Preview only show first 10 pages with watermark. For full document please download

Pluggable Interface Relays Technical Data

   EMBED


Share

Transcript

s lay e e r ge fac Ran r e Int CR Pluggable interface relays Technical data Type CR-P...1 Output circuit(s) Kind of output Contact material CR-P...2 CR-M...2 CR-M...3 CR-M...4 11-12/14 21-22/24 31-32/34 41-42/44 Relay, 4 c/o AgNi AgNi/Au 5 µm 11-12/14 11-12/14 21-22/24 11-12/14 21-22/24 11-12/14 21-22/24 31-32/34 Relay, 1 c/o Relay, 2 c/o AgNi AgNi/Au 5 µm Relay, 2 c/o Relay, 3 c/o AgNi AgNi AgNi Rated operational voltage Ue (VDE 0110, IEC 60947-1) 11-12/14 31-32/34 11-12/14 21-22/24 31-32/34 Relay, 2 c/o Relay, 3 c/o AgNi 5V Maximum switching voltage DC 300 V DC AC 400 V AC 250 V DC 250 V AC Minimum switching current 5 mA (AgNi), 2 mA (AgNi/Au) Rated free air thermal current Ith Rated ­operational current (IEC 60947-5-1) AC rating (UL 508) CR-U...3 250 V Minimum switching voltage 6 CR-U...2 16 A 8A 12 A 10 A 6A 10 A AC12 (resistive) 230 V 16 A 8A 12 A 10 A 6A 10 A AC15 (inductive) 230 V 1.5 A 1A 1.5 A 1.5 A 1A 1.5 A DC12 (resistive) 24 V 16 A 8A 12 A 10 A 6A 10 A DC13 (inductive) 24 V 2A 2A 8A 8A 6A 2A Utilization category (Control Circuit Rating Code) - - - B 300 max. rated operational voltage - - - 300 V AC max. continuous thermal current at B 300 - - - 5A max. making / breaking apparent power at B 300 - - - 3600/360 VA Utilization category General Purpose (single phase) - - 10 A, 250 V AC 10 A, 250 V AC 10 A, 250 V AC - 10 A, 250 6 A, 250 V AC 6 A, 250 V AC V AC 10 A, 150 10 A, 150 12 A, 150 V V AC V AC AC 0.3 W (AgNi), 0.1 W (AgNi/Au) Utilization category (Resistive) 16 A, 250 V AC 8 A, 250 V AC AC-1 4000 VA 2000 VA Minmum switching power Maximum switching power Contact resistance Maximum switching capacity rated load AC-1 without load Mechanical lifetime Electrical lifetime AC1 (resistive) 3000 VA 2500 VA 0.3 W 1500 VA 2500 VA  100 m  100 m 600 switching cycles/h 1200 switching cycles/h 72000 switching cycles/h > 3 x 107 switching cycles > 10 5 switching cycles (16 A, 250 V) (8 A, 250 V) cos ϕ 18000 switching cycles/h 12000 switching cycles/h > 2 x 107 switching cycles > 10 5 switching cycles > 10 5 switching cycles (12 A, 250 V) (10 A, 250 V) (6 A, 250 V) (10 A, 250 V) see reduction factor F Response time typ. 7 ms typ. 13 ms (DC),10 ms (AC) typ. 18 ms (DC), 12 ms (AC) Release time typ. 3 ms typ. 3 ms (DC), 8 ms (AC) typ. 7 ms (DC), 10 ms (AC) Isolation data Rated insulation voltage 400 V AC Insulation class 250 V AC C250 / B400 Rated impulse withstand voltage Uimp between coil and contacts between open contacts C250 / B250 5 kV AC C250 2.5 kV AC 1 kV AC 1.5 kV AC between c/o contacts 2.5 kV AC 2.5 kV AC 2 kV AC 2 kV AC Clearance between coil and contacts  10 mm  2.5 mm  1.6 mm  3 mm Creepage distance between coil and contacts  10 mm  4 mm  3.2 mm  4.2 mm Overvoltage category III III II III Pollution degree 3 3 2 3 General data Dimensions (W x H x D) when mounted Weight 12.7 x 29 x 15.7 mm 21.2 x 27.5 x 35.6 mm 35 x 35 x 54.4 mm 14 g (0.031 lb) 35 g (0.077 lb) 83 g (0.18 lb) Mounting on socket (see accessories) Mounting position Degree of protection any IP 67 IP 40 Electrical connection Connection by socket Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected] Int er f CR ace Ra rela ng ys e Pluggable interface relays Technical data, load limit curves Type CR-P...1 CR-P...2 CR-M...2 CR-M...3 CR-M...4 CR-U...2 CR-U...3 Environmental data Ambient temperature range operation DC -40 ... +85 °C -40 ... +70 °C operation AC -40 ... +70 °C -40 ... +55 °C storage Vibration resistance 10-150 Hz Shock resistance -40 ... +85 °C n/o contact 10 g 5g 5g n/c contact 10 g 5g 5g 5g n/o contact 30 g 20 g 10 g 10 g n/c contact 30 g 20 g 5g 10 g EN 60810-1, EN 60255-23 IEC 61810-7 EN 60255-1-00 Standards Product standard EN 61810-1, EN 60255-23 IEC 60664-1 Low Voltage Directive 73/23/EEC CR-P with 1 c/o contact CR-P with 2 c/o contacts CR-U with 2 and 3 c/o contacts DC current [A] DC current [A] DC current [A] Load limit curves - Maximum switching power at resistive DC load 1 = resistive load, T = 0 ms 2 = inductive load, T = 40 ms DC voltage [V] DC voltage [V] DC current [A] DC voltage [V] CR-M with 4 c/o contacts 1 = resistive load, T = 0 ms 2 = inductive load, T = 40 ms DC voltage [V] DC current [A] CR-M with 3 c/o contacts DC current [A] DC voltage [V] CR-M with 2 c/o contacts DC voltage [V] Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected] 6 s lay e e r ge fac Ran r e Int CR Pluggable interface relays Load limit curves Load limit curves - Electrical lifetime at resistive AC load Switching cycles Switching cycles CR-U with 2 and 3 c/o contacts Switching power [kVA] Switching power [kVA] CR-M with 2 c/o contacts Switching power [kVA] CR-M with 4 c/o contacts Switching power [kVA] Switching cycles Switching cycles Switching cycles CR-M with 3 c/o contacts Switching power [kVA] Switching power [kVA] Reduction factor F at inductive AC load CR-M CR-U Reduction factor Reduction factor CR-P Reduction factor 6 CR-P with 2 c/o contacts Switching cycles CR-P with 1 c/o contact Power factor Power factor Power factor Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected] Pluggable interface relays Connection diagrams Int er f CR ace Ra rela ng ys e Connection diagrams 6 CR-P with 1 c/o contact CR-P with 2 c/o contacts CR-M with 2 c/o contacts CR-M with 3 c/o contacts CR-M with 4 c/o contacts Dimensional drawings CR-P CR-U with 2 c/o contacts CR-U with 3 c/o contacts Dimensions in mm CR-M with 2 c/o contacts CR-U with 2 c/o contacts CR-M with 3 c/o contacts CR-U with 3 c/o contacts Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected] s lay e e r ge fac Ran r e Int CR Pluggable interface relays Approximate dimensions Dimensional drawings Dimensions in mm Sockets for screw connection Marker Marker 42,6 27,2 62 27,2 27,2 24 51,2 15,8 7,5 Relay 35,4 75,2 29 Holder 10 6 76 20 Pluggable function module Relay CR-M2SS - CR-M3SS - CR-M4SS Holder 60,8 27,2 Marker 27,2 42,6 27,2 24 Pluggable function module 62 75 35,4 Relay CR-PLS Holder 62 61 CR-M2LS 42.5 CR-M3LS Pluggable function module 29,1 CR-M4LS 3.2 37,3 38,1 78.5 Relay 75,3 Holder 9 - M3 Pluggable function module 24 7.62 35,4 75,3 12 - M3 29.4 5.08 20.32 5.08 CR-M2LS - CR-M3LS - CR-M4LS 50 4 15.5 29,8 CR-PLSx CR-U2S 29,8 CR-U3S CR-U2S - CR-U3S Marker 42.8 76 20 10 Holder Relay CR-U3E Pluggable function module 24 15,8 CR-PSS Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected] Int er f CR ace Ra rela ng ys e Pluggable interface relays Approximate dimensions Dimensional drawings Dimensions in mm 38,1 38,1 26 27,8 27,8 8 - M3 35,4 61,8 61,8 11 - M3 6 CR-U2SM CR-U3SM 4 CR-U2SM CR-U3SM Sockets for spring connection 43,5 42,5 33,8 7,62 33,2 31 24 95 5,5 25,9 20,32 5,08 97,5 15 5,08 12,4 12,4 24,4 16,3 27 34,4 26 79,5 CR-PLC CR-M2LC , CR-M4LC Jumper 9 x 27.2 (=244,8) 27.2 ±0.2 2±0,2 6±0,2 1 R1 9,5 10 246.8 CR-PJ 9x15 (=139,5) 15,5 ±0,2 2±0,2 R1 1,5 6±0,2 10 10 141,5+1 CR-MJ Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]