Transcript
PLUGGABLE I/O SOLUTIONS
FOR MORE INFORMATION Technical Support Internet: USA: Canada: Mexico & Central America: South America: Germany: UK: France: Netherlands: China:
www.tycoelectronics.com/help +1 (800) 522-6752 +1 (905) 470-4425 +52(0) 55-1106-0814 +55 (0) 11-2103-6000 +49 (0) 6251-133-1999 +44 (0) 8706-080208 +33 (0) 1-3420-8686 +31 (0) 73-6246-999 +86 (0) 400-820-6015
Part numbers in this brochure are RoHS Compliant*, unless marked otherwise. *as defined www.tycoelectronics.com/leadfree
Quick Reference Guide
Pluggable I/O Solutions The pluggable I/O interface offers significant advantages as a high speed I/O interconnect. With a standard equipment I/O interface and the flexibility of pluggable modules, come the options for fiber and copper links, and various data rates and protocols. Tyco Electronics has always been a leader in the development of pluggable I/O standards. Tyco Electronics continues to be engaged in new pluggable interface standards to support the rapidly changing market needs for higher bandwidth, and remains an industry leader with the technical expertise required to deliver superior designs for signal integrity and EMI at higher data rates.
FEATURES AND BENEFITS • High speed I/O solutions for copper or optical links
• Standard port design accepts Tyco Electronics Corporation, Harrisburg, PA tycoelectronics.com © 2009 Tyco Electronics Corporation. All Rights Reserved. 4-1773455-2 CIS 4M CGX 01/2010 InfiniBand is a trademark of InfiniBand Trade Association. TE (logo) and Tyco Electronics are trademarks of the Tyco Electronics group of companies and its licensors. Other products, logos, and Company names mentioned herein may be trademarks of their respective owners.
While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this catalog, Tyco Electronics does not guarantee that it is error-free, nor does Tyco Electronics make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. Tyco Electronics reserves the right to make any adjustments to the information contained herein at any time without notice. Tyco Electronics expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this catalog are for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult Tyco Electronics for the latest dimensions and design specifications.
pluggable transceivers or direct attach cable assemblies • Supports various protocols and data rates • Direct attach copper cable assemblies for lower cost
www.tycoelectronics.com/products/pluggableio
PRODUCT APPLICATIONS • Storage, networking and telecom markets
• Switches, routers, hubs • Network Interface Cards (NICs) • Ethernet, Fibre Channel, InfiniBand, SAS standards
Pluggable I/O Solutions
Pluggable I/O Solutions PLUGGABLE I/O SOLUTIONS
Riding Heat Sink Application for Thermal Management
Protocols for Pluggable I/O Interfaces Pluggable Interface Application
Data Rate SFP
Fibre Channel
1G
X
Fibre Channel
2G
X
Fibre Channel
4G
X
Fibre Channel
8G
XFP
X2
XPAK
Xenpak
SFP+
QSFP/ QSFP+
X
Ethernet
1G
Ethernet
10G
Ethernet
40G (4x10G)
Ethernet
100G (10x10G)
X X
X
X
X
X
X X
InfiniBand
2.5G
X
InfiniBand
5G
X
InfiniBand
10G
InfiniBand
20G (4x5G)
X
InfiniBand
40G (4x10g)
X
6G
X
SAS
CFP
X
Optical modules and cable
In unmated state, heat sink
X
include lasers for electrical-optical
contact surface drops into
on the plug surface, drawing heat
conversion, generating heat.
opening in cage top.
to the heat sink pins. Clip maintains load between heat sink and plug
X X
With plug inserted, heat sink rides
surfaces. Customer manages
X
airflow to dissipate heat.
Components of a Pluggable I/O Interface
Lightpipe Application Port indicators at faceplate Lightpipe clips onto the cage
Lightpipe Heat sink and Clip
Cage
Surface mount LED PT Connector Direct Attach Copper Cable
Optical Transceiver Module Optical Cable Active Optical Cable
Questions at Design In
Typical Cage Port Configurations Single Port Cages
Ganged Cages
What protocol and data rate is required?
What are your cable requirements?
• Please reference the ‘Protocols for Pluggable I/O’
• Depending on the Pluggable I/O interface, copper or optical
interface table. (on page 2) Belly-to-Belly Cage Mounting
Stacked Cages
cable assemblies and transceivers or direct attach assemblies are available. TE manufactures many different cable lengths.
Does your application have specific density requirements?
• Assemblies can be configured by the number of ports and meet your height/width restrictions.
Are there any grounding concerns?
• All cages are full metal shielded for grounding and EMI suppression.
Does the design require thermal dissipation?
• Heat sinks are available for the following protocols: XFP, SFP, SFP+, QSFP, CFP
Pluggable I/O Solutions I Tyco Electronics
www.tycoelectronics.com/products/pluggableio
www.tycoelectronics.com/products/pluggableio
Pluggable I/O Solutions I Tyco Electronics