Safety Relay H-462 General
Connections • Soldering pins for PCB, pre-soldered with Sn100
• 4 or 6 contacts • Forced guided contact set • According to EN 50205, application type A • Ambient temperature – 25 … + 80 °C • Soldering heat resistance 260 °C/5s • RoHS compliance • Signal relay according to UIC 736e
Technical Data mechanical
Dimensions L x W x H (in mm)
Technical Data electrical
Drive • Direct current or AC-current • Current controlled or bistable upon request Approvals • cULus • TÜV Standards • EN 50205 Size 1: Size 2:
57,8 x 20,5 x 48,6 67,4 x 20,5 x 48,6 10/10 g, 16 ms Half sinus 10/10 g, 10 – 55 Hz
Operating time NC-contact, contact opens Operating time NO-contact, contact closes Releasing time NO-contact, contact opens Releasing time NC-contact, contact closes
typical 17 ms typical 23 ms typical 5 ms typical 7 ms
Mechanical service life (without load) Weight
>10 7 cycles Size 1: 90 g Size 2: 115 g
Max. switching capacity Max. switching voltage Max. switching current Constant current Ith2 Constant current Ith2 at the same time over 2 contacts Constant current Ith2 at the same time over 3 contacts Constant current Ith2 at the same time over 4 contacts
AC 2.000 VA, DC *W AC 230/240 V, DC *V 10 A for deliveries from 2008 on: 10 A 10.0 A 10,0 A 10.0 A 8,4 A 7,3 A 10.0 A
AC-15 230/240 V DC-13 24 V
Ie = 4 A Ie = 2 A >10 5 cycles 10 A gL/gG-fuse
Electrical service life (with nominal load) Short-circuit capacity 1.000 A/AC 230 V * see DC-switching capacity Over voltage category (Ü) III Degree of pollution (V) 2 Insulating material group II Insulation between Contact – Contact Contactset – Drive
Dimensions
16
B-I = Basic insulation V-I = Reinforced (double) insulation
Nominal voltage network system AC 120/240 V AC 230/400 V V-l B-l V-l B-I
H-462 Size 1 (4 contacts)
Relay catalogue
• UL 508
Shock resistance NO-contact/NC-contact Vibration resistance NO-contact/NC-contact
Switching capacity
Insulation
• IEC 61810-1
Air-/ creeping distance > 3 mm > 3 mm
Test voltage 50Hz/60 s AC 2.500 V AC 2.500 V
H-462 Size 2 (6 contacts)
Safety Relay H-462 Type key
Housing 0 dustproof (RT II)
Connections 3 Soldering pins for PCB and sockets
Special version 4 Standard 3 2 screw caps M3 5 Code drill at yoke right side 6 Code drill at yoke left side
Version 00 Standard 01 Special version
H O Z - 0 3 4 6 2 / 1 4 - 0 0 1 3 1 6 - 3 1 0 / 0 8 1 . 0 0 Drive 0 DC neutral, monostable* 3 AC with Diode circuit 5 neutral, bistable
Size 1 4 contacts 2 6 contacts
NO-contact
Coils See coil table
NC-contact
Contactset-number See contactset table
CO-contact * Preferred version
AgCdO + 0,2 µm Au 080 079 077 078
Number of contacts N O / N C / C O - contacts 220 310 330 420
Contactset table
AgCdO + 5 µm Au 082 081 084 083
AgCdO AgSnO2 + 10 µm Au + 0,2 µm Au 061 088 059 087 057 058 055 086
AgSnO2 + 5 µm A 092 091 101 089
Contact material Contactset number
All values at ambient temperature Tu = 20 °C
DC-Coil table Number of contacts 310 220
Coil-No. 1228 1323 1316 1312 1311 1306 1303
Resistance R/Ω 33 110 480 1.700 2.700 10.000 40.000
Resistancetolerance± 5% 6% 8% 7% 7% 9% 12%
U1/V
U2/V
U3/V
Urück/V
3,4 6,2 13,9 27,3 34,4 69,8 139,8
11,6 21,2 43,9 82,9 104,4 199,7 395,0
11 19 42 83 104 205 394
0,8 1,4 3,0 5,9 7,4 14,7 28,2
U3/V
Urück/V
11 19 42 83 104 205 394
0,8 1,4 3,0 5,9 7,4 14,7 28,2
Printing Unom/V 6 12 24 48 60 110 220
All values at ambient temperature Tu = 20 °C Coil-No.
Number of contacts 420
1228 1323 1316 1312 1311 1306 1303 U 1: U 2: U 3: U rück:
Resistance R/Ω 33 110 480 1.700 2.700 10.000 40.000
Resistancetolerance ± 5% 6% 8% 7% 7% 9% 12%
U1/V
U2/V
3,7 6,9 15,5 30,3 38,2 77,8 155,7
11,6 21,2 43,9 82,9 104,4 199,7 395,0
Printing Unom/V 6 12 24 48 60 110 220
Minimum operating voltage with consideration of coil self heating Thermal restricted maximum coil voltage Maximum admissible coil voltage to realize a contact gap of > 0.5 mm also at a contact fault Releasing voltage
Further coils are possible and available
Relay catalogue
17
Safety Relay H-462 All values at ambient temperature Tu = 20 °C
DC-Coil table Number of contacts 330
Coil-No. 1228 1323 1316 1312 1268 1306 1303 U 1: U 2: U 3: U rück:
Resistance R/Ω 33 110 480 1.700 2.650 10.000 40.000
Resistancetolerance± 5% 6% 8% 7% 7% 9% 12%
U1/V
U2/V
U3/V
Urück/V
4,1 7,6 17,1 33,5 39,5 86,0 172,2
11,6 21,2 43,9 82,9 103,5 199,7 395,0
11 19 42 83 98 205 394
0,8 1,4 3,0 5,9 7,0 14,7 28,2
Printing Unom/V 6 12 24 48 60 110 220
Minimum operating voltage with consideration of coil self heating Thermal restricted maximum coil voltage Maximum admissible coil voltage to realize a contact gap of > 0.5 mm also at a contact fault Releasing voltage
Further coils are possible and available
All values at ambient temperature Tu = 20 °C
AC-Coil table Number of contacts 220 310 330 420
Coil-No. 1128 1323 1316 1514 1311 1306
Resistance ResistanceR/Ω tolerance ± 30 10% 110 10% 480 10% 750 10% 7.200 15% 10.000 15%
Umin/V
Umax/V
9,6 19,2 38,4 48,0 88,0 176,0
13,2 26,4 52,8 66,0 121,0 242,0
Printing Unom/V 12 24 48 60 110/115 220/230
Further coils are possible and available
Running types
Article-No. 462-1026 462-1027 462-1045 462-1140 462-1210 462-1312 462-1320 462-1326 462-1328 462-1333 462-1334 462-1342
18
Relay catalogue
Type key HOZ-03462/14-001316-220/080.00 HOZ-03462/14-001316-310/079.00 HOZ-03462/24-001316-330/077.00 HOZ-03462/14-001323-310/079.00 HOZ-03462/24-001316-420/078.00 HOZ-03462/24-001316-330/084.00 HOZ-03462/14-001316-310/081.00 HOZ-03462/14-001323-220/082.00 HOZ-03462/14-001312-220/082.00 HOZ-03462/24-001323-420/083.00 HOZ-03462/24-001316-420/083.00 HOZ-03462/24-001312-330/084.00
Printing Unom DC 24 V DC 24 V DC 24 V DC 12 V DC 24 V DC 24 V DC 24 V DC 12 V DC 48 V DC 12 V DC 24 V DC 48 V
U1/V 13,9 13,9 17,1 6,2 15,5 17,1 13,9 6,2 27,3 6,9 15,5 33,5
U2/V 43,9 43,9 43,9 21,2 43,9 43,9 43,9 21,2 82,9 21,2 43,9 82,9
U3/V 42 42 42 19 42 42 42 19 83 19 42 83
Urück/V 3,0 3,0 3,0 1,4 3,0 3,0 3,0 1,4 5,9 1,4 3,0 5,9
Safety Relay H-462 2 NO / 2 NC (220)
Connection grid Few on soldering side
3 NO / 1 NC (310)
Size 1
Inactive area 3 NO / 3 NC (330)
4 NO / 2 NC (420)
Size 2
Inactive area
Diagram current (A)
Contactgap:
current (A)
Arc duration
.
.
,1 0
Switching voltage
DC-switching capacity
0
switching cycles
Electrical service life
Relay catalogue
19
Safety Relays H-462 Accessories H-462/1 (4 contacts)
Socket
Removal tool
Article-No.: 462-8005 Sockets for PCB mounting
Article-No.: 462-8003 Socket
H-462/2 (6 contacts)
Sockets for conventional wiring
Article-No.: 462-8001 Removal tool
Article-No.: 462-8005
20
Relay catalogue
Safety Relay H-462 Accessories H-462/2 (6 contacts)
Sockets for PCB mounting
Article-No.: 462-8004
Sockets for conventional wiring
Article-No.: 462-8002
Base plate for dust protection and insulation strength: 2,5 kV
Article-No.: 462-8009
Relay catalogue
21