Preview only show first 10 pages with watermark. For full document please download

Plug-in Modules For Gamma

   EMBED


Share

Transcript

broadband distribution node GAMMA - PLUG-IN MODULES PLUG-IN MODULES FOR GAMMA OFR 870-SCA , OSR 870-SCA Optical receiver and optical redundant receiver module PARAMETER VALUE Wavelength [nm] COMMENT 1100 ÷ 1600 -5 ÷ +2 Optical input power range [dBm] 47 ÷ 870 Bandwidth [MHz] ≤8 Equivalent input noise [pA/ Hz ] Optical connector Others on request SC/APC Optical power test point [V/mW] 1 ± 10% RF level at the output of the u module [dBuV] 78 ± 1 4,5% OMI/channel, 0dBm input optical power Optical Power Indicator [dBm] -5 Green - optical power > -5dBm Red - optical power < -5dBm RF test point - directional [dB] -20 Relative to module output signal BLOCK DIAGRAM 1V/mW To AGC LOGIC optical input 1 O optical input 2 O E TP -20dB RFout A/B switch E OSR 870 (OPTION) CNR [dB] CNR vs.optical input power and OMI /channel 5% 4,5% 4% 3,5% POPT [dBm] ul.Sêdzickiego 13, 81-374 Gdynia, Poland tel. +48 58 / 661 50 00, fax +48 58 / 620 75 50 e-mail: [email protected]; http:// www.vector.com.pl 06.02.2002; page 2 of 8 PLUG-IN MODULES FOR GAMMA ORT-F1310 SCA NADAJNIK OPTYCZNY ORT-F1310-SCA Optical transmitter module PARAMETER VALUE Laser type COMMENT FP 1310 ± 40 Wavelength [nm] 0±1 Optical output power [dBm] Bandwidth [MHz] 5 ÷ 210 For external input - port 1 Bandwidth [MHz] 5 ÷ 65 For internal RF input Minimum input level for NPR > 30dB [dBuV/Hz] u 16 RF drive for laser @ 25 C, 5dB optical loss, 60MHz load NPR > 30dB dynamic range [dB] 20 @ 25 C, 5dB optical loss, 60MHz load 0 0 SC/APC Optical connector Others on request Laser power status indicator [dBm] -3 Green - optical power > -3dBm Red - optical power < -3dBm RF test point - directional [dB] -20 Signal level to laser Insertion loss for external RF input [dB] -3,5 For external input - port 1 OMI variation over temperature [dB] ±2 BLOCK DIAGRAM NMS CONNECTOR OLPA (option) TX optical power TX Current OLP Optical Output O REV PAD RF in E TP -20 dB External RF input 5-210 MHz EXT. REV PAD RRG NPR vs. RF level for FP laser NPR [dB] 50 40 30 20 10 20 30 40 Transmitter input RF level [dBµ V/Hz] 60MHz load ul.Sêdzickiego 13, 81-374 Gdynia, Poland tel. +48 58 / 661 50 00, fax +48 58 / 620 75 50 e-mail: [email protected]; http:// www.vector.com.pl 06.02.2002; page 3 of 8 PLUG-IN MODULES FOR GAMMA ORT-D1310-SCA Optical transmitter module PARAMETER VALUE COMMENT DFB Laser type 1310 ± 40 Wavelength [nm] 0±1 Optical output power [dBm] Bandwidth [MHz] 5 ÷ 210 For external input - port 1 Bandwidth [MHz] 5 ÷ 65 For internal RF input Minimum input level for NPR > 35dB [dBuV/Hz] u 10 RF drive for laser @ 25 C, 5dB optical loss, 60MHz load NPR > 30dB dynamic range [dB] 20 @ 250C, 5dB optical loss, 60MHz load 0 SC/APC Optical connector Others on request Laser power status indicator [dBm] -3 Green - optical power > -3dBm Red - optical power < -3dBm RF test point - directional [dB] -20 Signal level to laser Insertion loss for external RF input [dB] -3,5 For external input - port 1 OMI variation over temperature [dB] ±2 BLOCK DIAGRAM NMS CONNECTOR OLPA (option) TX optical power TX Current OLP Optical Output O REV PAD RF in E TP -20 dB External RF input 5-210 MHz EXT. REV PAD RRG NPR vs. RF level for DFB NPR [dB] 50 40 30 20 0 10 20 30 40 Transmitter input RF level [dBµ V/Hz] 60MHz load ul.Sêdzickiego 13, 81-374 Gdynia, Poland tel. +48 58 / 661 50 00, fax +48 58 / 620 75 50 e-mail: [email protected]; http:// www.vector.com.pl 06.02.2002; page 4 of 8 PLUG-IN MODULES FOR GAMMA AGC xxx - 6 Automatic gain control module controlled by pilot tone TECHNICAL PARAMETERS 85 ÷ 862 Bandwidth [MHz] Pilot frequency [dB] xxx Video carrier to pilot tone ratio [dB] 0 ÷ 16 3 dB bandwidth (minimum) [MHz] Dynamics [dB] 8 AGC insertion loss [dB] 2 Level stability over 8 dB input level change [dB] ±1 4 20 dB bandwidth [MHz] 15 BLOCK DIAGRAM xxx (MHz) RFin Detector Us Switch RFin Variable attenuator -2dB ÷ -10dB RFout AGC 000 - 6 Automatic gain control module controlled by input optical power level to optical receiver TECHNICAL PARAMETERS Bandwidth [MHz] 85 ÷ 862 Dynamisc [dB] 8 AGC insertion loss [dB] Level stability over 8 dB input level change [dB] 2 ±1 BLOCK DIAGRAM Uin from optical receiver Us Switch RFin Variable attenuator -2dB ÷ -10dB RFout ul.Sêdzickiego 13, 81-374 Gdynia, Poland tel. +48 58 / 661 50 00, fax +48 58 / 620 75 50 e-mail: [email protected]; http:// www.vector.com.pl 06.02.2002; page 5 of 8 PLUG-IN MODULES FOR GAMMA RCA schemat blokowy Output module for coaxial reverse output REQ REV PAD5 REV main board output 1 RJG TP1 -20 dB REV EQ PAD FUSE PORT1 PORT1 FUSE PORT1 spring contact on RCA FUSE PORT1 spring contact on main board CKG 01 Optical Node Conversion Kit Kit includes: - optical input adapter PG-16 - cover plate - fibre holders - mounting screws RAG 29-1 Reverse amplifier module with low pass filter for single reverse path TYP MODU£U Maximum gain for configuration module RCG 04 [dB] Bandwidth [MHz] Flatness [dB] Noise figure for configuration module RCG 04 [dB] NPR for 60 MHz load @ 27dBµV/Hz [dBc] TECHNICAL PARAMETERS 30 ± 0,75 5 ÷ 65 ± 0,7dB ≤ 6dB ≤ -60dBc SCHEMAT BLOKOWY 4 3 Intermodulation distortions: • third order beat IMD3 [dBc] @ 110dBµV [dBc] • second order beat IMD2 [dBc] @ 110dBµV [dBc] Power consumption [W] ≤- 60 2 1 ≤- 60 2,4 RAG 29-2 Reverse amplifier module with low pass filter for dual reverse path TYP MODU£U Maximum gain for configuration module RCG 04 [dB] Bandwidth [MHz] Flatness [dB] Noise figure for configuration module RCG 04 [dB] NPR for 60 MHz load @ 27dBµV/Hz [dBc] TECHNICAL PARAMETERS 2 x 30 ± 0,75 SCHEMAT BLOKOWY 3 2 1 Intermodulation distortions: 5 ÷ 65 • third order beat IMD3 [dBc] @ 110dBµV [dBc] ± 0,7 • second order beat IMD2 [dBc] ≤6 @ 110dBµV [dBc] ≤ -60 4 Power consumption [W] ≤- 60 ≤- 60 2,4 ul.Sêdzickiego 13, 81-374 Gdynia, Poland tel. +48 58 / 661 50 00, fax +48 58 / 620 75 50 e-mail: [email protected]; http:// www.vector.com.pl 06.02.2002; page 6 of 8 PLUG-IN MODULES FOR GAMMA RCG 01 4 Reverse configuration module Used for 3-outputs distribution amplifier or 3-outputs optical node with single reverse path. Provides equal sum of ports 2, 3 and 4. 3 2 RCG 02 Reverse configuration module Used for 3-outputs optical node with dual reverse path. Provides equal sum of ports 2 and 3. Port 4 is configured as an independent reverse path. 5 1 4 3 2 RCG 03 5 1 4 3 Reverse configuration module Used for 2-outputs distribution amplifier or 2-outputs optical node with signle reverse path as well as for 3-outputs optical node with dual reverse path. Provides equal sum of ports 3 and 4. Port 2 is configured as an independent reverse path (for 3-outputs optical node). 5 1 RCG 04 4 3 2 Reverse configuration module Used for 2-outputs optical node with dual reverse path. Ports 3 and 4 are configured as independent reverse paths. 2 5 RCG 05 3 4 Reverse configuration module Used for 3-outputs optical node with dual reverse path. Allows redundant transmission while using redundant optical transmitter. 1 2 RCG 06 Reverse configuration module Used for 2-outputs optical node with dual reverse path. Allows redundant transmission while using redundant optical transmitter. 5 1 4 3 2 1 5 ISG 65 Ingress switch module Used while interacting with Network Management System via NMS transponder. Allows ingress source detection/preventing by remote control of 3-state ingress switches insertion loss 0 / 6 / 30 dB. There is no need to plug any additional modules, while ingress switch module is not installed autolink circuit provides connectivity automatically. 0 / 6 / Off OLPA 65 Active band-pass filter module 15÷65 MHz for optical transmitter Provides gain of 20 dB. ul.Sêdzickiego 13, 81-374 Gdynia, Poland tel. +48 58 / 661 50 00, fax +48 58 / 620 75 50 e-mail: [email protected]; http:// www.vector.com.pl 06.02.2002; page 7 of 8 PLUG-IN MODULES FOR GAMMA RHP 15 High pass filter 15MHz module for reverse path RRG xxx Single tone reference generator module xxx - frequncy tone [MHz] , REO 65 Reverse path equalizer module Equalization is determined by ATG 8xx attenuator (REV EQ PAD) RJP Reverse jumper DF 65 A Diplex filter module Frequency range: 5 ÷ 65 / 85 ÷ 862 MHz ATG 800 ÷ ATG 820 Attenuator module Used in forward and reverse path. Attenuation range 0 ÷ 20dB with 1dB step EQ 801 ÷ EQ 824 Forward path equalizer module Equalization range 1 ÷ 24dB with 1dB step AT 800 Forward jumper Installed in place of diplex filters and/or forward equalizers if they are not used ATG 075 Terminator 75 Ω PSG 65 Switch mode power supply (SMPS)module 35 ÷ 65 VAC DC Voltage SMPS AC IN PSG 90 Switch mode power supply (SMPS) module 40 ÷ 90VAC DC Voltage SMPS AC IN Sêdzickiego 13, 81-374 Gdynia, Poland tel. +48 58 / 661 50 00, fax +48 58 / 620 75 50 e-mail: [email protected]; http:// www.vector.com.pl 06.02.2002; page 8 of 8