Preview only show first 10 pages with watermark. For full document please download

Pipe System With Economy Function Db-ta-33a

   EMBED


Share

Transcript

ROOM CONTROLLERS FOR FAN COIL WITH PROPORTIONAL INTEGRAL OUTPUT(S) FOR 2- AND 4- PIPE SYSTEM WITH ECONOMY FUNCTION DB-TA-33A FUNCTION Proportional integral temperature control in heating, ventilation, refrigeration and air conditioning for tipically 2- and 4- pipe fan coil systems with proportional valves. - 1 or 2 proportional outputs 0-10 Vdc - local or remote season change over (2- pipe system) - manual selection of On/Off, 3 fan speeds - economy function - autotuning function with remote sensor TYPE ON/OFF DB-TA-33A-10A • DB-TA-33A-13A • The thermostat is provided with a LCD display and keys +/- for parameter setting like the range, type of system, proportional band, integral time and economy mode. When the thermostat is on the fan is on at the speed selected manually and the proportional output are set according to parameters settings. In addition an economy function is available with a remote contact. When the contact is closed the thermostat works with an economy mode. 3- SPEED S/W see electrical wiring • see electrical wiring On request: optional remote 1 m cable sensor, selectable by jumper; ordering code: NTA010-623. TECHNICAL FEATURES Power supply: Input: Output(s): Power consump.: Sensor: Range: Economy: Prop. band: Integral time: Display: Working: Storage: Housing: Protection class: Size: Weight: 24 Vac ± 10%, 50/60 Hz - external contact for economy - external contact or water sensor for remote season change over function (2- pipe) 1 or 2 prop. outputs 0...10 Vdc (RL > 10 kOhm) speeds: 24...230 Vac 6 A 1W NTC 10K +5...+30 °C adjustable range between +5...+30 °C 1...30 K 1...30 minutes resolution 0.1 °C 0...+40 °C 10...90% r.h. (non condensing) -20...+60 °C < 95 % r.h. ABS self-extinguished according to UL94 V-0 color (RAL 9010) IP30, class II 144 x 82 x 34 mm 220 g 2- pipe: logic of season change over with water sensor Cooling Heating water C/O contact closed: reverse action (heating) C/O contact opened: direct action (cooling) In 2- pipe systems, season change over can be selected manually by parameter or can be done remotely by a water sensor or a centralized external contact. In 4- pipe systems, season change over is done automatically based on room temperature. ECO contact closed: economy function inserted ECO contact opened: economy function not inserted ELECTRICAL WIRING 4- pipe systems operating 2- pipe systems operating (**** ) only for DB-TA-33A-13A (**** ) only for DB-TA-33A-13A (*) optional remote sensor (**) optional water sensor (***) optional remote centralized contact 35 ROOM CONTROLLERS FOR 2- OR 4- PIPE FAN COILS DBTA-393 FUNCTION 2- pipe fan coil with 3- speed motor fan control for room temperature applications with: - manual selection of thermostatic fan/continuous fan/Off, - 3 motor speed and season change over; TYPE DBTA-393-433 - room temperature visualisation with display; setpoint selection by step of 0.5 °C on display; internal or remote temperature sensor (optional). VT/VC/OFF 3- SPEED LOCAL S/W • • • On request: optional remote 1 m cable sensor, selectable by jumper; ordering code: NTA010-623. TECHNICAL FEATURES Power supply: Max load: Output: Power cons.: Sensor: Range: Setpoint: Differential: Display: Working: Storage: Housing: Protection: Size: Weight: 230 Vac ± 10%, 50/60 Hz 6A 1 relay SPDT 230 Vac 6 A 1W NTC 10K 0...+40 °C +5...+30 °C adjustment by step of 0.5 °C. 0.5 °C resolution 0.1 °C 0...+40 °C 10...90% r.h. (non condensing) -20...+70 °C < 95 % r.h. ABS self-extinguished according to UL94 V-0 color (RAL 9010) IP30, class II 144 x 82 x 27 mm 220 g ELECTRICAL WIRING Terminal connections for 2-pipe air conditioning and heating systems. Terminal connections for 4- pipe air conditioning and heating systems. (*) TM optional remote sensor minimum thermostat Jumper setting: - J1 closed = internal sensor J1 opened = remote sensor The products are factory supplied with internal sensor. 36 ROOM CONTROLLERS FOR FAN COILS AND HEAT PUMPS DBTA-394 FUNCTION Control of 2- or 4- pipe fan coils, ventilation systems and heat pumps with reversing valve for room temperature applications with: - On/Off switch; - manual selection of 3 motor speed and operating in heating, TYPE DBTA-394-134 - only ventilation or cooling; setpoint adjustment with push buttons by step of 0.5 °C; start-up delay of compressor (2 minutes); internal or remote temperature sensor (optional). ON/OFF 3- SPEED W/FAN/S • • • On request: optional remote 1 m cable sensor, selectable by jumper; ordering code: NTA010-623. TECHNICAL FEATURES Power supply: Max load: Output: Power cons.: Sensor: Range: Setpoint: Differential: Display: Working: Storage: Housing: Protection: Size: Weight: 230 Vac ± 10%, 50/60 Hz 6A 1 SPDT relay 230 Vac 6 A 1W NTC 10K 0...+40 °C +5...+30 °C adjustment by step of 0.5 °C 0.5 K resolution 0.1 °C 0...+40 °C 10...90% r.h. (non condensing) -20...+70 °C < 95 % r.h. ABS self-extinguished according to UL94 V-0 color (RAL 9010) IP30, class II 144 x 82 x 34 mm 220 g Heating with electric heater systems Terminal connections for 4-pipe air conditioning, heating systems ELECTRICAL WIRING Terminal connections for 2- pipe heating, air conditioning 37 ROOM CONTROLLERS FOR FAN COILS AND HEAT PUMPS Terminal connections for heat pumps with reverse valve active in heating. DBTA-394 Terminal connections for heat pumps with reverse valve active in cooling. (*) optional remote sensor Jumper setting: - J1 closed = internal sensor J1 opened = remote sensor The products are factory supplied with internal sensor. 38 ROOM CONTROLLERS FOR 4- PIPE SYSTEM WITH 2 STAGES HEATING AND 2 STAGES COOLING DB-TA-3A3..0 FUNCTION 4- pipe fan coil control for room temperature applications with: - 2 heating relays outputs and 2 cooling relays outputs with dead zone (dEZ); - manual selection of 3 fan speeds and selection of type of ventilation with keys and parameter (model DB-TA-3A3-700 only) - internal or remote temperature sensor (optional). TYPE The thermostat is provided with a LCD display and keys +/- for parameters setting like the range, the neutral zone, hysteresis for heating and cooling stages, hysteresis between the heating stage 1 and 2 and between the cooling stage 1 and 2, the position of setpoint in the neutral zone, the type of ventilation (continuous, based on temperature, off) (model DB-TA-3A3-700 only). In normal condition of use the temperature is visualized with a step of 0.1°C. 3- SPEED HYS. BETWEEN STAGES K HYS. IN THE STAGES K • 0.5...4 0.5...4 0.5...4 0.5...4 DB-TA-3A3-700 DB-TA-3A3-000 On request: optional remote 1 m cable sensor, selectable by jumper; ordering code: NTA010-623. TECHNICAL FEATURES ELECTRICAL WIRING 230 Vac ± 10%, 50/60 Hz valves: 4 relay SPST 230 Vac 5 A speeds: 230 Vac 5 A, 50/60 Hz Power consumption: 1 W Sensor: NTC 10K Range: +5...+30 °C Hysteresis between the stages: 0.5...4 K Hysteresis in stages: 0.5...4 K Display: resolution 0.1 °C Working: 0...+40 °C 10...90% r.h. (non condensing) Storage: -20...+70 °C < 95 % r.h. Housing: ABS self-extinguished according to UL94 V-0 color (RAL 9010) Protection class: IP30, class II Size: 144 x 82 x 34 mm Weight: 220 g Power supply: Output: (*) only for models DB-TA-3A3-700 (**) remote sensor (optional) Logic of relay outputs Setpoint centered on neutral zone DiH DiC Hh1 Hh2 Hc1 Hc2 Setpoint on first heating stage differential between heating stages differential between cooling stages hysteresis heating stage 1 hysteresis heating stage 2 hysteresis cooling stage 1 hysteresis cooling stage 2 39 ROOM CONTROLLERS FOR 4- PIPE SYSTEM DB-TA-3A3..9 FUNCTION 4- pipe fan coil control for room temperature applications with: - 2 relays output with dead zone (dEZ); - manual selection of On/Off, 3 fan speeds (depending on model); - internal or remote temperature sensor (optional). The thermostat is provided with a LCD display and keys +/- for TYPE parameters setting like the range, the neutral zone, hysteresis for heating and cooling stages, the position of setpoint in the neutral zone. In normal condition of use the temperature is visualized with a step of 0.1 °C. The voltage free On/Off switch connected together with the 3 fan speeds switch allow to power on and off the fan. On request it is possible to have a version with economy function by a remote contact. When the contact is closed the thermostat works with an economy mode. ON/OFF 3- SPEED W/S DB-TA-3A3-139 • • zn DB-TA-3A3-199 • zn DB-TA-3A3-939 • zn DB-TA-3A3-999 zn zn dead zone On request: optional remote 1 m cable sensor, selectable by jumper; ordering code: NTA010-623. TECHNICAL FEATURES ELECTRICAL WIRING 230 Vac ± 10 %, 50/60 Hz valves: 2 relays SPDT 230 Vac 6 A speeds: 230 Vac 6 A, 50/60 Hz Power consumption: 1 W Sensor: NTC 10K Range: +5...+30 °C Hysteresis: 0.5...4 K Dead zone: 1...4 K Display: resolution 0.1 °C Working: 0...+40 °C 10...90% r.h. (non condensing) Storage: -20...+70 °C < 95 % r.h. Housing: ABS self-extinguished according to UL94 V-0 color (RAL 9010) Protection class: IP30, class II Size: 144 x 82 x 34 mm Weight: 220 g Power supply: Output: (*) only for models DB-TA-3A3-139, DB-TA-3A3-199 (**) only for models DB-TA-3A3-139, DB-TA-3A3-939 (***) remote sensor (optional) Logic of relays output Setpoint centered on neutral zone 40 Setpoint on heating stage ROOM CONTROLLERS FOR 4- PIPE SYSTEM DB-TA-3A3..A FUNCTION 4- pipe fan coil control for room temperature applications with: - 2 relays output with dead zone (dEZ); - manual selection of On/Off, 3 fan speeds (depending on model); - internal or remote temperature sensor (optional). - economy function parameters setting like the range, the neutral zone, hysteresis for heating and cooling stages, the position of setpoint in the neutral zone and economy mode state. In normal condition of use the temperature is visualized with a step of 0.1°C. The voltage free On/Off switch connected together with the 3 fan speeds switch allow to power on and off the fan. In addition activation by parameter of economy function is available directly on the unit or remotely by an external contact. The thermostat is provided with a LCD display and keys +/- for TYPE ON/OFF 3- SPEED W/S DB-TA-3A3-13A • • zn DB-TA-3A3-19A • zn DB-TA-3A3-93A • zn DB-TA-3A3-99A zn On request: optional remote 1 m cable sensor, selectable by jumper; ordering code: NTA010-623. TECHNICAL FEATURES Power supply: Input: Outputs: Power cons.: Sensor: Range: Hysteresis: Dead zone: Economy: Display: Working: Storage: Housing: Protection class: Size: Weight: ELECTRICAL WIRING 230 Vac ± 10 %, 50/60 Hz ext. contact for economy function 2 relays SPDT 230 Vac 6 A speeds: 230 Vac 6A, 50/60 Hz 1W NTC 10K +5...+30 °C 0.5...4 K 1...4 K adjustable range between +5...+30 °C resolution 0.1 °C 0...+40 °C 10...90% r.h. (non condensing) -20...+70 °C < 95 % r.h. ABS self-extinguished according to UL94 V-0 color (RAL 9010) IP30, class II 144 x 82 x 34 mm 220 g (*) (**) (***) (ECO) only for models DB-TA-3A3-13A, DB-TA-3A3-19A only for models DB-TA-3A3-13A, DB-TA-3A3-93A remote sensor (optional) economy function Logic of relay outputs Setpoint centered on neutral zone Setpoint on heating stage 41 ROOM CONTROLLERS FOR FAN COIL AND HEAT PUMPS WITH DISPLAY DB-TA-3A4-700 FUNCTION Control of 2-pipe fan coil, ventilation systems and heat pumps with reversible valve for room temperature applications with: - manual selection of 3 fan speeds and selection of type of ventilation with keys and parameter - setpoint adjustment with push/buttons by step of 0.1°C. - Additional electric heater with adjustable differential activation from the setpoint - adjustable hysteresis for compressor and electric heater. - start-up delay of compressor adjustable - internal or remote temperature sensor (optional). TYPE The thermostat is provided with a LCD display and keys +/- for parameters setting like the range, operating mode (heating, cooling, Off), the type of ventilation (continuous, based on temperature), differential between compressor and electric heater activation in heating mode, hysteresis for compressor and electric heater, delay for compressor activation. In normal condition of use the temperature is visualized with a step of 0.1°C. 3 SPEEDS LOCAL S/W • • DB-TA-3A4-700 On request: optional remote 1 m cable sensor, selectable by jumper; ordering code: NTA010-623. TECHNICAL FEATURES Power supply: Outputs: Power cons.: Sensor: Range: Hysteresis: Compressor delay: Display: Working: Storage: Housing: Protection class: Size: Weight: ELECTRICAL WIRING 230 Vac ± 10%, 50/60 Hz valves: 3 relays SPDT 230 Vac 5 A speeds: 230 Vac 6 A, 50/60 Hz 1W NTC 10K +5...+30 °C 0.5...4 K 0...10 minutes resolution 0.1 °C 0...+40 °C 10...90% r.h. (non condensing) -20...+70 °C < 95 % r.h. ABS self-extinguished according to UL94 V-0 color (RAL 9010) IP30, class II 144 x 82 x 34 mm 220 g (*) remote sensor (optional) Logic of relay outputs Heating mode reversing valve OFF diH HrE Hco COMP RES. Cooling mode reversing valve ON Δt between activation of RES and COMP hysteresis of RES hysteresis of COMP compressor electric heater The fan is activated and deactivated together with the compressor if the mode of ventilation is based on temperature, otherwise the fan is always on. 42 ROOM THERMOSTATS FOR FAN COIL WITH 2 PROPORTIONAL OUTPUTS FOR 4- PIPE SYSTEM DB-TA-3A5 FUNCTION Temperature control in heating, ventilation, refrigeration and air conditioning for tipically 4- pipe fan coil systems with proportional valves. - 2 proportional outputs 0…10 Vdc - manual selection of On/Off, 3 fan speeds The thermostat is provided with a LCD display and keys +/- for TYPE DB-TA-3A5-130 parameters setting like the range, the neutral zone, proportional heating and cooling bands. In normal condition of use the temperature is visualized with a step of 0.1°C. When the thermostat is off, the fan is off, the proportional outputs are set to 0 Vdc. When the thermostat is on the fan is on at the speed selected manually and the proportional outputs are set according to parameters setting. ON/OFF 3- SPEED DEAD ZONE K • • 1...4 • 1...4 DB-TA-3A5-030 • DB-TA-3A5-100 1...4 1...4 DB-TA-3A5-000 TECHNICAL FEATURES Power supply: Outputs: Power cons.: Sensor: Range: Prop. band: Display: Working: Storage: Housing: Protection class: Size: Weight: ELECTRICAL WIRING 24 Vac ± 10%, 50/60 Hz valves: 2 prop. outputs 0...10 Vdc (RL>10 kOhm) speeds: 24...230 Vac 6 A, 50/60 Hz 1W NTC 10K +5...+30 °C ± 0.5...± 2.5 K resolution 0.1 °C 0...+40 °C 10...90% r.h. (non condensing) -20...+70 °C < 95 % r.h. ABS self-extinguished according to UL94 V-0 color (RAL 9010) IP30, class II 144 x 82 x 34 mm 220 g (*) only for models DB-TA-3A5-130, DB-TA-3A5-100 (**) only for models DB-TA-3A5-130, DB-TA-3A5-030 Logic of proportional output Tset centered in BP heating ZN PBH PBC Tset centered in dead zone neutral zone proportional heating band proportional cooling band 43 ROOM THERMOSTATS FOR FAN COIL WITH 2 PROPORTIONAL OUTPUTS FOR 4- PIPE SYSTEM WITH ECONOMY FUNCTION DB-TA-3A5..A FUNCTION Temperature control in heating, ventilation, refrigeration and air conditioning for typically 4- pipe fan-coil systems with proportional valves. - 2 proportional outputs 0…10 Vdc with dead zone - manual selection of On/Off, 3 fan speeds - economy function parameters setting like the range, the neutral zone, proportional heating and cooling bands, economy mode. When the thermostat is on the fan is on at the speed selected manually and the proportional outputs are set according to parameters setting. In addition an economy function is available with a remote contact. When the contact is closed the thermostat works with an economy mode. The thermostat is provided with a LCD display and keys +/- for TYPE DB-TA-3A5-13A ON/OFF 3- SPEED DEAD ZONE K • • 1...4 • 1...4 DB-TA-3A5-03A DB-TA-3A5-10A • 1...4 1...4 DB-TA-3A5-00A ELECTRICAL WIRING TECHNICAL FEATURES 24 Vac ± 10%, 50-60 Hz external contact for economy function valves:2 prop. outputs 0...10 Vdc (RL > 10 kOhm) speeds: 24...230 Vac 6 A, 50/60 Hz Power cons.: 1W Sensor: NTC 10K Range: +5...+30 °C Prop. band: ± 0,5...± 2,5 K Economy: adjustable range between +5...+30 °C Display: resolution 0.1°C Working: 0...+40 °C 10...90% r.h. (non condensing) Storage: -20...+70 °C < 95 % r.h. Housing: ABS self-extinguished according to UL94 V-0 color (RAL 9010) Protection class.: IP30, class II Size: 144 x 82 x 34 mm Weight: 220 g Power supply: Input: Outputs: ECONOMY FUNCTION contact closed: economy function selected ECONOMY FUNCTION contact opened: economy function not selected (*) only for models DB-TA-3A5-13A, DB-TA-3A5-10A (**) only for models DB-TA-3A5-13A, DB-TA-3A5-03A Logic of proportional output Tset centered in neutral zone Tset centered in BP heating ZN PBH PBC 44 neutral zone proportional heating band proportional cooling band ROOM THERMOSTATS FOR FAN COIL WITH PROPORTIONAL OUTPUT FOR 2- PIPE SYSTEM DB-TA-3B5 FUNCTION Temperature control in heating, ventilation, refrigeration and air conditioning for tipically 2- pipe fan coil systems with proportional valve. - 1 proportional output 0…10 Vdc - manual selection of On/Off, 3 fan speeds reverse) and proportional band. In normal condition of use the temperature is visualized with a step of 0.1°C. When the thermostat is off, the fan is off, the proportional output is set to 0 Vdc. When the thermostat is on the fan is on at the speed selected manually by the switch and the proportional output is set according to parameters setting. The thermostat is provided with a LCD display and keys +/- for parameters setting like the range, the type of action (direct or TYPE DB-TA-3B5-130 ON/OFF 3- SPEED S/W • • local • local DB-TA-3B5-030 • DB-TA-3B5-100 local local DB-TA-3B5-000 ELECTRICAL WIRING TECHNICAL FEATURES 24 Vac ± 10%, 50/60 Hz valves: 1 prop. output 0...10 Vdc (RL > 10 kOhm) speeds: 24/230 Vac 6 A, 50/60 Hz Power cons.: 1W Sensor: NTC 10K Range: +5...+30 °C Prop. band: ± 0,5...± 2,5 K Display: resolution 0.1 °C Working: 0...+40 °C 10...90% r.h. (non condensing) Storage: -20...+70 °C < 95 % r.h. Housing: ABS self-extinguished according to UL94 V-0 color (RAL 9010) Protection class: IP30, class II Size: 144 x 82 x 34 mm Weight: 220 g Power supply: Outputs: (*) only for models DB-TA-3B5-130, DB-TA-3B5-100 (**) only for models DB-TA-3B5-130, DB-TA-3B5-030 Logic of proportional output Reverse action PB Direct action proportional band 45 ROOM THERMOSTATS FOR FAN COIL WITH PROPORTIONAL OUTPUT FOR 2- PIPE SYSTEM WITH ECONOMY FUNCTION AND REMOTE SEASON CHANGE OVER DB-TA-3B5..A FUNCTION Temperature control in heating, ventilation, refrigeration and air conditioning for tipically 2- pipe fan coil systems with proportional valve. - 1 proportional output 0…10 Vdc - 1 remote season change over - manual selection of On/Off, 3 fan speed - economy function TYPE DB-TA-3B5-13A The thermostat is provided with a LCD display and keys +/for parameters setting like the range, proportional band and economy mode. When the thermostat is on the fan is on at the speed selected manually and the proportional output is set according to parameter setting. In addition an economy function is available with a remote contact. When the contact is closed the thermostat works with an economy mode. ON/OFF 3- SPEED S/W • • remote • remote DB-TA-3B5-03A • DB-TA-3B5-10A remote remote DB-TA-3B5-00A ELECTRICAL WIRING TECHNICAL FEATURES Power supply: Inputs: Outputs: Power consump.: Sensor: Range: Economy: Prop. band: Display: Working: Storage: Housing: Protection class: Size: Weight: 24 Vac ± 10%, 50/60 Hz external contacts for economy and season change over function 1 prop. output 0...10 Vdc (RL > 10 kOhm) speeds: 24...230 Vac 6 A, 50/60 Hz 1W NTC 10K +5...+30 °C adjustable range between +5...+30 °C ± 0,5...± 2,5 K resolution 0.1 °C 0...+40 °C 10...90% r.h. (non condensing) -20...+70 °C < 95 % r.h. ABS self-extinguished according to UL94 V-0 color (RAL 9010) IP30, class II 144 x 82 x 34 mm 220 g DB-TA-3B5-XXA ECONOMY FUNCTION contact closed: economy function selected ECONOMY FUNCTION contact opened: economy function not selected SEASON CHANGE OVER contact closed: reverse action (heating) SEASON CHANGE OVER contact opened: direct action (cooling) (*) only for models DB-TA-3B5-13A, DB-TA-3B5-10A (**) only for models DB-TA-3B5-13A, DB-TA-3B5-03A Logic of proportional output Reverse action Direct action PB 46 proportional band ROOM THERMOSTATS FOR FAN COIL WITH 2 PROPORTIONAL OUTPUTS FOR 4- PIPE SYSTEM AND HEATING RELAY OUTPUT DB-TA-3A8 FUNCTION Temperature control in heating, ventilation, refrigeration and air conditioning for tipically 4- pipe fan coil systems with proportional valves. - 1 heating relay output - 2 proportional outputs 0…10 Vdc with dead zone - manual selection of On/Off, 3 fan speeds The thermostat is provided with a LCD display and keys +/- for parameter setting like the range, the neutral zone, proportional TYPE DB-TA-3A8-130 heating and cooling bands. In normal condition of use the temperature is visualized with a step of 0.1°C. When the thermostat is off, the fan is off, the proportional outputs are set to 0 Vdc and the relay is off. When the thermostat is on the fan is on at the speed selected manually and the proportional outputs are set according to parameter ssetting. The relay is activated if heating function is required when the maximum heating voltage output has been reached but not the temperature required. ON/OFF 3- SPEED DEAD ZONE K • • 1...4 • DB-TA-3A8-030 DB-TA-3A8-100 1...4 • 1...4 1...4 DB-TA-3A8-000 ELECTRICAL WIRING TECHNICAL FEATURES 24 Vac ± 10%, 50/60 Hz valves: 2 prop. outputs 0...10 Vdc (RL > 10 kOhm) 1 relay output 6 A 250 Vac speeds: 24/230 Vac 6 A, 50/60 Hz Power cons.: 1W Sensor: NTC 10K Range: +5...+30 °C Differential: 0.4 K (relay) Prop. band: ± 0,5...± 2,5 K Display: resolution 0.1 °C Working: 0...+40 °C 10...90% r.h. (non condensing) Storage: -20...+70 °C < 95 % r.h. Housing: ABS self-extinguished according to UL94 V-0 color (RAL 9010) Protection class: IP30, class II Size: 144 x 82 x 34 mm Weight: 220 g Power supply: Outputs: (*) (**) only for models DB-TA-3A8-130, DB-TA-3A8-100 only for models DB-TA-3A8-130, DB-TA-3A8-030 Logic of proportional outputs Tset centered in BP heating Tset centered in dead zone Logic of operating relay ZN PBH PBC neutral zone proportional heating band proportional cooling band 47 ROOM THERMOSTATS FOR FAN COIL WITH 2 PROPORTIONAL OUTPUTS FOR 4- PIPE SYSTEM AND HEATING RELAY OUTPUT WITH ECONOMY FUNCTION DB-TA-3A8..A FUNCTION Temperature control in heating, ventilation, refrigeration and air conditioning for tipically 4- pipe fan coil systems with proportional valves. - 1 heating relay output - 2 proportional outputs 0…10 Vdc with dead zone - manual selection of On/Off, 3 fan speeds - economy function The thermostat is provided with a LCD display and keys +/- for parameters setting like the range, the neutral zone, proportioTYPE DB-TA-3A8-13A ON/OFF 3- SPEED DEAD ZONE K • • 1...4 • 1...4 DB-TA-3A8-03A DB-TA-3A8-10A nal heating and cooling bands and economy mode. When the thermostat is on the fan is on at the speed selected manually and the proportional outputs are set according to parameters setting. The relay is activated if heating function is required when the maximum heating voltage output has been reached but not the temperature required. In addition an economy function is available with a remote contact. When the contact is closed the thermostat works with an economy mode. • 1...4 DB-TA-3A8-00A 1...4 ELECTRICAL WIRING TECHNICAL FEATURES Power supply: Input: Outputs: Power cons.: Sensor: Range: Differential: Prop. band: Economy: Display: Working: Storage: Housing: Protection class: Size: Weight: 24 Vac ± 10%, 50/60 Hz external contact for economy function valves: 2 prop. outputs 0...10 Vdc (RL > 10 kOhm) 1 relay 6 A 250 Vac speeds: 6 A at 24...230 Vac ±10%, 50/60 Hz 1W NTC 10K +5...+30 °C 0.4 K (relay) ± 0,5...± 2,5 K adjustable range between +5...+30 °C resolution 0.1 °C 0...+40 °C 10...90% r.h. (non condensing) -20...+70 °C < 95 % r.h. ABS self-extinguished according to UL94 V-0 color (RAL 9010) IP30, class II 144 x 82 x 34 mm 220 g ECONOMY FUNCTION contact closed: economy function selected ECONOMY FUNCTION contact opened: economy function not selected (*) only for models DB-TA-3A8-13A, DB-TA-3A8-10A (**) only for models DB-TA-3A8-13A, DB-TA-3A8-03A Tset centered in BP heating Logic of proportional outputs Logic of operating relay Tset centered in dead zone ZN PBH PBC 48 neutral zone proportional heating band proportional cooling band ROOM CONTROLLERS FOR FAN COIL WITH 1 PROPORTIONAL OUTPUT AND 1 RELAY OUTPUT FOR 4- PIPE SYSTEM DB-TA-3A9 FUNCTION Temperature control in heating, ventilation, refrigeration and air conditioning for tipically 4- pipe fan coil systems. - 1 heating relay output - 1 proportional output 0…10 Vdc - manual selection of On/Off, 3 fan speed The thermostat is provided with a LCD display and keys +/- for parameters setting like the range, the neutral zone, proportional TYPE DB-TA-3A9-130 ON/OFF 3- SPEED DEAD ZONE K • • 1...4 • 1...4 DB-TA-3A9-030 DB-TA-3A9-100 band. In normal condition of use the temperature is visualized with a step of 0.1°C. When the thermostat is off, the fan is off, the proportional output is set to 0 Vdc and the relay is off. When the thermostat is on the fan is on at the speed selected manually and the proportional output is set according to parameter setting. The relay is activated with action opposed to the action of the proportional output. • 1...4 1...4 DB-TA-3A9-000 TECHNICAL FEATURES 24 Vac ± 10%, 50/60 Hz valves: 1 prop. output 0…10 Vdc (RL > 10 kOhm) 1 relay output 6 A 250 Vac speeds: 24/230 Vac 6 A Power cons.: 1W Sensor: NTC 10K Range: +5...+30 °C Differential: 0.5...2 K (relay) Prop. band: ± 0.5...± 2.5 K Display: resolution 0.1 °C Working: 0...+40 °C 10...90% r.h. (non condensing) Storage: -20...+70 °C < 95 % r.h. Housing: ABS self-extinguished according to UL94 V-0 color (RAL 9010) Protection class: IP30, class II Size: 144 x 82 x 34 mm Weight: 220 g ELECTRICAL WIRING Power supply: Outputs: (*) only for models DB-TA-3A9-130, DB-TA-3A9-100 (**) only for models DB-TA-3A9-130, DB-TA-3A9-030 49 ROOM CONTROLLERS FOR FAN COIL WITH 1 PROPORTIONAL OUTPUT AND 1 RELAY OUTPUT FOR 4- PIPE SYSTEM Logic of outputs Tset centered in heating Tset centered in dead zone proportional cooling on/off heating proportional heating on/off cooling ZN PB HYS 50 neutral zone proportional band hysteresis DB-TA-3A9 ROOM THERMOSTATS FOR FAN COIL WITH 1 PROPORTIONAL OUTPUT AND 1 RELAY OUTPUT FOR 4- PIPE SYSTEM WITH ECONOMY FUNCTION DB-TA-3A9..A FUNCTION Temperature control in heating, ventilation, refrigeration and air conditioning for tipically 4- pipe fan coil systems. - 1 heating relay - 1 proportional output 0…10 Vdc - manual selection of On/Off, 3 fan speed - economy function The thermostat is provided with a LCD display and keys +/- for parameters setting like the range, the neutral zone, TIPO DB-TA-3A9-13A proportional band and economy mode. When the thermostat is on the fan is on at the speed selected manually and the proportional output is set according to parameters setting. The relay is activated with action opposed to the action of the proportional output. In addition an economy function is available with a remote contact. When the contact is closed the thermostat works in economy mode. ON/OFF 3- SPEED DEAD ZONE K • • 1...4 DB-TA-3A9-03A • DB-TA-3A9-10A • DB-TA-3A9-00A 1...4 TECHNICAL FEATURES Power supply: Input: Outputs: Power cons.: Sensor: Range: Differential: Prop. band: Economy: Display: Working: Storage: Housing: Protection class: Size: Weight: 1...4 1...4 ELECTRICAL WIRING 24 Vac ± 10%, 50-60 Hz external contact for economy function valves: 1 prop. output 0…10 Vdc (RL > 10 kOhm) 1 relay 6 A 250 Vac speeds: 24/230 Vac 6 A, 50/60 Hz 1W NTC 10K +5...+30 °C 0.5...2 K (relay) ± 0.5...± 2.5 K adjustable range between +5...+30 °C resolution 0.1 °C 0...+40 °C 10...90% r.h. (non condensing) -20...+70 °C < 95 % r.h. ABS self-extinguished according to UL94 V-0 color (RAL 9010) IP30, class II 144 x 82 x 34 mm 220 g ECONOMY FUNCTION contact closed: economy function selected ECONOMY FUNCTION contact closed: economy function selected (*) (**) only for models DB-TA-3A9-13A, DB-TA-3A9-10A only for models DB-TA-3A9-13A, DB-TA-3A9-03A 51 ROOM THERMOSTATS FOR FAN COIL WITH 1 PROPORTIONAL OUTPUT AND 1 RELAY OUTPUT FOR 4- PIPE SYSTEM WITH ECONOMY FUNCTION DB-TA-3A9..A Logic of outputs Tset centered in heating Tset centered in dead zone proportional cooling on/off heating proportional heating on/off cooling ZN PB HYS 52 neutral zone proportional band hysteresis ROOM THERMOSTATS FOR FAN COIL WITH PROPORTIONAL OUTPUT FOR 2- PIPE SYSTEM AND RELAY OUTPUT DB-TA-3B8 FUNCTION Temperature control in heating, ventilation, refrigeration and air conditioning for tipically 2-pipe fan coil systems with proportional valve. - 1 relay output - 1 proportional output 0…10 Vdc - manual selection of On/Off, 3 fan speed reverse), proportional band. When the thermostat is on the fan is on at the speed selected manually and the proportional output is set according to parameters setting. Reverse action: the relay is activated when the maximum voltage output has been reached but not the required temperature. Direct action: the relay is activated when the maximum voltage output has been reached but not the required temperature. The thermostat is provided with a LCD display and keys +/- for parameters setting like the range, the type of action (direct or TYPE DB-TA-3B8-130 ON/OFF 3- SPEED S/W • • local • local DB-TA-3B8-030 • DB-TA-3B8-100 local local DB-TA-3B8-000 ELECTRICAL WIRING TECHNICAL FEATURES 24 Vac ± 10%, 50/60 Hz valves: 1 prop. output 0…10 Vdc (RL > 10 kOhm) 1 relay 6 A 250 Vac speeds: 6 A 24/230 Vac 6 A, 50/60 Hz Power cons.: 1W Sensore: NTC 10K Range: +5...+30 °C Differential: 0.4 °C (relay) Prop. band: ± 0,5...± 2,5 K Display: resolution 0.1 °C Working: 0...+40 °C 10...90% r.h. (non condensing) Storage: -20...+70 °C < 95 % r.h. Housing: ABS self-extinguished according to UL94 V-0 color (RAL 9010) Protection class: IP30, class II Size: 144 x 82 x 34 mm Weight: 220 g Power supply: Outputs: (*) (**) only for models DB-TA-3B8-130, DB-TA-3B8-100 only for models DB-TA-3B8-130, DB-TA-3B8-030 Logic of proportional output and operating relay Reverse action PB Direct action proportional band 53 ROOM THERMOSTATS FOR FAN COIL WITH PROPORTIONAL OUTPUT FOR 2- PIPE SYSTEM AND RELAY OUTPUT WITH ECONOMY FUNCTION AND REMOTE SEASON CHANGE OVER DB-TA-3B8..A FUNCTION Temperature control in heating, ventilation, refrigeration and air conditioning for tipically 2- pipe fan coil systems with proportional valve. - 1 relay output - 1 proportional output 0…10 Vdc - manual selection of On/Off, 3 fan speed - 1 remote season change over - economy function The thermostat is provided with a LCD display and keys +/for parameters setting like the range, proportional band and TYPE DB-TA-3B8-13A economy mode. The selection of type of action is done with a remote centralized contact. When the thermostat is on the fan is on at the speed selected manually and the proportional output is set according to parameters setting. Reverse action: the relay is activated when the maximum voltage output has been reached but not the required temperature. Direct action: the relay is activated when the maximum voltage output has been reached but not the required temperature. In addition an economy function is available with a remote contact. When the contact is closed the thermostat works in economy mode. ON/OFF 3- SPEED S/W • • remote • remote DB-TA-3B8-03A • DB-TA-3B8-10A remote remote DB-TA-3B8-00A TECHNICAL FEATURES ELECTRICAL WIRING 24 Vac ± 10%, 50/60 Hz external contacts for economy and season change over function Output: valves: 1 prop. output 0…10 Vdc (RL > 10 kOhm) 1 relay 6 A 250 Vac speed: 6 A 24/230 Vac ±10%, 50/60 Hz Power cons.: 1W Sensor: NTC 10K Range: +5...+30 °C Differential: 0.4 °C (relay) Prop. band: ± 0.5...± 2.5 K Economy: adjustable range between +5...+30 °C Display: resolution 0.1 °C Working: 0...+40 °C 10...90% r.h. (non condensing) Storage: -20...+70 °C < 95 % r.h. Housing: ABS self-extinguished according to UL94 V-0 color (RAL 9010) Protection class: IP30, class II Size: 144 x 82 x 35 mm Weight: 220 g Power supply: Ingresso: ECONOMY FUNCTION contact closed: economy function inserted ECONOMY FUNCTION contact opened: economy function not inserted SEASON CHANGE OVER contact closed: reverse action (heating) SEASON CHANGE OVER contact opened: direct action (cooling) (*) (**) only for models DB-TA-3B8-13A, DB-TA-3B8-10A only for models DB-TA-3B8-13A, DB-TA-3B8-03A Logic of proportional output and operating relay Reverse action Direct action PB proportional band Note: the relay can be set to work only in one season 54 2 STAGES ROOM THERMOSTATS FOR FAN COIL DB-TA-3C3..9 FUNCTION Temperature control in heating, refrigeration and air conditioning for tipically fan coil systems with 2 stages. - 2 relay outputs; - manual selection of On/Off, 3 fan speeds (depending on model); - internal or remote temperature sensor (optional). reverse), the differential between the stages and the differential in the stages. In normal condition of use the temperature is visualized with a step of 0.1°C. The voltage free On/Off switch connected together the 3 fan speeds switch allows to power on and off the fan. On request it is possible to have a version with economy function by a remote contact. When the contact is closed the thermostat works in economy mode. The thermostat is provided with a LCD display and keys +/- for parameters setting like the range, the type of action (direct or TYPE ON/OFF 3- SPEED DIFFERENTIAL/HYSTERESIS K DB-TA-3C3-139 • • 0.5...4 DB-TA-3C3-199 • 0.5...4 • DB-TA-3C3-939 0.5...4 0.5...4 DB-TA-3C3-999 On request: optional remote 1 m cable sensor, selectable by jumper; ordering code: NTA010-623. TECHNICAL FEATURES Power supply: Outputs: Power cons.: Sensor: Range: Hysteresis between stages: Hysteresis in stages: Display: Working: Storage: Housing: Protection class: Size: Weight: ELECTRICAL WIRING 230 Vac ± 10 %, 50/60 Hz valves: 2 relays SPDT 230 Vac 6 A speeds: 230 Vac 6 A, 50/60 Hz 1W NTC 10K +5...+30 °C 0.5...4 K 0.5...4 K resolution 0.1 °C 0...+40 °C 10...90% r.h. (non condensing) -20...+70 °C < 95 % r.h. ABS self-extinguished according to UL94 V-0 color (RAL 9010) IP30, class II 144 x 82 x 34 mm 220 g (*) only for models DB-TA-3C3-139, DB-TA-3C3-199 (**) only for models DB-TA-3C3-139, DB-TA-3C3-939 (***) remote sensor (optional) Logic of relay outputs Reverse action DiF Hi1 Hi2 Direct action temperature difference between activation of stage 1 and 2 hysteresis stage 1 hysteresis stage 2 55 DB-TA-3C3..A 2 STAGES ROOM THERMOSTATS FOR FAN COIL FUNCTION Temperature control in heating, refrigeration and air conditioning for tipically fan coil systems with 2 stages. - 2 relay outputs; - manual selection of On/Off, 3 fan speeds (depending on model); - internal or remote temperature sensor (optional); - economy function. The thermostat is provided with a LCD display and keys +/- for parameter setting like the range, the type of action (direct or TYPE reverse), the differential between the stages, the differential in the stages and economy mode state. In normal condition of use the temperature is visualized with a step of 0.1°C. The voltage free On/Off switch connected together with the 3 fan speeds switch allows to power on and off the fan. In addition activation by parameter of economy function is available directly on the unit or remotely by an external contact. ON/OFF 3- SPEED DB-TA-3C3-13A • • DB-TA-3C3-19A • DIFFERENTIAL/HYSTERESIS K 0.5...4 0.5...4 DB-TA-3C3-93A • 0.5...4 DB-TA-3C3-99A 0.5...4 On request: optional remote 1 m cable sensor, selectable by jumper; ordering code: NTA010-623. TECHNICAL FEATURES ELECTRICAL WIRING 230 Vac ± 10 %, 50/60 Hz ext. contact for economy function valves: 2 relays SPDT 230 Vac 6 A speeds: 230 Vac 6 A, 50/60 Hz Power consumption: 1 W Sensor: NTC 10K Range: +5...+30 °C Hysteresis between the stages: 0.5...4 K Hysteresis in stages: 0.5...4 K Economy: adjustable range between +5...+30 °C Display: resolution 0.1 °C Working: 0...+40 °C 10...90% r.h. (non condensing) Storage: -20...+70 °C < 95 % r.h. Housing: ABS self-extinguished according to UL94 V-0 color (RAL 9010) Protection class: IP30, class II Size: 144 x 82 x 34 mm Weight: 220 g Power supply: Input: Outputs: (*) only for models DB-TA-3C3-13A, DB-TA-3C3-19A (**) only for models DB-TA-3C3-13A, DB-TA-3C3-93A (***) remote sensor (optional) Logic of relay outputs Reverse action DiF Hi1 Hi2 56 Direct action temperature difference between activation of stage 1 and 2 hysteresis stage 1 hysteresis stage 2 ONE STAGE ROOM THERMOSTATS FOR FAN COIL DB-TA-3E3..9 FUNCTION Temperature control for tipically 2- pipe fan coil systems with one stage. - 1 cooling relay output; - manual selection of On/Off, 3 fan speed (depending on model); - internal or remote temperature sensor (optional). TYPE The thermostat is provided with a LCD display and keys +/- for parameters setting like the range, the differential in the stage, the mode of oprerating. In normal condition of use the temperature is visualized with a step of 0.1°C. The voltage free On/Off switch connected together with the 3 fan speeds switch allows to power on and off the fan. ON/OFF 3- SPEED HYSTERESIS K DB-TA-3E3-139 • • 0.5...4 DB-TA-3E3-199 • 0.5...4 DB-TA-3E3-939 • DB-TA-3E3-999 0.5...4 0.5...4 On request: optional remote 1 m cable sensor, selectable by jumper; ordering code: NTA010-623. TECHNICAL FEATURES Power supply: Outputs: Power cons.: Sensor: Range: Hysteresis in stage: Display: Working: Storage: Housing: Protection class: Size: Weight: ELECTRICAL WIRING 230 Vac ± 10 %, 50/60 Hz 1 relay SPDT 230 Vac 6 A speed: 230 Vac 6 A, 50/60 Hz 1W NTC 10K +5...+30 °C 0.5...4 K resolution 0.1 °C 0...+40 °C 10...90% r.h. (non condensing) -20...+70 °C < 95 % r.h. ABS self-extinguished according to UL94 V-0 color (RAL 9010) IP30, class II 144 x 82 x 27 mm 220 g (*) only for models DB-TA-3E3-139, DB-TA-3E3-199 (**) only for models DB-TA-3E3-139, DB-TA-3E3-939 (***) remote sensor (optional) Logic of relay outputs Direct action Hi1 hysteresis 57 ONE STAGE ROOM THERMOSTATS FOR FAN COIL DB-TA-3E3..A FUNCTION Temperature control for tipically 2- pipe fan coil systems with one stage. - 1 cooling relay output; - manual selection of On/Off, 3 fan speed (depending on model); - internal or remote temperature sensor (optional). +/- for parameters setting like the range, the differential in the stage, the mode of oprerating. In normal condition of use the temperature is visualized with a step of 0.1°C. The voltage free On/Off switch connected together with the 3 fan speeds switch allows to power on and off the fan. On request it is possible to have a version with economy function by a remote contact. When the contact is closed the thermostat works with an economy mode. The thermostat is provided with a LCD display and keys TYPE ON/OFF 3- SPEED HYSTERESIS K DB-TA-3E3-13A • • 0.5...4 DB-TA-3E3-19A • 0.5...4 DB-TA-3E3-93A • DB-TA-3E3-99A 0.5...4 0.5...4 On request: optional remote 1 m cable sensor, selectable by jumper; ordering code: NTA010-623. TECHNICAL FEATURES Power supply: IInput: Outputs: Power cons.: Sensor: Range: Hysteresis in stage: Display: Working: Storage: Housing: Protection class: Size: Weight: ELECTRICAL WIRING 230 Vca ± 10 %, 50/60 Hz ext. contact for economy function 1 relay SPDT 230 Vac 6 A speed: 230 Vac 6 A, 50/60 Hz 1W NTC 10K +5...+30 ºC 0.5...4 K resolution 0.1 ºC 0...+40 ºC 10...90% r.h. (non condensing) -20...+70 ºC < 95% r.h. ABS self-extinguished according to UL94 V-0 color (RAL 9010) (*) only for models DB-TA-3E3-13A, DB-TA-3E3-199A IP30, class II (**) only for models DB-TA-3E3-13A, DB-TA-3E3-93A 144 x 82 x 27 mm (***) remote sensor (optional) 220 g Logic of relay outputs Direct action Hi1 58 hysteresis ONE STAGE ROOM THERMOSTATS FOR FAN COIL DB-TA-3F3..9 FUNCTION The thermostat is provided with a LCD display and keys +/- for parameters setting like the range, the differential in the stage, the mode of oprerating. In normal condition of use the temperature is visualized with a step of 0.1°C. The voltage free On/Off switch connected together with the 3 fan speeds switch allows to power on and off the fan. Temperature control for tipically 2- pipe fan coil systems with one stage. - 1 relay output; - manual selection of On/Off, 3 fan speed (depending on model); - internal or remote temperature sensor (optional). TYPE ON/OFF 3- SPEED HYSTERESIS K DB-TA-3F3-139 • • 0.5...4 DB-TA-3F3-199 • 0.5...4 DB-TA-3F3-939 • 0.5...4 DB-TA-3F3-999 0.5...4 On request: optional remote 1 m cable sensor, selectable by jumper; ordering code: NTA010-623. TECHNICAL FEATURES Power supply: Outputs: Power cons.: Sensor: Range: Hysteresis in stage: Display: Working: Storage: Housing: Protection class: Size: Weight: ELECTRICAL WIRING 230 Vac ± 10 %, 50/60 Hz 1 relay SPDT 230 Vac 6 A speed: 230 Vac 6 A, 50/60 Hz 1W NTC 10K +5...+30 °C 0.5...4 K resolution 0.1 °C 0...+40 °C 10...90% r.h. (non condensing) -20...+70 °C < 95 % r.h. ABS self-extinguished according to UL94 V-0 color (RAL 9010) IP30, class II 144 x 82 x 27 mm 220 g (*) only for models DB-TA-3F3-139, DB-TA-3F3-199 (**) only for models DB-TA-3F3-139, DB-TA-3F3-939 (***) remote sensor (optional) Logic of relay outputs Direct action Reverse action Hi1 hysteresis 59 ONE STAGE ROOM THERMOSTATS FOR FAN COIL DB-TA-3F3..A FUNCTION +/- for parameters setting like the range, the differential in the stage, the mode of oprerating. In normal condition of use the temperature is visualized with a step of 0.1°C. The voltage free On/Off switch connected together with the 3 fan speeds switch allows to power on and off the fan. On request it is possible to have a version with economy function by a remote contact. When the contact is closed the thermostat works with an economy mode. Temperature control for tipically 2- pipe fan coil systems with one stage. - 1 relay output; - manual selection of On/Off, 3 fan speed (depending on model); - internal or remote temperature sensor (optional). The thermostat is provided with a LCD display and keys TYPE ON/OFF 3- SPEED HYSTERESIS K DB-TA-3F3-13A • • 0.5...4 DB-TA-3F3-19A • 0.5...4 DB-TA-3F3-93A • DB-TA-3F3-99A 0.5...4 0.5...4 On request: optional remote 1 m cable sensor, selectable by jumper; ordering code: NTA010-623. ELECTRICAL WIRING TECHNICAL FEATURES Power supply: IInput: Outputs: Power cons.: Sensor: Range: Hysteresis in stage: Display: Working: Storage: Housing: Protection class: Size: Weight: 230 Vca ± 10 %, 50/60 Hz ext. contact for economy function 1 relay SPDT 230 Vac 6 A speed: 230 Vac 6 A, 50/60 Hz 1W NTC 10K +5...+30 ºC 0.5...4 K resolution 0.1 ºC 0...+40 ºC 10...90% r.h. (non condensing) -20...+70 ºC < 95% r.h. ABS self-extinguished according to UL94 V-0 color (RAL 9010) IP30, class II 144 x 82 x 27 mm 220 g (*) only for models DB-TA-3F3-13A, DB-TA-3F3-19A (**) only for models DB-TA-3F3-13A, DB-TA-3F3-93A (***) remote sensor (optional) Logic of relay outputs Direct action Reverse action Hi1 60 hysteresis 3- POINT ROOM CONTROLLERS DB-TA-3G3-700 FUNCTION - minimum thermostat function with water sensor selectable (4- pipe only); - setpoint adjustment with push-buttons by step 0.1°C. - internal or remote temperature sensor (optional); The thermostat is provided with a LCD display and keys +/- for parameter setting. In normal condition of use the temperature is visualized with a step of 0.1°C. 3- point valves control on 2- or 4- pipe fan coil for room temperature applications with: 2- or 4- outputs for valves, opening and closing, energy saving (activated only in the proportional band); - proportional bands adjustable; - dead zone adjustable (4- pipe); - manual selection of 3- speed motor and thermostatic, continuous or off ventilation selectable; - stroke time valves adjustable; - manual or automatic season change over by remote water sensor (2- pipe only); TYPE 3- SPEED 2- OR 4- PIPE • • DB-TA-3G3-700 On request: optional remote 1 m cable sensor, selectable by jumper; ordering code: NTA010-623. TECHNICAL FEATURES Power supply: Outputs: Speed selector: Power cons.: Sensor: Water sensor: Range: Display: Working: Storage: Housing: Protection class: Size: Weight: ELECTRICAL WIRING 230 Vac ± 10%, 50-60 Hz 5 relays SPST 230 Vac 5 A 230 Vac 5 A 1W NTC 10K NTA020-027P (optional) +5...+30 °C resolution 0.1 °C 0...+40 °C 10...90% r.h. (non condensing) -20...+70 °C < 95 % r.h. ABS self-extinguished according to UL94 V-0 color (RAL 9010) IP30, class II 144 x 82 x 27 mm 220 g 2- pipe system (*) remote air sensor (optional) (**) water sensor (optional) 4- pipe system (*) (**) remote air sensor (optional) water sensor (optional) 61 ROOM CONTROLLERS WITH AUTOMATIC SPEED AND ECONOMY FUNCTION DB-TA-3D3-00A FUNCTION 2-, 4- pipe and 3- speed fan coils control for room temperature regulation: - local or remote changeover based on temperature water supply for 2- pipe system or based on room temperature for 4- pipe systems; - automatic 3- speed selection based on room temperature and setpoint or continuous selectable speed; - additional electric heater control; - dirty filter managemement with operating fan hours indication and dirty filter signalling; - minimum thermostat temperature activation selectable for 4- pipe systems; - hot start management for 2- pipe systems; - air mixing cycle selectable; - economy function - internal or remote sensor (optional). The thermostat has a LCD display with +/- keys for the selection of parameters, status unit visualization and possible alarm condition indications. In normal conditions of use the room (or water) temperature sensor is visualized with a step of 0.1 ºC. TECHNICAL FEATURES ELECTRICAL WIRING Power supply: Outputs: Power cons.: Sensor: Water sensor: Range: Display: Working: Storage: Housing: Protection class: Size: Weight: 230 Vac ± 10%, 50/60 Hz 5 relays SPST 230 Vca 5 A speed: 230 Vca 5 A, 50/60 Hz 1W NTC 10K NTA020-027P (optional) +5...+30 ºC resolution 0.1 ºC 0...+40 ºC 10...90% r.h. (non condensing) -20...+70 ºC < 95 % r.h. ABS self-extinguished according to UL94 V-0 color (RAL 9010 IP30, class II 144 x 82 x 27 mm 220 g Terminal connections for heating and cooling systems: 2- pipe system (*) remote sensor (optional) with 1 m cable length: NTA010-623 (**) water sensor (optional) (***) remote contact (optional) ECO contact closed: economy function inserted ECO contact open: economy function not inserted Jumper setting: - 4- pipe system J1, J2 closed = internal sensor J1, J2 open = remote sensor The units are factory supplied with internal sensor. (*) remote sensor (optional) with 1 m cable length: NTA010-623 (**) water sensor (optional) (***) remote contact (optional) ECO contact closed: economy function inserted ECO contact open: economy function not inserted 62 ROOM CONTROLLERS WITH AUTOMATIC SPEED AND ECONOMY FUNCTION DB-TA-3D3-00A FUNCTION The water sensor can be used as automatic changeover in 2pipe systems or as minimum thermostat for 4- pipe systems. For 2- pipe systems the working season can be selected by sensing the temperature of water delivered to the fan at the inlet of the valve. With electric heater operating mode: - summer: it is possible to heat when temperature decreases from setpoint of neutral zone value (spring or autumn or offices with different thermical load); - winter: it is possible to have a second heating stage. 2- pipe systems: automatic changeover selection 2- pipe systems: heating with electric heater 2- pipe systems: heating without electric heater 2- pipe systems: cooling and heating with electric heater 2- pipe systems: cooling without electric heater 4- pipe systems: operating mode For 4- pipe systems the season is selected according to room temperature and setpoint with a neutral zone selectable. FUNZIONE ECONOMY The economy function can be inserted manually by parameter or with an external contact when the water sensor is not used for automatic changeover for 2- pipe systems or is not used as minimum thermostat for 4- pipe systems. For 2- pipe systems the working setpoint is the heating or cooling economy setpoint according to the working season. For 4- pipe systems the activation points for heating and cooling move away in order to heat and cool less. 63 DB-CDP SET POINT REMOTE CONTROLS FUNCTION The DB-CDP serie is used as remote setpoint variator and fancoil driver. Temperature visualization (model DB-CDP/Dx) Internal sensor, potentiometer, On/Off and 3 speed switches. TYPE ON/OFF 3 SPEEDS DISPLAY POTENTIOMETER SENSOR analog 10k NTC 10k DB-CDP/N1 DB-CDP/N2 • • DB-CDP/D1 DB-CDP/D2 • • Output: Display: Range: Working: Storage: Housing: Protection: Size: NTC 10k digital 10k NTC 10k • digital 10k NTC 10k OVERALL DIMENSIONS TECHNICAL FEATURES Power supply: analog 10k • model DB-CDP/N: 24/230 Vac +/- 10%, 50-60 Hz model DB-CDP/D: 12 Vac +/- 10%, 50-60 Hz itÂs necessary to use a 230/12 Vac trasformator potentiometer 10kOhm sensor NTC 10k power outputs for models with switches DB-CDP/N2: 230 Vac max. 4 A DB-CDP/D2: 12 Vac max. 4 A display LCD with temperature indication sensed by internal sensor (only model DB-CDP/D) it depends on regulator used temperature -10...+50 °C relative humidity 10...90% r.h. (non condensing) -20...+60 ºC < 95 % u.r. self-extinguishing plastic white (RAL 9010) and gray colour IP30 144 x 82 x 27 mm ELECTRICAL WIRING DB-CDP/N DB-CDP/D Digital potentiometer Sensor 10K 10K Sensor 230/12 Vac 12 Vac 230 Vac Note: the digital potentiometer is not isolated from power supply line. 64