Preview only show first 10 pages with watermark. For full document please download

Photometric Indoor Test Report

   EMBED


Share

Transcript

Photometric Indoor Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 Prepared For Elemental LED Inc, DBA Diode LED Wes Buck Suite 211,1195 Park Ave. Emeryville, CA 94608 United States Catalog Number SUNRISE™ 12V Light Bar DI-0202 Project Number 10461972 Test Number 748167 Test Date 2014-09-16 Prepared By Approved By Javier Caban, Technician Eric Gaudreau, Engineering Project Handler The results contained in this report pertain only to the tested sample. This report shall not be reproduced, except in full, without written approval of Underwriters Laboratories. Test Number 748167 - Page 1 of 6 Luminaire Description: Catalog Number: Lamp: Mounting: Ballast/Driver: Grey plastic housing, no enclosure SUNRISE™ 12V Light Bar DI-0202 30 white LEDs Surface One Meanwell LPV-60-12 Luminaire Test Conditions Test Temperature: Voltage: Current: Power: Power Factor: Frequency: Current THD: 24.6 120.0 0.06918 3.449 0.415 60 175 °C VAC A W Hz % Test Number 748167 - Page 2 of 6 INTENSITY(CANDLEPOWER) SUMMARY 180 ANGLE ALONG 0 84 5 81 120 10 80 15 78 20 76 25 73 30 70 35 66 90 40 61 45 56 50 50 55 44 60 37 65 30 70 23 75 16 60 80 9 85 3 90 0 150 ACROSS 45 ALONG 30 60 22.5 84 85 83 82 79 76 73 69 64 58 52 46 39 32 24 16 9 4 0 45 84 85 84 82 79 76 73 68 63 58 52 45 38 31 24 16 9 4 0 67.5 ACROSS 84 84 84 84 83 83 81 81 79 79 75 75 72 72 68 68 63 63 57 57 51 51 45 45 38 38 31 31 24 24 16 16 9 9 4 4 0 0 OUTPUT LUMENS 8 23 35 42 44 40 31 17 4 ZONAL LUMENS AND PERCENTAGES ZONE 0-30 0-40 0-60 0-90 40-90 60-90 90-180 0-180 90 0 30 LUMENS 66 108 192 245 136 52 0 245 % LUMINAIRE 26.87 44.19 78.63 100.00 55.81 21.37 0.00 100.00 EFFICACY (LUMENS PER WATT): 71.9 *** THIS IS AN ABSOLUTE TEST *** LUMINOUS LENGTH: 19.250 INS WIDTH: 0.375 INS LUMINANCE SUMMARY CD./SQ.M. ANGLE 45 55 65 75 85 ALONG 16852 16321 15292 13066 8499 45 17587 17004 15933 13580 9015 SC(ALONG): S/MH: 1.2, SC(ACROSS): ACROSS 17420 16853 15784 13491 9026 TESTED IN ACCORDANCE WITH IES PROCEDURES. Test Number 748167 - Page 3 of 6 1.3 1.3 INTENSITY(CANDLEPOWER) DATA IN 2.5 DEGREE STEPS ANGLE 0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 27.5 30.0 32.5 35.0 37.5 40.0 42.5 45.0 47.5 50.0 52.5 55.0 57.5 60.0 62.5 65.0 67.5 70.0 72.5 75.0 77.5 80.0 82.5 85.0 87.5 90.0 ALONG 84 81 81 80 80 79 78 77 76 75 73 72 70 68 66 63 61 58 56 53 50 47 44 40 37 34 30 27 23 19 16 12 9 6 3 1 0 22.5 84 85 85 84 83 83 82 81 79 78 76 75 73 71 69 66 64 61 58 55 52 49 46 42 39 35 32 28 24 20 16 13 9 6 4 2 0 PLANE 67.5 45 84 85 85 84 84 83 82 81 79 78 76 75 73 71 68 66 63 61 58 55 52 49 45 42 38 35 31 28 24 20 16 13 9 6 4 2 0 84 84 84 83 83 82 81 80 79 77 75 74 72 70 68 65 63 60 57 54 51 48 45 42 38 35 31 27 24 20 16 13 9 6 4 2 0 ACROSS 84 84 84 83 83 82 81 80 79 77 75 74 72 70 68 65 63 60 57 54 51 48 45 42 38 35 31 27 24 20 16 13 9 6 4 1 0 Test Number 748167 - Page 4 of 6 AVERAGE 84 84 84 83 83 82 81 80 79 77 76 74 72 70 68 65 63 60 57 54 51 48 45 42 38 35 31 27 24 20 16 13 9 6 4 1 0 OUTPUT LUMENS 8 23 35 42 44 40 31 17 4 COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE = .20 CC WALL 90 70 50 80 30 10 70 50 70 30 10 70 50 50 30 10 50 30 30 10 50 30 10 10 50 30 0 10 0 RCR 0 1.221.221.221.22 1.191.191.191.19 1.161.161.161.16 1.111.111.11 1.061.061.06 1.021.021.02 1.00 1 1.121.071.030.99 1.091.051.010.97 1.071.030.990.96 0.980.950.93 0.940.920.90 0.910.890.87 0.85 2 1.030.950.880.82 1.000.930.860.81 0.980.910.850.80 0.870.820.78 0.840.800.76 0.810.780.75 0.73 3 0.940.830.750.68 0.920.820.740.68 0.890.800.730.67 0.770.710.66 0.750.690.65 0.720.680.64 0.62 4 0.870.740.650.59 0.850.730.650.59 0.820.720.640.58 0.690.630.57 0.670.610.57 0.650.600.56 0.54 5 0.800.670.570.50 0.780.650.570.50 0.750.640.560.50 0.620.550.50 0.600.540.49 0.580.530.48 0.46 6 0.740.600.500.44 0.720.590.500.44 0.700.580.490.43 0.560.480.43 0.540.480.43 0.530.470.42 0.40 7 0.670.530.440.38 0.660.520.440.38 0.640.520.430.37 0.500.420.37 0.480.420.37 0.470.410.37 0.35 8 0.620.480.400.34 0.610.470.390.33 0.590.470.390.33 0.450.380.33 0.440.370.33 0.430.370.32 0.31 9 0.580.440.350.29 0.560.430.350.29 0.550.430.350.29 0.410.340.29 0.400.330.29 0.390.330.28 0.27 10 0.530.400.310.26 0.520.390.310.26 0.510.390.310.26 0.380.310.26 0.370.300.25 0.360.300.25 0.24 THE ABOVE COEFFICIENTS HAVE BEEN CALCULATED BASED ON LUMINAIRE LUMENS BECAUSE IN AN ABSOLUTE TEST THE BARE LAMP LUMENS ARE UNKNOWN. LIGHTING DESIGN CALCULATIONS MADE USING THESE COEFFICIENTS SHOULD THEREFORE USE THE LUMINAIRE LUMENS IN THE CALCULATION FORMULA LABORATORY RESULTS MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE. BALLAST AND FIELD FACTORS HAVE NOT BEEN APPLIED. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE. Test Number 748167 - Page 5 of 6 Cone of Light Cone Of Light Tabulation Mounting Height (Feet) Footcandles at Nadir Diameter (Feet) 4.00 5.27 5.10 6.00 2.34 7.64 8.00 1.32 10.2 10.0 0.844 12.7 12.0 0.586 15.3 14.0 0.431 17.8 16.0 0.330 20.4 Cone of Light Plot Test Number 748167 - Page 6 of 6