Transcript

! WARNING: Do Not operate with Power connected. 2. Structure and Function (1) If a registered user verified, the device will trigger TCP/IP the lock control relay to open the door. Note:This device works standalone or networked. ZK Access3.5 software is ④ required for networdked management. ① ② SEN DC12V GND BUT the door is unexpectedly opened or improperly closed, Exit Switch NC LOCK - the alarm relay will be triggered. FR 107 + Lock Sensor (3) If the device is illegally removed, the alarm relay will be triggered. GND SEN DC12V GND NO LOCK + COM1 BUT FR 107 NO1 COM1 NC1 NC1 NO2 NO2 COM2 COM2 Device share power with the lock: ULOCK=12V, I-ILOCK>1A......1); And the distance between the lock and the device is ≤10 meters. Baseline (4) External exit button is supported. 1.1M recommended height from the ground can be adjusted according to the staff height. +12V - NO1 Mounting Paper(only for your reference) Cable hole + +12V GND (2) The door sensor will detect the ON-OFF state. If Exit 1. Equipment installation - + ⑤ - Version: 1.1 Date: Jan. 2014 1) Share power with the lock: + + Access Control System Function - Access Control Color Screen RFID Series Product Installation Guide 2) Does not share power with the lock: (5) Supports TCP/IP communication to be able to connect ③ (1) Paste the mounting template on (2) Remove the screws on (3) Take away the back plate. the wall. Drill the holes according the bottom of device. to the marks on the template (holes for screws and wiring). with a PC. One PC can manage multiple devices. + + +12V +12V DC12V- GND - GND DC12V + Alarm - SEN DC Power- (1) The system supports NO lock and NC lock. For example the NO lock (normally open at power on) Alarm Power NO1 NC1 + COM2 +12V - + GND 7. Wiegand Input (4) Keep the exposed part of wire less than 5mm, to avoid unexpected connection. +12V GND DATA0 DATA1 +12V GND GND IND0 IND0 IND1 IND1 WD0 WD0 WD1 WD1 (5) Please connect the 'GND' when starting installations, especially in an environment where static electricity is very high. 9. Communication The device has a Wiegand input port, which enables the connection to a slave card reader. Devices are control devices on both sides of the door to control the access and electric lock. 3 (3) Please read the terminal and wiring description and diagrams carefully before commencing with installations. Any damage to the device caused by improper operations, will not be covered under warranty. If the device is being illegally removed, the button loses connectivity and will trigger the alarm. Reset Button Tamper Button The device supports standard Wiegand 26-bit output, so you can connect it with various access control devices. Access Control Panel D. We suggest user does not share power with the lock. 1): ‘I’: device output current, ‘ULOCK’: lock voltage,‘ILOCK’: lock current. (2) We recommend use the DC 12V/3A power supply. Please contact our technical staff for details. Alarm Voltage output ≤ DC 12V 6. Wiegand Output COM2 (1) Connect the power cable after all the wiring has been completed. If the device is working abnormally, please shut down the device, and make necessary checks. Please note that any "HOT SWOP" of wiring on the device may damage the device, and the warranty does not cover damage caused by improper operations. (2)Tamper Alarm Function: DC12V NC1 NO2 10. Caution Back View Reset - Side View Operation: Remove the black rubber cap, then stick the Reset button hole with a sharp tool (the tip diameter is less than 2mm). Door Sensor DC Power ! WARNING: Do Not operate with Power connected. If the device does not work properly because of misoperation or other abnormality, you can use ‘Reset’ function to restart it. COM1 NO2 Alarm 2 (1) Manual Reset: Positive is connected with‘+12V’; negative is connect with ‘GND’ (do not reverse the polarities). BUT + GND the system. NB: Do not reverse the polarities! 8. Other Functions & Features The device 5. Power working Connection: voltage DC 12V, electric current 500mA (50mA for standby current). SEN Exit Button 1 + A. ULOCK=12V, I-ILOCK≤1A; B. ULOCK≠12V; C. The distance between the lock and the device is >10 meters. (shipped in package) in parallel with the connection to prevent self-inductance EMF feedback 5. Power Connection 4. Other Connections Exit tighten the screws at the bottom of the unit. COM2 NO1 COM1 Device does not share power with the lock: (2) When the electrical lock is connected to the Access Control System, you need to connect one FR107 diode according to the mounting paper. - NC LOCK COM1 NO2 SEN GND BUT - NC1 FR 107 "COM" terminals. (5) Place the unit onto the mounting bracket, and + FR 107 + NO LOCK NO1 - is connected with "NO" and "COM" terminals, and the NC lock is connected with "NC" and (4) Fix the back plate on the wall GND BUT 3.Lock Connection - + (6) Do not change the cable type in case of a long distance installations. TCP/IP Mode: Two ways for TCP/IP connection. (A) Crossover cable: The device and PC connected directly. (B) Straight cable: The device and PC connected to LAN/WAN through switch/Lanswitch. * Reserves the final rights of modification and interpretation. +12V Switch GND DATA0 … DATA1 Reader Access Control Device Access Control Device (1) Don’t exceed 90m (meters) distance between the Device and Access Control Lock or Card Reader. (In the case of long distance installation, use the Wiegand Signal Extender, to minimise interference.) (2) To keep a balanced and stable Wiegand signal, connect the device, access control lock or card reader on the same “GND” (ground) port. IP Address:192.168.1.124 Subnet Mask:255.255.255.0 IP Address:192.168.1.201 Subnet Mask:255.255.255.0 4 5 6