AX3700 auto amplifier changeover 6 Duty / 1 Standby Auto Amplifier Changeover Panel Amperes AX3700 offers a great flexibility and simplicity in cabling for auto amplifier fault changeover system with its combination of amplifier fault sensor modules and changeover panel in a box. The internally generated Pilot Tone and sensory circuit shall detect any faulty duty amplifier and would initiate a changeover process. AX3700 has been optimised for faster fault detection and changeover as compared with AS4000 modules. Pilot tones are generated at intervals to avoid constant loading of power amplifiers. amplifier changeover & monitoring Changeover are performed at both input and output sections, making it suitable for application in a matrix system. At any one time, only a failed duty unit shall be replaced by a standby amp, to avoid overloading. technical specifications Features Cater for 6 duty and 1 standby Operating voltage 24V DC 1 A via PS9400 PSU Expandable for 1 standby to cater for more than 6 duty amps. Power consumption 7.2 W Built in Pilot Tone generator, transmit at intervals and senses at Input signal 6 ch. balanced line signal sequence to protect amplifiers Input impedance 10 K Ohm Overloading protection by allowing only a single take over Audio output gain Unity Prioritised changeover which higher numbered amplifier shall be Pilot tone interval 10 secs / channel preferred for take over if more than two units are down Pilot tone frequency 20 KHz ( +/- 5% ) Shorter fault detection time from 10 to 25 seconds Detection line 70 / 100 V line Changeover at input and output section simultaneously ; suitable Detection level 50 V rms for matrix system installations Failure detection time 10 ~ 25 seconds Input link switch ; making connection of sources easier Failure recovery time 20 seconds max Channel isolation switch for unused or un-monitored channel Zone load rating 400W / 100V line Individual channel status indicators ; normal, fault and changeover Status indications Normal ; Fault ; Changeover Changeover alert Buzzer with switch Changeover section Input and Output simultaneously Dimensions (WxHxD) 482 x 88 x 150 mm Weight 3.4 kg application schematic INPUT SOURCES MIN MAX SIG IN MIN CH5 MAX MIN SIG IN CH6 MAX SIG IN MIN SOURCE MAX SIG IN MIN EXT INPUT MAX CHIME MAX MIN OFF MASTER TONE CTRL SELECT POWER TREBLE BASS MIN O AUX MAX SIG IN MUSIC SOURCE 24V DC overriding MIC TEST FIRE SIREN ACTIVATE AM 6000 POWER AX3700 PROTECT SIGNAL -10 dB NORMAL POWER FAULT AX 3700 CLIP AMP/LINE FAULT ALERT PILOT TONE ACTIVE 6 7 SPEAKER ZONE SELECT 120 Watts POWER I O 1 100V PA 2120 POWER CHANGEOVER SIGNAL -40 dB AMP. NUMBER 1 2 3 4 5 6 S/BY BUZZER ON / OFF 4 5 PA 2120 VOL CTRL ALL CALL audio DUTY AMP ZONE SELECTOR I CASS CD MAX MIXER SIG IN 12 E/M PANEL MAX 11 CH4 TUNER MIN SIG IN 10 CH3 OFF MAX 9 CH2 MIN MIN SIG IN 8 CH1 MX 2122 OVERRIDE 1 2 3 1 100V 6 s/by ZS 5121 6 audio + PT DUTY AMP SPEAKERS PA 2120 120 Watts POWER POWER PA 2120 I PROTECT O SIGNAL -10 dB CLIP 24V DC overriding 100V SIGNAL -40 dB packing information PA 2120 120 Watts POWER POWER PA 2120 I PROTECT O SIGNAL -10 dB CLIP SIGNAL -40 dB 100V STANDBY AMP rear view Carton : 555 (W) x 165 (H) x 295 (D) mm Weight : 4.2 kg Qty : 1 units / carton AUDIO SIGNAL INPUTS / OUTPUTS AX3700 AMP. AUTO FAULT CHANGE OVER Cascade AX3700 is more than 6 duty amps are installed CHANNEL 6 + - SIGNAL LINK INPUT OUTPUT G + - CHANNEL 5 INPUT OUTPUT LINK OPEN + - G + - CHANNEL 4 SIGNAL LINK + - G + CHANNEL 3 SIGNAL LINK INPUT OUTPUT LINK OPEN - INPUT OUTPUT LINK OPEN + - G + - SIGNAL LINK CHANNEL 2 INPUT OUTPUT LINK OPEN + - G + - SIGNAL LINK CHANNEL 1 OUTPUT LINK OPEN + - INPUT G + - STANDBY FAULT CONT. OUTPUT 3A NO MAX + - G INPUT SIGNAL DO NOT SWITCH TO LINK WHEN DIFFERENT AUDIO SOURCES ARE USED FOR THE ADJACENT CHANNEL CHAN. 1 ON CHAN. 2 ON CHAN. 3 ON CHAN. 4 ON CHAN. 5 ON SWITCH TO OFF FOR UNUSED CHANNEL AMPLIFIER 70/100V LINE INPUTS/OUTPUTS www.ampereselectronics.com 2009 : all rights reserved by amperes electronics sdn bhd CHANNEL / AMP. DETECTION SWITCHES CHAN. 6 ON HIGH CASCADE RS 485 LOW IN+ STANDBY AMP IN- IN- IN+ OUT+ CHANNEL 1 OUT- IN- IN+ OUT+ CHANNEL 2 OUT- IN+ IN- OUT+ CHANNEL 3 OUT- IN + IN - OUT - CHANNEL 4 OUT + IN+ IN- OUT+ CHANNEL 5 OUT- IN+ IN- OUT- OUT+ CHANNEL 6 DC 24V 0.5 A + - A B AMP CONNECTIONS IN +/- --> FR. AMP OUTPUTS OUT +/- --> TO ZONE SELECTOR / SPEAKERS MAX LOAD / CH - 400W / 100V LINE CASCADE CONNECT ONLY ONE WIRE FOR CASCADE TO NEXT UNIT UNIT 1(LOW) --- UNIT 2(HIGH) PLEASE OBSERVE POLARITY the emerging preference Page 18