Pm812 Quick Installation Guide

   EMBED


Share

Transcript

PM812 Quick Installation Guide 1. Introduction Industrial Managed Ethernet Extender DIP Switch The PM812 includes PM812C and PM812R. PM812C(Transmitter) : This is a Power Transmitter. Data and power can be delivered at the same time through one pair Twist(copper) wire or coaxial cable to turn on and communicate with PM812R(Receiver) via RJ-11 phone jack, 2-pin Terminal Block or F-connector interface. PM812R(Receiver) : This is a Power Receiver. PM812R (Receiver) can be powered either by PM812C(Transmitter) through one pair Twist(copper) wire, coaxial cable or power supply. The Ethernet port supports IEEE802.3at PoE/PSE for fulfilling PoE/PD application. 2. Product Overview Front & Rear Panel Top Panel PM812C PM812R Mode Prof Prof 2 SNR PoC Line Mode Prof Prof 2 SNR Output Line Up(ON) Slave 17a Sym 6dB ON Coax Up(ON) Slave 17a Sym 6dB DC Coax Down Master 30a Asym 9dB OFF Twist Down Master 30a Asym 9dB PoE Twist Package Contents Industrial Managed Ethernet Extender(including PM812C and PM812R) Din Rail Kit x 2pcs Wall Mount Kit x 2pcs User’s Manual CD QIG 3. Installation Step 1 : Ensure all power sources are disconnected from PM812C and PM812R. Step 2 : To pair the PM812C and PM812R, set one to Master and the other to Slave mode on DIP Switch. Step 3 : Set PM812C and PM812R’s Prof, Prof 2, and SNR DIP switch to the same position (Default is Down position). Step 4 : Please refer to the diagram architecture to connect the devices. PM812C PM812C Front PM812C/R Rear PM812R Front PM812R LED Indicators ON ON Power 1/2/3 on PoC on PM812C only PoE Green ON PoE on PM812R only ON A valid Ethernet connection established Slow Flashing ON Data transmission or receiving A valid Ethernet connection established Green Status Remark Green Green Ethernet Color Indication LEDs Power 1/2/3 PoC Green Fast Flashing A valid Ethernet connection detected Link Rate 100 Green Slow Flashing ON Link Rate 75 Link Rate 50 Green Green ON ON Data transmission or receiving Link Data rate is 100 Mbps Link Data rate is more than or equal to 75 Mbps Link Rate 25 Green Green ON Link Data rate is more than or equal to 25 Mbps Watt 30 ON Watt 15 Watt 5 Green Green ON ON Max 30W Watt supplied More than or equal 15W Watt supplied Link Link Data rate is more than or equal to 50 Mbps More than or equal 5W Watt supplied Step 8 : Wait for minutes, once the connection is established, start to use the network services and configure software settings. Data flow from Master to Slave is designated as downstream while upstream is defined as data flow from Slave to Master. 4. Configure Software Settings Step 1 : Connect the device power, and wait 2-3 minutes for device ready. Step 2 : Connect PC/NB to ETH port with RJ-45 cable. Step 3 : Open browser (ex. IE) and type in default IP address. PM812C default IP : http://192.168.1.1 PM812R default IP : http://192.168.1.2 From Master to Slave PM812R only PM812R only PM812R only Watt LEDs are only for reference, actual power output watt will depend on link distance and quality. The reference performance is tested on 24AWG telephone wire. 1 Step 5 : Set PM812C and PM812R Line DIP switch to Coax or Twist. Step 6 : Set PM812C PoC DIP switch to ON (Up position). Step 7 : Connect the recommended power source to PM812C. DC Terminal Block Power Input : 2.5A @ DC 48V Power(Peak Current 3.75A) DC Jack Power Input : 2.5A @ DC 48V Power(Peak Current 3.75A) Step 4 : Enter the default username, password (admin/ admin), and then press . Step 5 : View the device information or configure the setting. More information, please refer to user manual. 53IT-00000138 2 V1.0