Transcript
SPECIFICATION SHEET
PIK SERIES INSERT HB0032
Especially designed to be installed in custom hood for use over residential commercial-style cooking surfaces. A complete installation requires several optional components. Refer to page 2 when planning your installation. FEATURES
• • • • • •
Cabinet mount _ custom application Widths: 33’’, 45’’ Halogen lighting (33’’_ 2 x 50 watt; 45’’_ 3 x 50 watt PAR20) lamps not included Slide controls: Lighting, on-off, infinite speed Easily accessible, dishwasher-safe stainless steel baffle filters Heat Sentry™ turns blower ON to HIGH speed when excess heat is detected
Mount insert so bottom of custom hood is 24’’ to 30’’ above cooking surface. Custom Hood Liner L33 or L45 Series
Ambient Light Panel ALP Series
4”
Ad j inal (S ust nom 0” 6 hood sh ee able tom ”, 48” or s ee lin d u c t f er ep Fits 36”, 42 or sp th th de ec wid ta ils )
HA0027A
Backsplash RMP Series
WCPI Remote Control 10 ”
6 3/8''
4”
OPTIONS • Custom hood liners (L33 or L45 Series): Widths - 36’’, 42’’, 48’’ and 60’’ Adjustable depth - see liner spec. sheet for details Stainless Steel construction - protects custom hood base and wipes clean easily • Ambient light panel (ALP Series) for L Series custom hood liners (Halogen lighting: 36’’ and 42’’_ 2 x 50 watt; 48” and 60” _ 3 x 50 watt GU10) Lamps included • Backsplash (RMP Series): Widths - 36”, 42”, 48”, 60” Stainless Steel construction - protects back wall and wipes clean easily • WCPI Remote control: With Stainless Steel faceplate, to fit any décor. INSERT SPECIFICATIONS 120 VAC, 60 Hz Amps (without blower) 0.8 (PIK33), 1.3 (PIK45)
HK0076A
18” 4 1/2''
14
4”
16”
HC0010
", 60"
2", 48
36", 4
BEST BY BROAN P.O. BOX 140 HARTFORD, WISCONSIN 53027 REFERENCE
QTY.
REMARKS
Project Location Architect Engineer Contractor Submitted by 40J
Date 99043298C
PIK MOUNTING
Suggested Custom Hood Internal Framework
SIZE OF THE CUT-OUT NOTE: If optional L series liner is used, refer to installation instructions for size and location of the cut-out. 3 1/2''
16 3/8''
17 1/16''
1 1/2”
32 1/2'' or 44 1/2'' 2 1/4'' min.
HD0093A
HH0040A
NOTE: The 3 1/2’’ notch must be cut only if the WCPI optional wall control will be installed.
PIK33
AND PIK45 INSERT SYSTEM
Model 647 (7” Rd wall cap)
Model 634 or 644 (roof cap)
Model 643 (8” Rd wall cap)
Model EB12 (1200 cfm) or EB15 (1500 cfm) exterior blower Model EB6 (600 cfm) or EB9 (900 cfm) exterior blower
8” Rd adjustable elbow (optional)
Model 415 7” Rd adjustable elbow (optional)
8” Rd standard duct
Model 407 (7” Rd x 24’’ section)
Model 418 10” Rd adjustable elbow (optional)
8” Rd metal flexible duct (optional)
7” Rd metal flexible duct (optional)
Model 459 transition (3 1/4” x 14” to 8”)
Model 412 transition (3 1/4” x 10” to 7”) Adapter and damper 3 1/4’’ x 10’’ (supplied with P5 and P8 blowers)
Model 413 transition (3 1/4” x 10” to 8”)
Adapter and damper 3 1/4’’ x 14’’ (supplied with P8 blower)
Model 421 (10” Rd. vert. in-line damper) Model 410 (10” Rd duct - 2ft. sections) 10” Rd metal flexible duct (optional)
Flow deviator (supplied with P5 and P8 blowers)
L3336, L3342, L4548 or L3336, L3342, L4548L3342S, or L4560 L4560, L3336S, Custom Hood Liner (optional) L4548S, L4560S Custom Hood Liner (optional)
PIK33 OR PIK45 INSERT
Exterior blower rough-in kit (included with EB6, EB9, EB12 and EB15 blowers
ALP36, ALP42, ALP30, ALP36, ALP48 ALP60 ALP42, ALP48 or or ALP60 Ambient light panel (optional) Ambient light panel (optional) Rough-in kit (supplied with P5 and P8 blowers)
WCPI Wall control (Optional)
Model P5 single-blower (500 cfm)
RMP Series Backsplash RMP Series Backsplash Stainless Steel wall covering (Stainless Steel wall with warming shelves. covering with warming Widths available: 36”, 42”, 48”, 60” shelves. Optional) (optional)
HL0041
Model P8 dual-blower (900 cfm) NOTE: The dual blower P8 can be installed either with 7’’ round or 8’’ round ductwork. For optimal air and quiet sound performance, use 8’’ round ductwork.
PIK SERIES INSERTS BLOWER DUCTING POSITIONS MODEL PIK33 WITH P8 BLOWER (Vertical Outlet)
HB0032
MODEL PIK45 WITH P8 BLOWER (Vertical Outlet)
Top view 3/4’’
16 1/8’’ 9 1/8’’
%.
Top view 7 5/8’’ 7/8’’
3 1/4’’
7/8’’ dia.
14’’
8’’ round transition
HK0031A
MODEL PIK33 WITH P5 BLOWER (Vertical Outlet)
3/4’’
22 1/8’’ 15 1/8’’
3/4’’
11 1/8’’
%.
7 5/8’’ 7/8’’
7/8’’ dia.
10’’
7’’ or 8’’ round transition
HK0030A
MODEL PIK33 WITH EB6, EB9, EB12 OR EB15 BLOWER (Vertical Outlet)
16 1/8’’
7/8’’
7/8’’ dia. 14’’ 8’’ round transition
HK0034A
MODEL PIK45 WITH P5 BLOWER (Vertical Outlet) Top view
3 1/4’’
Top view %.
13 5/8’’
3 1/4’’
Top view 16 1/8’’
%.
3/4’’
3 1/4’’
22 1/8’’ 17 1/8’’
%.
13 5/8’’ 7/8’’
7/8’’ dia. 10’’ 7’’ or 8’’ round transition
HK0033A
MODEL PIK45 WITH EB6, EB9, EB12 OR EB15 BLOWER (Vertical Outlet)
22 1/8’’
6 11/16’’ 1 11/16’’
Top view %. 12 11/16’’ 1 11/16’’
5 1/4’’
5 1/4’’ 7/8’’ dia.
7/8’’ dia. 9 5/8’’ dia.
9 5/8’’ dia. HK0032 HK0029