Preview only show first 10 pages with watermark. For full document please download

Pmfy-p-vbm-e Databook

   EMBED


Share

Transcript

Artwork (1-1 to 1-62):Artwork 21/08/2009 14:31 Page 59 Ceiling cassette R410A Data G6 PMFY-P-VBM-E 1. SPECIFICATIONS 1 - 56 2. EXTERNAL DIMENSIONS 1 - 57 3. CENTER OF GRAVITY 1 - 58 4. ELECTRICAL WIRING DIAGRAMS 1 - 59 5. SOUND LEVELS 5-1. Sound levels 5-2. NC curve 1 - 60 1 - 60 6. TEMPERATURE/AIRFLOW DISTRIBUTIONS 6-1. Temperature distributions 6-2. Airflow distributions 1 - 61 1 - 61 INDOOR UNITS 1 - 55 Artwork (1-1 to 1-62):Artwork 21/08/2009 14:31 Page 60 1. SPECIFICATIONS R410A Data Model PMFY-P20VBM-E Power source Cooling capacity (Nominal) 1 1 1 4 Power input Heating capacity (Nominal ) 4 Current input 2 3 3 4 Power input 3 4 Current input External finish External dimension H x W x D PMFY Net weight Decoration panel Heat exchanger FAN Model External finish Dimension HxWxD Net Weight Type x Quantity External static press. Motor type Motor output Driving mechanism Airflow rate (Low-Mid-High) mm in. kg (lb) PMP-40BM mm in. kg (lb) Pa mmH2O kW m3 / min L/s cfm dB Sound pressure level (Low-Mid-High) 4 (measured in anechoic room) Insulation material Air filter Protection device Refrigerant control device Connectable outdoor unit Liquid Diameter of (R410A) mm (in.) refrigerant pipe (R22, R407C) Gas (R410A) mm (in.) (R22, R407C) Field drain pipe size mm (in.) External Drawing Wiring Refrigerant cycle Document Standard Accessory attachment Remark 2.2 1,900 7,500 2,000 0.042 0.20 2.5 2,200 8,500 0.042 0.20 kW kcal / h Btu / h kcal / h kW A kW kcal / h Btu / h kW A 6.5 - 7.2 - 8.0 - 8.7 108 - 120 - 133 - 145 230 - 254 - 283 - 307 27 - 30 - 33 - 35 ø6.35 (ø1/4) Flare ø6.35 (ø1/4) Flare ø12.7 (ø1/2) Flare ø12.7 (ø1/2) Flare PMFY-P25VBM-E PMFY-P32VBM-E 1-phase 220-240V 50Hz, 1-phase 220V 60Hz 3.6 2.8 3,100 2,400 12,300 9,600 3,150 2,500 0.044 0.044 0.21 0.21 4.0 3.2 3,400 2,800 13,600 10,900 0.044 0.044 0.21 0.21 Galvanized, with grey insulation sheet 230 x 812 x 395 9-1/16 x 32 x 15-9/16 14 (31) PMP-40BM PMP-40BM MUNSELL (0.98Y 8.99/0.63) 30 x 1,000 x 470 1-3/16 x 39-3/8 x 18-9/16 3 (7) Cross fin (Aluminum fin and copper tube) Line flow fan x 1 0 0 1-phase induction motor 0.028 Direct-driven by motor 7.3 - 8.0 - 8.6 - 9.3 7.3 - 8.0 - 8.6 - 9.3 122 - 133 - 143 - 155 122 - 133 - 143 - 155 258 - 283 - 304 - 328 258 - 283 - 304 - 328 32 - 34 - 36 - 37 32 - 34 - 36 - 37 Polyester sheet PP honeycomb fabric Fuse LEV R410A, R407C, R22 CITY MULTI ø6.35 (ø1/4) Flare ø6.35 (ø1/4) Flare ø6.35 (ø1/4) Flare ø6.35 (ø1/4) Flare ø12.7 (ø1/2) Flare ø12.7 (ø1/2) Flare ø12.7 (ø1/2) Flare ø12.7 (ø1/2) Flare O.D. 26 (1) IU-BH01-C184 IU-RG79-A671 G6 PMFY-P40VBM-E 4.5 3,900 15,400 4,000 0.054 0.26 5.0 4,300 17,100 0.054 0.26 PMP-40BM 7.7 - 8.7 - 9.7 - 10.7 128 - 145 - 162 - 178 272 - 307 - 343 - 378 33 - 35 - 37 - 39 ø6.35 (ø1/4) Flare ø6.35 (ø1/4) Flare ø12.7 (ø1/2) Flare ø12.7 (ø1/2) Flare Installation Manual, Instruction Book Drain hose I.D. 26 (1) (flexible joint) Optional parts Decoration panel PMP-40BM PMP-40BM PMP-40BM PMP-40BM *PMFY-P-VBM-E should used together with PMP-40BM Installation Note : Indoor : Outdoor : Pipe length : Level difference : Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual. 1 Nominal cooling conditions 27˚CDB/19˚CWB (81˚FDB/66˚FWB) 35˚CDB (95˚FDB) 7.5 m (24-9/16 ft) 0 m (0 ft) 2 Nominal cooling conditions 27˚CDB/19.5˚CWB (81˚FDB/67˚FWB) 35˚CDB (95˚FDB) 5 m (16-3/8 ft) 0 m (0 ft) * Nominal conditions 1, 3 are subject to JIS B8615-1. * Due to continuing improvement, above specification may be subject to change without notice. 4 The values are measured at the rated external static pressure. 3 Nominal heating conditions 20˚CDB (68˚FDB) 7˚CDB/6˚CWB (45˚FDB/43˚FWB) 7.5 m (24-9/16 ft) 0 m (0 ft) Unit converter kcal/h Btu/h cfm lb = kW x 860 = kW x 3,412 = m3/min x 35.31 = kg / 0.4536 *Above specification data is subject to rounding variation. Ref.: Spec_PMFY-P20VBM-E INDOOR UNITS 1 - 56 Refrigerant pipe(liquid) OD ø6.35 (96) 141 Ceiling Drain pan panel Same line Left side Ceiling panel 176 Refrigerant pipe(gas) OD ø12.7 395 302 254 96 outer side of grille 470 20 suspension bolt pitch 340 ceiling opening 430 43 46 Lower view 200 Front ( 56) ø50 200 Panel(grille):PMP-40BM 600 759 812 Drain pan Air outlet(lower) 1000 outer side of grille Drain pipe PVC pipe: O.D. 26 (1") 20 198 (10) 17.5 17.5 28 28 45 45 230 (20) Outer line of grille 53 30 Electrical box Center of unit 20 247 69 74.5 26 40 60 20 74.5 26 Gas pipe Liquid pipe pipe cover PVC pipe: O.D. 26 (1") OD ø12.7(1/2") OD ø6.35(1/4") OD ø43 Panel(grille):PMP-40BM Suspension bolt(M10 or W3/8) Installation space required around indoor unit Terminal block for transmission Right side Terminal block for power supply Knock out 250 Detail drawing of fresh air intake hole Fresh air intake hole 288.5 ø100 4-ø2.8 Burring hole * Drain hose I.D. 26 (1") flexible joint ······· Accessory 1pc. Drain pipe Refrigerant piping 235 or more 1000 outer side of grille 960 ceiling opening 811 suspension bolt pitch 759 20 outer side of grille 470 INDOOR UNITS 110 22 230 ø1 108 Mounting plate 110 20 2. EXTERNAL DIMENSIONS PMFY-P20,25,32,40VBM-E PMFY Top Artwork (1-1 to 1-62):Artwork 21/08/2009 14:31 Page 61 R410A Data G6 Drw. : IU-BH01-C184 Unit : mm 1 - 57 Artwork (1-1 to 1-62):Artwork 21/08/2009 14:31 Page 62 3. CENTER OF GRAVITY R410A Data G6 PMFY-P20,25,32,40VBM-E Pipe side A A: Center of gravity (mm)[in] X 165 [6-1/2] 165 [6-1/2] 165 [6-1/2] 165 [6-1/2] Y 390 [15-3/8] 390 [15-3/8] 390 [15-3/8] 390 [15-3/8] Z 130 [5-1/8] 130 [5-1/8] 130 [5-1/8] 130 [5-1/8] PMFY Model name PMFY-P20VBM-E PMFY-P25VBM-E PMFY-P32VBM-E PMFY-P40VBM-E INDOOR UNITS 1 - 58 Artwork (1-1 to 1-62):Artwork 21/08/2009 14:31 Page 63 4. ELECTRICAL WIRING DIAGRAMS R410A Data PMFY-P20,25,32,40VBM-E Drw. : IU-RG79-A671 FUSE BREAKER PULL BOX (15A) (15A) POWER SUPPLY TO NEXT ~/N 220-230-240V 50Hz INDOOR UNIT 220V 60Hz TB5 M1 M2 (SHIELD) MF PE LED1 BLU DP BLU CND (RED) POWER CNP (YLW) D.U.M *See fig: 1 ON OFF A.B (RED) ADDRESS CN43 SW1 1 2 3 4 5 6 7 8 9 10 SW12 SW11 O 0 3RD. 2ND. 1ST. DIGIT DIGIT DIGIT 4 3 2 1 (RED) ADDRESS SWC0 SW14 CN82 0 CONNECTION No. NAME SYMBOL I.B INDOOR CONTROLLER BOARD HUMIDIFIER CN25 DAMPER CN27 REMOTE SWITCH CN32 CONNECTOR HA TERMINAL-A CN41 CENTRALLY CONTROL CN51 REMOTE INDICATION CN52 CAPACITY CODE SW2 MODE SELECTION SW3 SWITCH MODEL SELECTION SW4 ZNR VARISTOR FUSE FUSE(6.3A/250V) AUX.RELAY DRAIN PUMP X1 TRANSFORMER T LED1 POWER SUPPLY(I.B) LED2 POWER SUPPLY(I.B) A.B CIRCUIT BOARD MODE SELECTION SW1 VOLTAGE SELECTION SW5 ADDRESS SETTING 1ST DIGIT SW11 SWITCH ADDRESS SETTING 2ND DIGIT SW12 CONNECTION NO. SW14 X1 X1 SW2 12 (WHT) REMOTE SWITCH CN32 1 3 8 7 6 5 4 3 2 1 4 CN41 (WHT) HA 1 5 CN51 (WHT) CENTRALLY CONTROL 1 CN52 5 (GRN) REMOTE INDICATION 1 T 1 3 6 4 3 9 108 (RED) ADDRESS CN42 1 2 4 1 3 2 1 DS 2 1 TH23 2 1 TH22 2 1 TH21 BLU BRN ORN YLW RED WHT 6 5 CN60 4 (WHT) LEV 3 2 1 6 5 2 1 0N 0FF 1 2 364 5 5 4 7 3 6 LEV BRN RED ORN YLW GRN CN6V 4 (GRN) VANE 3 SW4 SW3 5 2 REMOCON CN31 (WHT) DRAIN LED2 CN29 (BLK) GAS CN21 (WHT) LIQUID CN20 (RED) INTAKE 5 6 4 ZNR TB15 1 2 3 MV 4 5 2 1 2 1 CN25 2 1 (RED) ADDRESS CN81 CN27 3 1 2 3 4 5 6 7 8 4 8 SYMBOL MF MV DP DS TB2 TB5 TB15 TH21 TH22 TH23 LEV NAME FAN MOTOR VANE MOTOR DRAIN WATER LIFTING-UP MACH. DRAIN SENSOR POWER SUPPLY TERMINAL TRANSMISSION BLOCK MA-REMOTE CONTROLLER ROOM TEMPERATURE DETECTION (0˚C/15k , 25˚C/5.4k ) THERMISTOR PIPE TEMPERATURE DETECTION/LIQUID (0˚C/15k , 25˚C/5.4k ) PIPE TEMPERATURE DETECTION/GAS (0˚C/15k , 25˚C/5.4k ) LINEAR EXPANSION VALVE MODELS SW2 P20 0N 0FF P25 0N 0FF P32 0N 0FF P40 0N 0FF SW3 < 1> 6 5 0N 0FF 4 3123456 2 1789 10 6 5 0N 0FF 4 3123456 2 1789 10 6 5 0N 0FF 4 3123456 2 1789 10 123456 0N 0FF 6 789 5 104 3 2 1 NOTES: 1.At servicing for outdoor unit, always follow the wiring diagram of outdoor unit. 2.Symbol [S] of TB5 is the shield wire connection. 3.Symbols used in wiring diagram above are, :terminal block, :connector. 4.The setting of the SW2 dip switches differs in the capacity for the detail, see the table < 1>. 5.Please set the switch SW5 according to the power supply voltage. Set SW5 to 240V side when the power supply is 230 and 240 volts. When the power supply is 220 volts, set SW5 to 220V side. INDOOR UNITS 1 - 59 PMFY BLU 2 (BLU) 1 FUSE 3 1 1 2 CN3A CN2M (BLU) M-NET FAN (WHT) 1 2 3 TO MA-REMOTE CONTROLLER DC8.7-13V ORN ORN 5 I.B RED TO OUTDOOR UNIT BC CONTROLLER ME REMOTE CONTROLLER DC24-30V BLU BLU RED BLU GRN/YLW TB2 L N SW5 220V 240V G6 Artwork (1-1 to 1-62):Artwork 21/08/2009 14:31 Page 64 5. SOUND LEVELS R410A Data G6 5-1. Sound levels PMFY-P-VBM-E Sound level at anechoic room : Low-Middle2-Middle1-High Sound level dB (A) 27-30-33-35 PMFY-P20VBM-E PMFY-P25VBM-E PMFY-P32VBM-E PMFY-P40VBM-E 32-34-36-37 1.5m 33-35-37-39 Measurement location PMFY * Measured in anechoic room. 5-2. NC curves High speed Middle1 speed Middle2 speed Low speed 60 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 0 Approximate minimum audible limit on continuous noise 63 125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCIES (Hz) 8000 70 High speed Middle1 speed Middle2 speed Low speed 60 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 0 Approximate minimum audible limit on continuous noise 63 125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCIES (Hz) INDOOR UNITS 8000 PMFY-P40VBM-E External static pressure : 0Pa Power source : 220,230,240V, 50Hz / 220V, 60Hz OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20µPa 70 PMFY-P25,32VBM-E External static pressure : 0Pa Power source : 220,230,240V, 50Hz / 220V, 60Hz OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20µPa OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20µPa PMFY-P20VBM-E External static pressure : 0Pa Power source : 220,230,240V, 50Hz / 220V, 60Hz 70 High speed Middle1 speed Middle2 speed Low speed 60 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 0 Approximate minimum audible limit on continuous noise 63 125 250 500 1000 2000 4000 8000 OCTAVE BAND CENTER FREQUENCIES (Hz) 1 - 60 Artwork (1-1 to 1-62):Artwork 21/08/2009 14:31 Page 65 6. TEMPERATURE/AIRFLOW DISTRIBUTIONS 6-1. Temperature distributions Flow angle 30˚ R410A Data Flow angle 70˚ <˚C> <˚C> 2.7 2.7 19 2 2 21 23 23 25 Height Height G6 1 33 24 30 1 24 27 25 21 25 5 4 3 Floor distance 2 1 0 5 4 3 Floor distance 2 1 0 PMFY Note : These figures show typical temperature distributions in the conditions above. In the actual installation, they may differ from these figures under the influence of air temperature conditions, ceiling height, cooling/heating load,obstacles,etc. 6-2. Airflow distributions Flow angle 30˚ Flow angle 70˚ 2.7 3.0 2 1.0 3.0 2 2.0 Height Height 2.7 1 2.0 1 1.0 0.5 0.5 0.5 5 4 3 Floor distance 2 1 0 5 4 3 Floor distance 2 1 0 Note : These figures show typical airflow distributions in the conditions above. In the actual installation, they may differ from these figures under the influence of air temperature conditions, ceiling height, cooling/heating load,obstacles,etc. INDOOR UNITS 1 - 61 Artwork (1-1 to 1-62):Artwork 21/08/2009 14:31 Page 66 G6 PMFY R410A Data INDOOR UNITS 1 - 62