Preview only show first 10 pages with watermark. For full document please download

Plc-cpu-cm1-cp Series

   EMBED


Share

Transcript

FEATURES • • • • • • • DESCRIPTION PLC-CPU-CM1-CP Series Processor Speed: 200ns/Step 32K Steps of Program Memory Abundant IO Capacity (Max. 1,024) Self-Diagnosis Allows for Error Identification Modular Design for Ultimate Flexibility Attachable Flash Memory Over 300 Instructions Available The PLC-CPU-CM1-CP Series CPU product line provides versatility, reliability, and room for expansion. Included self-diagnosis program allows the user to identify any errors in the system quickly and easily. Expansion capabilities include up to 16 base units, each supporting 12 slots. This powerful series support various expansion modules, such as high speed counter modules, digital to analog modules, analog to digital modules, temperature sensing modules and communication modules. The PLC-CPU-CM1-CP Series CPU line supports over 300 instructions and is equipped with a 16 bit processor, allowing for high counter values. The option of additional Flash memory is available for increased flexibility and space (model dependent). APPLICABLE MODULES For the PLC-CPU-CM1-XP series, the CPU and the I/O Modules are sold separately, eliminating any unnecessary features and lowering the overall cost. The basic modules required for operation include a base to house all of the modules, a CPU to process necessary tasks, and a power module to give life to your unit. With these modules you are now ready to add any of the following additional features: Compatible Module Types Base DC Input Module Thermocouple Module Power AC Input Module Thermistor Module Redundancy System DC Input, Relay Output Module Load Cell Module Ethernet Module Relay Output Module High-Speed Counter Module Serial Module Transistor Output Module Data Logger Module CDMA Module AD Converter Module Positioning Module CANopen Module DA Converter Module Expansion Module Profibus Module AD & DA Converter Module BACnet Module Resistance Temperature Detector (RTD) Module L011064 910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com PLC-CPU-CM1-CP Series GENERAL SPECIFICATIONS Items Operating Temp Storage Temp Operating Humidity Storage Humidity Vibration Shocks • • • Specifications -10 ~ 65°C -25 ~ 80°C 5 ~ 95% RH, (Non-Condensing) 5 ~ 95% RH, (Non-Condensing) Intermittent Vibration Frequency Acceleration Amplitude 10 < f 0.075 < 57Hz 57 < f 9.8m/s2 {1G} < 150Hz Continuous Vibration Frequency Acceleration Pulse Width 10 < f 0.035mm < 57Hz 57 < f 4.8m/s2 {0.5G} < 150Hz 2 Peak Acceleration: 147 m/s Duration: 11ms Pulse Wave Type: Half-Sine (3 Times Each X, Y, Z) Square wave impulse noise Impulse Noise Electrostatic Discharge Radiated Electromagnetic Field Noise Fast Transient/Burst Noise Operation Ambience Altitude Pollution Degree Cooling Method Reference - Sweep X, Y, Z Each Direction, 10 Times IEC61131-2 + 2,000V KDT Standard Voltage:4kV (Contact Discharge) 27 ~ 500MHz, 10V/m Power Digital I/O (24V or more) 2kV 1kV IEC 61131-2 Digital I/O (24V or less) Analog I/O Comm. Interface 0.25kV IEC 61131-2 IEC 1000-4-2 IEC 61131-2 IEC 1000-4-3 IEC61131-2 IEC 1000-4-4 Free from Corrosive Gases and Excessive Dust 2,000m or Less 2 or Less Air Cooling L011064 910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com PLC-CPU-CM1-CP Series Specifications Item PLC-CPU-CM1-CP3A/B/P/U Stored Program, Cyclic Operation, Time Driven Interrupt I/O Control Method Interrupt system, Direct by Instructions, Scan Synchronous Batch Processing System Program Language Ladder Diagram (LD), Instruction List (IL) Data Processing Method # of Instructions 16 bit Sequence 55 Instructions Application 389 Instructions Processing Speed 200 ns/Step 32K Steps 16K Steps 512K bytes 256K Bytes Maximum 16 Bases N/A Program Memory Capacity Base Expansion Data Memory Capacity CPU SPECIFICATIONS PLC-CPU-CM1-CP4A/B/C/D/U Operation Method Data Memory Capacity 512K Bytes 256K Bytes X 1,024 384 Y 1,024 384 M 8,192 K 2,048 L 2,048 F 2,048 T 1,024 (10ms and 100ms Option) C 1,024 S 100 Card * 100 Step D 10,000 5,000 Z 1,024 Type On Delay, Off Delay, Integration, Monostable, Retriggerable Timer Timer Range 0.01 ~ 6,553.5 sec Type Up Counter, Down Counter, Up-Down Counter, Ring Counter Counter Coefficient Range -32,768 ~ 32,767 # of Program Blocks 128 Operation Mode RUN, STOP, PAUSE, REMOTE Self Diagnosis Watch-Dog Timer, Memory Error, I/O Error, Battery Error, Power Error, etc. Restart Mode Cold, Warm Battery Back-up Over 3 Years Built-in Function Computer Link (RS232C), Clock (RTC), Program Editable on Run Mode, PID Control (32 Loops), I/O Reservation, USB 2.0 Port L011064 910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com DEVICES & ADDRESSES PLC-CPU-CM1-CP Series Device Description X Input Y Output M Auxiliary Relay K Keep Relay T Timer C Counter D Data Register @D Indirect Data Register L Link Relay S Step Control Relay F Internal Flag (Relay) Type Applicable Devices Addressing Scheme # Of Characters Bit Data X, Y, M, K, L, F [Device] + [Card #] + [Bit #] Card #: 3 decimal characters Bit #: 1 hexadecimal character Word Data D, Z, T, C [Device] + [Card #] Card #: 4 decimal characters Timer T [Device] + [Bit #] Card #: 4 decimal characters Counter C [Device] + [Bit #] Card #: 4 decimal characters S [Device] + [Card #] + [.] + [Step #] Bit Data in Word X, Y, M, K, L, F [Device] + [Card #] + [0] Card #: 3 decimal characters DIMENSIONS Step Controller Card #: 2 decimal characters Step #: 2 decimal characters L011064 910 East Orangefair Ln. Anaheim, CA 92801 *All units are in mm Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com PLC-CPU-CM1-CP Series USB Mini Loader Port COMMUNICATION INTERFACE/SPECIFICATIONS USB Loader Port USB Mini Loader Port Serial Loader Port Push-in Loader Port Part # Description AAUSB-ABMINI-6 72 inch USB-A to USB-B ACCESSORIES Push-in Loader Port PC Serial Port Pin Pin Description PLC Serial Port Pin Pin Description 5 Ground 3 Ground 3 TX 1 RX 2 RX 2 TX Part # Description AA9MFC-6 72 inch RS232 cable Model Description CM0-DM Dummy Module for empty slot CM1-FM512 Flash Memory Pack CM0-CBE05 Expansion Cable CM0-BAT CPU Battery for Data Backup L011064 910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com PLC-CPU-CM1-CP Series The XP Series of CPU’s allows up to 16 Base expansions Model Type Specification CM1-EP01A CM1-EP02A 1 expansion port, no expansion hub 2 expansion ports, expansion hub embedded Expansion CM1-EP03A 3 expansion ports, for redundant CPU configuration Supports high-speed expansion communication of 10 Base-T Local EXPANSION CAPABILITIES Expansion #1 Expansion #2 100m Built-in network repeater Expansion of remote I/O function Maximum distance between segments is 100m Maximum distance of entire expansion is 1,600m Expansion #3 Expansion number set by rotary switch Expansion #14 Expansion #15 Expansion #16 L011064 910 East Orangefair Ln. Anaheim, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com