Appendix No. 4 Technical specifications Technical Specification 2DES a) 1x source of amplified femtosecond pulses with a regenerative amplifier: 1. Repetition rate adjustable between 100 Hz - 10 kHz, or better 2. Pulse energy stability better than 0.5% rms over 8 hours, beam pointing stability better than 25 µrad per one degree Celsius, and better than 25 µrad over 8 hours at a constant temperature. The method of stability determination should be described in the offer. 3. Output parameters (wavelength, pulse energy, pulse length) should meet the pump requirements for one or both NOPA amplifiers listed under b), and must ensure reaching the output parameters specified there. b) 2x non-collinear optical parametric amplifier, NOPA. Either one or both amplifiers will be pumped by the laser listed under a), depending on the type of the experiment. The combination of the pump laser a) and amplifiers should provide pulses with the following characteristics: 1. Pulses short 10-30 fs, at least in a part of the spectral range of the amplifier 2. Maximum pulse energy of at least 100 nJ 3. Spectral coverage of at least 75% of the spectral range between 300-1000 nm. It is required that the spectral range between 700-900 nm will be covered. Both amplifiers do not need to be same, and the required spectral coverage may be achieved by a combination of the parameters of both amplifiers, including their accessories generating a second harmonic frequency of the amplifier output. These accessories should be included in the offer. To ensure maximum compatibility, the devices listed under a) and b) should be from the same producer. c) 1x continuous wave diode-pumped solid-state laser 1. Wavelength 532 nm 2. Maximum power 10 W or more 3. Power stability better than 1% 4. Noise better than 0.05% 5. Mode TEM00 6. Beam quality (M-squared) better than 1.1 d) 1x research grade optical table with a vibration control 1. Size of the table depends on the dimensions of the lasers and requirements for their arrangement, but it should be at least 120 x 180 (240) x 305 (203, 477, 610) cm 2. Number of vibration isolators depends on the size of the table, but it should be at least four e) 1x electron multiplying CCD camera 1. CCD format 1600 x 200 or larger 2. Read noise better than 20 e rms 3. Operating temperature -60°C or lower without liquid cooling 4. Dark current 0.02 e/s/pixel or better at the operating temperature 5. Quantum efficiency et least 10% between 350-900 nm at room temperature 1 f) 1x imaging spectrometr 1. 200-350 mm focal length 2. Triple grating turret (600 gr/mm, 500 nm blaze; 600 gr/mm, 750 nm blaze) 3. PC controlled input shutter and slits To ensure maximum compatibility, the devices listed under e) and f) should be from the same producer. g) 1x pulse and delay generator 1. At least two pulse channels 2. At least four delay channels 3. Delay in a range of 0-100 s or larger, with at least 5 ps delay resolution 4. Jitter less than <100 ps rms 5. Adjustable amplitude and offset h) 1x fiber spectrometer 1. Spectral range at least 200-1100 nm 2. Signal to noise ratio at least 200:1 3. Including CCD array with at least 1024 pixels in a line i) 1x fiber spectrometer with a cooled detector 1. 75 mm symmetric Czerny-Turner setup 2. Spectral range at least 200-1100 nm 3. at least 3648 pixel 3-stage TE cooled and regulated CCD detector 4. signal to noise ratio at least 350:1, stray light below 1% 5. deep UV detector coating 6. excitation and collection optical fibers 7. compact deuterium-halogen lamp 8. including accessory (collection lenses, slit, order sorting filters) 9. software j) 1x oscilloscope 1. Four analog channels 2. Analog bandwidth 200 MHz or better 2. Signal detection with at least 10x over sampling on all channnels. 2. Sample rate 2GS/s or better 2