Preview only show first 10 pages with watermark. For full document please download

Plx12-700ft (12v715w)

   EMBED


Share

Transcript

PLX SERIES PLX12-700FT (12V715W) HIGH RATE Specification Nominal Voltage 12V Power (Watts) 715W (15min,1.67V/cell,25o C) Rated Capacity (Ah) 190Ah (C10,1.80V/cell,25o C) PC-ABS flame retardant jar and cover to UL94V-0 Max. Discharge Current 1500A (5s) Internal Resistance Approx 3.0mΩ Operating Temp.Range Discharge : -40o C~65o C (-40o F~149o F) Charge : 0o C~40o C (32o F~104o F ) Storage : -20o C~40o C (-4o F~104o F) Capacity affected by Temperature 40o C 25o C 0o C (104o F) ( 77o F ) ( 32o F ) 320±2 309.5 Threaded M8 insert with M6 front terminal adaptor Container Material 103% 100% 86% 538.1 PLX series batteries can be stored up to 24 months at 25°C(77°F), For higher temperatures the time interval will be shorter. Battery needs to be given a freshening charge when the OCV approach 2.10V/cell or when the maximum storage time is reached, whichever occurs first. Storage 123 561.9±2 540 20 125±2 Weight Terminal 29.3±0.5 Dimension 562±2mm (22.13 inches) 125±2mm ( 4.92 inches) 320±2mm (12.60 inches) 320±2mm (12.60 inches) 2 Length Width Container Height Total Height (with Terminal) 60.5Kg (133.1 Ibs) M8 242±1 Unit: mm t est ed Germany Constant Current Discharge (Amperes) at 25 0 C (77 0 F ) F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 8h 10h 20h 1.85V/cell 399.0 338.6 296.4 254.8 192.7 142.1 112.5 64.9 46.8 36.8 30.7 21.4 18.4 9.58 1.80V/cell 458.3 378.5 330.6 281.6 207.9 151.2 118.8 67.2 48.6 38.0 31.7 22.1 19.0 9.88 1.75V/cell 499.3 408.1 351.9 300.4 220.8 158.8 124.5 68.7 49.6 39.0 32.5 22.5 19.3 10.1 1.70V/cell 547.2 437.2 370.1 313.5 231.4 165.7 128.6 70.5 50.7 39.8 33.1 22.9 19.5 10.2 1.67V/cell 655.0 462.8 382.1 326.0 239.6 171.0 133.0 71.8 51.3 40.1 33.5 23.3 19.6 10.3 1.60V/cell 670.1 487.9 398.5 334.6 246.8 175.8 136.0 73.0 51.6 40.5 33.8 23.4 19.8 10.4 0 0 Constant Power Discharge (Watts/cell) at 25 C (77 F ) F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 8h 10h 20h 1.85V/cell 742.9 645.3 572.3 495.9 377.6 281.1 223.2 129.6 93.7 73.9 61.8 43.5 37.4 19.5 1.80V/cell 846.0 713.4 635.1 544.5 404.8 297.0 234.1 133.4 96.8 76.0 63.6 44.5 38.5 20.1 1.75V/cell 913.5 764.0 671.7 575.5 426.3 309.7 243.7 135.8 98.4 77.5 64.8 45.3 39.0 20.4 1.70V/cell 975.1 805.8 699.6 595.0 443.3 321.0 250.5 138.8 100.2 78.9 65.8 46.1 39.3 20.6 1.67V/cell 1000.0 825.2 715.0 612.4 460.0 329.5 257.5 140.7 101.0 79.3 66.5 46.6 39.4 20.7 1.60V/cell 1060.0 842.6 720.0 621.6 475.0 335.4 261.3 142.0 101.0 79.7 66.8 46.7 39.7 20.8 Specifications subject to change without notice. Features & Benefits 15 years design life(25°C) Automated COS & TTP Excellent high rate discharge capability Low internal resistance M6 & M8 Terminal adapter options for emergency backup power supply Fast Charging Acceptance Flame Retardant to UL94V-0 particularly UPS. High quality AGM separators minimize Premium ABS+ jar & covers Long Shelf Life up to 2 years @77°F(25°C) IATA Approved for Air Freight High-rate performance, high energy density Heat sealed plastic container Virgin pure lead plates / copper alloy UL Recognized, IEC Certified terminal inserts with Thin Plate Pure Lead technology Charging Charging Voltage Current Charging Volume Temperature 25 o C (V) Terminal Voltage(V) Outstanding high rate charge capability Charging Characteristics Discharging Characteristics 12V Battery electrical resistance to allow high current discharging properties. (%) (XCA) 140 13 12 120 0.10 100 0.08 13.5V Temperature 25oC (V) Charged Volume 15 14 11 80 0.263C 10 13 60 1.064C 0.615C 9 Charge Voltage 0.06 0.1C 0.053C 0.04 40 After 50% Discharge 12 After 100% Discharge 0.02 8 3.5C 1 2 4 2.4C 6 8 10 0.1 20 20 11 Charging Current 40 60 100 200 0.2 0.3 0.4 0.5 1 400 600 1000 2000 2 3 45 10 20 (Min) 0 0 0 0 4 8 Discharging Time 1h Rate 20 24 28 32 36 40 Self Discharge Characteristics 5h Rate Temperature 25oC 10 100 Remaining Capacity C10(%) Discharging Time (h) 16 Charging Time(hours) Effect of Temperature on Discharging Time 15min Rate 12 (Hours) 1 0.1 0.01 -40 -30 -20 -10 0 10 20 30 25 o C 90 o 80 70 60 50 40 30 40 o 45 C 55 C 0 o Temperature( C) 10 20 30 40 50 60 70 Storage Time (Weeks) Pure Lead Battery General AGM Battery China sales office HongKong sales office Singapore sales office Australia Sales Office 5th Floor,Xinbaohui Bldg.,Nanhai Blvd., Nanshan,Shenzhen, China. 518052 Tel: +86-755-86036060 (100 lines) Fax: +86-755-26067269 E-mail:[email protected] Workshop C, 33/F, TML Tower,No. 3 Hoi Shing Road, Tsuen Wan, New Territories, Hong Kong Tel: +852 35786666 Fax:+44 1452 690125 [email protected] No. 1 Tech Park Crescent, Singapore 638131 Tel: +65 68636078 2 /29 Tarlington Place, Smithfield. NSW 2164 Australia Tel: 02 9756 0950 E-mail: [email protected] Email [email protected] North America sales office UK sales office Europe/MEA Sales Office India Sales Office 19751 Descartes, Unit A, Foothill Ranch, CA 92610, USA Tel: 949-588-5853 9B Wheatstone Court. Waterwells, Business Park, Gloucester, GL2-2AQ, UK United Kingdom Tel: +44(0) 1452 729428 / 1452 729696 1 Deligiorgi St., 121 31 Athens Greece Tel: +30 210 5760318 (2 lines) Fax: 949-588-5966 Fax:+44 1452 690125 E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] Shed no.A-53(b), 2nd Stage of Peenya Industrial Area, Bangalore North Taluk, Bangalore-560058, India Tel: +91-80-23440018/23440019 Fax: +91-80-23440017 E-mail: [email protected] Http://www.leoch.com Fax: +65 6863 6079 © 2017 LEOCH. All rights reserved. Trademarks and logos are the property of LEOCH and its affiliates unless otherwise noted. Http://www.leoch.us Subject to revisions without prior notice. Publication No.:LB-PLX12-700FT-PD-EN-V1.0-201708 Sales Offices Worldwide