Transcript
PM500-series 260 to 500 W INPUT / OUTPUT
OPERATION
• • • • •
• • • •
Optimized input voltage ranges Input ranges from 50 to 300 Vd.c. Single outputs from 13.2 to 110 Vd.c. Reverse input voltage protection Input EN 50155 / IEC 60571
Operating temperature range -25 to +70 °C. High efficiency. Fully encapsulated, meets IP20 as standard. Convection cooled.
EMC FEATURES • • • •
Overvoltage protection OVP Extra output with series diode Over/Under voltage alarm with relay output Output voltage adjustable from outside
• • • • • •
EN/IEC 61000-6-3, Emission. EN/IEC 61000-6-2, Immunity. EN/IEC 61000-4-4, 4 kV. EN/IEC 61000-4-5 level 2 & 3. EN60950-1 RoHS directive
OUTPUT
INPUT Nominal inputs 110, 127 Vd.c.
Input range 93-150 V
Stop level < 77 Vd.c.
Voltage
Current
110
13.2 V
20.0 A
260 W
20.0 A
500 W
Code
Power
72, 96, 110, 127 Vd.c.
50-150 V
< 50 Vd.c.
110C
24 V
220, 250 Vd.c.
187-300 V
< 154 Vd.c.
220
48 V
10.5 A
500 W
110, 127, 220, 250 Vd.c.
100-300 V
< 100 Vd.c.
220D
110 V
4.5 A
500 W
OUTPUT RATING & TYPE CODE OUTPUT
INPUT
Voltage
Current
Power
13.2 V
20.0 A
260 W
50 - 150 V
93 - 150 V
100 - 300 V
24 V
20.0 A
500 W
PM500 110/24
PM500 220/24
1
PM500 220T/282
PM260 110C/13.2
187 - 300 V
PM260 220D/13.2
28 V
15.0 A
420 W
PM500 110T/28
48 V
10.5 A
500 W
PM500 110/48
PM500 220/48
110 V
4.5 A
500 W
PM500 110/110
PM500 220/110
Train Inputs
How to read our product code: Example PM500 110/24
1) 110T = 77 - 150 Vdc
PM500 = Family code
2) 220T = 154 - 300 Vdc
110 = input voltage code 110 24 = Output voltage 24V
FEATURES
OPTIONAL FEATURES
Overvoltage protection OVP
Conformally coating, option I
The output voltage is limited to 15 % over nominal output voltage by an extra regulation circuit.
For environment with high non condensing humidity max 98 % RH.
Extra output with series diode
+70 °C operating temperature
Use the series diode output when the output is connected in parallel with other power supplies to achieve redundancy.
Contact factory for derating as it depends on model.
Over / Under voltage alarm
Mounting brackets L58-1
The built in relay changes to alarm state if the converter output voltage is not within 90 to 115 % of nominal output. The user can select NO or NC relay function. The relay rating is 30 V 0.5 A (d.c. or a.c.), for higher voltage please contact Polyamp.
Se figure 4.
Inrush current limit
19” frontpanel 2U for one unit
Reduce the inrush current during start up. the input voltage range will be affected.
Over temperature shutdown protection The unit switch-off and restart with hysteresis. Red LED indication and alarm.
Operating temperature range The PM500 series is rated to +55°C @ 100% load and continuous operation. However PM500 is designed for operation up to +70°C with derating. Temporary temperature rise e.g. as described in EN50155 T3 up to +85°C can be accepted as the cooling sysem has a thermal inertia. -40°C is optional as we need to test each batch.
Mounting brackets L214-2 Se figure 4.
19” frontpanel 2U for two units To mount two PM500 together to form a full 19” rack unit, see figure 3.
To mount one PM500 to form a full 19” rack unit, see figure 3.
DIN-rail mounted Using DIN-Rail holder, see figure 4
EN/IEC 61000-4-5 level 4 External varistor + surge arrestor mounted from pole to ground. With this filter the input meets level 4 of EN/IEC 61000-4-5 (+/-2 kV line to line, 4 kV line to ground)
Train input Input voltage range according to train standard EN 50155 and IEC 60571, see train T-inputs page 3.
GENERAL DATA / INPUT DATA
OUTPUT DATA
LABEL
VALUE
LABEL
VALUE
Design topology
Push-Pull
Source regulation
0.1 %
Switching frequency
200 kHz
Load regulation (0 to 100 % load)
< 0.2 V
Emission / Immunity
See page 4
Transient recovery time for 10 to 90 % load step to within 3 % of nominal output voltage.
< 3 ms
Output ripple (200 kHz) 3
30 mV p-p
Input ripple attenuation to output (50 to 400 Hz)
500:1 or -54 dB
Emission / Immunity
See page 4
Temperature coefficient
0.02 % / °C
Min output adjustment range adjustable with a 15 turn potentiometer
95 - 110 % 105 %
Safety EN/IEC 60950
Class I 1
Max. accepted input ripple 0-400 Hz
2 % of nom. voltage
Input power at no load
Typ 10 W
Reverse input voltage protection
In start up sequence2
Vibration and shock EN/IEC 61373 Body mounted
Class B
IEC 60721-3-5 Ground vehicle installation
Class 5M2
IEC 60068-2-27: 2008 Bump
30 g 6 ms
IEC 60068-2-64: 2008 Random vibration
1.68 gRMS
FIRE PROTECTION EN 45545-2
“Non listed product” 4.2.2. < 100 g
Current limit, rectangular Remote sense
No
Dimensions (D x W x H)
194 x 214 x 58 mm
Soft start
Yes
Weight
2.4 kg
Start-up time
<1s
Hold-up time, contact factory
2 - 25 ms
Efficiency4
> 88 %
Operating temperature range at 100 % load. (Convection cooling) with derating5
-25 to +55 °C +70 °C
Storage temperature range
-40 to +85 °C
1. Higher ripple affects the input, contact factory 2.The converter does not start reverse voltage.
OPTIONAL T-INPUTS DC INPUTS MOBILE Uin 0.1s-S2
Continous range
Code
66 - 154 Vd.c
77 - 150 Vd.c.
110T
132 - 308 Vd.c.
154 - 300 Vd.c.
220T
Input voltage range according to train standard EN 50155 and IEC 60571
3. The output ripple might increase to 1 % RMS of Vout, when EN/IEC 61000-4-3, 20V/m test is applied. 4. Lowest efficiency measured within the whole input voltage range at 100 % load. 5. Contact factory for derating as it depends on model.
MECHANICAL DRAWING PM500 R wall mounted, brackets L58-1 Option 400065
PM500 Standard for wall- or DIN mounting
Figure 1. Dimensions 19” front panel 2 U for two units, Option 400062 + handles 400066
19” front panel 2 U for two units with blind panel. Option 400062 + Blind panel 400067 + handles 400066
19” front panel 6 U for five units, brackets L480-3 and PL58-1 Option 400063 + handles 400066
19” front panel 6 U for five units with blind panle. Option 400063 + Blind panel 400067 + handles 400066
Figure 2. 19”-rack mounting PM500 R
Weight: 2.4 kg
PM500 DIN-rail mounted. Standard DIN-rail mounted TS35 clips
PM500 R DIN rail mounted, brackets L58-1 + TS35 clips Option 400065
PM500 R DIN rail mounted, bracket L58-2 + TS35 mounting plate Option 400064 Figure 4. Wall, chassis & DIN mounting
SAFETY AND EMC
SAFETY STANDARD EN/IEC 60950
PM500 meets the requirements defined by CE mark as apparatus.
ISOLATION TESTABLE LEVELS
PM500 meets requirements of EMC directive and low voltage directive (LVD).
Input / Alarm
Input / Output
Input / Case
Thus a PM500 can be used as free standing unit or in installations as well as systems designed according to ”The modular approach”. PM500 can be used in installation without further EMC tests, if our installation instructions are followed.
TEST VOLTAGE 3 kVa.c. / 4.3 kVd.c. 3 kVa.c. / 4.3 kVd.c. 2.5 kVa.c. / 3.6 kVd.c.
Output / Case all outputs
2.5 kVd.c.
Output / Alarm
2.5 kVd.c.
Case / Alarm
2.5 kVd.c.
We use the product standard Low voltage power supplies, DC outputs EN/IEC 61204-3 and the generic EMC standards: EN/IEC 61000-6-1 (Immunity) EN/IEC 61000-6-2 (Immunity) EN/IEC 61000-6-3 (Emission) EN/IEC 61000-6-4 (Emission)
Please note that product standards can demand different levels or other basic standard tests. We test according to levels below. For higher levels or other tests, contact factory.
EMC EMC-STANDARDS
EMC-PERFORMANCE
Emission standards
Input
EN 55016 / CISPR16 (0.15-30 MHz)
Output
OK
OK
EN 55016 / CISPR16 (30-1000 MHz)
Immunity standards
OK
EN/IEC 61000-6-2 8 kV / 8 kV
EN/IEC 61000-4-3
20 V/m AM-Modulated
EN/IEC 61000-4-5, EN 50121-4 EN/IEC 50121-3-2 EN/IEC 61000-4-6
opt. EN 55022 level B Enclosure test
EN/IEC 61000-4-2
EN/IEC 61000-4-4
Remarks
Contact / air, Enclosure test
± 4 kV
± 4 kV
± 1 kV / ± 2 kV ± 1 kV / ± 2 kV
± 1 kV / ± 2 kV ± 1 kV / ± 2 kV
10 V RMS
10 V RMS
Output ripple can increase to 1 % of Vout Enclosure test Line-line 2 / Line-case 12 Line-line 42 / Line-case 42 AM-Modulated
EN/IEC 61000-4-8
Not sensitive
Enclosure test
EN/IEC 61000-4-10
Not sensitive
Enclosure test
Distributor
Polyamp AB 7067-14
PM500 DC-DC Converters