Preview only show first 10 pages with watermark. For full document please download

Pffy-p-vlrmm

   EMBED


Share

Transcript

10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx 25/4/08 15:16 Page 1 Floor standing R410A Data PFFY-P-VKM-E G4 PFFY-P-VKM-E PFFY-P-VLEM-E PFFY-P-VLRM-E PFFY-P-VLRMM-E PFFY-P-VLEM-E A B C D PFFY-P-VLRM-E PFFY-P-VLRMM-E E F 1. SPECIFICATIONS IU-H- 2 2. EXTERNAL DIMENSIONS IU-H- 8 G 3. ELECTRICAL WIRING DIAGRAMS IU-H- 12 H 4. SOUND LEVELS 4-1. Sound levels 4-2. NC curves 4-3. Fan characteristics curves IU-H- 15 IU-H- 15 IU-H- 18 V-A 5. TEMPERATURE/AIRFLOW DISTRIBUTIONS 5-1. Temperature distributions 5-2. Airflow distributions IU-H- 21 IU-H- 22 BC V-B CT Floor standing P20 P25 P32 P40 P50 P63 P71 P80 P100 P125 P140 P200 P250 0.8HP 1.0HP 1.3HP 1.6HP 2.0HP 2.5HP 2.8HP 3.2HP 4.0HP 5.0HP 5.6HP 8.0HP 10.0HP PFFY-P-VKM-E PFFY-P-VLEM-E PFFY-P-VLRM-E PFFY-P-VLRMM-E PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E IU - H - 1 10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx 25/4/08 15:16 Page 2 1. SPECIFICATIONS R410A Data Model PFFY-P20VKM-E Power source Cooling capacity (Nominal) ✻1 ✻1 ✻1 ✻2 Power input Current input ✻3 Heating capacity (Nominal ) ✻3 ✻3 A B C D E F G H V-A V-B BC CT Power input Current input External finish External dimension H x W x D Net weight Heat exchanger FAN Type x Quantity External static press. Motor type Motor output Driving mechanism Airflow rate (Low-Mid-High -SHigh) Noise level (Low-Mid-High-SHigh) (measured in anechoic room) Insulation material Air filter Protection device Refrigerant control device Connectable outdoor unit Liquid Diameter of (R410A) refrigerant pipe (R22, R407C) Gas (R410A) (R22, R407C) Field drain pipe size External Drawing Wiring Refrigerant cycle Document Standard Accessory attachment Remark mm in. kg (lb) Pa mmH2O kW m3 / min L/s cfm dB Indoor : Outdoor : Pipe length : Level difference : 5.9 - 6.8 - 7.6 - 8.7 98 - 113 - 127 - 145 208 - 240 - 268 - 307 27 - 31 - 34 - 37 PFFY-P32VKM-E 1-phase 220-230-240V 50Hz 3.6 2.8 3,100 2,400 12,300 9,600 3,200 2,500 0.025 0.025 0.20 0.20 4.0 3.2 3,400 2,800 13,600 10,900 0.025 0.025 0.20 0.20 Plastic (Pure White) 600 x 700 x 200 23-5/8" x 27-9/16" x 7-7/8" 15 (34) Cross fin (Aluminium fin and copper tube) Line flow fan x 2 0 0 DC motor 0.03 x 2 Direct-drive 6.1 - 7.0 - 8.0 - 9.1 6.1 - 7.0 - 8.0 - 9.1 102 - 117 - 133 - 152 102 - 117 - 133 - 152 215 - 247 - 283 - 321 215 - 247 - 283 - 321 28 - 32 - 35 - 38 28 - 32 - 35 - 38 PFFY-P40VKM-E 4.5 3,900 15,400 4,000 0.028 0.24 5.0 4,300 17,100 0.028 0.24 8.0 - 9.0 - 9.5 - 10.7 133 - 150 - 158 - 178 283 - 318 - 335 - 378 35 - 38 - 42 - 44 Polyethylene sheet PP honeycomb fabric (Catechin air filter) Fuse LEV R410A, R407C, R22 CITY MULTI ø6.35 (ø1/4") Flare ø6.35 (ø1/4") Flare ø12.7 (ø1/2") Flare ø12.7 (ø1/2") Flare I.D. 16mm (5/8") IU-BK01-B517 IU-RG79-V367 Installation Manual, Instruction Book mm (in.) mm (in.) mm (in.) - Optional parts Installation Note : 2.2 1,900 7,500 2,000 0.025 0.20 2.5 2,200 8,500 0.025 0.20 kW kcal / h Btu / h kcal / h kW A kW kcal / h Btu / h kW A PFFY-P25VKM-E G4 Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual. ✻1 Nominal cooling conditions 27˚CDB/19˚CWB (81˚FDB/66˚FWB) 35˚CDB (95˚FDB) 7.5 m (24-9/16 ft) 0 m (0 ft) ✻2 Nominal cooling conditions 27˚CDB/19.5˚CWB (81˚FDB/67˚FWB) 35˚CDB (95˚FDB) 5 m (16-3/8 ft) 0 m (0 ft) ✻3 Nominal heating conditions 20˚CDB (68˚FDB) 7˚CDB/6˚CWB (45˚FDB/43˚FWB) 7.5 m (24-9/16 ft) 0 m (0 ft) * Nominal conditions ✻1, ✻3 are subject to JIS B8615-1. * Due to continuing improvement, above specification may be subject to change without notice. Unit converter kcal/h Btu/h cfm lb = kW x 860 = kW x 3,412 = m3/min x 35.31 = kg / 0.4536 *Above specification data is subject to rounding variation. Ref.: Spec_PFFY-P-VKM-E_1 PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E IU - H - 2 10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx 25/4/08 15:16 Page 3 1. SPECIFICATIONS R410A Data Model ✻1 ✻1 ✻1 ✻2 Power input Current input ✻3 Heating capacity (Nominal ) ✻3 ✻3 Power input Current input External finish External dimension H x W x D Net weight Heat exchanger FAN Type x Quantity External static press. Motor type Motor output Driving mechanism Airflow rate (Low-High) Noise level (Low-High) (measured in anechoic room) kW kcal / h Btu / h kcal / h kW A kW kcal / h Btu / h kW A 2.2 1,900 7,500 2,000 0.04 / 0.06 0.19 / 0.25 2.5 2,200 8,500 0.04 / 0.06 0.19 / 0.25 mm in. kg (lb) 630 x 1,050 x 220 24-13/16" x 41-3/8" x 8-11/16" 23 (51) Sirocco fan x 1 0 0 Pa mmH2O 0.015 kW 5.5 - 6.5 92 - 108 194 - 230 32 - 38 (220V, 50Hz) 33 - 39 (230V, 50Hz) 34 - 40 (240V, 50Hz) m3 / min L/s cfm dB dB dB Insulation material Air filter Protection device Refrigerant control device Connectable outdoor unit Liquid Diameter of (R410A) mm (in.) refrigerant pipe (R22, R407C) Gas (R410A) mm (in.) (R22, R407C) Field drain pipe size mm (in.) External Drawing Wiring Refrigerant cycle Document Standard Accessory attachment Remark Indoor : Outdoor : Pipe length : Level difference : ø6.35 (ø1/4") Flare ø6.35 (ø1/4") Flare ø12.7 (ø1/2") Flare ø12.7 (ø1/2") Flare PFFY-P32VLEM-E PFFY-P40VLEM-E 1-phase 220-240V 50Hz, 1-phase 208-230V 60Hz 2.8 3.6 4.5 2,400 3,100 3,900 9,600 12,300 15,400 2,500 3,150 4,000 0.04 / 0.06 0.06 / 0.07 0.065 / 0.075 0.19 / 0.25 0.29/0.30 0.32 / 0.33 3.2 4.0 5.0 2,800 3,400 4,300 10,900 13,600 17,100 0.04 / 0.06 0.06 / 0.07 0.065 / 0.075 0.19 / 0.25 0.29 / 0.30 0.32 / 0.33 Acrylic painted, MUNSELL (5Y 8/1) 630 x 1,050 x 220 630 x 1,170 x 220 630 x 1,170 x 220 24-13/16" x 41-3/8" x 8-11/16" 24-13/16" x 46-1/8" x 8-11/16" 24-13/16" x 46-1/8" x 8-11/16" 23 (51) 25 (56) 26 (58) Cross fin (Aluminium fin and copper tube) Sirocco fan x 1 Sirocco fan x 2 Sirocco fan x 2 0 0 0 0 0 0 1-phase induction motor 0.015 0.018 0.030 Direct-driven by motor 5.5 - 6.5 7.0 - 9.0 9.0 - 11.0 92 - 108 117 - 150 150 - 183 194 - 230 247 - 318 318 - 388 32 - 38 (220V, 50Hz) 33 - 38 (220V, 50Hz) 36 - 41 (220V, 50Hz) 33 - 39 (230V, 50Hz) 34 - 39 (230V, 50Hz) 37 - 42 (230V, 50Hz) 34 - 40 (240V, 50Hz) 35 - 40 (240V, 50Hz) 38 - 43 (240V, 50Hz) Polyethylene foam, Urethane foam PP honeycomb fabric (washable) Fuse LEV R410A, R407C, R22 CITY MULTI ø6.35 (ø1/4") Flare ø6.35 (ø1/4") Flare ø6.35 (ø1/4") Flare ø6.35 (ø1/4") Flare ø6.35 (ø1/4") Flare ø6.35 (ø1/4") Flare ø12.7 (ø1/2") Flare ø12.7 (ø1/2") Flare ø12.7 (ø1/2") Flare ø12.7 (ø1/2") Flare ø12.7 (ø1/2") Flare ø12.7 (ø1/2") Flare I.D. 26mm (1") IU-W65-3950 IU-W65-3960 Installation Manual, Instruction Book Drain hose (O.D.27mm(1-3/32"), (End O.D.20mm(13/16"))) (flexible joint) Optional parts Installation Note : PFFY-P25VLEM-E PFFY-P20VLEM-E Power source Cooling capacity (Nominal) G4 - Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual. ✻1 Nominal cooling conditions 27˚CDB/19˚CWB (81˚FDB/66˚FWB) 35˚CDB (95˚FDB) 7.5 m (24-9/16 ft) 0 m (0 ft) ✻2 Nominal cooling conditions 27˚CDB/19.5˚CWB (81˚FDB/67˚FWB) 35˚CDB (95˚FDB) 5 m (16-3/8 ft) 0 m (0 ft) ✻3 Nominal heating conditions 20˚CDB (68˚FDB) 7˚CDB/6˚CWB (45˚FDB/43˚FWB) 7.5 m (24-9/16 ft) 0 m (0 ft) * Nominal conditions ✻1, ✻3 are subject to JIS B8615-1. * Due to continuing improvement, above specification may be subject to change without notice. Unit converter kcal/h Btu/h cfm lb = kW x 860 = kW x 3,412 = m3/min x 35.31 = kg / 0.4536 *Above specification data is subject to rounding variation. Ref.: Spec_PFFY-P-VLE(R)M-E_1 PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E IU - H - 3 A B C D E F G H V-A V-B BC CT 10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx 25/4/08 15:16 Page 4 1. SPECIFICATIONS R410A Data Model PFFY-P50VLEM-E Power source Cooling capacity (Nominal) A B C D E F G H V-A V-B BC CT PFFY-P63VLEM-E PFFY-P20VLRM-E G4 PFFY-P25VLRM-E 1-phase 220-240V 50Hz, 1-phase 208-230V 60Hz 7.1 2.2 2.8 5.6 ✻1 6,100 1,900 2,400 4,800 ✻1 24,200 7,500 9,600 19,100 ✻2 6,300 2,000 2,500 5,000 Power input 0.1 / 0.11 0.04 / 0.06 0.04 / 0.06 0.085 / 0.09 Current input 0.46 / 0.47 0.19 / 0.25 0.19 / 0.25 0.40 / 0.41 ✻3 Heating capacity 8.0 2.5 3.2 6.3 ✻3 (Nominal ) 6,900 2,200 2,800 5,400 ✻3 27,300 8,500 10,900 21,500 Power input 0.1 / 0.11 0.04 / 0.06 0.04 / 0.06 0.085 / 0.09 Current input 0.46 / 0.47 0.19 / 0.25 0.19 / 0.25 0.40 / 0.41 Acrylic painted, MUNSELL (5Y 8/1) Galvanized External finish mm External dimension H x W x D 630 x 1,410 x 220 639 x 886 x 220 639 x 886 x 220 630 x 1,410 x 220 in. 24-13/16" x 55-9/16" x 8-11/16" 24-13/16" x 55-9/16" x 8-11/16" 25-3/16" x 34-15/16" x 8-11/16" 25-3/16" x 34-15/16" x 8-11/16" kg (lb) Net weight 30 (67) 32 (71) 18.5 (41) 18.5 (41) Cross fin (Aluminium fin and copper tube) Heat exchanger Type x Quantity FAN Sirocco fan x 2 Sirocco fan x 2 Sirocco fan x 1 Sirocco fan x 1 External Pa 0 0 0 0 static press. mmH2O 0 0 0 0 Motor type 1-phase induction motor Motor output 0.035 0.050 0.015 0.015 kW Driving mechanism Direct-driven by motor Airflow rate 12.0 - 14.0 12.0 - 15.5 5.5 - 6.5 5.5 - 6.5 m3 / min (Low-High) 200 - 233 200 - 258 92 - 108 92 - 108 L/s 424 - 494 424 - 547 194 - 230 194 - 230 cfm Noise level (Low-High) dB 36 - 41 (220V, 50Hz) 38 - 44 (220V, 50Hz) 32 - 38 (220V, 50Hz) 32 - 38 (220V, 50Hz) (measured in anechoic room) dB 37 - 42 (230V, 50Hz) 39 - 45 (230V, 50Hz) 33 - 39 (230V, 50Hz) 33 - 39 (230V, 50Hz) dB 38 - 43 (240V, 50Hz) 40 - 46 (240V, 50Hz) 34 - 40 (240V, 50Hz) 34 - 40 (240V, 50Hz) Polyethylene foam, Urethane foam Insulation material PP honeycomb fabric (washable) Air filter Fuse Protection device LEV Refrigerant control device R410A, R407C, R22 CITY MULTI Connectable outdoor unit Liquid Diameter of ø6.35 (ø1/4") Flare ø9.52 (ø3/8") Flare ø6.35 (ø1/4") Flare ø6.35 (ø1/4") Flare (R410A) mm (in.) refrigerant pipe ø9.52 (ø3/8") Flare ø9.52 (ø3/8") Flare ø6.35 (ø1/4") Flare ø6.35 (ø1/4") Flare (R22, R407C) Gas ø12.7 (ø1/2") Flare ø15.88 (ø5/8") Flare ø12.7 (ø1/2") Flare ø12.7 (ø1/2") Flare (R410A) mm (in.) ø15.88 (ø5/8") Flare ø15.88 (ø5/8") Flare ø12.7 (ø1/2") Flare ø12.7 (ø1/2") Flare (R22, R407C) I.D. 26mm (1") Field drain pipe size mm (in.) External Drawing IU-W65-3950 IU-W65-3950 IU-W65-3951 IU-W65-3951 Wiring IU-W65-3960 IU-W65-3960 IU-W65-3960 IU-W65-3960 Refrigerant cycle Document Installation Manual, Instruction Book Standard Accessory Drain hose (O.D.27mm(1-3/32"), (End O.D.20mm(13/16"))) (flexible joint) attachment Remark ✻1 kW kcal / h Btu / h kcal / h kW A kW kcal / h Btu / h kW A Optional parts Installation Note : Indoor : Outdoor : Pipe length : Level difference : - Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual. ✻1 Nominal cooling conditions 27˚CDB/19˚CWB (81˚FDB/66˚FWB) 35˚CDB (95˚FDB) 7.5 m (24-9/16 ft) 0 m (0 ft) ✻2 Nominal cooling conditions 27˚CDB/19.5˚CWB (81˚FDB/67˚FWB) 35˚CDB (95˚FDB) 5 m (16-3/8 ft) 0 m (0 ft) ✻3 Nominal heating conditions 20˚CDB (68˚FDB) 7˚CDB/6˚CWB (45˚FDB/43˚FWB) 7.5 m (24-9/16 ft) 0 m (0 ft) * Nominal conditions ✻1, ✻3 are subject to JIS B8615-1. * Due to continuing improvement, above specification may be subject to change without notice. Unit converter kcal/h Btu/h cfm lb = kW x 860 = kW x 3,412 = m3/min x 35.31 = kg / 0.4536 *Above specification data is subject to rounding variation. Ref.: Spec_PFFY-P-VLE(R)M-E_2 PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E IU - H - 4 10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx 25/4/08 15:16 Page 5 1. SPECIFICATIONS R410A Data Model ✻1 ✻1 ✻1 ✻2 Power input Current input ✻3 Heating capacity (Nominal ) ✻3 ✻3 Power input Current input External finish External dimension H x W x D Net weight Heat exchanger FAN Type x Quantity External static press. Motor type Motor output Driving mechanism Airflow rate (Low-High) Noise level (Low-High) (measured in anechoic room) kW kcal / h Btu / h kcal / h kW A kW kcal / h Btu / h kW A 3.6 3,100 12,300 3,150 0.06 / 0.07 0.29 / 0.30 4.0 3,400 13,600 0.06 / 0.07 0.29 / 0.30 mm in. kg (lb) 639 x 1,006 x 220 25-3/16" x 39-5/8" x 8-11/16" 20 (45) Sirocco fan x 2 0 0 Pa mmH2O 0.018 kW 7.0 - 9.0 117 - 150 247 - 318 33 - 38 (220V, 50Hz) 34 - 39 (230V, 50Hz) 35 - 40 (240V, 50Hz) m3 / min L/s cfm dB dB dB Insulation material Air filter Protection device Refrigerant control device Connectable outdoor unit Liquid Diameter of (R410A) mm (in.) refrigerant pipe (R22, R407C) Gas (R410A) mm (in.) (R22, R407C) Field drain pipe size mm (in.) External Drawing Wiring Refrigerant cycle Document Standard Accessory attachment Remark Indoor : Outdoor : Pipe length : Level difference : ø6.35 (ø1/4") Flare ø6.35 (ø1/4") Flare ø12.7 (ø1/2") Flare ø12.7 (ø1/2") Flare PFFY-P50VLRM-E PFFY-P63VLRM-E 1-phase 220-240V 50Hz, 1-phase 208-230V 60Hz 4.5 5.6 7.1 3,900 4,800 6,100 15,400 19,100 24,200 4,000 5,000 6,300 0.065 / 0.075 0.085 / 0.09 0.1 / 0.11 0.32 / 0.33 0.40 / 0.41 0.46 / 0.47 5.0 6.3 8.0 4,300 5,400 6,900 17,100 21,500 27,300 0.065 / 0.075 0.085 / 0.09 0.1 / 0.11 0.32 / 0.33 0.40 / 0.41 0.46 / 0.47 Galvanized 639 x 1,006 x 220 639 x 1,246 x 220 639 x 1,246 x 220 25-3/16" x 39-5/8" x 8-11/16" 25-3/16" x 49-1/16" x 8-11/16" 25-3/16" x 49-1/16" x 8-11/16" 21 (47) 25 (56) 27 (60) Cross fin (Aluminium fin and copper tube) Sirocco fan x 2 Sirocco fan x 2 Sirocco fan x 2 0 0 0 0 0 0 1-phase induction motor 0.030 0.035 0.050 Direct-driven by motor 9.0 - 11.0 12.0 - 14.0 12.0 - 15.5 150 - 183 200 - 233 200 - 258 318 - 388 424 - 494 424 - 547 36 - 41 (220V, 50Hz) 36 - 41 (220V, 50Hz) 38 - 44 (220V, 50Hz) 37 - 42 (230V, 50Hz) 37 - 42 (230V, 50Hz) 39 - 45 (230V, 50Hz) 38 - 43 (240V, 50Hz) 38 - 43 (240V, 50Hz) 40 - 46 (240V, 50Hz) Polyethylene foam, Urethane foam PP honeycomb fabric (washable) Fuse LEV R410A, R407C, R22 CITY MULTI ø6.35 (ø1/4") Flare ø6.35 (ø1/4") Flare ø9.52 (ø3/8") Flare ø6.35 (ø1/4") Flare ø9.52 (ø3/8") Flare ø9.52 (ø3/8") Flare ø12.7 (ø1/2") Flare ø12.7 (ø1/2") Flare ø15.88 (ø5/8") Flare ø12.7 (ø1/2") Flare ø15.88 (ø5/8") Flare ø15.88 (ø5/8") Flare I.D. 26mm (1") IU-W65-3951 IU-W65-3960 Installation Manual, Instruction Book Drain hose (O.D.27mm(1-3/32"), (End O.D.20mm(13/16"))) (flexible joint) Optional parts Installation Note : PFFY-P40VLRM-E PFFY-P32VLRM-E Power source Cooling capacity (Nominal) G4 - Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual. ✻1 Nominal cooling conditions 27˚CDB/19˚CWB (81˚FDB/66˚FWB) 35˚CDB (95˚FDB) 7.5 m (24-9/16 ft) 0 m (0 ft) ✻2 Nominal cooling conditions 27˚CDB/19.5˚CWB (81˚FDB/67˚FWB) 35˚CDB (95˚FDB) 5 m (16-3/8 ft) 0 m (0 ft) ✻3 Nominal heating conditions 20˚CDB (68˚FDB) 7˚CDB/6˚CWB (45˚FDB/43˚FWB) 7.5 m (24-9/16 ft) 0 m (0 ft) * Nominal conditions ✻1, ✻3 are subject to JIS B8615-1. * Due to continuing improvement, above specification may be subject to change without notice. Unit converter kcal/h Btu/h cfm lb = kW x 860 = kW x 3,412 = m3/min x 35.31 = kg / 0.4536 *Above specification data is subject to rounding variation. Ref.: Spec_PFFY-P-VLE(R)M-E_3 PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E IU - H - 5 A B C D E F G H V-A V-B BC CT 10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx 25/4/08 15:16 Page 6 1. SPECIFICATIONS Model PFFY-P20VLRMM-E Power source Cooling capacity (Nominal) ✻1 ✻1 ✻1 ✻2 Power input Current input ✻3 Heating capacity (Nominal ) ✻3 ✻3 A B C D E F G H V-A V-B BC CT R410A Data Power input Current input External finish External dimension H x W x D kW kcal / h Btu / h kcal / h kW A kW kcal / h Btu / h kW A PFFY-P25VLRMM-E PFFY-P32VLRMM-E PFFY-P40VLRMM-E 1-phase 220-240V (50/60Hz) 2.8 3.6 2,400 3,100 9,600 12,300 2,500 3,150 0.04 0.04 0.34 0.38 3.2 4.0 2,800 3,400 10,900 13,600 0.04 0.04 0.34 0.38 2.2 1,900 7,500 2,000 0.04 0.34 2.5 2,200 8,500 0.04 0.34 G4 4.5 3,900 15,400 4,000 0.05 0.43 5.0 4,300 17,100 0.05 0.43 Galvanized steel plate 639 x 886 x 220 639 x 1006 x 220 639 x 1006 x 220 639 x 886 x 220 25-3/16" x 34-15/16" x 8-11/16" 25-3/16" x 34-15/16" x 8-11/16" 25-3/16" x 39-5/8" x 8-11/16" 25-3/16" x 39-5/8" x 8-11/16" 18.5 (41) 18.5 (41) 20 (45) 21(47) Net weight Cross fin (Aluminium fin and copper tube) Heat exchanger Type x Quantity Sirocco fan x 1 Sirocco fan x 1 Sirocco fan x 2 Sirocco fan x 2 FAN External Pa 20 - 40 - 60 20 - 40 - 60 20 - 40 - 60 20 - 40 - 60 static press. mmH2O 2.0 - 4.1 - 6.1 2.0 - 4.1 - 6.1 2.0 - 4.1 - 6.1 2.0 - 4.1 - 6.1 Motor type DC blushless motor Motor output 0.096 0.096 0.096 0.096 kW Driving mechanism Direct-driven Airflow rate 4.5 - 5.5 - 6.5 4.5 - 5.5 - 6.5 6.5 - 7.5 - 9.0 8.0 - 9.5 - 11.0 m3 / min (Low-Mid-High) 75 - 92 - 108 75 - 92 - 108 108 - 125 - 150 133 - 158 - 183 L/s 159 - 194 - 230 159 - 194 - 230 230 - 265 - 318 283 - 335 - 388 cfm 31 - 36 - 40 (20Pa) 31 - 36 - 40 (20Pa) 27 - 32 - 37 (20Pa) 30 - 36 - 40 (20Pa) Noise level (Low-Mid-High) dB 34 - 39 - 42 (40Pa) 34 - 39 - 42 (40Pa) 30 - 35 - 41 (40Pa) 32 - 38 - 42 (40Pa) (measured in anechoic room) dB 35 - 40 - 43 (60Pa) 35 - 40 - 43 (60Pa) 32 - 37 - 42 (60Pa) 35 - 39 - 44 (60Pa) dB Polyethylene foam, Urethane foam Insulation material PP honeycomb fabric (washable) Air filter Fuse Protection device LEV Refrigerant control device R410A CITY MULTI Connectable outdoor unit Liquid ø6.35 (ø1/4") Brazed ø6.35 (ø1/4") Brazed ø6.35 (ø1/4") Brazed ø6.35 (ø1/4") Brazed Diameter of (R410A) mm (in.) refrigerant pipe Gas ø12.7 (ø1/2") Brazed ø12.7 (ø1/2") Brazed ø12.7 (ø1/2") Brazed ø12.7 (ø1/2") Brazed (R410A) mm (in.) Field drain pipe size External Drawing Wiring Refrigerant cycle Document Standard Accessory attachment Remark mm in. kg (lb) Indoor : Outdoor : Pipe length : Level difference : IU-KB94-L081 IU-KB94-G985 - IU-KB94-L081 IU-KB94-L081 IU-KB94-L081 IU-KB94-G985 IU-KB94-G985 IU-KB94-G985 Installation Manual, Instruction Book Screw plate, Level adjusting screw, Strainer, Drain hose (flexible joint), Hose band Optional parts Installation Note : I.D. 26mm (1") mm (in.) - Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual. ✻1 Nominal cooling conditions 27˚CDB/19˚CWB (81˚FDB/66˚FWB) 35˚CDB (95˚FDB) 7.5 m (24-9/16 ft) 0 m (0 ft) ✻2 Nominal cooling conditions 27˚CDB/19.5˚CWB (81˚FDB/67˚FWB) 35˚CDB (95˚FDB) 5 m (16-3/8 ft) 0 m (0 ft) ✻3 Nominal heating conditions 20˚CDB (68˚FDB) 7˚CDB/6˚CWB (45˚FDB/43˚FWB) 7.5 m (24-9/16 ft) 0 m (0 ft) * Nominal conditions ✻1, ✻3 are subject to JIS B8615-1. * Due to continuing improvement, above specification may be subject to change without notice. Unit converter kcal/h Btu/h cfm lb = kW x 860 = kW x 3,412 = m3/min x 35.31 = kg / 0.4536 *Above specification data is subject to rounding variation. Ref.: Spec_PFFY-P-VLRMM-E_1 PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E IU - H - 6 10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx 25/4/08 15:16 Page 7 1. SPECIFICATIONS Model ✻1 ✻1 ✻1 ✻2 Power input Current input ✻3 Heating capacity (Nominal ) ✻3 ✻3 Power input Current input External finish External dimension H x W x D mm in. kg (lb) Type x Quantity External static press. Motor type Motor output Driving mechanism Airflow rate (Low-Mid-High) Noise level (Low-Mid-High) (measured in anechoic room) Insulation material Air filter Protection device Refrigerant control device Connectable outdoor unit Liquid Diameter of refrigerant pipe Gas (R410A) (R410A) Field drain pipe size External Drawing Wiring Refrigerant cycle Document Standard Accessory attachment Remark kW kcal / h Btu / h kcal / h kW A kW kcal / h Btu / h kW A Indoor : Outdoor : Pipe length : Level difference : Sirocco fan x 2 20 - 40 - 60 2.0 - 4.1 - 6.1 0.096 10.0 - 12.0 - 14.0 167 - 200 - 233 353 - 424 - 494 32 - 37 - 41 (20Pa) 35 - 40 - 44 (40Pa) 36 - 41 - 45 (60Pa) m3 / min L/s cfm dB dB dB mm (in.) ø6.35 (ø1/4") Brazed ø12.7 (ø1/2") Brazed A B Galvanized steel plate 639 x 1246 x 220 25-3/16" x 49-1/16" x 8-11/16" 27 (60) Cross fin (Aluminium fin and copper tube) Sirocco fan x 2 20 - 40 - 60 2.0 - 4.1 - 6.1 DC blushless motor 0.096 Direct-driven 11.0 - 13.0-15.5 183 - 217 - 258 388 - 459 - 547 35 - 40 - 44 (20Pa) 36 - 42 - 47 (40Pa) 38 - 43 - 48 (60Pa) Polyethylene foam, Urethane foam PP honeycomb fabric (washable) Fuse LEV R410A CITY MULTI ø9.52 (ø3/8") Brazed C D E F G H V-A V-B BC CT ø15.88 (ø5/8") Brazed I.D. 26mm (1") mm (in.) IU-KB94-L081 IU-KB94-G985 - IU-KB94-L081 IU-KB94-G985 Installation Manual, Instruction Book Screw plate, Level adjusting screw, Strainer, Drain hose (flexible joint), Hose band Optional parts Installation Note : 639 x 1246 x 220 25-3/16" x 49-1/16" x 8-11/16" 25 (56) kW mm (in.) 1-phase 220-240V (50/60Hz) 7.1 6,100 24,200 6,300 0.07 0.59 8.0 6,900 27,300 0.07 0.59 5.6 4,800 19,100 5,000 0.05 0.48 6.3 5,400 21,500 0.05 0.48 Pa mmH2O G4 PFFY-P63VLRMM-E PFFY-P50VLRMM-E Power source Cooling capacity (Nominal) Net weight Heat exchanger FAN R410A Data - Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual. ✻1 Nominal cooling conditions 27˚CDB/19˚CWB (81˚FDB/66˚FWB) 35˚CDB (95˚FDB) 7.5 m (24-9/16 ft) 0 m (0 ft) ✻2 Nominal cooling conditions 27˚CDB/19.5˚CWB (81˚FDB/67˚FWB) 35˚CDB (95˚FDB) 5 m (16-3/8 ft) 0 m (0 ft) ✻3 Nominal heating conditions 20˚CDB (68˚FDB) 7˚CDB/6˚CWB (45˚FDB/43˚FWB) 7.5 m (24-9/16 ft) 0 m (0 ft) * Nominal conditions ✻1, ✻3 are subject to JIS B8615-1. * Due to continuing improvement, above specification may be subject to change without notice. Unit converter kcal/h Btu/h cfm lb = kW x 860 = kW x 3,412 = m3/min x 35.31 = kg / 0.4536 *Above specification data is subject to rounding variation. Ref.: Spec_PFFY-P-VLRMM-E_2 PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E IU - H - 7 50 630 Air inlet 100 220 90 35 Air outlet 6 20 PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E A 1050 1050 1170 1170 B 640 640 760 760 C 600 600 720 720 PFFY-P63VLEM-E 1410 1000 960 PFFY-P50VLEM-E 1410 1000 960 Dimensions Model PFFY-P20VLEM-E PFFY-P25VLEM-E PFFY-P32VLEM-E PFFY-P40VLEM-E Drain hose O.D. 27 (End O.D. 20) Strainer Drain pan Refrigerant piping flare connection(Liquid) F E(Gas) ø12.7 ø12.7 ø12.7 ø12.7 ✻1 ø12.7 970 ✻2 ø15.88 970 ø15.88 D 610 610 730 730 (60) 120 Refrigerant piping flare connection(Gas) E Note: 1. On Model :50, you would use flare nut packed with the Indoor Unit, when connecting the Outdoor Unit for R407C, R22. 2. In order to increase the strength of the flare nut, the size of some of them has been G increased. Level adjusting screw 4 pcs.(attached) 430 35 500 ( 75 ) 25 Piping space 170 220 F(Liquid) ø6.35 ø6.35 ø6.35 ø6.35 ✻1 ø6.35 ✻2 ø9.52 ø9.52 10 15 Air filter G(Liquid) G(Gas) 17 27 17 27 17 27 17 27 ✻1 22 ✻1 29 ✻2 22 ✻2 29 22 29 45 78 80 15 ✻1:R410A outdoor unit ✻2:R407C,R22 outdoor unit B D B A C 220 170 2-12 ✕16 Floor mounting hole 10 2 ✕ 2-12 ✕16 Wall mounting hole Remote controller (PAR-F27MEA) can be built-in. (Program timer can not be built-in together) 108 310 40 21 160 300 170 Air supply grille 15:16 183.5 25/4/08 106 10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx Page 9 2. EXTERNAL DIMENSIONS R410A Data PFFY-P20,25,32,40,50,63VLEM-E Drw. : IU-W65-3950 Unit : mm G4 A B C D E IU - H - F G H V-A V-B BC CT 9 30 8 90 35 49 9 Drain hose O.D. 27 (End O.D. 20) PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E D 610 610 730 730 970 970 PFFY-P50VLRM-E 1246 1000 932 PFFY-P63VLRM-E 1246 1000 932 B 640 640 760 760 C 572 572 692 692 A Model PFFY-P20VLRM-E 886 PFFY-P25VLRM-E 886 PFFY-P32VLRM-E 1006 PFFY-P40VLRM-E 1006 Dimensions 639 G(Gas) ø12.7 ø12.7 ø12.7 ø12.7 ø12.7 ✻1 720 7 ✻2 ø15.88 ø15.88 720 7 E F 360 4 360 4 480 5 480 5 H(Liquid) ø6.35 ø6.35 ø6.35 ø6.35 ø6.35 ✻1 ✻2 ø9.52 ø9.52 45 J(Liquid) 17 17 17 17 ✻1 22 ✻2 22 22 J(Gas) 27 27 27 27 ✻1 29 ✻2 29 29 Air filter G H V-A BC ✻1:R410A outdoor unit ✻2:R407C,R22 outdoor unit D B E 15 F 76 15 120 C 2 ✕ 2 - 12 ✕ 16 Wall mounting hole 2-12 ✕ 16 Floor mounting hole 167 E J Strainer Drain pan Refrigerant piping flare connection(Liquid) H Refrigerant piping flare connection(Gas) G 80 2 ✕ F - ø 4.7 Duct mounting hole CT 15:16 Note: 1. On Model :50, you would use flare nut packed with the Indoor Unit, when connecting the Outdoor Unit for R407C, R22. 2. In order to increase the strength of the flare nut, the size of some of them has been increased. Air inlet 220 98 A 25/4/08 Level adjusting screw 4 pcs.(attached) 100 84 Air outlet B 90 310 2- ø 4.7 Duct mounting hole 50 430 10 29 400 15 132 300 V-B 106 D ( 75 ) C 170 10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx Page 10 2. EXTERNAL DIMENSIONS R410A Data PFFY-P20,25,32,40,50,63VLRM-E Drw. : IU-W65-3951 Unit : mm IU - H - G4 A B 10 PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E 5 7 480 720 730 970 692 932 1000 4 360 610 572 640 760 F E D C B 90 ø15.88 ø12.7 Gas pipe 9 98 30 8 49 ø9.52 ø6.35 Liquid pipe 2-12X16 Floor mounting hole Drain hose(accessory) O.D.27mm(End O.D.20mm) Sub drain pan Drain pan 2 Refrigerant piping brazing connection (liquid) 2XF-ø4.7 Duct mounting hole 45 76 15 D Air inlet Air outlet B(Floor mounting hole pitch) 120 C E Air filter 15 2X2-12X16 Wall mounting hole 175 Control box Terminal bed(Transmission) Knockout holeø27 (Power souce wiring) Knockout hole ø27 (Transmission wiring) Terminal bed(Power souce) 2. EXTERNAL DIMENSIONS Dimensions Model A PFFY-P20VLRMM-E 886 PFFY-P25VLRMM-E PFFY-P32VLRMM-E 1006 PFFY-P40VLRMM-E PFFY-P50VLRMM-E 1246 PFFY-P63VLRMM-E 84 639 A PFFY-P20,25,32,40,50,63VLRMM-E Level adjusting screw 4 pcs.(attached) 1 Refrigerant piping brazing connection (gas) 387 220 344 2-ø4.7 Duct mounting hole 10 29 400 75 103 33 35 77 43 385 68 300 88 (Wall mounting hole pitch) B(Wall mounting hole pitch) 15:16 Floor mounting hole pitch 106 25/4/08 170 10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx Page 11 R410A Data G4 Drw. : IU-KB94-L081 Unit : mm A B C D E F G H V-A V-B BC CT IU - H - 11 10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx 25/4/08 15:16 Page 12 3. ELECTRICAL WIRING DIAGRAMS R410A Data PFFY-P20,25,32,40VKM-E G4 Drw. : IU-RG79-V367 [LEGEND] A B C D E SYMBOL I. B CN32 CN51 CN52 SW2 SW3 SW4 ZNR FUSE LED1 LED2 NAME INDOOR CONTROLLER BOARD CONNECTOR REMOTE SWITCH CENTRALLY CONTROL REMOTE INDICATION SWITCH CAPACITY CODE MODE SELECTION MODEL SELECTOR VARISTOR FUSE (T6.3AL250V) POWER SUPPLY (I.B) POWER SUPPLY (I.B) SYMBOL MF1 MF2 MV1 MV2 LS LEV TB2 TB5 TH21 NAME SYMBOL NAME FAN MOTOR (UPPER) TH23 PIPE TEMP. DETECTION/GAS FAN MOTOR (LOWER) (0 /15k , 25 /5.4k ) A. B VANE MOTOR ADDRESS BOARD SW1 SWITCH DAMPER MOTOR MODE SELECTION SW11 DAMPER LIMIT SWITCH (CLOSE) ADDRESS SETTING 1ST DIGIT SW12 LINEAR EXPANSION VALVE ADDRESS SETTING 2ND DIGIT SW14 TERMINAL POWER SUPPLY CONNECTION NO. BLOCK SWC TRANSMISSION AIR OUTLET SELECTION THERMISTOR ROOM TEMP. DETECTION (0 /15k , 25 /5.4k ) PIPE TEMP. DETECTION/LIQUID (0 /15k , 25 /5.4k ) : " : " : " : " : " : " TH22 NOTES V-A 1.At servicing for outdoor unit, always follow the wiring diagram of outdoor unit. 2.In case of connecting MA-Remote controller, please connect MA remote controller cable in an accessory to the connecter 1 2 . (Remote controller wire is non-polar.) 3.In case of using M-NET, please connect to TB5. (Transmission line is non-polar.) 4.Symbol [S] of TB5 is the shield wire connection. 5.Symbols used in wiring diagram above are, : terminal block, : connector. 6.The setting of the SW2 dip switches differs in the capacity for the detail, refer to the fig:w 1. V-B LED on indoor board for service FUNCTION Main power supply (Indoor unit:220-240V) LED1 Main power supply power on Iamp is Iit Power supply for Power supply for MA-remote controller LED2 MA-Remote controller on Iamp is lit SW2 P20 ON OFF P25 ON OFF P32 ON OFF P40 ON OFF 123456 123456 123456 TH21 TH23 TH22 LS 123456 LEV 6 I.B 3 2 1 6 5 4 3 2 1 4 3 2 1 3 2 1 CN31 (WHT) CN60 (WHT) CN44 (WHT) CN36 (BLK) 2 1 CN52 CN51 (GRN) (WHT) 1 2 3 4 5 6 1 2 3 4 5 6 TO MA-REMOTE CONTROLLER DC8.7-13V ORN 1 ORN 2 BLU PNK YLW ORN RED BRN TO OUTDOOR UNIT TB5 M1 BC CONTROLLER ME REMOTE CONTROLLER M2 DC24-30V S(SHIELD) BLU PNK YLW ORN RED BRN BLU BLU 1 2 3 4 5 6 1 2 3 4 5 6 SWC SW14 0 CONNECTION NO. 3RD 2ND 1ST DIGIT DIGIT DIGIT 1 2 3 CN6V1 (GRN) CN82 (RED) SW12 SW11 0 0 1 2 CN6V2 (BLU) CN43 (RED) SW1 CN2M CN3A (BLU) (BLU) 12345678910 CNMF2 (WHT) 4 3 2 1 ON OFF CND (BLK) 8 7 6 5 4 3 2 1 ON OFF BLU GRN/YLW CN42 (RED) 4 3 2 1 LED2 123456 TB2 RED CN32 (WHT) SW2 BLK 4 A.B 1 L N CNMF1 (WHT) SW3 ZNR BLK WHT BRN BLU 8 ON OFF SW4 DC311 ~339V FUSE RED 12345 CN81 (RED) 2 POWER SUPPLY 220-240V 50Hz SWE BLK WHT BRN BLU ON OFF MF1 RED ON OFF MF2 12345678910 CN20 (WHT) 1 2 3 4 5 6 7 8 LED1 2 1 CT MODELS MEANING MARK 8 6 4 2 7 5 3 1 BC 1 2 3 4 5 H 6 5 4 3 2 1 G 6 5 4 3 2 1 F See fig:w1 MV2 MV1 PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E IU - H - 12 9 0 1 CN62 1234 56 9 0 1 CN42 2 3 2 3 345 TH21 3 1 21 SYMBOL TH22 TH23 S W 11 ( A . B ) SW12(A.B) SW14(A.B) SW1(A.B) SW2(I.B) SW3(I.B) SW4(I.B) SW5(A.B) X04~06 21 CN31 CN60 LEV 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 1 T CN3T (White) 3 CNT F ) AC250V 6.3A F 3 1 ( NAME Thermistor (piping temp.detection/liquid) Thermistor (piping temp.detection/gas) Switch (1st digit address set) Switch (2nd digit address set) Switch (connection No.set) Switch(for mode selection) Switch(for capacity code) Switch(for mode selection) Switch(for model selection) Switch(for voltage selection) Aux.relay REMOTE INDICATION CN52 (Black) TH23 3 1 21 21 21 CN21 CN29 TH22 (White) NAME Fan motor ✻Capacitor (for MF) Indoor controller board Address board Power source terminal bed Transmission terminal bed Transmission terminal bed Fuse AC250V 6.3A F Transformer Electronic linear expan. valve Surge absorber board Thermistor (inlet temp.detection) SYMBOL EXPLANATION (Red) 2 1 CN20 (Red) (White) (Black) CENTRALLY CONTROL CN51 1 3 MODELS MODEL MODEL C MF 4 3 2 1 4 3 2 1 1 3 57 DSA1 ZNR1 CN2M 2 1 TB2 N PE 1.5µF 2.0µF 2.5µF 3 L M2 M1 S.B TO MA REMOTE CONTROLLER POWER SUPPLY ~ 220-240V 50Hz BREAKER(16A) FUSE(16A) PULL BOX TO NEXT INDOOR UNIT TO OUTDOOR UNIT BC CONTROLLER ME REMOTE CONTROLLER TB5 (TRANSMISSION TERMINAL BED) 2 1 TB15 (TRANSMISSION TERMINAL BED) S(SHIELD) CN1 1 20/25/32/40 50 63 FAN3 X06 X05 X04 ✻Capacitor (White) CND ZNR 3 1 15:16 SYMBOL MF C I.B A.B TB2 TB5 TB15 F T LEV S.B TH21 8 76 5 4 3 2 1 CN81 REMOTE SWITCH CN32 CN3A I.B 25/4/08 MODEL. P20/P25 ONLY CN82 8 7 6 5 4 3 2 1 SW4SW3 SW2 SW11 SW12 SW14 (Connection No.) (2nd digit) (1st digit) 89A E 67 F0 1 2 SW5 7 8 A.B 5 6 SW1 4 B CD 1 2 3 4 4 5 6 7 8 INSIDE SECTION OF CONTROL BOX 10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx Page 13 3. ELECTRICAL WIRING DIAGRAMS R410A Data PFFY-P20,25,32,40,50,63VLEM-E,VLRM-E PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E IU - H - G4 Drw. : IU-W65-3960 A B C D E F G H V-A V-B BC CT 13 PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E NAME Indoor controller board Fuse Varistor Arrester Connector (Damper) Connector (Remote switch) Connector (HA terminal-A) Connector (Centrally control) Connector (Remote indication) Connector (Wireless) Switch (for capacity code) Switch (for mode selection) Switch (for model selection) Connector (emergency operation) AC reactor(Power factor improvement) LEV M SYMBOL A.B. SW1 SW5 SW7 SW11 SW12 SW14 SWA SWC TB2 TB5 TB15 TH21 TH22 TH23 LEV TH22 tº 3 TH23 NAME TH21 tº 1 2 CN20 (Red) CN27 (Red) CN90 SW2 2 1 LED1 DC310~340V Rectify circuit CN2M (Blue) Address board Switch (for mode selection) Switch (for mode selection) Switch (for model selection) Switch (1st digit address set) Switch (2nd digit address set) Switch (connection No.set) Switch (for static pressure selection) Switch (for static pressure selection) Power source terminal bed Transmission terminal bed Transmission terminal bed Thermistor (inlet air temp.detection) Thermistor (piping temp.detection/liquid) Thermistor (piping temp.detection/gas) Electronic linear expan.valve tº 1 1 2 3 4 1 2 3 4 1 2 CN4F CN44 SWE OFF ON SW4 1 U FUSE 1 3 5 TB2 N L L1 POWER SUPPLY ~220,230,240V 50,60Hz BREAKER (16A) FUSE (16A) PULL BOX TO NEXT INDOOR UNIT only PFFY-P63VLRMM-E TO OUTDOOR UNIT BC CONTROLLER REMOTE CONTROLLER SYMBOL LED1 LED2 Lighting PFFY-P20,25,32,40,50,63VLRMM-E At applying main power source Lighting At receiving MA transmission power source LED operation under normal state OPERATION OF LED FOR INDOOR CIRCUIT BOARD SERVICE NOTE:1.The wirings to TB2,TB5,TB15 shown in dotted line are field work. 2.Mark indicates terminal bed, connector. Fan motor M 7 6 5 4 CNMF U ZNR01 ZNR02 DSA CND (Black) TB5 M2 M1 S(SHIELD) TO MA REMOTE CONTROLLER 15:16 SYMBOL I.B. FUSE ZNR01,02 DSA CN27 CN32 CN41 CN51 CN52 CN90 SW2 SW3 SW4 SWE L1 CN41 1 2 3 4 5 6 CN51 SW3 SW1 TB15 1 2 25/4/08 SYMBOL EXPLANATION (Green) CN52 LED2 CN42 (Red) 1 2 3 4 CN82 1 2 3 4 5 6 7 8 CT CN60 CN3A (Blue) CN81 (Red) 1 2 3 4 5 6 7 8 7 8 D 1 2 3 4 5 6 3 1 CN32 I.B. 1 2 3 4 CN62 SW11 (1st digit) 1 0 9 C SW12 SW14 (2nd digit) (Connection No.) 3 2 BC 7 8 B 1 0 9 V-B 3 2 A SW7 V-A INSIDE SECTION OF CONTROL BOX H 6 7 8 9 A SW5 SWC SWA B 5 4 C 3 21 0 F E D G 4 5 6 F 4 5 6 E A.B. 10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx Page 14 3. ELECTRICAL WIRING DIAGRAMS R410A Data IU - H - G4 Drw. : IU-KB94-G985 14 10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx 25/4/08 15:16 Page 15 4. SOUND LEVELS R410A Data G4 4-1. Sound levels PFFY-P-VKM-E,VLEM-E,VLRM-E Sound level at anechoic room : Low-High Sound level dB (A) 27-31-34-37 28-32-35-38 28-32-35-38 35-38-42-44 PFFY-P20VKM-E PFFY-P25VKM-E PFFY-P32VKM-E PFFY-P40VKM-E PFFY-P20VLEM-E PFFY-P20VLRM-E PFFY-P25VLEM-E PFFY-P25VLRM-E PFFY-P32VLEM-E PFFY-P32VLRM-E PFFY-P40VLEM-E PFFY-P40VLRM-E PFFY-P50VLEM-E PFFY-P50VLRM-E PFFY-P63VLEM-E PFFY-P63VLRM-E 1.0m 1.0m Measurement location * Measured in anechoic room. PFFY-P-VLRMM-E 34-40 A 35-40 B 38-43 C D 40-46 Aux. duct Sound level at anechoic room : Low-middle-High Sound level dB (A) 20Pa 40Pa 60Pa 1.0m 31-36-40 31-36-40 27-32-37 30-36-40 32-37-41 35-40-44 PFFY-P20VLRMM-E PFFY-P25VLRMM-E PFFY-P32VLRMM-E PFFY-P40VLRMM-E PFFY-P50VLRMM-E PFFY-P63VLRMM-E 1.0m 1.0m Measurement location 34-39-42 34-39-42 30-35-41 32-38-42 35-40-44 36-42-47 35-40-43 35-40-43 32-37-42 35-39-44 36-41-45 38-43-48 E F G H V-A V-B BC * Measured in anechoic room. CT 4-2. NC curves 70 Cooling Heating 60 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 0 63 125 250 500 1000 2000 4000 PFFY-P40VKM-E External static pressure : 0Pa Power source : 220,230,240V, 50Hz 70 Cooling Heating 60 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 0 8000 63 125 250 500 1000 2000 4000 OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa PFFY-P25,32VKM-E External static pressure : 0Pa Power source : 220,230,240V, 50Hz OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa PFFY-P20VKM-E External static pressure : 0Pa Power source : 220,230,240V, 50Hz 70 Cooling Heating 60 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 0 8000 63 125 250 500 1000 2000 4000 8000 PFFY-P20,25VLEM-E,VLRM-E External static pressure : 0Pa Power source : 220,230,240V, 50Hz / 208,220,230V, 60Hz PFFY-P32VLEM-E,VLRM-E External static pressure : 0Pa Power source : 220,230,240V, 50Hz / 208,220,230V, 60Hz PFFY-P40VLEM-E,VLRM-E External static pressure : 0Pa Power source : 220,230,240V, 50Hz / 208,220,230V, 60Hz 70 High speed Low speed 60 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 0 63 125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCIES (Hz) 8000 70 High speed Low speed 60 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 0 63 125 250 500 1000 2000 4000 8000 OCTAVE BAND CENTER FREQUENCIES (Hz) PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa OCTAVE BAND CENTER FREQUENCIES (Hz) OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa OCTAVE BAND CENTER FREQUENCIES (Hz) OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa OCTAVE BAND CENTER FREQUENCIES (Hz) 70 High speed Low speed 60 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 0 63 125 250 500 1000 2000 4000 8000 OCTAVE BAND CENTER FREQUENCIES (Hz) IU - H - 15 10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx 25/4/08 15:16 Page 16 4. SOUND LEVELS R410A Data G4 4-2. NC curves NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise G H V-A V-B BC 500 1000 2000 4000 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 0 8000 63 PFFY-P20,25VLRMM-E External static pressure : 20Pa Power source : 220,230,240V, 50/60Hz CT 70 60 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 63 125 250 500 1000 2000 4000 OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 250 500 1000 2000 4000 50 NC50 40 NC40 30 NC30 20 NC20 10 0 Approximate minimum audible limit on continuous noise 63 OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 125 250 500 1000 2000 4000 250 500 1000 2000 4000 High speed Middle speed Low speed 60 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 0 63 8000 70 High speed Middle speed Low speed NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 63 125 250 500 1000 2000 4000 8000 70 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 250 500 1000 2000 4000 2000 4000 8000 High speed Middle speed Low speed 60 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 0 63 125 250 500 1000 2000 4000 8000 PFFY-P40VLRMM-E External static pressure : 60Pa Power source : 220,230,240V, 50/60Hz NC60 125 1000 OCTAVE BAND CENTER FREQUENCIES (Hz) High speed Middle speed Low speed 63 500 70 8000 60 0 250 PFFY-P32VLRMM-E External static pressure : 60Pa Power source : 220,230,240V, 50/60Hz 60 0 125 OCTAVE BAND CENTER FREQUENCIES (Hz) PFFY-P40VLRMM-E External static pressure : 40Pa Power source : 220,230,240V, 50/60Hz 60 OCTAVE BAND CENTER FREQUENCIES (Hz) 125 70 OCTAVE BAND CENTER FREQUENCIES (Hz) High speed Middle speed Low speed 63 PFFY-P20,25VLRMM-E External static pressure : 60Pa Power source : 220,230,240V, 50/60Hz NC60 8000 PFFY-P40VLRMM-E External static pressure : 20Pa Power source : 220,230,240V, 50/60Hz 0 8000 High speed Middle speed Low speed OCTAVE BAND CENTER FREQUENCIES (Hz) 70 4000 PFFY-P32VLRMM-E External static pressure : 40Pa Power source : 220,230,240V, 50/60Hz 60 125 2000 OCTAVE BAND CENTER FREQUENCIES (Hz) High speed Middle speed Low speed 63 1000 60 8000 PFFY-P32VLRMM-E External static pressure : 20Pa Power source : 220,230,240V, 50/60Hz 0 500 70 OCTAVE BAND CENTER FREQUENCIES (Hz) 70 250 PFFY-P20,25VLRMM-E External static pressure : 40Pa Power source : 220,230,240V, 50/60Hz High speed Middle speed Low speed 0 125 OCTAVE BAND CENTER FREQUENCIES (Hz) OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa F 250 NC60 50 OCTAVE BAND CENTER FREQUENCIES (Hz) OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa E 125 High speed Low speed 60 OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa 63 D 70 8000 OCTAVE BAND CENTER FREQUENCIES (Hz) PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa 0 OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa 60 OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa C High speed Low speed OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa B 70 PFFY-P63VLEM-E,VLRM-E External static pressure : 0Pa Power source : 220,230,240V, 50Hz / 208,220,230V, 60Hz OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa A OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa PFFY-P50VLEM-E,VLRM-E External static pressure : 0Pa Power source : 220,230,240V, 50Hz / 208,220,230V, 60Hz 70 High speed Middle speed Low speed 60 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 0 63 125 250 500 1000 2000 4000 8000 OCTAVE BAND CENTER FREQUENCIES (Hz) IU - H - 16 10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx 25/4/08 15:16 Page 17 4. SOUND LEVELS R410A Data G4 4-2. NC curves 60 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 0 63 125 250 500 1000 2000 4000 70 High speed Middle speed Low speed 60 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 0 Approximate minimum audible limit on continuous noise 63 8000 OCTAVE BAND CENTER FREQUENCIES (Hz) NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCIES (Hz) 8000 OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa 60 63 500 1000 2000 4000 High speed Middle speed Low speed 60 NC60 50 NC50 40 NC40 70 NC30 B 20 NC20 10 63 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 63 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 8000 D E PFFY-P63VLRMM-E External static pressure : 60Pa Power source : 220,230,240V, 50/60Hz 60 0 C Approximate minimum audible limit on continuous noise 0 OCTAVE BAND CENTER FREQUENCIES (Hz) High speed Middle speed Low speed 8000 OCTAVE BAND CENTER FREQUENCIES (Hz) PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E A 30 8000 PFFY-P63VLRMM-E External static pressure : 40Pa Power source : 220,230,240V, 50/60Hz High speed Middle speed Low speed 0 250 70 OCTAVE BAND CENTER FREQUENCIES (Hz) PFFY-P63VLRMM-E External static pressure : 20Pa Power source : 220,230,240V, 50/60Hz 70 125 OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa High speed Middle speed Low speed PFFY-P50VLRMM-E External static pressure : 60Pa Power source : 220,230,240V, 50/60Hz OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa 70 PFFY-P50VLRMM-E External static pressure : 40Pa Power source : 220,230,240V, 50/60Hz OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa PFFY-P50VLRMM-E External static pressure : 20Pa Power source : 220,230,240V, 50/60Hz 70 F High speed Middle speed Low speed G 60 NC60 H 50 NC50 40 NC40 V-A 30 NC30 V-B 20 NC20 BC 10 Approximate minimum audible limit on continuous noise 0 63 125 250 500 1000 2000 4000 CT 8000 OCTAVE BAND CENTER FREQUENCIES (Hz) IU - H- 17 10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx 25/4/08 15:16 Page 18 4. SOUND LEVELS R410A Data G4 4-3. Fan characteristics curves PFFY-P20,25VLRMM-E External static pressure : 20Pa Power source : 220,230,240V, 50/60Hz PFFY-P20,25VLRMM-E External static pressure : 40Pa Power source : 220,230,240V, 50/60Hz 50 30 Limit Limit 40 High A Static pressure (Pa) C Static pressure (Pa) B High 20 Middle 10 30 Middle 20 Low Low D 10 E F 0 4 5 6 Airflow rate (m3/min) G H 7 0 8 PFFY-P20,25VLRMM-E External static pressure : 60Pa Power source : 220,230,240V, 50/60Hz 4 5 6 Airflow rate (m3/min) 7 8 PFFY-P32VLRMM-E External static pressure : 20Pa Power source : 220,230,240V, 50/60Hz V-A 30 70 Limit Limit V-B 60 High BC 50 CT High Static pressure (Pa) Static pressure (Pa) 20 Middle 40 30 Low Middle Low 10 20 10 0 4 5 6 Airflow rate (m3/min) 7 0 8 PFFY-P32VLRMM-E External static pressure : 40Pa Power source : 220,230,240V, 50/60Hz 5 6 7 8 9 Airflow rate (m3/min) 10 11 10 11 PFFY-P32VLRMM-E External static pressure : 60Pa Power source : 220,230,240V, 50/60Hz 70 50 Limit Limit High 60 High 40 Static pressure (Pa) Static pressure (Pa) 50 30 Middle Low 20 Middle 40 Low 30 20 10 10 0 5 6 7 8 9 Airflow rate (m3/min) 10 11 0 5 6 PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E 7 8 9 Airflow rate (m3/min) IU - H - 18 10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx 25/4/08 15:16 Page 19 4. SOUND LEVELS R410A Data G4 4-3. Fan characteristics curves PFFY-P40VLRMM-E External static pressure : 20Pa Power source : 220,230,240V, 50/60Hz PFFY-P40VLRMM-E External static pressure : 40Pa Power source : 220,230,240V, 50/60Hz 30 50 Limit Limit High 40 High A Static pressure (Pa) Static pressure (Pa) 20 Middle Low Middle 30 B C Low 20 10 D E 10 F 0 7 8 9 10 11 Airflow rate (m3/min) 12 0 13 PFFY-P40VLRMM-E External static pressure : 60Pa Power source : 220,230,240V, 50/60Hz 7 8 9 10 11 Airflow rate (m3/min) 12 13 G PFFY-P50VLRMM-E External static pressure : 20Pa Power source : 220,230,240V, 50/60Hz H V-A 40 70 V-B Limit Limit High 60 BC 30 CT Static pressure (Pa) Static pressure (Pa) 50 Middle 40 Low 30 20 High 20 Middle Low 10 10 0 7 8 9 10 11 Airflow rate (m3/min) 12 0 13 PFFY-P50VLRMM-E External static pressure : 40Pa Power source : 220,230,240V, 50/60Hz 8 9 10 11 12 13 Airflow rate (m3/min) 14 15 16 15 16 PFFY-P50VLRMM-E External static pressure : 60Pa Power source : 220,230,240V, 50/60Hz 50 70 Limit Limit High 60 High 40 Middle Static pressure (Pa) Static pressure (Pa) 50 30 Low 20 Middle 40 Low 30 20 10 10 0 8 9 10 11 12 13 Airflow rate (m 3/min) 14 15 16 0 8 9 PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E 10 11 12 13 Airflow rate (m3/min) 14 IU - H - 19 10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx 25/4/08 15:16 Page 20 4. SOUND LEVELS R410A Data G4 4-3. Fan characteristics curves PFFY-P63VLRMM-E External static pressure : 20Pa Power source : 220,230,240V, 50/60Hz 40 PFFY-P63VLRMM-E External static pressure : 40Pa Power source : 220,230,240V, 50/60Hz 60 Limit Limit 50 30 A Static pressure (Pa) C Static pressure (Pa) B High 40 High Middle 20 Low Middle 30 Low D 10 E 10 F 0 G H V-A 9 10 11 12 13 14 15 Airflow rate (m3/min) 16 17 18 17 18 0 9 10 11 12 13 14 15 Airflow rate (m3/min) 16 17 18 PFFY-P63VLRMM-E External static pressure : 60Pa Power source : 220,230,240V, 50/60Hz 70 Limit V-B High 60 BC 50 Static pressure (Pa) CT Middle 40 Low 30 20 10 0 9 10 11 12 13 14 15 Airflow rate (m3/min) 16 PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E IU - H - 20 10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx 25/4/08 15:16 Page 21 5. TEMPERATURE/AIRFLOW DISTRIBUTIONS R410A Data G4 5-1. Temperature distributions PFFY-P-VLEM-E,VLRM-E Room temp. : 27˚C Room temp. : 20˚C 3 3 25 24 25 23 29 26 2 24 30 Height (m) 22 Height (m) A 2 20 1 B 33 C 1 D E 1 2 3 4 1 Floor distance (m) 2 3 4 F Floor distance (m) G H PFFY-P-VKM-E V-A V-B 19.71 2.4 19.71 BC 33.29 33.29 21.00 27.43 2.0 2.4 18.43 2.0 CT 31.43 26.14 18.43 23.57 15.86 1.0 Height (m) Height (m) 31.43 17.14 22.29 24.86 35.14 37.00 1.0 40.71 14.57 13.29 23.57 38.86 31.43 21.00 17.14 22.29 6.37 6.0 42.57 35.14 23.57 5.0 4.0 3.0 Floor distance (m) 2.0 37.00 38.86 15.86 1.0 19.71 18.43 0 6.37 6.0 5.0 14.57 4.0 3.0 2.0 1.0 Floor distance (m) 0 40.71 Note : These figures show typical temperature distributions in the conditions above. In the actual installation, they may differ from these figures under the influence of air temperature conditions, ceiling height, cooling/heating load,obstacles,etc. PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E IU - H - 21 10_PFFY-P-VKM,VLEM,VLRM.qx:10_PFFY-P-VKM,VLEM,VLRM.qx 25/4/08 15:16 Page 22 5. TEMPERATURE/AIRFLOW DISTRIBUTIONS R410A Data G4 5-2. Airflow distributions PFFY-P-VLEM-E,VLRM-E Room temp. : 27˚C 0.5 1.0 1.5 2.0 2.5 3.0 Room temp. : 20˚C Distance (m) 3.5 4.0 0.5 3.0 0.9 1.7 Distance (m) 3.5 4.0 3.0 0. Height (m) 5 0. 9 4 1. 9 1.5 0. 4 0. 4 3 1.0 8 1. 0. 4 1. 0. 0.5 3 0.5 0.8 0.7 0.6 1. 0 75 0. 8 Height (m) 2.5 1.3 1.4 5 0. 7 7 1. 1. 0. D 6 2.0 4 0. 1.5 1.0 2.0 1. 8 65 2.0 0. 0.6 2.5 0. A C 1.5 3.0 2.5 B 1.0 9 0. 3 E 0 0 F G H V-B Unit: m/s Unit: m/s 0.65 2.4 BC 0.13 2.4 0.48 0.91 CT 1.12 1.17 0.39 Height (m) 0.80 0.16 2.0 2.0 0.39 1.43 0.39 1.69 1.95 2.21 1.0 1.44 0.16 Height (m) V-A PFFY-P-VKM-E 1.76 1.0 2.08 0.48 2.40 0.13 0.13 0.39 0.80 0.65 6.37 6.0 5.0 4.0 3.0 Floor distance (m) 2.0 1.12 1.17 1.0 0 6.37 6.0 5.0 1.43 1.69 1.95 4.0 3.0 Floor distance (m) 2.0 1.0 0 1.44 1.76 Note : These figures show typical airflow distributions in the conditions above. In the actual installation, they may differ from these figures under the influence of air temperature conditions, ceiling height, cooling/heating load,obstacles,etc. PFFY-P-VKM-E,VLEM-E,VLRM-E,VLRMM-E IU - H - 22