Preview only show first 10 pages with watermark. For full document please download

Philips Achieva 1.5 T A-series Tech Specs (technical Specifications)

   EMBED


Share

Transcript

Philips Achieva 1.5 T A-Series Tech Specs (Technical Specifications) Achieva 1.5T A-Series Gantry • Bore diameter/height of patient opening: 110: • Total bore length: 157: • Bore length with minimum opening: 60: • In-bore patient comfort features: Indirect lighting, adjustable airflow, 2-way headset, soft mattresses, head coil mirror, knee wedge cushion Gradient system • Name: Pulsar HP+ • Strength, z-axis, mT/m: 33 • Slew rate, z-axis, t/m/sec: 122 • Optional strength: 66 • Optional slew rate, t/m/sec: 180 • Cooling type: Liquid • Amplifier cooling type: Liquid Patient Table • Detachable: Trolley • Dimensions, L x W, cm: 240 x 53 • Horizontal speed, cm/sec: 2, 8, 18 • Elevating: Yes • Minimum height, cm: 52 • Load limit, kg: 250 (550) • Limited mobility: 250 (550) horizontal travel • Full mobility: 159 (350) vertical travel Planning and Installation • Overall gantry dimensions: 2.2 x 2.1 x 1.8 • Minimum ceiling height, m: 2.7 • Extent of fringe field: 3.8 x 2.4 • Total weight w/cooling, shielding, gradient/body coil: 4,795 kg (10,571 lbs) • Minimum dimensions of opening required for installation, W x H, m: 2.1 x 2.5 • Minimum installation area for magnet: 19.4 m2 • Minimum total installation area for system: 19.5 m2 • Total number of cabinets required: 3 • Line Voltage, VAC: 480 • Operational, kVa: 65 (system), 9 (cryocooler compressor) • Clinical Use: Whole body Acoustic Noise • Sound pressure level: • Reduction technology: Epoxy encapsulated body coil (electrical and mechanical), optimized cover design, headset (up to 25 dB), MR-compatible patient headset for in-gantry music, SofTone software (up to 30 dB), SENSE with fractional reduction factors by optimizing slew rates without penalty on scan time Achieva 1.5T A-Series Imaging Techniques • Echo Planar Imaging • Single shot • Multishot • EPI pulse sequences: MS-EPI, SS-EPI • Maximum EPI factor: 255 • Neurologic imaging • Perfusion • Diffusion weighted imaging • Diffusion tensor imaging(Optional) • Functional MRI(Optional) • Spectroscopy (Optional) • MRA • Time of flight • Peripheral • Bolus tracking • Interventional MR • Cardiac imaging • Cine • Coronary artery: Optional • Ecg gating: VCG • Motion compensation • Prospective respiratory gating • Maximum number of dimensions: 3 • Additional: Noncontrast angio • Clock speed, GHz: >2.6 • Operating system: Windows • Dedicated RAM: 8 GB • Maximum number of 256 x 256 slices per acquisition sequence: 1024 • Number of slices per sec: 1230 • Maximum matrix: 2048 x 2048 • Minimum slice thickness 2-D/3-D: 0.05 mm • Minimum FOV: 0.5 cm • Maximum FOV: 53 cm • Perfusion imaging (Optional) • fMRI (Optional) • Diffusion imaging • Diffusion tensor imaging (Optional) • Cardiac imaging (Optional) • Body imaging • 3-D image reconstruction System Integration • Modality worklist SCU • MR Image Storage SCU • Query/Retrieve SCU and SCP (SCU only) • Storage commitment SCU • Modality performed procedure step SCU • IHE profiles supported: MWL, PPS Control Console Workflow • Standard user interface: ExamCards • Operating system: Windows • Number of stored scanning protocols: 999 • Local hard disk capacity: 80 GB • RAM: 6 GB • Removable media: DVD • Image protocol sharing: NetForum • Features designed to enhance workflow: SmartExam, NetForum, SameScan, ExamCards, SENSE, Utilization Management RF Transmit and Receive • Power output, kW: 18 • Receiver bandwidth, kHz: 300 per channel • Amplifier type: Solid-state • Standard number of channels: 16 • Optional channel configurations: 32 • Location of coil connector: Gantry • Standard length of coil cables, m: 1.2 • Number of coil connectors: 3 • Coil tuning technique: Automatic • Name: Sense • Technique: Image-based • Clinical Technique: Automatic • Maximum parallel acquisition acceleration factor: 16 (varies by coil) Achieva 1.5T A-Series Magnet • Configuration: Short-bore cylindrical • Magnet Strength: 1.5 Tesla • Homogeneity, ppm V-RMS: 0.5 ppm at 50 cm, 0.2 ppm at 40 cm, 0.07 ppm at 30 cm, 0.03 ppm at 20 cm, 0.01 ppm at 10 cm • Dimensions of maximum useful FOV and homogeneity: 53 x 53 x 53 • Frequency drift, ppm/day: <2.4 • Shielding: Active • Main magnet shimming: Combination • Shimming: Patient-specific • Cryogen refill frequency: 3 years Other Achieva 1.5T A-Series Specifications • Other Attributes: Available in mobile configuration I/T; 63.87 MHz frequency; 215 cm maximum scam range; 51deg. viewing angle; 1.4% linearity at 53 cm DSV; direct digital sampling; 80 MHz sampling frequency; 23â?? monitor, 1900 x 1200 pixels monitor resolution; standard DICOM Enhanced MR; optional Ambient Experience. • FDA Clearance: Yes • CE Mark: Yes