Preview only show first 10 pages with watermark. For full document please download

Photometric Outdoor Test Report - Revolution Lighting Technologies

   EMBED


Share

Transcript

Photometric Outdoor Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 Prepared For Relume Technologies Debbie Jones 1795 North Lapeer Road Oxford, MI 48371 Catalog Number UAG2-F24-D5-CW (w/ globe) Project Number 10007993 Test Number 154190 Test Date 2013-04-19 Prepared By Approved By Jeff Smith Jr., Project Coordinator Eric Gaudreau, Project Coordinator The results contained in this report pertain only to the tested sample. This report shall not be reproduced, except in full, without written approval of Underwriters Laboratories. Test Number 154190 - Page 1 of 15 Luminaire Description: Catalog Number: Lamp: Mounting: Ballast/Driver: Cast aluminum housing, extruded aluminum heatsinks, formed specular aluminum reflectors, clear prismatic plastic enclosure with linear prismatic top UAG2-F24-D5-CW (w/ globe) 24 white LEDs Post Top One Philips Advance LED-INTA-700C-140-F30 Luminaire Test Conditions Test Temperature: Voltage: Current: Power: Power Factor: Frequency: Current THD: 25.5 120.0 0.2487 29.15 0.977 60 14.8 °C VAC A W Hz % Test Number 154190 - Page 2 of 15 *** THIS IS AN ABSOLUTE TEST REPORT *** UTILIZATION TABLE CO-EFFICIENT OF UTILIZATION RATIO HOUSE SIDE 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 5.0 TOTAL: STREET SIDE TOTAL 0.062 0.121 0.170 0.206 0.231 0.248 0.264 0.272 0.287 0.062 0.121 0.171 0.210 0.236 0.254 0.270 0.279 0.295 0.125 0.242 0.340 0.416 0.466 0.501 0.534 0.551 0.582 0.351 0.364 0.715 PERCENTAGE OUTPUTS DOWNWARD: UPWARD: STREET SIDE = 36.4% HOUSE SIDE = 35.1% TOTAL = 71.5% STREET SIDE = 14.2% HOUSE SIDE = 14.3% TOTAL = 28.5% EFFICACY (LUMENS PER WATT) 80.2 THE ABOVE COEFFICIENTS HAVE BEEN CALCULATED BASED ON LUMINAIRE LUMENS BECAUSE IN AN ABSOLUTE TEST THE BARE LAMP LUMENS ARE UNKNOWN. LIGHTING DESIGN CALCULATIONS MADE USING THESE COEFFICIENTS SHOULD THEREFORE USE THE LUMINAIRE LUMENS IN THE CALCULATION FORMULA Test Number 154190 - Page 3 of 15 727$/ LUMINAIRE OUTPUT: IESNA CUTOFF CLASSIFICATION: 2333 Lms. NON-CUTOFF ZONAL LUMEN SUMMARY PER IES PUBLICATION TM-15-07 *** THIS IS AN ABSOLUTE TEST REPORT *** FORWARD LIGHT: LUMENS 848.7 % LUMENS FORWARD FORWARD FORWARD FORWARD 36.4 % LOW ZONE (0 TO 30 DEGREES) MID ZONE (30 TO 60 DEGREES) HIGH ZONE (60 TO 80 DEGREES) VERY HIGH ZONE (80 TO 90 DEGREES) 1.3 9.8 16.0 9.3 % % % % BACK LIGHT: LUMENS 819.9 % LUMENS BACK BACK BACK BACK LIGHT LIGHT LIGHT LIGHT 35.1 % LOW ZONE (0 TO 30 DEGREES) MID ZONE (30 TO 60 DEGREES) HIGH ZONE (60 TO 80 DEGREES) VERY HIGH ZONE (80 TO 90 DEGREES) 1.4 9.8 15.2 8.8 % % % % UPLIGHT: LUMENS 664.1 % LUMENS 28.5 % UPLIGHT LOW ZONE (90 TO 100 DEGREES) UPLIGHT HIGH ZONE (100 TO 180 DEGREES) TRAPPED LIGHT: NOT APPLICABLE TO AN ABSOLUTE TEST Test Number 154190 - Page 4 of 15 14.5 % 14.0 % IES "BUG" RATING (BACK LIGHT, UPLIGHT, GLARE) PER IES TM-15-11 SECONDARY SOLID ANGLE RATING LUMENS BACK LIGHT BH (60-80 DEGREES) BM (30-60 DEGREES) BL (0-30 DEGREES) 355.3 227.9 31.8 B 1 B 1 B 0 325.7 338.4 U 3 U 3 217.0 205.0 373.0 355.3 G G G G UPLIGHT UH (100-180 DEGREES) UL (90-100 DEGREES) GLARE LIGHT FVH (80-90 DEGRESS) BVH (80-90 DEGRESS) FH (60-80 DEGREES) BH (60-80 DEGRESS) IES BUG RATING: B1 U3 2 2 0 0 G2 LABORATORY RESULTS MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE. BALLAST FACTORS HAVE NOT BEEN APPLIED TESTED IN 30 PLANES LEFT SIDE, 30 PLANES RIGHT SIDE, LEFT AND RIGHT AVERAGED VERTICAL TEST INCREMENTS ARE 2.5 DEGREES. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE Test Number 154190 - Page 5 of 15 INTENSITY(CANDLEPOWER) IN MAX. PLANE INTENSITY(CANDLEPOWER) IN MAX. CONE ANGLE ANGLE 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 52.5 55.0 57.5 60.0 62.5 65.0 67.5 70.0 72.5 75.0 77.5 80.0 82.5 85.0 87.5 90.0 95.0 105.0 115.0 125.0 135.0 145.0 155.0 165.0 175.0 180.0 CANDLEPOWER 32 32 45 57 67 86 103 118 143 163 223 237 271 301 295 326 360 384 366 390 366 453 394 430 425 400 343 336 128 49 42 53 44 44 31 28 29 150 180 150 0.0 5.0 15.0 25.0 35.0 45.0 55.0 60.0 62.5 65.0 67.5 70.0 72.5 75.0 77.5 80.0 82.5 85.0 87.5 90.0 95.0 105.0 115.0 125.0 135.0 145.0 155.0 165.0 175.0 180.0 120 120 90 90 300 60 60 600 30 0 30 MAXIMUM INTENSITY(CANDLEPOWER): 453 CD PLANE OF MAXIMUM: 0.0 VERTICAL ANGLE OF MAXIMUM: Test Number 154190 - Page 6 of 15 77.5 CANDLEPOWER 453 414 375 363 353 378 388 380 372 371 371 369 362 365 371 379 378 380 392 386 383 366 377 355 338 347 355 349 351 357 INTENSITY(CANDLEPOWER) TABULATION HORIZONTAL ANGLE VERT. ANGLE 0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 27.5 30.0 32.5 35.0 37.5 40.0 42.5 45.0 47.5 50.0 52.5 55.0 57.5 60.0 62.5 65.0 67.5 70.0 72.5 75.0 77.5 80.0 82.5 85.0 87.5 90.0 0.0 5.0 15.0 25.0 35.0 45.0 55.0 60.0 62.5 65.0 32 32 32 39 45 54 57 63 67 79 86 96 103 113 118 130 143 150 163 186 223 237 271 301 295 326 360 384 366 390 366 453 394 430 425 400 343 32 31 33 42 47 55 57 62 70 78 87 95 102 111 119 130 139 151 162 191 225 247 273 284 294 346 360 372 362 393 354 414 397 399 417 421 342 32 31 35 42 49 56 58 63 68 75 85 93 106 113 121 131 136 148 162 192 228 236 279 297 312 349 353 371 365 388 346 375 410 424 393 393 345 32 31 36 43 50 54 59 62 67 76 83 95 104 114 123 133 140 145 161 189 224 235 281 305 318 332 341 392 373 397 372 363 438 430 397 408 357 32 32 35 42 51 53 58 63 69 77 85 94 103 113 123 128 138 148 165 192 221 242 284 289 308 322 337 365 379 387 360 353 434 410 397 406 352 32 32 35 43 50 55 58 63 72 78 88 95 102 110 121 130 142 157 167 193 216 248 283 277 305 321 362 366 376 389 384 378 436 389 418 416 370 32 32 36 45 49 54 60 64 71 78 86 95 102 112 122 132 141 152 169 190 219 249 286 291 317 327 355 371 387 393 364 388 441 382 414 434 373 32 32 36 45 50 53 60 64 70 77 85 94 107 116 126 133 138 149 169 195 226 244 286 293 329 325 344 374 394 401 357 380 417 375 406 413 360 32 32 35 45 51 54 60 64 70 77 85 94 108 115 125 131 137 147 166 195 221 236 280 294 331 330 338 368 384 380 351 372 404 372 406 405 348 32 32 36 45 51 55 60 64 69 77 86 96 109 117 124 133 143 148 167 197 225 234 277 303 333 331 336 361 378 364 346 371 407 375 400 408 351 VALUES SHOWN ARE THE AVERAGES FOR THE TWO SIDES OF THE LUMINAIRE Test Number 154190 - Page 7 of 15 INTENSITY(CANDLEPOWER) TABULATION CONTINUED HORIZONTAL ANGLE VERT. ANGLE 0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 27.5 30.0 32.5 35.0 37.5 40.0 42.5 45.0 47.5 50.0 52.5 55.0 57.5 60.0 62.5 65.0 67.5 70.0 72.5 75.0 77.5 80.0 82.5 85.0 87.5 90.0 67.5 70.0 72.5 75.0 77.5 80.0 82.5 85.0 87.5 90.0 32 32 36 45 51 56 60 65 70 78 86 96 111 117 124 134 143 149 168 201 229 236 271 308 328 327 327 371 385 359 347 371 401 395 401 411 354 32 32 36 45 51 55 60 65 70 78 87 96 108 117 125 132 142 149 170 201 235 238 273 308 329 320 319 375 387 370 351 369 399 405 395 409 355 32 32 36 46 52 54 60 65 71 77 86 95 106 115 125 135 145 149 167 195 229 238 272 309 334 323 319 383 393 363 354 362 382 395 375 405 346 32 32 37 45 52 54 61 65 72 79 86 96 107 116 124 134 145 151 169 196 230 237 270 306 330 326 316 376 394 371 355 365 383 392 363 401 341 32 32 38 46 52 55 62 64 72 79 86 96 106 112 125 134 144 150 167 192 228 235 273 296 327 319 318 363 374 371 355 371 374 383 361 398 344 32 32 37 46 52 55 61 64 73 78 87 95 104 113 123 134 141 148 166 189 223 233 271 296 317 318 324 359 375 367 348 379 374 392 371 402 347 32 32 38 46 52 56 60 65 73 78 88 95 106 113 124 135 141 150 167 189 228 238 275 293 309 320 335 362 379 367 344 378 363 388 376 413 351 32 33 38 47 52 55 59 66 72 79 90 94 104 111 125 134 141 155 167 191 225 246 280 290 308 324 345 361 375 375 350 380 353 388 389 413 345 32 33 38 48 51 55 59 66 72 81 89 94 104 109 123 132 141 152 166 189 224 251 280 286 305 326 338 353 368 376 368 392 351 392 392 408 351 32 33 39 47 51 56 60 66 72 80 88 95 104 111 121 134 143 152 166 190 219 254 274 281 295 326 339 353 370 376 376 386 357 393 389 407 353 VALUES SHOWN ARE THE AVERAGES FOR THE TWO SIDES OF THE LUMINAIRE Test Number 154190 - Page 8 of 15 INTENSITY(CANDLEPOWER) TABULATION CONTINUED HORIZONTAL ANGLE VERT. ANGLE 0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 27.5 30.0 32.5 35.0 37.5 40.0 42.5 45.0 47.5 50.0 52.5 55.0 57.5 60.0 62.5 65.0 67.5 70.0 72.5 75.0 77.5 80.0 82.5 85.0 87.5 90.0 95.0 105.0 115.0 125.0 135.0 145.0 155.0 165.0 175.0 180.0 32 34 40 46 51 57 59 63 73 78 89 95 104 114 124 131 143 156 166 192 222 261 268 283 305 329 342 352 367 378 360 383 358 401 387 413 368 32 35 39 47 55 54 60 63 70 76 87 97 108 116 123 130 140 149 167 189 219 246 276 304 313 311 314 347 369 357 335 366 354 366 380 389 357 32 34 38 48 53 57 60 65 71 78 88 97 110 114 123 134 142 147 168 189 211 234 274 311 312 310 296 357 389 380 354 377 351 382 374 369 361 32 34 39 49 53 57 62 65 72 81 89 97 106 117 122 135 145 153 161 183 225 246 264 296 308 321 314 356 369 387 360 355 357 381 370 373 373 32 34 39 46 53 57 60 67 73 82 89 95 104 117 124 136 148 147 158 186 229 254 266 282 293 333 320 341 356 392 380 338 351 381 396 396 382 32 34 40 45 53 57 61 65 73 79 89 95 108 117 123 135 142 148 165 189 229 245 263 296 304 316 305 342 367 408 354 347 343 351 395 376 384 32 33 40 47 54 55 61 65 72 79 87 99 109 118 126 139 137 146 166 196 225 242 280 312 308 314 292 351 385 401 337 355 344 362 396 381 376 32 33 40 47 51 56 60 66 72 79 88 99 109 115 126 136 142 147 171 197 220 249 279 293 309 305 283 344 363 396 336 349 354 353 390 390 385 32 33 39 47 51 57 59 67 73 81 89 97 104 113 125 136 142 154 168 189 216 257 269 276 300 324 291 331 354 411 353 351 332 340 383 421 379 32 34 39 51 53 59 60 70 74 83 88 98 106 115 133 133 143 153 169 200 220 272 266 279 308 321 283 324 359 411 311 357 330 290 374 415 351 VALUES SHOWN ARE THE AVERAGES FOR THE TWO SIDES OF THE LUMINAIRE Test Number 154190 - Page 9 of 15 UPLIGHT INTENSITY(CANDLEPOWER) TABULATION HORIZONTAL ANGLE VERT. ANGLE 90.0 92.5 95.0 97.5 100.0 102.5 105.0 107.5 110.0 112.5 115.0 117.5 120.0 122.5 125.0 127.5 130.0 132.5 135.0 137.5 140.0 142.5 145.0 147.5 150.0 152.5 155.0 157.5 160.0 162.5 165.0 167.5 170.0 172.5 175.0 177.5 180.0 0.0 5.0 15.0 25.0 35.0 45.0 55.0 60.0 62.5 65.0 343 388 336 295 238 186 128 73 61 54 49 45 42 42 42 43 46 49 53 54 52 47 44 38 35 32 31 29 28 28 28 28 28 29 30 30 29 342 382 326 270 236 176 119 73 59 53 48 44 42 42 42 44 47 51 53 54 51 46 43 38 34 32 30 29 28 28 28 28 28 29 30 29 29 345 369 315 277 236 179 115 77 59 53 48 44 42 42 41 42 44 49 52 52 50 47 43 39 35 32 30 29 28 28 28 28 28 29 30 29 29 357 363 310 290 235 175 122 81 60 53 48 44 42 41 41 41 44 48 50 51 52 48 43 39 35 32 30 29 28 28 28 28 28 29 30 30 29 352 375 312 265 233 174 123 82 61 53 48 44 42 41 41 41 45 50 53 54 51 46 42 37 34 31 30 28 28 28 28 28 28 29 30 30 29 370 393 310 268 234 174 120 88 62 53 48 45 42 41 40 41 46 51 53 52 50 49 41 36 33 31 30 28 27 28 28 28 29 29 30 30 29 373 380 319 277 247 180 127 95 62 53 48 44 42 41 41 42 46 48 50 49 48 47 41 36 33 31 29 28 28 28 28 28 29 29 30 30 29 360 369 303 275 240 174 124 93 61 52 47 44 42 40 40 41 43 47 48 49 49 46 41 37 33 31 29 28 28 28 28 28 29 29 30 30 29 348 360 301 272 239 172 115 91 61 52 47 44 41 40 40 41 43 46 48 50 48 44 41 37 33 31 29 28 28 28 28 28 29 29 30 30 29 351 361 303 273 240 177 134 93 61 52 47 44 41 41 41 41 43 45 47 48 46 44 40 36 33 31 30 28 28 28 28 28 29 29 30 30 29 VALUES SHOWN ARE THE AVERAGES FOR THE TWO SIDES OF THE LUMINAIRE Test Number 154190 - Page 10 of 15 UPLIGHT INTENSITY(CANDLEPOWER) TABULATION HORIZONTAL ANGLE VERT. ANGLE 90.0 92.5 95.0 97.5 100.0 102.5 105.0 107.5 110.0 112.5 115.0 117.5 120.0 122.5 125.0 127.5 130.0 132.5 135.0 137.5 140.0 142.5 145.0 147.5 150.0 152.5 155.0 157.5 160.0 162.5 165.0 167.5 170.0 172.5 175.0 177.5 180.0 67.5 70.0 72.5 75.0 77.5 80.0 82.5 85.0 87.5 90.0 354 363 302 280 240 176 138 92 61 52 47 44 41 40 40 41 43 45 46 47 47 45 41 36 33 31 29 28 28 28 28 28 29 29 30 30 29 355 359 306 285 241 175 139 92 61 52 48 44 41 40 40 41 43 45 47 48 50 43 41 36 33 30 29 28 28 28 28 28 29 29 30 30 29 346 346 300 280 235 173 141 92 62 52 48 44 42 40 40 41 43 45 47 47 46 42 40 36 33 30 29 28 27 28 28 28 29 29 30 30 29 341 330 301 279 242 182 142 92 62 52 48 44 41 40 40 41 42 45 47 49 47 42 39 36 32 30 29 28 27 28 28 28 29 29 30 30 29 344 325 306 277 240 185 142 92 62 52 48 44 41 40 40 40 42 45 47 50 47 43 38 35 32 30 29 28 27 28 28 28 28 29 30 30 29 347 328 316 276 238 188 138 91 62 52 48 44 41 40 40 40 42 44 48 49 46 43 38 35 32 30 29 28 27 27 28 28 29 29 30 30 29 351 332 318 268 234 192 138 93 62 52 47 44 41 40 39 39 41 45 49 50 47 44 38 35 32 30 29 28 27 27 28 28 29 29 30 30 29 345 332 317 270 242 195 138 92 62 52 47 44 41 39 39 39 41 44 49 50 47 43 38 35 32 30 29 28 27 27 28 28 29 29 30 30 29 351 336 313 270 246 196 138 94 63 52 47 43 41 39 39 39 42 45 49 49 47 42 38 34 31 30 29 28 27 27 28 28 29 29 30 30 29 353 339 305 274 246 197 140 96 63 52 47 43 40 39 38 39 43 46 47 47 45 42 38 34 32 30 29 28 27 27 28 28 29 29 30 30 29 VALUES SHOWN ARE THE AVERAGES FOR THE TWO SIDES OF THE LUMINAIRE Test Number 154190 - Page 11 of 15 UPLIGHT INTENSITY(CANDLEPOWER) TABULATION HORIZONTAL ANGLE VERT. ANGLE 90.0 92.5 95.0 97.5 100.0 102.5 105.0 107.5 110.0 112.5 115.0 117.5 120.0 122.5 125.0 127.5 130.0 132.5 135.0 137.5 140.0 142.5 145.0 147.5 150.0 152.5 155.0 157.5 160.0 162.5 165.0 167.5 170.0 172.5 175.0 177.5 180.0 95.0 105.0 115.0 125.0 135.0 145.0 155.0 165.0 175.0 180.0 368 338 300 273 253 200 146 95 62 52 47 43 40 39 38 39 42 44 46 47 47 42 39 34 32 30 29 28 27 27 28 28 29 30 30 30 29 357 331 313 283 250 202 156 96 63 52 46 43 40 39 38 38 39 40 42 46 43 41 38 35 32 30 29 28 27 28 28 28 29 30 30 29 29 361 337 313 293 244 213 162 105 66 52 47 43 40 39 38 37 37 38 41 42 42 40 36 34 32 29 28 27 27 27 28 28 29 30 30 30 29 373 335 326 289 247 211 160 108 66 52 47 43 40 39 37 37 37 38 42 44 46 39 35 33 31 29 28 27 27 27 28 28 29 30 30 29 29 382 340 305 290 247 213 159 112 71 52 47 43 40 38 37 36 36 39 42 44 42 38 34 31 30 28 27 27 27 27 28 28 29 30 30 30 29 384 326 300 282 248 212 162 118 74 52 47 43 40 38 37 36 37 41 38 38 38 36 33 31 29 29 28 27 27 27 28 28 29 30 30 29 29 376 328 290 284 246 225 157 120 75 52 47 43 40 38 37 36 36 36 36 36 36 34 32 30 29 28 28 28 27 27 28 28 29 30 30 29 29 385 340 297 295 245 218 172 123 78 53 47 43 40 37 36 36 35 36 36 37 36 34 32 30 29 28 28 27 27 27 28 28 29 30 30 29 29 379 312 294 277 233 204 173 116 79 53 47 43 40 38 36 35 34 35 38 41 39 35 32 29 27 27 27 27 27 27 28 28 29 30 30 29 29 351 292 292 261 221 194 163 105 73 51 46 42 39 37 35 34 34 35 40 41 37 35 31 29 27 27 27 27 27 27 28 28 29 30 30 29 29 VALUES SHOWN ARE THE AVERAGES FOR THE TWO SIDES OF THE LUMINAIRE Test Number 154190 - Page 12 of 15 VERT. ANGLE 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 55.0 60.0 65.0 70.0 75.0 77.5** 80.0 85.0 90.0 INTENSITY(CANDLEPOWER) SUMMARY 0.0 **** 32 32 45 57 67 86 103 118 143 163 223 271 295 360 366 366 453 394 425 343 90.0 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 55.0 60.0 65.0 70.0 75.0 77.5** 80.0 85.0 90.0 32 39 51 60 72 88 104 121 143 166 219 274 295 339 370 376 386 357 389 353 5.0 15.0 32 33 47 57 70 87 102 119 139 162 225 273 294 360 362 354 414 397 417 342 32 35 49 58 68 85 106 121 136 162 228 279 312 353 365 346 375 410 393 345 HORIZONTAL ANGLES - STREET SIDE 25.0 35.0 45.0 55.0 65.0 75.0 32 36 50 59 67 83 104 123 140 161 224 281 318 341 373 372 363 438 397 357 32 35 51 58 69 85 103 123 138 165 221 284 308 337 379 360 353 434 397 352 32 35 50 58 72 88 102 121 142 167 216 283 305 362 376 384 378 436 418 370 32 36 49 60 71 86 102 122 141 169 219 286 317 355 387 364 388 441 414 373 32 36 51 60 69 86 109 124 143 167 225 277 333 336 378 346 371 407 400 351 32 37 52 61 72 86 107 124 145 169 230 270 330 316 394 355 365 383 363 341 85.0 32 38 52 59 72 90 104 125 141 167 225 280 308 345 375 350 380 353 389 345 HORIZONTAL ANGLES - HOUSE SIDE 95.0 105.0 115.0 125.0 135.0 145.0 155.0 165.0 175.0 180.0 32 40 51 59 73 89 104 124 143 166 222 268 305 342 367 360 383 358 387 368 32 39 55 60 70 87 108 123 140 167 219 276 313 314 369 335 366 354 380 357 32 38 53 60 71 88 110 123 142 168 211 274 312 296 389 354 377 351 374 361 32 39 53 62 72 89 106 122 145 161 225 264 308 314 369 360 355 357 370 373 32 39 53 60 73 89 104 124 148 158 229 266 293 320 356 380 338 351 396 382 32 40 53 61 73 89 108 123 142 165 229 263 304 305 367 354 347 343 395 384 32 40 54 61 72 87 109 126 137 166 225 280 308 292 385 337 355 344 396 376 32 40 51 60 72 88 109 126 142 171 220 279 309 283 363 336 349 354 390 385 32 39 51 59 73 89 104 125 142 168 216 269 300 291 354 353 351 332 383 379 32 39 53 60 74 88 106 133 143 169 220 266 308 283 359 311 357 330 374 351 ** DENOTES VERTICAL ANGLE OF MAXIMUM CONE **** DENOTES LATERAL ANGLE OF MAXIMUM PLANE INTENSITY WAS MEASURED IN 2.5 DEGREE STEPS - TABULATIONS ARE AVAILABLE Test Number 154190 - Page 13 of 15 ** ILLUMINANCE(FOOTCANDLE) TABLE FOR SINGLE LUMINAIRE AT 14.0 FT. ** LATERAL RATIOS -3.00 + + + + + + + + + + + + + + + .063 .061 .056 .045 .035 .028 .022 .017 .014 .011 .009 .007 .006 .005 .004 | -2.50 + + + + + + + + + + + + + + + .087 .087 .081 .068 .054 .040 .028 .021 .016 .013 .010 .008 .007 .005 .005 | -2.00 + + + + + + + + + + + + + + + 0.14 0.12 0.10 .091 .069 .052 .036 .026 .020 .015 .011 .009 .007 .006 .005 | -1.50 + + + + + + + + + + + + + + + 0.23 0.23 0.18 0.12 .093 .066 .044 .030 .022 .016 .012 .009 .007 .006 .005 | -1.00 + + + + + + + + + + + + + + + 0.30 0.30 0.26 0.18 0.11 .082 .051 .032 .024 .018 .013 .010 .008 .006 .005 | -0.50 + + + + + + + + + + + + + + + 0.34 0.35 0.29 0.23 0.13 .089 .057 .037 .026 .019 .014 .010 .008 .007 .006 HOUSE | CURB LINE -------- + -- + -- + -- + -- + -- + -- + -- + -- + -- + -- + -- + -- + -- + -- + -STREET0.16 0.33 0.30 0.24 0.15 .094 .060 .040 .028 .020 .014 .011 .008 .007 .006 | 0.50 + + + + + + + + + + + + + + + 0.33 0.34 0.30 0.24 0.13 .091 .057 .036 .026 .019 .014 .010 .008 .007 .005 | 1.00 + + + + + + + + + + + + + + + 0.29 0.30 0.27 0.18 0.12 .083 .051 .034 .024 .018 .014 .010 .008 .007 .005 | 1.50 + + + + + + + + + + + + + + + 0.25 0.23 0.18 0.14 .098 .069 .044 .029 .022 .017 .013 .010 .008 .006 .005 | 2.00 + + + + + + + + + + + + + + + 0.15 0.14 0.12 .097 .072 .053 .036 .026 .020 .015 .012 .010 .008 .006 .005 | 2.50 + + + + + + + + + + + + + + + .099 .092 .080 .067 .052 .040 .029 .023 .018 .014 .011 .009 .007 .006 .005 | 3.00 + + + + + + + + + + + + + + + .062 .060 .055 .046 .036 .029 .023 .019 .016 .013 .010 .008 .006 .005 .004 | 3.50 + + + + + + + + + + + + + + + .040 .037 .034 .031 .026 .021 .018 .016 .014 .012 .009 .007 .006 .005 .004 | 4.00 + + + + + + + + + + + + + + + .029 .027 .024 .022 .019 .017 .015 .013 .012 .010 .008 .006 .005 .004 .004 | 4.50 + + + + + + + + + + + + + + + .024 .021 .019 .017 .016 .014 .013 .011 .010 .008 .007 .005 .005 .004 .003 | 5.00 + + + + + + + + + + + + + + + .016 .015 .015 .014 .013 .012 .011 .009 .008 .007 .006 .005 .004 .004 .003 | 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 LONGITUDINAL MOUNTING HEIGHT RATIOS CORRECTION FACTORS FOR OTHER MOUNTING HEIGHTS: SEE ISOFOOTCANDLE PAGE Test Number 154190 - Page 14 of 15 MOUNTING HEIGHT FOR ISOFC 14.0 FEET 3 H O U S E Mounting HT. 7.50 10.00 12.50 14.00 20.00 25.00 30.00 2 Multiplier - FEET - 3.48 - 1.96 - 1.25 - 1.00 - 0.49 - 0.31 - 0.22 1 COEFFICIENT OF UTILIZATION DASHED CURVES CURB LINE S T R E E T 0.1 0.2 0.3 0.4 0.5 0.6 1 0.20 2 0.10 3 0.05 4 5 0.01 0.02 0 RATIO = 1 DISTANCE ALONG MOUNTING HEIGHT 2 3 0.01 0.02 0.05 0.1 0.2 0.5 1 2 5 4 10 20 50 100 200 500 1000 2000 5000 Test Number 154190 - Page 15 of 15 5 10000 20000 50000 6 7