Preview only show first 10 pages with watermark. For full document please download

Plots 14-17 - Help To Buy South

   EMBED


Share

Transcript

W8 1200x1050 1500 skilling line 1200 skilling line 2278 skilling line 2278 skilling line 1500 skilling line 1200 skilling line PIR Low Energy Light HA (RENTED) PIR 2000 x 2500 Living space activity zone 4p Dwelling Fused spur to electric fire to be positioned 1000mm Low from centre of room. Fused spur to electric fire to be positioned 1000mm from centre of room. RWP Energy Light Focal Point 750 Diameter Coffee Table Fused spur to electric fire to be positioned 1000mm from centre of room. For future fire Fused spur to electric fire to be positioned 1000mm from centre of room. PIR Low RWP PIR Low RWP Energy Light For 2 Focal Point RWP Energy Light For Focal Point future fire future fire Table & Stool Visitors Chair RWP future fire 2000 Storage 750 Diameter Coffee Table E Visitors Chair Occa Table Occa Table Visitors Chair 2 Occa Table E Visitors Chair Wardrobe Single 2 2 2 800 x 1350 Dining Table 5 4 LE Recirculation cooker hood 2 4 GR 2 1 Recirculation cooker hood S f/f space 750mm Clear Space Wheelchair turning/ kitchen activity zone 750mm Clear Space BT w/m space F RWP BT System 1 Photocell Low GR N System 1 Recirculation cooker hood N F F S d/w space 2 2 System 1 shelving to linen cupboard on side battens screwed & plugged to stud work f/f space 3 w/m space G 25 P G 7 7 6 6 5 5 4 4 3 3 2 2 1 1 Extraction cooker hood 24 Sockets on party walls to be carefully located to avoid back to back positions when the wall is chased for conduit and socket boxes. w/m space RWP F w/m space 2 System 1 BT Photocell Low Energy Light Energy Light Code 3 Water Usage - Housing Association Plots Water Flow Rate & Fill Capacity Schedule All WC's Dual flush 4/2.6 litres capacity (max.) All whb taps: 4 litres I minute flow rate (max.) All kitchen I utility sink taps: 4 litres I minute flow rate (max.) All baths: 130 litres capacity (max. to overflow) All showers: 6 litres I minute flow rate (max.) 18 760 x 560mm Access Hatch Code for Sustainable Homes Notes - Code 3 Ene 4 Refer to External Works drawing for locations of Rotary Lines, spikes to be concreted in place Ene 5 All supplied White Goods to be minimum A Rated Ene 6 Provide dedicated energy efficient fittings. PIR sensors to rear doors and dawn to dusk cut off control to front doors. Provide vacuum or timer switches to low energy CFL lamp bulbs to communal areas. Ene 8 760 x 560mm Access Hatch Drawers P BT Photocell Low RWP All porch lights and external lights elsewhere to be Photocell manually switched. 19 System 1 RWP Low Energy lamps required in all fittings. UP 17 S 2 G 21 20 700 x 1100 Dressing Space GR d/w space P R/A N d/w space Photocell Low Energy Light G W7 RWP 1200x1050 sheds to be fitted with a steel cycle hoop bolted down to the concrete base slab. Ene 9 Provide a home office to be located in a bedroom other than the master bedroom for dwellings with three or more bedrooms, or to be located in either the living room or bedroom or dining area for dwellings with two or less bedrooms or studio homes. Home office to have minimum 2no. double sockets and either 2no. telephone points or 1 no. telephone point if the dwelling has access to cable or broadband service. Home office to have an openable window with average daylight factor of 1.5% and a minimum wall length of 1.8m. Wat 2 Provide detachable water butts connected to the down pipe with automatic overflow into the rainwater system with a tap and child proof lid, as follows: 3 and 4 bed homes with private garden -200 litres minimum Apartments to be fitted with 2no. 200 lire butts for communal use Refer to External Works and Drainage drawings for locations. Was 1 Provide 3No internal recycling bins with a total of 30 litres min, capacity with no single bin smaller than 7 litres capacity to be located & fixed in a dedicated kitchen cupboard under the sink or another cupboard next to a non-recyclable waste bin. Was 3 Entrance door to have a level threshold in order to provide accessibility to the external compost bin for disabled people. Refer to External Works drawings for locations. Man 4 All external and apartment entrance doors long with all ground floor windows to be Secure by Design Compliant and Certified. Second Floor Electrics Energy Light Ground Floor Electrics REFER TO KITCHEN SUPPLIERS LAYOUT FOR KITCHEN DESIGN Electrical Symbols Legend All electrical work should meet the requirements of Part P Building regulations and must be designed, installed and tested by a person competent to do so. A certificate of electrical installation must be issued on completion. 2 way Switch GR Grid switch control panel Thermostat mounted 1050 above f.f.l. mounted 1050 above f.f.l. F Ceiling mounted extract fan S Fully automatic smoke detector to BS 5446 (minimum 2No.) interlinked and hardwired to mains P M.J. M.J. RWP Battery operated carbon monoxide detector fitted in accordance with manufacturers instructions Track lighting with spot lights Bell push Low Energy Recessed downlight Bell sounder E Drawers D8 Indicative boiler position Batten holder lamp Radiator ED Energy display device UP 700 x 1100 Drying space 600 x 700 Using 9mm Plywood lining to WC full face of all bathroom walls TBV D6 11 D6 10 7 Double Wardrobe Table & Stool Electrics for 'Home Office' 700 x 1100 Dressing space 700 x 1100 Dressing space Double Wardrobe Double Wardrobe A Energy display device added MG 26/03/15 AMENDMENTS BY DATE R/A F Drawers Double Wardrobe TBV Single Wardrobe S S 3 No. slatted shelving to cupboard on side battens screwed & plugged to stud work, 450 c/c vertically D5 R/A D4 Drawers 700 x 1100 Dressing space 13 11 10 10 Double Wardrobe 9 R/A D5 12 11 19 18 16 17 700 x 1100 Dressing space Low level boxing to waste pipework 8 8 7 6 6 TBV D4 Double Wardrobe 9 7 System 1 Electric shower over bath 3 No. slatted shelving to cupboard on side battens screwed & plugged to stud work, 450 c/c vertically Drawers W4 W3 1200x1200 W5 (#) M.J. 2.25m2 slatted shelving to cupboard on side battens screwed & plugged to stud work, 450 c/c vertically 2.25m2 slatted shelving to cupboard on side battens screwed & plugged to stud work, 450 c/c vertically M.J. 1135 x 1200 Table & Stool RWP 700 x 1100 Dressing space 700 x 1100 Dressing space W4 (#) 1135 x 1200 700 x 1100 Dressing space Table & Stool RWP M.J. W3 (#) 1135 x 1200 W4 572 x 1200 RWP M.J. Design Lab Architectural Services 65 Oxford Road Canterbury Kent CT1 3QP Tel . no : 01227 478974 Email : [email protected] Drawn : MG Date : Scale : 1:50 Checked :MG FEB 2014 Title : Electrics for 'Home Office' 700 x 1100 Dressing space 1200x1200 700 x 1100 Dressing space D8 Single Wardrobe Electrics for 'Home Office' First Floor Electrics Full height Boxing to rear of WC 15 700 x 1100 Dressing space Drawers 13 12 D8 Single Wardrobe svp 9mm Plywood lining to full face of all bathroom walls D6 5 D8 UP Electric shower over bath D7 21 2 2 2 D6 22 S 700 x 1100 Dressing space Full height Boxing to rear of WC D7 2 9mm Plywood lining to full face of all bathroom walls Low level boxing to waste pipework Drawers 6 Table & Stool GROUND FLOOR ELECTRICAL LAYOUTS svp 12 D5 M.J. Drawers D7 13 8 RWP Drawers 700 x 1100 Dressing space 2 No. slatted shelving to linen cupboard on side battens screwed & plugged to stud work 9 Note dimensions shown are to u/s of electrical plate PLOTS 14-17 RWP REV S svp INSTALLED BOILER TO HAVE A DRY NOX LEVEL OF LESS THAN OR EQUAL TO 40 mg/kWh. W5 (#) 1135 x 1200 M.J. RWP 12 3 No. slatted shelving to cupboard on side battens screwed & plugged to stud work, 450 c/c vertically Full Height Boxing to end of bath A SUITABLE NUMBER (AT LEAST ONE ON EACH FLOOR) OF SELF CONTAINED SMOKE ALARMS MUST BE INSTALLED. THE ALARMS SHOULD BE INTERCONNECTED AND FIXED TO THE CEILING IN A CENTRAL POSITION BUT AT LEAST 300MM FROM ANY LIGHT FITTING. THE ALARM MUST BE FIXED STRICTLY IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. W6 572 x 1200 700 x 1100 Dressing space D5 13 10 Pelmet lights mounted under kitchen cabinets, wired supply only Table & Stool Drawers TBV In-line thermostatic blending valve to limit hot PIR to external lamps Full height Boxing to end of bath Table & Stool Fluorescent luminaire RWP M.J. 572 x 1200 1135 x 1200 14 11 Immersion heater W6 W5 (#) RWP 2 D7 Low Level Boxing to waste pipework External tap IP24 Rated 60we external lamp with integral photocell RWP M.J. Electrics for 'Home Office' 600 x 1200 Cot Space D4 F Pendant lamp (to be fitted with a low energy bulb) IP44 Rated Batten Lamps W6 (#) 1135 x 1200 Electricity Meter as shown Internally 2 IP TBV Home Network Socket CAT 5 W7 572 x 1050 svp 700 x 1100 Dressing space Boiler programmer CO IP44 Rated Low Energy Recessed downlight 700 x 1100 Drying space Electric shower over bath Consumer unit & DB (distribution board) Telephone master socket Table & Stool Telephone junction box mounted 450 above f.f.l. mounted 450 above f.f.l. mounted 450 above f.f.l. 600 x 1200 Cot Space Digital TV outlet Double Wardrobe Cooker control panel RWP System 1 Shaver socket blank W6 1200x1200 Pull switch Fused connection to boiler where applicable mounted 1800 above f.f.l. mounted 1050 above f.f.l. W5 1200x1200 Tubular Heater 2 mounted 1050 above f.f.l. mounted 1050 above f.f.l. Table & Stool Switch Tubular Heater Twin switched mounted 450 above socket outlet 13A f.f.l. Twin switched mounted 1050 socket outlet 13A above f.f.l. 13A socket in separately switched appliance space from grid ring 13A socket in separately appliance space switched Fused switch to cylinder / cooker hood & extract fans (N) = Neon indicator 2. All dimensions are in millimeters unless stated otherwise All sockets, switches, thermostats, controls, TV points, Telephone sockets etc. will be positioned between 450mm and 1200mm above floor level on all floors. (Bottom of sockets 450mm above floor level, top of sockets no more than 1200mm). svp f/f space f/f space GR P S 22 Wheelchair turning/ kitchen activity zone LE 26 D9 F d/w space DRAWING STATUS: 23 LE RWP 27 6 5 ED F 28 D10 ED 2 S CO N F 800 x 1350 Dining Table 7 3 1 2 N Table & Stool f/f space 800 x 1350 Dining Table Automatic smoke detectors (with sounders) to BS 5446 Part 1, to be installed. There should be at least one detector on each storey. Smoke alarms to be inter-connected and wired to a separate fused circuit with battery back up all in accordance with Building Regulations Schedule B and Approved Document B1. D11 ED 7 5m 1. DO NOT SCALE 2 ED 4m GENERAL NOTES Visitors Chair 2.25m2 slatted shelving to cupboard on side battens screwed & plugged to stud work, 450 c/c vertically 3m After installation then ventilation system is to be tested by a competent person from a recognised organisation and a certificate duly issued. 3.0m2 slatted shelving to cupboard on side battens screwed & plugged to stud work, 450 c/c vertically 2m TENDER Visitors Chair 2 Scale 1:50 Fans to be either ducted through ceiling to outside wall, through roof space to vent tile or wall mounted direct through external wall. Where ducted through roof space, duct to be insulated. Where ducted to eaves provide anti-infestation mesh. For location refer to plans and elevations drawing. Single Wardrobe 800 x 1500 Dining Table Visitors Chair 750 Diameter Coffee Table 2000 Storage 1000 Storage 750 Diameter Coffee Table 2000 x 2500 Living space activity zone 5p Dwelling Refer to Greenwood Airvac information for housetype specific ventilation requirements 700 x 1100 Dressing space Drawers Visitors Chair 2000 x 2500 Living space activity zone 5p Dwelling 100mm @ A1 Fans and accessories to be used for System 1 are Greenwood Airvac: AXS100TR: Select 100mm single speed fan with timer & remote operation. S/RF90T: 100mm centrifugal fan with timer surface mounted or recessed. S/RF90B: 100mm centrifugal fan basic surface mounted or recessed. RWP 2000 x 2500 Living space activity zone 5p Dwelling Background ventilators: to be as Table 5.2a with 5000 mm2 minimum equivalent area in each habitable room and 2500 mm2 minimum equivalent area in each wet room. All ventilators to be located 1.7m above FFL For Focal Point 2000 Storage RWP ELECTRICAL Electrical installation to Building Regulations Approved Document P, NHBC standards and IEE Regulations for Electrical equipment of Buildings (Latest edition) and BS7671 2001. System 1 background ventilators and intermittent extract fans fully in accordance RWP Tubular Heater 1000 Storage RWP Table & Stool PLOTS 14-17 GROUND, FIRST & SECOND ELECTRICAL LAYOUTS Job : W4 572 x 1200 W3 (#) 1135 x 1200 RWP HATCHWOOD FARNHAM ROAD, ODIHAM Drg. No : Rev : Plots 14-17 - 014 A Dwg file name: A1 Copyright Reserved Design Lab Architectural Services