Preview only show first 10 pages with watermark. For full document please download

Ph02s Ph02d

   EMBED


Share

Transcript

,4 PH02S/D Sries 2W DC/DC CONVERTER, SIP-Package, 4:1 Ultra Wide Input Range FEATURES Š Efficiency up to 80% Š SIP Package with Standard Pinout Š Fully Regulated Output Š Operating Temperature Range -40°C to +85°C Š Ultra-wide 4:1 Input Range Š Isolation Voltage 1500 VDC Š Short circuit protection Š Lead free, RoHs compliant Š 3 Years Product Warranty The PH02S/D series are miniature, SIP Package, isolated 2W DC/DC converters with 1,500VDC isolation. The PH02S/D series features fully regulated output and wide 4:1 input voltage ranges. The most convenient advantage is the modules with a small footprint occupying only 2.4 cm2 (0.36 square in.) on the PCB. It offers short circuit protection and allows a wide operating temperature range of –40°C to +85°C. These isolated DC/DC converters are the latest offering from a world leader in power systems technology and manufacturing ― Delta Electronics, Inc Model List Model Number PH02S2403A PH02S2405A PH02S2412A PH02S2415A PH02D2405A PH02D2412A PH02D2415A PH02S4803A PH02S4805A PH02S4812A PH02S4815A PH02D4805A PH02D4812A PH02D4815A Input Voltage (Range) VDC 24 (9 ~ 36) 48 (18 ~ 75) Output Voltage VDC 3.3 5 12 15 ±5 ±12 ±15 3.3 5 12 15 ±5 ±12 ±15 Output Current Max. mA 500 400 167 134 ±200 ±83 ±67 500 400 167 134 ±200 ±83 ±67 Min. mA 125 100 42 33 ±50 ±21 ±17 125 100 42 33 ±50 ±21 ±17 Input Current @Max. Load mA(typ.) 97 110 106 105 114 108 106 49 58 54 54 60 55 55 @No Load mA(typ.) Reflected Ripple Current mA(typ.) 20 300 15 600 Max. capacitive Load uF 2200 1000 170 110 470* 100* 47* 2200 1000 170 110 470* 100* 47* Efficiency (typ.) @Max. Load % 71 76 79 80 73 77 79 70 72 78 78 70 76 76 * For each output DS_PH02S/D_03152012 E-mail: [email protected] http://www.delta.com.tw/dcdc P1 Input Characteristics Parameter Input Surge Voltage (1 sec. max.) Start-Up Voltage Under Voltage Shutdown Model Min. Typ. 24V Input Models -0.7 --- Max. 50 48V Input Models -0.7 --- 100 24V Input Models 48V Input Models 24V Input Models 48V Input Models 4.5 8.5 ----- 6 12 ----- 8.5 17 8 16 --- --- 0.5 A --- --- 1500 mW Reverse Polarity Input Current Short Circuit Input Power All Models Input Filter Internal Power Dissipation Unit VDC Capacitor type --- --- Min. --------------------- Typ. ±1.0 ±1.0 ±0.3 ±0.5 30 ----100 ±3 ±0.01 Continuous 2500 mW Output Characteristics Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20MHz) Ripple & Noise (20MHz) Ripple & Noise (20MHz) Transient Recovery Time Transient Response Deviation Temperature Coefficient Output Short Circuit Conditions Dual Output, Balanced Loads Vin=Min. to Max. Io=25% to 100% Over Line, Load & Temp. 25% Load Step Change Max. ±2.0 ±2.0 ±0.5 ±0.75 50 75 15 300 ±5 ±0.02 Unit % % % % mV P-P mV P-P mV rms uS % %/℃ General Characteristics Parameter I/O Isolation Voltage (rated) I/O Isolation Resistance I/O Isolation Capacitance Switching Frequency MTBF (Calculated) Conditions 60 Seconds 500 VDC 100KHz, 1V MIL-HDBK-217F@25℃, Ground Benign Min. 1500 1000 ----1,000,000 Typ. ----250 300 --- Max. ----500 ----- Unit VDC MΩ pF KHz Hours Recommended Input Fuse 24V Input Models 350mA Slow-Blow Type 48V Input Models 135mA Slow-Blow Type Remote On/Off Control Parameter Converter On Converter Off Standby Input Current Control Input Current ( on ) Control Input Current ( off ) Control Common Conditions Min. Typ. Max. Under 0.6 VDC or Open Circuit, drops down to 0VDC by 2mV/℃ 2.9 to 15 VDC --1 3 Vin = 0V -----1 Vin = 5.0V ----1 Referenced to Negative Input Unit mA mA mA Environmental Specifications Parameter Operating Temperature Range (with Derating) Case Temperature Storage Temperature Range Humidity (non condensing) Cooling Lead Temperature (1.5mm from case for DS_PH02S/D_03152012 Conditions Ambient Min. Max. -40 +85 --+90 -55 +105 --95 Free-Air convection --260 Unit ℃ ℃ ℃ % rel. H ℃ E-mail: [email protected] http://www.delta.com.tw/dcdc P2 Power Derating Curve 100 Natural convection Output Power (%) 80 100LFM 200LFM 60 400LFM 40 20 0 ~ -40 0 40 20 60 80 100 110 Ambient Temperature ] Notes 1 2 3 4 5 6 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. Ripple & Noise measurement bandwidth is 0-20 MHz. These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. All DC/DC converters should be externally fused at the front end for protection. Specifications subject to change without notice. Mechancial Drawing Mechanical Dimensions 0.5 [0.02] 2.00 [0.08] 2X2.54 [2X 0.10] [0.13] 0.5 [0.02] 3.2 12.45 [0.49] 25.95 [1.02] Pin Connections Pin Single Output 1 -Vin 2 +Vin Remote 3 6 +Vout 7 NC 8 NC 9 -Vout 3X 2.5 4 [3X 0.10] 7.62 [0.30] Dual Output -Vin +Vin Remote +Vout Common NC -Vout NC: No Connection 2 3 6 7 8 9 9.25 [0.36] 1 3.0 [0.12] Bottom View 0.25 [0.01] 24.95 [0.98] ►All dimensions in mm (inches) X.X±0.5 (X.XX±0.02) X.XX±0.25 ( X.XXX±0.01) ►Pins ±0.1(±0.004) ►Tolerance: 0.50 [0.0 2] Physical Outline Case Size : 25.95x9.25x12.45 mm (1.02x0.36x0.49 inches) Case Material Weight : : Non-Conductive Black Plastic (flammability to UL 94V-0 rated) 6.5g DS_PH02S/D_03152012 E-mail: [email protected] http://www.delta.com.tw/dcdc P3 Part Numbering System P H 02 S 24 05 A Form factor Family series Watt Number of Outputs Input Voltage Output Voltage Option Code D-DIP P-SIP S-SMD A~Z 01:1W 02:2W 03:3W 04:4W 06:6W 03:3.3V 05: 5V 12:12V 24: 24V 48:48V 03:3.3V 05: 5V 12:12V 15: 15V 24: 24V A - Std. Functions S - Single D- Dual WARRANTY Delta offers a three (3) years limited warranty. Complete warranty information is listed on our web site or is available upon request from Delta. Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice. DS_PH02S/D_03152012 E-mail: [email protected] http://www.delta.com.tw/dcdc P4