Transcript
PDUBV24-S30-200+ February 2010 MT1000A-85-R4
30-Amp Vertical PDU, 24-Outlet (IEC C13 [2x12])
Plenty of outlets in zero-U of rack space.
BLACK BOX
Vertical mounting puts 24 200–250 VAC outlets where you need them.
®
Specifications Circuit Breaker: (2) 15A pole Cord Connector: L6-30P
Overview
Cord Length: 10 ft. (3 m) Cord Type: SJT 10/3C
This 30-amp, vertically mounted power distribution unit features 24 outlets.
Current Alarm: No Current Rating: 30 A (24 A derated) Input Voltage: 200–250 VAC Metered: No
What’s included
Mounting: Vertical, 0U
• 24-outlet vertical PDU
Number of Outlets: 24
• (2) mounting brackets
Outlet Type: IEC C13 (2 x 12)
• (8) bracket-mounting screws
Outlet Location: Front
• Manual
RoHS: Yes Indicators: (2) Power LED Customer Support Information
For installation and safety instructions, turn the page… Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail:
[email protected]
30-Amp Vertical PDU, 24-Outlet (IEC C13 [2x12])
Installation Steps 1. Attach the vertical mounting brackets to the PDU with the supplied screws. 2. This PDU is designed for indoor usage and should be mounted vertically into a standard EIA 19” equipment rack. The unit should be attached via mounting brackets behind, beside, or on the vertical rails with proper screws. Placement of the PDU is dependent upon customer preference. Warning: Failure to properly ground this PDU by not tightening the rack screw fasteners or fully inserting the PDU into the equipment rack can create a hazardous condition to the installer and to the equipment. 3. Attach the equipment loads into the matching receptacles. The total combined load must be less than that specified on the label. Warning: Prior to connecting input power cables, ensure that the circuit breaker is turned off and that the input power to the PDU is turned off. 4. Attach the power source to the input receptacle(s) on the PDU. 5. If the PDU is equipped with LEDs, verify that the LED indicator lamps illuminate. Warning: Elevated Operating Ambient Temperature: If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. When installing equipment, be sure to consider the ambient temperature range of 32 to 77° F (0 to 25° C), or 32 to 131° F (0 to +55° C) for non-metered units. Reduced Airflow — Installation of the equipment in a rack should be such that the amount of airflow required for safe operation of the equipment is not compromised. Mechanical Loading — Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. Circuit Overloading — Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. For North American permissible loads, refer to Article 210.23 of the National Electric Code. Reliable grounding of rackmounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit. - Output connector voltage rating is 200–250V ~ - Maximum current rating is located on the product label.
Page 2
724-746-5500 | blackbox.com
30-Amp Vertical PDU, 24-Outlet (IEC C13 [2x12])
Safety Instructions Before installation, read these instructions carefully and completely. These installation instructions cannot cover every possible installation, operation, or maintenance situation. Further information can be obtained from the product data sheets, which can be obtained from Black Box Corporation. This Power Distribution Unit (PDU) is constructed and approved in accordance with the safety requirements of IEC/EN60950 and FCC emission standards. Warning: Never work on the PDU if power is applied. Before any installation, maintenance, or modification work, ensure that the power source is switched off and properly secured to remain off. Touching any live components or improper handling of this PDU can result in death, severe personal injury, or substantial damage to property. Safe operation is dependent upon proper storage, handling, installation, and operation. Compliance with the relevant national regulations in the U.S., Europe, or other countries must be ensured. Before operation is started, the following conditions must be observed: • Connections to main power supply must be made in compliance with national regulations (NEC, NEMA, VDE0100 and EN50178). • When using stranded wires, all strands must be fastened in the terminal blocks (to avoid the potential danger of contact with the enclosure). • The power supply and main cables must be sufficiently fused. • The degree of protection is I to IEC536. The non-fused protective ground connection must be connected to the Field Ground Terminal. • All output wires must be rated for the output current of the PDU, and must be connected with the correct polarity. • The main socket-outlet should be installed near the equipment and should be easily accessible.
Page 3
© Copyright 2010. Black Box Corporation. All rights reserved. Printed in U.S.A. Black Box® and the Double Diamond logo are registered trademarks of BB Technologies, Inc. Double Diamond™ is a trademark of BB Technologies, Inc. Any third-party trademarks appearing in this publication are acknowledged to be the property of their respective owners. PDUBV24-S30-200+, rev. 1
FREE, live, 24/7 Tech Support is just 30 seconds away. 724-746-5500 | blackbox.com