Pds Series Rackmount Power Sequencer

   EMBED


Share

Transcript

96-940/ rev 3c / 12-19-12 PDS Series Rackmount Power Sequencer EIA/TIA Compliant EXCEPTIONAL SUPPORT & PROTECTION™ Rackmount Power Sequencer provides sequenced 15 amp (single or dual circuit) and 20 amp (single circuit) power PDS-615R Features front view • Provides 6-step sequencing to six rear outlets • Single 15 or 20 amp circuit or dual 15 amp circuit models available rear view • Adjustable start delay times PDS-620R • Adjustable sequence intervals front view • System may be activated locally via front panel, or remotely via rear terminal block • Up to three units may be chained together via simple parallel wiring, providing 18 sequence steps • UL Listed in the US and Canada rear view PDS-2X315R front view rear view EIA compliant 19” rackmount power sequencer shall be Middle Atlantic Products model # PDS-__(refer to chart)R and shall be constructed of 16-gauge steel finished in durable black powder coat. Power sequencer shall operate on 115 volt AC/60Hz power and shall terminate with (1,2) 9' 3 wire SignalSafe™ power cord(s) with NEMA 5-__(15,20)P plug(s)(refer to chart). Rear, dry contact closure shall provide status indication to compatible customer supplied monitoring device. Contacts shall be closed when all channels are on; contacts shall be open when all channels are closed. Power sequencer shall feature __ circuits (refer to chart). Power sequencer shall feature (15,20) amp circuitry for six rear-mounted NEMA 5-__(15,20)R receptacles and a (15,20) amp front-mounted circuit breaker(s) and master switch. Additional (15, 20) amp rear outlet shall be unswitched and uncontrolled. Power Sequencer shall be ETL listed to UL standard 1419, UL 60950-1 and UL 60065 in the US; CSA standard 60950-1, and CSA C22.2 No. 60065 in Canada. Power sequencer shall comply with the requirements of RoHS EU Directive 2001/95/EC. Power sequencer shall be GREENGUARD Indoor Air Quality Certified for Children and Schools. Power sequencer shall be manufactured by an ISO 9001 and 14001 registered company. Power sequencer shall be warrantied to be free from defects in material or workmanship under normal use and conditions for a period of 3 years. C U S T O M I Z A B L E S P E C I F I C AT I O N C L I P S AVA I L A B L E AT M I D D L E AT L A N T I C . C O M US: New Jersey • California • Illinois • Voice: 973-839-1011 Fax: 973-839-1976 • middleatlantic.com Canada: Ontario • British Columbia • Voice: 613-836-2501 Fax: 613-836-2690 • middleatlantic.ca 96-940 / rev 3c / 12-19-12 / 115 Volt Rackmount Power Strips Architects’ and Engineers’ Specifications PDS Series basic dimensions and settings Middle Atlantic Products PDS-615R shown top view front view rear view Maximum Derated Load (North America) for 15 Amp Models: 12 Amps for 20 Amp Models: 16 Amps Model # PDS-615R Cord # of Circuits Outlet Type Termination One 15 amp NEMA 5-15R One NEMA 5-15P PDS-620R One 20 amp NEMA 5-20R One NEMA 5-20P PDS-2X315R Two 15 amp NEMA 5-15R Two NEMA 5-15P sequencer #1 Dip Switch Settings up com down DELAY BETWEEN SEQUENCES SEQUENCE UP/DOWN START DELAY If 2 or 3 sequencers are to be used (“chained”) together: sequencer #1 first on .75 second interval between each outlet power up/down 1.5 second interval between each outlet power up/down 2.25 second interval between each outlet power up/down 7 second interval between each outlet power up/down 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 last off sequencer #2 1 2 3 4 up com down sequencer #2 second on second off 1. Wire all rear terminal blocks in parallel. last on 2 . Front System Power UP/DOWN switch is wired in parallel with rear remote terminal block. When wired together as shown, pressing front System Power UP/DOWN switch on ANY sequencer will initiate system sequencing. 1 2 3 4 sequencer #3 first off 1 2 3 4 3. If remote Power UP/DOWN is required, wire dry contacts in parallel. sequencer #3 4. Initiating system sequencing remotely: Sequencing can be initiated by either momentary dry contact or maintained dry contact. Use of a maintained dry contact for system power up will re-initiate sequence after power is restored from a power outage. When using maintained (non-momentary) dry contact for remotely controlling system sequencing, the front System Power UP/DOWN switches will be over-ridden. up com down NOTE: A flashing power (green) LED indicates system sequencing has begun. ALL DIMENSIONS IN INCHES [Bracketed dimensions in millimeters] US: New Jersey • California • Illinois • Voice: 973-839-1011 Fax: 973-839-1976 • middleatlantic.com Canada: Ontario • British Columbia • Voice: 613-836-2501 Fax: 613-836-2690 • middleatlantic.ca