The MFR-5000 Series is a group of multi-format routing switchers supporting 3G-SDI, HD-SDI, SD-SDI, ASI and AES. Inside the 8 U case a matrix of up to 128 inputs/128 outputs can be configured. It offers expansive flexibility at the core of your system, such as tally connections with peripheral devices (video switchers and multi viewers) and automatic source name tracking. MFR-5000 Systems Specifications ● Video formats
3G HD: 1080/60p, 1080/59.94p, 1080/50p HD: 1080/60i, 1080/59.94i, 1080/50i, 1080/30p, 1080/30PsF, 1080/29.97p, 1080/29.97PsF, 1080/23.98p, 1080/23.98Psf, 1080/25p, 1080/25PsF, 1080/24PsF, 1080/24p, 720/60p, 720/59.94p, 720/50p SD: 525/60, 625/50 Min. 64 × 64 - Max. 128 × 128 + 4 monitoring outputs (Can be expanded in increments of 16 channels) Compliant with the following (75Ω, BNC) · SMPTE424M (3 Gbps) · SMPTE292M (1.5 Gbps) · SMPTE259M (270 Mbps) · DVB-ASI 3G/HD-SDI: 100 m (5C-FB or equivalent) SD-SDI: 200 m (5C-2V or equivalent) Compliant with the following (75Ω, BNC) (Auto reclocking) · SMPTE424M (3Gbps) · SMPTE292M (1.5 Gbps) · SMPTE259M (270 Mbps) · DVB-ASI 3G/HD/SD-SDI, DVB-ASI: 75Ω BNC × 4 (Auto reclocking not supported) AES/EBU · BNC × 16 (Stereo × 16) · Sampling Frequency: 32 kHz, 44.1 kHz, 48 kHz, 96 kHz AES/EBU (Only synchronized audio) · BNC × 8 (Stereo × 8) · Sampling Frequency: 48 kHz Embedded audio · BNC × 2 (Stereo × 8) · Sampling Frequency: 48 kHz Analog audio · 25-pin D-sub (female) (Stereo × 4) balanced or unbalanced · Output impedance: less than 100Ω · Sampling Frequency: 48 kHz
● Input × Output ● Video Inputs MFR-16SDI
● Cable Equalization ● Video Outputs MFR-16SDO
● Monitoring Outputs ● Audio Inputs MFR-16ADI ● Audio Outputs MFR-16ADAO
● Reference Inputs ● Interfaces ◆MFR-LAN:
◆PC-LAN: ◆ARCNET ◆SERIAL ◆ALARM ● Temperature / Humidity ● Power ● Consumption
● Dimensions / Weight ● Accessories ● Options
BB: NTSC: 0.429 Vp-p/PAL: 0.45 Vp-p or Tri-level Sync: ±0.3 Vp-p 75Ω, BNC × 2, Loop through (Terminate with 75Ω terminator, when unused)
Remote Control Unit Specifications ● Model Name ● Buttons/Colors
MFR-16RU 16 buttons (1 color only: green) user assignable
MFR-16RUD 16 buttons (1 color only: green) user assignable
3G/HD/SD/ASI/AES Routing Switcher
MFR-5000
10/100/1000 Base-T, RJ-45 × 2 (for connecting the RU/GPI unit. Up to 128 units can be connected) (The second LAN port is used in the redundant CPU configuration) 10/100 Base-TX, RJ-45 × 2 (for PC operation) (The second LAN port is used in the redundant CPU configuration) 10Mbps 75Ω or Loop through, BNC × 2 (Terminate with 75Ω terminator, when unused) (for video switcher HANABI series) RS-232C/RS-422 (Internal switch), 9-pin D-sub (male) × 1 9-pin D-sub (female) × 1 (Input: Reset /Output: Power, Fan Alarm) 0ºC - 40ºC / 30% - 85% (no condensation) 100 V AC - 240 V AC ±10%, 50/60Hz × 2 128 × 128, Dual CPU/Redundant Power Unit (Maximum Configuration): 390 VA at 100 V AC, 462 VA at 240 V AC 480 (W) × 354 (H) × 402.7 (D) mm; EIA 8 RU / Approx. 50 kg (Full option) Operation manual, AC cord, Rack mount bracket, AC cord retaining clip MFR-16RU: Remote Control Unit (16 buttons) MFR-16RUD: Remote Control Unit (16 buttons, LCD display) MFR-40RU: Remote Control Unit (40 buttons) MFR-18RU: Remote Control Unit (18 buttons, LCD display) MFR-39RU: Remote Control Unit (LCD 39 buttons, 10 buttons, menu display) MFR-GPI: GPI unit MFR-TALM: Tally manager MFR-CPU: Redundant CPU Card MFR-PS: Redundant Power Supply Unit MFR-16SDI: Digital Video Input Card MFR-16SDO: Digital Video Output Card MFR-16ADI: Digital Audio Input Card with Processing Function MFR-16ADAO: Digital Audio Output Card with Processing Function MFR-16AAI: Analog Audio Input Card MFR-16AESI: Digital Audio Input Card MFR-16AESO: Digital Audio Output Card
MFR-5000
MFR-GPI Specifications MFR-40RU 40 buttons (3-color: red/green/orange) user assignable
● Name Display
None
None
● Menu Display
None
● Rotary selector ● Number of Connections ● Interfaces ◆MFR-LAN: ◆SERVICE: ● Power ●Consumption ◆when AC 100V ◆when AC 240V ● Dimensions ● Weight ● Accessories
None Max. 128 units
Available None (Max. 16 characters × 2 lines) None None
None
MFR-18RU 18 buttons (3-color: red/green/orange) user assignable
MFR-39RU 39 buttons (LCD buttons, 7-color) user assignable 10 buttons (3-color: red/green/orange) user assignable Available (Displayed above Available (Displayed in each each button) button) LCD display × 18 LCD display × 39 (Max. 7 characters × 2 lines) (Max. 7 characters × 2 lines) Available None (Max. 23 characters × 2 lines) Available Available
10/100 Base-TX RJ-45 × 1 (for connection to MU; network hub required for connecting to multiple MUs) None RS-232C 9-pin D-sub (male) × 1 (for maintenance) None +12 VDC Pin-connector × 1 +12 VDC Pin-connector × 2 (redundant power supply as standard)
● Interfaces ◆GPI IN/TALLY OUT ◆Expand I/F
● Power ● Consumption ● Dimensions ● Weight ● Accessories
MFR-TALM Specifications ● Interfaces ◆MFR-LAN ◆PC-LAN ◆SERIAL ◆GPI IN/OUT
7VA 10VA 7VA 11VA 15VA 11VA 430 × 44 × 34 mm 430 × 44 × 42 mm 430 × 44 × 34 mm 1 kg 1 kg 2 kg AC adapter × 1, AC adapter connection kit × 1, rack mount bracket, LAN cable
12VA 18VA 430 × 44 × 42 mm 2 kg
17VA 22VA 430 × 88 × 44 mm 3 kg
37-pin D-sub (female) × 4 128 input/output (I/O composition is optional) RS-232C/422: 9-pin D-sub (male) × 4 See the Remote Control Unit Specifications. 17 VA (when 100 V AC), 22 VA (when 240 V AC) 430 (W) × 44 (H) × 110 (D) mm 2 kg See the Remote Control Unit Specifications.
◆REF IN ● Power ● Consumption ● Dimensions ● Weight ● Accessories
10/100/1000 Base-T RJ-45 × 1 (For connecting to the main unit) 10/100 Base-TX RJ-45 × 1 (For connecting a PC or external device) RS-422: 9-pin D-sub (male) × 4 37-pin D-sub (female) × 1 (GPI connector for external control) BB or Tri-level Sync, BNC × 1 See the Remote Control Unit Specifications. 17 VA (when 100 V AC), 20 VA (when 240 V AC) 212 (W) × 44 (H) × 161 (D) mm 2 kg See the Remote Control Unit Specifications.
FOR-A COMPANY LIMITED
URL: http://www.for-a.com/
Head Office: 3-8-1 Ebisu, Shibuya-ku, Tokyo 150-0013, Japan Tel : +81 (0)3-3446-3936 FOR-A Corporation of America: 11155 Knott Ave., Suite G&H, Cypress, CA 90630, U.S.A. Tel: +1-714-894-3311 FOR-A Corporation of America East Coast Office: 2 Executive Drive, Suite 670, Fort Lee Executive Park, Fort Lee NJ 07024, U.S.A. Tel: +1-201-944-1120 FOR-A Corporation of America Distribution & Service Center: 2400 N.E. Waldo Road, Gainesville, FL 32609, U.S.A. Tel: +1-352-371-1505 FOR-A Corporation of America Miami Office: 5200 Blue Lagoon Drive, Suite 760, Miami, FL 33126, U.S.A. Tel: +1-305-931-1700 FOR-A Corporation of Canada: 346A Queen Street West, Toronto, Ontario M5V 2A2, CANADA Tel: +1-416-977-0343 FOR-A UK Limited: Unit C71, Barwell Business Park, Leatherhead Road, Chessington Surrey, KT9 2NY, UK Tel: +44 (0)20-8391-7979 FOR-A Italia S.r.l.: Via Volturno, 37, 20047, Brugherio MB, Italy Tel: +39-039-881-086/103 FOR-A Corporation of Korea: 1007, 57-5,Yangsan-ro,Yeongdeungpo-gu, Seoul 150-103, Korea Tel: +82 (0)2-2637-0761 FOR-A China Limited: 708B Huateng Building, No. 302, 3 District, Jinsong, Chaoyang, Beijing 100021, China Tel: +86 (0)10-8721-6023 FOR-A Middle East-Africa Office: Jebel Ali Free Zone, LOB-16, Office 619, P.O. Box 261914, Dubai, U.A.E. Tel: +971 4 887 6712
Fax : +81 (0)3-3446-1470 Fax: +1-714-894-5399 Fax: +1-201-944-1132 Fax: +1-352-378-5320 Fax: +1-305-264-7890 Fax: +1-416-977-0657 Fax: +44 (0)20-8391-7978 Fax: +39-039-878-140 Fax: +82 (0)2-2637-0760 Fax: +86 (0)10-8721-6033 Fax: +971 4 887 6713
ISO 9001 and 14001 certified (Sakura R&D) © 2013 FOR-A Company Ltd. FOR-A is a registered trademark of FOR-A Company Ltd. Design and specifications subject to change without notice. Printed in Japan. 1301FJ2C
1 U compact type 16 buttons: lights in green only Any function can be assigned to the16 buttons Equipped with a display showing status and setting menu display
SNMP Support
Outstanding Maintainability
Designed for maintainability, all boards and power units can be accessed from the front without removing cables.
MFR-39RU
MFR-GPI MFR-16RU
MFR-40RU
■ ■ ■ ■
1 U compact type 40 buttons: light in 3 colors (red/green/orange) Any function can be assigned to any button Power source redundant (AC adapter)
MFR-40RU
DVI
DVI
RS-422 1/2/3/4 REF-IN
■ 2 U type ■ 39 buttons: 13 buttons in 3 rows. Buttons with LCD display that can show source names or assigned functions (7-color: red/green/yellow/blue/white/cyan/magenta) ■ Apart from the main buttons, there are 10 function buttons that can be freely assigned (Light in 3 colors: red/green/orange) ■ Equipped with display showing status and setting menu display ■ Ideal as a main control unit covering the entire crosspoint set-up ■ Power source redundant (AC adapter)
PREV monitor
Video Switcher HVS-4000
MV monitor 1
MFR-LAN
PC-LAN
MFR-18RU
MV monitor 2 Multi Viewer MV-3200
DVI
MV monitor 3 DVI
MFR-TALM MFR-39RU
Ethernet Hub
Ethernet Hub
MV monitor 4
GUI
MFR-5000 Rear Panel
MFR-16RU/16RUD/40RU/18RU External Dimensions 430
Supports Combinations of Multiple Remote Control Units
Multiple remote control units can be combined to make them function as a large scale control panel. Combination example: ■ For 128 × 128 full control + system settings: MFR-40RU × 4 + MFR-39RU × 1
2
3
4
(CPU2)
(CPU2)
PC-LAN
1
REF IN
2
IN 1
IN
3
4
1
IN 1
IN
5
1
6
IN 7
1
IN 1
8
OUT 1
1
OUT 1
OUT
2
1
3
OUT 1
4
OUT 1
5
OUT 6
1
OUT 1
7
8
SETUP
LOCK
RESET
PAGE
▲ MFR-16RU
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1
2
3
4
5
6
7
8
3G/HD/SD-SDI OUTPUT 1
2
3
4
5
6
7
BUSY
SETUP
LOCK
RESET
8
8
8
8
8
8
8
8
8
8
8
8
8
8
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
CANCEL
MFR-16RUD
REMOTE CONTROL UNIT
34
480
▲ MFR-16RUD MFR-LAN
RATING LABEL
8
8
9
ENTER
PAGE
8
DC12V IN
10
LOCK POWER
SLOT
OUT
BUSY
OUT 1
3G/HD/SD-SDI INPUT
IN
2
2
IN 1
REMOTE CONTROL UNIT
POWER
(CPU1) SERIAL
ARCNET
1 1
IN
MFR-16RU
LOCK (CPU1)
ALARM
IN OUT SYSTEM SETTING
2.3
MFR-LAN
MONITOR OUT (SDI)
32 44
1
▲ MFR-16RU/16RUD Rear Panel
430
2.3 REMOTE CONTROL UNIT
MFR-40RU
POWER
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
BUSY
SETUP
LOCK
RESET
▲ MFR-40RU 1
2
MFR-18RU
REMOTE CONTROL UNIT
Interface Expansion Unit
AC100-240V 50/60Hz IN
Remote monitoring by SNMP is supported and the router can easily be integrated into an SNMP monitoring system. In this way you can monitor the status of various items including: power source, fan, CPU, presence/absence of signals, crosspoint errors and more.
Routing Switcher MFR-5000 128 × 128
MFR-16RUD
One routing switcher can be virtually partitioned to build any theoretical hierarchy, creating possibilities for use in various operations. Examples: ■ Fully independent switching: a single unit can be used as multiple routing switchers by making multiple matrix partitions. This is effective when you wish to do multiple operations while avoiding source sharing. ■ V/Key linking switcher: allows two inputs to be linked for routing of video and key signals together. ■ 3D switcher: partition the matrix in two and control the left and right channels from a 3D source simultaneously. ■ HD/SD simul-switcher: provides simultaneous control of HD and SD sources. Perfect feature for HD/SD master control switching.
MFR-LAN
AC100-240V 50/60Hz IN
Redundancy Features ■ CPU board redundancy (option): a secondary CPU board constantly monitors the operation of the primary board. If the secondary CPU board detects any faults, operation is immediately switched to the secondary CPU to allow for continuous operation without down time. ■ Redundant power supply (option): in the rare event of a power supply problem, the second supply takes over to avoid any interruption of router function. ■ Network redundancy (option): a secondary Ethernet connection provides back-up for system control. With CPU redundancy, each interface can also have a backup (for details see below). ■ Direct control of main unit: the main unit has an LED display on the front. It can display settings and alarms.
■ ■ ■ ■
SDI
PC-LAN
32 44
Since routing switchers are the core of large video systems, we have engineered a variety of features to ensure full redundancy.
MFR-16RUD
PGM monitor
SDI
■ 1 U compact type ■ 18 buttons: light in 3 colors (red/green/orange) ■ Equipped with LCD display that can show source name and assigned functions for each button (7-color: red/green/yellow/blue/white/cyan/magenta) ■ Any function can be assigned to any button ■ Power source redundant (AC adapter)
32 44
Outstanding Redundancy
■ 1 U compact type ■ 16 buttons: light in green only ■ Any function can be assigned to the16 buttons
POWER
BUSY
SETUP
LOCK
RESET
32 44
The input/output board has 16 channels and up to 8 boards can be installed together. As a result, matrices of up to 128 input/128 output can be configured.
REF-TH
MFR-5000 External Dimensions
42
480
▲ MFR-18RU MFR-LAN
2
SERVICE
t2.3
RATING LABEL CPU 1
The interface expansion unit lineup includes two types to suit your specific application. The number of units that can be connected is a maximum of 128, including the remote control units.
CPU 2
MESSAGE/MENU
ALARM
ACTIVE
MESSAGE/MENU
ALARM
ACTIVE
1
DC12V IN
▲ MFR-40RU/18RU Rear Panel
MFR-39RU External Dimensions 430
2.3
POWER 1
ON
REMOTE CONTROL UNIT
OFF
MFR-GPI: GPI Unit
MFR-TALM: Tally Manager
ROUTING SWITCHER
MFR-5000
MFR-39RU
POWER
BUSY
LOCK
SETUP
CANCEL
RESET
POWER 2
Interface details
76 88
Configuring Matrices (up to 128 Input/128 Output)
Matrix Partition Function
From System
REF-IN
Tally/name data
Audio input/output card ■ MFR-16AESI (to be released in spring 2013): Input card for 16 stereo-pair (32 channels) AES/EBU ■ MFR-16ADI: Input card with processing function for 16 stereo-pair (32 channels) AES/EBU ■ MFR-16AESO (to be released in spring 2013): Output card for 16 stereo-pair (32 channels) AES/EBU ■ MFR-16ADAO: Output card enables support for 2 SDI embedded audio, 8 stereo-pair (16 channels) AES/EBU and 8ch analog audio. ■ MFR-16AAI: (to be supported in the future) Input card supported for 32 channels analog audio.
SDI
Name information
Audio input and output cards are available for the MFR-5000 in addition to video I/O cards. This allows for a combined audio/video router in a single cabinet along with A/D and D/A conversion, plus embedding and de-embedding operations.
MFR-18RU
Tally data
Various Audio Input and Output Support
MFR-16RU
37.4
■ Salvo function (1) Button-assigned Salvo: multiple crosspoints can be assigned to any button. Separate settings can be made for each remote unit. (2) Main unit storage Salvo: multiple crosspoints can be stored on the main unit side and shared by all remote units. ■ Take operation: after presetting crosspoints, press the Take button to change the set crosspoints. (1) Mode-switching Take button: switches between take operation and usual operation (instant execution). (2) Always Take button: always performs take. ■ Link function: this can group and link multiple crosspoints. ■ Level operation: level switching allows separate control over different subject types. ■ Chop function: allows user to switch between two sources for a destination. ■ Monitor out: enables output of any destination source to a dedicated monitoring channel. ■ Prevention of incorrect operation: - Inhibit: Crosspoint, Source, Destination - Lock: Lock Other / Lock All / Lock Local
A variety crosspoint control features are possible in addition to normal crosspoint switching.
The MFR-5000 enables tally linking with FOR-A’s video switcher HANABI Series and multi viewer MV Series. And when switching between sources on the MFR-5000 side, the source name displayed by the video switcher or multi viewer can also change automatically. It supports TSL and Harris protocol, enabling linkage with 3rd party equipment.
101.5
Video input/output card ■ MFR-16SDI: 16-input card enables support for 3G/HD/SD-SDI and ASI ■ MFR-16SDO: 16-output card enables support for 3G/HD/SD-SDI and ASI
Input and output support for: 3G-SDI, HD-SDI, SD-SDI and ASI, with automatic detection of signal type.
We offer several types or remote control to suit your application. The number of units that can be connected is a maximum of 128, including the main unit. This lets you build a flexible control environment by the way you partition the matrix and make operation level settings.
76.2 354
Various Crosspoint Control
System Links with Other Products
101.4
Multi-Format Support
Remote Control Units
Tally/name data
Main Features of MFR-5000
ON
480
37.5
OFF
Ethernet
RJ-45
2
4
Serial
9 pin D-sub (male)
1
1
Alarm output
9 pin D-sub (female)
1
1
ARCNET
BNC
2
2
401.7
Provides an interface for GPI control. This 1 RU sized unit is equipped with user-assignable GPI/O (128 channels) and 4 serial ports (9-pin D-sub male). It can be used for setting Input/Output and supports system configuration.
MFR-TALM is a device for performing central management of tally and material names of the MFR main unit and peripheral devices (such as video switchers and multi viewers). In the tally linking system like the one shown to the right (Fig. 1), MFR-TALM performs the tally calculation, which were originally performed by the MFR main unit, so that the tally linking can be speeded up.
1
DC12V IN
MFR-GPI External Dimensions
MFR-TALM External Dimensions
2.3
430 GPI UNIT
161
211 POWER
SERIAL
1
2
3
4
BUSY
SERIAL GPI
1
2
3
4
MFR-GPI
32 44
With redundant CPU installed
RESET
MFR-TALM TALLT MANAGER UNIT 1
PC-LAN
MFR-LAN
REF IN
DC12V IN
44
Standard configuration
2
RATING LABEL
SERIAL
2
POWER
BUSY
REF IN
GPI
1
2
3
4
RESET
480
110
GPI SERVICE
SER. No.
28
▲ MFR-TALM Rear Panel
105
28
21
170
▲ MFR-TALM External Dimensions
21
1
2
SERIAL
3
4
3.6
Connector
44
MFR-LAN SERVICE
429 462 480
MFR-LAN
GPI 1
GPI 2
RATING LABEL
GPI 3
GPI 4
2 - DC12V IN - 1
1 U compact type 16 buttons: lights in green only Any function can be assigned to the16 buttons Equipped with a display showing status and setting menu display
SNMP Support
Outstanding Maintainability
Designed for maintainability, all boards and power units can be accessed from the front without removing cables.
MFR-39RU
MFR-GPI MFR-16RU
MFR-40RU
■ ■ ■ ■
1 U compact type 40 buttons: light in 3 colors (red/green/orange) Any function can be assigned to any button Power source redundant (AC adapter)
MFR-40RU
DVI
DVI
RS-422 1/2/3/4 REF-IN
■ 2 U type ■ 39 buttons: 13 buttons in 3 rows. Buttons with LCD display that can show source names or assigned functions (7-color: red/green/yellow/blue/white/cyan/magenta) ■ Apart from the main buttons, there are 10 function buttons that can be freely assigned (Light in 3 colors: red/green/orange) ■ Equipped with display showing status and setting menu display ■ Ideal as a main control unit covering the entire crosspoint set-up ■ Power source redundant (AC adapter)
PREV monitor
Video Switcher HVS-4000
MV monitor 1
MFR-LAN
PC-LAN
MFR-18RU
MV monitor 2 Multi Viewer MV-3200
DVI
MV monitor 3 DVI
MFR-TALM MFR-39RU
Ethernet Hub
Ethernet Hub
MV monitor 4
GUI
MFR-5000 Rear Panel
MFR-16RU/16RUD/40RU/18RU External Dimensions 430
Supports Combinations of Multiple Remote Control Units
Multiple remote control units can be combined to make them function as a large scale control panel. Combination example: ■ For 128 × 128 full control + system settings: MFR-40RU × 4 + MFR-39RU × 1
2
3
4
(CPU2)
(CPU2)
PC-LAN
1
REF IN
2
IN 1
IN
3
4
1
IN 1
IN
5
1
6
IN 7
1
IN 1
8
OUT 1
1
OUT 1
OUT
2
1
3
OUT 1
4
OUT 1
5
OUT 6
1
OUT 1
7
8
SETUP
LOCK
RESET
PAGE
▲ MFR-16RU
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1
2
3
4
5
6
7
8
3G/HD/SD-SDI OUTPUT 1
2
3
4
5
6
7
BUSY
SETUP
LOCK
RESET
8
8
8
8
8
8
8
8
8
8
8
8
8
8
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
CANCEL
MFR-16RUD
REMOTE CONTROL UNIT
34
480
▲ MFR-16RUD MFR-LAN
RATING LABEL
8
8
9
ENTER
PAGE
8
DC12V IN
10
LOCK POWER
SLOT
OUT
BUSY
OUT 1
3G/HD/SD-SDI INPUT
IN
2
2
IN 1
REMOTE CONTROL UNIT
POWER
(CPU1) SERIAL
ARCNET
1 1
IN
MFR-16RU
LOCK (CPU1)
ALARM
IN OUT SYSTEM SETTING
2.3
MFR-LAN
MONITOR OUT (SDI)
32 44
1
▲ MFR-16RU/16RUD Rear Panel
430
2.3 REMOTE CONTROL UNIT
MFR-40RU
POWER
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
BUSY
SETUP
LOCK
RESET
▲ MFR-40RU 1
2
MFR-18RU
REMOTE CONTROL UNIT
Interface Expansion Unit
AC100-240V 50/60Hz IN
Remote monitoring by SNMP is supported and the router can easily be integrated into an SNMP monitoring system. In this way you can monitor the status of various items including: power source, fan, CPU, presence/absence of signals, crosspoint errors and more.
Routing Switcher MFR-5000 128 × 128
MFR-16RUD
One routing switcher can be virtually partitioned to build any theoretical hierarchy, creating possibilities for use in various operations. Examples: ■ Fully independent switching: a single unit can be used as multiple routing switchers by making multiple matrix partitions. This is effective when you wish to do multiple operations while avoiding source sharing. ■ V/Key linking switcher: allows two inputs to be linked for routing of video and key signals together. ■ 3D switcher: partition the matrix in two and control the left and right channels from a 3D source simultaneously. ■ HD/SD simul-switcher: provides simultaneous control of HD and SD sources. Perfect feature for HD/SD master control switching.
MFR-LAN
AC100-240V 50/60Hz IN
Redundancy Features ■ CPU board redundancy (option): a secondary CPU board constantly monitors the operation of the primary board. If the secondary CPU board detects any faults, operation is immediately switched to the secondary CPU to allow for continuous operation without down time. ■ Redundant power supply (option): in the rare event of a power supply problem, the second supply takes over to avoid any interruption of router function. ■ Network redundancy (option): a secondary Ethernet connection provides back-up for system control. With CPU redundancy, each interface can also have a backup (for details see below). ■ Direct control of main unit: the main unit has an LED display on the front. It can display settings and alarms.
■ ■ ■ ■
SDI
PC-LAN
32 44
Since routing switchers are the core of large video systems, we have engineered a variety of features to ensure full redundancy.
MFR-16RUD
PGM monitor
SDI
■ 1 U compact type ■ 18 buttons: light in 3 colors (red/green/orange) ■ Equipped with LCD display that can show source name and assigned functions for each button (7-color: red/green/yellow/blue/white/cyan/magenta) ■ Any function can be assigned to any button ■ Power source redundant (AC adapter)
32 44
Outstanding Redundancy
■ 1 U compact type ■ 16 buttons: light in green only ■ Any function can be assigned to the16 buttons
POWER
BUSY
SETUP
LOCK
RESET
32 44
The input/output board has 16 channels and up to 8 boards can be installed together. As a result, matrices of up to 128 input/128 output can be configured.
REF-TH
MFR-5000 External Dimensions
42
480
▲ MFR-18RU MFR-LAN
2
SERVICE
t2.3
RATING LABEL CPU 1
The interface expansion unit lineup includes two types to suit your specific application. The number of units that can be connected is a maximum of 128, including the remote control units.
CPU 2
MESSAGE/MENU
ALARM
ACTIVE
MESSAGE/MENU
ALARM
ACTIVE
1
DC12V IN
▲ MFR-40RU/18RU Rear Panel
MFR-39RU External Dimensions 430
2.3
POWER 1
ON
REMOTE CONTROL UNIT
OFF
MFR-GPI: GPI Unit
MFR-TALM: Tally Manager
ROUTING SWITCHER
MFR-5000
MFR-39RU
POWER
BUSY
LOCK
SETUP
CANCEL
RESET
POWER 2
Interface details
76 88
Configuring Matrices (up to 128 Input/128 Output)
Matrix Partition Function
From System
REF-IN
Tally/name data
Audio input/output card ■ MFR-16AESI (to be released in spring 2013): Input card for 16 stereo-pair (32 channels) AES/EBU ■ MFR-16ADI: Input card with processing function for 16 stereo-pair (32 channels) AES/EBU ■ MFR-16AESO (to be released in spring 2013): Output card for 16 stereo-pair (32 channels) AES/EBU ■ MFR-16ADAO: Output card enables support for 2 SDI embedded audio, 8 stereo-pair (16 channels) AES/EBU and 8ch analog audio. ■ MFR-16AAI: (to be supported in the future) Input card supported for 32 channels analog audio.
SDI
Name information
Audio input and output cards are available for the MFR-5000 in addition to video I/O cards. This allows for a combined audio/video router in a single cabinet along with A/D and D/A conversion, plus embedding and de-embedding operations.
MFR-18RU
Tally data
Various Audio Input and Output Support
MFR-16RU
37.4
■ Salvo function (1) Button-assigned Salvo: multiple crosspoints can be assigned to any button. Separate settings can be made for each remote unit. (2) Main unit storage Salvo: multiple crosspoints can be stored on the main unit side and shared by all remote units. ■ Take operation: after presetting crosspoints, press the Take button to change the set crosspoints. (1) Mode-switching Take button: switches between take operation and usual operation (instant execution). (2) Always Take button: always performs take. ■ Link function: this can group and link multiple crosspoints. ■ Level operation: level switching allows separate control over different subject types. ■ Chop function: allows user to switch between two sources for a destination. ■ Monitor out: enables output of any destination source to a dedicated monitoring channel. ■ Prevention of incorrect operation: - Inhibit: Crosspoint, Source, Destination - Lock: Lock Other / Lock All / Lock Local
A variety crosspoint control features are possible in addition to normal crosspoint switching.
The MFR-5000 enables tally linking with FOR-A’s video switcher HANABI Series and multi viewer MV Series. And when switching between sources on the MFR-5000 side, the source name displayed by the video switcher or multi viewer can also change automatically. It supports TSL and Harris protocol, enabling linkage with 3rd party equipment.
101.5
Video input/output card ■ MFR-16SDI: 16-input card enables support for 3G/HD/SD-SDI and ASI ■ MFR-16SDO: 16-output card enables support for 3G/HD/SD-SDI and ASI
Input and output support for: 3G-SDI, HD-SDI, SD-SDI and ASI, with automatic detection of signal type.
We offer several types or remote control to suit your application. The number of units that can be connected is a maximum of 128, including the main unit. This lets you build a flexible control environment by the way you partition the matrix and make operation level settings.
76.2 354
Various Crosspoint Control
System Links with Other Products
101.4
Multi-Format Support
Remote Control Units
Tally/name data
Main Features of MFR-5000
ON
480
37.5
OFF
Ethernet
RJ-45
2
4
Serial
9 pin D-sub (male)
1
1
Alarm output
9 pin D-sub (female)
1
1
ARCNET
BNC
2
2
401.7
Provides an interface for GPI control. This 1 RU sized unit is equipped with user-assignable GPI/O (128 channels) and 4 serial ports (9-pin D-sub male). It can be used for setting Input/Output and supports system configuration.
MFR-TALM is a device for performing central management of tally and material names of the MFR main unit and peripheral devices (such as video switchers and multi viewers). In the tally linking system like the one shown to the right (Fig. 1), MFR-TALM performs the tally calculation, which were originally performed by the MFR main unit, so that the tally linking can be speeded up.
1
DC12V IN
MFR-GPI External Dimensions
MFR-TALM External Dimensions
2.3
430 GPI UNIT
161
211 POWER
SERIAL
1
2
3
4
BUSY
SERIAL GPI
1
2
3
4
MFR-GPI
32 44
With redundant CPU installed
RESET
MFR-TALM TALLT MANAGER UNIT 1
PC-LAN
MFR-LAN
REF IN
DC12V IN
44
Standard configuration
2
RATING LABEL
SERIAL
2
POWER
BUSY
REF IN
GPI
1
2
3
4
RESET
480
110
GPI SERVICE
SER. No.
28
▲ MFR-TALM Rear Panel
105
28
21
170
▲ MFR-TALM External Dimensions
21
1
2
SERIAL
3
4
3.6
Connector
44
MFR-LAN SERVICE
429 462 480
MFR-LAN
GPI 1
GPI 2
RATING LABEL
GPI 3
GPI 4
2 - DC12V IN - 1
1 U compact type 16 buttons: lights in green only Any function can be assigned to the16 buttons Equipped with a display showing status and setting menu display
SNMP Support
Outstanding Maintainability
Designed for maintainability, all boards and power units can be accessed from the front without removing cables.
MFR-39RU
MFR-GPI MFR-16RU
MFR-40RU
■ ■ ■ ■
1 U compact type 40 buttons: light in 3 colors (red/green/orange) Any function can be assigned to any button Power source redundant (AC adapter)
MFR-40RU
DVI
DVI
RS-422 1/2/3/4 REF-IN
■ 2 U type ■ 39 buttons: 13 buttons in 3 rows. Buttons with LCD display that can show source names or assigned functions (7-color: red/green/yellow/blue/white/cyan/magenta) ■ Apart from the main buttons, there are 10 function buttons that can be freely assigned (Light in 3 colors: red/green/orange) ■ Equipped with display showing status and setting menu display ■ Ideal as a main control unit covering the entire crosspoint set-up ■ Power source redundant (AC adapter)
PREV monitor
Video Switcher HVS-4000
MV monitor 1
MFR-LAN
PC-LAN
MFR-18RU
MV monitor 2 Multi Viewer MV-3200
DVI
MV monitor 3 DVI
MFR-TALM MFR-39RU
Ethernet Hub
Ethernet Hub
MV monitor 4
GUI
MFR-5000 Rear Panel
MFR-16RU/16RUD/40RU/18RU External Dimensions 430
Supports Combinations of Multiple Remote Control Units
Multiple remote control units can be combined to make them function as a large scale control panel. Combination example: ■ For 128 × 128 full control + system settings: MFR-40RU × 4 + MFR-39RU × 1
2
3
4
(CPU2)
(CPU2)
PC-LAN
1
REF IN
2
IN 1
IN
3
4
1
IN 1
IN
5
1
6
IN 7
1
IN 1
8
OUT 1
1
OUT 1
OUT
2
1
3
OUT 1
4
OUT 1
5
OUT 6
1
OUT 1
7
8
SETUP
LOCK
RESET
PAGE
▲ MFR-16RU
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1
2
3
4
5
6
7
8
3G/HD/SD-SDI OUTPUT 1
2
3
4
5
6
7
BUSY
SETUP
LOCK
RESET
8
8
8
8
8
8
8
8
8
8
8
8
8
8
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
11
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
CANCEL
MFR-16RUD
REMOTE CONTROL UNIT
34
480
▲ MFR-16RUD MFR-LAN
RATING LABEL
8
8
9
ENTER
PAGE
8
DC12V IN
10
LOCK POWER
SLOT
OUT
BUSY
OUT 1
3G/HD/SD-SDI INPUT
IN
2
2
IN 1
REMOTE CONTROL UNIT
POWER
(CPU1) SERIAL
ARCNET
1 1
IN
MFR-16RU
LOCK (CPU1)
ALARM
IN OUT SYSTEM SETTING
2.3
MFR-LAN
MONITOR OUT (SDI)
32 44
1
▲ MFR-16RU/16RUD Rear Panel
430
2.3 REMOTE CONTROL UNIT
MFR-40RU
POWER
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
BUSY
SETUP
LOCK
RESET
▲ MFR-40RU 1
2
MFR-18RU
REMOTE CONTROL UNIT
Interface Expansion Unit
AC100-240V 50/60Hz IN
Remote monitoring by SNMP is supported and the router can easily be integrated into an SNMP monitoring system. In this way you can monitor the status of various items including: power source, fan, CPU, presence/absence of signals, crosspoint errors and more.
Routing Switcher MFR-5000 128 × 128
MFR-16RUD
One routing switcher can be virtually partitioned to build any theoretical hierarchy, creating possibilities for use in various operations. Examples: ■ Fully independent switching: a single unit can be used as multiple routing switchers by making multiple matrix partitions. This is effective when you wish to do multiple operations while avoiding source sharing. ■ V/Key linking switcher: allows two inputs to be linked for routing of video and key signals together. ■ 3D switcher: partition the matrix in two and control the left and right channels from a 3D source simultaneously. ■ HD/SD simul-switcher: provides simultaneous control of HD and SD sources. Perfect feature for HD/SD master control switching.
MFR-LAN
AC100-240V 50/60Hz IN
Redundancy Features ■ CPU board redundancy (option): a secondary CPU board constantly monitors the operation of the primary board. If the secondary CPU board detects any faults, operation is immediately switched to the secondary CPU to allow for continuous operation without down time. ■ Redundant power supply (option): in the rare event of a power supply problem, the second supply takes over to avoid any interruption of router function. ■ Network redundancy (option): a secondary Ethernet connection provides back-up for system control. With CPU redundancy, each interface can also have a backup (for details see below). ■ Direct control of main unit: the main unit has an LED display on the front. It can display settings and alarms.
■ ■ ■ ■
SDI
PC-LAN
32 44
Since routing switchers are the core of large video systems, we have engineered a variety of features to ensure full redundancy.
MFR-16RUD
PGM monitor
SDI
■ 1 U compact type ■ 18 buttons: light in 3 colors (red/green/orange) ■ Equipped with LCD display that can show source name and assigned functions for each button (7-color: red/green/yellow/blue/white/cyan/magenta) ■ Any function can be assigned to any button ■ Power source redundant (AC adapter)
32 44
Outstanding Redundancy
■ 1 U compact type ■ 16 buttons: light in green only ■ Any function can be assigned to the16 buttons
POWER
BUSY
SETUP
LOCK
RESET
32 44
The input/output board has 16 channels and up to 8 boards can be installed together. As a result, matrices of up to 128 input/128 output can be configured.
REF-TH
MFR-5000 External Dimensions
42
480
▲ MFR-18RU MFR-LAN
2
SERVICE
t2.3
RATING LABEL CPU 1
The interface expansion unit lineup includes two types to suit your specific application. The number of units that can be connected is a maximum of 128, including the remote control units.
CPU 2
MESSAGE/MENU
ALARM
ACTIVE
MESSAGE/MENU
ALARM
ACTIVE
1
DC12V IN
▲ MFR-40RU/18RU Rear Panel
MFR-39RU External Dimensions 430
2.3
POWER 1
ON
REMOTE CONTROL UNIT
OFF
MFR-GPI: GPI Unit
MFR-TALM: Tally Manager
ROUTING SWITCHER
MFR-5000
MFR-39RU
POWER
BUSY
LOCK
SETUP
CANCEL
RESET
POWER 2
Interface details
76 88
Configuring Matrices (up to 128 Input/128 Output)
Matrix Partition Function
From System
REF-IN
Tally/name data
Audio input/output card ■ MFR-16AESI (to be released in spring 2013): Input card for 16 stereo-pair (32 channels) AES/EBU ■ MFR-16ADI: Input card with processing function for 16 stereo-pair (32 channels) AES/EBU ■ MFR-16AESO (to be released in spring 2013): Output card for 16 stereo-pair (32 channels) AES/EBU ■ MFR-16ADAO: Output card enables support for 2 SDI embedded audio, 8 stereo-pair (16 channels) AES/EBU and 8ch analog audio. ■ MFR-16AAI: (to be supported in the future) Input card supported for 32 channels analog audio.
SDI
Name information
Audio input and output cards are available for the MFR-5000 in addition to video I/O cards. This allows for a combined audio/video router in a single cabinet along with A/D and D/A conversion, plus embedding and de-embedding operations.
MFR-18RU
Tally data
Various Audio Input and Output Support
MFR-16RU
37.4
■ Salvo function (1) Button-assigned Salvo: multiple crosspoints can be assigned to any button. Separate settings can be made for each remote unit. (2) Main unit storage Salvo: multiple crosspoints can be stored on the main unit side and shared by all remote units. ■ Take operation: after presetting crosspoints, press the Take button to change the set crosspoints. (1) Mode-switching Take button: switches between take operation and usual operation (instant execution). (2) Always Take button: always performs take. ■ Link function: this can group and link multiple crosspoints. ■ Level operation: level switching allows separate control over different subject types. ■ Chop function: allows user to switch between two sources for a destination. ■ Monitor out: enables output of any destination source to a dedicated monitoring channel. ■ Prevention of incorrect operation: - Inhibit: Crosspoint, Source, Destination - Lock: Lock Other / Lock All / Lock Local
A variety crosspoint control features are possible in addition to normal crosspoint switching.
The MFR-5000 enables tally linking with FOR-A’s video switcher HANABI Series and multi viewer MV Series. And when switching between sources on the MFR-5000 side, the source name displayed by the video switcher or multi viewer can also change automatically. It supports TSL and Harris protocol, enabling linkage with 3rd party equipment.
101.5
Video input/output card ■ MFR-16SDI: 16-input card enables support for 3G/HD/SD-SDI and ASI ■ MFR-16SDO: 16-output card enables support for 3G/HD/SD-SDI and ASI
Input and output support for: 3G-SDI, HD-SDI, SD-SDI and ASI, with automatic detection of signal type.
We offer several types or remote control to suit your application. The number of units that can be connected is a maximum of 128, including the main unit. This lets you build a flexible control environment by the way you partition the matrix and make operation level settings.
76.2 354
Various Crosspoint Control
System Links with Other Products
101.4
Multi-Format Support
Remote Control Units
Tally/name data
Main Features of MFR-5000
ON
480
37.5
OFF
Ethernet
RJ-45
2
4
Serial
9 pin D-sub (male)
1
1
Alarm output
9 pin D-sub (female)
1
1
ARCNET
BNC
2
2
401.7
Provides an interface for GPI control. This 1 RU sized unit is equipped with user-assignable GPI/O (128 channels) and 4 serial ports (9-pin D-sub male). It can be used for setting Input/Output and supports system configuration.
MFR-TALM is a device for performing central management of tally and material names of the MFR main unit and peripheral devices (such as video switchers and multi viewers). In the tally linking system like the one shown to the right (Fig. 1), MFR-TALM performs the tally calculation, which were originally performed by the MFR main unit, so that the tally linking can be speeded up.
1
DC12V IN
MFR-GPI External Dimensions
MFR-TALM External Dimensions
2.3
430 GPI UNIT
161
211 POWER
SERIAL
1
2
3
4
BUSY
SERIAL GPI
1
2
3
4
MFR-GPI
32 44
With redundant CPU installed
RESET
MFR-TALM TALLT MANAGER UNIT 1
PC-LAN
MFR-LAN
REF IN
DC12V IN
44
Standard configuration
2
RATING LABEL
SERIAL
2
POWER
BUSY
REF IN
GPI
1
2
3
4
RESET
480
110
GPI SERVICE
SER. No.
28
▲ MFR-TALM Rear Panel
105
28
21
170
▲ MFR-TALM External Dimensions
21
1
2
SERIAL
3
4
3.6
Connector
44
MFR-LAN SERVICE
429 462 480
MFR-LAN
GPI 1
GPI 2
RATING LABEL
GPI 3
GPI 4
2 - DC12V IN - 1
3G/HD/SD/ASI/Routing Switcher
MFR-5000
3G/HD/SD/ASI/AES/Routing Switcher The MFR-5000 Series is a group of multi-format routing switchers supporting 3G-SDI, HD-SDI, SD-SDI, ASI and AES. Inside the 8 U case a matrix of up to 128 inputs/128 outputs can be configured. It offers expansive flexibility at the core of your system, such as tally connections with peripheral devices (video switchers and multi viewers) and automatic source name tracking. MFR-5000 Systems Specifications ● Video formats
3G HD: 1080/60p, 1080/59.94p, 1080/50p HD: 1080/60i, 1080/59.94i, 1080/50i, 1080/30p, 1080/30PsF, 1080/29.97p, 1080/29.97PsF, 1080/23.98p, 1080/23.98Psf, 1080/25p, 1080/25PsF, 1080/24PsF, 1080/24p, 720/60p, 720/59.94p, 720/50p SD: 525/60, 625/50 Min. 64 × 64 - Max. 128 × 128 + 4 monitoring outputs (Can be expanded in increments of 16 channels) Compliant with the following (75Ω, BNC) · SMPTE424M (3 Gbps) · SMPTE292M (1.5 Gbps) · SMPTE259M (270 Mbps) · DVB-ASI 3G/HD-SDI: 100 m (5C-FB or equivalent) SD-SDI: 200 m (5C-2V or equivalent) Compliant with the following (75Ω, BNC) (Auto reclocking) · SMPTE424M (3Gbps) · SMPTE292M (1.5 Gbps) · SMPTE259M (270 Mbps) · DVB-ASI 3G/HD/SD-SDI, DVB-ASI: 75Ω BNC × 4 (Auto reclocking not supported) AES/EBU · BNC × 16 (Stereo × 16) · Sampling Frequency: 32 kHz, 44.1 kHz, 48 kHz, 96 kHz AES/EBU (Only synchronized audio) · BNC × 8 (Stereo × 8) · Sampling Frequency: 48 kHz Embedded audio · BNC × 2 (Stereo × 8) · Sampling Frequency: 48 kHz Analog audio · 25-pin D-sub (female) (Stereo × 4) balanced or unbalanced · Output impedance: less than 100Ω · Sampling Frequency: 48 kHz
● Input × Output ● Video Inputs MFR-16SDI
● Cable Equalization ● Video Outputs MFR-16SDO
● Monitoring Outputs ● Audio Inputs MFR-16ADI ● Audio Outputs MFR-16ADAO
● Reference Inputs ● Interfaces ◆MFR-LAN:
◆PC-LAN: ◆ARCNET ◆SERIAL ◆ALARM ● Temperature / Humidity ● Power ● Consumption
● Dimensions / Weight ● Accessories ● Options
BB: NTSC: 0.429 Vp-p/PAL: 0.45 Vp-p or Tri-level Sync: ±0.3 Vp-p 75Ω, BNC × 2, Loop through (Terminate with 75Ω terminator, when unused)
Remote Control Unit Specifications ● Model Name ● Buttons/Colors
MFR-16RU 16 buttons (1 color only: green) user assignable
MFR-16RUD 16 buttons (1 color only: green) user assignable
3G/HD/SD/ASI/AES Routing Switcher
MFR-5000
10/100/1000 Base-T, RJ-45 × 2 (for connecting the RU/GPI unit. Up to 128 units can be connected) (The second LAN port is used in the redundant CPU configuration) 10/100 Base-TX, RJ-45 × 2 (for PC operation) (The second LAN port is used in the redundant CPU configuration) 10Mbps 75Ω or Loop through, BNC × 2 (Terminate with 75Ω terminator, when unused) (for video switcher HANABI series) RS-232C/RS-422 (Internal switch), 9-pin D-sub (male) × 1 9-pin D-sub (female) × 1 (Input: Reset /Output: Power, Fan Alarm) 0ºC - 40ºC / 30% - 85% (no condensation) 100 V AC - 240 V AC ±10%, 50/60Hz × 2 128 × 128, Dual CPU/Redundant Power Unit (Maximum Configuration): 390 VA at 100 V AC, 462 VA at 240 V AC 480 (W) × 354 (H) × 402.7 (D) mm; EIA 8 RU / Approx. 50 kg (Full option) Operation manual, AC cord, Rack mount bracket, AC cord retaining clip MFR-16RU: Remote Control Unit (16 buttons) MFR-16RUD: Remote Control Unit (16 buttons, LCD display) MFR-40RU: Remote Control Unit (40 buttons) MFR-18RU: Remote Control Unit (18 buttons, LCD display) MFR-39RU: Remote Control Unit (LCD 39 buttons, 10 buttons, menu display) MFR-GPI: GPI unit MFR-TALM: Tally manager MFR-CPU: Redundant CPU Card MFR-PS: Redundant Power Supply Unit MFR-16SDI: Digital Video Input Card MFR-16SDO: Digital Video Output Card MFR-16ADI: Digital Audio Input Card with Processing Function MFR-16ADAO: Digital Audio Output Card with Processing Function MFR-16AAI: Analog Audio Input Card MFR-16AESI: Digital Audio Input Card MFR-16AESO: Digital Audio Output Card
MFR-5000
MFR-GPI Specifications MFR-40RU 40 buttons (3-color: red/green/orange) user assignable
● Name Display
None
None
● Menu Display
None
● Rotary selector ● Number of Connections ● Interfaces ◆MFR-LAN: ◆SERVICE: ● Power ●Consumption ◆when AC 100V ◆when AC 240V ● Dimensions ● Weight ● Accessories
None Max. 128 units
Available None (Max. 16 characters × 2 lines) None None
None
MFR-18RU 18 buttons (3-color: red/green/orange) user assignable
MFR-39RU 39 buttons (LCD buttons, 7-color) user assignable 10 buttons (3-color: red/green/orange) user assignable Available (Displayed above Available (Displayed in each each button) button) LCD display × 18 LCD display × 39 (Max. 7 characters × 2 lines) (Max. 7 characters × 2 lines) Available None (Max. 23 characters × 2 lines) Available Available
10/100 Base-TX RJ-45 × 1 (for connection to MU; network hub required for connecting to multiple MUs) None RS-232C 9-pin D-sub (male) × 1 (for maintenance) None +12 VDC Pin-connector × 1 +12 VDC Pin-connector × 2 (redundant power supply as standard)
● Interfaces ◆GPI IN/TALLY OUT ◆Expand I/F
● Power ● Consumption ● Dimensions ● Weight ● Accessories
MFR-TALM Specifications ● Interfaces ◆MFR-LAN ◆PC-LAN ◆SERIAL ◆GPI IN/OUT
7VA 10VA 7VA 11VA 15VA 11VA 430 × 44 × 34 mm 430 × 44 × 42 mm 430 × 44 × 34 mm 1 kg 1 kg 2 kg AC adapter × 1, AC adapter connection kit × 1, rack mount bracket, LAN cable
12VA 18VA 430 × 44 × 42 mm 2 kg
17VA 22VA 430 × 88 × 44 mm 3 kg
37-pin D-sub (female) × 4 128 input/output (I/O composition is optional) RS-232C/422: 9-pin D-sub (male) × 4 See the Remote Control Unit Specifications. 17 VA (when 100 V AC), 22 VA (when 240 V AC) 430 (W) × 44 (H) × 110 (D) mm 2 kg See the Remote Control Unit Specifications.
◆REF IN ● Power ● Consumption ● Dimensions ● Weight ● Accessories
10/100/1000 Base-T RJ-45 × 1 (For connecting to the main unit) 10/100 Base-TX RJ-45 × 1 (For connecting a PC or external device) RS-422: 9-pin D-sub (male) × 4 37-pin D-sub (female) × 1 (GPI connector for external control) BB or Tri-level Sync, BNC × 1 See the Remote Control Unit Specifications. 17 VA (when 100 V AC), 20 VA (when 240 V AC) 212 (W) × 44 (H) × 161 (D) mm 2 kg See the Remote Control Unit Specifications.
FOR-A COMPANY LIMITED
URL: http://www.for-a.com/
Head Office: 3-8-1 Ebisu, Shibuya-ku, Tokyo 150-0013, Japan Tel : +81 (0)3-3446-3936 FOR-A Corporation of America: 11155 Knott Ave., Suite G&H, Cypress, CA 90630, U.S.A. Tel: +1-714-894-3311 FOR-A Corporation of America East Coast Office: 2 Executive Drive, Suite 670, Fort Lee Executive Park, Fort Lee NJ 07024, U.S.A. Tel: +1-201-944-1120 FOR-A Corporation of America Distribution & Service Center: 2400 N.E. Waldo Road, Gainesville, FL 32609, U.S.A. Tel: +1-352-371-1505 FOR-A Corporation of America Miami Office: 5200 Blue Lagoon Drive, Suite 760, Miami, FL 33126, U.S.A. Tel: +1-305-931-1700 FOR-A Corporation of Canada: 346A Queen Street West, Toronto, Ontario M5V 2A2, CANADA Tel: +1-416-977-0343 FOR-A UK Limited: Unit C71, Barwell Business Park, Leatherhead Road, Chessington Surrey, KT9 2NY, UK Tel: +44 (0)20-8391-7979 FOR-A Italia S.r.l.: Via Volturno, 37, 20047, Brugherio MB, Italy Tel: +39-039-881-086/103 FOR-A Corporation of Korea: 1007, 57-5,Yangsan-ro,Yeongdeungpo-gu, Seoul 150-103, Korea Tel: +82 (0)2-2637-0761 FOR-A China Limited: 708B Huateng Building, No. 302, 3 District, Jinsong, Chaoyang, Beijing 100021, China Tel: +86 (0)10-8721-6023 FOR-A Middle East-Africa Office: Jebel Ali Free Zone, LOB-16, Office 619, P.O. Box 261914, Dubai, U.A.E. Tel: +971 4 887 6712
Fax : +81 (0)3-3446-1470 Fax: +1-714-894-5399 Fax: +1-201-944-1132 Fax: +1-352-378-5320 Fax: +1-305-264-7890 Fax: +1-416-977-0657 Fax: +44 (0)20-8391-7978 Fax: +39-039-878-140 Fax: +82 (0)2-2637-0760 Fax: +86 (0)10-8721-6033 Fax: +971 4 887 6713
ISO 9001 and 14001 certified (Sakura R&D) © 2013 FOR-A Company Ltd. FOR-A is a registered trademark of FOR-A Company Ltd. Design and specifications subject to change without notice. Printed in Japan. 1301FJ2C