Preview only show first 10 pages with watermark. For full document please download

Plc Stamp 1200 Micro Evaluation Kit Datasheet

   EMBED


Share

Transcript

PLC Stamp 1200 micro Evaluation Kit Datasheet I2SE GmbH June 28, 2017 1/9 CONTENTS CONTENTS Contents 1 Revisions 3 2 Introduction 2.1 Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 4 3 Overview 4 4 main PCB 4.1 Power Supply . . . . . . . 4.2 Switches . . . . . . . . . 4.3 Connectors . . . . . . . . 4.4 Transformers . . . . . . . 4.5 Powerline Coupling . . . . 4.6 Dead Wire Communication . . . . . . 5 5 6 6 6 7 8 5 Ethernet Daughter Board 5.1 Power On Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3 Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 8 9 9 6 Software 9 7 Contact 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2/9 2 1 Revisions Revision 3 Release Date June 28, 2017 2 1 March 27, 2017 February 17, 2017 2 INTRODUCTION Changes added GPIO# to LED behaviour table, added GPIO Test feature, added Dead Wire Communication and Power Supply sections added content of the kit initial release Introduction R The PLC Stamp 1200 micro gives your application access to powerline communication based on the HomePlug TM AV2 Chip QCA7500. You can realize point-to-point and multi-point connections depending on your application. The data will be transmitted as Ethernet packets over the power line. This gives you the opportunity to use TCP/IP or whatever network protocols you wish to use. The evaluation kit includes the PLC Stamp 1200 micro evaluation board as well as an Ethernet daughterboard - this is everything you need for evaluation of power line communication with the PLC Stamp 1200 micro. The evaluation board contains the required galvanic isolation from the power line as well as the power supply. The segmentation into the evaluation board and daughter board was done to allow you to test other modes of the QCA7500 as well as to design your own prototypes based on your favorite hardware on the R(G)MII signals. The included daugther board is used to configure and demonstrate the QCA7500 MAC mode and includes Buttons and LEDs for interaction with the user. Features: R AV2TM compatible PLC-Chip QCA7500 • based on the HomePlug • suitable for direct connection to mains/powerline • integrated galvanic isolation • internal power supply • accessible GPIO / RGMII-Interface Parameter Power supply Power consumption Data rate powerline Data rate ethernet Reach Outline dimension RoHS Value 230 V ˜ 50 Hz; 110 V ˜ 60 Hz 2.5 W (idle) to 3.5 W (transmitting) with Ethernet daughter board max. 1200 MBit/s max. 1000 MBit/s maximal 300 m over the Powerline 143 mm x 112 mm x 40 mm PLC Stamp 1200 micro evaluation kit is manufactured RoHS compliant. Kit Content: • 1x PLC Stamp 1200 micro • 1x PLC Stamp 1200 micro EVB • 1x PLC Stamp 1200 micro EVB Ethernet daughter board • 1x IEC mains cable • 2x Ethernet cable • 1x Gigabit Powerline Adapter 3/9 2.1 Handling 3 OVERVIEW Figure 1: image of PLC Stamp 1200 micro EVB with Ethernet daughter board 2.1 Handling This electronic component is sensitive to electrostatic discharge (ESD). The circuitry on the board can be connected to mains voltage. To avoid electrical shock do not use this product while the enclosure is opened. 3 Overview The block diagram in Figure 2 shows the components included on the evaluation board additionally to the PLC Stamp 1200 micro. The only required connections are IEC connector for the power supply and a RJ45 ethernet cable to a gigabit ethernet enabled device. 4/9 4 MAIN PCB Figure 2: block diagram PLC Stamp 1200 micro EVB with Ethernet daughter board 4 4.1 main PCB Power Supply The PLC Stamp 1200 micro EVB can be powered via mains voltage over a standard IEC connector. But under some circumstances it may be necessary to connect an external power supply to the module directly instead of the mains voltage. The external supply can be connected to JP2(+3V3) and JP4(GND) as shown in Figure 3. Please refer to PLC Stamp 1200 micro datasheet for power supply requirements. Figure 3: External Supply Connection 5/9 4.4 Transformers 4.2 Switches 4 MAIN PCB The main PCB of the EVK has two switches. SW1 is connected to the QCA7500 GPIO0. While the QCA7500 is booting and this switch is pressed QCA7500 will enter the bootloader mode. SW2 is connected to the QCA7500 reset pin. 4.3 Connectors The main PCB of the evaluation board has two connectors. One IEC connector for the power line and powerline network and the other one to connect a daugther board. The IEC has the standard pin out for mains with L, N and PE. Daughther board connector: The daugther board connector is a hermaphroditic Samtec LSS-130-02-L-DV-A connector. Pin 1 of the main PCB connects to pin 2 of the daugther board PCB. X1 Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Name not connected not connected GND GND PHY CLK PHY MDC GND GND !PHY RST PHY MDIO GND GND GPIO 0 MTX D3 GND X1 Pin 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Name GND GPIO 9 MTX D2 GND GND GPIO 6 MTX D1 GND GND GPIO 7 MTX D0 GND GND GPIO 8 MTX CLK X1 Pin 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 Name GND GND GPIO 10 MTX CTRL GND GND GPIO 4 MRX D3 GND GND not connected MRX D2 GND GND GPIO 3 X1 Pin 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 Name MRX D1 GND GND GPIO 2 MRX D0 GND GND GPIO 1 MRX CLK +3V3 GND +3V3 MRX CTRL +3V3 GND Table 4: Daugther Board Connector main PCB side Nomenclature GPIO x QCA GPIO # x PHY* PHY RGMII Controlling Signals M*X * RGMII Signals GND Ground +3V3 Supply for daugther board 4.4 Transformers The evaluation board contains two transformers with 1:3:4 (TX:PL:RX) turns ratio for MIMO and SISO coupling. The powerline signals can be disconnected from mains by removing all the 0 Ohm resistors (Figure 4 R2,R3,R9, R10,R11,R13,R14,R15) between PLC Stamp 1200 micro and the coupling transformers TR1, TR2. For MIMO Powerline Communication both transformers should be connected to 0 Ohm resistors between PLC Stamp 1200 micro and the coupling-transformers. For SISO Powerline Communication only the transformer TR1 should be connected. TR1 is for coupling the powerline signals between mains L and mains N. TR2 couples the powerline signals between mains L and mains PE. 6/9 4.5 4.5 Powerline Coupling 4 MAIN PCB Powerline Coupling To get the AV2 signals on the mains wires you have to couple them via various components. The schematic in this section shows a possible connection to mains. The optocoupler for zero cross detection always needs to be connected to mains if you need it. Figure 4: PLC Coupling circuitry For further information about the coupling circuit please refer to the Qualcomm Atheros QCA7500 documentation or contact I2SE for design support. 7/9 4.6 4.6 Dead Wire Communication 5 ETHERNET DAUGHTER BOARD Dead Wire Communication To enable dead wire communication (the communication over otherwise unused wires) and disable PLC coupling to mains voltage desolder resistors R16 ... R21 as shown in Figure 4. Those resistors are located on the PCB as shown in the assembly plan Figure 5 marking a). The dead wires can now be connected to the wire pads marked in the assembly plan Figure 5 marking b). You do not need to solder anything to ”PE” if you want to use a two wire connection opposed to a three wire (MIMO) connection. However: please be aware of the degradation in performance if doing so. Figure 5: Dead Wire Communication Connection Please note that you void the warranty of the product if you choose to desolder these resistors. 5 Ethernet Daughter Board Figure 6: Ethernet Daughter Board 5.1 Power On Configuration The Power On Configuration for PLC Stamp 1200 micro is done with pull up and pull down resistors on the Ethernet daugther board for MAC mode and RGMII speed. 8/9 7 5.2 CONTACT LEDs LED Power pairing PLC Stat PLC Act Eth Act PLC fast PLC slow PHY Act 1000 10/100 Function Power* Pairing* PLC Status* PLC Activity* Ethernet Activity* PLC Throughput* PLC Throughput* Ethernet PHY Activity Ethernet PHY Gigabit/s Link Ethernet PHY 10/100 Mbit/s Link Behavior On / Off Pulse 500ms/500ms On / Off Pulse 60 ms / 60 ms Pulse 60 ms / 60 ms High On, mid On, low Off High Off, mid On, low On Pulse On / Off On / Off QCA7500 GPIO# 0 2 6 7 8 9 10 - Table 7: LED behaviour *: will also blink one time at power up. 5.3 Switches SW1 is connected to QCA7500 GPIO 1. SW2 is connected to QCA7500 GPIO 4. Switch 1 can execute different functions dependent on the pressing time. Switch 2 executes a GPIO test feature. The GPIO test feature flashes all QCA7500 connected LEDs one time with 500 ms on and 500 ms off time. Switch SW1 SW1 SW1 SW2 Holding Time / s 1 8 13 1 Function Pairing Network Membership Key Randomization Factory Default GPIO test feature* *: this GPIO test feature is available on PLC Stamp 1200 micro evaluation boards with MAC higher than 00:01:87:0B:00:9C 6 Software The PLC Stamp 1200 micro EVB comes with firmware and settings flashed that enable you to get it up and running with the Ethernet PHY daugther board as fast as possible. Users who want to use it with PHY mode may need other settings. 7 Contact Website: http://www.i2se.com I2SE GmbH Friedrich-Ebert-Str. 61 04109 Leipzig Germany 9/9